1558 OTuC7.pdf

BER performance on access network using centralized light sources and single mode + multi mode fiber Jaedon Kim, S. S-H. Yam*, David Gutierrez, and L. G. Kazovsky Photonics and Networking Research Laboratory, Stanford University, 058 Packard Building, Stanford, California 94305, USA [email protected] *

Department of Electrical and Computer Engineering, Queen'sUniversity, Walter Light Hall, Kingston, Ontario, K7L 3N6, Canada

Abstract: An access network using a centralized light sources (CLS) and multi mode fiber (MMF) is proposed and verified using BER measurements. Results show that we can implement CLS based PON using currently existing MMF infrastructure. 2005 Optical Society of America

OCIS codes: (060.2330) Fiber optics communications, (060.2360) Fiber optics links and subsystems, (060.4510) Optical communications, (060.4250) Networks

1. Introduction Recently, researches in the optical access network area have shown remarkable achievements since the advent of the passive optical network (PON) schemes. PON is the economic solutions allowing the service provider to share the cost of running fiber from the CO to the end users. Among the various solutions based on PON, a centralized light sources (CLS) approach has been proposed [1-3]. A CLS PON scheme has an advantage in that it can easily facilitate the wavelength management in the central office as well as reduce the cost of implementing the optical network unit (ONU) placing light sources only at the optical layer termination (OLT). Moreover, since we can assign a unique wavelength to each ONU or share a single wavelength among many ONUs’ with TDM switching and some appropriate scheduling processes, it turns out the CLS approach can accommodate smooth system upgrade from TDM-PON to WDM-PON in the future [4]. Although the CLS based optical access shows potential superiority for future access networks, field deployment is still limited by the infrastructure - the real coverage of the single mode fiber (SMF) in the local area, because most solutions assume SMF data link from OLT to ONU. While SMF shows high signal integrity in the long haul network, it is required to spend a large amount of time and cost to install SMF to the filed. On the other hand, multi mode fiber (MMF) is easy to install and it has been already installed on many campus or local area networks. Therefore, it would be better to include MMF into the optical access network. Despite the fact that the bandwidth-distance product is limited by the modal dispersion in MMF, there are several efforts to increase bandwidth-distance product. As a result, data transmission through a few kilometers at more than 1 gigabit per second is already achievable [5-7]. In this paper, we present, for the first time to our knowledge, a CLS access network including MMF. Using the physical mode confinement, the MMF link shows comparable performance to that of the SMF link. Results are verified using BER measurements. Considering the fact that the MMF is currently prevailing in the local area network, this architecture can expedite PON deployments. 2. Experiment, results and discussion As described in Figure 1, the network architecture follows the conventional frame of the CLS-based PON scheme [4]. In order to transmit a signal, a light source (distributed feedback (DFB) laser) is located at the OLT. Although the OLT supplies carrier to the all ONUs, since the incoming signal will decrease as it goes through the down stream link, we need an amplifier in the ONU to compensate power budget of the overall signal path. Therefore, each ONU has a semiconductor optical amplifier (SOA) and an intensity modulator to transmit the upstream signal. The upstream traffic passes through the same fiber link as the downstream link and arrives at the receiver in the OLT. In bi-directional transmission, it has been reported that the upstream signal can be more degraded than the downstream signal because the former is more exposed in the Rayleigh scattering [3]. Therefore, in our experiment we only investigate the worst case (upstream) due to space limitations.

1558 OTuC7.pdf

Fig. 1. Experiment set up. PC (polarization controller), MZ (Mach-Zehnder Modulator), VA (variable attenuator)

Generally, a passive splitter is located near the ONU in the PON access network. Hence, we can divide the whole data link into two segments. One is from the OLT to the splitter, and the other is from the splitter to the ONU. We place 15 km long SMF in the segment 1 and 1 km long MMF in the segment 2. The MMF has graded index and 50 µm core diameter. In order to connect to the single mode component, both ends of the MMF are core aligned and spliced with a small piece of SMF pigtailed by a conventional physical contact adaptor. Since we observe the performance of a single ONU, the passive splitter does not give a significant effect except contributing to the power budget. Therefore, we do not include the passive splitter in the experiment set up, instead using less SOA gain. Table 1 summarizes the loss of each component in the data link. Compared to an SMF of the same length, the MMF has additional 1.1 dB loss caused by the core misalignment between the SMF and the MMF connection as well as a higher order mode filtering at the interface from the MMF to the SMF connection. Table 1. Loss of components. System Component Loss (dB)

OLT Circulator 1.42

Segment 1(15km) SMF 3.1

Segment 2(1km) MMF SMF 2 0.9

Circulator 1.3

ONU PC 1

MZ 6

In order to create upstream data, the DFB laser in the OLT provides a continuous wave at 1550 nm that is remotely modulated at the ONU with NRZ coded, 2^23-1 pseudo random bit sequence (PRBS) at 1.25 Gbps through the intensity modulator. Overall power budget of the round trip signal path is 23.64 dB (before the 3 dB coupler). Therefore, we launch 2 dBm CW from the OLT and set the gain of SOA to 10 dB. The gain of SOA can be increased with the amount of the loss in the passive splitter, which depends on the number of ONUs. The received signal is coming from the isolator in the OLT and passing through optical attenuator (HP 8156A) and a power splitter. One branch of the power splitter goes into error analyzer (HP 70843A) after a SMF pigtailed commercially available photodiode, while the other is monitored by light wave multimeter (HP 8153A). As we vary the received power changing the value of optical attenuator, we measure bit-error-rate (BER) along the various received power for 3 separate cases. First, we measure a base line without fiber link, and then the measurement with SMF (15km) + MMF (1km) link is next. Replacing segment 2 with 1km long SMF, the third measurement is made. Comparing those 3 cases, we can clearly see the degree of difference caused by the MMF link. Figure 2 shows the results for 3 cases. Comparing the baseline to the case 3, there is 3 dB power penalty. Although we may ignore the effect of the chromatic dispersion for the 16 km long fiber link at 1.25 Gbps, the signal can be still affected by Rayleigh backscattering. Furthermore, there can be other noise sources, such as imperfect isolation of the circulators and noise coming from the SOA in the ONU. When we change the segment 2 to 1km long MMF, the signal can be degraded further due to the modal dispersion. However, since we launch the upstream signal with a polarization controlled, we can optimize the signal feasible to the upstream data link. With the finely tuned polarization control, we can achieve the BER performance up to 10-11 with the additional 2 dB power penalty compared to the case 3.

1558 OTuC7.pdf

The eye diagram for the case 2 at the low BER and high BER are shown in figure 3. As it can be seen in Figure 3, the top figure has a vague eye, and it becomes closed as time goes on, while we can see clear eye in the bottom. 1E-4

Back-to-Back SMF MMF

1E-5

Bit Error Rate

1E-6 1E-7 1E-8 1E-9 1E-10 1E-11 1E-12 -24

-23

-22

-21

-20

-19

-18

-17

-16

Received Power(dBm)

Fig. 2. BER measurement in the OLT

Fig. 3. Eye diagram of the signal in the SMF + MMF link. at BER of 10-5(top) and 10-11(bottom)

3. Conclusion In this paper, transmission performance in the SMF+MMF was presented using a promising access network configuration. Using core aligned connection and polarization control, we can achieve high BER performance with 2 dB more power penalty compared with the SMF link. Although a large portion of the link is still occupied by the SMF, considering the fact that the bandwidth-distance product of MMF keeps increasing these days, we can increase the length of the MMF link applying the same technique as in the previously investigated method. Therefore, the MMF can play an important role in the future optical access network. Reference [1] [2] [3] [4] [5] [6] [7]

N. J. Frigo, et al, “A wavelength-division multiplexed passive optical network with cost-shared components,” IEEE Photon. Technol. Lett., Vol. 6, no. 11, pp. 1365-1367, 1994. S. B. Tridandapani, B. Mukherjee, and G. Hallingstad, "Channel sharing in multihop WDM lightwave networks: do we need more channels?" IEEE/ACM Trans Networking. vol. 5, no. 5, Oct. 1997, pp. 71 9-27. J. Prat, C. Arellano, V. Polo, C. Bock, “Optical Network Unit Based on a Bidirectional Reflective Semiconductor Optical Amplifier for Fiber-to-the-Home Networks,” IEEE PHOTONICS TECHNOLOGY LETTERS, VOL. 17, NO. 1, Jan 2005, pp. 250-252. F.-T. An, K. S. Kim, D. Gutierrez, S. Yam, E. Hu, K. Shrikhande, and L. G. Kazovsky, “SUCCESS: A next-generation hybrid WD M/TDM optical access network architecture,” J. Lightwave Technol., vol. 22, no. 11, pp. 2557–2569, Nov. 2004. X. Zhao and F. S. Choa, “Demonstration of 10-Gb/s transmissions over 1.5-km-long multimode fiber using equalization techniques,” IEEE Photonics Technology Letters, vol. 14, no. 8, pp. 1187-1189, Aug. 2002. S. S-H. Yam, F-T. An, S. Sinha, M. E. Marhic and L. G. Kazovsky, “40 Gb/s Transmission over 140 m of 62.5 μm Multimode Fib er using Polarization-Controlled Launch”, presented at Conf. on Lasers and Electro-Optics, San Francisco, CA, May 16-20, 2004. T. Itoh, H. Fukuyama, S. Tsunashima, E. Yoshida, Y. Yamabayashi, M. Muraguchi, H. Toba and H. Sugahara, “1 km Transmission of 10 Gb/s Optical Signal over Legacy MMF using Mode-Limiting Transmission and Incoherent Light Source”, presented at Optical Fiber Commun. Conf., Anaheim, CA, March 6-11, 2005.

BER performance on access network using centralized ...

photodiode, while the other is monitored by light wave multimeter (HP 8153A). As we vary the received power changing the value of optical attenuator, we measure bit-error-rate (BER) along the various received power for 3 separate cases. First, we measure a base line without fiber link, and then the measurement with SMF ...

310KB Sizes 0 Downloads 199 Views

Recommend Documents

Modeling of Multiple Access Interference and BER ... - IEEE Xplore
bit error rate are important in simplifying the system design and deployment ..... (b) of the desired user with Ns = 4 and Tc = Tf /4 for TH-PPM. Shown example is ...

BER Performance of Decode-and-Forward Relaying ...
Nov 11, 2008 - scheme offers remarkable diversity advantage over direct transmission. In addition ... Diversity is an effective technique used in wireless com-.

(Open Access) Broiler Performance Fed on Mash vs ...
conditions and access to feed and water. During the ... (horizontal), and environmental conditions, equal treatment and service (based on "Management Guide.

BER Performance of Decode-and-Forward Relaying ...
Feb 18, 2009 - Telecommunications Department, Hochiminh University of Technology, Vietnam ... cooperative communications protocols where the relay must.

BER Performance of Decode-and-Forward Relaying ...
Nov 11, 2008 - Equal-Gain Combining over Rayleigh Fading Channels. Bao Quoc .... source broadcasts its data to the destination and N relays. At the end of ...

Effect of primary network on performance of spectrum ...
10–2. SNR, γ, dB. Fig. 2 Performance comparison for different positions of PU-Tx ... G.C. Alexandropoulos (Athens Information Technology, Athens,. Greece).

On Packet Loss Performance under Varying Network ...
the networks of Internet Service Providers (ISP)[1]. In our work we simulate an overlay network to in- vestigate the packet loss rate under certain network.

On Delay Performance Gains From Network Coding
gains in delay performance resulting from network coding relative to traditional ..... purpose, we define Mi,k[t] to be the memory bit associated with Packet-k and ...

On Delay Performance Gains From Network Coding
Massachusetts Institute of Technology. Cambridge, MA, 02139 ... use of network coding in wireless communication systems, gains in delay performance ...

Using Markov Logic Network for On-line Activity ...
is dressing up in the morning (in that case, the best action could be to provide high intensity light .... command), to ease social inclusion and to provide security reassurance by de- tecting situations of ... the home automation system transmitted

On using network attached disks as shared memory - Semantic Scholar
Permission to make digital or hard copies of all or part of this work for personal or classroom use ... executes requests to read and write blocks of data. It can be.

A Review on Neural Network Implementation Using FPGA
Implementation method with resource/speed tradeoff is proposed to handle signed ... negative value for a weight indicates an inhibitory connection while a ..... Derivative using Back Gate Effect”, VLSI Design and Test Workshop-2003, pp.

Centralized Inquiries - Bourse de Montréal
Feb 24, 2017 - All information requests must now be sent by e-mail to [email protected] or by phone: • Telephone: 514 787-6530. • Toll-free within Canada and U.S.A.: 1-800-361-5353, ext. 46530. • Toll-free from Great Britain and France: 00.800.3

InBrowser Network Performance Measurement - World Wide Web ...
Oct 29, 2012 - standalone measurement software, on the other hand, presents portability as well as ... The popularity of iOS with its lack of Flash support (Android is also not ..... download from servers that are relatively close to endusers.

Towards Reproducible Performance Studies Of Datacenter Network ...
Data Storage Institute ... codes for our simulation set- ups are publicly available at http://code.google.com/p/ntu-dsi- dcn/. ... fully functional datacenter network of 50,000 servers [5], with .... such as as higher network capacity and graceful pe

InBrowser Network Performance Measurement - World Wide Web ...
Oct 29, 2012 - provides application developers a best practice for understanding their ..... We run the experiment 10 times for each browser for a total of 1,000 ...... use a machine running Ubuntu 12.04 to host a custom HTTP server written in.

BER ARCE CV EN.pdf
blog: www.bernardarce.com email: [email protected]. phone: Spain +34 66569639, Costa Rica +506 83526884. I'm a multitasking profile, specialist in a ...

TCP Performance Simulations Using Ns2
Ns2 can be built and run both under Unix and Windows. Instructions on how to .... 3.3.3. Files and lists. In tcl, a file can be opened for reading with the command: ... node is not a router but an end system, traffic agents (TCP, UDP etc.) and traffi

Exploratory PerFormance Evaluation using dynamic ...
plete 'active' sub-models that serve, e.g., as embedded strategies that control the .... faces, their signature, and that these interfaces behave as described above ...

Toward Accurate Performance Evaluation using Hardware Counters
PMCs for performance measurement and analysis. ... interfaces include Intel's VTune software for Intel proces- sors [5], IBM's .... Therefore, we set the event-list.

Performance Testing using Jmeter.pdf
There was a problem previewing this document. Retrying... Download. Connect more apps... Try one of the apps below to open or edit this item. Performance ...

Communication from Centralized Processing ... -
Telephone: 18004252229 (Toll Free) or 080-22546500. Communication Reference ... The assessee is advised to use the software utility available on the website ... by the Deductor and the corrected data uploaded in NSDL database. Similarly ...

Toward Accurate Performance Evaluation using Hardware Counters
analysis and validation tool. Various drivers ... Performance counters or Performance Monitoring Counters. (PMCs) are ... Library (PCL) [8] and Performance Application Program- ..... best algorithm for quake which produced an estimation error.