BITMAIN

AntMiner S4+ Manual

AntMiner Manual Last updated: 4/22/2015 Page 2 of 9

Contents 1 2 3 4

5 6

Overview ................................................................................................................................... 3 Features..................................................................................................................................... 3 Connect to Miner ...................................................................................................................... 3 Miner Configuration .................................................................................................................. 6 4.1 Pool Setting ................................................................................................................... 6 4.2 Frequency Modification ................................................................................................ 6 Miner Status .............................................................................................................................. 7 System Configuration and status............................................................................................... 7 6.1 System Upgrading ......................................................................................................... 7 6.2 Password Modification .................................................................................................. 8 6.3 Software Version Checking............................................................................................ 9 6.4 Restore Initial Setting .................................................................................................... 9

Page 2 / 9

AntMiner Manual Last updated: 4/22/2015 Page 3 of 9

1 Overview Bitmain is introducing the newest miner: the AntMiner S4+. More powerful and efficient than its predecessor, the S4+ packs quite a punch. It uses the state of the art BM1382 chip powered by ultra-low power 28nm technology, with 2570Gh/s hash rate. S4+ will be shipped out with built-in PSU and it’s tested and configured prior to shipping to make it easier for customers to set up.

Please note: 1. The included PSU cannot be used in countries with a mains power voltage lower than 205V. The PSU will not start below this voltage. 2. Power line is not included, please find one with at least 10A in your local market.

2 Features Ideal Hash Rate (GH/s)

2570

Default chip clock (M)

200

Estimate power on wall (W)

1480

Estimate efficiency on wall (J/GH)

0.58

Dimensions (mm)

432 x 442 x 133

Weight (kg)

14.4

3 Connect to Miner Step 1. The default DHCP network protocol distributes IP addresses automatically. Please download IPReporter.zip from minerlink.com, then please follow below steps to find out the IP of Page 3 / 9

AntMiner Manual Last updated: 4/22/2015 Page 4 of 9

the miner. Note: when finding the IP address, the PC and miner should be connected to the same router via Ethernet wire. 1. Extract the file and double click ‘IPReporter.exe’. The ‘Shelf, Step, Position’ options are suitable for farm miners to mark the location of the miners. For home miners, it can be left as default. Then click ‘Start’.

2. Press the raised IP Reporter button on right top corner of panel, next to the green and red LED light, you’ll hear a beep sound:

3. Check your PC, you’ll see the IP address showing in the pop-up window.

Page 4 / 9

AntMiner Manual Last updated: 4/22/2015 Page 5 of 9

Step 2. Enter the IP address provided into your WEB browser and proceed to login using ‘root’ for both the username and password. In the ‘Network’ section, you can assign a ‘Static’ IP address if you like. Click ‘Save&Apply’ after modifying it.

Page 5 / 9

AntMiner Manual Last updated: 4/22/2015 Page 6 of 9

4 Miner Configuration 4.1 Pool Setting You can configure your miner through ‘Miner Configuration->General Settings‘. Pool URL- Enter the URL of your desired pool in this column. Worker- This is your worker ID on the selected pool. Password- This is the password for your selected worker. Comment: 4.1.1 The AntMiner S4+ can be set up with three mining pools, with decreasing priority from the first pool (pool 1) to the third pool (pool 3). The pools with low priority will only be used if all higher priority pools have gone offline. 4.1.2 When ‘Stop running when temperature is over 95℃’ is checked, the miner will stop mining when the temperature exceeds 95℃ to protect the miner. If it’s unchecked, the miner will still mine even in high temperature. Click ‘Save & Apply’ to save and restart miner.

4.2 Frequency Modification You are able to modify the frequency value through ‘Miner Configuration->Advanced Settings‘. The default frequency for the AntMiner S4+ is 200M.

Page 6 / 9

AntMiner Manual Last updated: 4/22/2015 Page 7 of 9

5 Miner Status You can check the operating status of your miner on ‘Miner Status’ page. ASIC#: Number of chips detected in the chain Frequency: ASIC frequency setting Temp: Temperature, centigrade ASIC status: o stands for OK, x stands for error.

6 System Configuration and status 6.1 System Upgrading You can upgrade he miner’s firmware on ‘System->Upgrade’ page.

Page 7 / 9

AntMiner Manual Last updated: 4/22/2015 Page 8 of 9

‘Keep setting’ is chosen by default and should be enabled if you want to keep your current settings. You should deselect this option if you are trying to return the miner to default settings. Click ‘Browse’ button to choose upgrade file. Select the upgrade and click the ’Flash image...’ button. The interface will display if the firmware can be upgraded and download the software. During the upgrade process, you need to wait patiently, and must keep power on, otherwise, the AntMiner can only be fixed with returned to factory. You will see below screenshot after upgrading successfully.

Clicking the ‘Reboot’ button will restart the miner so it can load the new software. Clicking ‘Go Back’ will keep the AntMiner mining, before switching to the new software when it is restarted next time or power cycled.

6.2 Password Modification The AntMiner login password can be changed on the ‘System->Administration’ page. Once modified, press ‘Save&Apply’ to save the new password.

Page 8 / 9

AntMiner Manual Last updated: 4/22/2015 Page 9 of 9

6.3 Software Version Checking You can check which version of the software you are currently running on the ‘System->Overview’ page. ‘File System version’ displays the date of the firmware your miner use. In the example below, the miner is using 20150402 firmware.

6.4 Restore Initial Setting There is a ‘Reset’ button on the left hand side of the IP Reporter button, press and hold the button for 5 seconds in order to restore to the default settings and reboot. The red LED will flash once every 15 seconds automatically if the reset is operated successfully.

Page 9 / 9

AntMiner-S4+ user guide.pdf

There was a problem previewing this document. Retrying... Download. Connect more apps... Try one of the apps below to open or edit this item. AntMiner-S4+ ...

1MB Sizes 8 Downloads 152 Views

Recommend Documents

User Authenticator Authenticator Specific Modules FIDO Client User ...
Generate UAuth Key Pair = (Auth.pub, Auth.priv) for this handle h = (a, u) by ak. 2. Generate the Key Registration Data = KRD = (AAID, h, Auth.pub, fc, Att.cert, reg − cntr, cntr, sig = signature by Att.priv(AAID, Auth.pub, fc, Att.pub, reg − cnt

A Tradeoff Between Single-User and Multi-User ... - Semantic Scholar
which shows good performance at the high interference region. [22]. Taking the merits ... nas respectively, each STA can transmit a data stream with an. Alamouti ...

User Logged in successfully by Database? User ... -
Return remap GUID to. Identity column from database as CAS ID. User Logged in successfully by Database? User Logged in. Successfully by LDAP. Remap GUID to database CAS. ID.. Is CAS ID found? Create new record in database matching GUID. Success. RETU

User Privacy o User Privacy on Social Networking ...
As users are enjoying this new style of networking, privacy concerns are also attracting increasing public attention due to reports about privacy breaches on social networking sites. A significant amount of work for privacy protection on OSN(Online S

Tenable.io User Guide
2 days ago - See the Search documentation for more information about contextual ...... UDP is a stateless protocol, meaning that communication is not per- formed with ...... In addition, make sure you enforce a policy that man- dates the use ...

User Manual - GitHub
Page 1. User Manual. Project Odin. Kyle Erwin. Joshua Cilliers. Jason van Hattum. Dimpho Mahoko. Keegan Ferrett. Page 2. Contents. Contents. Section1 .

GWR4.09 User Manual - GitHub
Starting the program, Exiting the program, and Tab design ...................... 5 ..... GWR4 runs on Windows Vista, Windows 7, 8 and 10 environments with the .

User Manual - EEVblog
written notice of any defect prior to the end of the applicable warranty period. ATL's obligation ... ATL's systems contain ATL's proprietary software in machine—readable form. This ..... To display pre-defined or custom (user-defined) annotation.

Semantic user interface
Oct 26, 2001 - 707/2, 3*6, 100, 101, 103 R, 104.1, 202, .... le.edu/homes/freeman/lifestreams.html, pp. .... pany/index.html, last visited Apr. 26, 1999, 2 pages.

User Guide - Loyalty Wireless
Multi-tasking is easy with Android because open applications keep running ...... Magic Remote is compatible only with LG Smart TVs released in 2012 and after. 1 Select ..... Allows you to receive multimedia content from LG phones or tablets.

User Guide - Loyalty Wireless
Multi-tasking is easy with Android because open applications keep running even when you open another application. There is no need to quit an application ...

USER Roles.pdf
Page 1 of 6. help.edublogs.org http://help.edublogs.org/what-are-the-different-roles-of-users/. User Role Overview. When you set up a blog you have the ability ...

user guide - GitHub
TOOLS AnD EVA ITEMS CAn BE FOUnD In A nEW TAB UnDER SCIEnCE CATEGORy. .... But THE greatest thing above all is KSP community. ... Of course, we still need hard work to improve our mods and we have many other ideas as.

User Manual - EEVblog
ATL's systems contain ATL's proprietary software in machine—readable form. This ..... To display pre-defined or custom (user-defined) annotation with the Text A ...

SPSToolbox - User Manual - GitHub
May 15, 2013 - Contents. 1 Introduction .... booktitle = {Proceedings of the Automation and Applied Computer Science Workshop ..... System Sciences Series.

user cooperation diversity for multi-user ccma
node to node communication by using additional relay nodes. e.g.[4],[5]. The paper by Sendonaris et.al [6] has considered user cooperation in multiuser communications and particularly for CDMA. In this paper, we propose a cooperative scheme for achie

Tenable.io User Guide
Create a connector to import asset records from third-party applications. 2. Filter the ...... Click Plugin Family to enable (green) or disable (gray) the entire family.

OCEMR: User Manual - GitHub
In order to access the program, OCEMR, find the Firefox tab located to the left of the screen. .... click on the view option next to the patient record with the most ..... entered, the report will appear as a download at the bottom of the popup scree

The User Manual - GitHub
Defined Wireless Networking Experiments 2017 ..... 1.7.3 Encryption. Mininet-WiFi supports all the common wireless security protocols, such as WEP (Wired Equivalent. Privacy), WPA (Wi-Fi Protected Access) and WPA2. ..... mac80211_hwsim practical exam

User Manual.pdf
84-341-RisingHF Temperature and Humidity Sensor RHF1S001 EU868- User Manual.pdf. 84-341-RisingHF Temperature and Humidity Sensor RHF1S001 ...

Inventory User Guide
Dec 4, 2000 - This form allows the user to associate any Person with any of the following 'object types': Obj_Type_Nam e. Obj_Type_Dscr. Software. A role with the Software objects. Computer. A physical computing facility capable of independent use fo

VFS User Manual - GitHub
wind turbines considering the non-linear effects of the free surface with a two-phase .... the nodes of the computational domain are classified depending on their location with ...... bcs.dat need to be set to any non-defined value such as 100.

Camera User Guide
System Map . ... Locking the Flash Exposure Setting (FE Lock) . . . . . . . . . . . 96. Adjusting the .... Using an Externally Mounted Flash (Sold Separately) . . . . 203.