GD100 GD100 – Single Channel Detector The GD100 is a cost‐effective, single‐channel, din‐rail mounted, microprocessor‐based detector used to detect vehicle presence by means of an inductance change caused by the vehicle passing over a wire loop buried under the road surface. With front panel switches to allow for different loop frequency settings, sensitivity settings and mode settings, the GD100 is a compact, low‐voltage detector specifically designed for the Gate & Door market.
Applications
Parking barrier control.
Safety loop.
Arming control.
Motorised gates and doors.
Industrial control systems.
Specific Features
Compact Size: This compact industry‐standard housing combines all the requirements regarding features and functionality and allows this detector to be incorporated into any new or existing vehicle detection system.
Selectable Fail‐Safe/ Fail Secure: Allows a selectable output for either Fail Safe or Fail Secure operation.
Loop Isolation Protection: The loop isolation transformer provides protection against lightning and transient damage and allows for operation with single point to ground sensor loops.
Loop Frequency Indication: The possibility of cross‐talk (interference) between adjacent loops/ detectors can be determined by a visual display, and eliminated by changing the frequency settings. Automatic Sensitivity Boost (ASB): Facilitates the reliable detection of all vehicle combinations and high‐ bed vehicles by boosting the sensitivity to maximum after detection of a vehicle.
Typical Application
Muntaner 262, 4º, 1ª ‐ 08021 Barcelona ℡ +34 932 022 924 ‐ Fax: +34 932 020 090
[email protected] www.quadrex.es
GD100 Technical Data Self‐tuning Range:
20 – 1500 µH
Sensitivity:
Four step adjustable on faceplate High 0.02% L/L Med‐High 0.05% L/L Med‐Low 0.1% L/L Low 0.5% L/L
Frequency:
Two step adjustable on faceplate 12‐80kHz (Frequency determined by loop geometry)
Output Configuration:
Pulse Output Duration:
2 output relays Relay 1=Presence Output Relay 2=Pulse on Detect Output Approx. 150 ms
Presence Time:
1 hour for 3%
Operating Modes:
Mode Selector on faceplate: 1. Fail‐Safe/ Fail‐Secure
Indications:
The following faceplate indications are provided: Red LED – power Green LED ‐ channel indicator 1. Tuning‐on steady, followed by flashed frequency count (x10kHz) 2. Undetect – off 3. Detect – on steady 4. Fault – on with short off periods
Protection:
Loop isolation transformer RFI filtering, zener diode clamping on loop inputs and gas discharge tube protection. 24V AC/DC±10% Requirements – 1.5 VA max
Power Requirements: Output Relays:
L/L or Permanent presence option
Operating Temperature Range:
Presence Relay ‐ 1A @ 230V AC, Change over contacts Pulse Relay ‐ 1A @ 230V AC, Change‐over contacts (non fail‐safe) ‐40°C to +80°C (Circuit sealed against condensation)
Material:
High Heat ABS Blend
Dimensions:
79mm (L) 22.5mm (W) 99mm (H)
Mounting:
Din Rail Mount
Connector:
Dual front 3 way screw terminal on faceplate and 2 way plugable screw terminal.
Muntaner 262, 4º, 1ª ‐ 08021 Barcelona ℡ +34 932 022 924 ‐ Fax: +34 932 020 090
[email protected] www.quadrex.es