DM-COG12864-708   

12864 COG GRAPHIC LCD WITH 8080  OR 6800 MPU INTERFACE   

 

DM-COG12864-708 

Contents  Revision History  Main Features  Pin Description  Mechanical Drawing  Electrical Characteristics  Optical Characteristics  Block diagram  Timing Characteristics  System Bus Read/Write Characteristics (For the 8080 Series MPU)  System Bus Read/Write Characteristics (For the 6800 Series MPU)  Table of Commands  Driver/Controller Information  Reliability  Warranty and Conditions     

 

Copyright © 2015                                                           2 / 10                                             www.displaymodule.com   

 

DM-COG12864-708 

1 Revision History  Date  2015-03-13 

Changes  First release 

   

2 Main Features  Item  Resolution  Display Mode  Controller IC  Interface  Power Supply  View Direction  Duty  Backlight  Weight 

Specification  128 x 64  FSTN, Transflective  ST7565R  8080 or 6800 MPU Interface  3.3V  12:00  1/65 duty, 1/9 bias  Edge White LED   25.5 

Unit  pixel  -  -    V  -    -  g 

   

 

Copyright © 2015                                                           3 / 10                                             www.displaymodule.com   

 

DM-COG12864-708 

3 Pin Description  Pin No.  1  2  3  4  5 

Symbol  /CS  /RESET  A0  R/W  E 

6~10 

DB0~DB3 

11~13 

DB4~DB7 

14  15  16  17  18  19  20  21  22~26  27  28  29  30 

VDD  VSS  VOUT  CAP3-  CAP1+  CAP1-  CAP2-  CAP+  V1~V5  VR  C86  PS  /IRS 

Function Description  Used to enter chip select signal   Controller reset (module reset)   Register select signal  Read/write select signal  Operation (data read/write) enable signal  Four low order bi-directional three-state data bus lines.  Used for data transfer between the MPU and the LCM.  These four are not used during 4-bit operation.  Four high order bi-directional three-state data bus lines.   Used for data transfer between the MPU  Power supply for logic (+5V) for LCM  Signal ground for LCM (GND) 

DC/DC voltage converter. 

A multi-level power supply for the liquid crystal drive.   Output voltage regulator terminal.  This is the MPU interface switch terminal.  This is the parallel input/serial data input switch terminal.  This terminal selects the resistors for the V5 voltage level adjustment. 

  

Copyright © 2015                                                           4 / 10                                             www.displaymodule.com   

 

DM-COG12864-708 

4 Mechanical Drawing 

 

Copyright © 2015                                                           5 / 10                                             www.displaymodule.com   

 

DM-COG12864-708 

5 Electrical Characteristics 

 

Item  Supply Voltage For Logic  Digital Operation Current  Low Level Input Voltage  High Level Input Voltage  Low Level Output Voltage  High Level Output Voltage  Backlight Forward Voltage  Backlight Forward Current  Operating Temperature  Storage Temperature 

Symbol  VDD  IDD  VIL  VIH  VOL  VOH  VLED  ILED  TOP  TST 

Condition    -              Absolute Max  Absolute Max 

Min  3.0  -  0  2.2  -  2.4      -20  -30 

Typ.  3.3  0.35  -  -      6.0  30     

Max  3.5  0.45  0.6  VDD  0.4  -      70  80 

Max  35  40  500     

Unit  °  °  us    cd/m² 

Unit  V  mA  V  V  V  V  V  mA  ℃  ℃ 

6 Optical Characteristics  Item  View Angle-Top -- Bottom  View Angle-Left -- Right  Response Time (25°C)  Contrast Ratio  Luminance 

 

Symbol  AV  AH  Tr + Tf  CR  LV 

Min  -25  -40       

Typ      300  6   

 

7 Block diagram 

   

Copyright © 2015                                                           6 / 10                                             www.displaymodule.com   

 

DM-COG12864-708 

8 Timing Characteristics  8.1 System Bus Read/Write Characteristics (For the 8080 Series MPU) 

  VDD=4.5V to 5.5V, Ta=25C  

 

Symbol  tAH8  tAW8  tCYC8  tCCLW  tCCLR  tCCHW  tCCHR  tDS8  tDH8  tACC8  tOH8 

Item  Address hold time  Address setup time  System cycle time  Control Low pulse width (/WR)  Control Low pulse width (/RD)  Control High pulse width (/WR)  Control High pulse width (/RD)  Data setup time  Address hold time  /RD access time  Output disable time 

Min  0  0  166  30  70  30  30  30  10  -  5 

Typ  Max  Unit  -  -  ns      ns  -  -  ns  -  -  ns  -  -  ns  -  -  ns  -  -  ns    -  ns    -  ns    70  ns    50  ns  VDD=2.7V to 4.5V, Ta=25C  

Symbol  tAH8  tAW8  tCYC8  tCCLW  tCCLR  tCCHW  tCCHR  tDS8  tDH8  tACC8  tOH8 

Item  Address hold time  Address setup time  System cycle time  Control Low pulse width (/WR)  Control Low pulse width (/RD)  Control High pulse width (/WR)  Control High pulse width (/RD)  Data setup time  Address hold time  /RD access time  Output disable time 

Min  0  0  300  60  120  60  60  40  15  -  10 

Typ  -    -  -  -  -  -         

Max  -    -  -  -  -  -  -  -  140  100 

Unit  ns  ns  ns  ns  ns  ns  ns  ns  ns  ns  ns 

Copyright © 2015                                                           7 / 10                                             www.displaymodule.com   

 

DM-COG12864-708 

8.2 System Bus Read/Write Characteristics (For the 6800 Series MPU) 

  VDD=4.5V to 5.5V, Ta=25C  

 

Symbol  tAH6  tAW6  tCYC6  tEWLW  tEWHW  tEWLR  tEWHR  tDS6  tDH6  tACC6  tOH6 

Item  Address hold time  Address setup time  System cycle time  Enable Low pulse width (WRITE)  Enable High pulse width (WRITE)  Enable Low pulse width (READ)  Enable High pulse width (READ)  WRITE Data setup time  WRITE Address hold time  READ Access time  READ Output disable time 

Min  0  0  166  30  30  30  70  30  10  -  10 

Typ  -    -  -  -  -  -         

Max  -    -  -  -  -  -  -  -  70  50 

Unit  ns  ns  ns  ns  ns  ns  ns  ns  ns  ns  ns 

VDD=2.7V to 4.5V, Ta=25C  

 

Symbol  tAH6  tAW6  tCYC6  tEWLW  tEWHW  tEWLR  tEWHR  tDS6  tDH6  tACC6  tOH6 

Item  Address hold time  Address setup time  System cycle time  Enable Low pulse width (WRITE)  Enable High pulse width (WRITE)  Enable Low pulse width (READ)  Enable High pulse width (READ)  WRITE Data setup time  WRITE Address hold time  READ Access time  READ Output disable time 

Min  0  0  300  60  60  60  120  40  15  -  10 

Typ  -    -  -  -  -  -         

Max  -    -  -  -  -  -  -  -  140  100 

Unit  ns  ns  ns  ns  ns  ns  ns  ns  ns  ns  ns 

Copyright © 2015                                                           8 / 10                                             www.displaymodule.com   

 

DM-COG12864-708 

9 Table of Commands 

   

10 Driver/Controller Information  Built-in ST7565R Controller  https://drive.google.com/file/d/0Bxu0OURUiyL5TUVKSnlURXRUbFE/view?usp=sharing   

Copyright © 2015                                                           9 / 10                                             www.displaymodule.com   

 

DM-COG12864-708 

11 Reliability  Test Item  High Temperature  Storage  Low Temperature  Storage  High Temperature  Operation 

Low Temperature  Operation  High Temperature/  Humidity Operation 

Thermal Shock  Resistance 

Content of Test  Endurance test applying the high  storage temperature for a long time.  Endurance test applying the high  storage temperature for a long time.  Endurance test applying the electric  stress (Voltage & Current) and the  thermal stress to the element for a long  time.  Endurance test applying the electric  stress under low temperature for a long  time.  The module should be allowed to stand  at 60℃,90%RH max, for 96hrs under  no-load condition excluding the  polarizer. Then taking it out and drying it  at normal temperature.  The sample should be allowed stand the  following 10 cycles of operation 

Test Condition  80℃  200hrs  -30℃  200hrs  70℃  200hrs 

-20 ℃  200hrs 

Note  2  1,2 





60℃,90%RH  96hrs  1,2 

-20℃/70℃  10 cycles  - 

Vibration Test 

Static Electricity Test 

  Endurance test applying the vibration  during transportation and using 

Endurance test apply the electric stress  to the terminal. 

Total fixed  amplitude:  15mm;  Vibration:  10~55Hz;   One cycle 60  seconds to 3  directions of X,  Y, Z, for each 16  minutes.  VS=800V,   RS=1.5kΩ,  CS=100pF,  1 time. 





Note1:  No dew condensation to be observed.  Note2:  The function test shall be conducted after 4 hours storage at the normal. Temperature and  humidity after remove from the rest chamber.  Note3:  Test performed on product itself, not inside a container. 

12  Warranty and Conditions  http://www.displaymodule.com/pages/faq 

Copyright © 2015                                                           10 / 10                                             www.displaymodule.com   

 

DM-COG12864-708-Datasheet.pdf