Terluran GP-35 Product Data Sheet

Acrylonitrile/Butadiene/Styrene

09/99 TL GP-35

ABS

Terluran GP-35 acrylonitrile/butadiene/styrene copolymer (ABS) is a very high flow injection molding grade with good resistance to impact and heat deflection. It is intended for a wide range of applications, particularly in thin-walled components for telecommunications, consumer products, business equipment and automotive.

Method

Units

Terluran GP-35 ABS

Density

ASTM D1505

g/cm3

1.04

Melt Volume Rate (Melt Flow Index) 200°C/5kg (cond. G) 220°C/10kg 230°C/3.8kg (cond. I)

ASTM D1238

ml/10 min. (g/10 min.)

Tensile Strength at Yield, Type 1, 0.125”

ASTM D638

psi (MPa)

6,500 (45)

Elongation at Yield

ASTM D638

%

2.4

Tensile Strength at Break, Type 1, 0.125”

ASTM D638

psi (MPa)

4,800 (33)

Tensile Modulus, 0.125”

ASTM D638

psi (MPa)

360,000 (2,500)

Flexural Strength, 0.125”

ASTM D790

psi (MPa)

9,400 (65)

Flexural Modulus

ASTM D790

psi (MPa)

340,000 (2,350)

Rockwell Hardness

ASTM D785

R

102

Notched Izod Impact Strength, 0.125” 73°F (23°C) 0°F (-18°C) -22°F (-30°C)

ASTM D256

ft.lbs./in. (J/m)

Heat Deflection Temperature at 264 psi, 0.250" annealed 8hrs. at 85°C unannealed

ASTM D648

°F (°C)

206 (97) 167 (75)

Heat Deflection Temperature at 66 psi, 0.250" annealed 8hrs. at 85°C unannealed

ASTM D648

°F (°C)

214 (101) 192 (89)

Vicat Softening Temperature, Rate A, Loading 2

ASTM D1525

°F (°C)

203 (95)

UL 94



HB

Property Description

Flammability Rating1, 0.059" (1.5 mm) thick sample 1

3.1 (3.0) 35.0 (34.3) 10.0 (9.8)

4.5 (240) 1.6 (85) 1.5 (80)

Flammability ratings are not intended to reflect hazards presented by these materials under actual fire conditions.

Values shown are based on limited testing of unmodified, uncolored material (unless otherwise noted) and are not intended to be used in establishing maximum or minimum ranges for specification purposes.

Plastics and Fibers

Terluran® GP-35 ABS

BASF Performance Plastics

Processing

Products

Drying Terluran GP-35 ABS will attract moisture from the atmosphere, with the rate depending on temperature and humidity. It is recommended that the material be dried in a dehumidifying dryer at 170°F to 175°F (75°C - 80°C) for 2 - 4 hours. Recycling A maximum of 20% reprocessed material can be added to the virgin product provided that it has not been contaminated or previously degraded. The reprocessed material must be dried to prevent any addition of moisture to the virgin material before processing.

BASF Plastic Materials offers a broad range of performance plastics from which users can select an optimum material to meet their requirements. These materials include several types of Ultramid polyamides (PA6, 66, 6/66, 6/6T), Ultraform acetal copolymer (POM), Ultradur polybutylene terephthalates, Luran styrene/ acrylonitrile, Luran S acrylonitrile/styrene/acrylate (ASA) and ASA/polycarbonate blends (ASA/PC), Terluran acrylonitrile/ butadiene/styrene (ABS), Terlux methylmethacrylate/ acrylonitrile/ butadiene/styrene (MABS), Ultrason E polyethersulfone (PES), and Ultrason S polysulfone (PSU).

Processing Temperatures Injection Molding: Melt temperatures for Terluran GP-35 ABS lie between 430°F and 500°F (221°C - 260°C) with mold temperatures between 85°F and 140°F (30°C - 60°C).

Important: While the descriptions, designs, data and information contained herein are presented in good faith and believed to be accurate, it is provided for your guidance only. Because many factors may affect processing or application/use, we recommend that you make tests to determine the suitability of a product for your particular purpose prior to use. NO WARRANTIES OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE MADE REGARDING PRODUCTS DESCRIBED OR DESIGNS, DATA OR INFORMATION SET FORTH, OR THAT THE PRODUCTS, DESIGNS, DATA OR INFORMATION MAY BE USED WITHOUT INFRINGING THE INTELLECTUAL PROPERTY RIGHTS OF OTHERS. IN NO CASE SHALL THE DESCRIPTIONS, INFORMATION, DATA OR DESIGNS PROVIDED BE CONSIDERED A PART OF OUR TERMS AND CONDITIONS OF SALE. Further, you expressly understand and agree that the descriptions, designs, data and information furnished by BASF hereunder are provided gratis and BASF assumes no obligation or liability for the description, designs, data and information given or results obtained, all such being given and accepted at your risk.

Processing Precautions Avoid excessive melt temperatures and long residence times as this could lead to thermal degradation.

Luran, Terluran, Ultradur, Ultraform, Ultramid, and Ultrason are registered trademarks of BASF AG. Terlux is a registered trademark of BASF Corporation.

For Technical Assistance please call: 1-800-527-TECH (1-800-527-8324) or 1-734-324-5150 if calling from outside the U.S.

BASF Corporation Plastic Materials 3000 Continental Drive - North Mount Olive, New Jersey 07828-1234 Tel: 800-BC-RESIN Fax: 973-426-3912

BASF Corporation Plastics Applications Center 1609 Biddle Avenue Wyandotte, Michigan 48192 Tel: 734-324-5105 Fax: 734-324-6858

BASF Canada 345 Carlingview Drive Toronto, Ontario M9W 6N9 Canada Tel: 416- 675-3611 Fax: 416-674-2588

BASF Mexicana S.A. de C.V. Insurgentes Sur 975 Col. Ciudad de los Deportes Delegación Benito Juarez 03710 México, D.F. México Tel: 011-52-5-325-2624 Fax: 011-52-5-611-6751

Not all applications permit the use of regrind. Those applications which do allow the use of regrind should be tested for the appropriate mechanical properties per the specific molded part and application.

© 1999 BASF Corporation

World Wide Web: http://www.basf.com/plastics BASF SMART FAX Automated telephone request system to deliver datasheets to you via fax. Dial the phone number below and follow the voice commands. Request document no. 1 for complete listing. 800-TOP-FAX1 (734-283-8373 outside the U.S.)

Plastics and Fibers

FT. TERLURAN GP 35 - BASF.pdf

GP-35 ABS will attract moisture from the. atmosphere, with the rate depending on temperature and. humidity. It is recommended that the material be dried in.

28KB Sizes 4 Downloads 287 Views

Recommend Documents

FT. TERLURAN GP 22 - BASF.pdf
BASF Canada BASF Mexicana S.A. de C.V.. 345 Carlingview Drive Insurgentes Sur 975. Toronto, Ontario M9W 6N9 Col. Ciudad de los Deportes. Canada Delegación Benito Juarez. Tel: 416- 675-3611 03710 México, D.F.. Fax: 416-674-2588 México. Tel: 011-52-5-3

'''. ' "gp : '
rr'lqoaleolcmd ors'l o9to,5m5.eo@{,agpca;qr. , edloi rrucqq-ndsr",. , l. '''. ' "gp i /dr6tneDJcotarocnoffiqer.g . ' : '. or5Ocrun'Oorciirorl odc6rnJo. cruJ^. *rfor$*.-.

'''. ' "gp : '
rr'lqoaleolcmd ors'l o9to,5m5.eo@{,agpca;qr. , edloi rrucqq-ndsr",. , l. '''. ' "gp i /dr6tneDJcotarocnoffiqer.g . ' : '. or5Ocrun'Oorciirorl odc6rnJo. cruJ^. *rfor$*.-.

GP Job Capsules.pdf
between various organizational units, and management and program ... regulatory agencies of other states; researching public and court records; analyzing and ... and national association officials and agencies to obtain and exchange data; ...

GP Job Capsules.pdf
proposing, and implementing database structures; selecting database software; developing and. maintaining database access and updating procedures to ...

ft-2600_manual.pdf
Page 1 of 62. 144 MHZ BAND FM TRANSCEIVER. FT-2600M. OPERATING MANUAL. VERTEX STANDARD CO., LTD. 4-8-8 Nakameguro, Meguro-Ku, Tokyo ...

ttr7t*5/ft,tt-
1) whc'ther the work marches the theme given for painting. 2) ilffective ... 3) ltrair and effectivc usc of multimedia resources, links ancl other settings. 4) Design ...

35.pdf
(i) This question paper contains two parts—A and B. (ii) Part—A and Part—B are compulsory for all. candidates. (iii) All parts of the questions should be attempted at one. place. PART—A. ( Accounting for Not-for-Profit Organisations,. Partner

35.pdf
Sign in. Page. 1. /. 4. Loading… Page 1 of 4. Page 1 of 4. Page 2 of 4. Page 2 of 4. Page 3 of 4. Page 3 of 4. Page 4 of 4. Page 4 of 4. Main menu. Displaying 35.pdf. Page 1 of 4.

GP Titles IS Department.pdf
Any Data Base Management System such as SQL-Server or. ORCALE. 4. Designing &. Implementing E- Voting System. Dr. Monther Dr. Muntaha Alawneh.

14.04.2016 GP GRAFFIGNANA G.P..pdf
2 10 34 GUARNIERI ALBERTO VET. 2. 1o 7833321 ... 8 17 222 DEMICHELI MARCO SENIOR. 2. 1o 7833714 08PC043 ASD VIVO ACSI 3. 9 19 212 ZANDONA SIMONE SEN 1 1o 7809476 04CO058 ASD TEAM CARIMATE ACSI 2. Page 3 of 4. Main menu. Displaying 14.04.2016 GP GRAFF

Promotion from GP Rs. 1800 (Level-1) to GP Rs. 1900.PDF ...
Page 1 of 1. KH tss I l. [19;!Ej!JJ!:1. GOVERNMENT OF INDIA/BHARAT SARKAR. JNINISTRVEF \YA. {RATLWAY BOARD}. No.E{NG}Fza15/cFP /8. The General ...

gp mains 2011 civil engg.pdf
There was a problem previewing this document. Retrying... Download. Connect more apps... Try one of the apps below to open or edit this item. gp mains 2011 ...

BFTA GP 7.pdf
Ian Taylor –World Champion in 2003, 2005 and 2008 and multiple winner of. BFTA and NEFTA ... top score. Page 3 of 9. BFTA GP 7.pdf. BFTA GP 7.pdf. Open.

Rapid ft: -8042959
May 12, 2011 - for stimulus manipulation and temporary storage. It is an essential system ..... key, masked with a piece of red tape, stood for “no” (i.e., different).

c ft Awalkthroughtheforest
\JI} Apsychological test and free-speaking activity. 55 use their imagination to describe a walk through a forest and then interpret each other's descriptions, ...

35.pdf
In today's connective global environment, it is impossible to isolate change by borders ... For this paper, we looked at transformational leadership and ... Entrepreneurial Orientation (EO) Questionnaire and Sashkin's (1995) ... Displaying 35.pdf.

34/? 35/? Du
The down link 26 can comprise different channels D1, . . . , DN. Each .... data from a telephone 1 are A/D-conver'ted 2, voice coded 3 and then supplied to a ...

35.pdf
El autor contesta desde cinco postulados que mere- cen ser analizados uno a uno. .... 35.pdf. 35.pdf. Open. Extract. Open with. Sign In. Main menu. Displaying ...

35.pdf
manager to plan the meetings, usually someone with no experience in this field. Hotels are. discovering that with small business meetings, they get lots of repeat business if they do a. good job catering to their needs. This is ... "dominate" the sma

[LibroGame].Scegli.la.tua.Avventura.-.35.-.La.Coppa.del.Vampiro.
[LibroGame].Scegli.la.tua.Avventura.-.35.-.La.Coppa.del.Vampiro.(giocabile).[by.Dirk06].pdf. [LibroGame].Scegli.la.tua.Avventura.-.35.-.La.Coppa.del.Vampiro.(giocabile).[by.Dirk06].pdf. Open. Extract. Open with. Sign In. Main menu. Displaying [LibroG

35.pdf
Confirmatory factor analysis was used to confirm a three factor solution for social ... financial performance of the firm. In spite of a growing. Page 3 of 26. 35.pdf.