TARGA® II HOLLOW FIBER CARTRIDGES 10-inch Water Ultrafiltration Cartridges PRODUCT DESCRIPTION

Membrane Chemistry: Molecular Weight Cutoff: Housing Shell: Fiber Support Netting: Permeate Collection Tube: Potting Material: Membrane Construction: Storage Solution: Regulatory Status:

PRODUCT SPECIFICATIONS

Part Number

OPERATING & DESIGN INFORMATION

Maximum Pressure (water): Temperature Range: Maximum Production Transmembrane Pressure: Maximum Backflush Transmembrane Pressure: Allowable pH Range: Maximum Total Chlorine @ 77º F (25º C) or lower: Typical Cleaning Total Chlorine @ 77°F (25°C) or lower: Maximum Backflush Total Chlorine @ 77°F (25°C) or lower:

0720708 0720709

Proprietary Semi-Permeable Polyethersulfone 100,000 PVC Polypropylene/Polyethylene PVC Proprietary Compound Hollow Fiber Glycerin/Water Classified by UL to NSF/ANSI Standard 61 and in accordance with NSF/ANSI Standard 372

Model

Fiber Diameter Membrane Area Typical Production Range [inch (mm)] [ft2 (m2)] [gpm (m3/hr)]

TARGA II 10048-35 TARGA II 10072-35

0.035 (0.9) 0.035 (0.9)

554 (51.5) 871 (80.9)

15.4 - 32.2 (3.5 - 7.4) 24.2 - 51.4 (5.5 - 11.6)

45 psi (3.0 bar) @ 104º F (40º C) or less 32º F (0º C) - 104º F (40º C) 30 psi (2.1 bar) 25 psi (1.7 bar) 1.5 - 13 500 ppm @ pH >10 200 ppm @ pH >10 50 ppm @ pH >9

NOMINAL DIMENSIONS*

D Model

Fiber Diameter (ID)

Inches (mm)

TARGA II 10048-35 TARGA II 10072-35

0.035 inch (0.9 mm) 0.035 inch (0.9 mm)

10.75 (273) 10.75 (273)

L Inches (mm) 48 (1219) 72 (1829)

* Dimensions are provided for reference only and should not be interpreted as accurate specifications.

TARGA® II HOLLOW FIBER CARTRIDGES CARTRIDGE STORAGE CONDITIONS: New cartridges are packaged in a glycerin/water solution. The glycerin/water solution should be removed from new cartridges before their initial use with a water rinse followed by a caustic wash followed by caustic/chlorine wash. See the pre-startup cleaning instruction sheet packed with each cartridge shipment for more details. Prior to installation, cartridges should be stored in their original packaging under the following conditions:  Indoors, out of direct sunlight.  Temperatures between 50 – 85°F (10 – 30°C).  Relative humidity below 70%.  In a horizontal position. It is best to use new cartridges within one year of shipment. Consult KMS for recommendations for longer term storage. Used cartridges should be cleaned, rinsed and impregnated before storage with one of the following solutions:    

Glycerin @ 80 – 100% (best) Phosphoric acid @ pH 2 – 3 Benzoic acid or sodium benzoate @ 1,000 ppm Sodium bisulfite or sodium metabisulfite @ 1,000 – 5,000 ppm

Cartridges stored in sodium bisulfite or sodium metabisulfite should be flushed with clean water and impregnated with fresh solution at six-month intervals. Once impregnated the cartridges should be left on the system with all valves closed or removed from the system and sealed in plastic bags. Storage conditions described above for new cartridges should also be used for storage of used cartridges. Cartridges must be drained, rinsed, and cleaned after storage per the pre-startup cleaning instruction sheet packed with each cartridge shipment.

CARTRIDGE ASSEMBLY AND COMPONENTS: Item 1 2 3 4 5 6 7 8 9 10

Required for Required for Single Permeate Dual Permeate Removal Removal 10” HF Cartridge 1 each 1 each 10” HF SS Coupling 2 each 2 each 10” HF Face Seal 2 each 2 each 10” HF K-Ring 2 each 2 each Permeate O-rings 4 each 4 each 10” Plastic HF End Cap W Port 1 each 2 each 10” Plastic HF End Cap W/O Port 1 each 0 each 10” HF End Cartridge Support 2 each 2 each 10” HF Cartridge Support Hardware 2 each 2 each 2” Groove-End Coupling 3 each 4 each Description

Process pass kits for 10” cartridge are available: 10” Plastic Pass Kit for dual permeate removal - KMS part number - 1020560 10” Plastic Pass Kit for single permeate removal - KMS part number 1004913

The information contained in this publication is believed to be accurate and reliable, but is not to be construed as implying any warranty or guarantee of performance. We assume no responsibility, obligation or liability for results obtained or damages incurred through the application of the information contained herein. Refer to Standard Terms and Conditions of Sale and Performance Warranty documentation for additional information.

Koch Membrane Systems, Inc., www.kochmembrane.com Corporate Headquarters: 850 Main Street, Wilmington, Massachusetts 01887-3388, US, Tel. Toll Free: 1-888-677-5624, Telephone: 1-978-694-7000, Fax: 1-978-657-5208 European Headquarters: Koch Chemical Technology Group Ltd., Units 3-6, Frank Foley Way, Stafford ST16 2ST, GB, Telephone: +44-178-527-2500, Fax: +44-178-522-3149 • Aachen DE • Lyon FR • Madrid ES • Milan IT • Wijnegem BE • Beijing & Shanghai CN • Mumbai & New Delhi IN • Melbourne & Sydney AU • Singapore • Sao Paulo BR • Dubai UAE •

For related patent and trademark information, visit www.kochmembrane.com/legal Koch Membrane Systems, Inc. is a Koch Chemical Technology Group, LLC company. © 2015 Koch Membrane Systems, Inc. All rights reserved worldwide.

01/15 Rev 15-1

KOCH UF _ TARGA II-10inch-datasheet.pdf

Sodium bisulfite or sodium metabisulfite @ 1,000 – 5,000 ppm. Cartridges stored in sodium bisulfite or sodium metabisulfite should be flushed. with clean water and impregnated with fresh solution at six-month intervals. Once. impregnated the cartridges should be left on the system with all valves closed or. removed from ...

345KB Sizes 1 Downloads 137 Views

Recommend Documents

KOCH UF _ TARGA II-brochure.pdf
Page 1 of 3. Inside-Out Hollow Fiber. Ultrafiltration for High Quality. Water Applications. Solutions. TARGA® II. Water & Wastewater. Page 1 of 3 ...

KOCH UF _ TARGA II-brochure.pdf
第 2 / 89 页. Whoops! There was a problem loading this page. Retrying... Whoops! There was a problem loading this page. Retrying... KOCH UF _ TARGA II-brochure.pdf. KOCH UF _ TARGA II-brochure.pdf. Open. Extract. Open with. Sign In. Main menu. Disp

UF SDS.pdf
There was a problem previewing this document. Retrying... Download. Connect more apps... Try one of the apps below to open or edit this item. Main menu.

Semidefinite - UF CISE
1 Computer Science Department, University of Southern California, Los Angeles, CA ... 2. Gaurav Agarwal, David Kempe: Modularity-Maximizing Graph ... graph were random conditioned on its degree distribution ..... over a period of 2 years.

KOCH-PULSION-datasheet.pdf
European Headquarters: Koch Chemical Technology Group Ltd., Units 3-6, Frank Foley Way, ... KOCH-PULSION-datasheet.pdf. KOCH-PULSION-datasheet.pdf.

UREA Perstrip UF Type II
Composition Materials Co., Inc. - 125 Old Gate Lane - Milford, CT 06460 ... RESPIRATORY PROTECTION: Recommend a 3M #8710 dust and mist respirator.

UF in Belize -
Dec 20, 2014 - Experience exclusive lectures with industry professionals. Participate in interactive classroom discussions, experiential site visits, and hands-on ...

Charles Koch Fdn (1).pdf
There was a problem previewing this document. Retrying... Download. Connect more apps... Try one of the apps below to open or edit this item. Main menu.

UF Case Study.pdf
There was a problem previewing this document. Retrying... Download. Connect more apps... Try one of the apps below to open or edit this item. UF Case Study.

=(3+(1.4)(6.6)/(1.4+6.6))uF= =( (5.7)(4.155)/(5.7+4.155))uF ... - GitHub
(contrary to the drawing) that the separation between the plates is small compared to a linear dimension of the plate. 1) What is C, the capacitance of this parallel ...Missing:

Vibration of the Koch drum - Mark McClure
We begin by setting up the boundary of the snowflake. The level .... Norm@interiorGrid@@#DD - KochVertices@@nDDD § stepSize к 2 &D@@1DD;.

Vibration of the Koch drum - Mark McClure
The fundamental modes of vibration of this drum can be modelled by the eigenfunctions of the .... We begin by setting up the boundary of the snowflake.

POSTULAT KOCH DAN PATHOGENISITAS.pdf
PRAKTIKUM ANALISIS PENYAKIT IKAN 1. PRAKTIKUM API 1 | FAKULTAS PERIKANAN DAN KELAUTAN, UNIVERSITAS AIRLANGGA . Menurut Angka (2001) dalam Abdullah (2008) penelitian tentang bakteri Aeromonas. hydrophila telah banyak dilakukan dan diketahui bahwa bakt

Vibration of the Koch drum - Mark McClure
A preprint version of a “Mathematical graphics” column from .... More precisely, there are seven functions f0 , f1 , …, f6 that map the snow- flake onto the ...

Charles Koch Fdn (1).pdf
Sign in. Loading… Whoops! There was a problem loading more pages. Retrying... Whoops! There was a problem previewing this document. Retrying.

Crick, Koch, A Framework for Consciousness.pdf
probably use the dorsal stream in the pari- etal region14. ... Neural networks in a cortex have both. short and .... Crick, Koch, A Framework for Consciousness.pdf.

the science of success charles koch pdf
There was a problem previewing this document. Retrying... Download. Connect more apps... Try one of the apps below to open or edit this item. the science of ...