Halogen free & Mud resistant Offshore cable NEK-606(2009) | IEC 60092-350, 353, 354, 376
TMC Co., Ltd has been pursuing innovation in technology and products for marine, oil and gas industry. For 20 years TMC has had a single-minded focus on delivering superior customer services with specialized marine and offshore cable solutions. The operational excellence of TMC is underpinned by its products with the best quality and the flexibility to meet specific requirements that makes us the world's most experienced marine and offshore cable manufacturer.
Company History 1991 Establishment of Seojin Industry Co.,Ltd.
1998 ISO 9001 Certification by LRQA (Quality)
2004 ISO 14001 Certification by LRQA (Environment & Quality) 2005 Changed the name of company to TMC Co.,Ltd.
2006 Won the 30 million USD Export Tower Award granted by the Ministry of Knowledge Economy 2006 Earned recognition by Hyundai Mipo Dockyard Co., Ltd. as one of the excellent suppliers.
2007 Won the 70 million USD Export Tower Award granted by the Ministry of Knowledge Economy 2007 Received the High quality supplier Certification from DSME 2007 Achieved Korean world-class product award 2007
2008 Won the 100 million USD Export Tower Award granted by the Ministry of Knowledge Economy 2008 OHSAS 18001 Certification by LRQA (for Health, Safety and Environment)
2009 Awarded the Q-Mark as a Silver grade for Offshore Cable supplier by Samsung Heavy Industries 2010 Awarded the Best Supplier for Offshore & Marine Cable by Ocean Rig 2010 Earned recognition by DSME as one of the excellent supplier 2011 2011
Awarded the Best Supplier for Offshore & Marine Cable by Stena Sphere KEPIC Certification by KEA (Manufacture of Class 1E cable)
2012 Won the 200 million USD Export Tower Award granted by the Ministry of Knowledge Economy
Certificates • Type Approval Certification for shipboard cables : ABS, BV, CCS, DNV, GL, KR, LR, NK and RINA • Type Approval Certification for NEK 606(2004) offshore cables : ABS, DNV and LR • Type Approval Certification by ABS for offshore cables and listed on ETL • Type Approval Certification for Passenger ships cables : ABS, DNV,LR, BV and CCS • Obtained Patent of Paint Resistant Shipboard Cables (Patent N0. 10-0627241) • Type Approval Certification for IEEE1580 Type P cables : ABS and DNV and listed on ETL • Type Approval Certification for LNG Carrier cables : ABS, DNV, LR and BV • Gost-R Certification for NEK 606(2004) offshore cables by GOSSTANDART • Type Approval Certification for Marine Optical Fiber Cables : ABS and DNV
TOTAL SOLUTION OF MARINE CABLE
Halogen free & Mud resistant Offshore cable
Code Designation Materials
Insulation
Fire resistance tape+insulation (Halogen-free)
B
Halogen-free ethylene propylene rubber - HF EPR
R
Cross-linked polyethylene XLPE
T
Thermoplastic compound (Halogen-free)
I
Halogen-free thermoset compound or EVA
U
Bedding / inner covering inner sheath
Bedding/Inner covering or taping (Halogen-free)
F
Screen (poss. with PE or PP)
Y
Armor / screen
No armour
X
Copper wire braid (Tinned or bare)
O
Bronze wire braid
B
Galvanized steel wire braid
C
Outer sheath
I
Thermoplastic compound (Halogen-free) SHF1
I
Halogen-free thermoset compound, SHF2
U
Halogen-free mud resistant thermoset compound, SHF Mud
U
Halogen-free mud resistant thermoset compound
B✽
Note. ✽QFCB cables only
Added abbreviation (i)
Individual screen
(c)
Collective screen
( i&c)
Individual & Collevtive screen
Example
0.6/1kV BFOU Voltage Fire resisting layer + insulation(HF EPR) Inner covering(HFC) Armor(Copper) Sheath(SHF2 or SHF mud)
Index
NEK 606 Cable type code Materials
Designation
Page
3.6/6kV RFOU, RFBU HV power cable
Flame retardant
6/10kV RFOU, RFBU
06 ~ 09
8.7/15kV RFOU, RFBU LV power & lighting cable
Flame retardant Fire resistance
Flame retardant Instrumentation & Communication cable
Earthing & Bonding wire VFD cable Technical information
Cable type code H/F H/F & M/R
3.6/6kV RFOU
P2
P2/P9
6/10kV RFOU
P3
P3/P10 P4/P11
0.6/1kV RU
11 ~ 14
8.7/15kV RFOU
P4
0.6/1kV RFOU, RFCU, RFBU
15 ~ 18
0.6/1kV RFOU
P1
P1/P8
0.6/1kV BU
19 ~ 22
0.6/1kV BFOU
P5
P5/P12
0.6/1kV BFOU, BFCU, BFBU
23 ~ 26
0.6/1kV RU
P18
-
250V RU(c), RU(i), RU(i&c)
28 ~ 36
0.6/1kV BU
P17
37 ~ 39
0.6/1kV UX
P15
250V RFOU(i), RFCU(i), RFBU(i)
40 ~ 42
250V RFOU(i)
S1
S1/S5
250V RFOU(i&c), RFCU(i&c), RFBU(i&c)
43 ~ 45
250V RFOU(c)
S2
S2/S6
46 ~ 54
250V BFOU(i)
S3
S3/S7
55 ~ 57
250V BFOU(c)
S4
S4/S8
58 ~ 60
250V RU(i)
S11
-
S12
-
250V RFOU(c), RFCU(c), RFBU(c)
250V BU(c), BU(i), BU(i&c) Fire resistance
Designation
250V BFOU(c) , BFCU(c) , BFBU(c) 250V BFOU(i) , BFCU(i), BFBU(i)
-
250V BFOU(i&c), BFCU(i&c), BFBU(i&c)
61 ~ 63
250V RU(c)
Flame retardant
0.6/1kV UX, FX-UX, RX
65 ~ 66
250V BU(i)
S13
-
Flame retardant
0.6/1kV(1.8/3kV) RFOU(VFD), FX-RFOU(VFD)
68 ~ 69
250V BU(c)
S14
-
Fire resistance
0.6/1kV(1.8/3kV) BFOU(VFD), FX-BFOU(VFD)
70 ~ 71
Note.
73 ~ 93
- H/F : Halogen free cable - H/F & M/R : Halogen free & Mud resistant cable
HV Power Cable
3.6/6kV RFOU, RFBU 6/10kV RFOU, RFBU 8.7/15kV RFOU, RFBU
06 ~ 09
Halogen free & Mud resistant Offshore cable
HV Power Cable
Cable Designation (P2, P3, P4, P2/P9, P3/P10, P4/P11) 3.6/6kV RFOU, RFBU 6/10kV RFOU, RFBU 8.7/15kV RFOU, RFBU
Application Standard - Design guide
: NEK-606 & IEC 60092-354
- Flame retardant
: IEC 60332-1 &
6/10kV RFOU
IEC 60332-3 Category A
- Halogen content
: IEC 60754-1, 0.5%↓
- Cold bend / impact
: CSA 22.2 No.03 (-40℃/-35℃)
- Mud resistant
: NEK-606 (Mud type only)
- Smoke light transmittance
: IEC 61034, 60%↑
- Sunlight (UV) resistant
: UL 1581
Construction Sectional view
Classification
Code
Construction detail
Conductor
- Stranded tinned annealed copper wires as per IEC 60228, Class 2
Conductor screen
- Semi-conducting layer (tape / compound)
Insulation
R
- HF EPR as per IEC 60092-351 - Non-metallic part : Semi-conducting layer (tape / compound)
Insulation screen
- Metallic part : Copper wire braid - A suitable separator tape(s) may be applied over the metallic part - Three metallic braided conductors shall be cabled - Flame retardant & non-hygroscopic fillers may be used
Cabling
- Suitable tape(s) may be applied on the cabled core - A Filler may be applied to obtain a circular Cable
Inner covering Armor Sheath Core identification Note. Flexible cable (Class5 Conductor) can be supplied
06
Offshore Cable
F
- Flame retardant halogen free thermoset compound
O
- Braid of tinned copper wire (O) / bronze wire (B) /galvanized steel wire (C)
(B,C) U
- A suitable separator tape(s) may be applied under/over the armor - SHF2 or SHF Mud as per IEC 60092-359 - Outer sheath color : Red - 3C : Off-white, Black, Red
●
HV Power Cable
• • • • •
NEK-606 (2009), IEC 60092-350, 353, 354, 376
3
EA
mm
mm
Dia of Thickness Nominal copper of dia. wire inner inner for braid covering covering mm
mm
mm
Dia. of wire for armour mm
Thickness Overall diameter of Nominal Tolersheath ance mm
mm
Conductor Resistance (at 20℃) (Max.)
Test Voltage
Cable Weight
±mm
Ω/km
V/5min.
kg/km
10
7
4.2
2.5
0.3
1.0
15.7
0.3
1.5
21.0
1.1
1.840
12.5
740
16
7
5.3
2.5
0.3
1.0
16.7
0.3
1.6
22.2
1.2
1.160
12.5
850
25
7
6.6
2.5
0.3
1.0
18.0
0.3
1.6
23.5
1.2
0.734
12.5
1,000
35
7
7.9
2.5
0.3
1.0
19.2
0.3
1.7
24.9
1.3
0.529
12.5
1,160
50
19
9.1
2.5
0.3
1.0
20.5
0.3
1.7
26.2
1.3
0.391
12.5
1,340
70
19
11.0
2.5
0.3
1.0
22.3
0.3
1.8
28.2
1.4
0.270
12.5
1,630
95
19
12.9
2.5
0.3
1.0
24.2
0.3
1.9
30.3
1.5
0.195
12.5
1,980
120
37
14.5
2.5
0.3
1.0
25.8
0.3
1.9
31.9
1.6
0.154
12.5
2,290
150
37
16.2
2.5
0.3
1.2
27.8
0.3
2.0
34.1
1.7
0.126
12.5
2,680
185
37
18.0
2.5
0.3
1.2
29.6
0.3
2.1
36.1
1.7
0.100
12.5
3,130
240
61
20.6
2.6
0.3
1.2
32.5
0.4
2.2
39.7
1.9
0.0762
12.5
3,940
300
61
23.1
2.8
0.4
1.2
35.7
0.4
2.3
43.1
2.0
0.0607
12.5
4,800
400
61
26.1
3.0
0.4
1.4
39.9
0.4
2.5
47.7
2.2
0.0475
12.5
6,050
500
61
29.2
3.2
0.4
1.4
43.0
0.4
2.6
51.0
2.3
0.0369
12.5
7,090
630
91
33.2
3.2
0.4
1.4
47.2
0.4
2.8
55.6
2.5
0.0286
12.5
8,810
10
7
4.2
2.5
0.3
1.2
31.9
0.4
2.2
39.1
1.9
1.840
12.5
2,360
16
7
5.3
2.5
0.3
1.2
34.1
0.4
2.3
41.5
2.0
1.160
12.5
2,740
25
7
6.6
2.5
0.3
1.2
36.9
0.4
2.4
44.5
2.1
0.734
12.5
3,280
35
7
7.9
2.5
0.3
1.4
39.9
0.4
2.5
47.7
2.2
0.529
12.5
3,860
50
19
9.1
2.5
0.3
1.4
42.7
0.4
2.6
50.7
2.3
0.391
12.5
4,500
70
19
11.0
2.5
0.3
1.4
46.5
0.4
2.8
54.9
2.5
0.270
12.5
5,520 6,770
95
19
12.9
2.5
0.3
1.6
51.0
0.4
2.9
59.6
2.7
0.195
12.5
120
37
14.5
2.5
0.3
1.6
54.5
0.4
3.1
63.5
2.8
0.154
12.5
7,910
150
37
16.2
2.5
0.3
1.6
57.9
0.4
3.2
67.1
3.0
0.126
12.5
9,080
185
37
18.0
2.5
0.3
1.6
61.8
0.4
3.4
71.4
3.2
0.100
12.5
10,630
240
61
20.6
2.6
0.3
1.8
68.5
0.4
3.6
78.5
3.4
0.0762
12.5
13,190
0.3
1.2
36.9
0.4
2.4
44.5
2.1
0.734
12.5
3,460
0.3
1.4
40.5
0.4
2.5
48.3
2.2
0.529
12.5
4,180
0.3
1.4
43.0
0.4
2.6
51.0
2.3
0.391
12.5
4,800
0.3
1.4
47.0
0.4
2.8
55.4
2.5
0.270
12.5
5,930
0.3
1.6
51.8
0.4
3.0
60.6
2.7
0.195
12.5
7,350
0.3
1.6
55.8
0.4
3.1
64.8
2.9
0.154
12.5
8,710
0.3
1.6
59.8
0.4
3.3
69.2
3.1
0.126
12.5
10,220
0.3
1.8
63.8
0.4
3.5
73.6
3.2
0.100
12.5
11,830
0.3
1.8
70.1
0.4
3.7
80.3
3.5
0.0762
12.5
14,540
2C
25
7
6.6
2.5
Earth
16
7
5.3
1.0
2C
35
7
7.9
2.5
Earth
25
7
6.6
1.2
2C
50
19
9.1
2.5
Earth
25
7
6.6
1.2
2C
70
19
11.0
2.5
Earth
35
7
7.9
1.2
2C
95
19
12.9
2.5
Earth
50
19
9.1
1.4
2C
120
37
14.5
2.5
Earth
70
19
11.0
1.4
2C
150
37
16.2
2.5
Earth
95
19
12.9
1.6
2C
185
37
18.0
2.5
Earth
95
19
12.9
1.6
2C
240
61
20.6
2.6
Earth
120
37
14.5
1.6
Offshore Cable
LV Power & Lighting Cable
mm2
Thickness of Insulation
Instrumentation & Communication Cable
Max. overall dia.
Earthing & Bonding wire
1
Min. No. of wires
VFD Cable
No.
Conductor Nominal Area
Technical Information
No. of Cores
HV Power Cable
3.6/6kV RFOU, 3.6/6kV RFBU
07
Halogen free & Mud resistant Offshore cable
HV Power Cable 6/10kV RFOU, 6/10kV RFBU No. of Cores
No.
1
3
Conductor Nominal Area
Min. No. of wires
Max. overall dia.
mm2
EA
mm
Thickness of Insulation
Dia of copper wire for braid
Thickness of inner covering
Nominal dia. inner covering
Dia. of wire for armour
Thickness of sheath
mm
mm
mm
mm
mm
mm
Overall diameter Nominal
Tolerance
mm
±mm
Conductor Resistance (at 20℃) (Max.)
Test Voltage
Cable Weight
Ω/km
V/5min.
kg/km
16
7
5.3
3.4
0.3
1.0
18.5
0.3
1.6
24.0
1.3
1.160
21.0
960
25
7
6.6
3.4
0.3
1.0
19.8
0.3
1.7
25.5
1.3
0.734
21.0
1,130
35
7
7.9
3.4
0.3
1.0
21.0
0.3
1.7
26.7
1.4
0.529
21.0
1,280
50
19
9.1
3.4
0.3
1.0
22.3
0.3
1.8
28.2
1.4
0.391
21.0
1,480
70
19
11.0
3.4
0.3
1.0
24.1
0.3
1.8
30.0
1.5
0.270
21.0
1,770
95
19
12.9
3.4
0.3
1.0
26.0
0.3
1.9
32.1
1.6
0.195
21.0
2,130
120
37
14.5
3.4
0.3
1.2
28.0
0.3
2.0
34.3
1.7
0.154
21.0
2,500
150
37
16.2
3.4
0.3
1.2
29.6
0.3
2.1
36.1
1.7
0.126
21.0
2,860
185
37
18.0
3.4
0.3
1.2
31.4
0.4
2.2
38.6
1.8
0.100
21.0
3,410
240
61
20.6
3.4
0.4
1.2
34.5
0.4
2.3
41.9
2.0
0.0762
21.0
4,220
300
61
23.1
3.4
0.4
1.2
36.9
0.4
2.4
44.5
2.1
0.0607
21.0
4,960
400
61
26.1
3.4
0.4
1.4
40.7
0.4
2.5
48.5
2.2
0.0475
21.0
6,140
500
61
29.2
3.4
0.4
1.4
43.4
0.4
2.6
51.4
2.4
0.0369
21.0
7,140
630
91
33.2
3.4
0.4
1.4
47.6
0.4
2.8
56.0
2.5
0.0286
21.0
8,870
16
7
5.3
3.4
0.3
1.4
38.4
0.4
2.4
46.0
2.1
1.160
21.0
3,230
25
7
6.6
3.4
0.3
1.4
41.2
0.4
2.6
49.2
2.3
0.734
21.0
3,820
35
7
7.9
3.4
0.3
1.4
43.7
0.4
2.7
51.9
2.4
0.529
21.0
4,370
50
19
9.1
3.4
0.3
1.4
46.5
0.4
2.8
54.9
2.5
0.391
21.0
5,040
70
19
11.0
3.4
0.3
1.6
50.8
0.4
2.9
59.4
2.7
0.270
21.0
6,140
95
19
12.9
3.4
0.3
1.6
54.9
0.4
3.1
63.9
2.9
0.195
21.0
7,400
120
37
14.5
3.4
0.3
1.6
58.4
0.4
3.2
67.6
3.0
0.154
21.0
8,540
150
37
16.2
3.4
0.3
1.6
61.8
0.4
3.4
71.4
3.2
0.126
21.0
9,780
185
37
18.0
3.4
0.3
1.8
66.1
0.4
3.5
75.9
3.3
0.100
21.0
11,410
240
61
20.6
3.4
0.4
1.8
72.8
0.4
3.8
83.2
3.6
0.0762
21.0
14,240
2C
25
7
6.6
3.4
0.3
1.4
41.2
0.4
2.6
49.2
2.3
0.734
21.0
4,020
Earth
16
7
5.3
1.0
2C
35
7
7.9
3.4
0.3
1.4
44.0
0.4
2.7
52.2
2.4
0.529
21.0
4,680
0.3
1.4
46.5
0.4
2.8
54.9
2.5
0.391
21.0
5,320
0.3
1.6
50.9
0.4
2.9
59.5
2.7
0.270
21.0
6,520
0.3
1.6
55.4
0.4
3.1
64.4
2.9
0.195
21.0
7,940
0.3
1.6
59.2
0.4
3.3
68.6
3.0
0.154
21.0
9,340
0.3
1.8
63.8
0.4
3.5
73.6
3.2
0.126
21.0
10,990
0.3
1.8
67.3
0.4
3.6
77.3
3.4
0.100
21.0
12,520
0.4
1.8
74.0
0.4
3.9
84.6
3.7
0.0762
21.0
15,560
Earth
25
7
6.6
1.2
2C
50
19
9.1
3.4
Earth
25
7
6.6
1.2
2C
70
19
11.0
3.4
Earth
35
7
7.9
1.2
2C
95
19
12.9
3.4
Earth
50
19
9.1
1.4
2C
120
37
14.5
3.4
Earth
70
19
11.0
1.4
2C
150
37
16.2
3.4
Earth
95
19
12.9
1.6
2C
185
37
18.0
3.4
Earth
95
19
12.9
1.6
2C
240
61
20.6
3.4
Earth
120
37
14.5
1.6
08
Offshore Cable
●
HV Power Cable
• • • • •
NEK-606 (2009), IEC 60092-350, 353, 354, 376
8.7/15kV RFOU, 8.7/15kV RFBU
mm
1
3
2C
7
6.6
mm
4.5
mm
0.3
mm
1.0
mm
22.0
Dia. of wire for armour mm
0.3
Conductor Resistance (at 20℃) (Max.)
Test Voltage
±mm
Ω/km
V/5min.
kg/km
1.4
0.734
30.5
1,300
Thickness Overall diameter of Nominal Tolersheath ance mm
1.8
mm
27.9
Cable Weight
35
7
7.9
4.5
0.3
1.0
23.2
0.3
1.8
29.1
1.5
0.529
30.5
1,460
50
19
9.1
4.5
0.3
1.0
24.5
0.3
1.9
30.6
1.5
0.391
30.5
1,660
70
19
11.0
4.5
0.3
1.0
26.3
0.3
1.9
32.4
1.6
0.270
30.5
1,960
95
19
12.9
4.5
0.3
1.2
28.6
0.3
2.0
34.9
1.7
0.195
30.5
2,370
120
37
14.5
4.5
0.3
1.2
30.2
0.4
2.1
37.2
1.8
0.154
30.5
2,810
150
37
16.2
4.5
0.3
1.2
31.8
0.4
2.2
39.0
1.9
0.126
30.5
3,180
185
37
18.0
4.5
0.3
1.2
33.6
0.4
2.2
40.8
1.9
0.100
30.5
3,630
240
61
20.6
4.5
0.4
1.2
36.7
0.4
2.4
44.3
2.1
0.0762
30.5
4,490
300
61
23.1
4.5
0.4
1.4
39.5
0.4
2.5
47.3
2.2
0.0607
30.5
5,290
400
61
26.1
4.5
0.4
1.4
42.9
0.4
2.6
50.9
2.3
0.0475
30.5
6,450
500
61
29.2
4.5
0.4
1.4
45.6
0.4
2.7
53.8
2.5
0.0369
30.5
7,460
630
91
33.2
4.5
0.4
1.6
50.2
0.4
2.9
58.8
2.7
0.0286
30.5
9,270
25
7
6.6
4.5
0.3
1.4
45.9
0.4
2.7
54.1
2.5
0.734
30.5
4,430
35
7
7.9
4.5
0.3
1.6
48.9
0.4
2.9
57.5
2.6
0.529
30.5
5,110
50
19
9.1
4.5
0.3
1.6
51.7
0.4
3.0
60.5
2.7
0.391
30.5
5,810
70
19
11.0
4.5
0.3
1.6
55.6
0.4
3.1
64.6
2.9
0.270
30.5
6,900
95
19
12.9
4.5
0.3
1.6
59.7
0.4
3.3
69.1
3.1
0.195
30.5
8,210
120
37
14.5
4.5
0.3
1.6
63.1
0.4
3.4
72.7
3.2
0.154
30.5
9,380
150
37
16.2
4.5
0.3
1.8
67.0
0.4
3.6
77.0
3.4
0.126
30.5
10,750
185
37
18.0
4.5
0.3
1.8
70.8
0.4
3.7
81.0
3.5
0.100
30.5
12,330
240
61
20.6
4.5
0.4
1.8
77.5
0.4
4.0
88.3
3.8
0.0762
30.5
15,260
25
7
6.6
4.5
0.3
1.4
45.9
0.4
2.7
54.1
2.5
0.734
30.5
4,670
0.3
1.6
48.9
0.4
2.9
57.5
2.6
0.529
30.5
5,420
0.3
1.6
51.7
0.4
3.0
60.5
2.7
0.391
30.5
6,140
0.3
1.6
55.6
0.4
3.1
64.6
2.9
0.270
30.5
7,320
0.3
1.6
59.7
0.4
3.3
69.1
3.1
0.195
30.5
8,730
0.3
1.8
63.9
0.4
3.5
73.7
3.2
0.154
30.5
10,250
0.3
1.8
68.0
0.4
3.6
78.0
3.4
0.126
30.5
11,830
0.3
1.8
71.5
0.4
3.8
81.9
3.6
0.100
30.5
13,430
0.4
1.8
78.3
0.4
4.0
89.1
3.9
0.0762
30.5
16,540
Earth
16
7
5.3
1.0
2C
35
7
7.9
4.5
Earth
25
7
6.6
1.2
2C
50
19
9.1
4.5
Earth
25
7
6.6
1.2
2C
70
19
11.0
4.5
Earth
35
7
7.9
1.2
2C
95
19
12.9
4.5
Earth
50
19
9.1
1.4
2C
120
37
14.5
4.5
Earth
70
19
11.0
1.4
2C
150
37
16.2
4.5
Earth
95
19
12.9
1.6
2C
185
37
18.0
4.5
Earth
95
19
12.9
1.6
2C
240
61
20.6
4.5
Earth
120
37
14.5
1.6
HV Power Cable
EA
25
Dia of Thickness Nominal copper of dia. wire inner inner for braid covering covering
LV Power & Lighting Cable
mm2
Thickness of Insulation
Instrumentation & Communication Cable
Max. overall dia.
Earthing & Bonding wire
Min. No. of wires
VFD Cable
No.
Conductor Nominal Area
Technical Information
No. of Cores
Offshore Cable
09
LV Power & Lighting Cable
0.6/1kV RU
11 ~ 14
0.6/1kV RFOU, RFCU, RFBU
15 ~ 18
0.6/1kV BU
19 ~ 22
0.6/1kV BFOU, BFCU, BFBU
23 ~ 26
LV Power & Lighting Cable
•
LV Power & Lighting Cable
●
• • • •
HV Power Cable
NEK-606 (2009), IEC 60092-350, 353, 354, 376
Cable Designation (P18) LV Power & Lighting Cable
0.6/1kV RU
Application Standard - Design guide
: NEK-606 & IEC 60092-353
- Flame retardant
: IEC 60332-1 & IEC 60332-3 Category A
- Halogen content
: IEC 60754-1, 0.5%↓
- Cold bend / impact
: CSA 22.2 No.03 (-40℃/-35℃)
- Mud resistant
: NEK-606 (Mud type only)
- Smoke light transmittance
: IEC 61034, 60%↑
- Sunlight (UV) resistant
: UL 1581
Instrumentation & Communication Cable
0.6/1kV RU
Sectional view
Classification
Code
Construction detail - Stranded tinned annealed copper wires as per IEC 60228, Class 2
Conductor Insulation
Earthing & Bonding wire
Construction R
- HF EPR as per IEC 60092-351 - Insulated cores shall be cabled
Cabling
- Flame retardant & non-hygroscopic fillers may be used - Suitable tape(s) may be applied on the cabled core - A Filler may be applied to obtain a circular Cable - SHF2 or SHF Mud as per IEC 60092-359 - Outer sheath color : Black No. of cores
Core identification
Without Earth core
VFD Cable
U
With Earth core
1C
Off-white or Black
-
2C
Off-white, Black
-
3C / 2C + E
Off-white, Black, Red
Off-white, Black, G/Y
4C / 3C + E
Off-white, Black, Red, Blue
Off-white, Black, Red, G/Y
5C / 4C + E
Black No. on white insulation
Off-white, Black, Red, Blue, G/Y
6C and over
Black No. on white insulation
Black No. on white insulation, G/Y
Technical Information
Sheath
Note. 1. Flexible cable (Class5 Conductor) can be supplied
2. Earth core(G/Y) : Yellow/Green(Green base color with yellow stripe)
Offshore Cable
11
Halogen free & Mud resistant Offshore cable
LV Power & Lighting Cable 0.6/1kV RU No. of Cores
No.
1
2
2C+E 2C+E 2C+E 2C+E 2C+E 2C+E 2C Earth 2C Earth 2C Earth 2C Earth 2C Earth 2C Earth 2C Earth 2C Earth 2C Earth
12
Conductor Nominal Area
Min. No. of wires
Max. overall dia.
mm2
EA
mm
1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 1.5 2.5 4 6 10 16 25 16 35 25 50 25 70 35 95 50 120 70 150 95 185 95 240 120
Offshore Cable
7 7 7 7 7 7 7 7 19 19 19 37 37 37 61 61 7 7 7 7 7 7 7 7 19 19 19 37 37 37 61 61 7 7 7 7 7 7 7 7 7 7 19 7 19 7 19 19 37 19 37 19 37 19 61 37
1.7 2.2 2.7 3.3 4.2 5.3 6.6 7.9 9.1 11.0 12.9 14.5 16.2 18.0 20.6 23.1 1.7 2.2 2.7 3.3 4.2 5.3 6.6 7.9 9.1 11.0 12.9 14.5 16.2 18.0 20.6 23.1 1.7 2.2 2.7 3.3 4.2 5.3 6.6 5.3 7.9 6.6 9.1 6.6 11.0 7.9 12.9 9.1 14.5 11.0 16.2 12.9 18.0 12.9 20.6 14.5
Thickness of Insulation
Thickness of sheath
mm
mm
1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6 1.8 2.0 2.2 2.4 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6 1.8 2.0 2.2 2.4 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.0 1.2 1.2 1.4 1.2 1.4 1.2 1.6 1.4 1.6 1.4 1.8 1.6 2.0 1.6 2.2 1.6
Overall diameter Nominal
Tolerance
mm
±mm
1.0 1.0 1.0 1.0 1.0 1.1 1.1 1.2 1.3 1.3 1.4 1.5 1.6 1.7 1.8 1.9 1.1 1.1 1.2 1.2 1.3 1.4 1.5 1.6 1.7 1.9 2.0 2.2 2.3 2.5 2.8 3.0 1.1 1.1 1.2 1.2 1.3 1.4 1.5
5.8 6.2 6.7 7.3 8.2 9.4 11.1 12.4 14.4 16.1 18.6 20.3 22.4 25.1 28.3 31.5 9.6 10.4 11.6 12.8 14.8 17.0 20.6 23.0 26.8 30.8 35.6 39.0 43.0 48.4 55.0 61.0 10.2 11.0 12.3 13.6 15.7 18.1 21.3
0.5 0.5 0.5 0.5 0.5 0.6 0.6 0.7 0.7 0.8 0.9 0.9 1.0 1.1 1.1 1.2 0.6 0.6 0.6 0.7 0.7 0.8 0.9 1.0 1.1 1.2 1.4 1.5 1.6 1.8 2.0 2.1 0.6 0.6 0.7 0.7 0.8 0.8 0.9
1.6
24.1
1.0
1.8
27.7
1.1
1.9
31.6
1.2
2.1
36.7
1.4
2.2
40.2
1.5
2.4
44.9
1.6
2.6
49.7
1.8
2.8
56.0
2.0
Conductor Resistance (at 20℃) (Max.)
Insulation Resistance (at 20℃) (Min.)
Test Voltage
Cable Weight
Ω/km
㏁-km
V/5min.
kg/km
12.2 7.56 4.70 3.110 1.840 1.160 0.734 0.529 0.391 0.270 0.195 0.154 0.126 0.100 0.0762 0.0607 12.2 7.56 4.70 3.110 1.840 1.160 0.734 0.529 0.391 0.270 0.195 0.154 0.126 0.100 0.0762 0.0607 12.2 7.56 4.70 3.110 1.840 1.160 0.734 1.160 0.529 0.734 0.391 0.734 0.270 0.529 0.195 0.391 0.154 0.270 0.126 0.195 0.100 0.195 0.0762 0.154
1,320 1,110 940 800 650 540 520 450 440 380 370 330 330 330 320 310 1,320 1,110 940 800 650 540 520 450 440 380 370 330 330 330 320 310 1,320 1,110 940 800 650 540 520 540 450 520 440 520 380 450 370 440 330 380 330 370 330 370 320 330
3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500
60 70 90 110 160 230 340 450 600 810 1,100 1,360 1,650 2,070 2,690 3,340 140 170 230 290 390 550 840 1,090 1,450 2,000 2,690 3,300 4,000 5,030 6,550 8,090 160 210 270 360 510 730 1,000 1,360 1,730 2,350 3,190 3,970 4,970 5,980 7,660
LV Power & Lighting Cable
•
●
• • • •
NEK-606 (2009), IEC 60092-350, 353, 354, 376
4
4C+E 4C+E 4C+E 4C+E 4C+E 4C+E 4C Earth 4C Earth 4C Earth 4C Earth 4C Earth 4C Earth 4C Earth 4C Earth 4C Earth
mm 1.7 2.2 2.7 3.3 4.2 5.3 6.6 7.9 9.1 11.0 12.9 14.5 16.2 18.0 20.6 23.1 1.7 2.2 2.7 3.3 4.2 5.3 6.6 5.3 7.9 6.6 9.1 6.6 11.0 7.9 12.9 9.1 14.5 11.0 16.2 12.9 18.0 12.9 20.6 14.5 1.7 2.2 2.7 3.3 4.2 5.3 6.6 7.9 9.1 11.0 12.9 14.5 16.2 18.0 20.6 23.1 1.7 2.2 2.7 3.3 4.2 5.3 6.6 5.3 7.9 6.6 9.1 6.6 11.0 7.9 12.9 9.1 14.5 11.0 16.2 12.9 18.0 12.9 20.6 14.5
Thickness of sheath
mm 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6 1.8 2.0 2.2 2.4 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.0 1.2 1.2 1.4 1.2 1.4 1.2 1.6 1.4 1.6 1.4 1.8 1.6 2.0 1.6 2.2 1.6 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6 1.8 2.0 2.2 2.4 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.0 1.2 1.2 1.4 1.2 1.4 1.2 1.6 1.4 1.6 1.4 1.8 1.6 2.0 1.6 2.2 1.6
mm 1.1 1.1 1.2 1.2 1.3 1.4 1.5 1.6 1.8 1.9 2.1 2.3 2.4 2.7 2.9 3.2 1.1 1.2 1.2 1.3 1.4 1.5 1.6
Overall diameter Nominal
mm 10.2 11.0 12.3 13.6 15.7 18.1 21.9 24.5 29.0 32.9 38.2 41.9 46.1 52.1 59.0 65.6 11.1 12.3 13.5 15.1 17.5 20.1 23.8
Tolerance ±mm 0.6 0.6 0.7 0.7 0.8 0.8 1.0 1.0 1.2 1.3 1.4 1.6 1.7 1.9 2.1 2.3 0.6 0.7 0.7 0.8 0.8 0.9 1.0
1.7
26.9
1.1
1.9
31.2
1.2
2.0
35.3
1.4
2.3
41.3
1.5
2.4
45.2
1.7
2.6
50.3
1.8
2.8
55.9
2.0
3.1
63.2
2.2
1.1 1.2 1.2 1.3 1.4 1.5 1.6 1.7 1.9 2.1 2.3 2.5 2.6 2.9 3.2 3.4 1.2 1.2 1.3 1.4 1.4 1.6 1.7
11.1 12.3 13.5 15.1 17.5 20.1 24.4 27.3 32.2 36.7 42.7 46.7 51.5 58.1 65.9 73.1 12.3 13.4 15.0 16.8 19.2 22.3 26.6
0.6 0.7 0.7 0.8 0.8 0.9 1.0 1.1 1.3 1.4 1.6 1.7 1.8 2.0 2.3 2.5 0.7 0.7 0.8 0.8 0.9 1.0 1.1
1.8
30.1
1.2
2.0
34.8
1.3
2.2
39.6
1.5
2.4
46.0
1.7
2.6
50.5
1.8
2.8
56.2
2.0
3.0
62.5
2.2
3.3
70.7
2.4
Conductor Resistance (at 20℃) (Max.) Ω/km 12.2 7.56 4.70 3.110 1.840 1.160 0.734 0.529 0.391 0.270 0.195 0.154 0.126 0.100 0.0762 0.0607 12.2 7.56 4.70 3.110 1.840 1.160 0.734 1.160 0.529 0.734 0.391 0.734 0.270 0.529 0.195 0.391 0.154 0.270 0.126 0.195 0.100 0.195 0.0762 0.154 12.2 7.56 4.70 3.110 1.840 1.160 0.734 0.529 0.391 0.270 0.195 0.154 0.126 0.100 0.0762 0.0607 12.2 7.56 4.70 3.110 1.840 1.160 0.734 1.160 0.529 0.734 0.391 0.734 0.270 0.529 0.195 0.391 0.154 0.270 0.126 0.195 0.100 0.195 0.0762 0.154
Insulation Resistance (at 20℃) (Min.) ㏁-km 1,320 1,110 940 800 650 540 520 450 440 380 370 330 330 330 320 310 1,320 1,110 940 800 650 540 520 540 450 520 440 520 380 450 370 440 330 380 330 370 330 370 320 330 1,320 1,110 940 800 650 540 520 450 440 380 370 330 330 330 320 310 1,320 1,110 940 800 650 540 520 540 450 520 440 520 380 450 370 440 330 380 330 370 330 370 320 330
Test Voltage
Cable Weight
V/5min. 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500
kg/km 160 210 270 360 510 730 1,110 1,450 1,990 2,700 3,670 4,520 5,480 6,930 8,970 11,140 200 260 340 450 650 930 1,330
LV Power & Lighting Cable
7 7 7 7 7 7 7 7 19 19 19 37 37 37 61 61 7 7 7 7 7 7 7 7 7 7 19 7 19 7 19 19 37 19 37 19 37 19 61 37 7 7 7 7 7 7 7 7 19 19 19 37 37 37 61 61 7 7 7 7 7 7 7 7 7 7 19 7 19 7 19 19 37 19 37 19 37 19 61 37
Thickness of Insulation
1,780
Instrumentation & Communication Cable
3C+E 3C+E 3C+E 3C+E 3C+E 3C+E 3C Earth 3C Earth 3C Earth 3C Earth 3C Earth 3C Earth 3C Earth 3C Earth 3C Earth
EA
Max. overall dia.
2,330 3,140 4,300 5,330 6,620 8,060 10,400
Earthing & Bonding wire
3
mm2 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 1.5 2.5 4 6 10 16 25 16 35 25 50 25 70 35 95 50 120 70 150 95 185 95 240 120 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 1.5 2.5 4 6 10 16 25 16 35 25 50 25 70 35 95 50 120 70 150 95 185 95 240 120
Min. No. of wires
200 260 340 450 650 930 1,430 1,880 2,570 3,510 4,790 5,880 7,140 9,010 11,720 14,500 240 310 420 560 790 1,150 1,670
VFD Cable
No.
Conductor
Nominal Area
2,250 2,940 4,000
Technical Information
No. of Cores
HV Power Cable
0.6/1kV RU
5,430 6,750 8,350 10,230 13,220
Offshore Cable
13
Halogen free & Mud resistant Offshore cable
LV Power & Lighting Cable 0.6/1kV RU No. of Cores
No.
5 7 9 12 14 16 19 24 27 30 37 44 5 7 9 12 14 16 19 24 27 30 37 44 5 7 9 12 14 16 19 24 27 30 37 44 5 7 9 12 14 16 19 24 27 30 37 44
14
Conductor Nominal Area
Min. No. of wires
mm2
EA
1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 4 4 4 4 4 4 4 4 4 4 4 4
Offshore Cable
Max. overall dia. mm
7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7
1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7
Thickness of Insulation
Thickness of sheath
mm
mm
1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0
1.2 1.2 1.3 1.3 1.4 1.4 1.5 1.6 1.6 1.6 1.7 1.9 1.2 1.2 1.3 1.4 1.4 1.5 1.5 1.7 1.7 1.7 1.8 2.0 1.2 1.3 1.4 1.5 1.5 1.6 1.6 1.8 1.8 1.8 1.9 2.1 1.3 1.3 1.5 1.5 1.6 1.6 1.7 1.9 1.9 2.0 2.1 2.2
Overall diameter Nominal
Tolerance
mm
±mm
11.5 12.5 14.7 16.5 17.6 18.5 19.7 23.2 23.7 24.6 26.7 30.6 12.3 13.4 15.8 18.0 18.9 20.1 21.2 25.2 25.8 26.7 29.2 33.2 13.4 14.8 17.5 19.8 20.9 22.2 23.4 27.8 28.4 29.7 32.2 36.6 15.0 16.3 19.5 21.9 23.3 24.6 26.1 31.2 31.9 33.3 36.1 40.8
0.6 0.7 0.7 0.8 0.8 0.9 0.9 1.0 1.0 1.0 1.1 1.2 0.7 0.7 0.8 0.8 0.9 0.9 0.9 1.1 1.1 1.1 1.2 1.3 0.7 0.7 0.8 0.9 0.9 1.0 1.0 1.1 1.2 1.2 1.3 1.4 0.8 0.8 0.9 1.0 1.0 1.0 1.1 1.2 1.3 1.3 1.4 1.5
Conductor Resistance (at 20℃) (Max.)
Insulation Resistance (at 20℃) (Min.)
Test Voltage
Cable Weight
Ω/km
㏁-km
V/5min.
kg/km
18.2 18.2 18.2 18.2 18.2 18.2 18.2 18.2 18.2 18.2 18.2 18.2 12.2 12.2 12.2 12.2 12.2 12.2 12.2 12.2 12.2 12.2 12.2 12.2 7.56 7.56 7.56 7.56 7.56 7.56 7.56 7.56 7.56 7.56 7.56 7.56 4.70 4.70 4.70 4.70 4.70 4.70 4.70 4.70 4.70 4.70 4.70 4.70
1,490 1,490 1,490 1,490 1,490 1,490 1,490 1,490 1,490 1,490 1,490 1,490 1,320 1,320 1,320 1,320 1,320 1,320 1,320 1,320 1,320 1,320 1,320 1,320 1,110 1,110 1,110 1,110 1,110 1,110 1,110 1,110 1,110 1,110 1,110 1,110 940 940 940 940 940 940 940 940 940 940 940 940
3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500
190 240 310 390 450 500 580 740 800 870 1,060 1,300 230 290 380 480 550 620 710 920 1,000 1,090 1,340 1,620 290 390 490 640 720 820 950 1,210 1,330 1,480 1,780 2,150 390 510 660 850 980 1,100 1,290 1,660 1,830 2,030 2,450 2,920
LV Power & Lighting Cable
•
●
• • • •
HV Power Cable
NEK-606 (2009), IEC 60092-350, 353, 354, 376
Cable Designation (P1, P1/P8) LV Power & Lighting Cable
0.6/1kV RFOU, RFCU, RFBU
Application Standard - Design guide
: NEK-606& IEC 60092-353
- Flame retardant
: IEC 60332-1 & IEC 60332-3 Category A
- Halogen content
: IEC 60754-1, 0.5%↓
- Cold bend / impact
: CSA 22.2 No.03 (-40℃/-35℃)
- Mud resistant
: NEK-606 (Mud type only)
- Smoke light transmittance
: IEC 61034, 60%↑
- Sunlight (UV) resistant
: UL 1581
Instrumentation & Communication Cable
0.6/1kV RFOU
Sectional view
Classification
Code
Construction detail - Stranded tinned annealed copper wires as per IEC 60228, Class 2
Conductor Insulation
Earthing & Bonding wire
Construction R
- HF EPR as per IEC 60092-351 - Insulated cores shall be cabled
Cabling
- Flame retardant & non-hygroscopic fillers may be used - Suitable tape(s) may be applied on the cabled core - A Filler may be applied to obtain a circular Cable
Sheath
- Flame retardant halogen free thermoset compound
O
- Braid of tinned copper wire (O) / bronze wire (B) /galvanized steel wire (C)
(B,C) U
- A suitable separator tape(s) may be applied under/over the armor - SHF2 or SHF Mud as per IEC 60092-359 - Outer sheath color : Black No. of cores
Core identification
VFD Cable
Armor
F
Without Earth core
With Earth core
1C
Off-white or Black
-
2C
Off-white, Black
-
3C / 2C + E
Off-white, Black, Red
Off-white, Black, G/Y
4C / 3C + E
Off-white, Black, Red, Blue
Off-white, Black, Red, G/Y
5C / 4C + E
Black No. on white insulation
Off-white, Black, Red, Blue, G/Y
6C and over
Black No. on white insulation
Black No. on white insulation, G/Y
Technical Information
Inner covering
Note. 1. Flexible cable (Class5 Conductor) can be supplied
2. Earth core(G/Y) : Yellow/Green(Green base color with yellow stripe)
Offshore Cable
15
Halogen free & Mud resistant Offshore cable
LV Power & Lighting Cable 0.6/1kV RFOU, 0.6/1kV RFBU No. of Cores
No.
1
2
2C+E 2C+E 2C+E 2C+E 2C+E 2C+E 2C Earth 2C Earth 2C Earth 2C Earth 2C Earth 2C Earth 2C Earth 2C Earth 2C Earth
16
Conductor Nominal Area
Min. No. of wires
Max. overall dia.
mm2
EA
mm
1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 1.5 2.5 4 6 10 16 25 16 35 25 50 25 70 35 95 50 120 70 150 95 185 95 240 120
Offshore Cable
7 7 7 7 7 7 7 7 19 19 19 37 37 37 61 61 7 7 7 7 7 7 7 7 19 19 19 37 37 37 61 61 7 7 7 7 7 7 7 7 7 7 19 7 19 7 19 19 37 19 37 19 37 19 61 37
1.7 2.2 2.7 3.3 4.2 5.3 6.6 7.9 9.1 11.0 12.9 14.5 16.2 18.0 20.6 23.1 1.7 2.2 2.7 3.3 4.2 5.3 6.6 7.9 9.1 11.0 12.9 14.5 16.2 18.0 20.6 23.1 1.7 2.2 2.7 3.3 4.2 5.3 6.6 5.3 7.9 6.6 9.1 6.6 11.0 7.9 12.9 9.1 14.5 11.0 16.2 12.9 18.0 12.9 20.6 14.5
Thickness Thickness of of Insulation inner covering mm
1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6 1.8 2.0 2.2 2.4 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6 1.8 2.0 2.2 2.4 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.0 1.2 1.2 1.4 1.2 1.4 1.2 1.6 1.4 1.6 1.4 1.8 1.6 2.0 1.6 2.2 1.6
mm
Nominal dia. inner covering mm
Dia. of Thickness Overall diameter wire for of Nominal Tolerarmour sheath ance mm
Conductor Insulation Resistance Resistance (at 20℃) (at 20℃) (Max.) (Min.)
Test Voltage
Cable Weight
mm
mm
±mm
Ω/km
㏁-km
V/5min.
kg/km
1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.2 1.4 1.4 1.6 1.6 1.0 1.0 1.0 1.0 1.0 1.0 1.0
5.6 6.0 6.5 7.1 8.0 9.0 10.7 11.8 13.6 15.3 17.6 19.1 21.0 23.5 26.5 30.1 9.2 10.0 11.0 12.2 14.0 16.0 19.4 21.6 25.2 29.4 34.0 37.0 41.2 46.2 52.8 58.4 9.8 10.6 11.7 13.0 14.9 17.1 20.1
0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.4 0.4 0.4 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3
1.1 1.1 1.1 1.1 1.2 1.2 1.3 1.3 1.4 1.5 1.6 1.6 1.7 1.8 1.9 2.1 1.2 1.3 1.3 1.3 1.4 1.5 1.6 1.7 1.9 2.0 2.2 2.3 2.5 2.7 3.0 3.2 1.2 1.3 1.3 1.4 1.4 1.5 1.7
9.3 9.7 10.2 10.8 11.9 12.9 14.8 15.9 17.9 19.8 22.3 23.8 25.9 28.6 31.8 36.2 13.1 14.1 15.1 16.3 18.3 20.5 24.1 26.5 30.5 34.9 40.3 43.5 48.1 53.5 60.7 66.7 13.7 14.7 15.8 17.3 19.2 21.6 25.0
0.6 0.6 0.6 0.6 0.7 0.7 0.7 0.8 0.8 0.9 1.0 1.0 1.1 1.2 1.3 1.4 0.7 0.7 0.8 0.8 0.8 0.9 1.0 1.1 1.2 1.3 1.5 1.6 1.7 1.9 2.1 2.3 0.7 0.7 0.8 0.8 0.9 0.9 1.1
22.7
0.3
1.8
27.8
1.1
1.0
25.9
0.3
1.9
31.2
1.2
1.2
30.2
0.4
2.1
36.3
1.4
1.2
34.9
0.4
2.3
41.4
1.5
1.4
38.6
0.4
2.4
45.3
1.7
1.4
42.9
0.4
2.6
50.0
1.8
1.4
47.3
0.4
2.8
54.8
1.9
1.6
53.8
0.4
3.0
61.7
2.2
1,320 1,110 940 800 650 540 520 450 440 380 370 330 330 330 320 310 1,320 1,110 940 800 650 540 520 450 440 380 370 330 330 330 320 310 1,320 1,110 940 800 650 540 520 540 450 520 440 520 380 450 370 440 330 380 330 370 330 370 320 330
3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500
150 170 200 230 290 370 520 630 810 1,060 1,380 1,650 1,970 2,430 3,090 3,940 290 340 400 480 610 790 1,120 1,390 1,820 2,450 3,320 3,950 4,800 5,910 7,630 9,260 320 380 460 570 730 980 1,300
1.0
12.2 7.56 4.70 3.110 1.840 1.160 0.734 0.529 0.391 0.270 0.195 0.154 0.126 0.100 0.0762 0.0607 12.2 7.56 4.70 3.110 1.840 1.160 0.734 0.529 0.391 0.270 0.195 0.154 0.126 0.100 0.0762 0.0607 12.2 7.56 4.70 3.110 1.840 1.160 0.734 1.160 0.529 0.734 0.391 0.734 0.270 0.529 0.195 0.391 0.154 0.270 0.126 0.195 0.100 0.195 0.0762 0.154
1,690 2,090 2,920 3,830 4,730 5,790 6,870 8,760
LV Power & Lighting Cable
•
●
• • • •
NEK-606 (2009), IEC 60092-350, 353, 354, 376
4
4C+E 4C+E 4C+E 4C+E 4C+E 4C+E 4C Earth 4C Earth 4C Earth 4C Earth 4C Earth 4C Earth 4C Earth 4C Earth 4C Earth
EA
mm 1.7 2.2 2.7 3.3 4.2 5.3 6.6 7.9 9.1 11.0 12.9 14.5 16.2 18.0 20.6 23.1 1.7 2.2 2.7 3.3 4.2 5.3 6.6 5.3 7.9 6.6 9.1 6.6 11.0 7.9 12.9 9.1 14.5 11.0 16.2 12.9 18.0 12.9 20.6 14.5 1.7 2.2 2.7 3.3 4.2 5.3 6.6 7.9 9.1 11.0 12.9 14.5 16.2 18.0 20.6 23.1 1.7 2.2 2.7 3.3 4.2 5.3 6.6 5.3 7.9 6.6 9.1 6.6 11.0 7.9 12.9 9.1 14.5 11.0 16.2 12.9 18.0 12.9 20.6 14.5
7 7 7 7 7 7 7 7 19 19 19 37 37 37 61 61 7 7 7 7 7 7 7 7 7 7 19 7 19 7 19 19 37 19 37 19 37 19 61 37 7 7 7 7 7 7 7 7 19 19 19 37 37 37 61 61 7 7 7 7 7 7 7 7 7 7 19 7 19 7 19 19 37 19 37 19 37 19 61 37
mm 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6 1.8 2.0 2.2 2.4 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.0 1.2 1.2 1.4 1.2 1.4 1.2 1.6 1.4 1.6 1.4 1.8 1.6 2.0 1.6 2.2 1.6 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6 1.8 2.0 2.2 2.4 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.0 1.2 1.2 1.4 1.2 1.4 1.2 1.6 1.4 1.6 1.4 1.8 1.6 2.0 1.6 2.2 1.6
mm 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6 1.6 1.0 1.0 1.0 1.0 1.0 1.0 1.0
mm 9.8 10.6 11.7 13.0 14.9 17.1 20.7 23.1 27.0 31.5 36.4 40.1 44.1 50.1 56.6 62.6 10.7 11.7 12.9 14.3 16.5 18.9 22.4
Dia. of wire for armour mm 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3
Thickness Overall diameter of Nominal Tolersheath ance mm 1.2 1.3 1.3 1.4 1.4 1.5 1.7 1.8 1.9 2.1 2.3 2.5 2.6 2.9 3.1 3.4 1.3 1.3 1.4 1.4 1.5 1.6 1.7
mm 13.7 14.7 15.8 17.3 19.2 21.6 25.6 28.2 32.3 37.6 42.9 47.0 51.2 57.8 64.7 71.3 14.8 15.8 17.2 18.6 21.0 23.6 27.3
±mm 0.7 0.7 0.8 0.8 0.9 0.9 1.1 1.1 1.3 1.4 1.6 1.7 1.8 2.0 2.2 2.4 0.7 0.8 0.8 0.9 0.9 1.0 1.1
1.0
25.3
0.3
1.9
30.6
1.2
1.2
29.8
0.3
2.0
35.3
1.4
1.2
33.7
0.4
2.2
40.0
1.5
1.4
39.5
0.4
2.4
46.2
1.7
1.4
43.2
0.4
2.6
50.3
1.8
1.4
47.9
0.4
2.8
55.4
2.0
1.6
53.7
0.4
3.0
61.6
2.1
1.6
60.4
0.4
3.3
68.9
2.4
1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6 1.6 1.8 1.0 1.0 1.0 1.0 1.0 1.0 1.0
10.7 11.7 12.9 14.3 16.5 18.9 23.0 25.7 30.8 34.9 40.9 44.5 49.7 55.7 62.9 70.1 11.7 12.8 14.2 15.8 18.2 20.9 25.0
0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3
1.3 1.3 1.4 1.4 1.5 1.6 1.8 1.9 2.1 2.3 2.5 2.6 2.9 3.1 3.4 3.7 1.3 1.4 1.4 1.5 1.6 1.7 1.9
14.8 15.8 17.2 18.6 21.0 23.6 28.1 31.0 36.9 41.4 47.8 51.6 57.4 63.8 71.6 79.4 15.8 17.1 18.5 20.3 22.9 25.8 30.3
0.7 0.8 0.8 0.9 0.9 1.0 1.1 1.2 1.4 1.5 1.7 1.8 2.0 2.2 2.4 2.7 0.8 0.8 0.9 0.9 1.0 1.1 1.2
1.2
28.9
0.3
2.0
34.4
1.3
1.2
33.2
0.4
2.2
39.5
1.5
1.2
37.6
0.4
2.4
44.3
1.6
1.4
44.0
0.4
2.6
51.1
1.8
1.4
48.1
0.4
2.8
55.6
2.0
1.6
54.0
0.4
3.0
61.9
2.2
1.6
59.9
0.4
3.3
68.4
2.4
1.8
67.9
0.4
3.6
77.0
2.6
Conductor Insulation Resistance Resistance (at 20℃) (at 20℃) (Max.) (Min.) Ω/km 12.2 7.56 4.70 3.110 1.840 1.160 0.734 0.529 0.391 0.270 0.195 0.154 0.126 0.100 0.0762 0.0607 12.2 7.56 4.70 3.110 1.840 1.160 0.734 1.160 0.529 0.734 0.391 0.734 0.270 0.529 0.195 0.391 0.154 0.270 0.126 0.195 0.100 0.195 0.0762 0.154 12.2 7.56 4.70 3.110 1.840 1.160 0.734 0.529 0.391 0.270 0.195 0.154 0.126 0.100 0.0762 0.0607 12.2 7.56 4.70 3.110 1.840 1.160 0.734 1.160 0.529 0.734 0.391 0.734 0.270 0.529 0.195 0.391 0.154 0.270 0.126 0.195 0.100 0.195 0.0762 0.154
㏁-km 1,320 1,110 940 800 650 540 520 450 440 380 370 330 330 330 320 310 1,320 1,110 940 800 650 540 520 540 450 520 440 520 380 450 370 440 330 380 330 370 330 370 320 330 1,320 1,110 940 800 650 540 520 450 440 380 370 330 330 330 320 310 1,320 1,110 940 800 650 540 520 540 450 520 440 520 380 450 370 440 330 380 330 370 330 370 320 330
Test Voltage
Cable Weight
V/5min. 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500
kg/km 320 380 460 570 730 980 1,420 1,790 2,340 3,290 4,340 5,290 6,320 7,960 10,120 12,380 380 450 550 680 900 1,210 1,640
LV Power & Lighting Cable
mm2 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 1.5 2.5 4 6 10 16 25 16 35 25 50 25 70 35 95 50 120 70 150 95 185 95 240 120 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 1.5 2.5 4 6 10 16 25 16 35 25 50 25 70 35 95 50 120 70 150 95 185 95 240 120
Thickness Thickness Nominal of of dia. Insulation inner inner covering covering
2,150
Instrumentation & Communication Cable
3C+E 3C+E 3C+E 3C+E 3C+E 3C+E 3C Earth 3C Earth 3C Earth 3C Earth 3C Earth 3C Earth 3C Earth 3C Earth 3C Earth
Max. overall dia.
2,790 3,770 5,040 6,160 7,520 9,150 11,610
Earthing & Bonding wire
3
Min. No. of wires
380 450 550 680 900 1,210 1,770 2,250 3,150 4,160 5,580 6,700 8,200 10,140 12,960 16,000 430 520 640 810 1,070 1,450 2,030
VFD Cable
No.
Conductor Nominal Area
2,720 3,550 4,680
Technical Information
No. of Cores
HV Power Cable
0.6/1kV RFOU, 0.6/1kV RFCU, 0.6/1kV RFBU
6,270 7,660 9,460 11,460 14,670
Offshore Cable
17
Halogen free & Mud resistant Offshore cable
LV Power & Lighting Cable 0.6/1kV RFOU, 0.6/1kV RFCU, 0.6/1kV RFBU No. of Cores
No.
5 7 9 12 14 16 19 24 27 30 37 44 5 7 9 12 14 16 19 24 27 30 37 44 5 7 9 12 14 16 19 24 27 30 37 44 5 7 9 12 14 16 19 24 27 30 37 44
18
Conductor Nominal Area
Min. No. of wires
Max. overall dia.
mm2
EA
mm
1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 4 4 4 4 4 4 4 4 4 4 4 4
Offshore Cable
7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7
1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7
Thickness Thickness of of Insulation inner covering mm
1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0
mm
1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.2 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.2 1.2 1.4
Nominal dia. inner covering mm
10.9 11.9 13.9 15.7 16.6 17.5 18.5 21.8 22.3 23.2 25.1 29.2 11.7 12.8 15.0 17.0 17.9 18.9 20.0 23.6 24.2 25.1 28.0 31.6 12.8 14.0 16.5 18.6 19.7 20.8 22.0 26.0 26.6 28.5 30.8 34.8 14.2 15.5 18.3 20.7 21.9 23.2 24.5 29.8 30.5 31.7 34.3 39.2
Dia. of Thickness Overall diameter wire for of Nominal Tolerarmour sheath ance mm
0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.4 0.4
mm
mm
1.3 1.3 1.4 1.5 1.5 1.6 1.6 1.7 1.7 1.8 1.9 2.0 1.3 1.4 1.5 1.5 1.6 1.6 1.7 1.8 1.8 1.9 2.0 2.1 1.4 1.4 1.5 1.6 1.6 1.7 1.7 1.9 1.9 2.0 2.1 2.3 1.4 1.5 1.6 1.7 1.7 1.8 1.8 2.0 2.1 2.1 2.2 2.4
15.0 16.0 18.2 20.2 21.1 22.2 23.2 26.7 27.2 28.3 30.4 34.7 15.8 17.1 19.5 21.5 22.6 23.6 24.9 28.7 29.3 30.4 33.5 37.7 17.1 18.3 21.0 23.3 24.4 25.7 26.9 31.3 31.9 34.0 36.9 41.3 18.5 20.0 23.0 25.6 26.8 28.3 29.6 35.3 36.6 37.8 40.6 45.9
Conductor Insulation Resistance Resistance (at 20℃) (at 20℃) (Max.) (Min.)
Test Voltage
Cable Weight
±mm
Ω/km
㏁-km
V/5min.
kg/km
0.8 0.8 0.8 0.9 0.9 1.0 1.0 1.1 1.1 1.1 1.2 1.3 0.8 0.8 0.9 0.9 1.0 1.0 1.0 1.2 1.2 1.2 1.3 1.4 0.8 0.8 0.9 1.0 1.0 1.1 1.1 1.2 1.3 1.3 1.4 1.5 0.9 0.9 1.0 1.1 1.1 1.1 1.2 1.4 1.4 1.4 1.5 1.7
18.2 18.2 18.2 18.2 18.2 18.2 18.2 18.2 18.2 18.2 18.2 18.2 12.2 12.2 12.2 12.2 12.2 12.2 12.2 12.2 12.2 12.2 12.2 12.2 7.56 7.56 7.56 7.56 7.56 7.56 7.56 7.56 7.56 7.56 7.56 7.56 4.70 4.70 4.70 4.70 4.70 4.70 4.70 4.70 4.70 4.70 4.70 4.70
1,490 1,490 1,490 1,490 1,490 1,490 1,490 1,490 1,490 1,490 1,490 1,490 1,320 1,320 1,320 1,320 1,320 1,320 1,320 1,320 1,320 1,320 1,320 1,320 1,110 1,110 1,110 1,110 1,110 1,110 1,110 1,110 1,110 1,110 1,110 1,110 940 940 940 940 940 940 940 940 940 940 940 940
3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500
360 430 520 630 690 770 850 1,040 1,120 1,220 1,420 1,750 410 500 610 730 820 900 1,010 1,250 1,340 1,460 1,800 2,190 500 600 740 910 1,010 1,120 1,260 1,570 1,700 1,940 2,370 2,790 610 750 930 1,160 1,290 1,440 1,630 2,130 2,410 2,600 3,070 3,680
LV Power & Lighting Cable
•
●
• • • •
HV Power Cable
NEK-606 (2009), IEC 60092-350, 353, 354, 376
Cable Designation (P17) LV Power & Lighting Cable
0.6/1kV BU
Application Standard - Design guide
: NEK-606 & IEC 60092-353
- Flame retardant
: IEC 60332-1 &
IEC 60332-3 Category A
- Fire resistance
: IEC 60331-21(90min) IEC 60331-1,-2(120min)
- Halogen content
: IEC 60754-1, 0.5%↓
- Cold bend / impact
: CSA 22.2 No.03 (-40℃/-35℃)
- Mud resistant
: NEK-606 (Mud type only)
- Smoke light transmittance
: IEC 61034, 60%↑
- Sunlight (UV) resistant
: UL 1581
Instrumentation & Communication Cable
0.6/1KV BU
Sectional view
Classification
Code
Insulation
Construction detail - Stranded tinned annealed copper wires as per IEC 60228, Class 2
Conductor Fire resisting layer
Earthing & Bonding wire
Construction
B
- Mica/glass tape - HF EPR as per IEC 60092-351 - Insulated cores shall be cabled
Cabling
- Flame retardant & non-hygroscopic fillers may be used - Suitable tape(s) may be applied on the cabled core - A Filler may be applied to obtain a circular Cable - SHF2 or SHF Mud as per IEC 60092-359 - Outer sheath color : Black No. of cores
Core identification
Without Earth core
VFD Cable
U
With Earth core
1C
Off-white or Black
-
2C
Off-white, Black
-
3C / 2C + E
Off-white, Black, Red
Off-white, Black, G/Y
4C / 3C + E
Off-white, Black, Red, Blue
Off-white, Black, Red, G/Y
5C / 4C + E
Black No. on white insulation
Off-white, Black, Red, Blue, G/Y
6C and over
Black No. on white insulation
Black No. on white insulation, G/Y
Technical Information
Sheath
Note. 1. Flexible cable (Class5 Conductor) can be supplied
2. Earth core(G/Y) : Yellow/Green(Green base color with yellow stripe)
Offshore Cable
19
Halogen free & Mud resistant Offshore cable
LV Power & Lighting Cable 0.6/1kV BU No. of Cores
No.
1
2
2C+E 2C+E 2C+E 2C+E 2C+E 2C+E 2C Earth 2C Earth 2C Earth 2C Earth 2C Earth 2C Earth 2C Earth 2C Earth 2C Earth
20
Conductor Nominal Area
Min. No. of wires
Max. overall dia.
mm2
EA
mm
1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 1.5 2.5 4 6 10 16 25 16 35 25 50 25 70 35 95 50 120 70 150 95 185 95 240 120
Offshore Cable
7 7 7 7 7 7 7 7 19 19 19 37 37 37 61 61 7 7 7 7 7 7 7 7 19 19 19 37 37 37 61 61 7 7 7 7 7 7 7 7 7 7 19 7 19 7 19 19 37 19 37 19 37 19 61 37
1.7 2.2 2.7 3.3 4.2 5.3 6.6 7.9 9.1 11.0 12.9 14.5 16.2 18.0 20.6 23.1 1.7 2.2 2.7 3.3 4.2 5.3 6.6 7.9 9.1 11.0 12.9 14.5 16.2 18.0 20.6 23.1 1.7 2.2 2.7 3.3 4.2 5.3 6.6 5.3 7.9 6.6 9.1 6.6 11.0 7.9 12.9 9.1 14.5 11.0 16.2 12.9 18.0 12.9 20.6 14.5
Thickness of Insulation
Thickness of sheath
mm
mm
1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6 1.8 2.0 2.2 2.4 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6 1.8 2.0 2.2 2.4 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.0 1.2 1.2 1.4 1.2 1.4 1.2 1.6 1.4 1.6 1.4 1.8 1.6 2.0 1.6 2.2 1.6
Overall diameter Nominal
Tolerance
mm
±mm
1.0 1.0 1.0 1.0 1.1 1.1 1.2 1.2 1.3 1.4 1.4 1.5 1.6 1.7 1.8 1.9 1.1 1.2 1.2 1.2 1.3 1.4 1.5 1.6 1.8 1.9 2.1 2.2 2.4 2.5 2.8 3.0 1.2 1.2 1.2 1.3 1.4 1.4 1.6
6.3 6.7 7.2 7.8 8.9 9.9 11.8 12.9 14.9 16.8 19.1 20.9 22.9 25.4 28.6 31.8 10.6 11.6 12.6 13.8 15.8 18.0 21.6 24.0 28.0 31.8 36.8 40.2 44.2 49.0 55.6 61.6 11.4 12.3 13.4 14.9 17.0 19.2 22.6
0.5 0.5 0.5 0.5 0.6 0.6 0.7 0.7 0.7 0.8 0.9 0.9 1.0 1.1 1.2 1.3 0.6 0.6 0.7 0.7 0.8 0.8 0.9 1.0 1.1 1.3 1.4 1.5 1.6 1.8 2.0 2.1 0.6 0.7 0.7 0.7 0.8 0.9 1.0
1.7
25.4
1.1
1.8
29.0
1.2
1.9
32.6
1.3
2.1
37.8
1.4
2.3
41.7
1.6
2.4
46.0
1.7
2.6
50.4
1.8
2.8
56.8
2.0
Conductor Resistance (at 20℃) (Max.)
Insulation Resistance (at 20℃) (Min.)
Test Voltage
Cable Weight
Ω/km
㏁-km
V/5min.
kg/km
12.2 7.56 4.70 3.110 1.840 1.160 0.734 0.529 0.391 0.270 0.195 0.154 0.126 0.100 0.0762 0.0607 12.2 7.56 4.70 3.110 1.840 1.160 0.734 0.529 0.391 0.270 0.195 0.154 0.126 0.100 0.0762 0.0607 12.2 7.56 4.70 3.110 1.840 1.160 0.734 1.160 0.529 0.734 0.391 0.734 0.270 0.529 0.195 0.391 0.154 0.270 0.126 0.195 0.100 0.195 0.0762 0.154
1,320 1,110 940 800 650 540 520 450 440 380 370 330 330 330 320 310 1,320 1,110 940 800 650 540 520 450 440 380 370 330 330 330 320 310 1,320 1,110 940 800 650 540 520 540 450 520 440 520 380 450 370 440 330 380 330 370 330 370 320 330
3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500
60 80 100 120 170 240 350 460 610 830 1,120 1,370 1,670 2,080 2,690 3,350 170 210 260 330 430 590 870 1,120 1,510 2,050 2,770 3,370 4,090 5,070 6,580 8,130 200 250 310 410 560 770 1,060 1,420 1,800 2,400 3,250 4,080 5,040 6,020 7,720
LV Power & Lighting Cable
•
●
• • • •
NEK-606 (2009), IEC 60092-350, 353, 354, 376
4
4C+E 4C+E 4C+E 4C+E 4C+E 4C+E 4C Earth 4C Earth 4C Earth 4C Earth 4C Earth 4C Earth 4C Earth 4C Earth 4C Earth
mm 1.7 2.2 2.7 3.3 4.2 5.3 6.6 7.9 9.1 11.0 12.9 14.5 16.2 18.0 20.6 23.1 1.7 2.2 2.7 3.3 4.2 5.3 6.6 5.3 7.9 6.6 9.1 6.6 11.0 7.9 12.9 9.1 14.5 11.0 16.2 12.9 18.0 12.9 20.6 14.5 1.7 2.2 2.7 3.3 4.2 5.3 6.6 7.9 9.1 11.0 12.9 14.5 16.2 18.0 20.6 23.1 1.7 2.2 2.7 3.3 4.2 5.3 6.6 5.3 7.9 6.6 9.1 6.6 11.0 7.9 12.9 9.1 14.5 11.0 16.2 12.9 18.0 12.9 20.6 14.5
Thickness of sheath
mm 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6 1.8 2.0 2.2 2.4 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.0 1.2 1.2 1.4 1.2 1.4 1.2 1.6 1.4 1.6 1.4 1.8 1.6 2.0 1.6 2.2 1.6 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6 1.8 2.0 2.2 2.4 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.0 1.2 1.2 1.4 1.2 1.4 1.2 1.6 1.4 1.6 1.4 1.8 1.6 2.0 1.6 2.2 1.6
mm 1.2 1.2 1.2 1.3 1.4 1.4 1.6 1.7 1.8 2.0 2.2 2.3 2.5 2.7 2.9 3.2 1.2 1.2 1.3 1.3 1.4 1.5 1.7
mm 11.4 12.3 13.4 14.9 17.0 19.2 23.2 25.8 30.1 34.1 39.5 43.1 47.4 52.8 59.6 66.3 12.5 13.5 14.9 16.3 18.7 21.3 25.3
±mm 0.6 0.7 0.7 0.7 0.8 0.9 1.0 1.1 1.2 1.3 1.5 1.6 1.7 1.9 2.1 2.3 0.7 0.7 0.7 0.8 0.9 0.9 1.1
1.8
28.3
1.1
1.9
32.4
1.3
2.1
36.7
1.4
2.3
42.5
1.6
2.5
46.8
1.7
2.6
51.5
1.8
2.8
56.7
2.0
3.1
64.0
2.2
1.2 1.2 1.3 1.3 1.4 1.5 1.7 1.8 2.0 2.1 2.4 2.5 2.7 2.9 3.2 3.5 1.2 1.3 1.3 1.4 1.5 1.6 1.8
12.5 13.5 14.9 16.3 18.7 21.3 25.8 28.7 33.6 37.9 44.1 48.1 52.9 58.8 66.7 74.0 13.7 15.0 16.3 18.1 20.8 23.7 28.1
0.7 0.7 0.7 0.8 0.9 0.9 1.1 1.2 1.3 1.4 1.6 1.7 1.9 2.1 2.3 2.5 0.7 0.8 0.8 0.8 0.9 1.0 1.1
1.9
31.7
1.3
2.1
36.3
1.4
2.2
40.9
1.5
2.5
47.6
1.7
2.7
52.3
1.9
2.9
57.8
2.0
3.1
63.6
2.2
3.4
71.8
2.5
Overall diameter Nominal
Tolerance
Conductor Resistance (at 20℃) (Max.) Ω/km 12.2 7.56 4.70 3.110 1.840 1.160 0.734 0.529 0.391 0.270 0.195 0.154 0.126 0.100 0.0762 0.0607 12.2 7.56 4.70 3.110 1.840 1.160 0.734 1.160 0.529 0.734 0.391 0.734 0.270 0.529 0.195 0.391 0.154 0.270 0.126 0.195 0.100 0.195 0.0762 0.154 12.2 7.56 4.70 3.110 1.840 1.160 0.734 0.529 0.391 0.270 0.195 0.154 0.126 0.100 0.0762 0.0607 12.2 7.56 4.70 3.110 1.840 1.160 0.734 1.160 0.529 0.734 0.391 0.734 0.270 0.529 0.195 0.391 0.154 0.270 0.126 0.195 0.100 0.195 0.0762 0.154
Insulation Resistance (at 20℃) (Min.) ㏁-km 1,320 1,110 940 800 650 540 520 450 440 380 370 330 330 330 320 310 1,320 1,110 940 800 650 540 520 540 450 520 440 520 380 450 370 440 330 380 330 370 330 370 320 330 1,320 1,110 940 800 650 540 520 450 440 380 370 330 330 330 320 310 1,320 1,110 940 800 650 540 520 540 450 520 440 520 380 450 370 440 330 380 330 370 330 370 320 330
Test Voltage
Cable Weight
V/5min. 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500
kg/km 200 250 310 410 560 770 1,160 1,510 2,040 2,770 3,760 4,600 5,580 6,970 9,010 11,190 240 300 390 500 710 990 1,400
LV Power & Lighting Cable
7 7 7 7 7 7 7 7 19 19 19 37 37 37 61 61 7 7 7 7 7 7 7 7 7 7 19 7 19 7 19 19 37 19 37 19 37 19 61 37 7 7 7 7 7 7 7 7 19 19 19 37 37 37 61 61 7 7 7 7 7 7 7 7 7 7 19 7 19 7 19 19 37 19 37 19 37 19 61 37
Thickness of Insulation
1,850
Instrumentation & Communication Cable
3C+E 3C+E 3C+E 3C+E 3C+E 3C+E 3C Earth 3C Earth 3C Earth 3C Earth 3C Earth 3C Earth 3C Earth 3C Earth 3C Earth
EA
Max. overall dia.
2,390 3,230 4,370 5,460 6,710 8,110 10,460
Earthing & Bonding wire
3
mm2 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 1.5 2.5 4 6 10 16 25 16 35 25 50 25 70 35 95 50 120 70 150 95 185 95 240 120 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 1.5 2.5 4 6 10 16 25 16 35 25 50 25 70 35 95 50 120 70 150 95 185 95 240 120
Min. No. of wires
240 300 390 500 710 990 1,500 1,950 2,650 3,580 4,890 5,980 7,260 9,060 11,770 14,600 290 370 470 620 870 1,230 1,750
VFD Cable
No.
Conductor Nominal Area
2,340 3,030 4,070
Technical Information
No. of Cores
HV Power Cable
0.6/1kV BU
5,560 6,910 8,500 10,330 13,340
Offshore Cable
21
Halogen free & Mud resistant Offshore cable
LV Power & Lighting Cable 0.6/1kV BU No. of Cores
No.
5 7 9 12 14 16 19 24 27 30 37 44 5 7 9 12 14 16 19 24 27 30 37 44 5 7 9 12 14 16 19 24 27 30 37 44 5 7 9 12 14 16 19 24 27 30 37 44
22
Conductor Nominal Area
Min. No. of wires
mm2
EA
1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 4 4 4 4 4 4 4 4 4 4 4 4
Offshore Cable
Max. overall dia. mm
7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7
1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7
Thickness of Insulation
Thickness of sheath
mm
mm
1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0
1.2 1.3 1.3 1.4 1.5 1.5 1.6 1.7 1.7 1.8 1.9 2.0 1.2 1.3 1.4 1.5 1.5 1.6 1.6 1.8 1.8 1.9 1.9 2.1 1.3 1.3 1.5 1.5 1.6 1.6 1.7 1.9 1.9 2.0 2.1 2.2 1.3 1.4 1.5 1.6 1.7 1.7 1.8 2.0 2.0 2.1 2.2 2.4
Overall diameter Nominal
Tolerance
mm
±mm
12.9 14.2 16.5 18.8 20.0 21.1 22.4 26.4 27.0 28.2 30.8 34.8 13.7 15.1 17.8 20.2 21.3 22.7 23.9 28.4 29.2 30.5 32.9 37.4 15.0 16.3 19.5 21.9 23.3 24.6 26.1 31.2 31.9 33.3 36.1 40.8 16.3 18.0 21.3 24.2 25.7 27.1 29.0 34.4 35.2 36.7 39.8 45.2
0.7 0.7 0.8 0.9 0.9 0.9 1.0 1.1 1.1 1.1 1.2 1.3 0.7 0.8 0.8 0.9 0.9 1.0 1.0 1.2 1.2 1.2 1.3 1.4 0.8 0.8 0.9 1.0 1.0 1.0 1.1 1.2 1.3 1.3 1.4 1.5 0.8 0.8 0.9 1.0 1.1 1.1 1.2 1.3 1.4 1.4 1.5 1.7
Conductor Resistance (at 20℃) (Max.)
Insulation Resistance (at 20℃) (Min.)
Test Voltage
Cable Weight
Ω/km
㏁-km
V/5min.
kg/km
18.2 18.2 18.2 18.2 18.2 18.2 18.2 18.2 18.2 18.2 18.2 18.2 12.2 12.2 12.2 12.2 12.2 12.2 12.2 12.2 12.2 12.2 12.2 12.2 7.56 7.56 7.56 7.56 7.56 7.56 7.56 7.56 7.56 7.56 7.56 7.56 4.70 4.70 4.70 4.70 4.70 4.70 4.70 4.70 4.70 4.70 4.70 4.70
1,490 1,490 1,490 1,490 1,490 1,490 1,490 1,490 1,490 1,490 1,490 1,490 1,320 1,320 1,320 1,320 1,320 1,320 1,320 1,320 1,320 1,320 1,320 1,320 1,110 1,110 1,110 1,110 1,110 1,110 1,110 1,110 1,110 1,110 1,110 1,110 940 940 940 940 940 940 940 940 940 940 940 940
3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500
230 300 370 480 550 610 710 900 980 1,090 1,330 1,580 270 350 450 580 650 740 850 1,090 1,210 1,340 1,600 1,920 340 440 580 730 840 940 1,100 1,430 1,570 1,730 2,090 2,480 440 580 740 960 1,110 1,250 1,480 1,880 2,070 2,290 2,770 3,320
LV Power & Lighting Cable
•
●
• • • •
HV Power Cable
NEK-606 (2009), IEC 60092-350, 353, 354, 376
Cable Designation (P5, P5/P12) LV Power & Lighting Cable
0.6/1kV BFOU, BFCU, BFBU
Application Standard - Design guide
: NEK-606 & IEC 60092-353
- Flame retardant
: IEC 60332-1 &
IEC 60332-3 Category A
- Fire resistance
: IEC 60331-21(90min) IEC 60331-1,-2(120min)
- Halogen content
: IEC 60754-1, 0.5%↓
- Cold bend / impact
: CSA 22.2 No.03 (-40℃/-35℃)
- Mud resistant
: NEK-606 (Mud type only)
- Smoke light transmittance
: IEC 61034, 60%↑
- Sunlight (UV) resistant
: UL 1581
Instrumentation & Communication Cable
0.6/1kV BFOU
Sectional view
Classification
Code
Insulation
Construction detail - Stranded tinned annealed copper wires as per IEC 60228, Class 2
Conductor Fire resisting layer
Earthing & Bonding wire
Construction
B
- Mica/glass tape - HF EPR as per IEC 60092-351 - Insulated cores shall be cabled
Cabling
- Flame retardant & non-hygroscopic fillers may be used - Suitable tape(s) may be applied on the cabled core
Sheath
- Flame retardant halogen free thermoset compound
O
- Braid of tinned copper wire (O) / bronze wire (B) /galvanized steel wire (C)
(B,C) U
- A suitable separator tape(s) may be applied under/over the armor - SHF2 or SHF Mud as per IEC 60092-359 - Outer sheath color : Black No. of cores
Core identification
Without Earth core
With Earth core
1C
Off-white or Black
-
2C
Off-white, Black
-
3C / 2C + E
Off-white, Black, Red
Off-white, Black, G/Y
4C / 3C + E
Off-white, Black, Red, Blue
Off-white, Black, Red, G/Y
5C / 4C + E
Black No. on white insulation
Off-white, Black, Red, Blue, G/Y
6C and over
Black No. on white insulation
Black No. on white insulation, G/Y
Technical Information
Armor
F
VFD Cable
- A Filler may be applied to obtain a circular Cable Inner covering
Note. 1. Flexible cable (Class5 Conductor) can be supplied
2. Earth core(G/Y) : Yellow/Green(Green base color with yellow stripe)
Offshore Cable
23
Halogen free & Mud resistant Offshore cable
LV Power & Lighting Cable 0.6/1kV BFOU, 0.6/1kV BFBU No. of Cores
No.
1
2
2C+E 2C+E 2C+E 2C+E 2C+E 2C+E 2C Earth 2C Earth 2C Earth 2C Earth 2C Earth 2C Earth 2C Earth 2C Earth 2C Earth
24
Conductor Nominal Area
Min. No. of wires
Max. overall dia.
mm2
EA
mm
1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 1.5 2.5 4 6 10 16 25 16 35 25 50 25 70 35 95 50 120 70 150 95 185 95 240 120
Offshore Cable
7 7 7 7 7 7 7 7 19 19 19 37 37 37 61 61 7 7 7 7 7 7 7 7 19 19 19 37 37 37 61 61 7 7 7 7 7 7 7 7 7 7 19 7 19 7 19 19 37 19 37 19 37 19 61 37
1.7 2.2 2.7 3.3 4.2 5.3 6.6 7.9 9.1 11.0 12.9 14.5 16.2 18.0 20.6 23.1 1.7 2.2 2.7 3.3 4.2 5.3 6.6 7.9 9.1 11.0 12.9 14.5 16.2 18.0 20.6 23.1 1.7 2.2 2.7 3.3 4.2 5.3 6.6 5.3 7.9 6.6 9.1 6.6 11.0 7.9 12.9 9.1 14.5 11.0 16.2 12.9 18.0 12.9 20.6 14.5
Thickness Thickness Nominal of of dia. Insulation inner inner covering covering mm
1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6 1.8 2.0 2.2 2.4 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6 1.8 2.0 2.2 2.4 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.0 1.2 1.2 1.4 1.2 1.4 1.2 1.6 1.4 1.6 1.4 1.8 1.6 2.0 1.6 2.2 1.6
mm
mm
Dia. of wire for armour mm
Thickness Overall diameter of Nominal Tolersheath ance mm
mm
±mm
1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.4 1.4 1.4 1.6 1.6 1.0 1.0 1.0 1.0 1.0 1.0 1.0
6.1 6.5 7.0 7.6 8.5 9.5 11.2 12.3 14.1 15.8 18.1 19.7 21.5 23.8 26.8 30.4 10.2 11.0 12.0 13.2 15.0 17.0 20.4 22.6 26.2 30.4 35.0 38.6 42.2 46.8 53.4 59.0 10.8 11.7 12.8 14.1 16.0 18.2 21.2
0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3
1.1 1.1 1.1 1.2 1.2 1.2 1.3 1.3 1.4 1.5 1.6 1.6 1.7 1.8 1.9 2.1 1.3 1.3 1.3 1.4 1.5 1.5 1.7 1.8 1.9 2.1 2.3 2.4 2.6 2.7 3.0 3.2 1.3 1.3 1.4 1.4 1.5 1.6 1.7
9.8 10.2 10.7 11.5 12.4 13.4 15.3 16.4 18.4 20.3 22.8 24.4 26.4 28.9 32.1 36.5 14.3 15.1 16.1 17.5 19.5 21.5 25.3 27.7 31.5 36.5 41.5 45.3 49.3 54.1 61.3 67.3 14.9 15.8 17.1 18.4 20.5 22.9 26.1
0.6 0.6 0.6 0.6 0.7 0.7 0.8 0.8 0.9 0.9 1.0 1.0 1.1 1.2 1.3 1.4 0.7 0.8 0.8 0.8 0.9 0.9 1.1 1.1 1.2 1.4 1.5 1.7 1.8 1.9 2.1 2.3 0.7 0.8 0.8 0.9 0.9 1.0 1.1
1.0
23.8
0.3
1.8
28.9
1.2
1.0
27.0
0.3
1.9
32.3
1.3
1.2
31.2
0.4
2.1
37.3
1.4
1.2
36.0
0.4
2.3
42.5
1.6
1.4
39.9
0.4
2.5
46.8
1.7
1.4
44.0
0.4
2.6
51.1
1.8
1.4
48.0
0.4
2.8
55.5
2.0
1.6
54.6
0.4
3.1
62.7
2.2
Conductor Insulation Resistance Resistance (at 20℃) (at 20℃) (Max.) (Min.)
Test Voltage
Cable Weight
Ω/km
㏁-km
V/5min.
kg/km
12.2 7.56 4.70 3.110 1.840 1.160 0.734 0.529 0.391 0.270 0.195 0.154 0.126 0.100 0.0762 0.0607 12.2 7.56 4.70 3.110 1.840 1.160 0.734 0.529 0.391 0.270 0.195 0.154 0.126 0.100 0.0762 0.0607 12.2 7.56 4.70 3.110 1.840 1.160 0.734 1.160 0.529 0.734 0.391 0.734 0.270 0.529 0.195 0.391 0.154 0.270 0.126 0.195 0.100 0.195 0.0762 0.154
1,320 1,110 940 800 650 540 520 450 440 380 370 330 330 330 320 310 1,320 1,110 940 800 650 540 520 450 440 380 370 330 330 330 320 310 1,320 1,110 940 800 650 540 520 540 450 520 440 520 380 450 370 440 330 380 330 370 330 370 320 330
3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500
170 190 210 250 310 390 530 650 830 1,080 1,410 1,680 2,000 2,440 3,100 3,960 330 380 450 540 660 840 1,170 1,450 1,870 2,620 3,410 4,130 4,900 5,950 7,670 9,310 370 430 520 630 800 1,050 1,360 1,750 2,150 2,990 3,910 4,850 5,880 6,920 8,860
LV Power & Lighting Cable
•
●
• • • •
NEK-606 (2009), IEC 60092-350, 353, 354, 376
4
4C+E 4C+E 4C+E 4C+E 4C+E 4C+E 4C Earth 4C Earth 4C Earth 4C Earth 4C Earth 4C Earth 4C Earth 4C Earth 4C Earth
EA
mm 1.7 2.2 2.7 3.3 4.2 5.3 6.6 7.9 9.1 11.0 12.9 14.5 16.2 18.0 20.6 23.1 1.7 2.2 2.7 3.3 4.2 5.3 6.6 5.3 7.9 6.6 9.1 6.6 11.0 7.9 12.9 9.1 14.5 11.0 16.2 12.9 18.0 12.9 20.6 14.5 1.7 2.2 2.7 3.3 4.2 5.3 6.6 7.9 9.1 11.0 12.9 14.5 16.2 18.0 20.6 23.1 1.7 2.2 2.7 3.3 4.2 5.3 6.6 5.3 7.9 6.6 9.1 6.6 11.0 7.9 12.9 9.1 14.5 11.0 16.2 12.9 18.0 12.9 20.6 14.5
7 7 7 7 7 7 7 7 19 19 19 37 37 37 61 61 7 7 7 7 7 7 7 7 7 7 19 7 19 7 19 19 37 19 37 19 37 19 61 37 7 7 7 7 7 7 7 7 19 19 19 37 37 37 61 61 7 7 7 7 7 7 7 7 7 7 19 7 19 7 19 19 37 19 37 19 37 19 61 37
mm 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6 1.8 2.0 2.2 2.4 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.0 1.2 1.2 1.4 1.2 1.4 1.2 1.6 1.4 1.6 1.4 1.8 1.6 2.0 1.6 2.2 1.6 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6 1.8 2.0 2.2 2.4 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.0 1.2 1.2 1.4 1.2 1.4 1.2 1.6 1.4 1.6 1.4 1.8 1.6 2.0 1.6 2.2 1.6
Dia. of wire for armour
Thickness Overall diameter of Nominal Tolersheath ance
mm 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.2 1.4 1.4 1.6 1.6 1.6 1.0 1.0 1.0 1.0 1.0 1.0 1.0
mm 10.8 11.7 12.8 14.1 16.0 18.2 21.8 24.2 28.9 32.5 37.5 41.3 45.2 50.8 57.2 63.3 11.9 12.9 14.1 15.5 17.7 20.1 23.7
mm 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3
mm 1.3 1.3 1.4 1.4 1.5 1.6 1.7 1.8 2.0 2.2 2.4 2.5 2.7 2.9 3.2 3.4 1.3 1.4 1.4 1.5 1.6 1.7 1.8
mm 14.9 15.8 17.1 18.4 20.5 22.9 26.7 29.3 34.4 38.8 44.2 48.2 52.5 58.5 65.5 72.0 16.0 17.2 18.4 20.0 22.4 25.0 28.8
±mm 0.7 0.8 0.8 0.9 0.9 1.0 1.1 1.2 1.3 1.5 1.6 1.7 1.9 2.1 2.3 2.5 0.8 0.8 0.9 0.9 1.0 1.1 1.2
1.0
26.5
0.3
1.9
31.8
1.3
1.2
31.0
0.4
2.1
37.1
1.4
1.2
34.9
0.4
2.3
41.4
1.5
1.4
40.7
0.4
2.5
47.6
1.7
1.4
44.6
0.4
2.7
51.9
1.9
1.6
49.7
0.4
2.9
57.4
2.0
1.6
54.5
0.4
3.0
62.4
2.2
1.6
61.2
0.4
3.3
69.7
2.4
1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6 1.6 1.8 1.0 1.0 1.0 1.0 1.0 1.0 1.0
11.9 12.9 14.1 15.5 17.7 20.1 24.2 26.9 32.0 36.1 42.1 45.9 50.9 56.4 63.7 70.8 13.1 14.2 15.5 17.1 19.6 22.3 26.3
0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3
1.3 1.4 1.4 1.5 1.6 1.7 1.8 1.9 2.1 2.3 2.6 2.7 2.9 3.1 3.4 3.7 1.4 1.4 1.5 1.5 1.6 1.7 1.9
16.0 17.2 18.4 20.0 22.4 25.0 29.3 32.2 38.1 42.6 49.2 53.2 58.6 64.5 72.4 80.1 17.4 18.5 20.0 21.6 24.3 27.2 31.6
0.8 0.8 0.9 0.9 1.0 1.1 1.2 1.3 1.4 1.6 1.8 1.9 2.1 2.2 2.5 2.7 0.8 0.9 0.9 0.9 1.0 1.1 1.2
1.2
30.3
0.4
2.1
36.4
1.4
1.2
34.5
0.4
2.2
40.8
1.5
1.4
39.3
0.4
2.4
46.0
1.7
1.4
45.4
0.4
2.7
52.7
1.9
1.6
50.3
0.4
2.9
58.0
2.0
1.6
55.4
0.4
3.1
63.5
2.2
1.6
60.8
0.4
3.3
69.3
2.4
1.8
68.8
0.4
3.6
77.9
2.6
Conductor Insulation Resistance Resistance (at 20℃) (at 20℃) (Max.) (Min.) Ω/km 12.2 7.56 4.70 3.110 1.840 1.160 0.734 0.529 0.391 0.270 0.195 0.154 0.126 0.100 0.0762 0.0607 12.2 7.56 4.70 3.110 1.840 1.160 0.734 1.160 0.529 0.734 0.391 0.734 0.270 0.529 0.195 0.391 0.154 0.270 0.126 0.195 0.100 0.195 0.0762 0.154 12.2 7.56 4.70 3.110 1.840 1.160 0.734 0.529 0.391 0.270 0.195 0.154 0.126 0.100 0.0762 0.0607 12.2 7.56 4.70 3.110 1.840 1.160 0.734 1.160 0.529 0.734 0.391 0.734 0.270 0.529 0.195 0.391 0.154 0.270 0.126 0.195 0.100 0.195 0.0762 0.154
㏁-km 1,320 1,110 940 800 650 540 520 450 440 380 370 330 330 330 320 310 1,320 1,110 940 800 650 540 520 540 450 520 440 520 380 450 370 440 330 380 330 370 330 370 320 330 1,320 1,110 940 800 650 540 520 450 440 380 370 330 330 330 320 310 1,320 1,110 940 800 650 540 520 540 450 520 440 520 380 450 370 440 330 380 330 370 330 370 320 330
Test Voltage
Cable Weight
V/5min. 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500
kg/km 370 430 520 630 800 1,050 1,470 1,850 2,510 3,380 4,440 5,390 6,440 8,010 10,200 12,440 430 510 610 750 980 1,290 1,730
LV Power & Lighting Cable
mm2 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 1.5 2.5 4 6 10 16 25 16 35 25 50 25 70 35 95 50 120 70 150 95 185 95 240 120 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 1.5 2.5 4 6 10 16 25 16 35 25 50 25 70 35 95 50 120 70 150 95 185 95 240 120
Thickness Thickness Nominal of of dia. Insulation inner inner covering covering
2,220
Instrumentation & Communication Cable
3C+E 3C+E 3C+E 3C+E 3C+E 3C+E 3C Earth 3C Earth 3C Earth 3C Earth 3C Earth 3C Earth 3C Earth 3C Earth 3C Earth
Max. overall dia.
2,970 3,870 5,160 6,310 7,770 9,220 11,680
Earthing & Bonding wire
3
Min. No. of wires
430 510 610 750 980 1,290 1,830 2,320 3,230 4,240 5,700 6,850 8,310 10,200 13,030 16,060 500 590 720 880 1,160 1,540 2,110
VFD Cable
No.
Conductor Nominal Area
2,910 3,640 4,840
Technical Information
No. of Cores
HV Power Cable
0.6/1kV BFOU, 0.6/1kV BFCU, 0.6/1kV BFBU
6,420 7,950 9,630 11,540 14,760
Offshore Cable
25
Halogen free & Mud resistant Offshore cable
LV Power & Lighting Cable 0.6/1kV BFOU, 0.6/1kV BFCU, 0.6/1kV BFBU No. of Cores
No.
5 7 9 12 14 16 19 24 27 30 37 44 5 7 9 12 14 16 19 24 27 30 37 44 5 7 9 12 14 16 19 24 27 30 37 44 5 7 9 12 14 16 19 24 27 30 37 44
26
Conductor Nominal Area
Min. No. of wires
Max. overall dia.
mm2
EA
mm
1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 4 4 4 4 4 4 4 4 4 4 4 4
Offshore Cable
7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7
1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7
Thickness Thickness Nominal of of dia. Insulation inner inner covering covering mm
1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0
mm
1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.2 1.2 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.2 1.2 1.4 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.2 1.2 1.4
mm
12.3 13.4 15.7 17.8 18.8 19.9 21.0 24.8 25.4 26.4 29.4 33.2 13.1 14.3 16.8 19.0 20.1 21.3 22.5 26.6 28.0 29.1 31.5 35.6 14.2 15.5 18.3 20.7 21.9 23.2 24.5 29.8 30.5 31.7 34.3 39.2 15.5 17.0 20.1 22.8 24.1 25.5 27.0 32.8 33.6 34.9 37.8 43.2
Dia. of wire for armour mm
0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.4 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.4 0.4 0.4
Thickness Overall diameter of Nominal Tolersheath ance mm
1.3 1.4 1.5 1.6 1.6 1.6 1.7 1.8 1.9 1.9 2.0 2.2 1.4 1.4 1.5 1.6 1.7 1.7 1.8 1.9 2.0 2.0 2.1 2.3 1.4 1.5 1.6 1.7 1.7 1.8 1.8 2.0 2.1 2.1 2.2 2.4 1.5 1.5 1.7 1.8 1.8 1.9 1.9 2.2 2.2 2.3 2.4 2.6
mm
16.4 17.7 20.2 22.5 23.5 24.6 25.9 29.9 30.7 31.7 34.9 39.5 17.4 18.6 21.3 23.7 25.0 26.2 27.6 31.9 33.5 34.6 37.6 42.1 18.5 20.0 23.0 25.6 26.8 28.3 29.6 35.3 36.6 37.8 40.6 45.9 20.0 21.5 25.0 27.9 29.2 30.8 32.3 39.1 39.9 41.4 44.5 50.3
±mm
0.8 0.8 0.9 1.0 1.0 1.0 1.1 1.2 1.2 1.3 1.3 1.5 0.8 0.9 0.9 1.0 1.1 1.1 1.1 1.3 1.3 1.3 1.4 1.6 0.9 0.9 1.0 1.1 1.1 1.1 1.2 1.4 1.4 1.4 1.5 1.7 0.9 0.9 1.1 1.1 1.2 1.2 1.3 1.5 1.5 1.5 1.6 1.8
Conductor Insulation Resistance Resistance (at 20℃) (at 20℃) (Max.) (Min.)
Test Voltage
Cable Weight
Ω/km
㏁-km
V/5min.
kg/km
18.2 18.2 18.2 18.2 18.2 18.2 18.2 18.2 18.2 18.2 18.2 18.2 12.2 12.2 12.2 12.2 12.2 12.2 12.2 12.2 12.2 12.2 12.2 12.2 7.56 7.56 7.56 7.56 7.56 7.56 7.56 7.56 7.56 7.56 7.56 7.56 4.70 4.70 4.70 4.70 4.70 4.70 4.70 4.70 4.70 4.70 4.70 4.70
1,490 1,490 1,490 1,490 1,490 1,490 1,490 1,490 1,490 1,490 1,490 1,490 1,320 1,320 1,320 1,320 1,320 1,320 1,320 1,320 1,320 1,320 1,320 1,320 1,110 1,110 1,110 1,110 1,110 1,110 1,110 1,110 1,110 1,110 1,110 1,110 940 940 940 940 940 940 940 940 940 940 940 940
3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500
420 500 610 750 820 900 1,010 1,240 1,350 1,450 1,790 2,200 480 570 700 850 950 1,050 1,180 1,460 1,670 1,800 2,190 2,580 560 680 840 1,040 1,150 1,280 1,440 1,890 2,140 2,310 2,710 3,250 680 830 1,040 1,300 1,450 1,620 1,830 2,500 2,700 2,940 3,460 4,160
Instrumentation & Communication Cable
250V RU(c)
28 ~ 30
250V RU(i)
31 ~ 33
250V RU(i&c)
34 ~ 36
250V RFOU(c), RFCU(c), RFBU(c)
37 ~ 39
250C RFOU(i), RFCU(i), RFBU(i)
40 ~ 42
250V RFOU(i&c), RFCU(i&c), RFBU(i&c)
43 ~ 45
250V BU(c)
46 ~ 48
250V BU(i)
49 ~ 51
250V BU(i&c)
52 ~ 54
250V BFOU(c), BFCU(c), BFBU(c)
55 ~ 57
250C BFOU(i), BFCU(i), BFBU(i)
58 ~ 60
250V BFOU(i&c), BFCU(i&c), BFBU(i&c)
61 ~ 63
Halogen free & Mud resistant Offshore cable
Instrumentation & Communication Cable
Cable Designation (S12) 250V RU(c)
Application Standard - Design guide
: NEK-606 & IEC 60092-376
- Flame retardant
: IEC 60332-1 &
250V RU(c)
IEC 60332-3 Category A
- Halogen content
: IEC 60754-1, 0.5%↓
- Cold bend / impact
: CSA 22.2 No.03 (-40℃/-35℃)
- Mud resistant
: NEK-606 (Mud type only)
- Smoke light transmittance
: IEC 61034, 60%↑
- Sunlight (UV) resistant
: UL 1581
Construction Sectional view
Classification
Code
Conductor Insulation
Construction detail - Stranded tinned annealed copper wires as per IEC 60228, Class 2
R
Twisting
- HF EPR as per IEC 60092-351 - Two/Three Insulated cores shall be twisted together to form a pair/Triad - Twisted pairs / triads shall be cabled - Flame retardant & non-hygroscopic fillers may be used
Cabling
- Suitable tape(s) may be applied on the cabled core - A Filler may be applied to obtain a circular Cable
Collective screen
(c)
Sheath
U
- CU/PS or AL/PS tape + Tinned copper drain wire - SHF2 or SHF Mud as per IEC 60092-359 - Outer sheath color : Grey (Non-IS Type) or Blue (IS Type) - Each Pair / Triad : Core color
Core identification
① Pair : Black, Light blue
② Triad : Black, Light blue, Brown
- Multi Pairs / Triads : Number printing on the insulation or numbered tape Note. Flexible cable (Class5 Conductor) can be supplied
28
Offshore Cable
Instrumentation & Communication Cable
• •
●
• • •
NEK-606 (2009), IEC 60092-350, 353, 354, 376
mm
7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7
1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2
Thickness of sheath
mm
mm
0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7
1.0 1.1 1.1 1.2 1.2 1.3 1.3 1.3 1.4 1.4 1.4 1.5 1.5 1.6 1.8 1.0 1.1 1.2 1.2 1.3 1.3 1.3 1.3 1.4 1.5 1.5 1.5 1.6 1.7 1.8 1.0 1.2 1.3 1.3 1.4 1.4 1.4 1.5 1.6 1.6 1.6 1.7 1.7 1.9 2.1 1.1 1.3 1.3 1.4 1.4 1.5 1.5 1.5 1.7 1.7 1.7 1.8 1.9 2.0 2.2
Overall diameter Nominal
Tolerance
mm
±mm
7.0 10.4 11.1 12.0 13.4 14.5 14.5 15.4 17.5 18.2 18.8 20.4 21.3 24.3 27.9 7.4 11.1 12.1 12.8 14.5 15.5 15.5 16.5 18.7 19.7 20.4 21.9 23.1 26.3 30.2 8.4 13.0 14.1 15.0 17.0 18.2 18.2 19.6 22.2 23.1 24.0 26.0 27.2 31.4 36.0 9.4 14.6 15.6 16.8 18.8 20.4 20.4 21.8 24.9 25.9 26.9 29.4 30.9 35.2 40.4
0.5 0.6 0.6 0.7 0.7 0.7 0.7 0.8 0.8 0.8 0.9 0.9 0.9 1.0 1.1 0.5 0.6 0.7 0.7 0.7 0.8 0.8 0.8 0.9 0.9 0.9 1.0 1.0 1.1 1.2 0.6 0.7 0.7 0.8 0.8 0.8 0.8 0.9 1.0 1.0 1.0 1.1 1.1 1.2 1.4 0.6 0.7 0.8 0.8 0.9 0.9 0.9 1.0 1.0 1.1 1.1 1.2 1.2 1.4 1.5
Conductor Resistance (at 20℃) (Max.)
Insulation Resistance (at 20℃) (Min.)
Test Voltage
Cable Weight Approx.
Ω/km
㏁-km
V/5min.
kg/km
26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02
1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 850 850 850 850 850 850 850 850 850 850 850 850 850 850 850
1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500
80 140 170 210 240 280 310 340 420 470 530 600 680 850 1,110 90 160 200 240 290 330 360 400 490 570 640 720 830 1,030 1,350 110 210 270 320 390 450 490 560 680 780 870 1,000 1,140 1,460 1,900 150 270 340 430 510 600 660 740 930 1,060 1,200 1,390 1,610 2,000 2,620
Offshore Cable
LV Power & Lighting Cable
EA
0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5
Thickness of Insulation
Instrumentation & Communication Cable
mm2
Max. overall dia.
Earthing & Bonding wire
1P 2P 3P 4P 5P 6P 7P 8P 10P 12P 14P 16P 19P 24P 32P 1P 2P 3P 4P 5P 6P 7P 8P 10P 12P 14P 16P 19P 24P 32P 1P 2P 3P 4P 5P 6P 7P 8P 10P 12P 14P 16P 19P 24P 32P 1P 2P 3P 4P 5P 6P 7P 8P 10P 12P 14P 16P 19P 24P 32P
Max. No. of wires
VFD Cable
No.
Conductor Nominal Area
Technical Information
No. of Pairs
HV Power Cable
250V RU(c)
29
Halogen free & Mud resistant Offshore cable
Instrumentation & Communication Cable 250V RU(c) No. of Triads
No.
1T 2T 3T 4T 5T 6T 7T 8T 10T 12T 14T 16T 19T 24T 32T 1T 2T 3T 4T 5T 6T 7T 8T 10T 12T 14T 16T 19T 24T 32T 1T 2T 3T 4T 5T 6T 7T 8T 10T 12T 14T 16T 19T 24T 32T 1T 2T 3T 4T 5T 6T 7T 8T 10T 12T 14T 16T 19T 24T 32T
30
Conductor Nominal Area
Max. No. of wires
Max. overall dia.
mm2
EA
mm
0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5
Offshore Cable
7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7
1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2
Thickness of Insulation
Thickness of sheath
mm
mm
0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7
1.0 1.2 1.2 1.2 1.3 1.4 1.4 1.4 1.5 1.6 1.6 1.6 1.7 1.8 2.0 1.0 1.2 1.2 1.3 1.3 1.4 1.4 1.5 1.6 1.6 1.6 1.7 1.8 1.9 2.1 1.1 1.3 1.3 1.4 1.4 1.5 1.5 1.6 1.7 1.8 1.8 1.9 2.0 2.1 2.4 1.1 1.3 1.4 1.4 1.5 1.6 1.6 1.7 1.8 1.9 2.0 2.0 2.2 2.3 2.6
Overall diameter Nominal
Tolerance
mm
±mm
7.4 11.6 12.3 13.5 15.1 17.1 17.1 18.3 20.8 22.2 23.1 24.5 26.6 29.7 34.3 7.8 12.3 13.1 14.5 16.0 18.2 18.2 19.7 22.4 23.6 24.6 26.4 28.6 32.0 36.9 9.1 14.5 15.4 17.1 18.9 21.5 21.5 23.2 26.4 28.1 29.5 31.5 34.2 38.0 44.0 10.0 16.0 17.3 19.0 21.3 24.2 24.2 26.1 30.0 31.9 33.4 35.5 38.7 43.0 49.8
0.5 0.6 0.7 0.7 0.8 0.8 0.8 0.8 0.9 1.0 1.0 1.0 1.1 1.2 1.3 0.5 0.7 0.7 0.7 0.8 0.8 0.8 0.9 1.0 1.0 1.0 1.1 1.2 1.3 1.4 0.6 0.7 0.8 0.8 0.9 0.9 0.9 1.0 1.1 1.1 1.2 1.2 1.3 1.4 1.6 0.6 0.8 0.8 0.9 0.9 1.0 1.0 1.1 1.2 1.3 1.3 1.4 1.5 1.6 1.8
Conductor Resistance (at 20℃) (Max.)
Insulation Resistance (at 20℃) (Min.)
Test Voltage
Cable Weight Approx.
Ω/km
㏁-km
V/5min.
kg/km
26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02
1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 850 850 850 850 850 850 850 850 850 850 850 850 850 850 850
1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500
100 180 220 270 330 390 430 470 580 680 760 850 1,000 1,250 1,630 110 210 260 320 380 460 500 570 710 810 910 1,030 1,210 1,510 1,980 140 270 340 430 520 620 680 780 960 1,120 1,290 1,460 1,710 2,100 2,780 180 350 460 570 700 840 930 1,070 1,340 1,560 1,790 2,010 2,380 2,930 3,880
Instrumentation & Communication Cable
• •
●
• • •
HV Power Cable
NEK-606 (2009), IEC 60092-350, 353, 354, 376
Cable Designation (S11) LV Power & Lighting Cable
250V RU(i)
Application Standard - Design guide
: NEK-606 & IEC 60092-376
- Flame retardant
: IEC 60332-1 & IEC 60332-3 Category A
- Halogen content
: IEC 60754-1, 0.5%↓
- Cold bend / impact
: CSA 22.2 No.03 (-40℃/-35℃)
- Mud resistant
: NEK-606 (Mud type only)
- Smoke light transmittance
: IEC 61034, 60%↑
- Sunlight (UV) resistant
: UL 1581
Instrumentation & Communication Cable
250V RU(i)
Sectional view
Classification
Code
Conductor Insulation
Construction detail - Stranded tinned annealed copper wires as per IEC 60228, Class 2
R
Twisting Individual screen
Earthing & Bonding wire
Construction
- HF EPR as per IEC 60092-351 - Two/Three Insulated cores shall be twisted together to form a pair/Triad
(i)
- CU/PS or AL/PS tape + Tinned copper drain wire - Twisted pairs / triads shall be cabled - Flame retardant & non-hygroscopic fillers may be used
Cabling
- Suitable tape(s) may be applied on the cabled core - A Filler may be applied to obtain a circular Cable U
- SHF2 or SHF Mud as per IEC 60092-359
VFD Cable
Sheath
- Outer sheath color : Grey (Non-IS Type) or Blue (IS Type) - Each Pair / Triad : Core color
Core identification
① Pair : Black, Light blue
② Triad : Black, Light blue, Brown
- Multi Pairs / Triads : Number printing on the insulation or numbered tape
Technical Information
Note. Flexible cable (Class5 Conductor) can be supplied
Offshore Cable
31
Halogen free & Mud resistant Offshore cable
Instrumentation & Communication Cable 250V RU(i) No. of Pairs
No.
1P 2P 3P 4P 5P 6P 7P 8P 10P 12P 14P 16P 19P 24P 32P 1P 2P 3P 4P 5P 6P 7P 8P 10P 12P 14P 16P 19P 24P 32P 1P 2P 3P 4P 5P 6P 7P 8P 10P 12P 14P 16P 19P 24P 32P 1P 2P 3P 4P 5P 6P 7P 8P 10P 12P 14P 16P 19P 24P 32P
32
Conductor Nominal Area
Max. No. of wires
Max. overall dia.
mm2
EA
mm
0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5
Offshore Cable
7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7
1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2
Thickness of Insulation
Thickness of sheath
mm
mm
0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7
1.0 1.1 1.2 1.2 1.3 1.3 1.3 1.4 1.4 1.5 1.5 1.6 1.6 1.7 1.8 1.0 1.2 1.2 1.2 1.3 1.3 1.3 1.4 1.5 1.5 1.6 1.6 1.7 1.8 1.9 1.0 1.2 1.3 1.3 1.4 1.4 1.4 1.5 1.6 1.7 1.7 1.8 1.8 2.0 2.1 1.1 1.3 1.3 1.4 1.5 1.5 1.5 1.6 1.7 1.8 1.8 1.9 1.9 2.2 2.3
Overall diameter Nominal
Tolerance
mm
±mm
7.0 11.1 11.9 13.0 14.7 15.2 15.2 16.8 19.0 20.0 20.9 22.6 23.1 27.0 29.6 7.4 12.0 12.7 13.8 15.6 16.2 16.2 17.9 20.5 21.3 22.6 24.2 24.9 29.3 31.9 8.4 13.7 14.7 16.1 18.2 18.9 18.9 20.9 24.0 25.1 26.4 28.5 29.3 34.4 37.5 9.4 15.3 16.2 18.0 20.3 21.1 21.1 23.4 26.8 28.0 29.7 32.0 32.7 38.6 42.0
0.5 0.6 0.7 0.7 0.7 0.8 0.8 0.8 0.9 0.9 0.9 1.0 1.0 1.1 1.2 0.5 0.7 0.7 0.7 0.8 0.8 0.8 0.8 0.9 0.9 1.0 1.0 1.0 1.2 1.3 0.6 0.7 0.7 0.8 0.8 0.9 0.9 0.9 1.0 1.1 1.1 1.2 1.2 1.3 1.4 0.6 0.8 0.8 0.8 0.9 0.9 0.9 1.0 1.1 1.1 1.2 1.3 1.3 1.5 1.6
Conductor Resistance (at 20℃) (Max.)
Insulation Resistance (at 20℃) (Min.)
Test Voltage
Cable Weight Approx.
Ω/km
㏁-km
V/5min.
kg/km
26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02
1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 850 850 850 850 850 850 850 850 850 850 850 850 850 850 850
1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500
40 70 110 140 170 200 240 270 340 400 470 540 630 800 1,060 90 180 230 280 350 400 440 510 630 720 830 930 1,080 1,380 1,760 120 230 300 370 450 520 570 660 820 960 1,080 1,240 1,430 1,820 2,330 150 290 380 490 600 690 760 880 1,090 1,280 1,470 1,680 1,920 2,470 3,170
Instrumentation & Communication Cable
• •
●
• • •
NEK-606 (2009), IEC 60092-350, 353, 354, 376
mm
7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7
1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2
Thickness of sheath
mm
mm
0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7
1.0 1.2 1.2 1.3 1.3 1.4 1.4 1.4 1.5 1.6 1.6 1.7 1.8 1.9 2.1 1.0 1.2 1.2 1.3 1.4 1.4 1.4 1.5 1.6 1.7 1.7 1.8 1.8 2.0 2.2 1.1 1.3 1.3 1.4 1.5 1.6 1.6 1.6 1.8 1.8 1.9 1.9 2.0 2.2 2.4 1.1 1.3 1.4 1.5 1.5 1.7 1.7 1.7 1.9 1.9 2.0 2.1 2.2 2.4 2.6
Overall diameter Nominal
Tolerance
mm
±mm
7.4 12.0 12.8 14.2 15.7 17.9 17.9 19.1 21.7 23.2 24.2 25.8 28.0 31.4 36.2 7.8 12.8 13.5 15.1 16.9 19.0 19.0 20.5 23.3 24.9 25.9 27.7 30.0 33.6 38.8 9.1 14.9 15.8 17.6 19.7 22.4 22.4 24.0 27.6 29.3 30.8 32.7 35.5 39.6 45.7 10.0 16.5 17.7 19.7 21.9 25.1 25.1 26.9 31.1 32.9 34.5 36.9 40.0 44.6 51.4
0.5 0.7 0.7 0.7 0.8 0.8 0.8 0.9 1.0 1.0 1.0 1.1 1.1 1.2 1.4 0.5 0.7 0.7 0.8 0.8 0.9 0.9 0.9 1.0 1.0 1.1 1.1 1.2 1.3 1.5 0.6 0.7 0.8 0.8 0.9 1.0 1.0 1.0 1.1 1.2 1.2 1.3 1.4 1.5 1.7 0.6 0.8 0.8 0.9 1.0 1.1 1.1 1.1 1.2 1.3 1.3 1.4 1.5 1.6 1.8
Conductor Resistance (at 20℃) (Max.)
Insulation Resistance (at 20℃) (Min.)
Test Voltage
Cable Weight Approx.
Ω/km
㏁-km
V/5min.
kg/km
26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02
1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 850 850 850 850 850 850 850 850 850 850 850 850 850 850 850
1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500
150 280 340 420 490 590 630 700 850 980 1,100 1,230 1,430 1,760 2,360 110 220 280 360 450 520 580 660 820 970 1,090 1,250 1,460 1,830 2,410 150 290 370 480 590 710 780 880 1,110 1,300 1,490 1,670 1,960 2,460 3,220 190 370 500 640 770 950 1,060 1,190 1,510 1,750 2,020 2,290 2,690 3,370 4,420
Offshore Cable
LV Power & Lighting Cable
EA
0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5
Thickness of Insulation
Instrumentation & Communication Cable
mm2
Max. overall dia.
Earthing & Bonding wire
1T 2T 3T 4T 5T 6T 7T 8T 10T 12T 14T 16T 19T 24T 32T 1T 2T 3T 4T 5T 6T 7T 8T 10T 12T 14T 16T 19T 24T 32T 1T 2T 3T 4T 5T 6T 7T 8T 10T 12T 14T 16T 19T 24T 32T 1T 2T 3T 4T 5T 6T 7T 8T 10T 12T 14T 16T 19T 24T 32T
Max. No. of wires
VFD Cable
No.
Conductor Nominal Area
Technical Information
No. of Triads
HV Power Cable
250V RU(i)
33
Halogen free & Mud resistant Offshore cable
Instrumentation & Communication Cable
Cable Designation 250V RU(i&c)
Application Standard - Design guide
: NEK-606 & IEC 60092-376
- Flame retardant
: IEC 60332-1 &
250V RU(i&c)
IEC 60332-3 Category A
- Halogen content
: IEC 60754-1, 0.5%↓
- Cold bend / impact
: CSA 22.2 No.03 (-40℃/-35℃)
- Mud resistant
: NEK-606 (Mud type only)
- Smoke light transmittance
: IEC 61034, 60%↑
- Sunlight (UV) resistant
: UL 1581
Construction Sectional view
Classification
Code
Conductor Insulation
R
Twisting Individual screen
Construction detail - Stranded tinned annealed copper wires as per IEC 60228, Class 2 - HF EPR as per IEC 60092-351 - Two/Three Insulated cores shall be twisted together to form a pair/Triad
(i)
- CU/PS or AL/PS tape + Tinned copper drain wire - Twisted pairs / triads shall be cabled - Flame retardant & non-hygroscopic fillers may be used
Cabling
- Suitable tape(s) may be applied on the cabled core - A Filler may be applied to obtain a circular Cable
Collective screen
(c)
Sheath
U
- CU/PS or AL/PS tape + Tinned copper drain wire - SHF2 or SHF Mud as per IEC 60092-359 - Outer sheath color : Grey (Non-IS Type) or Blue (IS Type) - Each Pair / Triad : Core color
Core identification
① Pair : Black, Light blue
② Triad : Black, Light blue, Brown
- Multi Pairs / Triads : Number printing on the insulation or numbered tape Note. Flexible cable (Class5 Conductor) can be supplied
34
Offshore Cable
Instrumentation & Communication Cable
• •
●
• • •
NEK-606 (2009), IEC 60092-350, 353, 354, 376
mm
7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7
1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2
Thickness of sheath
mm
mm
0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7
1.2 1.2 1.2 1.3 1.3 1.3 1.4 1.4 1.5 1.5 1.6 1.6 1.7 1.8 1.2 1.2 1.3 1.3 1.3 1.3 1.4 1.5 1.5 1.6 1.6 1.7 1.8 1.9 1.2 1.3 1.3 1.4 1.4 1.4 1.5 1.6 1.7 1.7 1.8 1.8 2.0 2.1 1.3 1.3 1.4 1.5 1.5 1.5 1.6 1.7 1.8 1.8 1.9 1.9 2.2 2.3
Overall diameter Nominal
Tolerance
mm
±mm
11.4 12.0 13.1 14.8 15.3 15.3 16.9 19.1 20.1 21.0 22.7 23.2 27.1 29.7 12.1 12.8 14.1 15.7 16.3 16.3 18.0 20.6 21.4 22.7 24.3 25.0 29.4 32.0 13.8 14.8 16.2 18.3 19.0 19.0 21.0 24.1 25.2 26.5 28.6 29.4 34.5 37.6 15.4 16.3 18.1 20.4 21.2 21.2 23.5 26.9 28.1 29.8 32.1 32.8 38.7 42.1
0.6 0.7 0.7 0.7 0.8 0.8 0.8 0.9 0.9 0.9 1.0 1.0 1.1 1.2 0.7 0.7 0.7 0.8 0.8 0.8 0.8 0.9 0.9 1.0 1.0 1.1 1.2 1.3 0.7 0.7 0.8 0.8 0.9 0.9 0.9 1.0 1.1 1.1 1.2 1.2 1.3 1.4 0.8 0.8 0.8 0.9 0.9 0.9 1.0 1.1 1.1 1.2 1.3 1.3 1.5 1.6
Conductor Resistance (at 20℃) (Max.)
Insulation Resistance (at 20℃) (Min.)
Test Voltage
Cable Weight Approx.
Ω/km
㏁-km
V/5min.
kg/km
26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02
1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 850 850 850 850 850 850 850 850 850 850 850 850 850 850
1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500
170 210 260 310 350 380 440 530 620 700 800 900 1,130 1,470 200 250 310 370 420 460 530 650 740 860 960 1,110 1,410 1,800 240 320 390 470 540 590 680 840 980 1,110 1,270 1,460 1,850 2,360 320 400 510 620 710 790 910 1,120 1,310 1,510 1,710 1,960 2,510 3,210
Offshore Cable
LV Power & Lighting Cable
EA
0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5
Thickness of Insulation
Instrumentation & Communication Cable
mm2
Max. overall dia.
Earthing & Bonding wire
2P 3P 4P 5P 6P 7P 8P 10P 12P 14P 16P 19P 24P 32P 2P 3P 4P 5P 6P 7P 8P 10P 12P 14P 16P 19P 24P 32P 2P 3P 4P 5P 6P 7P 8P 10P 12P 14P 16P 19P 24P 32P 2P 3P 4P 5P 6P 7P 8P 10P 12P 14P 16P 19P 24P 32P
Max. No. of wires
VFD Cable
No.
Conductor Nominal Area
Technical Information
No. of Pairs
HV Power Cable
250V RU(i&c)
35
Halogen free & Mud resistant Offshore cable
Instrumentation & Communication Cable 250V RU(i&c) No. of Triads
No.
2T 3T 4T 5T 6T 7T 8T 10T 12T 14T 16T 19T 24T 32T 2T 3T 4T 5T 6T 7T 8T 10T 12T 14T 16T 19T 24T 32T 2T 3T 4T 5T 6T 7T 8T 10T 12T 14T 16T 19T 24T 32T 2T 3T 4T 5T 6T 7T 8T 10T 12T 14T 16T 19T 24T 32T
36
Conductor Nominal Area
Max. No. of wires
Max. overall dia.
mm2
EA
mm
0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5
Offshore Cable
7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7
1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2
Thickness of Insulation
Thickness of sheath
mm
mm
0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7
1.2 1.2 1.3 1.3 1.4 1.4 1.4 1.5 1.6 1.6 1.7 1.8 1.9 2.1 1.2 1.2 1.3 1.4 1.4 1.4 1.5 1.6 1.7 1.7 1.8 1.8 2.0 2.2 1.3 1.3 1.4 1.5 1.6 1.6 1.6 1.8 1.8 1.9 1.9 2.0 2.2 2.4 1.4 1.4 1.5 1.6 1.7 1.7 1.7 1.9 2.0 2.0 2.1 2.2 2.4 2.6
Overall diameter Nominal
Tolerance
mm
±mm
12.1 12.9 14.3 15.8 18.0 18.0 19.2 21.8 23.3 24.3 25.9 28.1 31.5 36.3 12.9 13.6 15.2 17.0 19.1 19.1 20.6 23.4 25.0 26.0 27.8 30.1 33.7 38.9 15.0 15.9 17.7 19.8 22.5 22.5 24.1 27.7 29.4 30.9 32.8 35.6 39.7 45.8 16.8 17.8 19.8 22.2 25.2 25.2 27.0 31.2 33.2 34.6 37.0 40.1 44.7 51.5
0.7 0.7 0.7 0.8 0.8 0.8 0.9 1.0 1.0 1.0 1.1 1.1 1.2 1.4 0.7 0.7 0.8 0.8 0.9 0.9 0.9 1.0 1.1 1.1 1.1 1.2 1.3 1.5 0.8 0.8 0.8 0.9 1.0 1.0 1.0 1.1 1.2 1.2 1.3 1.4 1.5 1.7 0.8 0.8 0.9 1.0 1.1 1.1 1.1 1.2 1.3 1.3 1.4 1.5 1.6 1.8
Conductor Resistance (at 20℃) (Max.)
Insulation Resistance (at 20℃) (Min.)
Test Voltage
Cable Weight Approx.
Ω/km
㏁-km
V/5min.
kg/km
26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02
1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 850 850 850 850 850 850 850 850 850 850 850 850 850 850
1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500
200 260 320 380 460 510 570 700 820 920 1,050 1,230 1,540 2,010 240 300 380 470 550 600 690 850 990 1,120 1,270 1,490 1,870 2,450 310 390 500 610 730 810 900 1,140 1,330 1,520 1,700 2,000 2,490 3,270 400 520 660 810 980 1,080 1,220 1,550 1,810 2,050 2,330 2,730 3,410 4,470
Instrumentation & Communication Cable
• •
●
• • •
HV Power Cable
NEK-606 (2009), IEC 60092-350, 353, 354, 376
Cable Designation (S2, S2/S6) LV Power & Lighting Cable
250V RFOU(c), RFCU(c), RFBU(c)
Application Standard - Design guide
: NEK-606 & IEC 60092-376
- Flame retardant
: IEC 60332-1 & IEC 60332-3 Category A
- Halogen content
: IEC 60754-1, 0.5%↓
- Cold bend / impact
: CSA 22.2 No.03 (-40℃/-35℃)
- Mud resistant
: NEK-606 (Mud type only)
- Smoke light transmittance
: IEC 61034, 60%↑
- Sunlight (UV) resistant
: UL 1581
Instrumentation & Communication Cable
250V RFOU(c)
Sectional view
Classification
Code
Conductor Insulation
Earthing & Bonding wire
Construction Construction detail - Stranded tinned annealed copper wires as per IEC 60228, Class 2 R
Twisting
- HF EPR as per IEC 60092-351 - Two/Three Insulated cores shall be twisted together to form a pair/Triad - Twisted pairs / triads shall be cabled - Flame retardant & non-hygroscopic fillers may be used
Cabling
- Suitable tape(s) may be applied on the cabled core
Inner covering Armor Sheath
(c)
- CU/PS or AL/PS tape + Tinned copper drain wire
F
- Flame retardant halogen free thermoset compound
O
- Braid of tinned copper wire (O) / bronze wire (B) /galvanized steel wire (C)
(B,C) U
VFD Cable
- A Filler may be applied to obtain a circular Cable Collective screen
- A suitable separator tape(s) may be applied under/over the armor - SHF2 or SHF Mud as per IEC 60092-359 - Outer sheath color : Grey (Non-IS Type) or Blue (IS Type) - Each Pair / Triad : Core color
Core identification
① Pair : Black, Light blue
② Triad : Black, Light blue, Brown
Technical Information
- Multi Pairs / Triads : Number printing on the insulation or numbered tape Note. Flexible cable (Class5 Conductor) can be supplied
Offshore Cable
37
Halogen free & Mud resistant Offshore cable
Instrumentation & Communication Cable 250V RFOU(c), 250V RFCU(c), 250V RFBU(c) No. of Pairs
Conductor Nominal Area
Max. No. of wires
Max. overall dia.
No.
mm2
EA
mm
1P 2P 3P 4P 5P 6P 7P 8P 10P 12P 14P 16P 19P 24P 32P 1P 2P 3P 4P 5P 6P 7P 8P 10P 12P 14P 16P 19P 24P 32P 1P 2P 3P 4Pi 5P 6P 7P 8P 10P 12P 14P 16P 19P 24P 32P 1P 2P 3P 4P 5P 6P 7P 8P 10P 12P 14P 16P 19P 24P 32P
0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5
38
Offshore Cable
7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7
1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2
Thickness Thickness Nominal of of dia. Insulation inner inner covering covering mm
0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7
mm
1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.2 1.4
mm
6.8 10.0 10.7 11.4 12.8 13.7 13.7 14.6 16.5 17.2 17.8 19.2 20.1 22.9 26.1 7.2 10.7 11.5 12.2 13.7 14.7 14.7 15.7 17.7 18.5 19.2 20.7 21.7 24.7 29.0 8.2 12.4 13.3 14.2 16.0 17.2 17.2 18.4 20.8 21.7 22.6 24.4 25.6 30.0 34.2 9.0 13.8 14.8 15.8 17.8 19.2 19.2 20.6 23.3 24.3 25.3 28.2 29.5 33.6 38.8
Dia. of wire for armour mm
0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4
Thickness Overall diameter of Nominal Tolersheath ance mm
1.1 1.3 1.3 1.3 1.4 1.4 1.4 1.4 1.5 1.5 1.6 1.6 1.7 1.8 1.9 1.1 1.3 1.3 1.3 1.4 1.4 1.4 1.5 1.6 1.6 1.6 1.7 1.7 1.8 2.0 1.2 1.3 1.4 1.4 1.5 1.5 1.5 1.6 1.7 1.7 1.8 1.8 1.9 2.1 2.2 1.2 1.4 1.4 1.5 1.6 1.6 1.6 1.7 1.8 1.8 1.9 2.0 2.0 2.2 2.4
mm
10.5 14.1 14.8 15.5 17.1 18.0 18.0 18.9 21.0 21.7 22.5 23.9 25.0 28.0 31.4 10.9 14.8 15.6 16.3 18.0 19.0 19.0 20.2 22.4 23.2 23.9 25.6 26.6 29.8 34.5 12.1 16.5 17.6 18.5 20.5 21.7 21.7 23.1 25.7 26.6 27.7 29.5 30.9 35.7 40.5 12.9 18.1 19.1 20.3 22.5 23.9 23.9 25.5 28.4 29.4 30.6 33.7 35.0 39.9 45.5
±mm
0.6 0.7 0.7 0.8 0.8 0.8 0.8 0.9 0.9 1.0 1.0 1.0 1.1 1.1 1.2 0.6 0.7 0.8 0.8 0.8 0.9 0.9 0.9 1.0 1.0 1.0 1.1 1.1 1.2 1.3 0.7 0.8 0.8 0.9 0.9 1.0 1.0 1.0 1.1 1.1 1.1 1.2 1.2 1.4 1.5 0.7 0.8 0.9 0.9 1.0 1.0 1.0 1.1 1.2 1.2 1.2 1.3 1.4 1.5 1.7
Conductor Insulation Resistance Resistance (at 20℃) (at 20℃) (Max.) (Min.)
Test Voltage
Cable Weight Approx.
Ω/km
㏁-km
V/5min.
kg/km
26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02
1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 850 850 850 850 850 850 850 850 850 850 850 850 850 850 850
1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500
200 300 340 380 450 490 520 560 660 730 800 880 980 1,190 1,470 210 340 380 430 500 550 580 650 760 840 920 1,030 1,140 1,370 1,820 250 400 470 530 630 700 740 820 980 1,090 1,210 1,340 1,510 1,940 2,510 290 480 570 660 780 880 940 1,050 1,250 1,400 1,560 1,850 2,070 2,630 3,380
Instrumentation & Communication Cable
• •
●
• • •
NEK-606 (2009), IEC 60092-350, 353, 354, 376
mm2
EA
mm
1T 2T 3T 4T 5T 6T 7T 8T 10T 12T 14T 16T 19T 24T 32T 1T 2T 3T 4T 5T 6T 7T 8T 10T 12T 14T 16T 19T 24T 32T 1T 2T 3T 4T 5T 6T 7T 8T 10T 12T 14T 16T 19T 24T 32T 1T 2T 3T 4T 5T 6T 7T 8T 10T 12T 14T 16T 19T 24T 32T
0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5
7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7
1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2
mm
0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7
mm
1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.2 1.2 1.4 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.2 1.2 1.2 1.4 1.4
mm
7.2 11.0 11.7 12.9 14.3 16.1 16.1 17.3 19.6 20.8 21.7 23.1 25.0 28.5 32.7 7.6 11.7 12.5 13.7 15.2 17.2 17.2 18.5 21.0 22.2 23.2 24.8 26.8 30.6 35.1 8.7 13.7 14.6 16.1 17.9 20.3 20.3 21.8 24.8 26.3 28.3 30.1 32.6 36.2 42.0 9.6 15.2 16.3 18.0 20.1 22.8 22.8 24.5 28.8 30.5 31.8 33.9 36.7 41.2 47.4
Dia. of wire for armour mm
0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.4 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.4 0.4 0.4 0.4
Thickness Overall diameter of Nominal Tolersheath ance mm
1.1 1.3 1.3 1.4 1.4 1.5 1.5 1.5 1.6 1.7 1.7 1.8 1.9 2.0 2.2 1.2 1.3 1.4 1.4 1.5 1.5 1.5 1.6 1.7 1.7 1.8 1.8 1.9 2.1 2.3 1.2 1.4 1.4 1.5 1.6 1.7 1.7 1.7 1.8 1.9 2.0 2.1 2.2 2.3 2.5 1.2 1.5 1.5 1.6 1.7 1.8 1.8 1.8 2.0 2.1 2.1 2.2 2.3 2.5 2.8
mm
10.9 15.1 15.8 17.2 18.6 20.6 20.6 21.8 24.3 25.7 26.6 28.2 30.3 34.0 39.0 11.5 15.8 16.8 18.0 19.7 21.7 21.7 23.2 25.9 27.1 28.3 29.9 32.1 36.7 41.6 12.6 18.0 18.9 20.6 22.6 25.2 25.2 26.7 29.9 31.6 33.8 36.2 38.9 42.7 48.9 13.5 19.7 20.8 22.7 25.0 27.9 27.9 29.6 34.3 36.6 37.9 40.2 43.2 48.1 54.9
Conductor Insulation Resistance Resistance (at 20℃) (at 20℃) (Max.) (Min.)
Test Voltage
Cable Weight Approx.
±mm
Ω/km
㏁-km
V/5min.
kg/km
0.6 0.8 0.8 0.8 0.9 0.9 0.9 1.0 1.0 1.1 1.1 1.1 1.2 1.3 1.5 0.6 0.8 0.8 0.8 0.9 1.0 1.0 1.0 1.1 1.1 1.1 1.2 1.3 1.4 1.5 0.7 0.8 0.9 0.9 1.0 1.1 1.1 1.1 1.2 1.2 1.3 1.4 1.5 1.6 1.8 0.7 0.9 0.9 1.0 1.1 1.1 1.1 1.2 1.3 1.4 1.4 1.5 1.6 1.7 1.9
26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02
1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 850 850 850 850 850 850 850 850 850 850 850 850 850 850 850
1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500
220 350 400 470 540 630 670 730 870 980 1,070 1,190 1,360 1,710 2,240 240 390 460 530 620 710 760 840 1,000 1,120 1,250 1,380 1,580 2,090 2,620 290 480 570 670 790 930 990 1,090 1,310 1,490 1,750 2,030 2,320 2,770 3,560 340 590 710 850 1,010 1,180 1,270 1,410 1,800 2,140 2,370 2,640 3,020 3,730 4,770
Offshore Cable
LV Power & Lighting Cable
No.
Thickness Thickness Nominal of of dia. Insulation inner inner covering covering
Instrumentation & Communication Cable
Max. overall dia.
Earthing & Bonding wire
Max. No. of wires
VFD Cable
Conductor Nominal Area
Technical Information
No. of Triads
HV Power Cable
250V RFOU(c), 250V RFCU(c), 250V RFBU(c)
39
Halogen free & Mud resistant Offshore cable
Instrumentation & Communication Cable
Cable Designation (S1, S1/S5) 250V RFOU(i), RFCU(i), RFBU(i)
Application Standard - Design guide
: NEK-606 & IEC 60092-376
- Flame retardant
: IEC 60332-1 &
250V RFOU(i)
IEC 60332-3 Category A
- Halogen content
: IEC 60754-1, 0.5%↓
- Cold bend / impact
: CSA 22.2 No.03 (-40℃/-35℃)
- Mud resistant
: NEK-606 (Mud type only)
- Smoke light transmittance
: IEC 61034, 60%↑
- Sunlight (UV) resistant
: UL 1581
Construction Sectional view
Classification
Code
Conductor Insulation
R
Twisting Individual screen
Construction detail - Stranded tinned annealed copper wires as per IEC 60228, Class 2 - HF EPR as per IEC 60092-351 - Two/Three Insulated cores shall be twisted together to form a pair/Triad
(i)
- CU/PS or AL/PS tape + Tinned copper drain wire - Twisted pairs / triads shall be cabled - Flame retardant & non-hygroscopic fillers may be used
Cabling
- Suitable tape(s) may be applied on the cabled core - A Filler may be applied to obtain a circular Cable
Inner covering Armor Sheath
F
- Flame retardant halogen free thermoset compound
O
- Braid of tinned copper wire (O) / bronze wire (B) /galvanized steel wire (C)
(B,C) U
- A suitable separator tape(s) may be applied under/over the armor - SHF2 or SHF Mud as per IEC 60092-359 - Outer sheath color : Grey (Non-IS Type) or Blue (IS Type) - Each Pair / Triad : Core color
Core identification
① Pair : Black, Light blue
② Triad : Black, Light blue, Brown
- Multi Pairs / Triads : Number printing on the insulation or numbered tape Note. Flexible cable (Class5 Conductor) can be supplied
40
Offshore Cable
Instrumentation & Communication Cable
• •
●
• • •
NEK-606 (2009), IEC 60092-350, 353, 354, 376
mm2
EA
mm
1P 2P 3P 4P 5P 6P 7P 8P 10P 12P 14P 16P 19P 24P 32P 1P 2P 3P 4P 5P 6P 7P 8P 10P 12P 14P 16P 19P 24P 32P 1P 2P 3P 4P 5P 6P 7P 8P 10P 12P 14P 16P 19P 24P 32P 1P 2P 3P 4P 5P 6P 7P 8P 10P 12P 14P 16P 19P 24P 32P
0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5
7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7
1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2
mm
0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7
mm
1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.2 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.2 1.2 1.4
mm
6.8 10.7 11.3 12.4 13.9 14.4 14.4 15.8 18.0 18.8 19.7 21.2 21.7 25.4 28.4 7.2 11.4 12.1 13.2 14.8 15.4 15.4 16.9 19.3 20.1 21.2 22.8 23.3 28.1 30.5 8.2 13.1 13.9 15.3 17.2 17.9 17.9 19.7 22.6 23.5 24.8 26.7 28.1 32.8 35.7 9.0 14.5 15.4 17.0 19.1 19.9 19.9 22.0 25.2 26.2 28.5 30.6 31.3 36.6 40.2
Dia. of wire for armour mm
0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.4 0.4
Thickness Overall diameter of Nominal Tolersheath ance mm
1.1 1.3 1.3 1.3 1.4 1.4 1.4 1.5 1.6 1.6 1.6 1.7 1.7 1.9 2.0 1.1 1.3 1.3 1.4 1.4 1.5 1.5 1.5 1.6 1.7 1.7 1.8 1.8 2.0 2.1 1.2 1.4 1.4 1.5 1.5 1.6 1.6 1.6 1.8 1.8 1.8 1.9 2.0 2.2 2.3 1.2 1.4 1.5 1.5 1.6 1.6 1.6 1.7 1.9 1.9 2.0 2.1 2.1 2.3 2.5
mm
10.5 14.8 15.4 16.5 18.2 18.7 18.7 20.3 22.7 23.5 24.4 26.1 26.6 30.7 33.9 10.9 15.5 16.2 17.5 19.1 19.9 19.9 21.4 24.0 25.0 26.1 27.9 28.4 33.6 36.6 12.1 17.4 18.2 19.8 21.7 22.6 22.6 24.4 27.7 28.6 29.9 32.0 33.6 39.1 42.2 12.9 18.8 19.9 21.5 23.8 24.6 24.6 26.9 30.5 31.5 34.0 36.7 37.4 43.1 47.1
±mm
0.6 0.7 0.8 0.8 0.8 0.9 0.9 0.9 1.0 1.0 1.0 1.1 1.1 1.2 1.3 0.6 0.8 0.8 0.8 0.9 0.9 0.9 0.9 1.0 1.1 1.1 1.1 1.2 1.3 1.4 0.7 0.8 0.8 0.9 1.0 1.0 1.0 1.0 1.1 1.2 1.2 1.3 1.3 1.5 1.6 0.7 0.9 0.9 0.9 1.0 1.0 1.0 1.1 1.2 1.2 1.3 1.4 1.4 1.6 1.7
Conductor Insulation Resistance Resistance (at 20℃) (at 20℃) (Max.) (Min.)
Test Voltage
Cable Weight Approx.
Ω/km
㏁-km
V/5min.
kg/km
26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02
1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 850 850 850 850 850 850 850 850 850 850 850 850 850 850 850
1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500
200 330 380 430 510 550 590 660 790 880 960 1,080 1,190 1,480 1,900 210 360 420 490 570 640 680 760 910 1,020 1,130 1,270 1,410 1,830 2,340 260 440 510 610 710 790 850 940 1,150 1,280 1,430 1,600 1,890 2,430 2,980 300 510 620 740 880 970 1,050 1,190 1,460 1,640 1,940 2,260 2,510 3,110 3,950
Offshore Cable
LV Power & Lighting Cable
No.
Thickness Thickness Nominal of of dia. Insulation inner inner covering covering
Instrumentation & Communication Cable
Max. overall dia.
Earthing & Bonding wire
Max. No. of wires
VFD Cable
Conductor Nominal Area
Technical Information
No. of Pairs
HV Power Cable
250V RFOU(i), 250V RFCU(i), 250V RFBU(i)
41
Halogen free & Mud resistant Offshore cable
Instrumentation & Communication Cable 250V RFOU(i), 250V RFCU(i), 250V RFBU(i) No. of Triads
Conductor Nominal Area
Max. No. of wires
Max. overall dia.
No.
mm2
EA
mm
1T 2T 3T 4T 5T 6T 7T 8T 10T 12T 14T 16T 19T 24T 32T 1T 2T 3T 4T 5T 6T 7T 8T 10T 12T 14T 16T 19T 24T 32T 1T 2T 3T 4T 5T 6T 7T 8T 10T 12T 14T 16T 19T 24T 32T 1T 2T 3T 4T 5T 6T 7T 8T 10T 12T 14T 16T 19T 24T 32T
0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5
42
Offshore Cable
7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7
1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2
Thickness Thickness Nominal of of dia. Insulation inner inner covering covering mm
0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7
mm
1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.2 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.2 1.2 1.2 1.4 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.2 1.2 1.4 1.4 1.6
mm
7.2 11.4 12.2 13.4 14.9 16.9 16.9 18.1 20.5 21.8 22.8 24.2 26.2 30.0 34.4 7.6 12.2 12.9 14.3 15.9 18.0 18.0 19.3 21.9 23.3 24.3 25.9 28.8 32.0 36.8 8.7 14.1 15.0 16.6 18.5 21.0 21.0 22.6 25.8 28.1 29.4 31.3 33.9 37.6 43.7 9.6 15.7 16.7 18.5 20.7 23.5 23.5 25.3 29.7 31.5 32.9 35.1 38.4 42.6 49.6
Dia. of wire for armour mm
0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.4 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.4 0.4 0.4 0.4
Thickness Overall diameter of Nominal Tolersheath ance mm
1.1 1.3 1.3 1.4 1.4 1.5 1.5 1.6 1.7 1.7 1.8 1.8 1.9 2.1 2.2 1.2 1.3 1.4 1.4 1.5 1.6 1.6 1.6 1.7 1.8 1.8 1.9 2.0 2.1 2.3 1.2 1.4 1.5 1.5 1.6 1.7 1.7 1.8 1.9 2.0 2.0 2.1 2.2 2.4 2.6 1.2 1.5 1.5 1.6 1.7 1.8 1.8 1.9 2.0 2.1 2.2 2.3 2.4 2.6 2.9
mm
10.9 15.5 16.3 17.7 19.2 21.4 21.4 22.8 25.4 26.7 27.9 29.3 31.5 35.7 40.7 11.5 16.3 17.2 18.6 20.4 22.7 22.7 24.0 26.8 28.4 29.4 31.2 34.3 38.1 43.3 12.6 18.4 19.5 21.1 23.2 25.9 25.9 27.7 31.1 33.6 34.9 37.4 40.2 44.3 50.8 13.5 20.2 21.2 23.2 25.6 28.6 28.6 30.6 35.2 37.6 39.2 41.6 45.1 49.7 57.3
±mm
0.6 0.8 0.8 0.8 0.9 0.9 0.9 1.0 1.1 1.1 1.1 1.2 1.2 1.4 1.5 0.6 0.8 0.8 0.9 0.9 1.0 1.0 1.0 1.1 1.2 1.2 1.2 1.3 1.4 1.6 0.7 0.9 0.9 0.9 1.0 1.1 1.1 1.1 1.2 1.3 1.3 1.4 1.5 1.6 1.8 0.7 0.9 0.9 1.0 1.1 1.2 1.2 1.2 1.4 1.4 1.5 1.5 1.7 1.8 2.0
Conductor Insulation Resistance Resistance (at 20℃) (at 20℃) (Max.) (Min.)
Test Voltage
Cable Weight Approx.
Ω/km
㏁-km
V/5min.
kg/km
26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02
1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 850 850 850 850 850 850 850 850 850 850 850 850 850 850 850
1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500
220 370 430 510 590 690 740 820 980 1,110 1,230 1,360 1,560 1,990 2,590 240 410 490 580 680 800 860 940 1,130 1,290 1,430 1,600 1,930 2,410 3,060 290 500 610 720 860 1,010 1,080 1,210 1,460 1,760 1,950 2,260 2,590 3,140 4,060 340 610 750 910 1,080 1,270 1,380 1,550 1,970 2,350 2,630 2,940 3,440 4,180 5,480
Instrumentation & Communication Cable
• •
●
• • •
HV Power Cable
NEK-606 (2009), IEC 60092-350, 353, 354, 376
Cable Designation LV Power & Lighting Cable
250V RFOU(i&c), RFCU(i&c), RFBU(i&c)
Application Standard - Design guide
: NEK-606 & IEC 60092-376
- Flame retardant
: IEC 60332-1 & IEC 60332-3 Category A
- Halogen content
: IEC 60754-1, 0.5%↓
- Cold bend / impact
: CSA 22.2 No.03 (-40℃/-35℃)
- Mud resistant
: NEK-606 (Mud type only)
- Smoke light transmittance
: IEC 61034, 60%↑
- Sunlight (UV) resistant
: UL 1581
Instrumentation & Communication Cable
250V RFOU(i&c)
Sectional view
Classification
Code
Conductor Insulation
Construction detail - Stranded tinned annealed copper wires as per IEC 60228, Class 2
R
Twisting Individual screen
Earthing & Bonding wire
Construction
- HF EPR as per IEC 60092-351 - Two/Three Insulated cores shall be twisted together to form a pair/Triad
(i)
- CU/PS or AL/PS tape + Tinned copper drain wire - Twisted pairs / triads shall be cabled - Flame retardant & non-hygroscopic fillers may be used
Cabling
- Suitable tape(s) may be applied on the cabled core
Collective screen
(c)
- CU/PS or AL/PS tape + Tinned copper drain wire
Inner covering
F
- Flame retardant halogen free thermoset compound
O
- Braid of tinned copper wire (O) / bronze wire (B) /galvanized steel wire (C)
Armor Sheath
(B,C) U
VFD Cable
- A Filler may be applied to obtain a circular Cable
- A suitable separator tape(s) may be applied under/over the armor - SHF2 or SHF Mud as per IEC 60092-359 - Outer sheath color : Grey (Non-IS Type) or Blue (IS Type) - Each Pair / Triad : Core color ① Pair : Black, Light blue
② Triad : Black, Light blue, Brown
Technical Information
Core identification
- Multi Pairs / Triads : Number printing on the insulation or numbered tape Note. Flexible cable (Class5 Conductor) can be supplied
Offshore Cable
43
Halogen free & Mud resistant Offshore cable
Instrumentation & Communication Cable 250V RFOU(i&c), 250V RFCU(i&c), 250V RFBU(i&c) No. of Pairs
Conductor Nominal Area
Max. No. of wires
Max. overall dia.
No.
mm2
EA
mm
2P 3P 4P 5P 6P 7P 8P 10P 12P 14P 16P 19P 24P 32P 2P 3P 4P 5P 6P 7P 8P 10P 12P 14P 16P 19P 24P 32P 2P 3P 4P 5P 6P 7P 8P 10P 12P 14P 16P 19P 24P 32P 2P 3P 4P 5P 6P 7P 8P 10P 12P 14P 16P 19P 24P 32P
0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5
44
Offshore Cable
7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7
1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2
Thickness Thickness Nominal of of dia. Insulation inner inner covering covering mm
0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7
mm
1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.2 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.2 1.2 1.4
mm
10.8 11.4 12.5 14.0 14.5 14.5 15.9 18.1 18.9 19.8 21.3 21.8 25.5 28.5 11.5 12.2 13.3 14.9 15.5 15.5 17.0 19.4 20.2 21.3 22.9 23.4 28.2 30.6 13.2 14.0 15.4 17.3 18.0 18.0 19.8 22.7 23.6 24.9 26.8 28.2 32.9 35.8 14.6 15.5 17.1 19.2 20.0 20.0 22.1 25.3 26.3 28.6 30.7 31.4 36.7 40.3
Dia. of wire for armour mm
0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.4 0.4
Thickness Overall diameter of Nominal Tolersheath ance mm
1.3 1.3 1.4 1.4 1.4 1.4 1.5 1.6 1.6 1.6 1.7 1.7 1.9 2.0 1.3 1.3 1.4 1.4 1.5 1.5 1.5 1.6 1.7 1.7 1.8 1.8 2.0 2.1 1.4 1.4 1.5 1.5 1.6 1.6 1.6 1.8 1.8 1.8 1.9 2.0 2.2 2.3 1.4 1.5 1.5 1.6 1.7 1.7 1.7 1.9 1.9 2.0 2.1 2.1 2.3 2.5
mm
14.9 15.5 16.8 18.3 18.8 18.8 20.4 22.8 23.6 24.5 26.2 26.7 30.8 34.0 15.6 16.3 17.6 19.2 20.0 20.0 21.5 24.1 25.1 26.2 28.0 28.5 33.7 36.7 17.5 18.3 19.9 21.8 22.7 22.7 24.5 27.8 28.7 30.0 32.1 33.7 39.2 42.3 18.9 20.0 21.6 23.9 24.9 24.9 27.0 30.6 31.6 34.1 36.8 37.5 43.2 47.2
±mm
0.7 0.8 0.8 0.8 0.9 0.9 0.9 1.0 1.0 1.0 1.1 1.1 1.2 1.3 0.8 0.8 0.8 0.9 0.9 0.9 0.9 1.0 1.1 1.1 1.1 1.2 1.3 1.4 0.8 0.8 0.9 1.0 1.0 1.0 1.0 1.1 1.2 1.2 1.3 1.3 1.5 1.6 0.9 0.9 0.9 1.0 1.0 1.0 1.1 1.2 1.2 1.3 1.4 1.4 1.6 1.7
Conductor Insulation Resistance Resistance (at 20℃) (at 20℃) (Max.) (Min.)
Test Voltage
Cable Weight Approx.
Ω/km
㏁-km
V/5min.
kg/km
26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02
1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 850 850 850 850 850 850 850 850 850 850 850 850 850 850
1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500
340 390 460 530 570 600 680 810 900 990 1,100 1,210 1,500 1,930 380 440 510 590 660 700 780 930 1,050 1,160 1,300 1,430 1,870 2,370 450 530 630 730 810 870 970 1,180 1,310 1,460 1,630 1,920 2,460 3,020 540 640 760 900 1,010 1,090 1,220 1,490 1,670 1,970 2,290 2,550 3,150 3,990
Instrumentation & Communication Cable
• •
●
• • •
NEK-606 (2009), IEC 60092-350, 353, 354, 376
mm2
EA
mm
2T 3T 4T 5T 6T 7T 8T 10T 12T 14T 16T 19T 24T 32T 2T 3T 4T 5T 6T 7T 8T 10T 12T 14T 16T 19T 24T 32T 2T 3T 4T 5T 6T 7T 8T 10T 12T 14T 16T 19T 24T 32T 2T 3T 4T 5T 6T 7T 8T 10T 12T 14T 16T 19T 24T 32T
0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5
7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7
1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2
mm
0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7
mm
1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.2 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.2 1.2 1.2 1.4 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.2 1.2 1.4 1.4 1.6
mm
11.5 12.3 13.5 15.0 17.0 17.0 18.2 20.6 21.9 22.9 24.3 26.3 30.1 34.5 12.3 13.0 14.4 16.0 18.1 18.1 19.4 22.0 23.4 24.4 26.0 28.9 32.1 36.9 14.2 15.1 16.7 18.6 21.1 21.1 22.7 25.9 28.2 29.5 31.4 34.0 37.7 43.8 15.8 16.8 18.6 20.8 23.6 23.6 25.4 29.8 31.6 33.0 35.2 38.5 42.7 49.7
Dia. of wire for armour mm
0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.4 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.4 0.4 0.4 0.4
Thickness Overall diameter of Nominal Tolersheath ance mm
1.3 1.3 1.4 1.5 1.5 1.5 1.6 1.7 1.7 1.8 1.8 1.9 2.1 2.2 1.3 1.4 1.4 1.5 1.6 1.6 1.6 1.7 1.8 1.8 1.9 2.0 2.2 2.3 1.4 1.5 1.5 1.6 1.7 1.7 1.8 1.9 2.0 2.0 2.1 2.2 2.4 2.6 1.5 1.5 1.6 1.7 1.8 1.8 1.9 2.0 2.1 2.2 2.3 2.4 2.6 2.9
mm
15.6 16.4 17.8 19.5 21.5 21.5 22.9 25.5 26.8 28.0 29.4 31.6 36.2 40.8 16.4 17.3 18.7 20.5 22.8 22.8 24.1 26.9 28.5 29.5 31.3 34.4 38.4 43.4 18.5 19.6 21.2 23.3 26.0 26.0 27.8 31.2 33.7 35.0 37.5 40.3 44.4 50.9 20.3 21.3 23.3 25.7 28.7 28.7 30.7 35.3 37.7 39.3 41.7 45.2 49.8 57.4
Conductor Insulation Resistance Resistance (at 20℃) (at 20℃) (Max.) (Min.)
Test Voltage
Cable Weight Approx.
±mm
Ω/km
㏁-km
V/5min.
kg/km
0.8 0.8 0.8 0.9 0.9 0.9 1.0 1.1 1.1 1.1 1.2 1.2 1.4 1.5 0.8 0.8 0.9 0.9 1.0 1.0 1.0 1.1 1.2 1.2 1.2 1.3 1.5 1.6 0.9 0.9 0.9 1.0 1.1 1.1 1.1 1.2 1.3 1.4 1.4 1.5 1.6 1.8 0.9 0.9 1.0 1.1 1.2 1.2 1.2 1.4 1.4 1.5 1.6 1.7 1.8 2.0
26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02
1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 850 850 850 850 850 850 850 850 850 850 850 850 850 850
1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500
380 450 530 620 710 760 840 1,010 1,130 1,260 1,390 1,590 2,100 2,630 430 510 600 700 820 880 970 1,160 1,320 1,460 1,630 1,960 2,470 3,100 520 630 740 880 1,030 1,110 1,240 1,490 1,790 1,980 2,300 2,630 3,180 4,110 640 770 930 1,110 1,300 1,410 1,580 2,010 2,380 2,670 2,980 3,490 4,230 5,530
Offshore Cable
LV Power & Lighting Cable
No.
Thickness Thickness Nominal of of dia. Insulation inner inner covering covering
Instrumentation & Communication Cable
Max. overall dia.
Earthing & Bonding wire
Max. No. of wires
VFD Cable
Conductor Nominal Area
Technical Information
No. of Triads
HV Power Cable
250V RFOU(i&c), 250V RFCU(i&c), 250V RFBU(i&c)
45
Halogen free & Mud resistant Offshore cable
Instrumentation & Communication Cable
Cable Designation (S14) 250V BU(c)
Application Standard - Design guide
: NEK-606 & IEC 60092-376
- Flame retardant
: IEC 60332-1 &
IEC 60332-3 Category A
250V BU(c)
- Fire resistance
: IEC 60331-21(90min)
IEC 60331-1,-2(120min)
- Halogen content
: IEC 60754-1, 0.5%↓
- Cold bend / impact
: CSA 22.2 No.03 (-40℃/-35℃)
- Mud resistant
: NEK-606 (Mud type only)
- Smoke light transmittance
: IEC 61034, 60%↑
- Sunlight (UV) resistant
: UL 1581
Construction Sectional view
Classification
Code
Conductor Fire resisting layer Insulation
Construction detail - Stranded tinned annealed copper wires as per IEC 60228, Class 2
B
Twisting
- Mica/glass tape - HF EPR as per IEC 60092-351 - Two/Three Insulated cores shall be twisted together to form a pair/Triad - Twisted pairs / triads shall be cabled - Flame retardant & non-hygroscopic fillers may be used
Cabling
- Suitable tape(s) may be applied on the cabled core - A Filler may be applied to obtain a circular Cable
Collective screen
(c)
Sheath
U
- CU/PS or AL/PS tape + Tinned copper drain wire - SHF2 or SHF Mud as per IEC 60092-359 - Outer sheath color : Grey (Non-IS Type) or Blue (IS Type) - Each Pair / Triad : Core color
Core identification
① Pair : Black, Light blue
② Triad : Black, Light blue, Brown
- Multi Pairs / Triads : Number printing on the insulation or numbered tape Note. Flexible cable (Class5 Conductor) can be supplied
46
Offshore Cable
Instrumentation & Communication Cable
• •
●
• • •
NEK-606 (2009), IEC 60092-350, 353, 354, 376
EA
mm
0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5
7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7
1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2
Thickness of sheath
mm
mm
0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7
1.0 1.2 1.2 1.2 1.3 1.3 1.3 1.4 1.5 1.5 1.5 1.6 1.6 1.7 1.9 1.0 1.2 1.2 1.3 1.3 1.4 1.4 1.4 1.5 1.5 1.6 1.6 1.7 1.8 2.0 1.1 1.3 1.3 1.3 1.4 1.5 1.5 1.5 1.6 1.7 1.7 1.8 1.8 2.0 2.2 1.1 1.3 1.4 1.4 1.5 1.5 1.5 1.6 1.7 1.8 1.8 1.9 2.0 2.1 2.3
Overall diameter Nominal
Tolerance
mm
±mm
7.6 11.6 12.4 13.2 15.0 16.0 16.0 17.2 19.5 20.3 21.1 22.8 23.9 27.2 31.4 8.0 12.3 13.2 14.2 15.9 17.2 17.2 18.3 20.8 21.6 22.6 24.3 25.6 29.4 33.7 9.2 14.2 15.2 16.2 18.4 19.9 19.9 21.2 24.1 25.3 26.2 28.4 29.9 34.3 39.3 10.0 15.6 16.9 18.0 20.4 21.9 21.9 23.6 26.7 28.1 29.4 31.8 33.5 38.1 43.7
0.5 0.6 0.7 0.7 0.8 0.8 0.8 0.8 0.9 0.9 0.9 1.0 1.0 1.1 1.2 0.5 0.7 0.7 0.7 0.8 0.8 0.8 0.8 0.9 0.9 1.0 1.0 1.1 1.2 1.3 0.6 0.7 0.8 0.8 0.9 0.9 0.9 0.9 1.0 1.1 1.1 1.2 1.2 1.3 1.5 0.6 0.8 0.8 0.8 0.9 1.0 1.0 1.0 1.1 1.1 1.2 1.3 1.3 1.4 1.6
Conductor Resistance (at 20℃) (Max.)
Insulation Resistance (at 20℃) (Min.)
Test Voltage
Cable Weight Approx.
Ω/km
㏁-km
V/5min.
kg/km
26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02
1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 850 850 850 850 850 850 850 850 850 850 850 850 850 850 850
1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500
90 170 200 240 290 330 360 410 500 570 630 720 820 1,020 1,360 100 190 230 280 340 390 430 470 580 660 760 850 980 1,240 1,620 130 240 300 360 440 520 560 630 770 900 1,010 1,150 1,330 1,680 2,190 160 300 390 470 580 660 730 830 1,030 1,200 1,370 1,560 1,810 2,250 2,940
Offshore Cable
LV Power & Lighting Cable
mm2
Thickness of Insulation
Instrumentation & Communication Cable
Max. overall dia.
Earthing & Bonding wire
1P 2P 3P 4P 5P 6P 7P 8P 10P 12P 14P 16P 19P 24P 32P 1P 2P 3P 4P 5P 6P 7P 8P 10P 12P 14P 16P 19P 24P 32P 1P 2P 3P 4P 5P 6P 7P 8P 10P 12P 14P 16P 19P 24P 32P 1P 2P 3P 4P 5P 6P 7P 8P 10P 12P 14P 16P 19P 24P 32P
Max. No. of wires
VFD Cable
No.
Conductor Nominal Area
Technical Information
No. of Pairs
HV Power Cable
250V BU(c)
47
Halogen free & Mud resistant Offshore cable
Instrumentation & Communication Cable 250V BU(c) No. of Triads
No.
1T 2T 3T 4T 5T 6T 7T 8T 10T 12T 14T 16T 19T 24T 32T 1T 2T 3T 4T 5T 6T 7T 8T 10T 12T 14T 16T 19T 24T 32T 1T 2T 3T 4T 5T 6T 7T 8T 10T 12T 14T 16T 19T 24T 32T 1T 2T 3T 4T 5T 6T 7T 8T 10T 12T 14T 16T 19T 24T 32T
48
Conductor Nominal Area
Max. No. of wires
mm2
EA
0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5
Offshore Cable
Max. overall dia. mm
7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7
1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2
Thickness of Insulation
Thickness of sheath
mm
mm
0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7
1.0 1.2 1.2 1.3 1.3 1.4 1.4 1.5 1.6 1.6 1.7 1.7 1.8 2.0 2.1 1.1 1.2 1.3 1.3 1.4 1.5 1.5 1.5 1.7 1.7 1.8 1.8 1.9 2.1 2.3 1.1 1.4 1.4 1.5 1.6 1.7 1.7 1.7 1.9 1.9 2.0 2.1 2.2 2.3 2.6 1.1 1.4 1.4 1.5 1.6 1.7 1.7 1.8 1.9 2.0 2.1 2.1 2.3 2.4 2.7
Overall diameter Nominal
Tolerance
mm
±mm
8.0 12.7 13.5 15.0 16.5 18.8 18.8 20.3 23.1 24.4 25.6 27.2 29.7 33.2 38.1 8.7 13.6 14.6 16.0 17.9 20.4 20.4 21.8 25.0 26.4 27.8 29.7 32.2 35.9 41.4 9.8 17.1 18.1 20.0 22.2 25.0 25.0 26.7 30.7 32.3 33.9 36.5 39.4 43.6 50.2 10.6 17.3 18.4 20.5 22.9 26.1 26.1 28.1 32.2 34.3 36.0 38.2 41.6 46.2 53.5
0.5 0.7 0.7 0.8 0.8 0.9 0.9 0.9 1.0 1.0 1.1 1.1 1.2 1.3 1.4 0.6 0.7 0.7 0.8 0.8 0.9 0.9 1.0 1.1 1.1 1.1 1.2 1.3 1.4 1.5 0.6 0.8 0.8 0.9 1.0 1.1 1.1 1.1 1.2 1.3 1.3 1.4 1.5 1.6 1.8 0.6 0.8 0.9 0.9 1.0 1.1 1.1 1.1 1.3 1.3 1.4 1.4 1.5 1.7 1.9
Conductor Resistance (at 20℃) (Max.)
Insulation Resistance (at 20℃) (Min.)
Test Voltage
Cable Weight Approx.
Ω/km
㏁-km
V/5min.
kg/km
26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02
1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 850 850 850 850 850 850 850 850 850 850 850 850 850 850 850
1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500
110 200 250 320 380 460 500 570 700 800 920 1,020 1,220 1,520 1,960 130 230 300 370 450 540 600 660 830 960 1,090 1,240 1,450 1,810 2,360 160 330 410 520 630 750 820 920 1,170 1,330 1,520 1,730 2,020 2,480 3,260 200 390 510 650 790 950 1,050 1,200 1,500 1,750 2,010 2,250 2,660 3,290 4,340
Instrumentation & Communication Cable
• •
●
• • •
HV Power Cable
NEK-606 (2009), IEC 60092-350, 353, 354, 376
Cable Designation (S13) LV Power & Lighting Cable
250V BU(i)
Application Standard - Design guide
: NEK-606 & IEC 60092-376
- Flame retardant
: IEC 60332-1 &
IEC 60332-3 Category A : IEC 60331-21(90min)
IEC 60331-1,-2(120min)
- Halogen content
: IEC 60754-1, 0.5%↓
- Cold bend / impact
: CSA 22.2 No.03 (-40℃/-35℃)
- Mud resistant
: NEK-606 (Mud type only)
- Smoke light transmittance
: IEC 61034, 60%↑
- Sunlight (UV) resistant
: UL 1581
Instrumentation & Communication Cable
250V BU(i)
- Fire resistance
Sectional view
Classification
Code
Conductor Fire resisting layer Insulation
Construction detail - Stranded tinned annealed copper wires as per IEC 60228, Class 2
B
Twisting Individual screen
Earthing & Bonding wire
Construction
- Mica/glass tape - HF EPR as per IEC 60092-351 - Two/Three Insulated cores shall be twisted together to form a pair/Triad
(i)
- CU/PS or AL/PS tape + Tinned copper drain wire - Twisted pairs / triads shall be cabled - Flame retardant & non-hygroscopic fillers may be used
Cabling
- Suitable tape(s) may be applied on the cabled core
Sheath
U
VFD Cable
- A Filler may be applied to obtain a circular Cable - SHF2 or SHF Mud as per IEC 60092-359 - Outer sheath color : Grey (Non-IS Type) or Blue (IS Type) - Each Pair / Triad : Core color Core identification
① Pair : Black, Light blue
② Triad : Black, Light blue, Brown
- Multi Pairs / Triads : Number printing on the insulation or numbered tape
Technical Information
Note. Flexible cable (Class5 Conductor) can be supplied
Offshore Cable
49
Halogen free & Mud resistant Offshore cable
Instrumentation & Communication Cable 250V BU(i) No. of Pairs
No.
1P 2P 3P 4P 5P 6P 7P 8P 10P 12P 14P 16P 19P 24P 32P 1P 2P 3P 4P 5P 6P 7P 8P 10P 12P 14P 16P 19P 24P 32P 1P 2P 3P 4P 5P 6P 7P 8P 10P 12P 14P 16P 19P 24P 32P 1P 2P 3P 4P 5P 6P 7P 8P 10P 12P 14P 16P 19P 24P 32P
50
Conductor Nominal Area
Max. No. of wires
Max. overall dia.
mm2
EA
mm
0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5
Offshore Cable
7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7
1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2
Thickness of Insulation
Thickness of sheath
mm
mm
0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7
1.0 1.2 1.2 1.3 1.3 1.4 1.4 1.4 1.5 1.6 1.6 1.7 1.7 1.8 1.9 1.0 1.2 1.2 1.3 1.4 1.4 1.4 1.5 1.6 1.6 1.7 1.7 1.7 1.9 2.0 1.1 1.3 1.3 1.4 1.5 1.5 1.5 1.6 1.7 1.7 1.8 1.9 1.9 2.1 2.2 1.1 1.3 1.4 1.5 1.5 1.6 1.6 1.7 1.8 1.9 1.9 2.0 2.0 2.3 2.4
Overall diameter Nominal
Tolerance
mm
±mm
7.6 12.3 13.0 14.5 16.1 16.9 16.9 18.5 21.2 22.2 23.3 25.2 25.7 30.2 32.9 8.0 13.0 13.8 15.3 17.3 17.9 17.9 19.8 22.7 23.6 24.9 26.7 27.3 32.3 35.2 9.2 15.0 15.9 17.6 19.9 20.6 20.6 22.8 26.1 27.2 28.7 31.2 31.9 37.5 40.8 10.0 16.4 17.6 19.5 21.8 22.8 22.8 25.3 29.1 30.5 32.0 34.5 35.3 41.7 45.3
0.5 0.7 0.7 0.7 0.8 0.8 0.8 0.9 0.9 1.0 1.0 1.1 1.1 1.2 1.3 0.5 0.7 0.7 0.8 0.8 0.8 0.8 0.9 1.0 1.0 1.0 1.1 1.1 1.3 1.4 0.6 0.8 0.8 0.8 0.9 0.9 0.9 1.0 1.1 1.1 1.2 1.2 1.3 1.4 1.5 0.6 0.8 0.8 0.9 1.0 1.0 1.0 1.1 1.2 1.2 1.3 1.3 1.4 1.6 1.7
Conductor Resistance (at 20℃) (Max.)
Insulation Resistance (at 20℃) (Min.)
Test Voltage
Cable Weight Approx.
Ω/km
㏁-km
V/5min.
kg/km
26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02
1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 850 850 850 850 850 850 850 850 850 850 850 850 850 850 850
1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500
90 180 230 290 340 400 430 490 610 710 800 910 1,030 1,320 1,680 100 200 260 330 410 460 510 590 730 830 960 1,070 1,230 1,580 2,030 130 260 330 420 520 590 650 750 930 1,070 1,230 1,420 1,620 2,060 2,630 160 320 430 540 660 770 850 980 1,230 1,440 1,640 1,860 2,130 2,740 3,510
Instrumentation & Communication Cable
• •
●
• • •
NEK-606 (2009), IEC 60092-350, 353, 354, 376
EA
mm
0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5
7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7
1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2
Thickness of sheath
mm
mm
0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7
1.0 1.2 1.3 1.3 1.4 1.5 1.5 1.5 1.6 1.7 1.7 1.8 1.9 2.0 2.2 1.1 1.3 1.3 1.4 1.4 1.5 1.5 1.6 1.7 1.8 1.8 1.9 2.0 2.1 2.3 1.1 1.3 1.4 1.4 1.5 1.6 1.6 1.7 1.8 1.9 2.0 2.1 2.2 2.3 2.6 1.1 1.4 1.4 1.5 1.6 1.7 1.7 1.8 2.0 2.0 2.1 2.2 2.3 2.5 2.8
Overall diameter Nominal
Tolerance
mm
±mm
8.0 13.1 14.1 15.5 17.3 19.7 19.7 21.1 24.0 25.6 26.7 28.6 31.2 34.6 40.0 8.7 14.2 15.1 16.8 18.5 21.1 21.1 22.8 26.0 27.7 29.0 31.0 33.6 37.4 43.1 9.8 16.1 17.4 19.1 21.4 24.4 24.4 26.3 30.2 32.1 33.7 36.0 39.0 43.4 50.2 10.6 17.7 18.9 21.0 23.5 26.8 26.8 29.1 33.4 35.3 37.1 39.6 42.9 47.9 55.4
0.5 0.7 0.7 0.8 0.8 0.9 0.9 0.9 1.0 1.1 1.1 1.2 1.2 1.3 1.5 0.6 0.7 0.8 0.8 0.9 0.9 0.9 1.0 1.1 1.1 1.2 1.2 1.3 1.4 1.6 0.6 0.8 0.8 0.9 0.9 1.0 1.0 1.1 1.2 1.3 1.3 1.4 1.5 1.6 1.8 0.6 0.8 0.9 0.9 1.0 1.1 1.1 1.2 1.3 1.4 1.4 1.5 1.6 1.7 2.0
Conductor Resistance (at 20℃) (Max.)
Insulation Resistance (at 20℃) (Min.)
Test Voltage
Cable Weight Approx.
Ω/km
㏁-km
V/5min.
kg/km
26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02
1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 850 850 850 850 850 850 850 850 850 850 850 850 850 850 850
1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500
110 220 290 350 430 520 580 640 800 940 1,060 1,200 1,430 1,770 2,320 130 260 330 420 510 610 680 770 960 1,130 1,290 1,470 1,720 2,130 2,790 160 320 430 530 660 790 880 1,000 1,260 1,480 1,700 1,930 2,260 2,790 3,700 200 410 550 700 860 1,040 1,160 1,340 1,680 1,950 2,240 2,550 2,990 3,740 4,940
Offshore Cable
LV Power & Lighting Cable
mm2
Thickness of Insulation
Instrumentation & Communication Cable
Max. overall dia.
Earthing & Bonding wire
1T 2T 3T 4T 5T 6T 7T 8T 10T 12T 14T 16T 19T 24T 32T 1T 2T 3T 4T 5T 6T 7T 8T 10T 12T 14T 16T 19T 24T 32T 1T 2T 3T 4T 5T 6T 7T 8T 10T 12T 14T 16T 19T 24T 32T 1T 2T 3T 4T 5T 6T 7T 8T 10T 12T 14T 16T 19T 24T 32T
Max. No. of wires
VFD Cable
No.
Conductor Nominal Area
Technical Information
No. of Triads
HV Power Cable
250V BU(i)
51
Halogen free & Mud resistant Offshore cable
Instrumentation & Communication Cable
Cable Designation 250V BU(i&c)
Application Standard - Design guide
: NEK-606 & IEC 60092-376
- Flame retardant
: IEC 60332-1 &
IEC 60332-3 Category A
250V BU(i&c)
- Fire resistance
: IEC 60331-21(90min)
IEC 60331-1,-2(120min)
- Halogen content
: IEC 60754-1, 0.5%↓
- Cold bend / impact
: CSA 22.2 No.03 (-40℃/-35℃)
- Mud resistant
: NEK-606 (Mud type only)
- Smoke light transmittance
: IEC 61034, 60%↑
- Sunlight (UV) resistant
: UL 1581
Construction Sectional view
Classification
Code
Conductor Fire resisting layer Insulation
B
Twisting Individual screen
Construction detail - Stranded tinned annealed copper wires as per IEC 60228, Class 2 - Mica/glass tape - HF EPR as per IEC 60092-351 - Two/Three Insulated cores shall be twisted together to form a pair/Triad
(i)
- CU/PS or AL/PS tape + Tinned copper drain wire - Twisted pairs / triads shall be cabled - Flame retardant & non-hygroscopic fillers may be used
Cabling
- Suitable tape(s) may be applied on the cabled core - A Filler may be applied to obtain a circular Cable
Collective screen
(c)
Sheath
U
- CU/PS or AL/PS tape + Tinned copper drain wire - SHF2 or SHF Mud as per IEC 60092-359 - Outer sheath color : Grey (Non-IS Type) or Blue (IS Type) - Each Pair / Triad : Core color
Core identification
① Pair : Black, Light blue
② Triad : Black, Light blue, Brown
- Multi Pairs / Triads : Number printing on the insulation or numbered tape Note. Flexible cable (Class5 Conductor) can be supplied
52
Offshore Cable
Instrumentation & Communication Cable
• •
●
• • •
NEK-606 (2009), IEC 60092-350, 353, 354, 376
EA
mm
0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5
7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7
1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2
Thickness of sheath
mm
mm
0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7
1.2 1.2 1.3 1.3 1.4 1.4 1.4 1.5 1.6 1.6 1.7 1.7 1.9 2.0 1.2 1.3 1.3 1.4 1.4 1.4 1.5 1.6 1.6 1.7 1.7 1.8 1.9 2.0 1.3 1.3 1.4 1.5 1.5 1.5 1.6 1.7 1.7 1.8 1.9 1.9 2.1 2.2 1.3 1.4 1.5 1.5 1.6 1.6 1.7 1.8 1.9 1.9 2.0 2.0 2.3 2.4
Overall diameter Nominal
Tolerance
mm
±mm
12.4 13.1 14.6 16.2 17.0 17.0 18.6 21.3 22.3 23.4 25.3 25.8 30.5 33.2 13.1 14.1 15.4 17.4 18.0 18.0 19.9 22.8 23.7 25.0 26.8 27.6 32.4 35.3 15.1 16.0 17.7 20.0 20.7 20.7 22.9 26.2 27.3 29.0 31.3 32.0 37.6 40.9 16.5 17.7 19.6 21.9 22.9 22.9 25.4 29.2 30.6 32.1 34.6 35.4 41.8 45.4
0.7 0.7 0.7 0.8 0.8 0.8 0.9 0.9 1.0 1.0 1.1 1.1 1.2 1.3 0.7 0.7 0.8 0.8 0.8 0.8 0.9 1.0 1.0 1.1 1.1 1.1 1.3 1.4 0.8 0.8 0.8 0.9 0.9 0.9 1.0 1.1 1.1 1.2 1.2 1.3 1.4 1.5 0.8 0.8 0.9 1.0 1.0 1.0 1.1 1.2 1.2 1.3 1.3 1.4 1.6 1.7
Conductor Resistance (at 20℃) (Max.)
Insulation Resistance (at 20℃) (Min.)
Test Voltage
Cable Weight Approx.
Ω/km
㏁-km
V/5min.
kg/km
26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02
1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 850 850 850 850 850 850 850 850 850 850 850 850 850 850
1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500
190 240 300 360 410 450 510 630 730 820 940 1,060 1,370 1,740 220 290 350 430 480 530 610 750 860 980 1,100 1,270 1,620 2,060 280 350 440 540 610 670 770 960 1,100 1,280 1,450 1,650 2,090 2,670 340 450 570 680 790 880 1,010 1,270 1,480 1,670 1,900 2,170 2,780 3,560
Offshore Cable
LV Power & Lighting Cable
mm2
Thickness of Insulation
Instrumentation & Communication Cable
Max. overall dia.
Earthing & Bonding wire
2P 3P 4P 5P 6P 7P 8P 10P 12P 14P 16P 19P 24P 32P 2P 3P 4P 5P 6P 7P 8P 10P 12P 14P 16P 19P 24P 32P 2P 3P 4P 5P 6P 7P 8P 10P 12P 14P 16P 19P 24P 32P 2P 3P 4P 5P 6P 7P 8P 10P 12P 14P 16P 19P 24P 32P
Max. No. of wires
VFD Cable
No.
Conductor Nominal Area
Technical Information
No. of Pairs
HV Power Cable
250V BU(i&c)
53
Halogen free & Mud resistant Offshore cable
Instrumentation & Communication Cable 250V BU(i&c) No. of Triads
No.
2T 3T 4T 5T 6T 7T 8T 10T 12T 14T 16T 19T 24T 32T 2T 3T 4T 5T 6T 7T 8T 10T 12T 14T 16T 19T 24T 32T 2T 3T 4T 5T 6T 7T 8T 10T 12T 14T 16T 19T 24T 32T 2T 3T 4T 5T 6T 7T 8T 10T 12T 14T 16T 19T 24T 32T
54
Conductor Nominal Area
Max. No. of wires
mm2
EA
0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5
Offshore Cable
Max. overall dia. mm
7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7
1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2
Thickness of Insulation
Thickness of sheath
mm
mm
0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7
1.2 1.3 1.3 1.4 1.5 1.5 1.5 1.6 1.7 1.7 1.8 1.9 2.0 2.2 1.3 1.3 1.4 1.4 1.5 1.5 1.6 1.7 1.8 1.8 1.9 2.0 2.1 2.3 1.3 1.4 1.4 1.5 1.6 1.6 1.7 1.9 1.9 2.0 2.1 2.2 2.3 2.6 1.4 1.4 1.5 1.6 1.7 1.7 1.8 2.0 2.0 2.1 2.2 2.3 2.5 2.8
Overall diameter Nominal
Tolerance
mm
±mm
13.2 14.2 15.6 17.4 19.8 19.8 21.2 24.1 25.7 26.8 28.7 31.3 34.7 40.1 14.3 15.2 16.9 18.6 21.2 21.2 22.9 26.1 27.8 29.1 31.1 33.7 37.5 43.2 16.2 17.5 19.2 21.5 24.5 24.5 26.4 30.5 32.2 33.8 36.1 39.1 43.5 50.3 17.8 19.0 21.1 23.6 26.9 26.9 29.2 33.5 35.4 37.2 39.7 43.0 48.0 55.5
0.7 0.7 0.8 0.8 0.9 0.9 0.9 1.0 1.1 1.1 1.2 1.2 1.3 1.5 0.7 0.8 0.8 0.9 0.9 0.9 1.0 1.1 1.1 1.2 1.2 1.3 1.4 1.6 0.8 0.8 0.9 0.9 1.0 1.0 1.1 1.2 1.3 1.3 1.4 1.5 1.6 1.8 0.8 0.9 0.9 1.0 1.1 1.1 1.2 1.3 1.4 1.4 1.5 1.6 1.7 2.0
Conductor Resistance (at 20℃) (Max.)
Insulation Resistance (at 20℃) (Min.)
Test Voltage
Cable Weight Approx.
Ω/km
㏁-km
V/5min.
kg/km
26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02
1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 850 850 850 850 850 850 850 850 850 850 850 850 850 850
1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500
310 380 460 550 650 700 780 950 1,100 1,220 1,380 1,610 2,050 2,630 280 350 440 530 640 700 800 990 1,160 1,320 1,500 1,760 2,160 2,830 340 450 560 680 820 910 1,030 1,310 1,510 1,730 1,960 2,300 2,830 3,740 440 570 730 890 1,070 1,190 1,370 1,720 1,990 2,280 2,590 3,030 3,780 4,990
Instrumentation & Communication Cable
• •
●
• • •
HV Power Cable
NEK-606 (2009), IEC 60092-350, 353, 354, 376
Cable Designation (S4, S4/S8) LV Power & Lighting Cable
250V BFOU(c), BFCU(c), BFBU(c)
Application Standard - Design guide
: NEK-606 & IEC 60092-376
- Flame retardant
: IEC 60332-1 &
IEC 60332-3 Category A
- Fire resistance
: IEC 60331-21(90min) IEC 60331-1,-2(120min)
- Halogen content
: IEC 60754-1, 0.5%↓
- Cold bend / impact
: CSA 22.2 No.03 (-40℃/-35℃)
- Mud resistant
: NEK-606 (Mud type only)
- Smoke light transmittance
: IEC 61034, 60%↑
- Sunlight (UV) resistant
: UL 1581
Instrumentation & Communication Cable
250V BFOU(c)
Sectional view
Classification
Code
Conductor Fire resisting layer Insulation
Earthing & Bonding wire
Construction Construction detail - Stranded tinned annealed copper wires as per IEC 60228, Class 2 B
Twisting
- Mica/glass tape - HF EPR as per IEC 60092-351 - Two/Three Insulated cores shall be twisted together to form a pair/Triad - Twisted pairs / triads shall be cabled - Flame retardant & non-hygroscopic fillers may be used
Cabling
- Suitable tape(s) may be applied on the cabled core
Collective screen
(c)
- CU/PS or AL/PS tape + Tinned copper drain wire
Inner covering
F
- Flame retardant halogen free thermoset compound
O
- Braid of tinned copper wire (O) / bronze wire (B) /galvanized steel wire (C)
Armor Sheath
(B,C) U
VFD Cable
- A Filler may be applied to obtain a circular Cable
- A suitable separator tape(s) may be applied under/over the armor - SHF2 or SHF Mud as per IEC 60092-359 - Outer sheath color : Grey (Non-IS Type) or Blue (IS Type) - Each Pair / Triad : Core color ① Pair : Black, Light blue
② Triad : Black, Light blue, Brown
Technical Information
Core identification
- Multi Pairs / Triads : Number printing on the insulation or numbered tape Note. Flexible cable (Class5 Conductor) can be supplied
Offshore Cable
55
Halogen free & Mud resistant Offshore cable
Instrumentation & Communication Cable 250V BFOU(c), 250V BFCU(c), 250V BFBU(c) No. of Pairs
Conductor Nominal Area
Max. No. of wires
Max. overall dia.
No.
mm2
EA
mm
1P 2P 3P 4P 5P 6P 7P 8P 10P 12P 14P 16P 19P 24P 32P 1P 2P 3P 4P 5P 6P 7P 8P 10P 12P 14P 16P 19P 24P 32P 1P 2P 3P 4P 5P 6P 7P 8P 10P 12P 14P 16P 19P 24P 32P 1P 2P 3P 4P 5P 6P 7P 8P 10P 12P 14P 16P 19P 24P 32P
0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5
56
Offshore Cable
7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7
1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2
Thickness Thickness Nominal of of dia. Insulation inner inner covering covering mm
0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7
mm
1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.2 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.2 1.2 1.4
mm
7.4 11.0 11.8 12.6 14.2 15.2 15.2 16.2 18.3 19.1 19.9 21.4 22.5 25.6 30.0 7.8 11.7 12.6 13.4 15.1 16.2 16.2 17.3 19.6 20.4 21.2 22.9 24.0 28.2 32.1 8.8 13.4 14.4 15.4 17.4 18.7 18.7 20.0 22.7 23.7 24.6 26.6 28.7 32.7 37.3 9.6 14.8 15.9 17.0 19.2 20.7 20.7 22.2 25.1 26.3 28.2 30.4 31.9 36.3 41.9
Dia. of wire for armour mm
0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.4 0.4
Thickness Overall diameter of Nominal Tolersheath ance mm
1.1 1.3 1.3 1.4 1.4 1.5 1.5 1.5 1.6 1.6 1.6 1.7 1.8 1.9 2.1 1.2 1.3 1.4 1.4 1.5 1.5 1.5 1.5 1.6 1.7 1.7 1.8 1.8 2.0 2.2 1.2 1.4 1.4 1.5 1.5 1.6 1.6 1.7 1.8 1.8 1.8 1.9 2.0 2.2 2.4 1.2 1.4 1.5 1.5 1.6 1.7 1.7 1.7 1.9 1.9 2.0 2.1 2.1 2.3 2.5
mm
11.1 15.1 15.9 16.9 18.5 19.7 19.7 20.7 23.0 23.8 24.6 26.3 27.6 30.9 35.7 11.7 15.8 16.9 17.7 19.6 20.7 20.7 21.8 24.3 25.3 26.1 28.0 29.1 33.7 38.4 12.7 17.7 18.7 19.9 21.9 23.4 23.4 24.9 27.8 28.8 29.7 31.9 34.2 39.0 44.0 13.5 19.1 20.4 21.5 23.9 25.6 25.6 27.1 30.4 31.6 33.7 36.5 38.0 42.8 48.8
±mm
0.6 0.8 0.8 0.8 0.9 0.9 0.9 0.9 1.0 1.0 1.0 1.1 1.1 1.2 1.4 0.7 0.8 0.8 0.8 0.9 0.9 0.9 1.0 1.0 1.1 1.1 1.1 1.2 1.3 1.5 0.7 0.8 0.9 0.9 1.0 1.0 1.0 1.0 1.1 1.2 1.2 1.3 1.3 1.5 1.6 0.7 0.9 0.9 0.9 1.0 1.1 1.1 1.1 1.2 1.2 1.3 1.4 1.4 1.6 1.8
Conductor Insulation Resistance Resistance (at 20℃) (at 20℃) (Max.) (Min.)
Test Voltage
Cable Weight Approx.
Ω/km
㏁-km
V/5min.
kg/km
26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02
1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 850 850 850 850 850 850 850 850 850 850 850 850 850 850 850
1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500
210 340 390 440 510 570 600 650 770 850 920 1,030 1,150 1,390 1,840 240 370 430 490 570 630 670 730 870 970 1,060 1,180 1,310 1,700 2,220 270 450 520 600 700 790 840 930 1,110 1,230 1,350 1,510 1,800 2,290 2,870 320 520 630 720 860 970 1,040 1,150 1,390 1,560 1,830 2,130 2,390 2,920 3,750
Instrumentation & Communication Cable
• •
●
• • •
NEK-606 (2009), IEC 60092-350, 353, 354, 376
mm2
EA
mm
1T 2T 3T 4T 5T 6T 7T 8T 10T 12T 14T 16T 19T 24T 32T 1T 2T 3T 4T 5T 6T 7T 8T 10T 12T 14T 16T 19T 24T 32T 1T 2T 3T 4T 5T 6T 7T 8T 10T 12T 14T 16T 19T 24T 32T 1T 2T 3T 4T 5T 6T 7T 8T 10T 12T 14T 16T 19T 24T 32T
0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5
7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7
1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2
mm
0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7
mm
1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.2 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.2 1.4 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.2 1.2 1.2 1.4 1.4 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.2 1.2 1.4 1.4 1.6
mm
7.8 12.1 12.9 14.2 15.7 17.8 17.8 19.1 21.7 23.0 24.0 25.6 28.5 31.6 36.3 8.3 13.0 13.8 15.2 16.9 19.2 19.2 20.6 23.4 24.8 26.0 28.5 30.8 34.1 39.6 9.4 14.9 15.9 17.6 19.6 22.2 22.2 23.9 28.1 29.7 31.1 33.1 35.8 40.2 46.2 10.2 16.3 17.4 19.3 21.5 24.5 24.5 26.3 30.8 32.7 34.2 36.4 39.8 44.2 51.5
Dia. of wire for armour mm
0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.4 0.4 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.4 0.4 0.4 0.4 0.4
Thickness Overall diameter of Nominal Tolersheath ance mm
1.2 1.3 1.4 1.4 1.5 1.6 1.6 1.6 1.7 1.8 1.8 1.9 2.0 2.1 2.3 1.2 1.4 1.4 1.5 1.5 1.6 1.6 1.7 1.8 1.8 1.9 2.0 2.1 2.2 2.5 1.2 1.4 1.5 1.6 1.6 1.7 1.7 1.8 2.0 2.0 2.1 2.2 2.3 2.5 2.7 1.3 1.5 1.5 1.6 1.7 1.8 1.8 1.9 2.1 2.2 2.2 2.3 2.5 2.6 2.9
mm
11.7 16.2 17.2 18.5 20.2 22.5 22.5 23.8 26.6 28.1 29.1 30.9 34.0 37.7 42.8 12.2 17.3 18.1 19.7 21.4 23.9 23.9 25.5 28.5 29.9 31.3 34.0 36.9 40.4 46.5 13.3 19.2 20.4 22.3 24.3 27.1 27.1 29.0 33.6 35.2 37.2 39.4 42.3 47.1 53.5 14.3 20.8 21.9 24.0 26.4 29.6 29.6 31.6 36.9 39.0 40.5 42.9 46.7 51.3 59.2
±mm
0.7 0.8 0.8 0.9 0.9 1.0 1.0 1.0 1.1 1.1 1.2 1.2 1.3 1.4 1.6 0.7 0.8 0.8 0.9 0.9 1.0 1.0 1.1 1.2 1.2 1.2 1.3 1.4 1.5 1.7 0.7 0.9 0.9 1.0 1.0 1.1 1.1 1.2 1.3 1.4 1.4 1.5 1.6 1.7 1.9 0.7 0.9 1.0 1.0 1.1 1.2 1.2 1.2 1.4 1.5 1.5 1.6 1.7 1.8 2.1
Conductor Insulation Resistance Resistance (at 20℃) (at 20℃) (Max.) (Min.)
Test Voltage
Cable Weight Approx.
Ω/km
㏁-km
V/5min.
kg/km
26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02
1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 850 850 850 850 850 850 850 850 850 850 850 850 850 850 850
1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500
240 390 460 540 620 730 770 850 1,010 1,140 1,250 1,390 1,680 2,090 2,620 270 440 510 610 700 820 870 970 1,160 1,300 1,450 1,710 2,030 2,420 3,130 310 530 640 760 880 1,030 1,100 1,230 1,590 1,780 2,070 2,300 2,620 3,230 4,070 370 640 770 930 1,100 1,290 1,390 1,560 2,080 2,360 2,620 2,920 3,430 4,130 5,400
Offshore Cable
LV Power & Lighting Cable
No.
Thickness Thickness Nominal of of dia. Insulation inner inner covering covering
Instrumentation & Communication Cable
Max. overall dia.
Earthing & Bonding wire
Max. No. of wires
VFD Cable
Conductor Nominal Area
Technical Information
No. of Triads
HV Power Cable
250V BFOU(c), 250V BFCU(c), 250V BFBU(c)
57
Halogen free & Mud resistant Offshore cable
Instrumentation & Communication Cable
Cable Designation (S3, S3/S7) 250V BFOU(i), BFCU(i), BFBU(i)
Application Standard - Design guide
: NEK-606 & IEC 60092-376
- Flame retardant
: IEC 60332-1 &
IEC 60332-3 Category A
250V BFOU(i)
- Fire resistance
: IEC 60331-21(90min)
IEC 60331-1,-2(120min)
- Halogen content
: IEC 60754-1, 0.5%↓
- Cold bend / impact
: CSA 22.2 No.03 (-40℃/-35℃)
- Mud resistant
: NEK-606 (Mud type only)
- Smoke light transmittance
: IEC 61034, 60%↑
- Sunlight (UV) resistant
: UL 1581
Construction Sectional view
Classification
Code
Conductor Fire resisting layer Insulation
B
Twisting Individual screen
Construction detail - Stranded tinned annealed copper wires as per IEC 60228, Class 2 - Mica/glass tape - HF EPR as per IEC 60092-351 - Two/Three Insulated cores shall be twisted together to form a pair/Triad
(i)
- CU/PS or AL/PS tape + Tinned copper drain wire - Twisted pairs / triads shall be cabled - Flame retardant & non-hygroscopic fillers may be used
Cabling
- Suitable tape(s) may be applied on the cabled core - A Filler may be applied to obtain a circular Cable
Inner covering Armor Sheath
F
- Flame retardant halogen free thermoset compound
O
- Braid of tinned copper wire (O) / bronze wire (B) /galvanized steel wire (C)
(B,C) U
- A suitable separator tape(s) may be applied under/over the armor - SHF2 or SHF Mud as per IEC 60092-359 - Outer sheath color : Grey (Non-IS Type) or Blue (IS Type) - Each Pair / Triad : Core color
Core identification
① Pair : Black, Light blue
② Triad : Black, Light blue, Brown
- Multi Pairs / Triads : Number printing on the insulation or numbered tape Note. Flexible cable (Class5 Conductor) can be supplied
58
Offshore Cable
Instrumentation & Communication Cable
• •
●
• • •
NEK-606 (2009), IEC 60092-350, 353, 354, 376
mm2
EA
mm
1P 2P 3P 4P 5P 6P 7P 8P 10P 12P 14P 16P 19P 24P 32P 1P 2P 3P 4P 5P 6P 7P 8P 10P 12P 14P 16P 19P 24P 32P 1P 2P 3P 4P 5P 6P 7P 8P 10P 12P 14P 16P 19P 24P 32P 1P 2P 3P 4P 5P 6P 7P 8P 10P 12P 14P 16P 19P 24P 32P
0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5
7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7
1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2
mm
0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7
mm
1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.2 1.4 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.2 1.2 1.2 1.4 1.4
mm
7.4 11.7 12.4 13.7 15.3 15.9 15.9 17.5 20.0 20.8 21.9 23.6 24.1 29.0 31.5 7.8 12.4 13.2 14.5 16.3 16.9 16.9 18.6 21.3 22.2 23.3 25.1 25.7 30.9 33.6 8.8 14.2 15.1 16.6 18.7 19.4 19.4 21.4 24.5 25.6 26.9 29.8 30.5 35.7 39.2 9.6 15.6 16.6 18.3 20.6 21.4 21.4 23.7 27.9 29.1 30.6 32.9 33.7 39.9 43.3
Dia. of wire for armour mm
0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.4 0.4 0.4
Thickness Overall diameter of Nominal Tolersheath ance mm
1.1 1.3 1.3 1.4 1.5 1.5 1.5 1.6 1.7 1.7 1.7 1.8 1.8 2.0 2.1 1.2 1.3 1.4 1.4 1.5 1.5 1.5 1.6 1.7 1.7 1.8 1.9 1.9 2.1 2.2 1.2 1.4 1.5 1.5 1.6 1.6 1.6 1.7 1.8 1.9 1.9 2.0 2.1 2.3 2.4 1.2 1.5 1.5 1.6 1.7 1.7 1.7 1.8 2.0 2.0 2.1 2.2 2.2 2.5 2.6
mm
11.1 15.8 16.5 18.0 19.8 20.4 20.4 22.2 24.9 25.7 26.8 28.7 29.2 34.5 37.6 11.7 16.5 17.5 18.8 20.8 21.4 21.4 23.3 26.2 27.1 28.4 30.4 31.0 37.0 39.9 12.7 18.5 19.6 21.1 23.4 24.1 24.1 26.3 29.6 30.9 32.2 35.3 36.6 42.2 45.9 13.5 20.1 21.1 23.0 25.5 26.3 26.3 28.8 33.4 34.6 36.7 39.2 40.0 46.8 50.4
Conductor Insulation Resistance Resistance (at 20℃) (at 20℃) (Max.) (Min.)
Test Voltage
Cable Weight Approx.
±mm
Ω/km
㏁-km
V/5min.
kg/km
0.6 0.8 0.8 0.8 0.9 0.9 0.9 1.0 1.0 1.1 1.1 1.2 1.2 1.3 1.4 0.7 0.8 0.8 0.9 0.9 0.9 0.9 1.0 1.1 1.1 1.2 1.2 1.2 1.4 1.5 0.7 0.9 0.9 0.9 1.0 1.0 1.0 1.1 1.2 1.2 1.3 1.4 1.4 1.6 1.7 0.7 0.9 0.9 1.0 1.1 1.1 1.1 1.2 1.3 1.3 1.4 1.5 1.5 1.7 1.8
26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02
1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 850 850 850 850 850 850 850 850 850 850 850 850 850 850 850
1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500
220 360 420 490 580 630 670 760 910 1,000 1,110 1,240 1,370 1,790 2,280 240 400 470 550 650 710 760 860 1,030 1,150 1,280 1,440 1,600 2,170 2,650 280 480 570 670 790 870 930 1,050 1,270 1,440 1,590 1,880 2,190 2,710 3,390 320 560 670 810 970 1,070 1,160 1,310 1,690 1,900 2,210 2,480 2,760 3,510 4,340
Offshore Cable
LV Power & Lighting Cable
No.
Thickness Thickness Nominal of of dia. Insulation inner inner covering covering
Instrumentation & Communication Cable
Max. overall dia.
Earthing & Bonding wire
Max. No. of wires
VFD Cable
Conductor Nominal Area
Technical Information
No. of Pairs
HV Power Cable
250V BFOU(i), 250V BFCU(i), 250V BFBU(i)
59
Halogen free & Mud resistant Offshore cable
Instrumentation & Communication Cable 250V BFOU(i), 250V BFCU(i), 250V BFBU(i) No. of Triads
Conductor Nominal Area
Max. No. of wires
Max. overall dia.
No.
mm2
EA
mm
1T 2T 3T 4T 5T 6T 7T 8T 10T 12T 14T 16T 19T 24T 32T 1T 2T 3T 4T 5T 6T 7T 8T 10T 12T 14T 16T 19T 24T 32T 1T 2T 3T 4T 5T 6T 7T 8T 10T 12T 14T 16T 19T 24T 32T 1T 2T 3T 4T 5T 6T 7T 8T 10T 12T 14T 16T 19T 24T 32T
0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5
60
Offshore Cable
7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7
1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2
Thickness Thickness Nominal of of dia. Insulation inner inner covering covering mm
0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7
mm
1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.4 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.2 1.4 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.2 1.2 1.2 1.4 1.4 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.2 1.2 1.2 1.4 1.4 1.6
mm
7.8 12.5 13.3 14.7 16.3 18.5 18.5 19.9 22.6 24.0 25.1 26.8 29.8 33.0 38.4 8.3 13.4 14.3 15.8 17.5 19.9 19.9 21.4 24.4 25.9 27.0 29.6 32.0 35.6 41.3 9.4 15.3 16.4 18.1 20.2 23.0 23.0 24.7 29.0 30.7 32.1 34.2 37.0 41.6 47.8 10.2 16.7 17.9 19.8 22.1 25.2 25.2 27.9 31.8 33.7 35.3 37.6 41.1 45.7 53.2
Dia. of wire for armour mm
0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.4 0.4 0.4 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.4 0.4 0.4 0.4 0.4
Thickness Overall diameter of Nominal Tolersheath ance mm
1.2 1.4 1.4 1.4 1.5 1.6 1.6 1.6 1.8 1.8 1.9 1.9 2.0 2.2 2.4 1.2 1.4 1.4 1.5 1.6 1.6 1.6 1.7 1.8 1.9 1.9 2.0 2.1 2.3 2.5 1.2 1.5 1.5 1.6 1.7 1.8 1.8 1.8 2.0 2.1 2.2 2.2 2.3 2.5 2.8 1.3 1.5 1.6 1.6 1.7 1.9 1.9 2.0 2.1 2.2 2.3 2.4 2.5 2.7 3.0
mm
11.7 16.8 17.6 19.0 20.8 23.2 23.2 24.6 27.7 29.1 30.4 32.1 35.3 39.3 45.1 12.2 17.7 18.6 20.3 22.2 24.6 24.6 26.3 29.5 31.2 32.3 35.1 38.1 42.1 48.2 13.3 19.8 20.9 22.8 25.1 28.1 28.1 29.8 34.5 36.8 38.4 40.5 43.5 48.5 55.3 14.3 21.2 22.6 24.5 27.0 30.5 30.5 33.4 37.9 40.0 41.8 44.3 48.0 53.0 61.1
±mm
0.7 0.8 0.8 0.9 0.9 1.0 1.0 1.0 1.1 1.2 1.2 1.3 1.4 1.5 1.7 0.7 0.8 0.9 0.9 1.0 1.0 1.0 1.1 1.2 1.2 1.3 1.4 1.4 1.6 1.7 0.7 0.9 0.9 1.0 1.1 1.1 1.1 1.2 1.3 1.4 1.5 1.5 1.6 1.8 2.0 0.7 0.9 1.0 1.0 1.1 1.2 1.2 1.3 1.4 1.5 1.6 1.6 1.7 1.9 2.1
Conductor Insulation Resistance Resistance (at 20℃) (at 20℃) (Max.) (Min.)
Test Voltage
Cable Weight Approx.
Ω/km
㏁-km
V/5min.
kg/km
26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02
1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 850 850 850 850 850 850 850 850 850 850 850 850 850 850 850
1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500
240 420 490 570 680 790 840 930 1,130 1,270 1,420 1,570 1,900 2,380 3,080 270 460 550 660 780 900 960 1,080 1,300 1,480 1,640 1,930 2,300 2,780 3,590 310 560 670 810 960 1,130 1,220 1,350 1,730 2,060 2,300 2,540 2,910 3,600 4,590 370 660 820 990 1,180 1,400 1,520 1,800 2,260 2,580 2,890 3,230 3,780 4,600 6,020
Instrumentation & Communication Cable
• •
●
• • •
HV Power Cable
NEK-606 (2009), IEC 60092-350, 353, 354, 376
Cable Designation LV Power & Lighting Cable
250V BFOU(i&c), BFCU(i&c), BFBU(i&c)
Application Standard - Design guide
: NEK-606 & IEC 60092-376
- Flame retardant
: IEC 60332-1 &
IEC 60332-3 Category A : IEC 60331-21(90min)
IEC 60331-1,-2(120min)
- Halogen content
: IEC 60754-1, 0.5%↓
- Cold bend / impact
: CSA 22.2 No.03 (-40℃/-35℃)
- Mud resistant
: NEK-606 (Mud type only)
- Smoke light transmittance
: IEC 61034, 60%↑
- Sunlight (UV) resistant
: UL 1581
Instrumentation & Communication Cable
250V BFOU(i&c)
- Fire resistance
Sectional view
Classification
Code
Conductor Fire resisting layer Insulation
Construction detail - Stranded tinned annealed copper wires as per IEC 60228, Class 2
B
Twisting Individual screen
Earthing & Bonding wire
Construction
- Mica/glass tape - HF EPR as per IEC 60092-351 - Two/Three Insulated cores shall be twisted together to form a pair/Triad
(i)
- CU/PS or AL/PS tape + Tinned copper drain wire - Twisted pairs / triads shall be cabled - Flame retardant & non-hygroscopic fillers may be used
Cabling
- Suitable tape(s) may be applied on the cabled core
VFD Cable
- A Filler may be applied to obtain a circular Cable Collective screen
(c)
- CU/PS or AL/PS tape + Tinned copper drain wire
Inner covering
F
- Flame retardant halogen free thermoset compound
O
- Braid of tinned copper wire (O) / bronze wire (B) / galvanized steel wire (C)
Armor Sheath
(B,C) U
- A suitable separator tape(s) may be applied under / over the armor - SHF2 or SHF Mud as per IEC 60092-359 - Outer sheath color : Grey (Non-IS Type) or Blue (IS Type) ① Pair : Black, Light blue
Technical Information
- Each Pair / Triad : Core color Core identification
② Triad : Black, Light blue, Brown
- Multi Pairs / Triads : Number printing on the insulation or numbered tape Note. Flexible cable (Class5 Conductor) can be supplied
Offshore Cable
61
Halogen free & Mud resistant Offshore cable
Instrumentation & Communication Cable 250V BFOU(i&c), 250V BFCU(i&c), 250V BFBU(i&c) No. of Pairs
Conductor Nominal Area
Max. No. of wires
Max. overall dia.
No.
mm2
EA
mm
2P 3P 4P 5P 6P 7P 8P 10P 12P 14P 16P 19P 24P 32P 2P 3P 4P 5P 6P 7P 8P 10P 12P 14P 16P 19P 24P 32P 2P 3P 4P 5P 6P 7P 8P 10P 12P 14P 16P 19P 24P 32P 2P 3P 4P 5P 6P 7P 8P 10P 12P 14P 16P 19P 24P 32P
0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5
62
Offshore Cable
7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7
1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2
Thickness Thickness Nominal of of dia. Insulation inner inner covering covering mm
0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7
mm
1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.2 1.4 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.2 1.2 1.2 1.4 1.4
mm
11.8 12.5 13.8 15.4 16.0 16.0 17.6 20.1 20.9 22.0 23.7 24.2 29.1 31.6 12.5 13.3 14.6 16.4 17.0 17.0 18.7 21.4 22.3 23.4 25.2 25.8 31.0 33.7 14.3 15.2 16.7 18.8 19.5 19.5 21.5 24.6 25.7 27.0 29.9 30.6 35.8 39.3 15.7 16.7 18.4 20.7 21.5 21.5 23.8 28.0 29.2 30.7 33.0 33.8 40.0 43.4
Dia. of wire for armour mm
0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.4 0.4 0.4
Thickness Overall diameter of Nominal Tolersheath ance mm
1.3 1.4 1.4 1.5 1.5 1.5 1.6 1.7 1.7 1.7 1.8 1.8 2.0 2.1 1.4 1.4 1.4 1.5 1.5 1.5 1.6 1.7 1.7 1.8 1.9 1.9 2.1 2.2 1.4 1.5 1.5 1.6 1.6 1.6 1.7 1.8 1.9 1.9 2.0 2.1 2.3 2.4 1.5 1.5 1.6 1.7 1.7 1.7 1.8 2.0 2.0 2.1 2.2 2.2 2.5 2.6
mm
15.9 16.8 18.1 19.9 20.5 20.5 22.3 25.0 25.8 26.9 28.8 29.3 34.6 37.7 16.8 17.6 18.9 20.9 21.5 21.5 23.4 26.3 27.2 28.5 30.5 31.1 37.1 40.0 18.6 19.7 21.2 23.5 24.2 24.2 26.4 29.7 31.0 32.3 35.4 36.7 42.3 46.0 20.2 21.2 23.1 25.6 26.4 26.4 28.9 33.5 34.7 36.8 39.3 40.1 46.9 50.5
±mm
0.8 0.8 0.8 0.9 0.9 0.9 1.0 1.1 1.1 1.1 1.2 1.2 1.3 1.4 0.8 0.8 0.9 0.9 0.9 0.9 1.0 1.1 1.1 1.2 1.2 1.2 1.4 1.5 0.9 0.9 0.9 1.0 1.0 1.0 1.1 1.2 1.2 1.3 1.4 1.4 1.6 1.7 0.9 0.9 1.0 1.1 1.1 1.1 1.2 1.3 1.3 1.4 1.5 1.5 1.7 1.8
Conductor Insulation Resistance Resistance (at 20℃) (at 20℃) (Max.) (Min.)
Test Voltage
Cable Weight Approx.
Ω/km
㏁-km
V/5min.
kg/km
26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02
1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 850 850 850 850 850 850 850 850 850 850 850 850 850 850
1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500
380 440 510 600 650 690 780 930 1,030 1,130 1,270 1,400 1,820 2,310 420 490 570 670 730 780 880 1,060 1,170 1,310 1,470 1,630 2,200 2,690 500 590 690 810 890 950 1,080 1,300 1,470 1,630 1,920 2,230 2,750 3,440 590 700 840 990 1,100 1,180 1,340 1,720 1,930 2,250 2,520 2,800 3,550 4,390
Instrumentation & Communication Cable
• •
●
• • •
NEK-606 (2009), IEC 60092-350, 353, 354, 376
mm2
EA
mm
2T 3T 4T 5T 6T 7T 8T 10T 12T 14T 16T 19T 24T 32T 2T 3T 4T 5T 6T 7T 8T 10T 12T 14T 16T 19T 24T 32T 2T 3T 4T 5T 6T 7T 8T 10T 12T 14T 16T 19T 24T 32T 2T 3T 4T 5T 6T 7T 8T 10T 12T 14T 16T 19T 24T 32T
0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5
7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7
1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2
mm
0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7
mm
1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.4 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.2 1.2 1.4 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.2 1.2 1.2 1.4 1.4 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.2 1.2 1.2 1.4 1.4 1.6
mm
12.6 13.4 14.8 16.4 18.6 18.6 20.0 22.7 24.1 25.2 26.9 29.9 33.1 38.5 13.5 14.4 15.9 17.6 20.0 20.0 21.5 24.5 26.0 27.9 29.7 32.1 35.7 41.4 15.4 16.5 18.2 20.3 23.1 23.1 24.8 29.1 30.8 32.2 34.3 37.1 41.7 47.9 16.8 18.0 19.9 22.2 25.3 25.3 28.0 31.9 33.8 35.4 37.7 41.2 45.8 53.3
Dia. of wire for armour mm
0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.4 0.4 0.4 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.4 0.4 0.4 0.4 0.4
Thickness Overall diameter of Nominal Tolersheath ance mm
1.4 1.4 1.4 1.5 1.6 1.6 1.7 1.8 1.8 1.9 1.9 2.0 2.2 2.4 1.4 1.4 1.5 1.6 1.7 1.7 1.7 1.8 1.9 2.0 2.0 2.2 2.3 2.5 1.5 1.5 1.6 1.7 1.8 1.8 1.8 2.0 2.1 2.2 2.2 2.4 2.5 2.8 1.5 1.6 1.6 1.7 1.9 1.9 2.0 2.1 2.2 2.3 2.4 2.5 2.7 3.0
mm
16.9 17.7 19.1 20.9 23.3 23.3 24.9 27.8 29.2 30.5 32.2 35.4 39.4 45.2 17.8 18.7 20.4 22.3 24.9 24.9 26.4 29.6 31.3 33.4 35.2 38.4 42.2 48.3 19.9 21.0 22.9 25.2 28.2 28.2 29.9 34.6 36.9 38.5 40.6 43.8 48.6 55.4 21.3 22.7 24.6 27.1 30.6 30.6 33.5 38.0 40.1 41.9 44.4 48.1 53.1 61.2
±mm
0.8 0.8 0.9 0.9 1.0 1.0 1.0 1.1 1.2 1.2 1.3 1.4 1.5 1.7 0.8 0.9 0.9 1.0 1.0 1.0 1.1 1.2 1.2 1.3 1.4 1.5 1.6 1.7 0.9 0.9 1.0 1.1 1.1 1.1 1.2 1.3 1.4 1.5 1.5 1.6 1.8 2.0 0.9 1.0 1.0 1.1 1.2 1.2 1.3 1.4 1.5 1.6 1.6 1.7 1.9 2.1
Conductor Insulation Resistance Resistance (at 20℃) (at 20℃) (Max.) (Min.)
Test Voltage
Cable Weight Approx.
Ω/km
㏁-km
V/5min.
kg/km
26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 26.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 19.3 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 12.9 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02 8.02
1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,170 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,050 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 1,020 850 850 850 850 850 850 850 850 850 850 850 850 850 850
1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500 1,500
430 510 590 690 810 870 970 1,160 1,300 1,450 1,600 1,930 2,420 3,110 480 570 680 800 940 1,000 1,110 1,330 1,510 1,780 1,960 2,350 2,820 3,630 580 690 830 990 1,160 1,250 1,380 1,770 2,090 2,330 2,580 2,970 3,640 4,640 680 850 1,010 1,200 1,430 1,560 1,830 2,290 2,620 2,930 3,270 3,830 4,650 6,080
Offshore Cable
LV Power & Lighting Cable
No.
Thickness Thickness Nominal of of dia. Insulation inner inner covering covering
Instrumentation & Communication Cable
Max. overall dia.
Earthing & Bonding wire
Max. No. of wires
VFD Cable
Conductor Nominal Area
Technical Information
No. of Triads
HV Power Cable
250V BFOU(i&c), 250V BFCU(i&c), 250V BFBU(i&c)
63
Earthing & Bonding wire
0.6/1kV UX, FX - UX 0.6/1kV RX
65 ~ 66
Earthing & Bonding wire
• • •
Earthing & Bonding wire
●
• •
HV Power Cable
NEK-606 (2009), IEC 60092-350, 353, 354, 376
Cable Designation (P15) LV Power & Lighting Cable
0.6/1kV UX, FX - UX , RX
Application Standard - Design guide
: NEK-606 & IEC 60092-353
- Flame retardant
: IEC 60332-1 & IEC 60332-3 Category A
- Halogen content
: IEC 60754-1, 0.5%↓
- Cold bend / impact
: CSA 22.2 No.03 (-40℃/-35℃)
- Smoke light transmittance
: IEC 61034, 60%↑
- Sunlight (UV) resistant
: UL 1581
Instrumentation & Communication Cable
0.6/1KV RX
Construction Classification
Code
Construction detail
Conductor
Stranded tinned annealed copper wires as per IEC 60228, Class 2
Insulation
RX
HF EPR as per IEC 60092-351
UX
SHF2 as per IEC 60092-359
-
Earthing & Bonding wire
Sectional view
Insulation color : Yellow/Green (Green base with yellow strip) or Green
No.
1
Conductor Nominal Area
Min. No. of wires
Max. overall dia.
mm2
EA
mm
1.0 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300
7 7 7 7 7 7 7 7 7 19 19 19 37 37 37 61 61
1.4 1.7 2.2 2.7 3.3 4.2 5.3 6.6 7.9 9.1 11.0 12.9 14.5 16.2 18.0 20.6 23.1
Thickness of Insulation mm
2.0 2.0 2.0 2.0 2.0 2.0 2.1 2.4 2.4 2.7 3.0 3.0 3.1 3.4 3.7 4.0 4.3
Overall diameter Nominal
Tolerance
mm
±mm
5.5 5.8 6.2 6.7 7.3 8.2 9.4 11.3 12.4 14.4 16.7 18.6 20.3 22.4 24.9 28.1 31.0
0.5 0.5 0.5 0.6 0.6 0.6 0.7 0.8 0.8 0.9 1.0 1.0 1.1 1.2 1.3 1.4 1.5
Conductor Resistance (at 20℃) (Max.)
Insulation Resistance (at 20℃) (Min.)
Test Voltage
Cable Weight
Ω/km
㏁-km
V/5min.
kg/km
18.2 12.2 7.56 4.70 3.11 1.84 1.16 0.734 0.529 0.391 0.270 0.195 0.154 0.126 0.100 0.0762 0.0607
22 20 18 15 13 11 10 9 8 8 7 6 6 6 6 5 5
3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500 3,500
50 58 71 89 114 160 230 350 450 600 840 1,110 1,360 1,660 2,080 2,690 3,330
Offshore Cable
Technical Information
No. of Cores
VFD Cable
0.6/1kV UX (CLASS2 CONDUCTOR)
65
Halogen free & Mud resistant Offshore cable
Earthing & Bonding wire 0.6/1kV FX-UX (CLASS5 CONDUCTOR) No. of Cores
No.
Conductor Nominal Area
Min. No. of wires
Max. overall dia.
mm2
EA
mm
1.0
0.21
Thickness of Insulation mm
1.5
Overall diameter Nominal
Tolerance
mm
±mm
2.0
5.5
0.5
Conductor Resistance (at 20℃) (Max.)
Insulation Resistance (at 20℃) (Min.)
Test Voltage
Cable Weight
Ω/km
㏁-km
V/5min.
kg/km
20.0
22
3,500
50
1.5
0.26
1.8
2.0
5.8
0.5
13.7
20
3,500
58
2.5
0.26
2.4
2.0
6.3
0.6
8.21
17
3,500
72
1
4
0.31
3.0
2.0
6.8
0.6
5.09
15
3,500
91
6
0.31
3.9
2.0
7.4
0.6
3.39
13
3,500
115
10
0.41
5.1
2.0
8.3
0.6
1.95
11
3,500
160
16
0.41
6.3
2.1
10.0
0.7
1.24
9
3,500
230
25
0.41
7.8
2.4
12.1
0.8
0.795
8
3,500
340
35
0.41
9.2
2.4
13.3
0.8
0.565
7
3,500
450
50
0.41
11.0
2.7
15.5
0.9
0.393
7
3,500
630
70
0.51
13.1
3.0
18.0
1.0
0.277
7
3,500
880
95
0.51
15.1
3.1
19.9
1.1
0.210
6
3,500
1,110
120
0.51
17.0
3.1
21.7
1.2
0.164
5
3,500
1,370
150
0.51
19.0
3.4
24.1
1.3
0.132
5
3,500
1,710
185
0.51
21.0
3.7
26.2
1.3
0.108
5
3,500
2,060
240
0.51
24.0
4.0
29.5
1.5
0.0817
5
3,500
2,680
300
0.51
27.0
4.3
32.7
1.6
0.0654
5
3,500
3,360
Conductor Resistance (at 20℃) (Max.)
Insulation Resistance (at 20℃) (Min.)
Test Voltage
Cable Weight
Ω/km
㏁-km
V/5min.
kg/km
0.6/1kV RX No. of Cores
No.
1
66
Conductor Nominal Area
Min. No. of wires
mm2
EA
Max. overall dia. mm
Thickness of Insulation mm
Overall diameter Nominal
Tolerance
mm
±mm
1.0
7
1.4
2.0
5.5
0.5
18.2
22
3,500
47
1.5
7
1.7
2.0
5.8
0.5
12.2
20
3,500
54
2.5
7
2.2
2.0
6.2
0.5
7.56
18
3,500
67
4
7
2.7
2.0
6.7
0.6
4.70
15
3,500
85
6
7
3.3
2.0
7.3
0.6
3.11
13
3,500
109
10
7
4.2
2.0
8.2
0.6
1.84
11
3,500
150
16
7
5.3
2.1
9.4
0.7
1.16
10
3,500
220
25
7
6.6
2.3
11.1
0.7
0.734
9
3,500
330
35
7
7.9
2.4
12.4
0.8
0.529
8
3,500
440
50
19
9.1
2.7
14.4
0.9
0.391
8
3,500
590
70
19
11.0
2.9
16.5
1.0
0.270
7
3,500
810
95
19
12.9
3.0
18.6
1.0
0.195
6
3,500
1,090
120
37
14.5
3.1
20.3
1.1
0.154
6
3,500
1,340
150
37
16.2
3.4
22.4
1.2
0.126
6
3,500
1,630
185
37
18.0
3.7
24.9
1.3
0.100
6
3,500
203
240
61
20.6
4.0
28.1
1.4
0.0762
5
3,500
2,640
300
61
23.1
4.3
31.0
1.5
0.0607
5
3,500
3,270
Offshore Cable
VFD Cable
0.6/1kV(1.8/3kV) RFOU(VFD), FX-RFOU(VFD)
68 ~ 69
0.6/1kV(1.8/3kV) BFOU(VFD), FX-BFOU(VFD)
70 ~ 71
Halogen free & Mud resistant Offshore cable
VFD Cable
Cable Designation 0.6/1kV(1.8/3kV) RFOU(VFD), FX-RFOU(VFD)
Application Standard - Design guide
: NEK-606 & IEC 60092-353
- Flame retardant
: IEC 60332-1 &
0.6/1kV(1.8/3kV) RFOU(VFD)
IEC 60332-3 Category A
- Halogen content
: IEC 60754-1, 0.5%↓
- Cold bend / impact
: CSA 22.2 No.03 (-40℃/-35℃)
- Mud resistant
: NEK-606 (Mud type only)
- Smoke light transmittance
: IEC 61034, 60%↑
- Sunlight (UV) resistant
: UL 1581
Construction Sectional view
Classification
Code
Conductor Insulation
Construction detail - Stranded tinned annealed copper wires as per IEC 60228, Class 2
R
- HF EPR as per IEC 60092-351 - Insulated cores shall be cabled - Flame retardant & non-hygroscopic fillers may be used
Cabling
- Suitable tape(s) may be applied on the cabled core - A Filler may be applied to obtain a circular Cable
Inner covering
F (VFD)
Armor (Screen)
- Flame retardant halogen free thermoset compound - CU/PS tape - Braid of tinned copper wire
O
- Coverage density of braid shall be not less than 100%. - A suitable separator tape(s) may be applied over the armor
Sheath Core identification Note. 1. Flexible cable (Class5 Conductor) can be supplied
2. Earth core(G/Y) : Yellow/Green(Green base color with yellow stripe)
68
Offshore Cable
U
- SHF2 or SHF Mud as per IEC 60092-359 - Outer sheath color : Black - 3C+3E : Off-white, Black, Red + G/Y
VFD Cable
• • • •
●
•
NEK-606 (2009), IEC 60092-350, 353, 354, 376
0.6/1kV(1.8/3kV) RFOU(VFD)
mm2
25 6 35 6 50 10 70 16 95 16 120 25 150 25 185 35 240 50
ea.
7 7 7 7 19 7 19 7 19 7 37 7 37 7 37 7 61 19
mm
Thickness Thickness Nominal of of dia. Insulation inner inner covering covering mm
6.6 3.3 7.9 3.3 9.1 4.2 11.0 5.3 12.9 5.3 14.5 6.6 16.2 6.6 18.0 7.9 20.6 9.1
2.2 1.0 2.2 1.0 2.2 1.0 2.2 1.0 2.4 1.0 2.4 1.2 2.4 1.2 2.4 1.2 2.4 1.4
mm
mm
Dia. of wire for armour mm
Thickness Overall diameter of Nominal Tolersheath ance mm
mm
Conductor Insulation Resistance Resistance (at 20℃) (at 20℃) (Max.) (Min.)
Test Voltage
Cable Weight
±mm
Ω/km
㏁-km
V/5min.
kg/km
1.0
25.7
0.3
1.9
31.7
1.6
28.7
0.3
2.0
34.9
1.7
1.2
31.5
0.4
2.2
38.5
1.8
1.2
35.4
0.4
2.3
42.6
2.0
1.4
40.7
0.4
2.5
48.3
2.2
1.4
44.2
0.4
2.7
52.2
2.4
1.4
47.6
0.4
2.8
55.8
2.5
1.6
51.9
0.4
3.0
60.5
2.7
1.6
57.7
0.4
3.2
66.7
3.0
830 790 730 790 640 640 550 530 510 530 460 510 420 510 380 440 340 440
6,500 3,500 6,500 3,500 6,500 3,500 6,500 3,500 6,500 3,500 6,500 3,500 6,500 3,500 6,500 3,500 6,500 3,500
1,970
1.2
0.734 3.110 0.529 3.110 0.391 1.840 0.270 1.160 0.195 1.160 0.154 0.734 0.126 0.734 0.1000 0.5290 0.0762 0.3910
HV Power Cable
3C +3E 3C +3E 3C +3E 3C +3E 3C +3E 3C +3E 3C +3E 3C +3E 3C +3E
Max. Dia.
2,420 3,160 4,150
LV Power & Lighting Cable
No.
Conductor Nominal Min. Area Number of wires
5,330 6,540 7,590 9,230 11,690
Instrumentation & Communication Cable
No. of Cores
0.6/1kV(1.8/3kV) FX-RFOU(VFD)
mm2
25 6 35 6 50 10 70 16 95 16 120 25 150 25 185 35 240 50
Max. overall dia.
mm
mm
0.41 0.31 0.41 0.31 0.41 0.41 0.51 0.41 0.51 0.41 0.51 0.41 0.51 0.41 0.51 0.41 0.51 0.41
7.8 3.9 9.2 3.9 11.0 5.1 13.1 6.3 15.1 6.3 17.0 7.8 19.0 7.8 21.0 9.2 24.0 11.0
Thickness Thickness Nominal of of dia. Insulation inner inner covering covering mm
2.2 1.0 2.2 1.0 2.2 1.0 2.2 1.0 2.4 1.0 2.4 1.2 2.4 1.2 2.4 1.2 2.4 1.4
mm
mm
Dia. of wire for armour mm
Thickness Overall diameter of Nominal Tolersheath ance mm
mm
Conductor Insulation Resistance Resistance (at 20℃) (at 20℃) (Max.) (Min.)
Test Voltage
Cable Weight
±mm
Ω/km
㏁-km
V/5min.
kg/km
1.2
28.3
0.3
2.0
34.5
1.7
31.3
0.4
2.1
38.1
1.8
1.2
34.7
0.4
2.3
41.9
2.0
1.4
39.2
0.4
2.5
46.8
2.2
1.4
44.0
0.4
2.7
52.0
2.4
1.4
47.8
0.4
2.8
56.0
2.5
1.6
52.1
0.4
3.0
60.7
2.7
1.6
56.2
0.4
3.1
65.0
2.9
1.6
63.1
0.4
3.4
72.5
3.2
750 790 650 790 570 630 490 470 470 470 420 450 380 450 350 390 310 380
6,500 3,500 6,500 3,500 6,500 3,500 6,500 3,500 6,500 3,500 6,500 3,500 6,500 3,500 6,500 3,500 6,500 3,500
2,140
1.2
0.795 3.390 0.565 3.390 0.393 1.950 0.277 1.240 0.210 1.240 0.164 0.795 0.132 0.795 0.108 0.565 0.0817 0.393
Earthing & Bonding wire
3C +3E 3C +3E 3C +3E 3C +3E 3C +3E 3C +3E 3C +3E 3C +3E 3C +3E
Max. dia. of wires
2,710 3,520 4,550 5,640 6,880 8,120
VFD Cable
No.
Conductor Nominal Area
9,620 12,390
Technical Information
No. of Cores
Offshore Cable
69
Halogen free & Mud resistant Offshore cable
VFD Cable
Cable Designation 0.6/1kV(1.8/3kV) BFOU(VFD), FX-BFOU(VFD)
Application Standard - Design guide
: NEK-606 & IEC 60092-353
- Flame retardant
: IEC 60332-1 &
IEC 60332-3 Category A
0.6/1kV(1.8/3kV) BFOU(VFD)
- Fire resistance
: IEC 60331-21(90min)
IEC 60331-1,-2(120min)
- Halogen content
: IEC 60754-1, 0.5%↓
- Cold bend / impact
: CSA 22.2 No.03 (-40℃/-35℃)
- Mud resistant
: NEK-606 (Mud type only)
- Smoke light transmittance
: IEC 61034, 60%↑
- Sunlight (UV) resistant
: UL 1581
Construction Sectional view
Classification
Code
Conductor Fire resisting layer Insulation
Construction detail - Stranded tinned annealed copper wires as per IEC 60228, Class 2
B
- Mica/glass tape - HF EPR as per IEC 60092-351 - Insulated cores shall be cabled - Flame retardant & non-hygroscopic fillers may be used
Cabling
- Suitable tape(s) may be applied on the cabled core - A Filler may be applied to obtain a circular Cable
Inner covering
F (VFD)
Armor (Screen)
- Flame retardant halogen free thermoset compound - CU/PS tape - Braid of tinned copper wire
O
- Coverage density of braid shall be not less than 100% - A suitable separator tape(s) may be applied over the armor
Sheath Core identification Note. 1. Flexible cable (Class5 Conductor) can be supplied
2. Earth core(G/Y) : Yellow/Green(Green base color with yellow stripe)
70
Offshore Cable
U
- SHF2 or SHF Mud as per IEC 60092-359 - Outer sheath color : Black - 3C+3E : Off-white, Black, Red + G/Y
VFD Cable
• • • •
●
•
NEK-606 (2009), IEC 60092-350, 353, 354, 376
0.6/1kV(1.8/3kV) BFOU(VFD)
mm2
25 6 35 6 50 10 70 16 95 16 120 25 150 25 185 35 240 50
ea.
7 7 7 7 19 7 19 7 19 7 37 7 37 7 37 7 61 19
mm
Thickness Thickness Nominal of of dia. Insulation inner inner covering covering mm
6.6 3.3 7.9 3.3 9.1 4.2 11.0 5.3 12.9 5.3 14.5 6.6 16.2 6.6 18.0 7.9 20.6 9.1
2.2 1.0 2.2 1.0 2.2 1.0 2.2 1.0 2.4 1.0 2.4 1.2 2.4 1.2 2.4 1.2 2.4 1.4
mm
mm
Dia. of wire for armour mm
Thickness Overall diameter of Nominal Tolersheath ance mm
mm
Conductor Insulation Resistance Resistance (at 20℃) (at 20℃) (Max.) (Min.)
Test Voltage
Cable Weight
±mm
Ω/km
㏁-km
V/5min.
kg/km
1.0
26.8
0.3
2.0
33.0
1.6
29.8
0.4
2.1
36.6
1.8
1.2
32.8
0.4
2.2
39.8
1.9
1.2
36.7
0.4
2.4
44.1
2.1
1.4
42.0
0.4
2.6
49.8
2.3
1.4
45.5
0.4
2.7
53.5
2.4
1.6
49.3
0.4
2.9
57.7
2.6
1.6
53.4
0.4
3.0
62.0
2.8
1.6
59.0
0.4
3.3
68.2
3.0
830 790 730 790 640 640 550 530 510 530 460 510 420 510 380 440 340 440
6,500 3,500 6,500 3,500 6,500 3,500 6,500 3,500 6,500 3,500 6,500 3,500 6,500 3,500 6,500 3,500 6,500 3,500
2,070
1.2
0.734 3.110 0.529 3.110 0.391 1.840 0.270 1.160 0.195 1.160 0.154 0.734 0.126 0.734 0.100 0.529 0.0762 0.391
HV Power Cable
3C +3E 3C +3E 3C +3E 3C +3E 3C +3E 3C +3E 3C +3E 3C +3E 3C +3E
Max. Dia.
2,630 3,270 4,300
LV Power & Lighting Cable
No.
Conductor Nominal Min. Area Number of wires
5,490 6,690 7,800 9,420 11,900
Instrumentation & Communication Cable
No. of Cores
0.6/1kV(1.8/3kV) FX-BFOU(VFD)
mm2
25 6 35 6 50 10 70 16 95 16 120 25 150 25 185 35 240 50
Max. overall dia.
mm
mm
0.41 0.31 0.41 0.31 0.41 0.41 0.51 0.41 0.51 0.41 0.51 0.41 0.51 0.41 0.51 0.41 0.51 0.41
7.8 3.9 9.2 3.9 11.0 5.1 13.1 6.3 15.1 6.3 17.0 7.8 19.0 7.8 21.0 9.2 24.0 11.0
Thickness Thickness Nominal of of dia. Insulation inner inner covering covering mm
2.2 1.0 2.2 1.0 2.2 1.0 2.2 1.0 2.4 1.0 2.4 1.2 2.4 1.2 2.4 1.2 2.4 1.4
mm
mm
Dia. of wire for armour mm
Thickness Overall diameter of Nominal Tolersheath ance mm
mm
Conductor Insulation Resistance Resistance (at 20℃) (at 20℃) (Max.) (Min.)
Test Voltage
Cable Weight
±mm
Ω/km
㏁-km
V/5min.
kg/km
1.2
29.3
0.3
2.1
35.7
1.7
32.4
0.4
2.2
39.4
1.9
1.2
35.8
0.4
2.3
43.0
2.0
1.4
41.6
0.4
2.6
49.4
2.3
1.4
45.0
0.4
2.7
53.0
2.4
1.6
50.2
0.4
2.9
58.6
2.6
1.6
53.2
0.4
3.0
61.8
2.8
1.6
57.3
0.4
3.2
66.3
3.0
1.8
65.6
0.4
3.5
75.2
3.3
750 790 650 790 570 630 490 470 470 470 420 450 380 450 350 390 310 380
6,500 3,500 6,500 3,500 6,500 3,500 6,500 3,500 6,500 3,500 6,500 3,500 6,500 3,500 6,500 3,500 6,500 3,500
2,240
1.2
0.795 3.390 0.565 3.390 0.393 1.950 0.277 1.240 0.210 1.240 0.164 0.795 0.132 0.795 0.108 0.565 0.0817 0.393
Earthing & Bonding wire
3C +3E 3C +3E 3C +3E 3C +3E 3C +3E 3C +3E 3C +3E 3C +3E 3C +3E
Max. dia. of wires
2,840 3,640 4,870 5,770 7,210 8,300
VFD Cable
No.
Conductor Nominal Area
9,840 12,830
Technical Information
No. of Cores
Offshore Cable
71
Technical Information
Electrical Data
73 ~ 81
Voltage Rating Selection
82
Test Methods & Equipment
83
Installation Recommendations
85 ~ 89
Core Identification
90
Handling, Installation Method & Notice
91
Certificates Approved
92
Class Type Approval
93
Technical Information
• • • • •
Technical Information
●
NEK-606 (2009), IEC 60092-350, 353, 354, 376
ELECTRICAL DATA
Conductor temperature
HV Power Cable
1. Current rating for continuous 90℃ Single core (A)
Two core (A)
Three core & four core (A)
1 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300
18 23 30 40 52 72 96 127 157 196 242 293 339 389 444 522 601
15 20 26 34 44 61 82 108 133 167 206 249 288 331 377 444 511
13 16 21 28 36 50 67 89 110 137 169 205 237 273 311 366 420
Instrumentation & Communication Cable
LV Power & Lighting Cable
Nominal cross-sectional area (mm2)
NOTES)
N
Where, I1 : Current for single core cable N : Number of cores
No. of cores
1.0SQMM
1.5SQMM
2.5SQMM
5 7 9 12 14 16 19 24 30 37 44
11 9 9 8 7 7 7 6 6 5 5
13 12 11 10 10 9 9 8 7 7 7
18 16 14 13 12 12 11 10 10 9 8
VFD Cable
I1 3
Maximum conductor temperature ℃
35
40
45
50
55
60
65
70
75
80
90
1.10
1.05
1.00
0.94
0.88
0.82
0.74
0.67
0.58
0.47
Technical Information
I=
Earthing & Bonding wire
1. Maximum permissible service temperature of the conductor is 90℃ 2. The current ratings given above are based on an ambient air temperature of 45℃ 3. The current ratings given above are for 6 cables of less bunched or laid together in flat formation. When more than 6 cables are bunched or laid close together, the current ratings given above should be multiplied correction factor 0.85. In case of cables not being loaded simultaneously, consideration of the actual loading appertaining is permitted 4. For cables with more than 4 core cables, the current ratings are given by the Formula;
Correction factors for various ambient air temperature
Offshore Cable
73
Halogen free & Mud resistant Offshore cable
Technical Information ELECTRICAL DATA 2. Capacitance, Inductance, Reactance, Impedance Data 3.6/6kV RFOU, 3.6/6kV RFCU, 3.6/6kV RFBU Single core cable Nominal Capacitance Area C mm2
㎌/km
10 16 25 35 50 70 95 120 150 185 240 300
0.247 0.284 0.328 0.362 0.408 0.466 0.528 0.581 0.624 0.695 0.742 0.770
Multi core cable
Inductance L
Reactance X 50 Hz
Reactance X 60 Hz
mH / km
Ω/km
Ω/km
Ω/km
Ω/km
㎌/km
0.144 0.136 0.128 0.123 0.118 0.112 0.108 0.104 0.102 0.099 0.097 0.096
0.173 0.164 0.154 0.148 0.142 0.135 0.129 0.125 0.123 0.119 0.117 0.115
2.351 1.485 0.945 0.686 0.512 0.362 0.273 0.224 0.193 0.165 0.140 0.126
2.353 1.488 0.949 0.691 0.518 0.370 0.282 0.234 0.205 0.177 0.154 0.141
0.247 0.284 0.328 0.362 0.408 0.466 0.528 0.581 0.624 0.695 0.742 -
0.458 0.434 0.409 0.393 0.375 0.358 0.343 0.332 0.326 0.317 0.310 0.305
Impedance Impedance Capacitance Z Z C at 50 Hz 90℃ at 60 Hz 90℃
Inductance L
Reactance X 50 Hz
Reactance X 60 Hz
mH / km
Ω/km
Ω/km
Ω/km
Ω/km
0.102 0.096 0.091 0.088 0.085 0.082 0.079 0.077 0.076 0.074 0.073 -
0.122 0.115 0.109 0.106 0.102 0.098 0.095 0.093 0.091 0.089 0.088 -
2.348 1.482 0.940 0.680 0.506 0.354 0.263 0.213 0.181 0.151 0.125 -
2.349 1.484 0.942 0.683 0.509 0.358 0.268 0.219 0.187 0.159 0.134 -
0.324 0.306 0.290 0.281 0.270 0.260 0.252 0.246 0.242 0.237 0.234 -
Impedance Impedance Z Z at 50 Hz 90℃ at 60 Hz 90℃
6/10kV RFOU, 6/10kV RFCU, 6/10kV RFBU Single core cable Nominal Capacitance Area C mm2
㎌/km
16 25 35 50 70 95 120 150 185 240 300
0.228 0.261 0.287 0.321 0.365 0.411 0.450 0.484 0.535 0.591 0.651
Multi core cable Impedance Impedance Capacitance Z C Z at 50 Hz 90℃ at 60 Hz 90℃
Inductance L
Reactance X 50 Hz
Reactance X 60 Hz
mH / km
Ω/km
Ω/km
Ω/km
Ω/km
㎌/km
0.141 0.134 0.128 0.123 0.116 0.111 0.109 0.106 0.104 0.101 0.098
0.170 0.160 0.153 0.147 0.140 0.134 0.130 0.127 0.124 0.121 0.117
1.486 0.945 0.687 0.513 0.363 0.275 0.226 0.195 0.167 0.143 0.128
1.489 0.950 0.692 0.520 0.371 0.284 0.237 0.207 0.181 0.158 0.143
0.228 0.261 0.287 0.321 0.365 0.411 0.450 0.484 0.535 0.591 -
0.450 0.425 0.407 0.390 0.370 0.355 0.346 0.337 0.330 0.321 0.311
Inductance L
Reactance X 50 Hz
Reactance X 60 Hz
mH / km
Ω/km
Ω/km
Ω/km
Ω/km
0.105 0.099 0.096 0.092 0.088 0.085 0.083 0.081 0.079 0.077 -
0.126 0.119 0.115 0.110 0.106 0.102 0.099 0.097 0.095 0.092 -
1.483 0.941 0.681 0.507 0.355 0.265 0.215 0.183 0.153 0.127 -
1.484 0.943 0.684 0.511 0.360 0.271 0.222 0.190 0.162 0.137 -
0.335 0.316 0.305 0.292 0.280 0.270 0.263 0.258 0.251 0.245 -
Impedance Impedance Z Z at 50 Hz 90℃ at 60 Hz 90℃
8.7/15kV RFOU, 8.7/15kV RFCU, 8.7/15kV RFBU Single core cable Nominal Capacitance Area C mm2
㎌/km
25 35 50 70 95 120 150 185 240 300
0.215 0.235 0.261 0.295 0.330 0.360 0.386 0.424 0.468 0.514
74
Offshore Cable
Multi core cable
Inductance L
Reactance X 50 Hz
Reactance X 60 Hz
mH / km
Ω/km
Ω/km
Ω/km
Ω/km
㎌/km
0.139 0.133 0.128 0.121 0.117 0.114 0.111 0.107 0.104 0.102
0.167 0.160 0.153 0.145 0.140 0.137 0.133 0.129 0.125 0.122
0.946 0.688 0.515 0.365 0.277 0.229 0.198 0.169 0.145 0.131
0.951 0.693 0.522 0.374 0.288 0.241 0.211 0.184 0.161 0.147
0.215 0.235 0.261 0.295 0.330 0.360 0.386 0.424 0.468 -
0.443 0.424 0.406 0.386 0.371 0.362 0.353 0.341 0.332 0.324
Impedance Impedance Capacitance Z Z C at 50 Hz 90℃ at 60 Hz 90℃
Inductance L
Reactance X 50 Hz
Reactance X 60 Hz
mH / km
Ω/km
Ω/km
Ω/km
Ω/km
0.108 0.104 0.099 0.095 0.091 0.088 0.086 0.084 0.082 -
0.130 0.125 0.119 0.114 0.109 0.106 0.104 0.101 0.098 -
0.942 0.682 0.508 0.357 0.267 0.217 0.185 0.156 0.130 -
0.945 0.686 0.513 0.363 0.274 0.225 0.194 0.166 0.141 -
0.344 0.330 0.316 0.302 0.290 0.281 0.275 0.267 0.260 -
Impedance Impedance Z Z at 50 Hz 90℃ at 60 Hz 90℃
Technical Information
• • • • •
●
NEK-606 (2009), IEC 60092-350, 353, 354, 376
0.6/1kV(1.8/3kV) RFOU(VFD) Capacitance C
Inductance L
Reactance X 50 Hz
Reactance X 60 Hz
Impedance Z at 50 Hz 90℃
Impedance Z at 60 Hz 90℃
No.
mm2
㎌/km
mH / km
Ω/km
Ω/km
Ω/km
Ω/km
3C 3E 3C 3E 3C 3E 3C 3E 3C 3E
95 16 120 25 150 25 185 35 240 50
0.582
0.255
0.080
0.096
0.264
0.269
0.667
0.249
0.078
0.094
0.213
0.219
0.715
0.244
0.077
0.092
0.181
0.188
0.736
0.238
0.075
0.090
0.151
0.159
0.794
0.233
0.073
0.088
0.125
0.134
LV Power & Lighting Cable
Nominal Area
HV Power Cable
Multi core cable No. of Cores
0.6/1kV(1.8/3kV) BFOU(VFD) Capacitance C
Inductance L
Reactance X 50 Hz
Reactance X 60 Hz
Impedance Z at 50 Hz 90℃
Impedance Z at 60 Hz 90℃
No.
mm2
㎌/km
mH / km
Ω/km
Ω/km
Ω/km
Ω/km
3C 3E 3C 3E 3C 3E 3C 3E 3C 3E
95 16 120 25 150 25 185 35 240 50
0.550
0.262
0.082
0.099
0.264
0.270
0.603
0.255
0.080
0.096
0.214
0.220
0.658
0.250
0.079
0.094
0.182
0.189
0.715
0.244
0.077
0.092
0.152
0.160
0.770
0.238
0.075
0.090
0.126
0.135
Earthing & Bonding wire
Nominal Area
Instrumentation & Communication Cable
Multi core cable No. of Cores
0.6/1kV RFOU, 0.6/1kV RFCU, 0.6/1kV RFBU
㎌/km
1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300
0.199 0.237 0.282 0.326 0.401 0.490 0.509 0.588 0.591 0.705 0.713 0.813 0.793 0.799 0.832 0.857
Reactance X 50 Hz
Reactance X 60 Hz
mH / km
Ω/km
Ω/km
0.171 0.159 0.148 0.138 0.128 0.119 0.113 0.107 0.104 0.099 0.096 0.093 0.092 0.091 0.089 0.090
0.206 0.191 0.177 0.166 0.154 0.143 0.136 0.129 0.125 0.119 0.116 0.111 0.110 0.109 0.106 0.108
0.546 0.506 0.471 0.441 0.409 0.379 0.360 0.342 0.332 0.315 0.307 0.296 0.293 0.289 0.282 0.286
Multi core cable Impedance Impedance Capacitance Z Z C at 50 Hz 90℃ at 60 Hz 90℃
Inductance L
Reactance X 50 Hz
Reactance X 60 Hz
Impedance Impedance Z Z at 50 Hz 90℃ at 60 Hz 90℃
Ω/km
Ω/km
㎌/km
mH / km
Ω/km
Ω/km
Ω/km
Ω/km
15.557 9.641 5.995 3.968 2.350 1.484 0.943 0.683 0.509 0.358 0.269 0.219 0.188 0.160 0.134 0.122
15.558 9.642 5.996 3.969 2.351 1.486 0.946 0.687 0.514 0.364 0.276 0.228 0.197 0.171 0.147 0.136
0.305 0.345 0.379 0.435 0.477 0.500 0.589 0.685 0.705 0.715 0.770 0.834 0.834 0.834 0.848 0.848
0.356 0.329 0.307 0.291 0.272 0.257 0.254 0.245 0.245 0.236 0.235 0.230 0.231 0.232 0.230 0.230
0.112 0.103 0.096 0.091 0.085 0.081 0.080 0.077 0.077 0.074 0.074 0.072 0.072 0.073 0.072 0.072
0.134 0.124 0.116 0.110 0.102 0.097 0.096 0.092 0.092 0.089 0.089 0.087 0.087 0.088 0.087 0.087
15.557 9.640 5.994 3.967 2.348 1.481 0.939 0.679 0.504 0.352 0.262 0.211 0.179 0.150 0.124 0.109
15.557 9641 5.994 3.967 2.348 1.482 0.941 0.681 0.507 0.356 0.266 0.216 0.185 0.158 0.133 0.119
VFD Cable
mm2
Inductance L
Technical Information
Single core cable * ) Nominal Capacitance Area C
* Reactance for 1-conductor cables given at Three-foil formation
Offshore Cable
75
Halogen free & Mud resistant Offshore cable
Technical Information 0.6/1kV BFOU, 0.6/1kV BFCU, 0.6/1kV BFBU Single core cable * ) Nominal Capacitance Area C mm2
㎌/km
1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300
0.172 0.203 0.239 0.276 0.336 0.436 0.461 0.531 0.542 0.644 0.660 0.749 0.738 0.749 0.784 0.811
Inductance L
Reactance X 50 Hz
Reactance X 60 Hz
mH / km
Ω/km
Ω/km
0.175 0.162 0.151 0.142 0.131 0.121 0.115 0.109 0.106 0.101 0.098 0.094 0.093 0.092 0.089 0.090
0.210 0.195 0.181 0.171 0.157 0.146 0.138 0.131 0.127 0.121 0.117 0.113 0.112 0.110 0.107 0.108
0.556 0.516 0.480 0.453 0.417 0.387 0.367 0.348 0.337 0.320 0.311 0.301 0.296 0.291 0.284 0.288
Multi core cable Impedance Impedance Capacitance Z Z C at 50 Hz 90℃ at 60 Hz 90℃ Ω/km
Ω/km
15.557 9.641 5.995 3.968 2.350 1.484 0.943 0.683 0.510 0.359 0.269 0.220 0.188 0.160 0.135 0.122
15.558 9.642 5.996 3.969 2.351 1.486 0.946 0.687 0.515 0.365 0.277 0.228 0.198 0.171 0.147 0.136
㎌/km
0.278 0.309 0.345 0.385 0.435 0.500 0.527 0.556 0.589 0.695 0.715 0.758 0.758 0.782 0.807 0.820
Inductance L
Reactance X 50 Hz
Reactance X 60 Hz
mH / km
Ω/km
Ω/km
0.382 0.353 0.328 0.309 0.288 0.271 0.265 0.255 0.253 0.243 0.242 0.237 0.236 0.235 0.233 0.232
0.120 0.111 0.103 0.097 0.090 0.085 0.083 0.080 0.080 0.076 0.076 0.074 0.074 0.074 0.073 0.073
0.144 0.133 0.124 0.117 0.108 0.102 0.100 0.096 0.096 0.092 0.091 0.089 0.089 0.089 0.088 0.087
Inductance L
Reactance X 50 Hz
Reactance X 60 Hz
mH / km
Ω/km
Ω/km
0.112 0.103 0.096 0.091 0.085 0.081 0.080 0.077 0.077 0.074 0.074 0.072 0.072 0.073 0.072 0.072
0.134 0.124 0.116 0.110 0.102 0.097 0.096 0.092 0.092 0.089 0.089 0.087 0.087 0.088 0.087 0.087
Impedance Impedance Z Z at 50 Hz 90℃ at 60 Hz 90℃ Ω/km
Ω/km
15.557 9.640 5.994 3.967 2.348 1.482 0.940 0.679 0.505 0.353 0.262 0.212 0.180 0.151 0.125 0.110
15.557 9641 5.994 3.967 2.349 1.483 0.941 0.681 0.508 0.356 0.267 0.217 0.186 0.158 0.134 0.120
* Reactance for 1-conductor cables given at Three-foil formation
0.6/1kV RU Single core cable * ) Nominal Capacitance Area C mm2
㎌/km
1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300
0.199 0.237 0.282 0.326 0.401 0.490 0.509 0.588 0.591 0.705 0.713 0.813 0.793 0.799 0.832 0.857
Inductance L
Reactance X 50 Hz
Reactance X 60 Hz
mH / km
Ω/km
Ω/km
0.142 0.131 0.121 0.114 0.105 0.099 0.095 0.092 0.091 0.086 0.085 0.083 0.083 0.083 0.081 0.081
0.170 0.157 0.146 0.137 0.126 0.119 0.114 0.110 0.109 0.103 0.102 0.100 0.099 0.099 0.098 0.097
0.451 0.417 0.387 0.363 0.334 0.316 0.303 0.292 0.288 0.274 0.271 0.264 0.264 0.263 0.259 0.258
* Reactance for 1-conductor cables given at Three-foil formation
76
Offshore Cable
Multi core cable Impedance Impedance Capacitance Z Z C at 50 Hz 90℃ at 60 Hz 90℃ Ω/km
Ω/km
15.557 9.641 5.994 3.967 2.349 1.482 0.941 0.681 0.507 0.355 0.265 0.215 0.183 0.155 0.130 0.115
15.557 9.641 5.995 3.968 2.350 1.484 0.943 0.683 0.510 0.359 0.271 0.222 0.192 0.165 0.141 0.127
㎌/km
0.305 0.345 0.379 0.435 0.477 0.500 0.589 0.685 0.705 0.715 0.770 0.834 0.834 0.834 0.848 0.848
0.356 0.329 0.307 0.291 0.272 0.257 0.254 0.245 0.245 0.236 0.235 0.230 0.231 0.232 0.230 0.230
Impedance Impedance Z Z at 50 Hz 90℃ at 60 Hz 90℃ Ω/km
Ω/km
15.557 9.640 5.994 3.967 2.348 1.481 0.939 0.679 0.504 0.352 0.262 0.211 0.179 0.150 0.124 0.109
15.557 9.641 5.994 3.967 2.348 1.482 0.941 0.681 0.507 0.356 0.266 0.216 0.185 0.158 0.133 0.119
Technical Information
• • • • •
●
NEK-606 (2009), IEC 60092-350, 353, 354, 376
0.6/1kV BU
㎌/km
Reactance X 50 Hz
Reactance X 60 Hz
mH / km
Ω/km
Ω/km
Impedance Impedance Capacitance Z Z C at 50 Hz 90℃ at 60 Hz 90℃ Ω/km
1.5 0.172 0.468 0.147 0.176 15.557 2.5 0.203 0.432 0.136 0.163 9.641 4 0.239 0.401 0.126 0.151 5.994 6 0.276 0.376 0.118 0.142 3.967 10 0.336 0.351 0.110 0.132 2.349 16 0.436 0.326 0.102 0.123 1.483 25 0.461 0.315 0.099 0.119 0.941 35 0.531 0.300 0.094 0.113 0.681 50 0.542 0.295 0.093 0.111 0.507 70 0.644 0.283 0.089 0.107 0.356 95 0.660 0.276 0.087 0.104 0.266 120 0.749 0.270 0.085 0.102 0.216 150 0.738 0.268 0.084 0.101 0.184 185 0.749 0.266 0.083 0.100 0.156 240 0.784 0.261 0.082 0.098 0.130 CABLE TYPE : 0.6/1kV(1.8/3kV) BFOU(VFD) 300 0.811 0.260 0.082 0.098 0.116
Inductance L
Reactance X 50 Hz
Reactance X 60 Hz
Impedance Impedance Z Z at 50 Hz 90℃ at 60 Hz 90℃
Ω/km
㎌/km
mH / km
Ω/km
Ω/km
Ω/km
Ω/km
15.557 9.641 5.995 3.968 2.350 1.484 0.943 0.684 0.511 0.360 0.272 0.223 0.192 0.165 0.141 0.128
0.278 0.309 0.345 0.385 0.435 0.500 0.527 0.556 0.589 0.695 0.715 0.758 0.758 0.782 0.807 0.820
0.382 0.353 0.328 0.309 0.288 0.271 0.265 0.255 0.253 0.243 0.242 0.237 0.236 0.235 0.233 0.232
0.120 0.111 0.103 0.097 0.090 0.085 0.083 0.080 0.080 0.076 0.076 0.074 0.074 0.074 0.073 0.073
0.144 0.133 0.124 0.117 0.108 0.102 0.100 0.096 0.096 0.092 0.091 0.089 0.089 0.089 0.088 0.087
15.557 9.640 5.994 3.967 2.348 1.482 0.940 0.679 0.505 0.353 0.262 0.212 0.180 0.151 0.125 0.110
15.557 9.641 5.994 3.967 2.349 1.483 0.941 0.681 0.508 0.356 0.267 0.217 0.186 0.158 0.134 0.120
HV Power Cable
mm2
Multi core cable
Inductance L
LV Power & Lighting Cable
Single core cable * ) Nominal Capacitance Area C
Instrumentation & Communication Cable
* Reactance for 1-conductor cables given at Three-foil formation
Size
1.0mm2
1.5mm2
2.5mm2
Individual screen
nF/km
100
100
120
120
Collective screen
nF/km
80
80
90
90
mH/km
0.75
0.73
0.68
0.68
Inductance
VFD Cable
0.75mm2
Technical Information
Mutual capacitance
unit
Earthing & Bonding wire
250V Instrument & communication cables.
Offshore Cable
77
Halogen free & Mud resistant Offshore cable
Technical Information ELECTRICAL DATA 3. Short circuit current rating The short circuit currents quoted here are for cables operating normally at maximum conductor temperature of 90℃. HF EPR insulation is actually capable of withstanding short-term Temperature up to 250℃ According to ICEA P-32-382 Curves based on formula
Is = A x
Where Is : Short Circuit Current (kA) A : Conductor area (㎟) T1 : Operating temperature ( 90℃) T2 : Short Circuit temperature ( 250℃) t : Short Circuit duration (sec)
(T2 + 234) (T1 + 234)
0.115 log t
T1 = 90, T2 = 250 Short circuit currents (kA)
Nominal Area mm2
78
Duration of short circuit in second 0.03
0.05
0.07
0.1
0.14
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
1.5
1.3
1.0
0.8
0.7
0.6
0.5
0.4
0.3
0.3
0.3
0.3
0.2
0.2
0.2
2.5
2.0
1.6
1.3
1.1
0.9
0.8
0.6
0.6
0.5
0.5
0.4
0.4
0.4
0.3
4
3.2
2.5
2.1
1.8
1.5
1.3
1.0
0.9
0.8
0.7
0.7
0.6
0.6
0.6
6
4.9
3.8
3.2
2.7
2.3
1.9
1.5
1.3
1.2
1.1
1.0
0.9
0.9
0.8
10
8.2
6.3
5.4
4.5
3.8
3.2
2.6
2.2
2.0
1.8
1.7
1.6
1.5
1.4
16
13.0
10.1
8.5
7.1
6.0
5.0
4.1
3.6
3.2
2.9
2.7
2.5
2.4
2.2
25
20.6
15.9
13.5
11.3
9.5
8.0
6.5
5.6
5.0
4.6
4.3
4.0
3.8
3.6
35
28.5
22.1
18.7
15.6
13.2
11.1
9.0
7.8
7.0
6.4
5.9
5.5
5.2
4.9
50
38.6
29.9
25.3
21.2
17.9
15.0
12.2
10.6
9.5
8.6
8.0
7.5
7.1
6.7
70
55.9
43.3
36.6
30.6
25.9
21.6
17.7
15.3
13.7
12.5
11.6
10.8
10.2
9.7
95
77.5
60.0
50.7
42.4
35.9
30.0
24.5
21.2
19.0
17.3
16.0
15.0
14.1
13.4
120
97.9
75.8
64.1
53.6
45.3
37.9
31.0
26.8
24.0
21.9
20.3
19.0
17.9
17.0
150
120.3
93.1
78.7
65.9
55.7
46.6
38.0
32.9
29.5
26.9
24.9
23.3
22.0
20.8
185
150.8
116.8
98.8
82.6
69.8
58.4
47.7
41.3
36.9
33.7
31.2
29.2
27.5
26.1
240
198.3
153.6
129.8
108.6
91.8
76.8
62.7
54.3
48.6
44.3
41.0
38.4
36.2
34.3
300
248.7
192.6
162.8
136.2
115.1
96.3
78.6
68.1
60.9
55.6
51.5
48.2
45.4
43.1
400
329.3
255.1
215.6
180.4
152.5
127.6
104.1
90.2
80.7
73.6
68.2
63.8
60.1
57.0
500
401.0
310.6
262.5
219.6
185.6
155.3
126.8
109.8
98.2
89.7
83.0
77.7
73.2
69.5
Offshore Cable
Technical Information
• • • • •
●
NEK-606 (2009), IEC 60092-350, 353, 354, 376
4. Voltage drop
Rdc x 2L x I V
Voltage drop rate =
2) A.C. circuit Voltage drop rate of single-phase A.C.= Voltage drop rate of three-phase A.C.=
x 100(%) Rac x 2L x I V Rac x 2L x I V
x ∂ x 100(%) 3
x 2
x ∂ x 100(%)
Where L I V Rdc Rac ∂
: Cable length (km) : Current(A) : Circuit Voltage(V) : D.C. resistance at maximum rated conductor temperature (see following table) : A.C. resistance at maximum rated conductor temperature (see following table) : Inductive voltage drop coefficient
Voltage drop coefficient 3.6/6kV RFOU. 3.6/6kV RFCU, 3.6/6kV RFBU Inductive voltage drop coefficient
Nominal Area
R-dc (at 20℃)
R-dc (at 90℃)
R-ac (at 90℃)
mm2
Ω/km
Ω/km
Ω/km
100%
95%
90%
85%
80%
75%
70%
10 16 25 35 50 70 95 120 150 185 240
1.840 1.160 0.734 0.529 0.391 0.270 0.195 0.154 0.126 0.100 0.0762
2.346 1.479 0.936 0.675 0.499 0.344 0.249 0.196 0.161 0.128 0.0972
2.346 1.479 0.936 0.675 0.499 0.344 0.251 0.198 0.164 0.131 0.1010
1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
0.97 0.98 1.00 1.02 1.04 1.07 1.11 1.15 1.18 1.23 1.31
0.93 0.95 0.97 1.00 1.02 1.07 1.12 1.17 1.23 1.30 1.40
0.89 0.91 0.94 0.97 1.00 1.06 1.12 1.18 1.25 1.33 1.46
0.84 0.87 0.90 0.93 0.97 1.04 1.11 1.18 1.25 1.35 1.49
0.80 0.82 0.86 0.90 0.94 1.01 1.09 1.17 1.25 1.35 1.51
0.75 0.78 0.82 0.86 0.90 0.98 1.07 1.15 1.24 1.35 1.53
Instrumentation & Communication Cable
Dielectric power factor (at 60HZ & 90℃ Conductor temperature)
R-dc (at 90℃)
R-ac (at 90℃)
mm2
Ω/km
Ω/km
Ω/km
16 25 35 50 70 95 120 150 185 240
1.160 0.734 0.529 0.391 0.270 0.195 0.154 0.126 0.100 0.0762
1.479 0.936 0.675 0.499 0.344 0.249 0.196 0.161 0.128 0.0972
1.479 0.936 0.675 0.499 0.344 0.251 0.198 0.164 0.131 0.1010
Inductive voltage drop coefficient Dielectric power factor (at 60HZ & 90℃ Conductor temperature) 100%
1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
95%
0.99 1.00 1.02 1.04 1.08 1.12 1.16 1.19 1.25 1.32
90%
0.95 0.97 1.00 1.03 1.08 1.13 1.19 1.24 1.31 1.42
85%
0.91 0.94 0.97 1.01 1.06 1.13 1.20 1.26 1.35 1.48
80%
0.87 0.90 0.94 0.98 1.04 1.12 1.19 1.27 1.37 1.52
75%
0.83 0.86 0.90 0.95 1.02 1.10 1.19 1.26 1.38 1.54
70%
0.78 0.82 0.86 0.91 0.99 1.08 1.17 1.25 1.38 1.55
VFD Cable
R-dc (at 20℃)
Earthing & Bonding wire
6/10kV RFOU, 6/10kV RFCU, 6/10kV RFBU Nominal Area
LV Power & Lighting Cable
1) D.C. circuit
HV Power Cable
Calculate fomula
8.7/15kV RFOU, 8.7/15kV RFCU, 8.7/15kV RFBU Inductive voltage drop coefficient
Nominal Area
R-dc (at 20℃)
R-dc (at 90℃)
R-ac (at 90℃)
mm2
Ω/km
Ω/km
Ω/km
100%
95%
90%
85%
80%
75%
70%
25 35 50 70 95 120 150 185 240
0.734 0.529 0.391 0.270 0.195 0.154 0.126 0.100 0.0762
0.936 0.675 0.499 0.344 0.249 0.196 0.161 0.128 0.0972
0.936 0.675 0.499 0.344 0.251 0.198 0.164 0.131 0.1010
1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
1.01 1.02 1.05 1.08 1.12 1.17 1.20 1.26 1.34
0.98 1.00 1.03 1.08 1.14 1.20 1.25 1.33 1.44
0.94 0.97 1.01 1.07 1.14 1.21 1.28 1.37 1.50
0.91 0.94 0.98 1.05 1.13 1.21 1.29 1.39 1.54
0.87 0.91 0.95 1.03 1.12 1.21 1.29 1.40 1.57
0.83 0.87 0.92 1.00 1.10 1.19 1.28 1.40 1.58
Offshore Cable
Technical Information
Dielectric power factor (at 60HZ & 90℃ Conductor temperature)
79
Halogen free & Mud resistant Offshore cable
Technical Information ELECTRICAL DATA 0.6/1Kv(1.8/3kV) RFOU(VFD) Nominal Area
R-dc (at 20℃)
R-dc (at 90℃)
R-ac (at 90℃)
mm2 95 16 120 25 150 25 185 35 240 50
ohm/km 0.195 1.160 0.154 0.734 0.126 0.734 0.100 0.529 0.076 0.391
ohm/km 0.249 1.479 0.196 0.936 0.161 0.936 0.128 0.675 0.097 0.499
ohm/km 0.251 1.479 0.198 0.936 0.164 0.936 0.131 0.675 0.101 0.499
Inductive voltage drop coefficient Dielectric power factor (at 60Hz & 90℃ Conductor temperature) 100% 1.00
95% 1.07
90% 1.07
85% 1.05
80% 1.03
75% 1.00
70% 0.97
1.00
1.10
1.11
1.10
1.08
1.06
1.04
1.00
1.13
1.15
1.15
1.14
1.12
1.10
1.00
1.16
1.20
1.21
1.21
1.20
1.19
1.00
1.22
1.28
1.31
1.32
1.33
1.32
0.6/1kV (1.8/3kV) BFOU(VFD) Inductive voltage drop coefficient
Nominal Area
R-dc (at 20℃)
R-dc (at 90℃)
R-ac (at 90℃)
mm2
ohm/km
ohm/km
ohm/km
100%
95%
90%
85%
80%
75%
70%
95 16 120 25 150 25 185 35 240 50
0.195 1.160 0.154 0.734 0.126 0.734 0.100 0.529 0.076 0.391
0.249 1.479 0.196 0.936 0.161 0.936 0.128 0.675 0.097 0.499
0.251 1.479 0.198 0.936 0.164 0.936 0.131 0.675 0.101 0.499
1.00
1.07
1.07
1.06
1.04
1.01
0.98
1.00
1.10
1.11
1.11
1.09
1.07
1.05
1.00
1.13
1.15
1.15
1.15
1.13
1.11
1.00
1.17
1.21
1.22
1.22
1.21
1.20
1.00
1.23
1.29
1.32
1.33
1.34
1.33
Dielectric power factor (at 60Hz & 90℃ Conductor temperature)
0.6/1kV RFOU, 0.6/1kV RFCU, 0.6/1kV RFBU Inductive voltage drop coefficient
Nominal Area
R-dc (at 20℃)
R-dc (at 90℃)
R-ac (at 90℃)
mm2
ohm/km
ohm/km
ohm/km
100%
95%
90%
85%
80%
75%
70%
1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300
12.2 7.56 4.70 3.11 1.84 1.16 0734 0.529 0.391 0.270 0.195 0.154 0.126 0.100 0.0762 0.0607
15.6 9.64 5.99 3.97 2.35 1.48 0.936 0.675 0.499 0.344 0.249 0.196 0.161 0.128 0.0972 0.0774
15.6 9.64 5.99 3.97 2.35 1.48 0.936 0.675 0.499 0.344 0.251 0.198 0.164 0.131 0.1010 0.0820
1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
0.95 0.96 0.96 0.96 0.97 0.98 1.00 1.01 1.03 1.06 1.09 1.13 1.16 1.21 1.28 1.36
0.91 0.91 0.91 0.92 0.93 0.94 0.96 0.98 1.01 1.05 1.10 1.15 1.19 1.26 1.36 1.47
0.86 0.86 0.87 0.87 0.88 0.90 0.93 0.95 0.98 1.03 1.09 1.15 1.20 1.29 1.41 1.54
0.81 0.81 0.82 0.83 0.84 0.86 0.89 0.91 0.95 1.01 1.08 1.14 1.20 1.30 1.43 1.59
0.76 0.76 0.77 0.78 0.79 0.81 0.85 0.88 0.92 0.98 1.05 1.12 1.20 1.30 1.45 1.62
0.71 0.71 0.72 0.73 0.75 0.77 0.80 0.84 0.88 0.95 1.03 1.10 1.18 1.29 1.45 1.64
80
Offshore Cable
Dielectric power factor (at 60Hz & 90℃ Conductor temperature)
Technical Information
• • • • •
●
NEK-606 (2009), IEC 60092-350, 353, 354, 376
0.6/1kV BFOU, 0.6/1kV BFCU, 0.6/1kV BFBU Inductive voltage drop coefficient
Nominal Area
R-dc (at 20℃)
R-dc (at 90℃)
R-ac (at 90℃)
mm2
ohm/km
ohm/km
ohm/km
100%
95%
90%
85%
80%
75%
70%
1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300
12.2 7.56 4.70 3.11 1.84 1.16 0.734 0.529 0.391 0.270 0.195 0.154 0.126 0.100 0.0762 0.0607
15.6 9.64 5.99 3.97 2.35 1.48 0.936 0.675 0.499 0.344 0.249 0.196 0.161 0.128 0.0972 0.0774
15.6 9.64 5.99 3.97 2.35 1.48 0.936 0.675 0.499 0.344 0.251 0.198 0.164 0.131 0.1010 0.0820
1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
0.95 0.96 0.96 0.96 0.97 0.98 1.00 1.01 1.03 1.06 1.10 1.13 1.16 1.21 1.28 1.36
0.91 0.91 0.91 0.92 0.93 0.94 0.96 0.98 1.01 1.05 1.10 1.15 1.20 1.26 1.36 1.48
0.86 0.86 0.87 0.87 0.89 0.90 0.93 0.95 0.98 1.03 1.10 1.15 1.21 1.29 1.41 1.55
0.81 0.81 0.82 0.83 0.84 0.86 0.89 0.92 0.95 1.01 1.08 1.14 1.21 1.30 1.44 1.59
0.76 0.76 0.77 0.78 0.79 0.82 0.85 0.88 0.92 0.98 1.06 1.13 1.20 1.30 1.45 1.62
0.71 0.71 0.72 0.73 0.75 0.77 0.81 0.84 0.88 0.95 1.03 1.11 1.19 1.30 1.46 1.64
LV Power & Lighting Cable
HV Power Cable
Dielectric power factor (at 60Hz & 90℃ Conductor temperature)
0.6/1kV RU R-dc (at 20℃)
R-dc (at 90℃)
R-ac (at 90℃)
mm2
ohm/km
ohm/km
ohm/km
100%
95%
90%
85%
80%
75%
70%
1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300
12.2 7.56 4.70 3.11 1.84 1.16 0734 0.529 0.391 0.270 0.195 0.154 0.126 0.100 0.0762 0.0607
15.6 9.64 5.99 3.97 2.35 1.48 0.936 0.675 0.499 0.344 0.249 0.196 0.161 0.128 0.0972 0.0774
15.6 9.64 5.99 3.97 2.35 1.48 0.936 0.675 0.499 0.344 0.251 0.198 0.164 0.131 0.1010 0.0820
1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
0.95 0.96 0.96 0.96 0.97 0.98 0.99 1.00 1.02 1.04 1.08 1.11 1.14 1.19 1.25 1.32
0.90 0.91 0.91 0.92 0.92 0.94 0.95 0.97 1.00 1.03 1.08 1.12 1.16 1.23 1.32 1.42
0.86 0.86 0.86 0.87 0.88 0.89 0.91 0.94 0.96 1.01 1.06 1.11 1.17 1.25 1.36 1.48
0.81 0.81 0.81 0.82 0.83 0.85 0.87 0.90 0.93 0.98 1.04 1.10 1.16 1.25 1.38 1.51
0.76 0.76 0.77 0.77 0.79 0.80 0.83 0.86 0.89 0.95 1.02 1.08 1.15 1.25 1.39 1.54
0.71 0.71 0.72 0.72 0.74 0.76 0.79 0.82 0.86 0.91 0.99 1.06 1.13 1.24 1.39 1.55
Instrumentation & Communication Cable
Inductive voltage drop coefficient
Nominal Area
Earthing & Bonding wire
Dielectric power factor (at 60Hz & 90℃ Conductor temperature)
0.6/1kV BU Inductive voltage drop coefficient
Nominal Area
R-dc (at 20℃)
R-dc (at 90℃)
R-ac (at 90℃)
mm2
ohm/km
ohm/km
ohm/km
100%
95%
90%
85%
80%
75%
70%
1.5 2.5 4 6 10 16 25 35 50 70 95 120 50 185 240 300
12.2 7.56 4.70 3.11 1.84 1.16 0.734 0.529 0.391 0.270 0.195 0.154 0.126 0.100 0.0762 0.0607
15.6 9.64 5.99 3.97 2.35 1.48 0.936 0.675 0.499 0344 0.249 0.196 0.161 0.128 0.0972 0.0774
15.6 9.64 5.99 3.97 2.35 1.48 0.936 0.675 0.499 0.344 0.251 0.198 0.164 0.131 0.1010 0.0820
1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
0.95 0.96 0.96 0.96 0.97 0.98 0.99 1.00 1.02 1.05 1.08 1.11 1.14 1.19 1.25 1.32
0.90 0.91 0.91 0.92 0.92 0.94 0.96 0.97 1.00 1.03 1.08 1.12 1.17 1.23 1.32 1.42
0.86 0.86 0.86 0.87 0.88 0.89 0.92 0.94 0.97 1.01 1.07 1.12 1.18 1.25 1.36 1.48
0.81 0.81 0.82 0.82 0.83 0.85 0.88 0.90 0.93 0.99 1.05 1.11 1.17 1.26 1.38 1.52
0.76 0.76 0.77 0.77 0.79 0.80 0.83 0.86 0.90 0.95 1.02 1.09 1.16 1.25 1.39 1.54
0.71 0.71 0.72 0.73 0.74 0.76 0.79 0.82 0.86 0.92 1.00 1.07 1.14 1.24 1.40 1.55
Offshore Cable
Technical Information
VFD Cable
Dielectric power factor (at 60Hz & 90℃ Conductor temperature)
81
Halogen free & Mud resistant Offshore cable
Technical Information VOLTAGE RATING SELECTION Selection cable for A.C systems System voltage (kV) Supply system
3-Phase 4-Wire 3-Phase 4-Wire
3-Phase 3-Wire
3-Phase 3-Wire
2-Phase 3-Wire or 2-Phase 4-Wire
Supply category
A&B C
A&B
C
A&B
2-Phase 3-Wire or 2-Phase 4-Wire
C
1-Phase 3-Wire
A&B
1-Phase 3-Wire
C
1-Phase 2-Wire or 1-Phase 1-Wire
Note)
C
Phase to earth (Uo)
Recommended (kV)
Phase to phase (U)
Above
Up to and including
Above
Up to and including
Maximum sustained voltage (Um)
IEC standard
BS standards
UO / U
UO / U
0.15 / 0.25
-
0.15
-
0.25
0.28
0.15 / 0.25
0.15
0.6
0.25
1
1.2
0.6 / 1
0.6 / 1
-
-
-
0.15
-
0.15 / 0.25
0.15 / 0.25
-
-
0.15
0.6
-
0.6 / 1
0.6 / 1
-
0.15
-
0.25
0.28
0.15 / 0.25
0.15 / 0.25
0.15
0.6
0.25
1
1.2
0.6 / 1
0.6 / 1
0.6
1.9
-
3.3
3.6
1.8 / 3
1.9 / 3.3
1.9
3.8
3.3
6.6
7.2
3.6 / 6
3.8 / 6.6
3.8
6.35
6.6
11
12
6 / 10
6.35 / 11
6.35
8.7
11
15
17
8.7 / 15
-
8.7
12.7
15
22
24
12 / 20
12.7 / 22 0.15 / 0.25
-
-
-
0.15
-
0.15 / 0.25
-
-
0.15
0.6
-
0.6 / 1
0.6 / 1
-
-
0.6
1.9
-
1.8 / 3
1.9 / 3.3
-
-
1.9
3.3
3.6
3.6 / 6
3.8 / 6.6
-
-
3.3
6.6
7.2
6 / 10
6.35 / 11
-
-
6.6
11
12
8.7 / 15
11 / 11
-
-
11
15
17.5
12 / 20
12.7 / 22
-
0.15
-
0.21
-
0.15 / 0.25
0.15 / 0.25
0.15
0.6
-
0.84
-
0.6 / 1
0.6 / 1
-
-
-
0.15
-
0.15 / 0.25
0.15 / 0.25
-
-
0.15
0.a6
-
0.6 / 1
0.6 / 1
-
-
0.6
1.9
-
1.8 / 3
1.9 / 3.3
-
0.15
-
0.25
0.28
0.15 / 0.25
0.15 / 0.25
0.15
0.6
0.25
1
1.2
0.6 / 1
0.6 / 1 0.15 / 0.25
-
-
-
0.15
-
0.15 /0.25
-
-
0.25
0.6
-
0.6 / 1
0.6 / 1
-
-
-
0.15
-
0.15 /0.25
0.15 / 0.25
-
-
0.15
0.6
-
0.6 / 1
0.6 / 1
-
-
0.6
1.9
-
1.8 / 3
19. / 3.3
-
-
1.9
3.3
3.6
3.6 / 6
3.8 / 6.6
-
-
3.3
6.6
7.2
6 / 10
6.35 / 11
-
-
6.6
11
12
8.7 / 15
-
-
-
11
15
17.5
12 / 20
12.7 / 22
The rated voltage of the cable for a given application shall be suitable for the operating condition in the system in which the cable is used. To facilitate the choice of the cable, the system are divided into the following three categories Category A : This category comprises those systems in which any phase conductor than comes in contact with earth or an earth conductor , is automatically disconnected from the system within 1 minute. Category B : This category comprises those systems in which, under fault conditions, are operated for a short time, not exceeding 8 hours on any occasion, faults in any year should not exceed 125 hours. Category C : This category comprises all systems which do not fall into categories A and B.
82
Offshore Cable
Technical Information
• • • • •
●
NEK-606 (2009), IEC 60092-350, 353, 354, 376
3. Cold test (Bending / Impact)
4. Halogen content test
CSA C22.2 No.03 (-40℃/ -35℃)
IEC 60754-1,2 Test
5. Smoke emission test
6. Oxygen index test
IEC 61034-1,2 Test
ASTM D 2863
LV Power & Lighting Cable
IEC 60331 (at 750℃, 1000℃)
Instrumentation & Communication Cable
IEC 60332-3. CAT. A (VTFT)
Earthing & Bonding wire
2. Fire resistant test
Technical Information
VFD Cable
1. Flame retardant test
HV Power Cable
TEST METHODS & TEST EQUIPMENT
Offshore Cable
83
Halogen free & Mud resistant Offshore cable
Technical Information 7. Mud resistant test ud resistant cables shall be designed with sheathing compounds suitable for installation and operation in contact with MUD M unless otherwise specified. Type SHF Mud. The variation in the tensile strength and elongation at break values from those values obtained on the unaged sample shell not exceed 25%. The volume swell and weight increase shell not exceed 20%and 15% respectively.
1) IRM 903 requirements The variation in the tensile strength and elongation at break values from those values obtained on the unaged sample shell not exceed 30%.
2) “Drilling fluid” mud test requirements for sheathing compound SHF mud Test shall be carried out on dumbbells as specified in IEC 60092-359 Table Ⅱclause 3 except that the test fluids and conditions shall be as given in Table 1. Tesa fluid
Mineral oil type-IRM 903
Temperature
Duration
100℃
7d
Calcium Bromide Brine (Water based)
70℃
56d
Carbo Sea (oil based)
70℃
56d
8. Oil resistance All thermoset sheathed cables shall be suitable for an oil production installation. The oil resistance properties shall be demonstrated by a test according to IEC 60092-359 Table Ⅱclause 3, type SHF2.
84
Offshore Cable
Technical Information
• • • • •
●
NEK-606 (2009), IEC 60092-350, 353, 354, 376
INSTALLATION RECOMMENDATIONS HV Power Cable
The following installation recommendations are in accordance with IEC regulation and practice. Different regulations may apply in other countries.
1. Minimum cable bending radius
Type of cable
LV Power & Lighting Cable
The bending radius for the installation of cables should be not less than the values given as follows; Minimum bending radius
Unarmored or unbraided
1.8/3kV
3.6/6kV above
D ≤ 25mm
4XD
D ≺ 25mm
6XD
Metal braid screened or armored
6XD
Tape screened
8XD
Single core
12 X D
3-core
9XD
r Instrumentation & Communication Cable
Up to
D
Note) For cables rated at 3.6/6(7.2)kV and above employing flexible conductor stranding(Class5) and braid insulation shields indicating a minimum bend radius of 6D for unarmoured cables and 8D for armoured cables in concurrence with the approval of the cable manufacturer.
Earthing & Bonding wire
Notes) D : Overall diameter of cable
2. Installation temperature Minimum recommended installation temperature for cables shall be -20℃. But, if the ambient temperature were below -20℃, the cable should be installed after maintained at room temperature (about 15~25℃) for 24 hours or more.
VFD Cable
3. Pulling tension The cable pulling tension during installation can be estimated by means of the following formula: p=5kg x total cross section of conductors in the armoured cable or, p=2.5kg x total cross section of conductors in the unarmoured cable
Technical Information
Additional tension will be supplied from the braid and the insulation and sheathing compound.
Offshore Cable
85
Halogen free & Mud resistant Offshore cable
Technical Information 4. Explosion risk areas 1) Areas The areas on board are usually classified in two main categories with regards to the explosion risk : ▶Hazardous areas : Areas in which explosive gas-air mixtures are, or may be expected to be,present in quantities such as to require special precautions for the construction and use of electrical apparatus. ▶Safe areas(non-hazardous areas ) : Area in which explosive gas-air mixtures are not expected to be, present in quantities such as to required special precautions for the construction and use of electrical apparatus. A hazardous area is divided into three zones : ▶Zone 0 : in which an explosive gas-air mixture is continuously present or present for long periods. ▶Zone 1 : in which an explosive gas-air mixture is likely to occur in normal operation ▶Zone 2 : in which an explosive gas-air mixture is not likely to occur, and if occurs it will only exist for a short time
2) Installation of cables ▶For cables to be used in zone 0 and zone 1, one of the following types of protection is required: · A non-metallic outer sheath in combination with braiding or other metallic covering for earth fault detection and mechanical protection. A non-metallic outer sheath is, however, not required if the screen or armouring consists of a corrosion resistant bronze alloy. ·A lead sheathing in addition to further mechanical protection, for example armour braiding or non-metallic impervious sheath. · For mineral insulated cables, a copper or stainless steel sheath. ·Single core cables in installations with A.C or D.C. current with a high ripple content should be of types without screen of armouring. where mechanical damage is possible, such cables should otherwise be mechanically protected or installed in ducts or similar. ▶For installations in zone 2, cables without screen or armour can be used.
86
Offshore Cable
Technical Information
• • • • •
●
NEK-606 (2009), IEC 60092-350, 353, 354, 376
5. Earthing of metal coverings of cables HV Power Cable
1) General requirements All metal coverings of cables, armouring or shielding shall be earthed. Earthing must be provided at both ends except for final sub-circuits where earthing at only one end(the supply end)is sufficient. Earthing at one end is permitted where it is required for technical or safety reasons, control and instrumentation cables, mineral insulated cables, intrinsically safe circuits, control circuits etc.
LV Power & Lighting Cable
Metal covering of single core cable for AC and single core cable for DC with ripple content exceeding 10% and having a current rating exceeding 20A is to be earthed at one and only. when single core cables for AC and DC with ripple content higher than 10% are installed in or passing through hazardous areas, the metal screen or armour is to be earthed inside the hazardous area to avoid dangerous potential between screen armour and earthed part of the installation
2) Cross section of earth connections
Instrumentation & Communication Cable
Earth connections for metal coverings shall be carried out with conductors having cross sectional areas related to the cross sectional areas of the phase conductors and the current ratings of the cables, or at least the same cross sectional areas as the metal covering it self.
3) Earthing through metal clamps etc.
Earthing & Bonding wire
Metal coverings of cables may be earthed through clamps. The clamps must grip the metal covering of the cable and must be connected to the hull and provide a good conductive connection between the metal covering and the hull. The metal clamps must be corrosion resistant.
4) Earthing through cable glands
VFD Cable
The metal coverings of cables may be earthed by means of glands intended for the purpose and so designed as to ensure an effective earth connection. The glands shall be firmly attached to, and in effective electrical contact with, a metal structure earthed in accordance with these regulations.
5) Earthing of metal pipes, conduits etc.
Offshore Cable
Technical Information
Metal pipes and cable conduits are to be earthed. Pipes and conduits may be earthed by being screwed into a metal enclosure, or by nuts in both sides of the wall of metallic enclosure, provided that the surface is clean and free from rust, scale or print. Comments : For intrinsically safe circuits it is important to separate the earth conductor from the protective earthing. The resistance between a zener barrier earth and protective earth must be max. 1ohm and preferably less than. 0.1ohm to avoid that possible fault current does not lead to a potential increase in the system.
87
Halogen free & Mud resistant Offshore cable
Technical Information 6. Fixing of cables Cables are to be suitably fixed to the supports. In order to guard against the effects of electrodynamics forces developing on the occurrence of a short circuit, single core cables should be firmly fixed by using supports of a strength adequate to withstand forces corresponding to the values of prospective short circuit current. The requirement concerning fixing can normally be fulfilled when the cables are clamped as follows: • For cables entering enclosures and conduits the nearest clamp is to be placed at a minimum distance from the entry of 10 times the diameter the cable concerned from the entry. • At other points the distance between the clamps must not exceed the in the following table:
External diameter of cable (mm)
Spacing of fixing points (mm)
Above
Up to
Cables without Metal braid or armor
Cables with copper, bronze or steel braid or armor
-
8
200
250
8
13
250
300
12
20
300
350
20
30
350
400
30
-
400
450
7. Mechanical protection of cables Cables are to be installed in such a way that they are not subject to damaging mechanical stressed. where this can not be obtained the cables are to be protected. Unless the cable itself(for example armour or sheath) provides adequate protection the cables should be: • Enclosed in suitable conduits or casings • covered by steel pipes or profiles • Steel pipes in which the cables are run in areas where there is an exceptional risk of mechanical damage, for example in cargo hold area or different storage areas, the cables always have to be protected, even when the cables are armoured. The thickness of the protective conduits must be at least 4mm. The wall thickness of the protective conduit must be at least 2mm. Cables lay on aluminum supports may have a corresponding protection of aluminum. the thickness must be at least 4mm. Metal casing used for mechanical protection of cables should be efficiently protected against corrosion.
88
Offshore Cable
Technical Information
• • • • •
●
NEK-606 (2009), IEC 60092-350, 353, 354, 376
8. Installation of cables for fire properties HV Power Cable
Cables must at least meet the flame retardant requirements. On board passenger ships, cargo-ships and mobile offshore units, where requirements are considered to be satisfied if the cables have characteristics complying withe the cable bunch test IEC-Publication 60332-3, or fire stops are installed in accordance with the following recommendations:When cable complying with single-cable test, but not the cable-bunch-test, are installed, fire stops are to be provided in enclosed or semi-enclosed spaces except for cargo rooms and tunnels in cargo areas. a) For vertical cable runs
LV Power & Lighting Cable
- with a max. distance between fire stops of two decks or 6 meters, unless installed in totally enclosed cable ducts - at the main and emergency switchboard - where cables enter into an engine control room - at centralized control panels for propulsion machinery and essential auxiliaries - at the entrance to cables ducts
b) For horizontal cable runs.
- Fire stops shall be as specified in item a) above but the maximum. distance between fire stops may be increased to 14m.
Instrumentation & Communication Cable
When choosing cable types special attention should be paid to reduce possible damage due to corrosion in case of a fire. Non-halogen free cables(materials)will give off corrosive gases during a fire. The corrosion effect depends on the amount of halogens in the materials used. Flame retardant cables are to give characteristics complying with the test requirements in IEC-Publication 60332-1, with amendments. Fire resistant cables are to give characteristics complying with the requirements in IEC-Publication 60331.
9. Intrinsically safe installations
Earthing & Bonding wire
Cables and flexible cables for intrinsically safe circuits must have screen or similar of a conducting material and the outer sheath must be of an insulating material. A non-metallic outer sheath is, however, not required if the screen or armour consists of a corrosion resistant bronze alloy. Where there is no danger of interference from the external electrical or magnetic fields, short flexible cables may be used without screen. a) Associated equipment
Associated equipment(e.g.power supply units) shall be situated in a safe area or has protection as mentioned in "Explosion risk areas."
b) Connection of equipment
Within limitations laid down in 3., ordinary non-explosion protected equipment may be connected to intrinsically safe equipment, provided that it is designed to meet regulations in other respects.
c) Compliance with any limitations in the certificate
VFD Cable
With intrinsically safe circuits special considerations must be given to ensure that the circuits characteristics (including connected equipment, cables, conductors etc.) satisfy any limitations in the test certificate. Such limitations may be maximum values for capacitance and inductance etc. It is pointed out there is a danger of damage to i.s equipment when using normal equipment for insulation testing
d) Adjacent location Conductors for i.s safe circuits and conductors for non-i.s safe circuits shall not be run together in the same cable, flexible cable, conduit, cables bunch etc.
e) Protection against electrical and magnetic fields
Technical Information
Where i.s circuits are exposed to magnetic or electrical field that may destroy the intrinsic safety of the system. Precautions must be taken during installation. Such precautions may be: - cables for i.s circuits and non-i.s circuits to be installed a minimum distance of 50mm apart. The minimum distance to heavy current cables using D.C with a high ripple content should be 300mm. - cables for i.s circuits and non-i.s circuits to be separated panel of conducting material which is earthed. - cables for i.s circuits to have effective transposition.
f) Marking
The marking may be a marking plate or by colour marking of the cables when using colour marking, the colour should be light blue.
Offshore Cable
89
Halogen free & Mud resistant Offshore cable
Technical Information CORE IDENTIFICATION 1. High voltage power cables The individual cores shall be identified by the colored semi-conducting tape or colored ribbon tape run longitudinally on the non-metallic part of insulation screening and the colour scheme shall be as follows: 1 core : Off-white (Grey) 3 core : Off-white (Grey), Black, Red, or Off-white(Grey), Red, Blue
2. Low voltage power and control cables The insulated cores shall be identified by the color of insulation or by the number printed on insulated cores; as follows 1) NEK-606 standard 1core : Off-white(Grey) or Black 2core : Off-white, Black 3core : Off-white, Black, Red 4core : Off-white, Black, Red, Blue or Black, Off-white, Red, Green. 5core and above core: white number on black insulation or black number on white insulation Earth core : Green/Yellow (green base with yellow stripe) 2) CENELEC harmonization document HD 308 S2 2C
-
-
3C
Green / Yellow
Blue
Brown
4C
Green / Yellow
-
Brown
Black
5C
Green / Yellow
Blue
Brown
Black
2C
Blue
Brown
3C
-
Brown
Black
Grey
Grey
4C
Blue
Brown
Black
Grey
Grey
5C
Blue
Brown
Black
Grey
3. Instrumentation and communication cables Each pair/triad shall be identified as follows. - Pairs : Black, Light blue or Black, White - Triads : Black, Light blue, Brown or Black, White, Red For identification of multi-pair/triad cables, pair/triad are identified by lapping of the numbered tape or by the number print directly on the each cores, and the number interval shall be 100mm or less. The other color scheme may be applicable when purchaser required.
90
Offshore Cable
Black
Technical Information
• • • • •
Handling, Installation Method & Notice
●
NEK-606 (2009), IEC 60092-350, 353, 354, 376
■Loading & Transportation 1. In case of a crane Should transport by using standard rope and a shaft which is put in the center of drum.
HV Power Cable Right
Wrong
LV Power & Lighting Cable
* Matters that requires attention - Placing it even with the ground. - Should move slowly and when it placedown, don’t do sudden stop.
Shaft
2. In case of a forklift Drums should not be damaged by a forklift.
Instrumentation & Communication Cable
* Matters that requires attention: - Place the drum on the center of a fork. - The width of a fork should be longer than drum size.
✽Matters that requires attention while handling cables. • Don’t lie drums down. • Don’t move it 20m longer when rolling it. • Don’t use gimlets or something like sharp when moving. • Don’t roll a damaged drum. • Don’t roll at projecting surface. • Don’t store drum near to stove and heater.
Right
Earthing & Bonding wire
■Transportation and Unloading
Wrong
Check point while handling cables(Storage) VFD Cable
■Storage
Technical Information
• Don’t leave the protecting packing materials and outside package until remove it for setting up cables. • Should construct a fence to protect against damages by moving machines. • Keep it inside or in depository when safekeeping in long term. (For reference, drums and packages can stand against dry whether outside the house) • Must seal both sides of cables remaining in the drums the cap and heat-contracting tube so that moisture doesn’t soak in after finishing the removal of exterior packing materials and cutting and installing cables.
Offshore Cable
91
Halogen free & Mud resistant Offshore cable
Certificates Approved
Cert. of ISO 9001
Cert. of ISO 14001
Cert. of OHSAS 18001
92
Offshore Cable
BV
GOST-R
Instrumentation & Communication Cable
DNV
Earthing & Bonding wire
ABS
VFD Cable
LV Power & Lighting Cable
HV Power Cable
Class Type Approval
Technical Information
Technical Information
• • • • •
●
NEK-606 (2009), IEC 60092-350, 353, 354, 376
Offshore Cable
93
Halogen free & Mud resistant Offshore cable
Memo
94
Offshore Cable
Technical Information
VFD Cable
Earthing & Bonding wire
Instrumentation & Communication Cable
LV Power & Lighting Cable
HV Power Cable
Technical Information
• • • • •
●
NEK-606 (2009), IEC 60092-350, 353, 354, 376
Offshore Cable
95
www.tmc-cable.com Head Office / Ipjang Factory #368-7, gasan-ri, Ipjang-Myeon, Cheonan-si, Chungnam, Korea Tel. +82-41-589-6500 Fax. +82-41-589-6400 Bukmyeon Factory #330-852, Maesong-ri, Buk-Myeon, Cheonan-si, Chungnam, Korea Tel. +82-41-554-0630 Fax. +82-41-553-7166 Seoul Office #100-704,13F Danam Building, Namdaemunno 5-ga, Jung-gu, Seoul, Korea Tel. +82-2-771-3434 Fax. +82-2-771-3003 Geoje Office KHAN Building 1F, 915 Aju-dong, Geoje-si, Gyeongsangnam-do, Korea Tel. +82-55-688-5261 Fax. +82-55-688-5262 Dalian Office(China) Changjiang Office Building No.123 Changjiang Road. Zhongshan District 939/940 Room Dalian,China. Tel. +86-411-8252-9669, 9769 Fax. +86-411-8269-8316
TMC1309-1000