Standard GM250T5, GM250T5N, GM250T5NG, GM250T5G 250 Amp System, 415 Volts GM250T5

GM250T5NG

128 mm

128 mm

108 mm

GM250T5NG shown 250 Amp System, 415 Volt (OVERSIZED NEUTRAL & ISOLATED PROTECTIVE EARTH)

End Cap page 4.7

108 mm

Page 4.1 | www.StarlinePower.com

Power Feed page 4.5-4.6

Housing Coupler page 5.8

Tee Page 4.4



Housing Section page 4.2 Bus Connector page 4.8

Support Hardware page 4.7

Elbow page 4.3

Installation Tool page 4.8

Accessories – Closure Strip 4.7

Plug-In Units page 7.7-7.10

 CHASSIS EARTH

T5

Uses aluminium housing as 100% rated earth path, and no extra copper bar. GM100 GM225

DEDICATED EARTH

T5G

Extra bar in busway for earth. Everything tied together inside plugs. Chassis and dedicated earth bar at same potential. GM100G

ISOLATED EARTH

T5G

6hr receptacles position in plugs. Chassis earth isolated from copper earth bar. Isolated earth carried back to panel by others. GM100G

Protective Earth Options

l

www.StarlinePower.com

FAQ CHASSIS EARTH, DEDICATED EARTH, ISOLATED EARTH

Page 4.1b



(L2)

GM250T5NG shown

128mm (L1) (N)

(L3)

108mm

HOUSING SECTIONS

Spring pressure

(PE)

Tool Force

GM250T5NG-4PG-3-415

GM250T5N-4PG-6-415

GM250T5N-4PG-3-415

GM250T5G-4PG-6-415

GM250T5G-4PG-3-415

GM250T5-4PG-6-415

GM250T5-4PG-3-415

Catalog No.

250A, 4P/ISO PE/200%N

250A, 4P/200%N

250A, 4P/200%N

250A, 4P/Iso PE

250A, 4P/Iso PE

250A, 4-pole

250A, 4-pole

Description

6m

3m

6m

3m

6m

3m

6m

3m

Length

46.2 kg

23.1 kg

42.6 kg

21.3 kg

41.7 kg

20.8 kg

37 kg

18.5 kg

Weight

www.uecorp.com

250A, 4P/ISO PE/200%N l

GM250T5NG-4PG-6-415

Housing sections are joined by inserting the Bus Connector which fits into the channels of the adjoining section. The installation tool is then rotated to force blades into slots.

“Spring-pressure” channel busbar US Pat. # 6,039,584

Spring pressure

GM250T5, GM250T5N, GM250T5G, GM250T5NG Systems Track Busway housing sections consist of an extruded Aluminium shell with “spring-pressure” type copper channel busbars contained in a full length halogen-free insulator mounted on the interior walls. The Aluminium extrusion acts as a 100% protective earth meeting IEC 60439-2. Each housing has a continuous access slot over its entire length for the insertion of turn-n-lock plug-in units. The plug-in opening features finger safety to IP2X. Housing configurations include 3  or 4-pole varieties 220…415V, optional isolated protective earth, and optional oversize (200%) neutral. The housing sections join together using Bus Connectors which fit into the channels of the adjoining section. An Installation Tool is used to force the blades into the busbar channels for a solid “spring-pressure” electrical connection. MATERIAL: Extruded Aluminium RATINGS: 100% Protective Earth 250 Amps GM250T5/GM250T5G 415 Volt GM250T5N/GM250T5NG 415 Volt LENGTH: 3 m OR 6 m VOLTAGE DROP: Distributed load, .8PF Single Phase 14.9 m per Volt Three Phase 17.6 m per Volt



Catalog Number Sequence GM250T5–(X)PG–(L) Length 3 or 6 Metres or custom length

No. of Poles System size = 250 Amps G - Isolated PE NG - ISO PE & 200% Neutral

Page 5.2

Page 4.2 | www.StarlinePower.com

Elbow Section

-R Version Shown

Top View Shown

Polarizing Stripe

GMEL250T5-4-L Internal Elbow

GMEL250T5N-4-L

GMEL250T5G-4-R

GMEL250T5G-4-L

GMEL250T5-4-R

GMEL250T5-4-L

Catalog No.

Elbow, 4-pole/ISO PE/200%N, left

Elbow, 4-pole/200%N, right

Elbow, 4-pole/200%N, left

Elbow, 4-pole/ISO PE, right

Elbow, 4-pole/ISO PE, left

Elbow, 4-pole, right

Elbow, 4-pole, left

Description

6.6 kg

6.4 kg

6.4 kg

6.1 kg

6.1 kg

5.9 kg

Elbow shown with Joint Kits installed

GMEL250T5N-4-R

6.6 kg

5.9 kg

GMEL250T5NG-4-L

Elbow, 4-pole/ISO PE/200%N, right

Weight

GMEL250T5NG-4-R

GMEL250T5-4-R External Elbow

Horizontal Elbow

ELBOW SECTION

GM250T5, GM250T5N, GM250T5G, GM250T5NG Systems

An Elbow is used for making a horizontal 90 degree change of direction in a Busway run. Specify right or left elbow according to the orientation of the polarizing stripe in the Busway sections to be connected. Plug-in unit cannot be inserted in elbow section open channel.

(Ordered Separately)

CONNECTION ACCESSORIES:

Joint Kit (GMJK250T5 series) is used to make mechanical and electrical connections to adjacent Busway sections.

Catalog Number Sequence GMEL250T5-(P)–(X) Direction (Right, Left) Number of Poles System size = 250 Amps G – Isolated PE NG – ISO PE & 200% Neutral

Elbow

Page 4.3 | www.StarlinePower.com

Elbow Section

Internal Right -IR

TEE SECTION

Internal Left -IL

Tee, 4-pole, Internal Left

Description

External Left -EL

Catalog No.

8.9 kg

External Right -ER

GMT250T5-4-IL

Tee, 4-pole, External Left

8.9 kg

Polarizing Stripe

GMT250T5-4-EL

Tee, 4-pole, Internal Right

8.9 kg

8.9 kg

GMT250T5-4-IR

Tee, 4-pole, External Right

Weight

GMT250T5-4-ER

Top View Shown

GM250T5, GM250T5N, GM250T5G, GM250T5NG Systems

A Tee is used for making a horizontal 90 degree branch leg in a Busway run. Specify either internal or external, and either right or left tee according to the orientation of the polarizing stripe in the Busway sections to be connected. Plug-in unit cannot be inserted in tee section open channel.

CONNECTION ACCESSORIES: (Ordered Separately) A Joint Kit (GMJK250T5 series) is used to make mechanical and electrical connections to adjacent Busway sections.

Catalog Number Sequence

System size = 250 Amps G – Isolated PE NG – ISO PE & 200% Neutral

No. of Poles

Direction External or Internal Right or Left

GMT250T5-(P)-(XX)

Tee

Page 4.4 | www.StarlinePower.com

Catalog No. GMEF250T5-4-415 GMEF250T5-4R-415 GMEF250T5G-4-415 GMEF250T5G-4R-415 GMEF250T5N-4-415 GMEF250T5N-4R-415 GMEF250T5NG-4-415 GMEF250T5NG-4R-415

As shown on layout dwg

Standard

Reversed

Description End Feed, 4-Pole End Feed, 4-Pole/Rev End Feed, 4-Pole/Iso PE End Feed, 4-Pole/Iso PE/Rev End Feed, 4-Pole/200% N End Feed, 4-Pole/200% N/Rev End Feed, 4-Pole/ISO PE/200% N End Feed, 4-Pole/ISO PE/200% N/Rev

Weight 8.0 kg 8.0 kg 8.2 kg 8.2 kg 8.6 kg 8.6 kg 8.9 kg 8.9 kg

Assembled with 305mm 3 of Busway

Supplying Power to End of Busway

END POWER FEED UNITS

GM250T5, GM250T5N, GM250T5G, GM250T5NG Systems

End Power Feed Units Standard End Power Feed units connect to the end of any busway section. Factory assembled unit consists of a 305 X 406 X 165mm steel junction box with removable sides connected to a 305mm section of busway. The assembly includes connection lugs for wires up to 152mm2. Chassis earth isolated earth allow wires up to 67mm2 and 42mm2 respectively. Reverse End feed units for connection to opposite end of busway section (polarizing stripe faces to right as viewed from junction box end of unit). End Power Feed units are connected to adjacent Busway sections using Housing Coupler and Bus Connector which are sold separately. (Joint Kit – T5 Series) Special need Power Feed units for confined spaces as might be found in Mission Critical Data Centers can also be designed and fabricated, requiring minimum quantities. Reference page 5.1b for dedicated ground application. Contact UEC representative for further information.

Reverse

Catalog Number Sequence GMEF250T5–(P)(R) System Poles System size = 250 Amps G – Isolated PE NG-ISO PE & 200% Neutral DG – Dedicated Earth End Feed

Page 4.5 | www.StarlinePower.com

Standard

Hinged side

(R) Reversed

Description Top Feed, 4-Pole Top Feed, 4-Pole/Rev Top Feed, 4-Pole/ISO PE Top Feed, 4-Pole/ISO PE/Rev Top Feed, 4-Pole/200% N Top Feed, 4-Pole/200% N/Rev Top Feed, 4-Pole/ISO PE/200% N Top Feed, 4-Pole/ISO PE/200% N/Rev

Hinged side

Catalog No. GMTF250T5-4-415 GMTF250T5-4R-415 GMTF250T5G-4-415 GMTF250T5G-4R-415 GMTF250T5N-4-415 GMTF250T5N-4R-415 GMTF250T5NG-4-415 GMTF250T5NG-4R-415

Weight 19.1 kg 19.1 kg 19.8 kg 19.8 kg 20.0 kg 20.0 kg 20.7 kg 20.7 kg

Busway Section

Supplying Power to TOP of Busway

TOP POWER FEED

GM250T5, GM250T5N, GM250T5G, GM250T5NG Systems

Top Power Feed Units Standard Top Power Feed units supply power from the topside of the Busway. Factory assembled unit consists of a 508 X 305 X 203 mm steel junction box, with hinged cover, mounted on top of a 914mm section of Busway.

Top Feed Power units can be positioned at end or anywhere along a busway run. Connections to adjoining busway sections are made by the standard means, requiring housing couplers and bus connectors which are sold separately. (Joint Kit – T5 Series)

Catalog Number Sequence GMTF250T5–(P) System Poles System size = 250Amps G– Isolated PE NG– ISO PE & 200% Neutral Top Feed

Page 4.6 | www.StarlinePower.com

END CAP

WEIGHT 0.67 kg/m. 0.44 kg/m.

PART NUMBER GMCST5-AL GMCST5-1

WEIGHT 0.5 kg.

PART NUMBER GMBRHT5-1 GMBHT5-1

WEIGHT 0.2 kg

PART NUMBER GMEC250T5

GMBHT5-1

GMBRHT5-1

CONNECTION ACCESSORIES

GM250T5, GM250T5N, GM250T5G, GM250T5NG Systems

For covering the end of GM250T5 Busway run.

HANGER BOLTS Threaded Rod (GMBRHT5-1) For mounting to M12 threaded rod. Twist-in design. Can be inserted anywhere along the full access slot on the top of the Busway. Maximum hanger support spacing is every 3m.

Standard (GMBHT5-1) For mounting to strut or other flat surfaces. Twist-in design. Can be inserted anywhere along the full access slot on the top of the Busway. Maximum hanger support spacing is every 3m.

ALUMINIUM /PVC CLOSURE STRIP Affixes with an adhesive backing to access slot of GM250T5 housing sections. Normally shipped in 3m lengths.

Page 4.7 | www.StarlinePower.com

PART NUMBER GMJK250T5-1 GMJK250T5G-1 GMJK250T5N-1 GMJK250T5NG-1 WEIGHT 1.8 kg

Weight 1.4 kg

229mm

Busway Section

INSTALLATION TOOL

Tool Pressure

Busway section

JOINT KIT/INSTALLATION TOOL

GM250T5, GM250T5N, GM250T5G, GM250T5NG Systems GM250 JOINT KIT For connection of adjacent Busway sections. One Kit required at each joint. Each Kit is comprised of a housing coupler pair and bus connector set. Specify configuration to match busway configuration.

HOUSING COUPLER: Consists of two, 12-screw couplers – one for the top of the housing and one for the bottom. Housing Couplers are polarized with a stripe corresponding to the polarization of the housing.

BUS CONNECTOR: Copper blades secured to insulating mounting plate. Left and Right set, makes electrical connection between sections.

INSTALLATION TOOL: Used to install bus connector between two adjacent sections of Busway. Busway sections are butted together and the top housing coupler is installed. The Bus connector is inserted, centered, and seated in the slot of the Busway joint. The installation tool is inserted into jointed intersection and rotated 90º forcing stabs into female conductors making a ‘springpressure’, secure electrical connection. Bottom housing coupler is then centered and installed.

Part Number GMT5IT

For Standard T5 Series Installation Tool

Page 4.8 | www.StarlinePower.com

GM Busway Guide 250T5G.pdf

Power Feed page. 4.5-4.6. Housing Section. page 4.2. Installation Tool. page 4.8. Support Hardware. page 4.7. End Cap page. 4.7. Tee. Page 4.4. Housing. Coupler page. 5.8. Elbow page. 4.3. Plug-In Units page. 7.7-7.10. Bus Connector. page 4.8. GM250T5NG shown. 250 Amp System, 415 Volt. (OVERSIZED NEUTRAL ...

877KB Sizes 1 Downloads 220 Views

Recommend Documents

GM Mustard.pdf
Whoops! There was a problem loading this page. Retrying... Whoops! There was a problem loading this page. Retrying... Whoops! There was a problem previewing this document. Retrying... Download. Connect more apps... Try one of the apps below to open o

GM breweries.pdf
Leverage = 1.7x. Radico Khaitan IMIL < 5%. United Breweries. United Spirits. Tilak Nagar industries. PEERS in CL. Picadaly Agro. Leverage = 2.2x. D/E = 1.2x.

é%gm%
Corresponrierta In: T. Tsuji ( Tel:-+2-ll-S24-24-7692. Fax:+Sl-S24-22-'Fl9.'i. E—ma.il [email protected]) properties. Flash (1987) performed computer ...

GM Reference.pdf
Draw an additional card in a procedural scene. • Call the next scene ... GM Spends Up Cards Down Cards PvP Spends ... Page 1 of 1. GM Reference.pdf.

pdf-1831\el-monte-busway-cost-effectiveness-considerations-by ...
... more apps... Try one of the apps below to open or edit this item. pdf-1831\el-monte-busway-cost-effectiveness-considerations-by-michael-p-gallagher.pdf.

DS GM Shield.pdf
Page 1 of 4. Page 1 of 4. Page 2 of 4. Page 2 of 4. Page 3 of 4. Page 3 of 4. Page 4 of 4. Page 4 of 4. DS GM Shield.pdf. DS GM Shield.pdf. Open. Extract.

GM FY17 Proposed Budget Details.pdf
100-100-30-54483-000.000 EPSDT-TRSU Pass Thru 0.00 5,818.77 0.00 0.00. 100-100-30-55400-114.000 Misc Revenue-Surplus/Def 135,000.00 0.00 100,000.00 100,135.00. 100-100-30-55481-000.000 Medicaid Grant Revenue 30,000.00 74,307.34 30,000.00 45,000.00. 1

GM Bluetooth Guide.pdf
Page 1 of 5. General Information. □ GM vehicles equipped with a Bluetooth system can use a Bluetooth-capable cell phone with a Hands. Free Profile to make ...

GM viết bài.PDF
Thai gian clang 1(1T tham 15/10/2016. • Du kien died gian to chirc: ... There was a problem loading this page. GM viết bài.PDF. GM viết bài.PDF. Open. Extract.

STD-12 GM CHAP_06.pdf
Sign in. Page. 1. /. 11. Loading… Page 1 of 11. Page 1 of 11. Page 2 of 11. Page 2 of 11. Page 3 of 11. Page 3 of 11. STD-12 GM CHAP_06.pdf. STD-12 GM ...

STD-12 GM CHAP_07.pdf
Whoops! There was a problem previewing this document. Retrying... Download. Connect more apps... STD-12 GM CHAP_07.pdf. STD-12 GM CHAP_07.pdf.

Nagpur & Pune Metro GM Recruitment [email protected] ...
Nagpur & Pune Metro GM Recruitment [email protected]. Nagpur & Pune Metro GM Recruitment [email protected]. Open. Extract. Open with. Sign In.

GM Meeting Agenda 03.29.16.pdf
“France is in Europe.” – Yurguen's TA. ○ Call Meeting ... Open Forum. o Come to office hours Friday ... GM Meeting Agenda 03.29.16.pdf. GM Meeting Agenda ...

GM-180 Day Reading Plan.pdf
Sign in. Page. 1. /. 1. Loading… Page 1 of 1. HOKIE STONE. Jl. Tubagus Angke Raya, Komp. Angke Megah. Blok B No. 26 , Jakarta Barat 11460. Telp : 021 - 29332827(H). Email : [email protected]. I. Ahli Waris / Wakil / Pemohon : Yang bertanda

GM-180 Day Reading Plan.pdf
... 6 ❏ Hebrews 12 ❏ Revelation 20. 29 ❏ Mark 10 ❏ Romans 3 - 4 ❏ Philippians 1 - 2 ❏ Hebrews 13 ❏ Revelation 21. 30 ❏ Mark 11 ❏ Romans 5 - 6 ❏ Philippians 3 - 4 ❏ James 1 ❏ Revelation 22. 31 ❏ Mark 12 ❏ Romans 7 - 8 ❏ J

2017 Visitor Home GM Time 2017 Visitor Home GM Time
Tue. Dec. 5 th. Osborne. Vickers. R. Wing (6). J. Dief. 3:55. 3:55. Tue. Dec. 5th. Osborne. Wild Rose. Red Wing. A. Pechey (2). J. Dief. Birch Hills. Shellbrook. Vickers (1). Vickers (2). King George. 3:55. 3:55 .... To request a city official, conta

STD-10 GM CHAP_04.pdf
Sign in. Page. 1. /. 26. Loading… Page 1 of 26. Page 1 of 26. Page 2 of 26. Page 2 of 26. Page 3 of 26. Page 3 of 26. STD-10 GM CHAP_04.pdf. STD-10 GM ...

STD-12 GM CHAP_10.pdf
Sign in. Page. 1. /. 17. Loading… Page 1 of 17. Page 1 of 17. Page 2 of 17. Page 2 of 17. Page 3 of 17. Page 3 of 17. STD-12 GM CHAP_10.pdf. STD-12 GM ...

STD-10 GM CHAP_11.pdf
STD-10 GM CHAP_11.pdf. STD-10 GM CHAP_11.pdf. Open. Extract. Open with. Sign In. Main menu. Displaying STD-10 GM CHAP_11.pdf. Page 1 of 23.