Don’t Be Fooled by Voltage Reference Long-Term Drift and Hysteresis – Design Note 229 John Wright

Lies About Long-Term Drift Some manufacturers are now touting phenomenal long-term drift specifications, based on accelerated high temperature testing. THIS IS A DELIBERATE LIE! Long-term drift cannot be extrapolated from accelerated high temperature testing. The only way long-term drift can be determined is to measure it over the time interval of interest. The erroneous technique produces numbers that are wildly optimistic and uses the Arrhenius Equation to derive an acceleration factor from elevated temperature readings. The equation is: AF = e

EA ⎛ 1 1 ⎞ ⎜ – ⎟ K ⎝ T1 T2⎠

where: E A = Activation Energy (Assume 0.7) K = Boltzmann’s Constant T2 = Test Condition in °Kelvin T1 = Use Condition Temperature in °Kelvin

Equation the acceleration factor is 767 and the projected “bogus” long-term drift is 0.156ppm/1000hr at 30°C. For a 2.5V reference, this corresponds to a 0.39μV shift after 1000 hours. This is pretty hard to determine (read impossible) if the peak-to-peak output noise is larger than this number. As a practical matter, one of the best laboratory references available has long-term drift of 1.5μV/mo. This performance is only available from the best subsurface zener references such as the LTZ1000, utilizing specialized heating techniques. Competitive Reference Measures 500 Times Worse Than Claimed Long-term drift data was taken with parts that were soldered onto PC boards similar to a “real world” application. These boards were not preconditioned. They were placed into a constant temperature oven with TA = 30°C and their outputs were scanned regularly and measured with an 8.5 digit DVM. Figures 1 and 2 show typical long-term drift of the LT1461S8-2.5 and the SOT-23 LT1790S6-2.5. Initially, data was taken every hour where the largest changes occur, but after several hundred hours the frequency was lowered to reduce the large number of data points. Figure 3 shows long-term 200 150 DRIFT (ppm)

The new micropower LT®1461 and LT1790 low dropout bandgap voltage references excel not only in temperature coefficient and accuracy, but also in longterm drift and hysteresis (output voltage shift due to temperature cycling). Long-term drift and hysteresis, which are sometimes ignored or wrongly specified by other manufacturers, can be the accuracy limitations of systems. System calibrations can remove TC and initial accuracy errors, but only frequent calibration can remove the long-term drift and hysteresis. Subsurface Zener references, like the LT1236, have the best longterm drift and hysteresis, but they do not offer low output voltage options, low supply current and low operating supplies like these new bandgap references.

100 50 0 –50 0

200 400 600 800 1000 1200 1400 1600 DN229 F01 HOURS

Figure 1. LT1461S8-2.5V Long-Term Drift 200

L, LT, LTC, LTM, Linear Technology and the Linear logo are registered trademarks of Linear Technology Corporation. All other trademarks are the property of their respective owners. 04/00/229_conv

DRIFT (ppm)

150

To show how absurd this technique is, compare this calculation to real LT1461 data. Typical 1000 hour long-term drift at 30°C = 60ppm. The typical 1000 hour long-term drift at 130°C is 120ppm. From the Arrhenius

100 50 0 –50

0

200 400 600 800 1000 1200 1400 1600 DN229 F02 HOURS

Figure 2. LT1790SOT23-2.5V Long-Term Drift

200

DRIFT (ppm)

150 100 50 0 –50

0

200 400 600 800 1000 1200 1400 1600 DN229 F03 HOURS

85°C, 25°C and –40°C and all 25°C output voltages were recorded. The stabilization time at each temperature was 30 minutes. The worst-case output voltage changes at 25°C are shown in Figures 4 and 5 for the LT1461S8-2.5 and the SOT-23 LT1790S6-2.5. A competitive reference, which makes no mention of hysteresis on its data sheet, was also measured and is shown in Figure 6.

Figure 3. XXX291S8-2.5V Long-Term Drift

Hysteresis Limits Repeatability When a reference is soldered onto a PC board, the elevated temperature and subsequent cooling cause stress that influences the output. If the voltage reference is repeatedly temperature cycled, inelastic stress is applied to the chip and the output voltage does not return to the 25°C initial value. The mechanical stress is due to the difference in thermal coefficients of expansion between the silicon chip, plastic package and PC board. This error, known as “thermally induced hysteresis,” is expressed in ppm and cannot be trimmed out because it is variable and has memory of previous temperature excursions. Hysteresis is always worse with higher temperature excursions, and differs with die attach and package type. Hysteresis—Often the “Missing” Spec Most manufacturers ignore hysteresis specifications, but they can be critical in precision designs. To graphically show hysteresis, many references were IR reflow soldered onto PC boards and the boards underwent a “heat soak” at 85°C (this ensures that they all had the same initializing temperature). The temperature was then cycled multiple times between Data Sheet Download

www.linear.com

Linear Technology Corporation

PERCENTAGE OF UNITS

60 85°C TO 25°C

– 40°C TO 25°C

50 40 30 20 10 0 –200

–160

–120

–80

–40 0 40 DISTRIBUTION (ppm)

80

120

160

200 DN229 F04

Figure 4. LT1461S8-2.5 Industrial Hysteresis 50 PERCENTAGE OF UNITS

Long-term drift can be reduced by preconditioning the PC board after the reference has been soldered onto the board. Operating the PC board at 25°C or elevated temperature stabilizes initial drifts. This “burn-in” of the PC board eliminates the output shift that occurs in the first several hundred hours of operation. Further changes in output voltage are typically logarithmic and changes after 1000 hours tend to be smaller than before that time. Because of this decreasing characteristic, long-term drift is specified in ppm/√kHr.

70

40 30 85°C TO 25°C

– 40°C TO 25°C

20 10 0 –200

–160

–120

–80

–40 0 40 DISTRIBUTION (ppm)

80

120

160

200 DN229 F05

Figure 5. LT1790S6-2.5 Industrial Hysteresis 50 PERCENTAGE OF UNITS

drift of a competitive reference that specifies long-term drift of 0.2ppm/kHr in its data sheet. Measured data shows this reference to have drift between 60ppm/ kHr and 150ppm/kHr or 300 to 750 times worse than claimed.

80

40 30 – 40°C TO 25°C

85°C TO 25°C 20 10 0 –200

–160

–120

–80

–40 0 40 DISTRIBUTION (ppm)

80

120

160

200 DN229 F06

Figure 6. XX780S8-2.5 Industrial Hysteresis

Conclusion Voltage references from Linear Technology are conservatively and accurately specified, unlike those from other manufacturers that intentionally mislead or eliminate key specifications to cover shortcomings—shortcomings that may cause large errors. The new LT1461 and LT1790 excel in all specifications that set system precision. There is nothing left out and there is nothing hidden.

For applications help, call (408) 432-1900 dn229f_conv LT/TP 0400 370K • PRINTED IN THE USA

1630 McCarthy Blvd., Milpitas, CA 95035-7417 (408) 432-1900



FAX: (408) 434-0507 ● www.linear.com

© LINEAR TECHNOLOGY CORPORATION 2000

Don't Be Fooled by Voltage Reference Long ... - Linear Technology

Long-term drift cannot be extrapolated from accelerated high temperature testing. The only way long-term drift can be determined is to measure it over the time ...

96KB Sizes 3 Downloads 190 Views

Recommend Documents

DN351 - Versatile Micropower Voltage Reference ... - Linear Technology
age divider programs the buffer op amp to provide gain. Figure 2 shows ... This configuration provides program- mable reference ... The LT6650 often finds use in single supply data acqui- ... that software algorithms can accurately “auto-zero”.

Robust High Voltage Over-The-Top Op Amps ... - Linear Technology
Design Note 533. Glen Brisebois .... considerations necessary when designing robustness into high ... the industrial system designer a precision solution for high ...

Robust High Voltage Over-The-Top Op Amps ... - Linear Technology
drive the output stage. As the ... Over-The-Top Input Stage on LT6015 Can Common Mode to 76V, Independent of Positive Supply Voltage. Q12. NPN ... the FET can turn hard on. This is ... down to 0.2V. Circuit gain is recovered in the second.

High Voltage Inverting Charge Pump Produces ... - Linear Technology
optimized, allowing maximum available output power with only a few millivolts peak-to-peak output ripple. Light load efficiency can be increased by reducing the.

Wide Input Voltage Range Boost/Inverting/SEPIC ... - Linear Technology
of Linear Technology Corporation. All other trademarks are the property ... lithium-ion powered systems to automotive, industrial and telecommunications power ...

High Voltage, Low Noise, DC/DC Converters - Linear Technology
Application Note 118. AN118-4 an118fb. Low Noise Switching Regulator Driven Resonant. Royer Converters. Figure 8 examplifies the aforementioned “special ...

Bootstrap Biasing of High Input Voltage Step ... - Linear Technology
Introduction. High voltage buck DC/DC controllers such as the LTC3890. (dual output) and LTC3891 (single output) are popular in automotive applications due ...

DN561 High Voltage, High Efficiency Positive to ... - Linear Technology
The –12V Output Converter (U1) Provides 5A to the Load in the Input Voltage ... ment tools, testing systems, LED drivers and battery ... For applications help,.

High Voltage, Low Noise, DC/DC Converters - Linear Technology
can provide surprisingly good performance, particularly at low output current. ...... minimal ripple current may not create a significant field, but such an inductor ...

Dont Be Sad.pdf
There was a problem previewing this document. Retrying... Download. Connect more apps... Try one of the apps below to open or edit this item. Dont Be Sad.pdf.

DN568 Reference Filter Increases 32-Bit ADC ... - Linear Technology
While reference noise has no effect at zero-scale, at full-scale any noise on the reference will be visible in the output code. This is why dynamic range ... voltage, produces a maximum error of 6µV which is relatively insignificant compared to the

DN514 - A Robust 10MHz Reference Clock Input ... - Linear Technology
of Linear Technology Corporation. All other trademarks are the ... RF instruments and wireless transceivers often feature an input for an external reference clock, ...

LTC1560-1 - Linear Technology
Gain vs Frequency of the 1MHz and 500kHz. Figure 1. A Typical ... 6. 5. GND. VIN. GND. V–. VOUT. SHDN. V+. 0.5fC/fC. 5V. 3. 1k. 2. 4. VOUT. 7. LT®1360. 5V. – 5V. 8 ... DC offset of the 1/2 LT1364 plus its offset current times the 10k resistor ..

DN172 - Linear Technology
response is excellent, with less than 5μs recovery time from a ±400mA ... Data Sheet Download ... LTC1504 is the best solution where efficiency, especially.

DN518 - Linear Technology
possible to produce a low noise supply in this way, it requires careful ... typical switching regulator, and (3) the LTM8028 low ... call (408) 432-1900, Ext. 3747.

DN375 - Linear Technology
call (408) 432-1900. RF FREQUENCY (GHz) ... For ACPR/AltCPR, center the measurement band 5MHz/10MHz above the center of the highest carrier. To find ...

DN531 - Linear Technology
SiR664DP. M2. SiR664DP. L1. 5.6µH. WÜRTH 7443556560. M3. SiR422DP. M5. SiR422DP. D6. B360A. C19. 0.22µF. 25V. 0603. C20. 0.22µF. 25V. 0603. C21.

eterna1 - Linear Technology
Dec 16, 2015 - ... If testing encompasses measuring ETERNA1's output power or PSD, ..... go to: http://csrc.nist.gov/groups/STM/cavp/documents/aes/aesval.html.