TOWN OF HOPKINTON PLANNING BOARD Monday September 25, 2017 7:00 PM HCAM Studios, Studio A, Lower Level, 77 Main Street, Hopkinton, MA AGENDA
7:00
Continued Public Hearing - Saddle Hill Road Lots 1-4 -Scenic Road Permits - Saddle Hill Realty LLC Proposed removal of 152 ft. section of stone wall, over 4 lots within the layout of Saddle Hill Road for the construction of driveways to 4-single family homes.
7:30
Continued Public Hearing - 50-60 West Main Street -Site Plan Review - Golden Pond Resident Care Corporation Proposed 34,100 sf addition to the existing building as part of the Phase 3 Golden Pond expansion project.
8:30
5 Minute Break
8:35
Public Hearing – 147 Lumber Street - Commercial Solar Photovoltaic Special Permit Application and Stormwater Management Permit Application - Clean Energy Collective Proposed 2.9 MW commercial solar photovoltaic installation on approximately 11.4 acres of land (Assessor’s Map R29-15-0 and R30-1-A).
9:15
Public Hearing - 97 East Main Street - Minor Site Plan Review - Weston Nurseries Proposed construction of a 3,200 square foot greenhouse.
Business to be considered by the Board at any time during the meeting: ● Center School Re-Use Advisory Team Survey ● Request to Extend Time to Complete Construction of Legacy Farms South - Roy MacDowell ● Request for Minor Modification to Plan for Box Mill Road - Richard Barbieri ● Approve Minutes (August 28, 2017) ● Board member comments, reports, liaison reports, or future agenda items ● Correspondence
TOWN OF HOPKINTON DEPARTMENT OF
LAND USE, PLANNING AND PERMITTING TOWN HALL 18 MAIN STREET HOPKINTON, MA 01748 508-497-9745 www.hopkintonma.gov
DATE:
September 20, 2017
TO:
Planning Board
FROM:
Jennifer Burke, Principal Planner
RE:
Items on September 25, 2017 Planning Board Agenda
1. Continued Public Hearing – Saddle Hill Road Lots 1-5 – Scenic Road Permit This hearing has been continued from your last meeting. A majority vote is required for approval and a decision is due 21 days from the close of public hearing. Since the last meeting the developer’s engineer has met with the Fire Chief and they have come to an agreement regarding the driveways. Enclosed is an emergency vehicle exhibit for each driveway. The Fire Chief has also provided a letter indicating his support for the new design. The cumulative total of stone wall to be removed now is 133 linear feet. The Scenic Road By-law provides as follows: § 160-6. Criteria for work projects. The Planning Board’s decision on any application for proposed work affecting scenic roads shall be based on consideration of the following criteria: A. The degree to which the proposed work would adversely affect the scenic and aesthetic values upon which the scenic road designation was originally based. B. The necessity for the proposed work in terms of public safety, welfare, or convenience. C. Compensatory action proposed, such as replacement of trees or walls. D. Availability of reasonable alternatives to the proposed work which could reduce or eliminate anticipated damage to trees or stone walls. E. Whether the proposed work would compromise or harm other environmental or historical values.
F. Consistency of the proposed work with previously adopted Town plans and policies. 2. Continued Public Hearing – Site Plan Review – 50-60 West Main Street – Golden Pond This application for a Site Plan Review was continued from your meeting on August 28, 2017. A decision is due 90 days from the close of the public hearing, and a majority vote is required for approval. Cliff Kistner needs to review the tape and sign the affidavit in order to vote. All other members are eligible. I have updated the outline from the previous meeting (see enclosed). We will continue to follow the outline. The Site Plan Standards are attached to the end of the outline. The developer submitted updated information to us and BETA in early September. BETA has reviewed it and provided the enclosed comments. There still seems to be several outstanding issues remaining. We have received the following comments from other Town Departments: Bryan Besso Health Agent, Board of Health –The Board of Health does not have any issues with this project site plan review. The facility does not have a septic system and is on a public water supply. Thank you for offering our department an opportunity to comment. At a department head review meeting July 20, 2017 with representatives of the Police Dept., Fire Dept., DPW and myself, the following comments were made: The DPW is evaluating the availability of water and should know something soon. It should be determined if the internal site piping for sewage can meet the estimated flow. The Fire Department had concerns relative to the Construction Management Plan including parking for construction workers vehicles, clear fire access maintained throughout the duration of the project and enforcement. Fire protection calculations will need to be done by the Town’s fire protection engineer. The Fire Department will need to review the whole project for access. There may be a challenging spot between Phase II and Phase III. A swept path analysis with the parking will be required. Hours of operation for construction should be noticed to all contractors and subcontractors. No idling before 7:00 AM. Fire Department ambulance is currently rated at capacity. Depending on type of services in new Phase, could see up to an additional 108 calls per year. Police & DPW should indicate if they have the institutional capacity to support the project. The Conservation Commission has continued their public hearing for a Notice of Intent until October 2nd pending ongoing BETA review. I have compiled the following in advance for the Board’s information: Board Action A. Vote to determine that the plan complies with the Site Plan Standards; 2
B. Vote to approve the site plan with conditions. Site Plan Standards My opinion as to compliance with the Site Plan Standards contained in Section 210-136.1 is indicated below. A. Site disturbance in wetland buffer zones and to slopes in excess of 25% shall be minimized. Complies. B. Unique natural and historic features shall be preserved whenever feasible. Complies. C. Tree, vegetation and soil removal shall be minimized. Complies. D. The site activities shown on the Site Plan shall be screened from view from abutting properties in residential use. Methods of screening may include solid fencing, landscaping or other proposals of the Applicant, subject to review by the Planning Board. Such screening may be located on or off-site. If located off-site, written permission of the off-site property owner shall be provided to the Board. Complies. E. All utilities shall be underground. Complies – Existing. F. Exposed storage areas, machinery, service areas, truck loading areas, utility buildings and structures and other similar uses shall be visually screened from abutting properties and those using public ways. Screening methods may consist of solid fencing, landscaping or similar proposals submitted by the Applicant, subject to review by the Planning Board. Complies. G. The site plan shall show measures to reduce and abate noise and odors generated from the site that will impact surrounding properties. Complies. H. The site plan shall comply with all zoning requirements. Complies. I. The site plan shall maximize the convenience and safety of vehicular and pedestrian movement within the site and to and from adjacent public ways. If supporting documentation, such as a traffic or parking study, submitted to the Planning Board indicates that the vehicular and pedestrian traffic movement depicted on the site plan and proposed in the application will have a significant negative impact or impacts on the site or within the adjacent ways, such impacts shall be mitigated by the Applicant. Complies – Existing. J. Parking areas shall be designed so that they are safe and convenient and do not detract from the use and enjoyment of proposed structures. Parking areas shall be designed to facilitate safe pedestrian access to the structures and other on-site facilities. Complies –Existing. K. The site plan shall minimize the number of curb cuts on public ways. Complies – Existing. L. Driveways shall be designed to ensure safe sight distances at interior and exterior intersections and along driveways, in accordance with applicable AASHTO requirements. Complies – Existing. M. Sidewalks shall be provided along the entire frontage of the subject property along existing public ways. The Planning Board may approve alternative provisions or waive the requirements of this Standard in situations where sidewalk construction or use is not feasible or practical. Complies – Existing. N. Levels of illumination shall be provided as follows: 1. No property may have exterior lighting that exceeds the average illumination level recommended by the Illuminating Engineering Society of North America for such use as set forth in “Lighting Facilities for Parking Facilities,” Illuminating Engineering Society, 2014 and “The Lighting Handbook,” 10th Ed., Illuminating Engineering Society, 2011. Complies – Existing.
3
2. For pole mounted lights in parking and driveway areas, the height of the light source shall not exceed 15 feet, which shall be measured from the ground at the base of the pole to the bottom of the fixture. Complies – Existing. 3. Pedestrian area lighting shall utilize fully shielded fixtures, and the height of light source shall not exceed 12 feet, measured from the ground at the base of the pole to the bottom of the fixture. Complies – Existing. 4. No exterior lighting may interfere with the safe movement of motor vehicles on public ways or private ways open to the public. Complies – Existing. 5. Mercury vapor lamps shall be prohibited. Complies – Existing. 6. Uplighting shall be permitted only when used in one of the following manners: Complies – Existing. (a) To light a primary entrance, when the fixture or lamp is wall-mounted under an architectural element (e.g., roofs over walkways, entries or overhanging, nontranslucent eaves) so that the uplighting is fully captured; (b) To light local, state or national flags; or (c) To highlight or illuminate a building facade or landscaping, or to highlight or illuminate statues or monuments. 7. Floodlighting shall be permitted only if a fully shielded fixture is utilized and no lighting will fall onto the property of others. Complies – Existing. 8. Safety and security lighting shall use motion sensors, photocells, or photocells or timers to control duration of nighttime illumination. Complies – Existing. 9. Exterior lighting of recreation facilities shall utilize fully shielded fixtures and, except as authorized by Special Permit or Site Plan Approval, shall be turned off by 10:00 p.m. or at the conclusion of an activity begun before 10:00 p.m.; provided, however, that in any event the exterior lighting shall be turned off by midnight. Not Applicable. 10. Blinking, flashing, moving, revolving and flickering lights, as well as lighting that changes intensity or color shall be prohibited except for lighting for public safety or traffic control and lighting required by the U.S. Federal Aviation Administration for air traffic control and warning purposes. Not Applicable. 11. Notwithstanding any provisions of this subsection to the contrary, sidewalks that run along the perimeter of a site and are in a public right of way or on abutting property may be illuminated, and illumination may spill onto abutting non-residential property if requested in writing by the abutting property owner. Complies – Existing. Exterior lighting that does not conform to the provisions of this subsection may be allowed by special permit from the Planning Board if the Planning Board finds that such exterior lighting will be consistent with the Purposes of this Article, or that there are other demonstrable community, health, safety or welfare benefits that will be served by the exterior lighting. No special permit may be granted pursuant to this subsection unless the Planning Board determines that the proposed exterior lighting is appropriate for the size and use of the property, any buildings thereon, and the neighborhood setting. O. Adequate access shall be provided to each structure for emergency vehicles and personnel. Complies – Existing. P. The site plan shall conform to applicable Massachusetts Department of Environmental Protection Storm water Management Regulations. The site plan shall show adequate measures to prevent pollution of surface water and groundwater, to minimize erosion and sedimentation and to prevent changes in the potential for flooding. Storm water management 4
facilities shall be designed so that neighboring properties, public ways and public storm drainage systems will not be adversely impacted. Complies. Q. Mechanical equipment or other utility hardware on the roof, grounds or buildings shall be screened from view from the ground. Complies. R. All dumpsters shall be screened from public view. Complies - Existing. Proposed Conditions: Below is a list of proposed conditions for the Board to consider prior to approval. There may be others that become apparent at the hearing the Board may want to add. 1. The applicant shall be responsible for mitigating all construction related impacts, including erosion, siltation and dust control in a timely manner. (Site Plan Standard G) 2. The applicant shall regularly remove construction trash and debris from the site in accordance with good construction practice. No tree stumps, demolition material, trash or debris shall be burned or buried on the site. (Site Plan Standard G) 3. In the event that the amount of snow on the Site exceeds the amount that can be accommodated safely in the snow storage areas indicated on the Site Plan, the excess snow shall be removed from the parking area. (Site Plan Standard J) 4. Mechanical equipment or other utility hardware on the roof, grounds or buildings shall be screened from view from the ground. (Site Plan Standard Q) 5. The Director of Municipal Inspections inspects Site Plans under construction for compliance with the approved Decision of Site Plan Review. If the Director of Municipal Inspections determines at any time before or during construction that a registered professional engineer or other such outside professional is required to assist with the inspections of the storm water management system or any other component of the Site Plan, the Applicant shall be responsible for the cost of those inspections. (All Site Plan Standards & § 210-137) 6. In accordance with § 210-138 of the Zoning Bylaw, the Applicant shall provide a performance guarantee in the amount of $3,000 to the Town prior to the commencement of construction pursuant to this Decision. The guarantee shall consist of a deposit of money or negotiable securities in a form selected by the Planning Board to guarantee that any unforeseen problems which arise, such as erosion and sedimentation and the correction of site lighting problems, are addressed. The funds will be held by the Town and returned to the Applicant upon completion of the project. (All Site Plan Standards & § 210-137) 7. Construction may occur only between the hours of 7:00 AM and 7:00 PM Monday through Friday and Saturdays between 8:00 AM and 4:00 PM pursuant to Chapter 141 Article 1 of the Town of Hopkinton General Bylaws.
5
3. Public Hearing – 147 Lumber Street – Commercial Solar Photovoltaic Special Permit Application and Stormwater Management Permit Application – Clean Energy Collective Two applications have been submitted to the Board, relative to the proposal to construct a 2.9 MW solar facility at 147 Lumber Street, and the two public hearings are being held concurrently: Special Permit application pursuant to Zoning Bylaw Article XXXI – A decision is due 90 days from the close of the public hearing and a 2/3 vote is required for approval. Stormwater Management Permit application pursuant to General Bylaw Chapter 172 – A decision is due by October 23, 2017 and a majority vote is required for approval. If the public hearing is continued, then an additional extension of time for the Board to file its decision may be required. The solar facility will be located on 11.4 acres out of the total 41.5 acres on the property at 147 Lumber Street. There is an existing residence on the property as well. The land is zoned Agricultural, and is also within the Water Resources Protection Overlay District (WRPOD-1). The surrounding use is primarily residential. However, the property also abuts the Sportsman’s Club. The solar facility will be accessed via the existing driveway off Lumber Street. The array will be surrounded by a fence. The applicant has filed a Notice of Intent with the Conservation Commission and their hearing is in process. I have complied a project outline and it is enclosed. BETA has provided the enclosed comments dated September 19, 2017 and covers both applications. This letter has been sent to the applicant and his engineer. No response has been received. Several of the lots on which the array is located are newly acquired. The applicant has also provided a draft ANR plan to combine the lots. This plan will be submitted if the Board indicates a favorable action on the Special Permit. This is to avoid a violation of setbacks from interior lot lines. Approval Criteria – Special Permit Before the Planning Board issues a special permit, it must determine the following: The commercial solar photovoltaic installation conforms to the provisions of Article XXXI of the Zoning Bylaw (listed below, abbreviated); A. Three acre minimum parcel; B. Setback, yard, buffer and screening requirements applicable in the zoning district apply; C. Security fences shall be set back from the property line a distance equal to the setback requirement applicable to buildings within the zoning district in which the installation is located; D. Site Plan Review is not required; 6
E. The visual impact of the installation, including all accessory structures and appurtenances, shall be mitigated. All accessory structures and appurtenances shall be architecturally compatible with each other. Whenever reasonable, structures shall be shielded from view by vegetation and /or joined and clustered to avoid adverse visual impacts. Methods such as the use of landscaping, natural features and fencing may be used. F. Lighting shall not be permitted unless required by the Planning Board or by the State Building Code. Where used, lighting shall be directed downward and full cut-off fixtures shall be used. G. All utility connections from the installation shall be underground unless otherwise specifically permitted by the Board in the special permit. Electrical transformers and inverters to enable utility interconnections may be above ground if required by the utility provider. H. Clearing of natural vegetation shall be limited to the minimum necessary for the construction, operation and maintenance of the commercial solar photovoltaic installation except as otherwise prescribed by applicable laws, regulations and bylaws or the special permit. I. The installation owner or operator shall maintain the facility in good condition. Maintenance shall include painting, structural repairs, continued compliance with landscaping and screening requirements, and integrity of security measures. The owner or operator shall be responsible for the maintenance of any access roads serving the installation. The commercial solar photovoltaic installation will not be detrimental to the neighborhood or the Town; Environmental features of the site and surrounding areas are protected, and specifically surrounding areas will be protected from the proposed use by provision of adequate surface water drainage; Grant of the special permit will be in harmony with the general purpose and intent of the Bylaw.
The Board must give due consideration to promoting the public health, safety, convenience and welfare; and shall not permit a use that is injurious, noxious, offensive or detrimental to its neighborhood except as otherwise specified in the bylaw (Sec. 210-223). Special permits shall be subject to whatever appropriate conditions and safeguards the Board may prescribe. The Board’s authority in this matter is tempered by the provisions of MGL c.40A Sec. 3, which states “No zoning ordinance or bylaw shall prohibit or unreasonably regulate the installation of solar energy systems or the building of structures that facilitate the collection of solar energy, except where necessary to protect the public health, safety or welfare.” The Attorney General advised the Town in its approval of the solar bylaw of the following: A. “These special permit standards in Section 210-203 (D) appear to be consistent with the Town’s general zoning power and the power to impose reasonable regulations on solar 7
uses “where necessary to protect the public health, safety or welfare.” G.L. c. 40, § 3. However, the Town should consult closely with Town Counsel throughout the special permit review process to ensure that the standards in Section 210-203 (D) are not applied in a manner that contravenes the protections granted to solar energy systems in G.L. c. 40A, § 3.” B. “Section 210-203 (E) authorizes the Planning Board to impose conditions and other safeguards on a special permit issued for a Solar Installation. Specifically, Section 210203 (E) authorizes the Planning Board to require a performance bond, or other type of security deposit to guarantee proper maintenance and removal of the Solar Installation. Any financial surety requirements imposed by the Planning Board do not become Town funds unless and until the applicant defaults on the obligation imposed under the by-law or special permit. If the Town must use the financial surety to pay for work required under the bylaw or special permit, the Town must appropriate the funds before an expenditure is made to do the work. General Laws Chapter 44, Section 53, provides that “[a]ll moneys received by a city, town or district officer or department, except as otherwise provided by special acts and except fees provided for by statute, shall be paid by such officers or department upon their receipt into the city, town or district treasury.” Under Section 53 all moneys received by the Town become part of the general fund, unless the Legislature has expressly made other provisions that are applicable to such moneys. In the absence of any general or special law to the contrary, performance security funds of the sort contemplated in Section 210-203 (E) must be deposited with the Town Treasurer and made part of the Town’s general fund pursuant to G.L. c. 44, § 53. The Town must then appropriate the money for the specific purpose of complying with the conditions relating to removal of the Solar Installation. We suggest that the Town discuss the application of this section.” Approval Criteria - Stormwater Management Permit BETA Group has reviewed the application and has provided the enclosed letter report. The project is subject to the DEP Stormwater Management Standards. The following are the 10 standards and BETA’s comments with respect to relative compliance provided by the submitted documentation: Stormwater Standard BETA comments on proposed plan Compliance #1 – No untreated stormwater The project does not propose untreated Complies – No new stormwater stormwater discharges to wetlands. conveyances (e.g. outfalls) may discharge untreated stormwater directly to or cause erosion in wetlands or waters of the Commonwealth. #2 – Post-development peak The model for the proposed condition Additional discharge rates – Stormwater uses a meadow, non-grazed to information management systems must be approximate the surface characteristic needed designed so that postwhen fully constructed. However, once development peak discharge constructed, the surface will not receive rates do not exceed prerainfall evenly. 8
development peak discharge rates. #3 – Recharge to groundwater – Loss of annual recharge to groundwater should be minimized through the use of infiltration measures to the maximum extent practicable. #4 – 80% Total Suspended Solids (TSS) removal – For new development, stormwater management systems must be designed to remove 80% of the annual load of total suspended solids. #5 – Higher Potential Pollutant Loads – Stormwater discharges from land uses with Higher Potential Pollutant Loads required the use of specific stormwater management BMP’s. #6 – Critical Areas – Stormwater discharges to critical areas must utilize certain stormwater BMP’s approved for critical areas. #7 – Redevelopment – Redevelopment of previously developed sites must meet the Stormwater Management Standards to the maximum extent practicable. #8 – Construction Period Erosion and Sediment Controls – Erosion and sediment controls must be implemented to prevent impacts during construction of land disturbance activities. #9 – Operations/Maintenance Plan – A long-term operation and maintenance plan shall be developed and implemented to ensure that stormwater
The site is predominately comprised of soils rated in Hydrologic Soil Groups A and B in upland areas.
Additional information needed
Stormwater runoff from the site discharges to the adjacent wetland areas. The plan include recharge infiltration basins to provide recharge.
Complies
Not applicable
Not applicable
Project is not likely to generate pollutants that would adversely impact groundwater supplies. It provides treatment of runoff and recharge via infiltration basins.
Complies
Not applicable
Not applicable
The project site is greater than 1 acre in area and land disturbance activities will require a NOI with EPA and a SWPPP.
Additional information needed
An O & M Plan was included in the drainage report.
Additional information needed
9
management systems function as designed. #10 – Illicit Discharges – All illicit discharges to the stormwater management systems are prohibited.
An unsigned illicit discharge statement has been provided.
Additional information needed
With respect to Planning Board action, the Stormwater Regulations adopted by the Board in 2008 states: The Planning Board’s action, rendered in writing, shall consist of either: 1. Approval of the SMP application based upon determination that the proposed plan meets the Standards in Section 7.0, will adequately protect the water resources of the community and is in compliance with the requirements set forth in the Bylaw and the Regulations, 2. Approval of the SMP application subject to any conditions, modifications or restrictions required by the Planning Board which will ensure that the project meets the Standards in Section 7.0 and adequately protects water resources, set forth in the Bylaw and the Regulations, 3. Disapproval of the SMP application based upon a determination that the proposed plan, as submitted, does not meet the Standards in Section 7.0, does not adequately protect water resources, or does not comply with the provisions of the Bylaw or the Regulations. 4. The Planning Board may disapprove an application “without prejudice” where an applicant fails to provide requested additional information or review fees that in the Planning Board’s opinion are needed to adequately describe or review the proposed project. See the table above for the referenced criteria. Standard SMP conditions are attached to the end of this memo. 4. Public Hearing –Minor Site Plan – 97 Main Street – New Greenhouse The application for a Minor Site Plan was submitted on September 8, 2017. A decision is due on November 7, 2017, and a majority vote is required for approval. The proposed alterations include the installation of a 3,200 sf greenhouse. The building will be located between the garden center and the shed. It will be on a slab 5 ft deep. No additional traffic is anticipated. No changes to stormwater are proposed. No changes to parking are proposed. There will be internal lighting and no new signs. The project is seeking a minor site plan review because the amount of square footage being changed is less than 5,000. Under this review the Board can determine whether or not BETA review is necessary. There are no impacts to the storm water or traffic and parking. The changes are all architectural. It would appear that a BETA review is not warranted for this application. We have received the following comments from other Town Departments: 10
Shaun McAuliffe, BOH Director, Board of Health – No comments or concerns for the proposed facility. The proposed structure does not require septic and/or water service. Design Review Board met on Tuesday September 19, 2017 and had no recommendations. I have compiled the following in advance for the Board’s information: Board Action A. Vote to determine that the project meets the requirements of a Minor Project under §210-134; B. Vote to determine that the plan complies with the Site Plan Standards; C. Vote to approve the site plan with conditions. Site Plan Standards My opinion as to compliance with the Site Plan Standards contained in Section 210-136.1 is indicated below. A. Site disturbance in wetland buffer zones and to slopes in excess of 25% shall be minimized. Not Applicable - No disturbance. B. Unique natural and historic features shall be preserved whenever feasible. Complies. C. Tree, vegetation and soil removal shall be minimized. Complies. D. The site activities shown on the Site Plan shall be screened from view from abutting properties in residential use. Methods of screening may include solid fencing, landscaping or other proposals of the Applicant, subject to review by the Planning Board. Such screening may be located on or off-site. If located off-site, written permission of the off-site property owner shall be provided to the Board. Complies. E. All utilities shall be underground. Complies F. Exposed storage areas, machinery, service areas, truck loading areas, utility buildings and structures and other similar uses shall be visually screened from abutting properties and those using public ways. Screening methods may consist of solid fencing, landscaping or similar proposals submitted by the Applicant, subject to review by the Planning Board. Complies. G. The site plan shall show measures to reduce and abate noise and odors generated from the site that will impact surrounding properties. Complies. H. The site plan shall comply with all zoning requirements. Complies I. The site plan shall maximize the convenience and safety of vehicular and pedestrian movement within the site and to and from adjacent public ways. If supporting documentation, such as a traffic or parking study, submitted to the Planning Board indicates that the vehicular and pedestrian traffic movement depicted on the site plan and proposed in the application will have a significant negative impact or impacts on the site or within the adjacent ways, such impacts shall be mitigated by the Applicant. Complies – Existing. J. Parking areas shall be designed so that they are safe and convenient and do not detract from the use and enjoyment of proposed structures. Parking areas shall be designed to facilitate safe pedestrian access to the structures and other on-site facilities. Complies –Existing. K. The site plan shall minimize the number of curb cuts on public ways. Complies – Existing. L. Driveways shall be designed to ensure safe sight distances at interior and exterior intersections and along driveways, in accordance with applicable AASHTO requirements. Complies – Existing. 11
M. Sidewalks shall be provided along the entire frontage of the subject property along existing public ways. The Planning Board may approve alternative provisions or waive the requirements of this Standard in situations where sidewalk construction or use is not feasible or practical. Complies – Existing. N. Levels of illumination shall be provided as follows: 1. No property may have exterior lighting that exceeds the average illumination level recommended by the Illuminating Engineering Society of North America for such use as set forth in “Lighting Facilities for Parking Facilities,” Illuminating Engineering Society, 2014 and “The Lighting Handbook,” 10th Ed., Illuminating Engineering Society, 2011. Complies – Existing. 2. For pole mounted lights in parking and driveway areas, the height of the light source shall not exceed 15 feet, which shall be measured from the ground at the base of the pole to the bottom of the fixture. Complies – Existing. 3. Pedestrian area lighting shall utilize fully shielded fixtures, and the height of light source shall not exceed 12 feet, measured from the ground at the base of the pole to the bottom of the fixture. Complies – Existing. 4. No exterior lighting may interfere with the safe movement of motor vehicles on public ways or private ways open to the public. Complies – Existing. 5. Mercury vapor lamps shall be prohibited. Complies – Existing. 6. Uplighting shall be permitted only when used in one of the following manners: Complies – Existing. (a) To light a primary entrance, when the fixture or lamp is wall-mounted under an architectural element (e.g., roofs over walkways, entries or overhanging, nontranslucent eaves) so that the uplighting is fully captured; (b) To light local, state or national flags; or (c) To highlight or illuminate a building facade or landscaping, or to highlight or illuminate statues or monuments. 7. Floodlighting shall be permitted only if a fully shielded fixture is utilized and no lighting will fall onto the property of others. Complies – Existing. 8. Safety and security lighting shall use motion sensors, photocells, or photocells or timers to control duration of nighttime illumination. Complies – Existing. 9. Exterior lighting of recreation facilities shall utilize fully shielded fixtures and, except as authorized by Special Permit or Site Plan Approval, shall be turned off by 10:00 p.m. or at the conclusion of an activity begun before 10:00 p.m.; provided, however, that in any event the exterior lighting shall be turned off by midnight. Not Applicable. 10. Blinking, flashing, moving, revolving and flickering lights, as well as lighting that changes intensity or color shall be prohibited except for lighting for public safety or traffic control and lighting required by the U.S. Federal Aviation Administration for air traffic control and warning purposes. Not Applicable. 11. Notwithstanding any provisions of this subsection to the contrary, sidewalks that run along the perimeter of a site and are in a public right of way or on abutting property may be illuminated, and illumination may spill onto abutting non-residential property if requested in writing by the abutting property owner. Complies – Existing. Exterior lighting that does not conform to the provisions of this subsection may be allowed by special permit from the Planning Board if the Planning Board finds that such exterior lighting will be consistent with the Purposes of this Article, or that there are other 12
O. P.
Q. R.
demonstrable community, health, safety or welfare benefits that will be served by the exterior lighting. No special permit may be granted pursuant to this subsection unless the Planning Board determines that the proposed exterior lighting is appropriate for the size and use of the property, any buildings thereon, and the neighborhood setting. Adequate access shall be provided to each structure for emergency vehicles and personnel. Complies – Existing. The site plan shall conform to applicable Massachusetts Department of Environmental Protection Storm water Management Regulations. The site plan shall show adequate measures to prevent pollution of surface water and groundwater, to minimize erosion and sedimentation and to prevent changes in the potential for flooding. Storm water management facilities shall be designed so that neighboring properties, public ways and public storm drainage systems will not be adversely impacted. Complies – Existing. Mechanical equipment or other utility hardware on the roof, grounds or buildings shall be screened from view from the ground. Not Applicable All dumpsters shall be screened from public view. Not Applicable.
Site Plan Vote & Conditions: Find that the site plan complies with the Site Plan Standards contained in § 210-136.1 with the conditions to be imposed, and approve the Site Plan with the conditions below. 1. The applicant shall be responsible for mitigating all construction related impacts, including erosion, siltation and dust control in a timely manner. (Site Plan Standard G) 2. The applicant shall regularly remove construction trash and debris from the site in accordance with good construction practice. No tree stumps, demolition material, trash or debris shall be burned or buried on the site. (Site Plan Standard G) 3. Mechanical equipment or other utility hardware on the roof, grounds or buildings shall be screened from view from the ground. (Site Plan Standard Q) 4. The Director of Municipal Inspections inspects Site Plans under construction for compliance with the approved Decision of Site Plan Review. If the Director of Municipal Inspections determines at any time before or during construction that a registered professional engineer or other such outside professional is required to assist with the inspections of the storm water management system or any other component of the Site Plan, the Applicant shall be responsible for the cost of those inspections. (All Site Plan Standards & § 210-137) 5. In accordance with § 210-138 of the Zoning Bylaw, the Applicant shall provide a performance guarantee in the amount of $3,000 to the Town prior to the commencement of construction pursuant to this Decision. The guarantee shall consist of a deposit of money or negotiable securities in a form selected by the Planning Board to guarantee that any unforeseen problems which arise, such as erosion and sedimentation and the correction of site lighting problems, are addressed. The funds will be held by the Town and returned to the Applicant upon completion of the project. (All Site Plan Standards & § 210-137)
13
6. Construction may occur only between the hours of 7:00 AM and 7:00 PM Monday through Friday and Saturdays between 8:00 AM and 4:00 PM pursuant to Chapter 141 Article 1 of the Town of Hopkinton General Bylaws.
5. Legacy Farms South Subdivision Extension The subdivision approval for Legacy Farms South includes the following condition: 10. Roadway and infrastructure construction shown on the Subdivision Plan shall be completed within five (5) years from the start of construction or this approval shall be automatically rescinded unless such time is extended by the Board at the request of the Applicant. If construction has not commenced within five (5) years from the date of this approval, such approval shall be automatically rescinded. Construction began in October 2011. Last year the Board granted an extension through September 30, 2017. Since the work will not be completed until the end of the year per Mr. McDowell’s letter, the Board will need to issue an extension of time to complete the work. He has requested until June 15, 2018. 6. Request for Minor Modification to Box Mill Road Mr. Barbieri is requesting a modification to the approved plan for Box Mill Road. The approved plan shows a farmers wall along the edge of pavement, up one side and around the cul-de-sac. He would like to change this to a masonry wall using the same stones and stopping before the last driveway. The Board needs to determine if the modifications are major or minor. If minor, the Board can review and vote with no further notice. If major, the Board needs to schedule a new hearing and notices need to go out. It would appear from a planning perspective, that the changes are minor in nature. 7. Future Meetings October 16 October 30 November 13 November 27
14
Article XXXI Commercial Solar Photovoltaic Installations [Added 5-6-2013 ATM Article 57; Amended 5-4-2015 ATM Article 39] § 210-200. Purpose and Intent The purpose and intent of this Article is to permit the creation of new commercial solar photovoltaic installations by providing standards for the placement, design, construction, operation, monitoring, modification and removal of such installations that address public safety and minimize impacts on residential neighborhoods and scenic, natural and historic resources. § 210-201. Applicability Construction and use of a commercial solar photovoltaic installation or any part thereof shall be permitted in any zoning district subject to the requirements set forth in this section. Nothing in this Article should be construed to prevent the installation of solar photovoltaic installations that are permitted as-ofright in any zoning district as an accessory use. § 210-202. Use Regulations Commercial solar photovoltaic installations shall conform to the following provisions: A.
A commercial solar photovoltaic installation may be erected, upon the issuance of a special permit by the Planning Board, on a lot containing a minimum of three (3) acres.
B.
All setback, yard, buffer and screening requirements applicable in the zoning district in which the installation is located shall apply.
C.
All security fences surrounding the installations shall be set back from the property line a distance equal to the setback requirement applicable to buildings within the zoning district in which the installation is located.
D.
The provisions of Article XX, Site Plan Review, shall not apply to commercial solar photovoltaic installations.
E.
The visual impact of the commercial solar photovoltaic installation, including all accessory structures and appurtenances, shall be mitigated. All accessory structures and appurtenances shall be architecturally compatible with each other. Whenever reasonable, structures shall be shielded from view by vegetation and/or joined and clustered to avoid adverse visual impacts. Methods such as the use of landscaping, natural features and fencing may be utilized.
F.
Lighting shall not be permitted unless required by the Planning Board or by the State Building Code. Where used, lighting shall be directed downward and full cut-off fixtures shall be used.
G.
All utility connections from the commercial solar photovoltaic installation shall be underground unless otherwise specifically permitted otherwise by the Planning Board in the special permit. Electrical transformers and inverters to enable utility interconnections may be above ground if required by the utility provider.
H.
Clearing of natural vegetation shall be limited to the minimum necessary for the construction, operation and maintenance of the commercial solar photovoltaic installation except as otherwise prescribed by applicable laws, regulations and bylaws or the special permit.
I.
The commercial solar photovoltaic installation owner or operator shall maintain the facility in good condition. Maintenance shall include, but not be limited to, painting, structural repairs, continued compliance with landscaping and screening requirements, and integrity of security measures. The owner or operator shall be responsible for the maintenance of any access roads serving the installation.
§ 210-203. Administration A.
A special permit is required from the Planning Board to erect or install a commercial solar photovoltaic installation. A record owner desiring to erect or install a commercial solar photovoltaic installation shall file with the Planning Board an application for a special permit, together with such plans, drawings, specifications, fees and additional information as required by the Planning Board.
15
B.
The Planning Board shall have the authority to waive specific provisions of the Use Regulations of this Article upon a determination that a waiver would not be inconsistent with the purpose and intent of this Article.
C.
The Planning Board shall conduct its review, hold a public hearing and file its decision with the Town Clerk as required by the provisions of this Chapter.
D.
Approval Criteria. Before the Planning Board may issue such a special permit, it shall determine each of the following: (1)
The commercial solar photovoltaic installation conforms to the provisions of this Article.
(2)
The commercial solar photovoltaic installation will not be detrimental to the neighborhood or the Town.
(3)
Environmental features of the site and surrounding areas are protected, and specifically surrounding areas will be protected from the proposed use by provision of adequate surface water drainage.
E.
Any special permit issued pursuant to this Article shall be subject to such conditions and safeguards as the Planning Board may prescribe. Such conditions may include the requirement of a performance bond, secured by deposit of money or negotiable securities, posted with the Town to guarantee proper maintenance and/or removal of the commercial solar photovoltaic installation. The amount of the performance bond shall not exceed the estimated cost of the commercial solar photovoltaic installation’s removal. Such conditions may also include additional screening of the facility.
§ 210-204. Discontinuance A commercial solar photovoltaic installation shall be deemed to have been discontinued if it has not been in service for a continuous 24-month period. Upon receipt of a Notice of Discontinuance from the Director of Municipal Inspections, the owner shall have the right to respond to the Notice within 30 days of receipt. The Director of Municipal Inspections shall withdraw the Notice of Discontinuance and notify the owner that the Notice has been withdrawn if the owner provides information that demonstrates to the satisfaction of the Director of Municipal Inspections that the commercial solar photovoltaic installation has not been discontinued. If the commercial solar photovoltaic installation is determined to be discontinued, the owner shall remove the installation, including all structures, equipment, security barriers and transmission lines, and stabilize or re-vegetate the site as necessary to minimize erosion and sedimentation, at the owner’s sole expense within three months of receipt of the Notice of Discontinuance. Failure to remove the installation and stabilize the site within said time period may subject the owner to action pursuant to Article XXIV.
Article XXXIV Special Permit Granting Authority [Added 5-4-2015 ATM Article 39] § 210-223. Special Permits. A.
Pursuant to MGL c. 40A, § 9, the Special Permit Granting Authority (SPGA) shall hear and decide applications for Special Permits for which express provision is made in this Chapter. The SPGA may be the Board of Appeals or the Planning Board.
B.
The SPGA shall adopt rules not inconsistent with the General Laws and the provisions of this Chapter for conducting its business and shall file a copy thereof with the Town Clerk.
C.
A Special Permit shall lapse within two years of the grant thereof unless good cause is shown why substantial use thereof, or related construction, has not begun; provided, however, that an applicant may request an extension of the term of a Special Permit from the SPGA, and the SPGA may extend such term as it deems appropriate.
D.
Public hearings on all applications for Special Permits shall be held in accordance with MGL c. 40A, § 11.
E.
The decision of the SPGA shall be made within 90 days after the close of the public hearing. The required time limits for a public hearing and the filing of a decision may be extended by written agreement between the applicant and the SPGA, and shall be filed with the Town Clerk.
F.
Failure of the SPGA to act within the specified period shall be deemed to be a grant of the Special Permit.
G.
Unless otherwise specified in this Chapter, a special permit may be granted only if the SPGA determines that:
16
(1) All applicable criteria and standards set forth in this Chapter have been satisfied, and (2) Grant of the Special Permit will be in harmony with the general purpose and intent of this Chapter. H.
In reviewing an application for a Special Permit, the SPGA shall give due consideration to promoting the public health, safety, convenience and welfare; and shall not permit a use that is injurious, noxious, offensive or detrimental to its neighborhood except as otherwise specified in this Chapter.
I.
Special permits shall be subject to whatever appropriate conditions and safeguards the SPGA may prescribe.
Stormwater Management Permit – Standard Conditions 1.
All erosion and sediment controls shall comply with the following performance criteria: a.
Minimize total area of disturbance and protect natural features and soil.
b.
Sequence activities to minimize simultaneous areas of disturbance. Mass clearings and grading of the entire site shall be avoided.
c.
Minimize peak rate of runoff in accordance with the Massachusetts Stormwater Standards.
d.
Minimize soil erosion and control sedimentation during construction, provided that prevention of erosion is preferred over sedimentation control.
e.
Divert uncontaminated water around disturbed areas.
f.
Maximize groundwater recharge.
g.
Install and maintain all Erosion and Sediment Control measures in accordance with the manufacturer’s specifications and good engineering practices.
h.
Prevent off-site transport of sediment.
i.
Protect and manage on and off-site material storage areas (overburden and stockpiles of dirt, borrow areas, or other areas used solely by the permitted project are considered a part of the project).
j.
Comply with applicable Federal, State and local laws and regulations including waste disposal, sanitary sewer or septic system regulations, and air quality requirements, including dust control.
k.
Prevent significant alteration of habitats mapped by the Massachusetts Natural Heritage & Endangered Species Program as Endangered, Threatened or Of Special Concern, Estimated Habitats of Rare Wildlife and Certified Vernal Pools, and Priority Habitats of Rare Species from the proposed activities.
l.
Institute interim and permanent stabilization measures, which shall be instituted on a disturbed area as soon as practicable but no more than 14 days after construction activity has temporarily or permanently ceased on that portion of the site.
m. Properly manage on-site construction and waste materials.
2.
n.
Prevent off-site vehicle tracking of sediments.
o.
Dust shall be controlled at the site.
p.
Divert offsite runoff from highly erodible soils and steep slopes to stable areas.
The project shall comply with the following Erosion and Sediment Control requirements: a.
Prior to any land disturbance activities commencing on the site, the developer shall physically mark limits of no land disturbance on the site with tape, signs, or orange construction fence, so that workers can see the areas to be protected. The physical markers shall remain in place until a Certificate of Completion has been issued.
17
b.
Appropriate erosion and sediment control measures shall be installed prior to soil disturbance. Measures shall be taken to control erosion within the project area. Sediment in runoff water shall be trapped and retained within the project area. Wetland areas and surface waters shall be protected from sediment.
c.
Sediment shall be removed once the volume reaches ¼ to ½ the height of a hay bale. Sediment shall be removed from silt fence prior to reaching the load-bearing capacity of the silt fence which may be lower than ¼ to ½ the height.
d.
Sediment from sediment traps or sedimentation ponds shall be removed when design capacity has been reduced by 50 percent.
e.
Soil stockpiles must be stabilized or covered at the end of each workday. Stockpile side slopes shall not be greater than 2:1. All stockpiles shall be surrounded by sediment controls.
f.
Disturbed areas remaining idle for more than 14 days shall be stabilized with seeding, wood chips, bark mulch, tarpaulins, or any other approved methods.
g.
For active construction areas such as borrow or stockpile areas, roadway improvements and areas within 50 feet of a building under construction, a perimeter sediment control system shall be installed and maintained to contain soil.
h.
A tracking pad or other approved stabilization method shall be constructed at all entrance/exit points of the site to reduce the amount of soil carried onto roadways and off the site.
i.
Permanent seeding shall be undertaken in the spring from March through May, and in late summer and early fall from August to October 15. During the peak summer months and in the fall after October 15, when seeding is found to be impractical, appropriate temporary stabilization shall be applied. Permanent seeding may be undertaken during the summer if plans provide for adequate mulching and watering.
j.
All slopes steeper than 3:1 (h:v, 33.3%), as well as perimeter dikes, sediment basins or traps, and embankments must, upon completion, be immediately stabilized with sod, seed and anchored straw mulch, or other approved stabilization measures. Areas outside of the perimeter sediment control system must not be disturbed.
k.
Temporary sediment trapping devices must not be removed until permanent stabilization is established in all contributory drainage areas.
l.
All temporary erosion and sediment control measures shall be removed after final site stabilization. Disturbed soil areas resulting from the removal of temporary measures shall be permanently stabilized within 30 days of removal.
3.
A minimum of seven days prior to the start of construction, a detailed construction sequence shall be submitted to the Hopkinton Director of Land Use, Planning and Permitting by the site contractor for review and approval. The approved construction sequence shall be followed throughout the course of the construction and shall be altered only with prior review by and written approval from the Director of Land Use, Planning and Permitting.
4.
All required SWPPP Stormwater Construction Site Inspection Reports shall be submitted to the Director of Land Use, Planning and Permitting within 14 days of each inspection.
5.
An adequate stockpile of erosion control materials shall be on site at all times for emergency or routine replacement and shall include materials to repair or replace silt fences, hay bales, stone filters, berms or any other devices planned for use during construction.
6.
The disturbed area at [insert address] shall be temporarily stabilized by hydroseeding if construction of the approved [insert plan type, if any] is not commenced within 30 days of lot clearing.
7.
[insert name(s) of abutting street(s)] in the vicinity of the project shall be swept as needed throughout the construction process.
8.
Compliance with the Operations and Maintenance Plan with respect to the cleaning of stormwater management system components will require the use of equipment which tends to generate significant noise. Due to the location of the site adjacent to a residential neighborhood and the provisions of Chapter 141 of the Bylaws of the Town of Hopkinton (“Noise”), the use of such equipment shall be restricted to the hours of operation contained in said Bylaw.
18
Jennifer Burke
Saddle Hill Road Scenic Road Permit Wayne Belec Tue, Sep 19, 2017 at 1:46 PM To: Jennifer Burke Cc: John Parsons , Victor Galvani , Nate Bautz , Larry Greene
Jen-
Please find the attached electronic version of the vehicle turning movement exhibit as requested. We trust that you will find that this information addresses the comments and concerns raised by the Board last week. Paper copies are being delivered shortly.
Thank you for your attention to this supplemental information and we look forward to seeing you next Monday night to briefly discuss and close the public hearing.
-Wayne
Wayne Belec Senior Project Manager/Business Development
WDA DESIGN GROUP CIVIL ENGINEERS
LANDSCAPE ARCHITECTS
SURVEYORS
PLANNERS
CELEBRATING 20 YEARS… NEW NAME, SAME VISION.
Please note our new company name and my new email address. We’ve changed the name of our two offices to WDA Design Group. My new email address is [email protected]. Our new website is www.wda-dg.com. When you have a moment, please update our contact information and check out our new website.
From: Jennifer Burke [mailto:[email protected]] Sent: Tuesday, September 19, 2017 9:33 AM To: Wayne Belec [Quoted text hidden] [Quoted text hidden]
All email messages and attached content sent from and to this email account are public records unless qualified as an exemption under the Massachusetts Public Records Law.
Visit us online at www.hopkintonma.gov.
1066200AT EXHIBIT (2017-09-19).pdf 780K
PUBLIC HEARING OUTLINE SITE PLAN REVIEW 50-60 WEST MAIN STREET An application for Site Plan Review has been filed. The Applicant proposes to construct a 34,100 square foot addition to the existing building as part of “phase 3”. √ Principal Planner Overview of Site and Project √ Project introduction and review - Applicant √ Principal Planner Comments √ Consultant Review – BETA Group √ Other Town Departments Comments √ Add to Outline - Planning Board members and Public Detailed Discussion a. √ Traffic b. √ Building Design c. Stormwater management d. √ Parking Lot Design (1) Snow Storage e. Lighting f. Landscaping/Screening g. Utilities h. √ Construction Management Plan 8. Review by Other Boards/Committees a. Conservation Commission b. √ Design Review Board 9. Public comment/Discuss site plan standards and plan revisions to be made 10. Discuss conditions of approval with applicant 11. Public comment 12. Vote on Site Plan approval and conditions 13. Close public hearing 1. 2. 3. 4. 5. 6. 7.
§ 210-136.1 Site Plan Standards The site plan shall be designed to conform to the following Site Plan Standards: A. Site disturbance in wetland buffer zones and to slopes in excess of 25% shall be minimized. B. Unique natural and historic features shall be preserved whenever feasible. C. Tree, vegetation and soil removal shall be minimized. D. The site activities shown on the Site Plan shall be screened from view from abutting properties in residential use. Methods of screening may include solid fencing, landscaping or other proposals of the Applicant, subject to review by the Planning Board. Such screening may be located on or off-site. If located off-site, written permission of the off-site property owner shall be provided to the Board. E. All utilities shall be underground. F. Exposed storage areas, machinery, service areas, truck loading areas, utility buildings and structures and other similar uses shall be visually screened from abutting properties and those using public ways. Screening methods may consist of solid fencing, landscaping or similar proposals submitted by the Applicant, subject to review by the Planning Board. G. The site plan shall show measures to reduce and abate noise and odors generated from the site that will impact surrounding properties. H. The site plan shall comply with all zoning requirements. I. The site plan shall maximize the convenience and safety of vehicular and pedestrian movement within the site and to and from adjacent public ways. If supporting documentation, such as a traffic or parking study, submitted to the Planning Board indicates that the vehicular and pedestrian traffic movement depicted on the site plan and proposed in the application will have a significant negative impact or impacts on the site or within the adjacent ways, such impacts shall be mitigated by the Applicant. J. Parking areas shall be designed so that they are safe and convenient and do not detract from the use and enjoyment of proposed structures. Parking areas shall be designed to facilitate safe pedestrian access to the structures and other on-site facilities. K. The site plan shall minimize the number of curb cuts on public ways. L. Driveways shall be designed to ensure safe sight distances at interior and exterior intersections and along driveways, in accordance with applicable AASHTO requirements. M. Sidewalks shall be provided along the entire frontage of the subject property along existing public ways. The Planning Board may approve alternative provisions or waive the requirements of this Standard in situations where sidewalk construction or use is not feasible or practical. N. Levels of illumination shall be provided as follows: [Amended 5-6-2015 ATM. Art. 36] (1) No property may have exterior lighting that exceeds the average illumination level recommended by the Illuminating Engineering Society of North America for such use as set forth in “Lighting Facilities for Parking Facilities,” Illuminating Engineering Society, 2014 and “The Lighting Handbook,” 10 th Ed., Illuminating Engineering Society, 2011. (2) For pole mounted lights in parking and driveway areas, the height of the light source shall not exceed 15 feet, which shall be measured from the ground at the base of the pole to the bottom of the fixture. (3) Pedestrian area lighting shall utilize fully shielded fixtures, and the height of light source shall not exceed 12 feet, measured from the ground at the base of the pole to the bottom of the fixture. (4) No exterior lighting may interfere with the safe movement of motor vehicles on public ways or private ways open to the public. (5) Mercury vapor lamps shall be prohibited. (6) Uplighting shall be permitted only when used in one of the following manners: (a) To light a primary entrance, when the fixture or lamp is wall-mounted under an architectural element (e.g., roofs over walkways, entries or overhanging, nontranslucent eaves) so that the uplighting is fully captured; (b) To light local, state or national flags; or (c) To highlight or illuminate a building facade or landscaping, or to highlight or illuminate statues or monuments. (7) Floodlighting shall be permitted only if a fully shielded fixture is utilized and no lighting will fall onto the property of others. (8) Safety and security lighting shall use motion sensors, photocells, or photocells or timers to control duration of nighttime illumination.
(9) Exterior lighting of recreation facilities shall utilize fully shielded fixtures and, except as authorized by Special Permit or Site Plan Approval, shall be turned off by 10:00 p.m. or at the conclusion of an activity begun before 10:00 p.m.; provided, however, that in any event the exterior lighting shall be turned off by midnight. (10) Blinking, flashing, moving, revolving and flickering lights, as well as lighting that changes intensity or color shall be prohibited except for lighting for public safety or traffic control and lighting required by the U.S. Federal Aviation Administration for air traffic control and warning purposes. (11) Notwithstanding any provisions of this subsection to the contrary, sidewalks that run along the perimeter of a site and are in a public right of way or on abutting property may be illuminated, and illumination may spill onto abutting non-residential property if requested in writing by the abutting property owner.
O. P.
Q. R.
Exterior lighting that does not conform to the provisions of this subsection may be allowed by special permit from the Planning Board if the Planning Board finds that such exterior lighting will be consistent with the Purposes of this Article, or that there are other demonstrable community, health, safety or welfare benefits that will be served by the exterior lighting. No special permit may be granted pursuant to this subsection unless the Planning Board determines that the proposed exterior lighting is appropriate for the size and use of the property, any buildings thereon, and the neighborhood setting. Adequate access shall be provided to each structure for emergency vehicles and personnel. The site plan shall conform to applicable Massachusetts Department of Environmental Protection Stormwater Management Regulations. The site plan shall show adequate measures to prevent pollution of surface water and groundwater, to minimize erosion and sedimentation and to prevent changes in the potential for flooding. Stormwater management facilities shall be designed so that neighboring properties, public ways and public storm drainage systems will not be adversely impacted. Mechanical equipment or other utility hardware on the roof, grounds or buildings shall be screened from view from the ground. All dumpsters shall be screened from public view.
J.D. MARQUEDANT & ASSOCIATES INC. Land Surveying 6 Walcott Street Hopkinton MA 01748 Phone: 508-435-4145 Fax: 508-435-0157 September 7, 2017 Ms. Jennifer Burke, Principal Planner Town of Hopkinton Planning Board 18 Main Street Hopkinton MA 01748 Re: "The Lofts" at Golden Pond 50 West Main Street Dear Jennifer: I am in receipt of a letter from BETA Group Inc. dated July 24, 2017 regarding project designs for the Golden Pond Medical Care Facility Phase 3 addition. Based on concerns raised in that letter, project designs have been revised. I offer the following summary of the project design revisions:
Article VII - Rural Business (BR) District: Z1: Radner Design Associates has been retained to prepare Landscape plans for the proposed addition. The plans will be forwarded to your office as soon as they become available. Article XII - Water Resources Protection Overlay District: WR1. Soil testing was recently completed in several areas on the project site to assess the soil composition and estimated season high ground water levels. The stormwater management system has been revised based on the soil testing information. A closed drainage system of catch basins, manholes and piping will convey stormwater to a proposed forebay and retention basin at the northerly end of the project site. The forebay has an outlet structure which will release stormwater to the retention basin. Both the forebay and basin have been designed with a four foot or greater offset to estimated seasonal high groundwater. The existing drainage system will continue to carry the foundation drain flow only. The proposed stormwater management system has been designed to meet the DEP Stormwater Management Regulations. The plans have been revised to include elements of the stormwater management system and the supporting calculations have been updated to reflect the changes to project designs. (see sheets C-2 thru C-5 and C-8). Article XX: Site Plan Review: SP1. Photogrammetric analysis was completed as part of the previous submission for the site. Additional walk lighting and building mounted lighting information has been included with the revised designs. (see sheet C-7).
SP4: The designs have been revised to relocate the existing sanitary sewer force main should there be a conflict with the proposed building footing or foundation system and a typical trench section construction detail is included in the revised designs. (see sheets C-4 and C-6). SP5: The principals at The Golden Pond Resident Care Corp. are the owners of the parcel at 62 West Main Street and have control over the parcel. A lease agreement between the two parties has been developed and has been submitted to the Town of Hopkinton Planning Board for review Stormwater Management:
SW6: Riprap Pad calculations have been provided and are contained within the attached stormwater report SW11: Soil test data from testing conducted August 9, 2017 has been included in the revised designs. (see Sheet C-4) SW22: Access has been provided along the westerly property line to the basin and forebay. Construction materials will be organized and relocated if necessary to insure long term access for inspection and maintenance activities
Please contact me regarding any concerns you may have. Thank you for your attention to this matter. Sincerely, Joseph P. Marquedant J.D. Marquedant & Associates Inc. Cc: Kerry Kunst
September 19, 2017 Town of Hopkinton Planning Board Land Use, Planning, and Permitting Department 18 Main Street Hopkinton, MA 01748 Attn.: Ms. Jennifer Burke, Principal Planner Re:
Site Plan Review Update for The Golden Pond Residential Care Corporation – Hopkinton, MA
Dear Ms. Burke: BETA Group, Inc. (BETA) reviewed supplemental/revised documents for the Application for Approval of Site Plan Review for the The Golden Pond Resident Care Corporation. This letter is provided to update BETA’s findings, comments and recommendations. BASIS OF REVIEW The following supplemental/revised documents were received by BETA and formed the basis of the review: · · · ·
Response to comments letter to the Planning Board dated September 7, 2017 from J.D. Marquedant & Associates Inc., Hopkinton, MA Letter to the Hopkinton DPW requesting approval of water usage for the project dated July 17, 2017 from J.D. Marquedant & Associates Inc. Site Plans (9 sheets) entitled “The Lofts at Golden Pond” dated May 15, 2017 revised to September 7, 2017, prepared by J.D Marquedant & Associates Inc. and others Stormwater Report and Drainage Calculations Golden Pond Medical Care Facility 50 West Main Street in Hopkinton MA dated May 23, 2017, revised to September 5, 2017 prepared by Mark Piermarini
COMPILED REVIEW LETTER KEY BETA reviewed this project previously and provided review comments in letters to the Board dated June 26, 2017 and July 24, 2017 (original comments in italics), J.D. Marquedant & Associates Inc. (JDMAII) provided responses (responses in standard text) and BETA has provided comments on the status of each (status in bold italics). INTRODUCTION The site is currently developed with an existing 103,763 square foot (sq. ft.) medical care facility, site access drive, parking areas, utilities and stormwater management system.
BETA GROUP, INC. nd 315 Norwood Park South, 2 Floor, Norwood, MA 02062 P: 781.255.1982 | F: 781.255.1974 | W: www.BETA-Inc.com
Town of Hopkinton September 19, 2017 Page 2 of 9 The submitted documents indicate a proposed 34,100± sq. ft. building addition that would add 54 beds to the facility. The proposed use, health services facility, is permitted within the district. No changes to the site access or parking facilities are proposed. The project proposes work within wetland resource areas that requires conforming to the Massachusetts Wetlands Protection Act and Hopkinton Wetlands Protection Bylaw and obtaining an Order of Conditions from the Hopkinton Conservation Commission. The project is proposing stormwater management system expansion which will need to comply with the MassDEP Stormwater Management Standards and the Hopkinton Stormwater Management Bylaw and regulations. ZONING Article VII – Rural Business (BR) District The project is located on a previously developed lot and work proposed is part of Phase 3 of the Golden Pond Continuing Care Retirement Community. The project previously received approval through a Special Permit by the Town of Hopkinton Board of Appeals, with a decision recorded on November 18, 2009 for the following uses: “Continuing Care Retirement Community,” “Special Care Residences,” “Acute Care Services,” and “Rehabilitation Clinic.” The project reviewed in 2009 authorized a Special Permit for a phase project in two stages: Phase 2 and Phase 3. The lot is located within the Rural Business (BR) District Zone. The proposed building expansion use will encompass the previously approved uses for the facility and no change is anticipated. These uses (§21024.A.(5): Continuing Care Retirement Community Facilities/Assisted Living Facilities/Nursing Home Facilities) are allowed through a Special Permit. With the addition of the proposed building expansion the project continues to meet the requirements for minimum lot area, maximum lot coverage, street line setback, side and rear yard setbacks, and height. Loading zone is provided at the side of the building. Landscaping has been shown on provided plans and the landscaping along the street frontage is not anticipated to be modified. Z1.
Landscape plans, dated 2011, show proposed landscaping for building expansion and work along West Main Street. Provide plans showing any plants proposed for current proposed work and how any screening will be provided adjacent to the residential district. BETA2: No response or additional information provided – issue remains outstanding. JDMAI2: Radner Design Associates has been retained to prepare Landscape plans for the proposed addition. The plans will be forwarded to your office as soon as they become available. BETA3: Landscape plans not provided – issue remains outstanding
Article XII – Water Resources Protection Overlay District The site is also located within the Water Resource Overlay District (WRPOD-1). The proposed continued uses are permitted within the overlay district. The building expansion is proposed to increase the impervious areas to the site by 10,000± sq. ft. of new pavement and roof surfaces. The Applicant is providing recharge through the expansion of the existing retention basin. A sediment forebay is proposed to be installed upstream of the retention basin. WR1.
Wet basins and constructed stormwater wetlands are not BMPs that provide groundwater recharge (MassDEP Stormwater Standards, Volume 2, Chapter 1, Page 36). Provide MassDEP approved recharge BMP to satisfy providing groundwater recharge. See comment SW9. JDMAI1: The basin is a retention basin which utilizes recharge. The calculations have been revised to use an "A" soil type.
Town of Hopkinton September 19, 2017 Page 3 of 9 Copies of the revised calculations are attached to this letter. BETA2: During recent site visit, water was observed up to invert elevation of outlet which indicates that this BMP functions as a constructed stormwater wetland. Provide an infiltration BMP as required – issue remains outstanding. JDMAI2: Soil testing was recently completed in several areas on the project site to assess the soil composition and estimated season high ground water levels. The stormwater management system has been revised based on the soil testing information. A closed drainage system of catch basins, manholes and piping will convey stormwater to a proposed forebay and retention basin at the northerly end of the project site. The forebay has an outlet structure which will release stormwater to the retention basin. Both the forebay and basin have been designed with a four foot or greater offset to estimated seasonal high groundwater. The existing drainage system will continue to carry the foundation drain flow only. The proposed stormwater management system has been designed to meet the DEP Stormwater Management Regulations. The plans have been revised to include elements of the stormwater management system and the supporting calculations have been updated to reflect the changes to project designs. (see sheets C-2 thru C-5 and C-8). BETA3: Additional soil test pit provided – issue resolved. Article XVIII - Supplementary Regulations (as applicable) §210-124 Off Street Parking There are approximately 127± existing parking spaces at the site, 8 of which are handicapped accessible. The project is proposing no change to the number of parking spaces based on the proposed building spaces. Section 210-124.B.(1) states that Continuing Care Retirement Facility/Assisted Living/Nursing Home Facilities require 1 parking space for every 3 beds, plus 1 bed for each employee on the largest shift. Decision dated December 2009 allowed for the variance relief of a total of 14 parking spaces (8 for Phase 2 and 6 for Phase 3). Based on the proposed beds and employees resulting from the building expansion and taking into account the prior relief granted, 115 spaces are required at the site. Minimum number of handicapped accessible spaces is 5 which are met at the site. Z2.
Revise parking summary on Page 3 to reflect the parking space requirement relief granted by the Board. JDMAI1: The parking summary has been revised to reflect the relief granted by the Board of Appeals (see sheet C-3). BETA2: Parking summary revised – issue resolved.
Article XX – Site Plan Review §210-136.1 Site Plan Standards Work includes the new building, minor site work, utility modifications, and stormwater management features. There are no recorded historical features located at the site. Proposed utilities are shown underground. No new curb cuts expected for the site. New sight lighting is provided along the northern edge of the building but no photogrammetric analysis has been conducted. Noise and odors are expected to be similar to that of the existing buildings at the site. The Site Plan complies with Zoning except as noted above. See appropriate sections for comments on Zoning and Stormwater Management. SP1.
Provide photogrammetric analysis of proposed building to analyze spillage onto adjacent properties. BETA2: No response or additional information provided – issue remains outstanding. JDMAII: Photogrammetric analysis was completed as part of the previous submission for the site. Additional walk lighting and building mounted lighting information has been included with the revised designs. (see sheet C-7). BETA3: No photogrammetric analysis has been provided BETA defers to the Board on this issue.
Town of Hopkinton September 19, 2017 Page 4 of 9 SP2.
Town of Hopkinton Police and Fire Departments should confirm that there is adequate access around buildings and safety around parking lot during construction as shown on Plan C-9 Construction Summary Plan of Land (§210-136.O). BETA2: No response or additional information provided – issue remains outstanding. BETA3: No response or additional information provided – issue remains outstanding.
SP3.
Information has been provided showing approval for sewage increase from Town of Hopkinton Water and Sewer Department. Provide similar information that sufficient fire and potable water supplies are available for the building expansion. JDMAI1: Sufficient municipal water is available for the project. A formal request has been made to the Department of Public works regarding potable water. A copy of the request is attached to this letter. BETA2: Documentation with Department of Public Works provided. BETA defers to the forthcoming response of the Department of Public Works.
SP4.
Sewer forcemain is shown to be approximately 2 feet away from the proposed building corner. It is likely this will be impacted during construction. Provide plan to protect or relocate forcemain or replacement in case of disturbance. JDMAI1: The designs have been revised to relocate the existing sanitary sewer force main should there be a conflict with the proposed building footing or foundation system. (see sheet C-4). BETA2: Sewer forcemain shown to be relocated. Provide typical trench section detail for sewer forcemain. JDMAI2: The designs have been revised to relocate the existing sanitary sewer force main should there be a conflict with the proposed building footing or foundation system and a typical trench section construction detail is included in the revised designs. (see sheets C-4 and C-6). BETA3: Trench detail provided – issue resolved.
SP5.
About 15% of the existing parking spaces will be impacted by construction activities. Identify if this deficit will impact operations at the facility and recommend providing additional parking as needed. In addition, identify location of proposed construction trailer referenced in the Construction Management Plan to verify additional impact to parking spaces. JDMAI1: The location of the proposed construction trailer has been added to the revised design plans (see sheet C-9). It is anticipated that the twenty three (23) spaces associated with the Phase 3 addition will allow for site parking during the construction era for the addition. The twenty three spaces will not be necessary for staff and residents use until the construction is complete and will be available for use. BETA2: Location of trailer added to plans. Temporary parking area shown on plans on adjacent 62 West Main Street lot. Provide documentation indicating permission to use area for parking. JDMAI2: The principals at The Golden Pond Resident Care Corp. are the owners of the parcel at 62 West Main Street and have control over the parcel. A lease agreement between the two parties has been developed and has been submitted to the Town of Hopkinton Planning Board for review. BETA3: Explanation provided – issue resolved.
SP6.
Provide details of proposed retaining wall south of the new building expansion. BETA2: Details not included in resubmission – issue remains outstanding. BETA3: Details not included in the resubmission – issue remains outstanding.
TRAFFIC ASSESSMENT REVIEW Access to the site will be through the existing driveways, no new curb cuts are proposed for the site. Observed site distances are adequate. The new expansion of 54 beds will reportedly generate an additional 220 weekday daily trips, with an additional 10 weekday AM Peak Hour trips and 16 and weekday PM Peak Hour trips.
Town of Hopkinton September 19, 2017 Page 5 of 9 STORMWATER MANAGEMENT BETA visited the site to confirm limits of the drainage areas at the site, characteristics, and existing surface conditions. The proposed building is located north and west of the existing building location. The area is currently a grass lawn with concrete walkways adjacent to this area. The rest of the site has been developed with existing care facility buildings, parking, driveway, grassed open space, an existing pond, and landscaped features. NRCS classifications for soils (Web Soil Survey Version 16, September 14, 2016) indicate the site is majority Narragansett silt loam with a hydrologic soil group rating of A (high infiltration potential) Portions northeast of the site adjacent to the existing stormwater basin contains Ridgebury fine sandy loam with a HSG of D (minimal infiltration potential). BETA also notes that there was standing water observed in the basin which may indicate the presence of high groundwater, poor infiltration or that maintenance may be necessary. The design proposes to capture, treat, and infiltrate stormwater runoff from the proposed impervious areas via a roof drains, route flow to a new sediment forebay, and into an expanded extended detention / retention basin. Overflow is shown to be provided by the installation of both a new 15 and 12 inch HDPE over flow pipes. Riprap emergency spillway is proposed to be extended. A Stormwater Management Permit (SMP) conforming to the Town of Hopkinton Stormwater Regulations is required from the Planning Board based on the proposed construction activity disturbing more than one area of land as shown on the provided plans. In addition, the project is part of a master plan that will disturb more than one acre (§172-2.B(1)). A Stormwater Management Plan is required as part of the permit submission and the applicant has included a Stormwater Report and Drainage Calculations. SW1.
Provide Contact Information and Tax Reference Parcel identification number of the properties affected in the Drainage Report and Stormwater Management Plan (Appendix B.1). BETA2: Information not provided – issue remains outstanding. BETA3: Contact information provided in the Inspection and Maintenance Plan of the Drainage Report and Stormwater Management Plan. Tax Reference Parcel information provided on the design plans – issue resolved.
SW2.
Provide locus map in the Drainage Report and Stormwater Management Plan (Appendix B.3). JDMAI1: A locus map is contained within the Stormwater Report and calculations in the "Soils" section and the "FEMA" section. BETA2: Map provided in the Soils section and FEMA section – issue resolved.
SW3.
Provide delineation of 100-year flood plain. Available FEMA mapping is in conflict with the boundary shown on the plans (e.g. FEMA shows Zone A around ice house dam while plans do not show this / illegible) (Appendix B.12). JDMAI1: The delineation of the 100-year flood plain from available FEMA mapping has been added to the revised design plans. (see sheet C-2). BETA2: Limit added to plans – issue resolved.
SW4.
Provide drainage area maps for pre- and post-development conditions (Appendix B.15). JDMAI1: The Pre and Post development subcatchment maps have been provided and are attached to this letter. BETA2: Watershed maps provided – issue resolved.
SW5.
Provide additional spot grades for forebay top and bottom and all spillways part of the stormwater management system. JDMAI1: Additional spot grades at locations around the stormwater mitigation elements. Additional notes regarding the forebay and basin elevations have been added to the revised design plans. (see sheets C-4 and C-5). BETA2: Additional proposed grading added to plans – issue resolved. BETA3: Revised forebay and detention basin grading is very difficult to follow, provide detail of each at a smaller scale (1” = 10’) for review.
Town of Hopkinton September 19, 2017 Page 6 of 9 Massachusetts Stormwater Management Standards: The project is subject to the Stormwater Management Standards (Stormwater Regulations (SWR) 7.0). The following are the 10 standards and relative compliance provided by the submitted documentation. No untreated stormwater (Standard Number 1): No new stormwater conveyances (e.g., outfalls) may discharge untreated stormwater directly to or cause erosion in wetlands or waters of the Commonwealth. The project does not propose untreated stormwater discharges to wetlands. Runoff from new impervious areas are proposed to be routed to the reconstructed retention basin and discharged through three outlet pipes. SW6.
Provide calculations for sizing riprap pad outlets associated with the new drainage pipes (12” and 15” HDPE) adjacent to the existing wetland. JDMAI1: Riprap Pad calculations have been provided and are contained within the attached stormwater report. BETA2: Calculations not included – issue remains outstanding. JDMAII: Riprap Pad calculations have been provided and are contained within the attached stormwater report. BETA3: Riprap pad calculations provided – issue resolved.
Post-development peak discharge rates (Standard Number 2): Stormwater management systems must be designed so that post-development peak discharge rates do not exceed pre-development peak discharge rates. Calculations provided indicate the project will not increase in peak runoff flow for the 2, 10, 25, and 100 year storm events. In addition, data provided shows runoff volumes decreasing between pre- and postdevelopment conditions. SW7.
NRCS Web Soil Survey (Version 16, September 14, 2016) indicates that majority of project site is within HSG A soils. Revise modeling to include A soils in analysis. JDMAI1: The calculations have been revised to utilize an A soil type. BETA2: Proposed modeling conditions not updated – issue remains outstanding. BETA3: Soils type updated in the modeling – issue resolved.
SW8.
HydroCAD model indicates oscillating condition for the existing basin (outlet flow is higher than inlet flow) for the 100 year storm event. Adjust model to eliminate this condition. JDMAI1: The stormwater drainage calculations have been revised accordingly. BETA2: Proposed modeling conditions not updated – issue remains outstanding. BETA3: The following need to be address for the new design: a. Existing drain system mapping is incomplete; provide information for interior courtyard area, Phase 1 roof drains, DMH at southeast building corner…. b. Add to existing model the catchment area and routing of flow through the small pond where proposed forebay is located and verify that oscillations in existing basin are eliminated. c. Provide detail and explanation of “pipe through manhole”. d. Check pipe conflict of drain pipes crossing near DMH 4A e. Update pre development model to subdivide catchment area 4A and model pond near dumpster f.
SW9.
Update post development model to include new 24 inch bypass pipe and provide explanation as to the size.
Proposed Detention Basin (Pond 7P) is modeled to include exfiltration. Based on observing standing water in the basin, it may not be empty between storms reducing storage area and limiting exfiltration. Review model and update as necessary after gathering additional soil test data. JDMAI1: The bottom of the basin may need to be scoured out and cleaned from sediment buildup over time.
Town of Hopkinton September 19, 2017 Page 7 of 9 Any sediment build up will inhibit exfiltration. BETA2: Provided test pit data shows soil to be sandy loam material, a high HSG B material. Notes shall be placed on the plans outlining these measures to restore infiltration capacity of basin – issue remains outstanding. BETA3: No explanation for observations of standing water was provided. Revised design shows pipe to bypass basin. SW10. Peak elevation of Pond 7P: Proposed detention basin is elevation 368.20 whereas top of system modeled is elevation 369. Revise model to include 1 foot of freeboard and plans to ensure top of basin is minimum elevation 369.2 around. Complete similar model modifications for existing condition. JDMAI1: The drainage calculations will be revised accordingly. BETA2: Proposed modeling conditions not updated – issue remains outstanding. BETA3: One foot of freeboard provided around basin – issue resolved. Recharge to groundwater (Standard Number 3): Loss of annual recharge to groundwater should be minimized through the use of infiltration measures to maximum extent practicable. Recharge is proposed to be provided utilizing the regraded detention/retention basin. NRCS Web Soil Survey mapping shows the site comprised of Narragansett silt loam (HSG A) and Ridgebury fine sandy loam (HSG D). No test pits have been conducted and no information has been provided detailing soil type and estimated seasonal high groundwater. However, hydrologic modeling and recharge calculations are provided using an assumption that the soils are rated in HSG B. SW11. Provide soil test data within limits of stormwater BMP to identify seasonal high groundwater elevations and to confirm soil classification. JDMAI1: Soil test data from September 2012 and July 2017 has been added to the revised design plans. (see Sheet C-4). BETA2: Test pit information from 2012 and 2017 have been provided. No. 1 and No. 2 were performed on September 7, 2012 and TP-1 and TP-2 were performed on July 11, 2017. Existing elevations were not provided with No. 1 and No. 2 to determine elevation of seasonal high groundwater. TP-1 was performed at elevation 272 and bottom of test was at 262. Estimated seasonal high groundwater is elevation 266. TP-2 was performed at elevation 275 and bottom of test was at 267. No mottles were observed in this test pit and it is noted that the bottom of the proposed basin is elevation 265.3, below the bottom of the performed testing. MassDEP requires a minimum of 2 feet of separation between the bottom of an infiltration system and seasonal high groundwater – issue remains outstanding. JDMAII: Soil test data from testing conducted August 9, 2017 has been included in the revised designs. (see Sheet C4) BETA3: Test pit data provided issue resolved. SW12. Include provisions for protecting the infiltrative capacity of soils in infiltration areas during construction. Include the construction management area which is located on pervious pavement. JDMAI1: Construction equipment will be stored temporarily on paved surfaces. No soil stockpiles will be allowed in the area of the existing porous pavement surface. BETA2: Place note on plans specifying these provisions – issue remains outstanding. JDMAII: BETA3: Notes not shown on plans – issue remains outstanding. 80% TSS Removal (Standard Number 4): For new development, stormwater management systems must be designed to remove 80% of the annual load of Total Suspended Solids. Stormwater runoff from the proposed project area is intended to infiltrate into the proposed basin. TSS removal is to be achieved through the use of sediment forebay and infiltration basin. Long term pollution prevention measures have been included in the Operation and Maintenance Plan. SW13. Provide calculations to show the proposed sediment forebay has been sized to hold at a minimum, 0.1-inch/impervious acre. JDMAI1: Water Quality Calculations have been provided for 1/2 inch of runoff over the impervious area that runs to the existing basin. The area of the site being
Town of Hopkinton September 19, 2017 Page 8 of 9 redeveloped has an increase of 0.20 acres of impervious area which is entirely roof runoff, "clean runoff" according the Massachusetts Department of Environmental Protection (DEP) Stormwater Regulations. The remainder of the site is not being redeveloped and therefore is not included in this calculation. BETA2: Provide sediment forebay sizing calculations for the parking lot pavement areas – issue remains outstanding. JDMAII: BETA3: Forebay sizing calculations provided– issue resolved. Higher Potential Pollutant Loads (Standard Number 5): Stormwater discharges from Land Uses with Higher Potential Pollutant Loads require the use of specific stormwater management BMPs. This project documentation does not propose Land Uses with Higher Potential Pollutant Loads – not applicable. Critical Areas (Standard Number 6): Stormwater discharges to critical areas must utilize certain stormwater management BMPs approved for critical areas. This project does not discharge stormwater to critical areas – not applicable. Redevelopment (Standard Number 7): Redevelopment of previously developed sites must meet the Stormwater Management Standards to the maximum extent practicable. The site is considered new development because of the proposed new impervious areas associated with the building expansion. Construction Period Erosion and Sediment Controls (Standard Number 8): Erosion and sediment controls must be implemented to prevent impacts during construction or land disturbance activities. As shown, the project site is greater than 1 acre in area and land disturbance activities will require a Notice of Intent with EPA. A Stormwater Pollution Prevention Plan (SWPPP) is required to be submitted as part of MassDEP Stormwater Standards. Per the Town of Hopkinton Stormwater Regulations, an Erosion and Sediment Control Plan is required to be submitted. Plans include locations of erosion control barriers. SW14. Provide anticipated location(s) of soil/material stockpile area on plans and include erosion and sedimentation control measures to limit transport of materials. JDMAI1: An anticipated location for temporary soil stockpiling has been added to the revised design plans. (see sheet C-9) BETA2: Temporary soil stockpile area identified on plans – issue resolved. SW15. Site appears to disturb more than one acre of land. Provide figure and calculations if proposed work is not anticipated to disturb more than one acre. JDMAI1: Site redevelopment activities total less than 1 acre. BETA2: Provided project is not expanded further than shown, erosion and sediment control measures for the site are adequate – issue dismissed. SW16. Provide draft SWPPP / Erosion and Sediment Control Plan in accordance with requirements in Appendix C (1-5). JDMAI1: Site redevelopment activities total less than 1 acre. BETA2: Provided project is not expanded further than shown, erosion and sediment control measures for the site are adequate – issue dismissed. SW17. Provide catch basin inlet protection for existing catch basins on the site and include detail. BETA2: Detail provided – issue resolved. SW18. Recommend using stake compost filter sock or straw wattle in lieu of staked hay bales. BETA2: To reduce invasive species migration, recommend using compost filter sock or straw wattle – issue remains outstanding. BETA3: BETA defers to the Conservation Commission on this issue. Operations/maintenance plan (Standard Number 9): A long-Term Operation and Maintenance Plan shall be developed and implemented to ensure that stormwater management systems function as designed. Operation and Maintenance with basic tasks was included in the Stormwater Report and Drainage Calculations submission.
Town of Hopkinton September 19, 2017 Page 9 of 9 SW19. Provide and or update standalone Long Term Operation and Maintenance Plan which includes the requirements outlined in Appendix D 1-3. JDMAI1: An Operation and Maintenance Plan (O&M) and protocols are contained within the Stormwater Report. Prior to the completion of the site designs the O&M plan will separated out to function as a standalone document. BETA2: Include the following information as required in Appendix D 1-3 in the Operation and Maintenance Plan: provisions for the planning board to enter the property at reasonable times for inspection, signature of the owners – issue remains outstanding. JDMAII: BETA3: Provisions for the planning board to enter and signatures of owners not provided – recommend including these as conditions. SW20. Include map (preferably 11” x 17”) with the Long-Term Operation and Maintenance Plan (LTOMP) to identify and highlight BMP locations to be maintained and locations of snow storage. JDMAI1: An 11"x17" drainage plan has been provided and is attached to this letter. BETA2: Location of snow storage areas should be identified on plan – issue remains outstanding. BETA3: Issue not addressed – issue remains outstanding. SW21. Provide a description and delineation of public safety measures. JDMAI1: Access has been provided along the westerly property line to the basin and forebay. Construction materials will be organized and relocated if necessary to insure long term access for inspection and maintenance activities. BETA2: Safety measures not provided. Given the existing site features (dumpster area, plantings, basin) it is not clear how vehicles will access the basin. Provide figure showing proposed routes vehicle can take to the basin – issue remains outstanding. JDMAII: BETA3: with the expanded forebay, vehicles are less likely to be able to access stormwater basin from the east. Gate and plantings exist to the west of the dumpster area. Figure showing proposed routes a vehicle can take to access the basin not provided – issue remains outstanding. SW22. Provide and maintain vehicular access to stormwater basin for maintenance purposes. BETA2: See SW21. JDMAII: Access has been provided along the westerly property line to the basin and forebay. Construction materials will be organized and relocated if necessary to insure long term access for inspection and maintenance activities. BETA3: See SW21. Illicit Discharges (Standard Number 10): All illicit discharges to the stormwater management systems are prohibited. An Illicit Discharge Compliance Statement was not included with the submission. SW23. Provide a signed illicit discharge compliance statement. JDMAI1: A signed and sealed Illicit Discharge statement was included in the Stormwater Checklist section of the Stormwater Report. BETA2: Signed statement not included in submission – issue remains outstanding. BETA3: Signature provided – issue resolved. If we can be of any further assistance regarding this matter, please contact us at our office. Very truly yours, BETA Group, Inc.
Philip F Paradis, Jr., PE Associate
Christopher Luppino, PE Civil Engineer
O:\5700s\5700 - Hopkinton - Golden Pond Residential\Engineering\Reports\Golden Pond Residential Peer Review 9-14-17.docx
PUBLIC HEARING OUTLINE SOLAR SPECIAL PERMIT/STORMWATER MANAGEMENT PERMIT 147 LUMBER STREET An application for a solar special permit and a stormwater management permit application have both been filed for this address. The project proposes a 2.9 MW installation on approximately 11.4 acres of the total 41.5 acres. 1. 2. 3. 4. 5. 6. 7.
Principal Planner Overview of Site and Project Project introduction and review - Applicant Principal Planner Comments Consultant Review – BETA Group Other Town Departments Comments Add to Outline - Planning Board members and Public Detailed Discussion a. Site Layout b. Driveway Width c. Lighting d. Screening e. Array Size f. Underground Utilities g. Stormwater Management 8. Review by Other Boards a. Conservation Commission 9. Public comment/Discuss special permit/stormwater management standards and plan revisions to be made 10. Discuss conditions of approval with applicant 11. Public comment 12. Vote on Special Permit approval and conditions 13. Vote of Stormwater Management Permit 14. Close Public Hearing
APPLICATION FOR SPECIAL PERMIT
CEC Solar #1206, LLC 147 Lumber Street Hopkinton, Massachusetts
Prepared for: CEC Solar #1206, LLC c/o Clean Energy Collective 146 West Boylston Drive, 3rd Floor Worcester, MA, 01606
Presented by:
BEALS+THOMAS BEALS AND THOMAS, INC. Reservoir Corporate Center 144 Turnpike Road Southborough, MA 01772-2104
Submitted in Compliance with the Hopkinton Zoning Bylaws. August 24, 2017
283600PT001
BEALS+THOMAS BEALS AND THOMAS, INC. Reservoir Corporate Center 144 Turnpike Road Southborough, MA 01772-2104
T 508.366.0560 F 508.366.4391 www.bealsandthomas.com Regional Office: Plymouth, MA
August 24, 2017 Mr. John Ferrari, Chair Hopkinton Planning Board c/o Hopkinton Town Clerk 18 Main Street Hopkinton, Massachusetts
Via:
Hand Delivery
Reference:
Application for Special Permit Lumber Street Solar 147 Lumber Street Hopkinton, Massachusetts B+T Project No. 2836.00
Dear Chairperson Ferrari and Members of the Board: On behalf of the applicant, CEC Solar #1206, LLC, c/o Clean Energy Collective, Beals and Thomas, Inc. respectfully submits this application for Special Permit for the installation and operation of a Commercial Solar Photovoltaic Installation (Array) at 147 Lumber Street in Hopkinton, Massachusetts. This filing is submitted in accordance with the Hopkinton Zoning Bylaws (the Bylaws), specifically Article XXXI, Commercial Solar Photovoltaic Installations. The parcels on which the Array is proposed are R29-15-0 (147 Lumber Street) and R30-1-A (Off Alexander Street). The Project will consist of a 2.9 megawatt (MW) (DC) solar facility on an 11.4-acre site, composed of two parcels under common ownership totaling ±41.5 acres. The proposed development will connect to Lumber Street via an existing driveway, located at the western boundary of the Property, which will be extended to provide access to the Array. As required, enclosed are nine (9) total copies, including the original, of the Special Permit submission package as well as an electronic version of the submission on a flash drive. The following information is included for your review: Section 1.0: Section 2.0: Section 3.0: Section 4.0: Section 5.0:
Special Permit Forms; Project Narrative; Abutter Information; Stormwater Management Information; and Plans.
Mr. John Ferrari, Chair Hopkinton Planning Board August 24, 2017 Page 2
We understand that the Planning Board will provide newspaper notice of the public hearing regarding this Application, for which the Applicant will be billed directly. We understand that the Planning Board will send, via U.S. mail, notice to the abutters, with address labels, envelopes, and first-class postage provided by B+T. Enclosed is a check payable to the Town of Hopkinton in the amount of $2,000.00 for the appropriate application fee, which includes $500 for the Special Permit Application and $1,500 for the Consultant Review Fee. The Project has been designed in compliance with Article XXXI, Commercial Solar Photovoltaic Installation. We understand that specific items including the determination of an owner/installer, financial surety and liability insurance will be determined in coordination with the Town Planner upon a final contract with an owner/installer and will be conditioned as part of the approval. Thank you for your consideration of this Application. We look forward to meeting with the Planning Board at the next available public hearing. Should you have any questions regarding this Application or require additional information, please contact us at (508) 366-0560. Very truly yours, BEALS AND THOMAS, INC.
John P. Gelcich, AICP Senior Planner Enclosures cc:
Hopkinton Town Clerk (1 copy via hand delivery) Clean Energy Collective (1 copy via US Mail)
JPG/jyb/283600PT001
John E. Bensley, PE Principal
Questions & Answers
Ground-‐Mounted Solar Photovoltaic Systems
June 2015
Westford Solar Park, photo courtesy of EEA
Massachusetts Department of Energy Resources Massachusetts Department of Environmental Protection Massachusetts Clean Energy Center
Table of Contents Background……………………………………………………………………………………………………….3 Hazardous Materials………………………………………………………………………………………...5 End-‐of-‐Life/Decommissioning…………………………………………………………………………..7 Ambient Temperature (“Heat Island”)……………………………………………………………...9 Electric and Magnetic Fields (EMF)………………………………………………………………....10 Property Values…………………………………………………………………………….……………..….13 Public Safety (including fires)…………………………………………………………………………..14 Historic Preservation……………………………………………………………………………………….16 Noise……………………………………………………………………………………………………………….18 Water-‐Related Impacts……………………………………………………………………………………20 Glare……………………………………………………………………………………………………………….22 Endangered Species and Natural Heritage………………………………………………………23
2
Background Encouraging increased use of solar photovoltaic (PV) technology, which converts sunlight directly into electricity, is a key priority for state clean energy efforts. The environmental benefits of solar PV abound. Unlike conventional fossil fuel power generation (such as coal, gas and oil), generating electricity with ground-‐mounted solar PV involves no moving parts, uses no water, and produces no direct emissions of climate-‐warming greenhouse gases. Solar PV environmental and energy benefits, combined with strong incentives available for solar projects, have significantly increased the use of this technology recently. The Commonwealth’s vibrant solar industry has a variety of ownership and financing options for Massachusetts residents and businesses looking to install solar PV systems. Purchasing a solar PV system generally involves upfront installation and equipment costs, but there are significant upfront and production-‐based incentives1. As the Massachusetts clean energy sector grows, the Baker Administration is working to ensure that solar PV and other clean energy technologies are sited in a way that is most protective of human health and the environment, and minimizes impacts on scenic, natural, and historic resources. Purpose of Guide This guide is intended to help local decision-‐makers and community members answer common questions about ground-‐mounted solar PV development. Ground-‐mounted solar PV has many proven advantages and there has been a steady growth of well received projects in the Commonwealth. However, these systems are still relatively new and unfamiliar additions to our physical landscape. This guide focuses on questions that have been raised concerning the installation and operation of ground-‐mounted solar PV projects. It provides summaries and links to existing research and studies that can help understand solar PV technology in general and ground-‐mounted solar in particular. Solar PV panels can and are of course also installed on buildings2, car ports or light poles. This guide focuses on ground-‐mounted systems since most questions relate to this type of solar installation. Developed through the partnership of the Massachusetts Department of Energy Resources (DOER), the Massachusetts Department of Environmental Protection (MassDEP), and the Massachusetts Clean Energy Center (MassCEC), this guide draws from existing recent literature in the United States and abroad and is not the result of new original scientific studies. The text was reviewed by the National Renewable Energy Laboratory (NREL). As more or new information becomes available, the guide will be updated and expanded accordingly.
1
For a comprehensive overview, start at http://masscec.com/index.cfm/page/Solar-‐PV/pid/12584 For an overview of the multiple options for siting PV and buildings in the same footprint, see the Solar Ready Buildings Planning Guide, NREL, 2009. 2
3
Solar PV Projects Are Sited Locally The siting authority for solar PV projects resides at the local -‐ not the state -‐ level. One purpose of this guide is to inform and facilitate local efforts to expand clean energy generation in a sustainable way, and provide a consolidated source of existing research and information that addresses common questions faced by communities. As part of the Green Communities Act of 2008, DOER and the Massachusetts Executive Office of Energy and Environmental Affairs (EOEEA) developed a model zoning by-‐law/ordinance called “as-‐of-‐right siting” that does not require a special permit. It is designed to help communities considering adoption of zoning for siting of large-‐scale solar. This model zoning by-‐law/ordinance provides standards for the placement, design, construction, operation, monitoring, modification and removal of new large-‐scale ground-‐mounted solar PV installations. The latest version of the model by-‐law was published in December 20143. It provides useful information that will not be repeated extensively in this guide. Consider Impacts of Other Possible Developments at Site Use of land for the purpose of solar photovoltaic power generation should be compatible with most other types of land usage. However, DOER strongly discourages designating locations that require significant tree cutting because of the important water management, cooling and climate benefits trees provide. DOER encourages designating locations in industrial and commercial districts, or on vacant, disturbed land. When assessing the impact of new ground-‐mounted solar arrays, communities and other stakeholders should carefully consider other types of development that might take place in a particular location if there was no solar installation. Stakeholders should bear in mind the higher or lower impacts that those alternatives might have in terms of noise, air pollution or landscape. These alternative impacts fall outside the scope of this guide, but are relevant when looking at individual projects.
3
http://www.mass.gov/eea/docs/doer/green-‐communities/grant-‐program/model-‐solar-‐zoning.pdf
4
Hazardous Materials The Question: What, if any, health risks do chemicals used to manufacture solar panels and other devices used in solar PV arrays pose if they are released into the environment? Bottom Line: Because PV panel materials are enclosed, and don’t mix with water or vaporize into the air, there is little, if any, risk of chemical releases to the environment during normal use. The most common type of PV panel is made of tempered glass, which is quite strong. They pass hail tests, and are regularly installed in Arctic and Antarctic conditions. Only in the unlikely event of a sufficiently hot fire is there a slight chance that chemicals could be released. This is unlikely because most residential fires are not hot enough to melt PV components and PV systems must conform to state and federal fire safety, electrical and building codes. Transformers used at PV installations, that are similar to the ones used throughout the electricity distribution system in cities and towns, have the potential to release chemicals if they leak or catch fire. Transformer coolants containing halogens have some potential for toxic releases to the air if combusted. However, modern transformers typically use non-‐toxic coolants, such as mineral oils. Potential releases from transformers using these coolants at PV installations are not expected to present a risk to human health. More Information: Ground-‐mounted PV solar arrays are typically made up of panels of silicon solar cells covered by a thin layer of protective glass, which is attached to an inert solid underlying substance (or “substrate”). While the vast majority of PV panels currently in use are made of silicon, certain types of solar cells may contain cadmium telluride (CdTe), copper indium diselenide (CIS), and gallium arsenide (GaAs). All solar panel materials, including the chemicals noted above, are contained in a solid matrix, insoluble and non-‐volatile at ambient conditions, and enclosed. Therefore, releases to the ground from leaching, to the air from volatilization during use, or from panel breakage, are not a concern. Particulate emissions could only occur if the materials were ground to a fine dust, but there is no realistic scenario for this. Panels exposed to extremely high heat could emit vapors and particulates from PV panel components to the air. However, researchers have concluded that the potential for emissions derived from PV components during typical fires is limited given the relatively short-‐duration of most fires and the high melting point (>1000 degrees Celsius) of PV materials compared to the roof level temperatures typically observed during residential fires (800-‐900 degrees Celsius). In the rare instance where a solar panel might be subject to higher temperatures, the silicon and other chemicals that comprise the solar panel would likely bind to the glass that covers the PV cells and be retained there. Release of any toxic materials from solid state inverters is also unlikely provided appropriate electrical and installation requirements are followed. For more information on public safety and fire, see the Public Safety section of this document. We should also note that usually the rain is sufficient to keep the panels clean, so no extra cleaning in which cleaning products might be used, is necessary. 5
Resources: Fthenakis, V.M., Overview of Potential Hazards in Practical Handbook of Photovoltaics: Fundamentals and Applications, General editors T. Markvart and L. Castaner, to be published by Elsevier in 2003. Fthenakis, V.M. Life cycle impact analysis of cadmium in CdTe PV production. Renewable and Sustainable Energy Reviews 8, 303-‐334, 2004. Fthenakis V.M., Kim H.C., Colli A., and Kirchsteiger C., Evaluation of Risks in the Life Cycle of Photovoltaics in a Comparative Context, 21st European Photovoltaic Solar Energy Conference, Dresden, Germany, 4-‐8 September 2006. Moskowitz P. and Fthenakis V., Toxic materials released from photovoltaic modules during fires; health risks, Solar Cells, 29, 63-‐71, 1990. Sherwani, A.F., Usmani, J.A., & Varun. Life cycle assessment of solar PV based electricity generation systems: A review. Renewable and Sustainable Energy Reviews. 14, 540-‐544, 2010. Zayed, J; Philippe, S (2009-‐08). "Acute Oral and Inhalation Toxicities in Rats With Cadmium Telluride" (PDF). International journal of toxicology (International Journal of Toxicology) 28 (4): 259–65. doi:10.1177/1091581809337630. PMID 19636069. http://ijt.sagepub.com/cgi/content/short/28/4/259.
6
End-‐of-‐Life/Decommissioning Question: How do I manage solar panels after they are decommissioned and no longer in use? Can they be recycled and do hazardous waste disposal requirements apply? Bottom Line: As more solar panels are decommissioned interest in recycling the panels has increased in Europe and the U.S. Massachusetts regulations ensure proper disposal and recycling of panels if they have components that constitute solid or hazardous waste under state regulations. More information: The average life of solar PV panels can be 20-‐30 years (or longer) after initial installation. PV cells typically lose about 0.5% of their energy production capacity per year. At the time of decommissioning, panels may be reused, recycled or disposed. Since widespread use of solar PV is recent in Massachusetts, only a small percentage of solar panels in use in the state have had to be replaced due to damage or reached the end of their useful lifetime. A significant increase in the amount of end-‐of-‐life PV modules is expected over the next few decades. When solar panels are decommissioned and discarded, state rules require that panel disposal be “properly managed” pursuant to the Massachusetts hazardous waste regulations, 310 CMR 30.000. There are many different types of solar panels used in ground-‐mounted or roof mounted solar PV systems; some of these panels have components that may require special hazardous waste disposal or recycling. Solar module manufacturers typically provide a list of materials used in the manufacturing of their product, which may be used to determine the proper disposal requirements at the time of decommissioning. Under the hazardous waste regulations, the burden is on the generator of the panels to determine if the waste being generated (the solar panels) is hazardous or not. This determination can be made using “knowledge” (i.e. an MSDS sheet listing the materials used in manufacture of the panels) or testing (i.e. the Toxicity Characteristic Leaching Procedure – TCLP). If a panel is tested and passes TCLP then it is regulated as a solid waste; if it fails TCLP then it is regulated as a hazardous waste. However, if the solar panel is determined to be hazardous due solely to the presence of metal-‐bearing circuit boards, the panels may be conditionally exempt from the hazardous waste regulations if destined for recycling. See 310 CMR 30.202(5)(d)-‐(e) in the Mass. Hazardous Waste Regulations.4 People who lease land for solar projects are encouraged to include end-‐of-‐life panel management as part of the lease. In cases where panels are purchased, owners need to determine whether the end-‐of 4
(5) The following materials are not subject to 310 CMR 30.200, or any other provision of 310 CMR 30.000: (d) Whole used circuit boards being recycled provided they are free of mercury switches, mercury relays, nickel-‐cadmium batteries, or lithium batteries. (e) Shredded circuit boards being recycled provided that they are: 1. managed in containers sufficient to prevent a release to the environment prior to recovery; and, 2. free of mercury switches, mercury relays and nickel-‐cadmium batteries and lithium batteries.
7
life panels are a solid or hazardous waste and dispose or recycle the panels appropriately. Massachusetts regulations require testing of waste before disposal. Because of the various materials used to produce solar panels (such as metal and glass), interest in recycling of solar modules has grown. Throughout Europe, a not-‐for-‐profit association (PV Cycle) is managing a voluntary collection and recycling program for end-‐of-‐life PV modules. The American photovoltaic industry is not required by state or federal regulation to recycle its products, but several solar companies are starting to recycle on a voluntary basis. Some manufacturers are offering end-‐of-‐life recycling options and independent companies looking to recycle solar modules are growing. This allows for the recycling of the PV panels and prevents issues with the hazardous materials. Currently, the California Department of Toxic Substances Control is considering standards for the management of solar PV panels at the end of their use. DOER’s model zoning provides language on requirements for abandonment and decommissioning of solar panels for use by local officials considering local approvals for these projects. Resources End-‐of-‐life PV: then what? -‐ Recycling solar PV panels http://www.renewableenergyfocus.com/view/3005/end-‐of-‐life-‐pv-‐then-‐what-‐recycling-‐solar-‐pv-‐panels/ MassDEP Hazardous Waste Regulations 310 CMR 30.000 http://www.mass.gov/eea/agencies/massdep/recycle/regulations/310-‐cmr-‐30-‐000.html PV Cycle, Europe: http://www.pvcycle.org/ California Department of Toxic Substances Control, Proposed Standards for the Management of Hazardous Waste Solar Modules, http://www.dtsc.ca.gov/LawsRegsPolicies/Regs/Reg_Exempt_HW_Solar_Panels.cfm
8
Ambient Temperature (“Heat Island”) The Question: Does the presence of ground-‐mounted solar PV arrays cause higher ambient temperatures in the surrounding neighborhood (i.e., the “heat island” effect)? Bottom Line: All available evidence indicates that there is no solar “heat island” effect caused by the functioning of solar arrays. Cutting shade trees for solar PV might increase the need for cooling if those trees were shading buildings. This is primarily a concern in town centers and residential areas (locations where large ground-‐mounted PV is not encouraged) and is a potential impact of any development activity that requires tree-‐cutting. More Information: All available evidence indicates that there is no solar “heat island” effect caused by the functioning of solar arrays. Solar panels absorb photons from direct sunlight and convert it to electricity. This minimizes the likelihood of substantially changing temperatures at the site or the surrounding neighborhood. For an area with no PV system, solar energy impacting the ground is either reflected or absorbed. There is no research to support heat production from the solar panels themselves. Sunpower, a private solar manufacturer, conducted a study on the impact of solar PV on the local temperature, and concluded that a solar PV array can absorb a higher percentage of heat than a forested parcel of land without an array. The study points out that while solar PV modules can reach high operating temperatures up to 120 degrees Fahrenheit, they are thin and lightweight and therefore do not store a large amount of heat. Because of this, and the fact that panels are also shown to cool to ambient air temperature shortly after the sun sets, the Sunpower study concludes that the area surrounding a large-‐scale solar array is unlikely to experience a net heating change from the panels. If trees are removed that were previously shading a building, that building could get warmer in full sunshine than when the trees were shading it. The June 1, 2011 tornado that ripped through Western Massachusetts created an opportunity to empirically measure the effects of the loss of neighborhood trees on temperatures and air humidity in the streets. A report by the U.S. Department of Agriculture Forest Service concluded that daily mean morning and afternoon temperatures were typically greater in the tornado-‐impacted neighborhood in Springfield, Massachusetts than in the unaffected neighborhood and forest sites, but were similar at night. Residents noted increased use of air-‐conditioning units and an overall increase in energy costs in July and August of 2011. Resources: SUNPOWER, Impact of PV Systems on Local Temperature, July 2010 USDA Forest Services report: http://www.regreenspringfield.com/wp-‐ content/uploads/2011/11/tornado%20climate%20report%203.pdf
9
Electric and Magnetic Fields (EMF) The Question: What, if any, health risks do the electric and magnetic fields (EMF) from solar panels and other components of solar PV arrays pose? Bottom Line: Electric and magnetic fields are a normal part of life in the modern world. PV arrays generate EMF in the same extremely low frequency (ELF) range as electrical appliances and wiring found in most homes and buildings. The average daily background exposure to magnetic fields is estimated to be around one mG (milligauss – the unit used to measure magnetic field strength), but can vary considerably depending on a person’s exposure to EMF from household electrical devices and wiring. The lowest exposure level that has been potentially associated with a health effect is three mG. Measurements at three commercial PV arrays in Massachusetts demonstrated that their contributions to off-‐site EMF exposures were low (less than 0.5 mG at the site boundary), which is consistent with the drop off of EMF strength based on distance from the source. More Information: Solar PV panels, inverters and other components that make up solar PV arrays produce extremely low frequency EMF when generating and transmitting electricity. The extremely low frequency EMF from PV arrays is the same as the EMF people are exposed to from household electrical appliances, wiring in buildings, and power transmission lines (all at the power frequency of 60 hertz). EMF produced by cell phones, radios and microwaves is at much higher frequencies (30,000 hertz and above). Electric fields are present when a device is connected to a power source, but are shielded or blocked by common materials, resulting in low potential for exposures. On the other hand, magnetic fields, which are only generated when a device is turned on, are not easily shielded and pass through most objects, resulting in greater potential for exposure. Both types of fields are strongest at the source and their strength decreases rapidly as the distance from the source increases. For example, the magnetic field from a vacuum cleaner six inches away from the motor is 300 mG and decreases to two mG three feet away. People are exposed to EMF during normal use of electricity and exposure varies greatly over time, depending on the distance to various household appliances and the length of time they are on. The daily average background level of magnetic fields for US residents is one mG. EMF from PV Arrays: Solar PV panels produce low levels of extremely low frequency (ELF) EMF, with measured field strengths of less than one mG three inches from the panel. Solar PV power inverters, transformers and conduits generate higher levels of ELF-‐EMF. The amount of ELF-‐EMF is proportional to the electrical capacity of the inverter and is greater when more current (electricity) is flowing through a power line. In a study of two PV arrays (using 10-‐20 kW invertors) in Kerman and Davis, California, the magnetic field was highest at the inverters and transformers, but decreased rapidly to less than one mG within 50 feet of the units, well within the boundary of the PV array (Chang and Jennings 1994). This data indicates that extremely low frequency EMF field strengths at residences near systems of this size would be below the typical levels experienced by most people at home. The highest extremely low frequency EMF (up to 1,050 mG) was found next to an inverter unit at the point of entry of the electrical conduits. Even this 10
value is less than the extremely low frequency EMF reported for some common household devices such as an electric can opener with a maximum of 1500 mG at 6 inches. In a recent study of three ground mounted PV arrays in Massachusetts, the above results were confirmed. The PV arrays had a capacity range of 1 to 3.5 MW. Magnetic field levels along the PV array site boundary were in the very low range of 0.2 to 0.4 mG. Magnetic fields at 3 to 7 feet from the inverters ranged from 500 to 150 mG. At a distance of 150 feet from the inverters, these fields dropped back to very low levels of 0.5 mG or less, and in many cases to much less than background levels (0.2 mG). Potential Health Effects: Four research studies have reported an association between three to four mG EMF exposure and childhood leukemia, while 11 other studies have not. These studies are inconsistent and do not demonstrate a causal link that would trigger a World Health Organization (WHO) designation of EMF as a possible carcinogen5. Studies looking at other cancers in humans and animals have not found evidence of a link to residential ELF-‐EMF exposure. Reference Exposure Levels: To protect the general public from health effects from short-‐term high level magnetic fields, the International Commission on Non-‐Ionizing Radiation Protection (ICNIRP, 2010) advised an exposure limit for extremely low frequency magnetic fields at 2000 mG. ICNIRP determined that the evidence on the impact of long-‐term exposure to low level magnetic fields was too uncertain to use to set a guideline. Guidelines for the magnetic field allowed at the edge of transmission line right-‐of-‐ ways have been set at 200 mG by Florida and New York. Exposure to magnetic fields greater than 1000 mG is not recommended for people with pacemakers or defibrillators (ACGIH, 2001). Resources: American Conference of Government Industrial Hygienist (ACGIH). 2001. as cited in NIEHS 2002. Chang, GJ and Jennings, C. 1994. Magnetic field survey at PG&E photovoltaic sites. PG&E R&D Report 007.5-‐94-‐6. Electric Power Research Institute (EPRI). 2012. EMF and your health. http://my.epri.com/portal/server.pt?Abstract_id=000000000001023105. International Commission on Non-‐Ionizing Radiation Protection (ICNIRP). 2010. ICNIRP Guidelines for limiting exposure to time-‐varying electric and magnetic fields (1 Hz – 100kHz). Health Physics 99(6):818-‐ 836. National Cancer Institute (NCI). 2005. Magnetic Field Exposure and Cancer: Questions and Answers. U.S. Department of Health and Human Services, National Institutes of Health. Available http://www.cancer.gov/cancertopics/factsheet/Risk/magnetic-‐fields, accessed May 14, 2012. 5
WHO has designated ELF-‐EMF as a possible carcinogen. The use of the label “possible carcinogen” indicates that there is not enough evidence to designate ELF-‐EMF as a “probable carcinogen “or “human carcinogen,” the two indicators of higher potential for being carcinogenic in humans.
11
National Institute of Environmental Health Science (NIEHS) 2002. Electric and Magnetic Fields Associated with the Use of Electric Power: Questions and Answers. Available http://www.niehs.nih.gov/health/assets/docs_p_z/results_of_emf_research_emf_questions_answers_b ooklet.pdf, accessed May 11, 2012. National Institute of Environmental Health Science (NIEHS) web page on EMF. Available http://www.niehs.nih.gov/health/topics/agents/emf/, accessed May 11, 2012. Oregon Department of Transportation (Oregon DOT). Scaling public concerns of electromagnetic fields produced by solar photovoltaic arrays. Produced by Good Company for ODOT for the West Linn Solar Highway Project. Available www.oregon.gov/ODOT/HWY/OIPP/docs/emfconcerns.pdf. World Health Organization (WHO). 2007. Electromagnetic fields and public health: Exposure to extremely low frequency fields. Fact sheet N°322. June 2007. Available http://www.who.int/mediacentre/factsheets/fs322/en/index.html, accessed May 16, 2012. This fact sheet provides a short summary of the in-‐depth review documented in the WHO 2007, Environmental Health Criteria 238. Available http://www.who.int/peh-‐emf/publications/elf_ehc/en/index.html.
12
Property Values Question: How do ground-‐mounted solar PV arrays adjacent to residential neighborhoods influence the property values in those neighborhoods? Bottom Line: No research was found specific to ground-‐mounted solar PV and property values. Residential property value research on roof-‐mounted solar PV and wind turbines illustrates no evidence of devaluation of homes in the area. Municipalities that adopt zoning for solar facilities may want to consider encouraging project developers to include screening vegetation along site borders to minimize visual impacts on surrounding neighborhoods. More Information: A review of literature nationwide shows little evidence that solar arrays influence nearby property values. An analysis focused on roof-‐mounted solar PV done by the U.S. Department of Energy Lawrence Berkeley National Laboratory concludes that household solar installation actually increases home property values. This research analyzes a large dataset of California homes that sold from 2000 through mid-‐2009 with PV installed. Across a large number of repeat sales model specifications and robustness tests, the analysis finds strong evidence that California homes with PV systems have sold for a premium over comparable homes without PV systems. Resources: An Analysis of the Effects of Residential Photovoltaic Energy Systems on Home Sales Prices in California http://emp.lbl.gov/sites/all/files/lbnl-‐4476e.pdf
13
Public Safety (including fires) Question: What public safety issues arise from people’s (including children) access to areas where solar arrays are installed? Can electrical and other equipment associated with solar projects cause electrical fires? Bottom Line: Large-‐scale ground-‐mounted arrays are typically enclosed by fencing. This prevents children and the general public from coming into contact with the installations, thus preventing unsafe situations. The National Electric Code has mandatory requirements to promote the electrical safety of solar PV arrays. Emergency personnel responding to potential emergencies at a solar PV site face the most risk, but the solar industry and firefighters provide training and education for emergency personnel to ensure that the proper safety precautions are taken. More Information: The National Electric Code has mandatory requirements for the electrical safety of solar PV arrays. To protect against intruders, Article 690 of the National Electric Code covers the safety standards for solar PV installation and requires that conductors installed as part of solar PV be “not readily accessible”. With a large-‐scale ground-‐mounted array, a fence is typically installed around the system to prevent intruders. Some communities have solar PV or signage by-‐laws that require identification of the system owner and 24-‐hour emergency contact information. DOER’s Model by-‐Law/ordinance requires owners of solar PV facilities to provide a copy of the project summary, electrical schematic, and site plan to the local fire chief, who can then work with the owner and local emergency services to develop an emergency response plan. These measures can be combined with products to prevent theft of the panels. Some are very low cost options (fastener type) while there are other options that are more expensive (alarm system type) but also more effective. The biggest potential risk associated with solar PV systems is the risk of shock or electrocution for firefighters and other emergency responders who could come in contact with high voltage conductors. A 2010 study on firefighter safety and emergency response for solar PV systems by the Fire Protection Research Foundation, based in Quincy, Massachusetts, recommended steps firefighters can take when dealing with wiring and other components that may be energized. The Solar Energy Business Association of New England (SEBANE) has been working to provide training and education to first-‐responders to identify and avoid potential hazards when responding to a solar PV fire. For more information about toxics/fires, see the Hazardous Materials Section. Resources: Moskowitz, P.D. and Fthenakis, V.M., Toxic Materials Released from Photovoltaic Modules During Fires: Health Risks, Solar Cells, 29, 63-‐71, 1990. 21. Solar America Board for Codes and Standards http://www.solarabcs.org/about/publications/reports/blindspot/pdfs/BlindSpot.pdf Fire Fighter Safety and Emergency Response for Solar Power Systems: Final Report, May 2010. Prepared by The Fire Protection Research Foundation 14
National Electric Code Article 250: Grounding and Bonding, Article 300: Wiring Methods, Article 690 Solar PV Systems, Article 705 Interconnected Electric Power Production Sources
15
Historic Preservation The Question: What are the appropriate standards when land with historical or archaeological significance is developed for large-‐scale solar PV arrays? Bottom Line: Parties undertaking solar PV projects with state or federal agency involvement must provide the Massachusetts Historical Commission (MHC) with complete project information as early as possible in the planning stage, by mail to the MHC’s office (see Resources). Parties should also contact local planning, historical or historic district commissions to learn about any required local approvals. Municipalities should also take the presence of historic resources into account when establishing zoning regulations for solar energy facilities in order to avoid or minimize impacts. More Information: Land being evaluated for the siting of large-‐scale solar PV has historical or archaeological significance including properties listed in the National or State Registers of Historic Places and/or the Inventory of Historic and Archaeological Assets of the Commonwealth. Federal and state laws require that any new construction, demolition or rehabilitation projects (including new construction of solar PV) that propose to use funding, licenses or permits from federal or state government agencies must be reviewed by the MHC so that feasible alternatives are developed and implemented to avoid or mitigate any adverse effects to historic and archaeological properties. Projects receiving federal funding, licenses or permits are reviewed by the involved federal agency in consultation with the MHC and other parties in compliance with Section 106 of the National Historic Preservation Act of 1966 (16 U.S.C. 470f) and the implementing regulations (36 CFR 800) in order to reach agreement to resolve any adverse effects. Projects receiving state funding, licenses or permits must notify the MHC in compliance with M.G.L. c. 9, ss. 26-‐27C and the implementing regulations 950 CMR 71. If the MHC determines that the project will have an adverse effect, the involved state agency, the project proponent, the local historical preservation agencies, and other interested parties consult to reach an agreement that outlines measures to be implemented to avoid, minimize, or mitigate adverse effects. For projects with both federal and state agency involvement, the Section 106 process is used. Some communities have local preservation ordinances or established local historic districts that require local approval for new construction visible from a public way. Local historic district commissions have adopted design guidelines for new construction within their historic districts and historic neighborhoods. However, these guidelines must account for Chapter 40C Section 7 of the General Laws, which requires a historic district commission to consider the policy of the Commonwealth to encourage the use of solar energy systems and to protect solar access. Resources: Federal Agency Assisted Projects: Section 106 review information and the federal regulations 36 CFR 800 are available at the Advisory Council on Historic Preservation (ACHP) web site: www.achp.gov. Check with the involved federal agency for how they propose to initiate the MHC notification required by 36 CFR 800.3. State Agency Assisted Projects: 16
Massachusetts General Laws Chapter 9, sections 26-‐27C MHC Regulations 950 CMR 71 (available from the State House Bookstore) MHC Review & Compliance FAQs http://www.sec.state.ma.us/mhc/mhcrevcom/revcomidx.htm MHC Project Notification Form (PNF) & Guidance for Completing the PNF and required attachments (USGS locus map, project plans, current photographs keyed to the plan). Mail or deliver the complete project information to the MHC’s office: http://www.sec.state.ma.us/mhc/mhcform/formidx.htm General Guidance about Designing Solar PV Projects on Historic Buildings and in Historic Areas: http://www.nrel.gov/docs/fy11osti/51297.pdf
17
Noise Question: Do the inverters, transformers or other equipment used as part of ground-‐mounted solar PV create noise that will impact the surrounding neighborhood? Bottom Line: Ground-‐mounted solar PV array inverters and transformers make a humming noise during daytime, when the array generates electricity. At 50 to 150 feet from the boundary of the arrays, any sound from the inverters is inaudible. Parties that are planning and designing ground-‐mounted solar PV should explore options to minimize noise impacts to surrounding areas. This could include conducting pre-‐construction sound studies, evaluating where to place transformers, and undertaking appropriate noise mitigation measures. More Information: Most typically, the source of noise associated with ground-‐mounted solar PV comes from inverters and transformers. There also may be some minimal noise from switching gear associated with power substations. The crackling or hissing sound caused by high-‐voltage transmission lines (the “Corona Effect”) is not a concern in the case of solar PV, which uses lower voltage lines. Parties siting ground-‐mounted solar PV projects should consult equipment manufacturers to obtain information about sound that can be expected from electrical equipment, since this can vary. For example, according to manufacturer’s information, a SatCon Powergate Plus 1 MW Commercial Solar PV Inverter has an unshielded noise rating of 65 decibels (dBA) at five feet. This is approximately the sound equivalent of having a normal conversation with someone three feet away. Another source of information is the National Electrical Manufacturers Association (NEMA) standards, which will provide maximum sound levels from various equipment arrays. From NEMA, a large dry-‐type transformer (2001-‐3333 kVA) that is forced air cooled and ventilated has an average sound level of 71 dBA, which is approximately the sound level one would expect from a vacuum cleaner at ten feet. There may be several such units on a substantially sized PV site, which would increase the sound level to some degree. Sound impacts from electrical equipment can be modeled to the property line or nearest sensitive receptor (residence). Sound impacts can be mitigated with the use of enclosures, shielding and careful placement of the sound-‐generating equipment on-‐site. The rule of thumb for siting noise-‐generating equipment is that the sound impact can be reduced by half by doubling the distance to the receptor. In some areas both in the US and Canada, sound impact analysis is required as part of the permitting process for large PV systems. For example, in the Province of Ontario, Canada, any project greater than 12 MW is required to perform a sound impact analysis (Ontario 359/09). California also requires a sound impact analysis for large PV projects. Massachusetts currently has no such requirement, but the reader should note that ground-‐mounted systems in Massachusetts very rarely go over 6 MW, which is half the size of the 12 MW that triggers a sound analysis in Ontario. A recent study measured noise levels at set distances from the inverters and from the outer boundary of three ground-‐mounted PV arrays in Massachusetts with a capacity range of 1 to 3.5 MW. Close to the inverters (10 feet), sound levels varied from an average of 55 dBA to 65 dBA. Sound levels along the fenced boundary of the PV arrays were generally at background levels, though a faint inverter hum could be heard at some locations. Any sound from the PV array and equipment was inaudible and 18
sound levels were at background levels at setback distances of 50 to 150 feet from the boundary. Project developers should consult with local planning and zoning officials to determine if local noise ordinances may be applicable. Many local noise ordinances establish absolute limits on project impact noise (such as a 40 dBA nighttime limit). In these communities, a noise impact assessment may be required. Resources: NEMA Standards Publication No. TR=1-‐1993(R2000), Transformers, Regulators and Reactors Noise Assessment: Borrego 1 Solar Project, MUP 3300-‐10-‐26 Prepared by Ldn Consulting, Inc, Fallbrook, CA. January 14, 2011 Ontario Regulation 359/09 Renewable Energy Approval (REA) Regulation, Ontario Ministry of the Environment, Canada http://www.ontario.ca/environment-‐and-‐energy/renewable-‐energy-‐approvals Tech Environmental, Study of Acoustic and EMF levels from Solar Photovoltaic Projects, Prepared for the Massachusetts Clean Energy Center, December 2012, http://images.masscec.com/uploads/attachments/Create%20Basic%20page/Study_of_Acoustic_and_E MF_Levels_from_Solar_Photovoltaic_Projects.pdf
19
Water-‐Related Impacts Question: Can chemicals that might be contained in solar PV threaten public drinking water systems? Will flooding occur in cases where trees must be removed in order to install the solar arrays? How do we ensure that wetland resources are protected? Bottom Line: Rules are in place to ensure that ground-‐mounted solar arrays are installed in a ways that protect public water supplies, wetlands, and other water resource areas. All solar panels are contained in a solid matrix, are insoluble and are enclosed. Therefore, releases are not a concern. More Information: Because trees offer multiple water management, cooling and climate benefits, clear-‐cutting of trees for the installation of ground-‐mounted solar PV is discouraged. For projects that do propose to alter trees, the Massachusetts Environmental Policy Act (MEPA) has thresholds for the proposed alteration of a certain number of acres of land, the size of electrical facilities, and other criteria that trigger state review of proposed projects. Clear cutting of trees and other aspects of proposed projects would be reviewed through an Environmental Notification Form/Environmental Impact Statement if thresholds are triggered. More information is available at: MassDEP has determined that the installation of solar arrays can be compatible with the operation and protection of public drinking water systems. This includes the installation of solar arrays within the Zone I, which is a 400-‐foot protective radius around a public ground water well. Solar projects proposed on lands owned by public water systems outside the Zone I may be approved subject to standard best management practices, such as the proper labeling, storage, use, and disposal of products. MassDEP has a guidance/review process in place to ensure that the installation of ground-‐mounted solar PV in these areas protects public water supplies. Installing solar arrays on undeveloped land can preserve the permeable nature of the land surface provided the project design minimizes disturbance to natural vegetative cover, avoids concentrated runoff, and precipitation is otherwise recharged into the ground to the greatest extent practicable. Storm water flow, as well as information about site-‐specific soils and slope, is taken into account during the design and installation of solar arrays. MassDEP discourages installation of ground-‐mounted solar PV systems in wetland areas, including riverfront locations. Solar projects within wetland areas are unlikely to comply with the performance standards in the Wetlands Protection Act regulations. If a solar installation is proposed in a wetland, a riverfront area, a floodplain, or within 100 feet of certain wetlands, the project proponent must file a notice of intent (or application to work in wetland areas) with the local Conservation Commission, which administers the Wetlands Protection Act at the municipal level. Copies should also go to MassDEP. Solar installations may be sited near, but outside of wetlands, in a manner that protects the functions of wetlands and that minimizes impacts from associated activities such as access and maintenance. Ancillary structures related to construction of a solar installation or transmission of power may be permitted to cross rivers and streams using best design and management practices.
20
Resources: More information about the Wetlands Protection Act requirements may be found in the implementing regulations at 310 CMR 10.00: http://www.mass.gov/eea/agencies/massdep/water/regulations/310-‐ cmr-‐10-‐00-‐wetlands-‐protection-‐act-‐regulations.html MassDEP Guidance for Siting Wind and Solar in Public Water Supply Land: http://www.mass.gov/eea/agencies/massdep/water/regulations/wind-‐and-‐solar-‐energy-‐project-‐on-‐ public-‐water-‐supply-‐land.html MassDEP Chapter 91 Guidance for Renewable Energy Projects: http://www.mass.gov/eea/agencies/massdep/water/reports/chapter-‐91-‐licensing-‐and-‐renewable-‐ energy.html
21
Glare Question: How important is reflectivity and potential visual impacts from solar projects, especially near airports? Bottom Line: Solar panels are designed to reflect only about 2 percent of incoming light, so issues with glare from PV panels are rare. Pre-‐construction modeling can ensure that the placement of solar panels prevents glare. More Information: Solar panels are designed to absorb solar energy and convert it into electricity. Most are designed with anti-‐reflective glass front surfaces to capture and retain as much of the solar spectrum as possible. Solar module glass has less reflectivity than water or window glass. Typical panels are designed to reflect only about 2 percent of incoming sunlight. Reflected light from solar panels will have a significantly lower intensity than glare from direct sunlight. An analysis of a proposed 25-‐degree fixed-‐tilt flat-‐plate polycrystalline PV system located outside of Las Vegas, Nevada showed that the potential for hazardous glare from flat-‐plate PV systems is similar to that of smooth water and not expected to be a hazard to air navigation. Many projects throughout the US and the world have been installed near airports with no impact on flight operations. United Kingdom and U.S. aircraft accident databases contain no cases of accidents in which glare caused by a solar energy facility was cited as a factor. When siting solar PV arrays pre-‐construction modeling can ensure the panels are placed in a way that minimizes any potential glare to surrounding areas. Resources: Technical Guidance for Evaluating Selected Solar Technologies on Airports, Federal Aviation Administration, November 2010 (currently under review), http://www.faa.gov/airports/environmental/policy_guidance/media/airport_solar_guide.pdf A Study of the Hazardous Glare Potential to Aviators from Utility-‐Scale Flat-‐Plate Photovoltaic Systems, Black & Veatch Corporation, August 2011, http://www.isrn.com/journals/re/2011/651857/ Solar Photovoltaic Energy Facilities, Assessment of Potential Impact on Aviation, Spaven Consulting, January 2011: http://www.solarchoice.net.au/blog/solar-‐panels-‐near-‐airports-‐glare-‐issue/ 22
Endangered Species and Natural Heritage Question: Who ensures that rare animal and plant species and their habitats are not displaced or destroyed during the construction of ground-‐mounted solar PV? Bottom Line: Rules are in place to ensure that the installation of ground-‐mounted solar arrays protects state-‐listed rare species and animals and plants. Project proponents can check with the local Conservation Commission to determine if the footprint of the solar PV project lies within a rare species habtat. More Information: The Massachusetts Natural Heritage and Endangered Species Program (NEHSP) was created under the Massachusetts Endangered Species Act (MESA) and is responsible for protecting rare animal and plant species and their habitats from being displaced or destroyed. Specifically, NEHSP reviews projects proposed for: •
•
Priority Habitats: These are areas known to be populated by state-‐listed rare species of animals or plants. Any project that could result in the alteration of more than two acres of Priority Habitat is subject to NHESP regulatory review. Projects will need to file a MESA Information Request Form, along with a project plan, a U.S. Geological Survey (USGS) topographical map of the site, and a $50 processing fee. NHESP will let project administrators know within 30 days if the filing is complete, then will determine within the next 60 days whether the project, as proposed, would result in a “take” of state-‐listed rare species that might require the project to redesign, scale down, or abandon its plan. Estimated Habitats: These are a sub-‐set of Priority Habitats that are based on the geographical range of state-‐listed rare wildlife – particularly animals that live in and around wetlands. If the project is proposed for one of these areas and the local Conservation Commission requires filing a Notice of Intent (NOI) under the Wetlands Protection Act, the project will need to submit copies of the NOI, project plans and a U.S. Geological Survey (USGS) topographical map to NHESP. Within 30 days of receiving this information, NHESP will send its comments to the Conservation Commission, with copies to the project administrator, project consultants, and the Department of Environmental Protection (MassDEP).
Resources: To learn more about the NHESP review process and download a MESA Information Request Form, visit: http://www.mass.gov/eea/agencies/dfg/dfw/natural-‐heritage/regulatory-‐review/mass-‐endangered-‐ species-‐act-‐mesa/ For list of rare animal and plant species in Massachusetts, visit: http://www.mass.gov/eea/agencies/dfg/dfw/natural-‐heritage/species-‐information-‐and-‐ conservation/mesa-‐list/list-‐of-‐rare-‐species-‐in-‐massachusetts.html
23
24
Special Permit CEC Solar #1206, LLC Hopkinton, Massachusetts
TABLE OF CONTENTS 1.0
SPECIAL PERMIT FORM .......................................................................................................................... 1-1
2.0
PROJECT NARRATIVE .............................................................................................................................. 2-1
2.1 INTRODUCTION ............................................................................................................................................ 2-1 2.2 EXISTING CONDITIONS ................................................................................................................................. 2-1 2.3 PROPOSED CONDITIONS ............................................................................................................................... 2-2 2.4 COMPLIANCE WITH ZONING BYLAW ............................................................................................................ 2-4 2.4.1 Article XXXI, Commercial Solar Photovoltaic Installation ............................................................... 2-4 2.4.2 Article XXXI, Section 210-203 Administration .................................................................................. 2-7 2.4.2.1 2.4.2.2
2.4.3
Section 210-203.D. Approval Criteria ............................................................................................................ 2-7 Section 210-203.F. ......................................................................................................................................... 2-8
Performance Bond ............................................................................................................................. 2-9
3.0
ABUTTER INFORMATION ............................................................................................................................ 1
4.0
STORMWATER MANAGEMENT INFORMATION .............................................................................. 4-1
5.0
PLANS ............................................................................................................................................................ 5-1
Section 1.0 Special Permit Form Special Permit Application Form
Indicate below the Special Permit(s) requested by this application: Off-Street Parking Facility in a Business (B) District (§ 210-19G) Off-Street Parking Facility in a Downtown Business (BD) District (§ 210-20.3G) Shared and Off-Site Parking (§ 210-124) Parking Space Reduction (§ 210-124.D) Common Driveway (§ 210-120) Hotel Overlay District Use (§ 210-20.3G) Office Park District Use (§ 210-185) Open Space and Landscape Preservation Development Concept Plan (Article XVII) Campus Style Development (Article XIV) Village Housing in Residential Districts (Article XIIIA) Garden Apartments in Residential Districts (Article XIII) Flexible Community Development (Article XI) Commercial Solar Photovoltaic Installations (Article XXXI) Drive-in, Drive-through or Drive-up Uses (§ 210-19.D, § 210-20.3.D, § 210-24.F) Registered Marijuana Dispensary (Article XXXIII) Other ________________________________________________ Supplemental Information Common Driveway Applications Only: N/A
N/A
Will an Approval-Not-Required (ANR) plan be submitted to the Planning Board to create or modify the lots which will share the common driveway? Yes No Will a definitive subdivision plan be submitted to the Planning Board to create or modify the lots which will share the common driveway? Yes No
Hotel Overlay District and Office Park District Applications Only: Not applicable. List specific uses requested: _________________________________________________
________________________________________________________________________ ________________________________________________________________________ Procedure 1. Special Permit applications must be filed by the applicant with the Town Clerk.
11/16/2015
2
2. A public hearing will be scheduled by the Department of Land Use, Planning & Permitting (the “Department”) and the hearing held within 65 days of receipt of a complete application. 3. The Department will publish a legal notice in the MetroWest Daily News, for which the applicant will receive the bill directly from and payable to the newspaper. The Department will notify abutters by first class mail of the public hearing. 4. Either the applicant or a representative is expected to appear at the public hearing to explain the request. 5. The Planning Board must file a decision with the Town Clerk within 90 days of the close of the public hearing. Submission Requirements Applicants must attach and/or submit the following information with the application form. Please note that all materials, including this application, must be submitted on paper and electronically. For guidance as to the format of electronic submissions, see the Planning Board’s adopted Administrative Rules. Fees, in accordance with the Fee Schedule All required copies of plans, materials and documentation, in accordance with the Submission Requirements specific to each Special Permit request. Applications will not be considered complete until all the required materials are submitted. A description of how the special permit, if issued, will be in harmony with the general purpose and intent of the Zoning Bylaw, and how it will conform to any specific decision criteria contained in the Zoning Bylaw applicable to the request. Certified list of abutters within 300 feet of the property, from the Board of Assessors office. The list shall include abutters across any street and in adjacent communities, where applicable. The list of abutters shall have been certified within 90 days of the date of submission. Two envelopes for each abutter on the certified list of abutters, stamped with postage sufficient to send first class mail to each, and 12 envelopes stamped with first class postage for the required notification to abutting communities. An applicant may request, in writing, that the Planning Board waive specific submission requirements. The Board may waive the submission of specific items if it determines that the item is not necessary or not applicable to a specific project or application. If a Special Permit application is submitted concurrently with a Site Plan Review application, then the materials required shall be cumulative, with the exception of the number of envelopes and postage for each abutter and the abutters list. All information may be shown on one set of plans. Fee Schedule If more than one Special Permit is requested by an application, the administrative fee shall be the highest individual fee required regardless of the number of Special Permits requested. The consultant review fee shall be the sum of the two highest required. If this application is submitted concurrently with an application for Site Plan Review, the administrative fee shall be the highest
11/16/2015
3
of the individual fees, and shall not be cumulative1. The consultant review fee shall be the sum of the two highest required.
Special Permit Off Street Parking Facility Shared and Off Site Parking Parking Space Reduction Common Driveways Hotel and/or accessory uses in the Hotel Overlay District Office Park District uses: Residential dormitory component of a conference center; Public transportation facilities Office Park District use: Continuing care retirement community, assisted living facility or similar institution Campus Style Development OSLPD Concept Plan
Garden Apartments in Residential Districts Village Housing
Flexible Community Development
Flexible Community Development – Request for Extension Commercial Solar Photovoltaic Installation Drive-in, Drive-through or Drive-up Uses Registered Marijuana
11/16/2015
Special Permit Application Administrative Consultant Review Fee Fee $1,200.00 $2,000.00
Amendment Administrative Consultant Fee Review Fee $500.00 $1,000.00
$1,200.00
$2,000.00
$500.00
$1,000.00
$300.00 $500.00 $1,800.00
None $1,500.00 $2,000.00
$300.00 $200.00 $500.00
None $500.00 $1,000.00
$600.00
$2,000.00
$500.00
$1,000.00
$1,800.00
$2,000.00
$500.00
$1,000.00
$600.00
$1,000.00
None
None
$600.00 plus $50.00 for every lot above 5 $500.00 plus $10.00 per dwelling unit $150.00 plus $3.00 per dwelling unit $1,000.00
1 to 5 lots: $1,000.00 6 or more lots: $500.00 per lot $2,000.00 plus $500.00 for every 5 acres over 30 acres $2,000.00 plus $500 for every 5 acres over 20 acres $1,000.00 plus $10.00 per dwelling unit
None
None
$400.00
Actual cost
$400.00
Actual cost
$500.00
$50.00
None
$50.00 if no public hearing required; $100.00 if public hearing required NA
$500.00
$1,500.00
$100.00
Actual cost
$250.001
None
$50.00
None
$600.00
$1,500.00
$100.00
Actual cost
4
NA
Dispensary All Other Special Permits
$300.00
$1,000.00
1
$300.00
Actual cost
The administrative fee required with the Special Permit Application for drive-in, drive-through or drive-up uses is $0 if submitted concurrently with an application for Site Plan Review.
11/16/2015
5
Commercial Solar Photovoltaic Installations – Submission Requirements 1. Nine (9) paper copies of the following documents and information in narrative form. Include proposed mitigation where applicable. (a) A statement describing why an application for a Special Permit has been submitted, including the applicant’s objectives and why the Planning Board should grant the request. (b) A statement describing how the proposal complies with the Approval Criteria contained in the Zoning Bylaw. (§ 210-203.D) (c) A list of all other required permits and approvals and the status of each. (d) A description of the current use of the property. (e) Identification of the entities intended to own, operate and maintain the property and the facilities thereon. (f) Proposed forms of deed restrictions and any other existing or proposed agreements between property owners within and outside of the property, if any. (g) An environmental analysis of the impact of the project/facility, including an evaluation of pre-development conditions and post-development conditions on surface and groundwater quality, groundwater recharge, wildlife habitat and corridors, wetlands and bodies of water, including streams and rivers, and all documentation and calculations related thereto. (h) A recommended performance bond amount which may be posted with the Town to guarantee proper maintenance and/or removal of the installation, which shall not exceed the estimated cost of the installation’s removal. Provide information adequate to support the proposed amount. 2. Nine (9) copies of a plan set at a scale of 1” = 40’, on sheet sizes 24” x 36” and one reduced plan set on 11” x 17” paper, prepared by a registered professional engineer unless indicated otherwise by the Board, which shows the information below, at a minimum. (a) Locus plan at a scale of 1” = 800’. (b) The plan set shall include a Zoning Table which lists all applicable area, setback, yard and buffer requirements and the proposed compliance with each. For example, the table shall indicate “Minimum Lot Area” and list “3 acres” in a “Required” column, and in a “Proposed” column it shall indicate the size of the lot containing the installation. (c) Existing Conditions Plan which shows the property, zoning district boundaries, property boundaries and easements, structures on adjacent properties within 50 ft. of the property line, topography at 5 ft. contour intervals, vegetative cover, wetlands, water bodies, historic structures, roads and ways, significant environmental features such as ledge outcrops, scenic views and large trees, and the location, size and shape of existing structures and a notation as to whether they will be removed or retained. 11/16/2015
25
(d) The proposed layout of the property, including the proposed commercial solar photovoltaic installation and other structures with the setbacks and exterior dimensions noted, the limit of site clearing, the location of existing and proposed roads, driveways and utilities, stormwater management system and the layout of proposed parking areas. (e) A detail which depicts the typical solar PV collection structure and their dimensions. (f) The location and dimensions of existing and proposed electrical transformers, inverters and the like, both above and below ground. (g) Proposed methods of screening the premises from abutting property and the street. (h) Proposed security fences. (i) Proposed site lighting including intensity, mounting height, design and direction. (j) Proposed signage.
11/16/2015
26
Section 2.0 Project Narrative
Special Permit Application CEC Solar #1206, LLC Hopkinton, Massachusetts
2.0
PROJECT NARRATIVE
2.1
Introduction The Subject Property (the Property) is located at 147 Lumber Street in Hopkinton, Massachusetts, and is currently a single-family dwelling. An adjacent parcel, off Alexander Street, is also included as part of this proposed development. The 2.9 MW (DC) solar array installation is proposed on a ±11.4-acre portion (the Site) of the larger property (±41.5 acres) located at 147 Lumber Street (the Property) according to Assessor’s information. Refer to Figure 1, Locus Map and Figure 2, Aerial Map.
2.2
Existing Conditions The Property is bounded to the south by single-family residences, to the north by undeveloped and forested land, and to the east and west by single-family residences and undeveloped forested land. The Site lies east of Lumber Street and west of Alexander Road and Daniel Road. The larger Property within which the Site lies is identified as Hopkinton Assessor’s Map R29-15-0 and R30-1-A, two parcels totaling ±41.5 acres owned by Benedict J. and Amy Chirco. The Site currently contains undeveloped forested land which will be cleared of vegetation prior to installation. The land immediately surrounding the Site is predominantly forested and residential. North of the Site, land appears to have been cleared but has not been developed. The proposed location of the Project is approximately 240 feet from the nearest residence on the western side of the Site and ±235 feet from the nearest residence on the eastern side of the Site. The remaining residences in the area are well-removed from the Array. Refer to Section 2.0 Pre-Development Conditions of the Stormwater Management Report included in Section 4.0 of this Application for detailed topographic and soils information. There are two areas of Bordering Vegetated Wetlands (BVW) located on-site. The first area is located north of the existing access driveway, along Lumber Street, on the western side of the Property. This BVW consists of forested red maple swamp associated with a stream located on the Site, of which the access driveway crosses. The second BVW is located on the eastern portion of the Property and consists of a red maple swamp. A Notice of Intent will be filed for the portions of work subject to the Conservation Commission’s jurisdiction subsequent to the filing of this application. According to the Massachusetts Cultural Resource Information System (MACRIS), there are no historical resources located on the Site. Additionally, the proposed work does not involve activities that would adversely impact potential surrounding historic resources, such as the residences on either side of the driveway connection at Lumber Street.
Project Narrative
2-1
Special Permit Application CEC Solar #1206, LLC Hopkinton, Massachusetts
According to the Massachusetts Natural Heritage Atlas 13th Edition, dated October 1, 2008, and confirmed current with MassGIS information on May 31, 2017, the Site is not located within Natural Heritage and Endangered Species Program (NHESP) designated Priority Habitat of Rare Species or Estimated Habitat of Rare Wildlife. There are no potential or certified vernal pools identified by NHESP within the Site. 2.3
Proposed Conditions The proposed system size will be a 2.9 MW (DC) facility proposed on a ±11.4-acre portion (the Site) of the larger Property (±41.5 acres) located at 147 Lumber Street. Relevant details relating to the solar system components are included on the enclosed plans. The Property is located in two residential zoning districts, the Agriculture (A) district and the Residential B (RB) district. However, the Site is located solely within the A district. In terms of zoning requirements, the A District is more restrictive than the RB district; therefore, the Project will conform to the requirements of the A district, per the Hopkinton Zoning Bylaw. As required and detailed herein, the proposed location of the solar array area provides a minimum 60-foot setback from Lumber Street (front yard), and minimum 30-foot setbacks from the side and rear yards. These setbacks are measured from the security fence surrounding the solar panels, as required in the Zoning Bylaw. The Array will encompass approximately ±9.5 acres (fenced area) and will connect to the electrical grid at Lumber Street. The Array has been designed so that the clearing for the Array and security fence will be located outside of jurisdictional wetland areas as established by the Hopkinton Wetlands Protection Bylaw. A vegetated buffer along the access drive, south of the western Array, will be maintained with a combination of Green Giant Arborvitae (Thuja ‘Green Giant’) and Woodwardii American Arborvitae (Thuja occidentalis ‘Woodwardii’). The Woodwardii American Arborvitae will be planted five (5)-feet on-center and the Green Giant Arbovitae will be planted eight (8)-feet on-center. A total of 12 Woodwardii Arborvitae are proposed to be planted and a total of 134 Green Giant Arborvitae are proposed to be planted. Refer to Plans in Section 5.0. A seven-foot high, galvanized chain link fence, with no top horizontal rail (to mitigate potential visual impact), will be installed around the perimeter of the array, outside of the required zoning setbacks from adjacent property lines. The fence will be a wooden stockade-style along the western boundary of the southern portion of the array. The driveway accessing the Array is an existing paved driveway and will be extended and/or improved to adequately provide access for emergency and maintenance vehicles.
Project Narrative
2-2
Special Permit Application CEC Solar #1206, LLC Hopkinton, Massachusetts
Construction access to the Site will be gained via the existing driveway on Lumber Street. The proposed construction sequence is provided below:
Contractor shall have the limit of all erosion control barriers staked prior to any construction activities.
Erosion control and stone construction entrance shall be installed and inspected prior to initiating earthwork.
All greater than 3:1 slopes, shall be stabilized with an erosion control blanket.
Install the solar panel support posts and racks.
Install the solar panels and electrical conduits.
Loam and seed all disturbed areas as construction progresses.
Provide ongoing maintenance of disturbed areas until disturbed areas are 100% stabilized.
Construction sequence may vary to minimize disturbance on-site and all erosion controls will be maintained until full stabilization.
All material modifications as determined by the Building Inspector to be a major modification for the Array made after the issuance of the required building permit shall require approval by the Planning Board.
All construction activity shall occur between the hours of 7:00 AM and 5:00 PM on Monday through Saturday, only. Construction activity includes staging, deliveries, equipment warm up, or other supporting construction activities.
Once the Project is complete, there will be no outside storage of equipment or solar panels on the Site.
An as-built plan shall be submitted and approved by the Hopkinton Building Inspector and Hopkinton Planning Board prior to the issuance of an occupancy permit.
Vegetation control on the Site shall be mechanical only and no pesticides or other chemical products shall be used.
Project Narrative
2-3
Special Permit Application CEC Solar #1206, LLC Hopkinton, Massachusetts
Refer to Section 3.0 Post-Development Conditions of the Stormwater Management Report included in Section 4.0 of this application regarding information on existing and proposed hydrology and compliance with the DEP Stormwater Management Policy. Potential soil erosion will be mitigated by the use of straw bales with silt fencing as erosion control barriers, with straw wattles or some other intermediate erosion control measure inside of the perimeter of ECBs, given the long uninterrupted slopes down to the resource areas. Additionally, the construction entrance will be stabilized crushed stone, temporary sedimentation basins and potentially catch basin sediment bags will also be utilized where appropriate. Refer to the attached plan set as well as the Site Owner’s Manual in Section 4.0 for detailed information regarding the best management practices to be used to control soil erosion and sedimentation. In 2010, Hopkinton was designated as a Green Community by the Department of Energy Resources (DOER). The Massachusetts Green Communities Program goals include helping municipalities find clean energy solutions that reduce long-term energy costs and strengthen local economies. DOER selection criteria for a municipality to become a Green Community include providing as-of-right siting in designated locations for renewable/alternative energy generation. Additionally, the Hopkinton Sustainable Green Committee’s mission “is to promote sustainable and environmentally responsible practices in the Town of Hopkinton. The Committee will assist town government, business and residents to implement sustainable policies and practices in the areas of energy, agriculture, conservation and commerce. The Committee will increase the public's awareness of important environmental issues through education and outreach. By fostering environmentally friendly practices in Hopkinton, the Committee aims to enhance the quality of life for our residents, visitors and future generations.” The proposed Project will further the Commonwealth’s and Town of Hopkinton’s commitment to environmental protection through various approaches, including renewable energy sources. 2.4
Compliance with Zoning Bylaw A narrative describing how the proposed Lumber Street Solar Array complies with the applicable requirements of the Zoning Bylaw, specifically Article XXXI, Commercial Solar Photovoltaic Installation, is provided below. 2.4.1 Article XXXI, Commercial Solar Photovoltaic Installation The Project is in full compliance with the Solar Bylaw, Article XXXI, § 210-202, as detailed below. A. A commercial solar photovoltaic installation may be erected, upon the issuance of a special permit by the Planning Board, on a lot containing a minimum of three (3) acres.
Project Narrative
2-4
Special Permit Application CEC Solar #1206, LLC Hopkinton, Massachusetts
The Subject Property is approximately 41.5 acres. The fenced area containing the solar panels will cover approximately 9.2 acres, and the overall Site is approximately 14.1 acres. B. All setback, yard, buffer and screening requirements applicable in the zoning district in which the installation is located shall apply. The proposed use conforms to all setback, yard, buffer, and screening requirements, as depicted on the enclosed plans. As stipulated in the Zoning Bylaw, the setbacks apply to the security fence surrounding the solar panels. C. All security fences surrounding the installations shall be set back from the property line a distance equal to the setback applicable to buildings within the zoning district in which the installation is located. All security fences conform to the required setback limits, as previously discussed. It is understood that the setback requirement is applicable to the security fences and not the solar panels. D. The provisions of Article XX, Site Plan Review, shall not apply to commercial solar photovoltaic installations. Site Plan Review will not be required for the Project. E. The visual impact of the commercial solar photovoltaic installation, including all accessory structures and appurtenances, shall be mitigated. All accessory structures and appurtenances shall be architecturally compatible with each other. Whenever reasonable, structures shall be shielded from view by vegetation and/or joined and clustered to avoid adverse visual impacts. Methods such as the use of landscaping, natural features and fencing may be utilized. There is anticipated to be minimal, if any, visual impact due to the proposed installation. A wooded wetland is located between the proposed Array and the residential houses to the east of the Site, providing an approximately 50foot wide vegetated buffer between these uses. To the west of the Site, the closest point of the Array is set back approximately 100 feet from the property line and more than 240 feet from the residential structure, and will have a buffer of existing trees between the two uses. The property to the north of the Site is a facility for the Hopkinton Sportsmen’s Association, and is currently wooded and undeveloped, and therefore no additional screening for this property is needed. The Array is set back from Lumber Street and will be screened from view by existing vegetation.
Project Narrative
2-5
Special Permit Application CEC Solar #1206, LLC Hopkinton, Massachusetts
The Property is currently undeveloped forested land and a single-family residence. The closest residential structure is approximately 135 feet from the proposed Array. The residential structures surrounding the Site will have the Array shielded from view by heavy vegetation comprised of trees and shrubs. It is anticipated that there will be little to no visual impact to surrounding properties by the proposed Project. F. Lighting shall not be permitted unless required by the Planning Board or by the State Building Code. Where used, lighting shall be directed downward and full cut-off fixtures shall be used. Lighting is not proposed. If it becomes necessary, due to Planning Board or Building Code requirements, it will be directed downward and full cut-off fixtures will be used. G. All utility connections from the commercial solar photovoltaic installation shall be underground unless otherwise specifically permitted otherwise by the Planning Board in the special permit. Electrical transformers and inverters to enable utility interconnections may be above ground if required by the utility provider. The majority of the utility connections will be located underground, however, it is necessary for the interconnection at Lumber Street to be above-ground, as the equipment includes safety equipment for shutting down power to/from the Site as well as metering equipment. Similarly, inverters within the Site must be above-ground for access and maintenance. Therefore, the Applicant respectfully requests that the Planning Board allow the above-ground equipment as depicted on the enclosed plans in the Special Permit. H. Clearing of natural vegetation shall be limited to the minimum necessary for the construction, operation and maintenance of the commercial solar photovoltaic installation except as otherwise prescribed by applicable laws, regulations and bylaws or the special permit. Vegetative clearing has been minimized to the extent practicable for the installation and operation of the Array. Vegetation within the fenced area will be cleared and stumps removed, disturbed areas will be seeded with a native seed mix. Grading has been minimized to the extent practicable. Where grading is not proposed, existing topsoil will remain in place. Where grading is necessary, loam will be imported as needed. Work proposed outside of the fenced area includes grading, clearing of vegetation, and seeding of disturbed areas with a native seed mix.
Project Narrative
2-6
Special Permit Application CEC Solar #1206, LLC Hopkinton, Massachusetts
I. The commercial solar photovoltaic installation owner or operator shall maintain the facility in good condition. Maintenance shall include, but not be limited to, painting, structural repairs, continued compliance with landscaping and screening requirements, and integrity of security measures. The owner or operator shall be responsible for the maintenance of any access roads serving the installation. The commercial solar photovoltaic installation owner will maintain the facility in good condition. The owner/operator will be responsible for the maintenance of any access roads serving the property. 2.4.2 Article XXXI, Section 210-203 Administration 2.4.2.1 Section 210-203.D. Approval Criteria In reviewing any application for special permit pursuant to this Article, the Planning Board shall give due consideration to promoting the public health, safety, convenience and welfare; shall encourage the most appropriate use of land and shall permit no building or use that is injurious, noxious, offensive or detrimental to its neighborhood. Before the Planning Board may issue a special permit, it shall determine each of the following: (1) The commercial solar photovoltaic installation conforms to the provisions of this Article. The proposed solar photovoltaic installation conforms to the provisions of Article XXXI. Please refer to Section 2.4.1 of this application. (2) The commercial solar photovoltaic installation will not be detrimental to the neighborhood or the Town. The proposed installation is not anticipated to be detrimental to the neighborhood or Town, but is anticipated to provide a clean and safe alternative energy source on underutilized land, as detailed herein. (3) Environmental features of the site and surrounding areas are protected and specifically surrounding areas will be protected from the proposed use by provision of adequate surface water drainage.
Project Narrative
2-7
Special Permit Application CEC Solar #1206, LLC Hopkinton, Massachusetts
Site selection and design have been undertaken to impact the natural environment as minimally as possible, as detailed herein. The Project is anticipated to have minimal impact to natural resources on and around the Site, and native landscaping screening and mitigation plantings will mitigate potential impacts. The Site has been designed in compliance with applicable local and state stormwater requirements, and the post- development stormwater runoff rates will not exceed the pre-development rates. Refer to the Stormwater Management Report in Section 4.0 for additional information regarding post-development drainage. (4) The proposed use is in harmony with the general purpose and intent of this Chapter. The proposed use as a solar photovoltaic installation is in harmony with the general purpose and intent of zoning in that it serves to preserve the health and welfare of the public. The proposed Project is anticipated to provide safe, clean alternative energy to the community through energy production without adverse impact to water resources, natural resources, air quality, and visual resources. 2.4.2.2 Section 210-203.F. In reviewing any application for a special permit, the Planning Board shall give due consideration to promoting the public health, safety, convenience and welfare; shall encourage the most appropriate use of land and shall permit no building or use that is injurious, noxious, offensive or detrimental to its neighborhood. The proposed solar installation is anticipated to promote public health, safety, convenience, and welfare by providing the community with a safe, clean alternative energy source with little to no impact on natural resources, including air quality and water resources. The Property is currently underutilized, and the proposed use is a more appropriate use of the land as it is anticipated to provide a safe, clean alternative energy source on surplus land. The benefit derived from the land, both for the property owner, Applicant, and the community, is anticipated to be greater than the existing use by providing clean, safe alternative energy with minimal impacts.
Project Narrative
2-8
Special Permit Application CEC Solar #1206, LLC Hopkinton, Massachusetts
The use proposed is not anticipated to be injurious, noxious, offensive, or detrimental to the neighborhood or Town. The proposed use is anticipated to have a positive impact to the surrounding neighborhood and Town. 2.4.3 Performance Bond The Applicant will work with the Planning Board to determine an appropriate fee to serve as the performance bond, to be conditioned as part of approval.
Project Narrative
2-9
Section 3.0 Abutter Information Certified Abutter List
Section 4.0 Stormwater Management Information Checklist for Stormwater Report Stormwater Management Report
CEC Solar #1206, LLC Stormwater Management Report Hopkinton, Massachusetts 283600RP001A
TABLE OF CONTENTS 1.0
INTRODUCTION .............................................................................................................................................. 1
2.0
PRE-DEVELOPMENT CONDITIONS........................................................................................................... 2
2.1 2.2 2.3 3.0
SITE CONDITIONS ............................................................................................................................................ 2 SOIL DESCRIPTION .......................................................................................................................................... 2 HYDROLOGIC ANALYSIS .................................................................................................................................. 3
POST-DEVELOPMENT CONDITIONS ........................................................................................................ 3
3.1 3.2 3.3 3.4 3.5 3.6
DESIGN STRATEGY ........................................................................................................................................... 3 HYDROLOGIC ANALYSIS .................................................................................................................................. 3 STORMWATER MANAGEMENT CONTROLS SIZING ............................................................................................ 3 COMPLIANCE WITH DEP STORMWATER MANAGEMENT STANDARDS .............................................................. 3 ILLICIT DISCHARGE COMPLIANCE STATEMENT ................................................................................................ 6 DEP’S CHECKLIST FOR A STORMWATER REPORT ............................................................................................ 7
LIST OF APPENDICES APPENDIX A: SOIL DATA APPENDIX B: PRE-DEVELOPMENT HYDROLOGIC ANALYSIS APPENDIX C: POST-DEVELOPMENT HYDROLOGIC ANALYSIS APPENDIX D: DRAWDOWN & RIPRAP-SIZING CALCULATIONS APPENDIX E: SITE OWNER’S MANUAL APPENDIX F: STORMWATER POLLUTION PREVENTION PLAN
Table of Contents
i
CEC Solar #1206, LLC Stormwater Management Report Hopkinton, Massachusetts 283600RP001
1.0
INTRODUCTION
The proposed project includes a stormwater management system designed to mitigate potential impacts the proposed project could have on the existing watershed. Stormwater controls have been proposed to control peak runoff rates, provide water quality, promote groundwater recharge, and sediment removal. The proposed system has been designed to comply with: •
The 2008 Massachusetts Department of Environmental Protection (DEP) Stormwater Management Handbook,
• •
The Massachusetts Wetland Protection Act (310 CMR 10.00), and Town of Hopkinton Wetlands Protection Regulations
The pre- and post-development hydrologic conditions were modeled using HydroCADTM version 10.00 to demonstrate that post-development stormwater runoff rates will be less than or equal to the pre-development rates. Watershed maps with soil types as well as detailed analysis of the model results are also included. The following table summarizes the peak runoff rates and volumes for the pre- and post-development conditions. Table 1: Pre- & Post-development Peak Runoff Rate Comparison, units are in cubic feet per second (cfs).
Storm Event Design Point 1 Design Point 2 Design Point 3
2 Year Pre Post 0.00 0.00 0.22 0.19 0.22 0.14
10 Year Pre Post 0.04 0.00 1.95 1.81 2.35 1.85
25 Year Pre Post 0.27 0.26 4.21 4.10 5.29 5.19
100 Year Pre Post 3.08 2.24 10.21 10.19 13.23 12.24
1
CEC Solar #1206, LLC Stormwater Management Report Hopkinton, Massachusetts 283600RP001
2.0
PRE-DEVELOPMENT CONDITIONS
2.1
Site Conditions The proposed ground-mounted solar facility is located on an approximately 11.4-acre site (the Site) which is partially developed and occupied by a single-family residence. The solar array is proposed within an area that is comprised of predominantly woodland vegetation. The array is accessed off of the existing driveway associated with the dwelling on Lumber Street. The array is approximately centered on a high-point. Runoff from the Site drains to the east and to the west. There are on-site bordering vegetated wetlands (BVW) at the eastern perimeter of the Site as well as a potential vernal pool (PVP) and associated isolated vegetated wetland (IVW) at the southeastern quadrant. There is also a BVW at the western perimeter of the Site (adjacent to Lumber Street). The resource areas at northeastern and western portions of the Site ultimately flow to the north. The southeastern potion of the Site (including the PVP and IVW) flow to the east and south. These three locations described serve as the design points evaluated in the hydrologic analysis. A portion of the Site is within an Outstanding Resource Water (ORW). As described below, the project is proposed in accordance with Massachusetts DEP Stormwater Management Policy.
2.2
Soil Description The Natural Resources Conservation Service (NRCS) Web Soil Survey lists the on-site soils as Canton Fine Sandy Loam, Narragansett Silt Loam, and some areas of Ridgebury Fine Sandy Loam. Canton Fine Sandy Loam is a very deep, well-drained soil on glaciated uplands. The typical soil profile is comprised of layers of fine sandy loam over gravelly fine sandy loam, over gravelly loamy sand. NRCS classifies these soils as Hydrologic Soil Group (HSG) “A” (extremely bouldery) & “B” (extremely stony). Narragansett Silt Loam is a deep, well drained soil on glacial till plains and ground moraine. The typical soil profile is comprised of layers of silt loam over very gravelly loamy sand. NRCS classifies this soil as HSG “A”. Ridgebury Fine Sandy Loam is a very deep, poorly drained to somewhat poorly drained soil on glacial till uplands. The typical soil profile is comprised of layers of fine sandy loam over loamy fine sand, sand, and gravelly coarse sand. NRCS classifies this soil as HSG “D”.
2
CEC Solar #1206, LLC Stormwater Management Report Hopkinton, Massachusetts 283600RP001
2.3
Hydrologic Analysis Sub-catchment areas were delineated based on existing runoff patterns and topographic information. This information is shown on the Pre-Development Conditions Hydrologic Areas Map included in Appendix B. Summaries of each area with respect to Curve Number and Time of Concentration calculations can be found in the model results also in Appendix B.
3.0
POST-DEVELOPMENT CONDITIONS
3.1
Design Strategy The proposed solar array will include stormwater management measures to control peak rates of runoff from the Site. During the design phase of the site layout, consideration was given to minimizing the impact on the existing Site hydrology. To achieve this, grading was minimized to the maximum extent practicable and the Site was designed to match existing terrain where feasible, in order to maintain drainage patterns to maximum extent practicable. Stormwater runoff is directed to the proposed Best Management Practices (BMPs) via overland flow, with diversion berms and conveyance swales, if needed.
3.2
Hydrologic Analysis The established design points used in the pre-development conditions analysis were used in the post-development analysis for direct comparison. The tributary areas and flow paths were modified to reflect post-development conditions. See Appendix C for the Post- Development Conditions Hydrologic Areas Map. Summaries of each area with respect to Curve Number and Time of Concentration calculations can be found in the model results in Appendix C.
3.3
Stormwater Management Controls Sizing Infiltration Basin The three proposed stormwater infiltration basins have been designed to reduce peak runoff rates. All three basins have one to three pipe outlets and a riprap emergency spillway. The basins have been modeled with a conservative infiltration rate of 0.27 inches per hour consistent with HSG “C” soils, though the basins are proposed in areas mapped as HSG “A” & “B”. The basins dewater within 72 hours, as demonstrated by the drawdown calculations in Appendix D.
3.4
Compliance with DEP Stormwater Management Standards The proposed stormwater management system was designed in compliance with the ten (10) DEP Stormwater Management Standards. The following summary provides key information related to the proposed stormwater management system, its design elements, and mitigation measures for potential impacts.
3
CEC Solar #1206, LLC Stormwater Management Report Hopkinton, Massachusetts 283600RP001
STANDARD 1:
No new stormwater conveyance (e.g. outfalls) may discharge untreated stormwater directly to or cause erosion in wetlands or waters of the Commonwealth.
Existing drainage patterns will be maintained. There are no contiguous impervious ground surfaces proposed, with the exception of relatively minor equipment pads. Three infiltration basins have been designed to mitigate stormwater runoff rates associated with the proposed project. Outlets from the basins have been designed to minimize the potential for erosion.
STANDARD 2:
Stormwater management systems shall be designed so that postdevelopment peak discharge rates do not exceed pre-development peak discharge rates.
The stormwater management design will control post-development peak discharge rates for the 2-, 10-, 25-, and 100-year, 24-hour storms so as to maintain pre-development peak discharge rates. Refer to Section 1.0 Introduction for a summary of the peak runoff rates.
STANDARD 3:
Loss of annual recharge to groundwater shall be eliminated or minimized through the use of environmentally sensitive site design, low impact development techniques, stormwater management practices and good operation and maintenance. At a minimum, the annual recharge from the post-development site shall approximate the annual recharge from pre-development conditions based on soil types. This Standard is met when the stormwater management system is designed to infiltrate the required recharge volume as determined in accordance with the Massachusetts Stormwater Handbook.
Groundwater recharge will be maintained as no contiguous impervious ground surfaces are proposed as part of this project, with the exception of two relatively small equipment pads. The stormwater management system includes infiltration basins that will promote groundwater recharge onsite. As a result, annual recharge from the post-development site will approximate the annual recharge from the site under pre-development conditions.
STANDARD 4:
Stormwater management systems shall be designed to remove 80% of the average annual post-construction load of Total Suspended Solids (TSS).
4
CEC Solar #1206, LLC Stormwater Management Report Hopkinton, Massachusetts 283600RP001
The project does not include proposed impervious surfaces requiring treatment, therefore the 80% TSS removal requirement does not apply. A Site Owner’s Manual has been developed to comply with the Long-Term Pollution Prevention Plan (Standard 4) and the Long-Term Operation and Maintenance Plan (Standard 9) requirements of the 2008 Massachusetts Department of Environmental Protection (MassDEP) Stormwater Management Standards. The Manual outlines source control and pollution prevention measures and maintenance requirements of stormwater BMPs associated with the proposed project.
STANDARD 5:
For land uses with higher potential pollutant loads (LUHPPLs), source control and pollution prevention shall be implemented in accordance with the Massachusetts Stormwater Handbook to eliminate or reduce the discharge of stormwater runoff from such land uses to the maximum extent practicable.
The proposed project is not associated with stormwater discharges from land uses with higher potential pollutant loads.
STANDARD 6:
Stormwater discharges to critical areas must utilize certain stormwater management BMPs approved for critical areas. Critical areas are Outstanding Resource Waters, shellfish beds, swimming beaches, coldwater fisheries and recharge areas for public water supplies.
The proposed BMPs are consistent with the Stormwater Management Handbook for use within the ORW critical area. Impervious areas requiring treatment are not proposed as part of this project.
STANDARD 7:
Redevelopment of previously developed sites must meet the Stormwater Management Standards to the maximum extent practicable. However, if it is not practicable to meet all the Standards, new (retrofitted or expanded) stormwater management systems must be designed to improve existing conditions.
The proposed project is new development, and therefore this standard does not apply.
5
CEC Solar #1206, LLC Stormwater Management Report Hopkinton, Massachusetts 283600RP001
STANDARD 8:
A plan to control construction-related impacts during erosion, sedimentation and other pollutant sources during construction and land disturbance activities (construction period erosion, sedimentation, and pollution prevention plan) shall be developed and implemented.
A draft Stormwater Pollution Prevention Plan (SWPPP) has been developed to comply with Section 3 of the NPDES Construction General Permit for Stormwater Discharges; therefore the requirements of Standard 8 are fulfilled.
STANDARD 9:
A Long-Term Operation and Maintenance (O&M) Plan shall be developed and implemented to ensure that stormwater management systems function as designed.
The Site Owner’s Manual complies with the Long-Term Pollution Prevention Plan (Standard 4) and the Long-Term Operation and Maintenance Plan (Standard 9) requirements of the 2008 Massachusetts Department of Environmental Protection (MassDEP) Stormwater Management Standards. The Manual outlines source control and pollution prevention measures and maintenance requirements of the stormwater BMPs associated with the proposed development.
STANDARD 10:
All illicit discharges to the stormwater management system are prohibited.
There will be no illicit discharges to the proposed stormwater management system associated with the proposed project. An Illicit Discharge Compliance Statement is provided on the following page.
3.5
Illicit Discharge Compliance Statement
6
CEC Solar #1206, LLC Stormwater Management Report Hopkinton, Massachusetts 283600RP001
An illicit discharge is any discharge to a municipal separate storm sewer that is not comprised entirely of stormwater, discharges from fire-fighting activities, and certain non-designated non-stormwater discharges. To the best of my knowledge, no detectable illicit discharge exists on site. The site plans included with this report detail the storm sewers that convey stormwater on the site and demonstrate that these systems do not include the entry of an illicit discharge. A Site Owner’s Manual is also included, which contains the Long Term Pollution Plan that outlines measures to prevent future illicit discharges. As the Site Owner, I will ultimately be responsible for implementing the Long Term Pollution Prevention Plan.
Signature:
_______________________________________ Owner’s Name
DEP’s Checklist for a Stormwater Report
7
Massachusetts Department of Environmental Protection Bureau of Resource Protection - Wetlands Program
Checklist for Stormwater Report A. Introduction Important: When filling out forms on the computer, use only the tab key to move your cursor - do not use the return key.
A Stormwater Report must be submitted with the Notice of Intent permit application to document compliance with the Stormwater Management Standards. The following checklist is NOT a substitute for the Stormwater Report (which should provide more substantive and detailed information) but is offered here as a tool to help the applicant organize their Stormwater Management documentation for their Report and for the reviewer to assess this information in a consistent format. As noted in the Checklist, the Stormwater Report must contain the engineering computations and supporting information set forth in Volume 3 of the Massachusetts Stormwater Handbook. The Stormwater Report must be prepared and certified by a Registered Professional Engineer (RPE) licensed in the Commonwealth. The Stormwater Report must include: • The Stormwater Checklist completed and stamped by a Registered Professional Engineer (see page 2) that certifies that the Stormwater Report contains all required submittals.1 This Checklist is to be used as the cover for the completed Stormwater Report. • Applicant/Project Name • Project Address • Name of Firm and Registered Professional Engineer that prepared the Report • Long-Term Pollution Prevention Plan required by Standards 4-6 • Construction Period Pollution Prevention and Erosion and Sedimentation Control Plan required by Standard 82 • Operation and Maintenance Plan required by Standard 9 In addition to all plans and supporting information, the Stormwater Report must include a brief narrative describing stormwater management practices, including environmentally sensitive site design and LID techniques, along with a diagram depicting runoff through the proposed BMP treatment train. Plans are required to show existing and proposed conditions, identify all wetland resource areas, NRCS soil types, critical areas, Land Uses with Higher Potential Pollutant Loads (LUHPPL), and any areas on the site where infiltration rate is greater than 2.4 inches per hour. The Plans shall identify the drainage areas for both existing and proposed conditions at a scale that enables verification of supporting calculations. As noted in the Checklist, the Stormwater Management Report shall document compliance with each of the Stormwater Management Standards as provided in the Massachusetts Stormwater Handbook. The soils evaluation and calculations shall be done using the methodologies set forth in Volume 3 of the Massachusetts Stormwater Handbook. To ensure that the Stormwater Report is complete, applicants are required to fill in the Stormwater Report Checklist by checking the box to indicate that the specified information has been included in the Stormwater Report. If any of the information specified in the checklist has not been submitted, the applicant must provide an explanation. The completed Stormwater Report Checklist and Certification must be submitted with the Stormwater Report.
1
The Stormwater Report may also include the Illicit Discharge Compliance Statement required by Standard 10. If not included in the Stormwater Report, the Illicit Discharge Compliance Statement must be submitted prior to the discharge of stormwater runoff to the post-construction best management practices. 2
For some complex projects, it may not be possible to include the Construction Period Erosion and Sedimentation Control Plan in the Stormwater Report. In that event, the issuing authority has the discretion to issue an Order of Conditions that approves the project and includes a condition requiring the proponent to submit the Construction Period Erosion and Sedimentation Control Plan before commencing any land disturbance activity on the site.
283600swcheck.doc • 04/01/08
Stormwater Report Checklist • Page 1 of 8
Massachusetts Department of Environmental Protection Bureau of Resource Protection - Wetlands Program
Checklist for Stormwater Report Checklist (continued) LID Measures: Stormwater Standards require LID measures to be considered. Document what environmentally sensitive design and LID Techniques were considered during the planning and design of the project: No disturbance to any Wetland Resource Areas Site Design Practices (e.g. clustered development, reduced frontage setbacks) Reduced Impervious Area (Redevelopment Only) Minimizing disturbance to existing trees and shrubs LID Site Design Credit Requested: Credit 1 Credit 2 Credit 3 Use of “country drainage” versus curb and gutter conveyance and pipe Bioretention Cells (includes Rain Gardens) Constructed Stormwater Wetlands (includes Gravel Wetlands designs) Treebox Filter Water Quality Swale Grass Channel Green Roof Other (describe):
Standard 1: No New Untreated Discharges No new untreated discharges Outlets have been designed so there is no erosion or scour to wetlands and waters of the Commonwealth Supporting calculations specified in Volume 3 of the Massachusetts Stormwater Handbook included.
283600swcheck.doc • 04/01/08
Stormwater Report Checklist • Page 3 of 8
Massachusetts Department of Environmental Protection Bureau of Resource Protection - Wetlands Program
Checklist for Stormwater Report Checklist (continued) Standard 2: Peak Rate Attenuation Standard 2 waiver requested because the project is located in land subject to coastal storm flowage and stormwater discharge is to a wetland subject to coastal flooding. Evaluation provided to determine whether off-site flooding increases during the 100-year 24-hour storm. Calculations provided to show that post-development peak discharge rates do not exceed predevelopment rates for the 2-year and 10-year 24-hour storms. If evaluation shows that off-site flooding increases during the 100-year 24-hour storm, calculations are also provided to show that post-development peak discharge rates do not exceed pre-development rates for the 100-year 24hour storm. Standard 3: Recharge Soil Analysis provided. Required Recharge Volume calculation provided. Required Recharge volume reduced through use of the LID site Design Credits. Sizing the infiltration, BMPs is based on the following method: Check the method used. Static
Simple Dynamic
Dynamic Field1
Runoff from all impervious areas at the site discharging to the infiltration BMP. Runoff from all impervious areas at the site is not discharging to the infiltration BMP and calculations are provided showing that the drainage area contributing runoff to the infiltration BMPs is sufficient to generate the required recharge volume. Recharge BMPs have been sized to infiltrate the Required Recharge Volume. Recharge BMPs have been sized to infiltrate the Required Recharge Volume only to the maximum extent practicable for the following reason: Site is comprised solely of C and D soils and/or bedrock at the land surface M.G.L. c. 21E sites pursuant to 310 CMR 40.0000 Solid Waste Landfill pursuant to 310 CMR 19.000 Project is otherwise subject to Stormwater Management Standards only to the maximum extent practicable. Calculations showing that the infiltration BMPs will drain in 72 hours are provided. Property includes a M.G.L. c. 21E site or a solid waste landfill and a mounding analysis is included.
1
80% TSS removal is required prior to discharge to infiltration BMP if Dynamic Field method is used.
283600swcheck.doc • 04/01/08
Stormwater Report Checklist • Page 4 of 8
Massachusetts Department of Environmental Protection Bureau of Resource Protection - Wetlands Program
Checklist for Stormwater Report Checklist (continued) Standard 3: Recharge (continued) The infiltration BMP is used to attenuate peak flows during storms greater than or equal to the 10year 24-hour storm and separation to seasonal high groundwater is less than 4 feet and a mounding analysis is provided. Documentation is provided showing that infiltration BMPs do not adversely impact nearby wetland resource areas. Standard 4: Water Quality The Long-Term Pollution Prevention Plan typically includes the following: • Good housekeeping practices; • Provisions for storing materials and waste products inside or under cover; • Vehicle washing controls; • Requirements for routine inspections and maintenance of stormwater BMPs; • Spill prevention and response plans; • Provisions for maintenance of lawns, gardens, and other landscaped areas; • Requirements for storage and use of fertilizers, herbicides, and pesticides; • Pet waste management provisions; • Provisions for operation and management of septic systems; • Provisions for solid waste management; • Snow disposal and plowing plans relative to Wetland Resource Areas; • Winter Road Salt and/or Sand Use and Storage restrictions; • Street sweeping schedules; • Provisions for prevention of illicit discharges to the stormwater management system; • Documentation that Stormwater BMPs are designed to provide for shutdown and containment in the event of a spill or discharges to or near critical areas or from LUHPPL; • Training for staff or personnel involved with implementing Long-Term Pollution Prevention Plan; • List of Emergency contacts for implementing Long-Term Pollution Prevention Plan. A Long-Term Pollution Prevention Plan is attached to Stormwater Report and is included as an attachment to the Wetlands Notice of Intent. Treatment BMPs subject to the 44% TSS removal pretreatment requirement and the one inch rule for calculating the water quality volume are included, and discharge: is within the Zone II or Interim Wellhead Protection Area is near or to other critical areas is within soils with a rapid infiltration rate (greater than 2.4 inches per hour) involves runoff from land uses with higher potential pollutant loads. The Required Water Quality Volume is reduced through use of the LID site Design Credits. Calculations documenting that the treatment train meets the 80% TSS removal requirement and, if applicable, the 44% TSS removal pretreatment requirement, are provided.
283600swcheck.doc • 04/01/08
Stormwater Report Checklist • Page 5 of 8
Massachusetts Department of Environmental Protection Bureau of Resource Protection - Wetlands Program
Checklist for Stormwater Report Checklist (continued) Standard 4: Water Quality (continued) The BMP is sized (and calculations provided) based on: The ½” or 1” Water Quality Volume or The equivalent flow rate associated with the Water Quality Volume and documentation is provided showing that the BMP treats the required water quality volume. The applicant proposes to use proprietary BMPs, and documentation supporting use of proprietary BMP and proposed TSS removal rate is provided. This documentation may be in the form of the propriety BMP checklist found in Volume 2, Chapter 4 of the Massachusetts Stormwater Handbook and submitting copies of the TARP Report, STEP Report, and/or other third party studies verifying performance of the proprietary BMPs. A TMDL exists that indicates a need to reduce pollutants other than TSS and documentation showing that the BMPs selected are consistent with the TMDL is provided. Standard 5: Land Uses With Higher Potential Pollutant Loads (LUHPPLs) The NPDES Multi-Sector General Permit covers the land use and the Stormwater Pollution Prevention Plan (SWPPP) has been included with the Stormwater Report. The NPDES Multi-Sector General Permit covers the land use and the SWPPP will be submitted prior to the discharge of stormwater to the post-construction stormwater BMPs. The NPDES Multi-Sector General Permit does not cover the land use. LUHPPLs are located at the site and industry specific source control and pollution prevention measures have been proposed to reduce or eliminate the exposure of LUHPPLs to rain, snow, snow melt and runoff, and been included in the long term Pollution Prevention Plan. All exposure has been eliminated. All exposure has not been eliminated and all BMPs selected are on MassDEP LUHPPL list. The LUHPPL has the potential to generate runoff with moderate to higher concentrations of oil and grease (e.g. all parking lots with >1000 vehicle trips per day) and the treatment train includes an oil grit separator, a filtering bioretention area, a sand filter or equivalent. Standard 6: Critical Areas The discharge is near or to a critical area and the treatment train includes only BMPs that MassDEP has approved for stormwater discharges to or near that particular class of critical area. Critical areas and BMPs are identified in the Stormwater Report.
283600swcheck.doc • 04/01/08
Stormwater Report Checklist • Page 6 of 8
Massachusetts Department of Environmental Protection Bureau of Resource Protection - Wetlands Program
Checklist for Stormwater Report Checklist (continued) Standard 7: Redevelopments and Other Projects Subject to the Standards only to the maximum extent practicable The project is subject to the Stormwater Management Standards only to the maximum Extent Practicable as a: Limited Project Small Residential Projects: 5-9 single family houses or 5-9 units in a multi-family development provided there is no discharge that may potentially affect a critical area. Small Residential Projects: 2-4 single family houses or 2-4 units in a multi-family development with a discharge to a critical area Marina and/or boatyard provided the hull painting, service and maintenance areas are protected from exposure to rain, snow, snow melt and runoff Bike Path and/or Foot Path Redevelopment Project Redevelopment portion of mix of new and redevelopment. Certain standards are not fully met (Standard No. 1, 8, 9, and 10 must always be fully met) and an explanation of why these standards are not met is contained in the Stormwater Report. The project involves redevelopment and a description of all measures that have been taken to improve existing conditions is provided in the Stormwater Report. The redevelopment checklist found in Volume 2 Chapter 3 of the Massachusetts Stormwater Handbook may be used to document that the proposed stormwater management system (a) complies with Standards 2, 3 and the pretreatment and structural BMP requirements of Standards 4-6 to the maximum extent practicable and (b) improves existing conditions. Standard 8: Construction Period Pollution Prevention and Erosion and Sedimentation Control A Construction Period Pollution Prevention and Erosion and Sedimentation Control Plan must include the following information: • • • • • • • • • • • • • •
Narrative; Construction Period Operation and Maintenance Plan; Names of Persons or Entity Responsible for Plan Compliance; Construction Period Pollution Prevention Measures; Erosion and Sedimentation Control Plan Drawings; Detail drawings and specifications for erosion control BMPs, including sizing calculations; Vegetation Planning; Site Development Plan; Construction Sequencing Plan; Sequencing of Erosion and Sedimentation Controls; Operation and Maintenance of Erosion and Sedimentation Controls; Inspection Schedule; Maintenance Schedule; Inspection and Maintenance Log Form.
A Construction Period Pollution Prevention and Erosion and Sedimentation Control Plan containing the information set forth above has been included in the Stormwater Report.
283600swcheck.doc • 04/01/08
Stormwater Report Checklist • Page 7 of 8
Massachusetts Department of Environmental Protection Bureau of Resource Protection - Wetlands Program
Checklist for Stormwater Report Checklist (continued) Standard 8: Construction Period Pollution Prevention and Erosion and Sedimentation Control (continued) The project is highly complex and information is included in the Stormwater Report that explains why it is not possible to submit the Construction Period Pollution Prevention and Erosion and Sedimentation Control Plan with the application. A Construction Period Pollution Prevention and Erosion and Sedimentation Control has not been included in the Stormwater Report but will be submitted before land disturbance begins. The project is not covered by a NPDES Construction General Permit. The project is covered by a NPDES Construction General Permit and a copy of the SWPPP is in the Stormwater Report. The project is covered by a NPDES Construction General Permit but no SWPPP been submitted. The SWPPP will be submitted BEFORE land disturbance begins. Standard 9: Operation and Maintenance Plan The Post Construction Operation and Maintenance Plan is included in the Stormwater Report and includes the following information: Name of the stormwater management system owners; Party responsible for operation and maintenance; Schedule for implementation of routine and non-routine maintenance tasks; Plan showing the location of all stormwater BMPs maintenance access areas; Description and delineation of public safety features; Estimated operation and maintenance budget; and Operation and Maintenance Log Form. The responsible party is not the owner of the parcel where the BMP is located and the Stormwater Report includes the following submissions: A copy of the legal instrument (deed, homeowner’s association, utility trust or other legal entity) that establishes the terms of and legal responsibility for the operation and maintenance of the project site stormwater BMPs; A plan and easement deed that allows site access for the legal entity to operate and maintain BMP functions. Standard 10: Prohibition of Illicit Discharges The Long-Term Pollution Prevention Plan includes measures to prevent illicit discharges; An Illicit Discharge Compliance Statement is attached; NO Illicit Discharge Compliance Statement is attached but will be submitted prior to the discharge of any stormwater to post-construction BMPs.
283600swcheck.doc • 04/01/08
Stormwater Report Checklist • Page 8 of 8
Appendix A Soil Data
290600
290700
290800
290900
291000
291100
291200
291300
291400
291500
291600 4676200
290500
71° 31' 26'' W
71° 32' 16'' W
Hydrologic Soil Group—Middlesex County, Massachusetts (2836.00)
42° 12' 37'' N
4674800
4674800
4674900
4674900
4675000
4675000
4675100
4675100
4675200
4675200
4675300
4675300
4675400
4675400
4675500
4675500
4675600
4675600
4675700
4675700
4675800
4675800
4675900
4675900
4676000
4676000
4676100
4676100
4676200
42° 12' 37'' N
4674700
Soil Map may not be valid at this scale.
42° 11' 47'' N
290600
290700
290800
290900
291000
291100
291200
Map Scale: 1:7,480 if printed on A portrait (8.5" x 11") sheet.
N
Meters 600 Feet 0 350 700 1400 2100 Map projection: Web Mercator Corner coordinates: WGS84 Edge tics: UTM Zone 19N WGS84 0
100
Natural Resources Conservation Service
200
400
Web Soil Survey National Cooperative Soil Survey
291300
291400
291500
291600 71° 31' 26'' W
71° 32' 16'' W
290500
1/6/2017 Page 1 of 5
42° 11' 47'' N
Hydrologic Soil Group—Middlesex County, Massachusetts (2836.00)
MAP LEGEND Area of Interest (AOI) Area of Interest (AOI) Soils Soil Rating Polygons A A/D B B/D C C/D D Not rated or not available Soil Rating Lines A
MAP INFORMATION The soil surveys that comprise your AOI were mapped at 1:25,000.
C C/D D
Warning: Soil Map may not be valid at this scale.
Not rated or not available
Enlargement of maps beyond the scale of mapping can cause misunderstanding of the detail of mapping and accuracy of soil line placement. The maps do not show the small areas of contrasting soils that could have been shown at a more detailed scale.
Water Features Streams and Canals Transportation Rails Interstate Highways US Routes Major Roads Local Roads Background Aerial Photography
A/D B
Please rely on the bar scale on each map sheet for map measurements. Source of Map: Natural Resources Conservation Service Web Soil Survey URL: Coordinate System: Web Mercator (EPSG:3857) Maps from the Web Soil Survey are based on the Web Mercator projection, which preserves direction and shape but distorts distance and area. A projection that preserves area, such as the Albers equal-area conic projection, should be used if more accurate calculations of distance or area are required. This product is generated from the USDA-NRCS certified data as of the version date(s) listed below.
B/D
Soil Survey Area: Middlesex County, Massachusetts Survey Area Data: Version 16, Sep 14, 2016
C C/D
Soil map units are labeled (as space allows) for map scales 1:50,000 or larger.
D
Date(s) aerial images were photographed: 28, 2014
Not rated or not available Soil Rating Points
Sep 12, 2014—Sep
The orthophoto or other base map on which the soil lines were compiled and digitized probably differs from the background imagery displayed on these maps. As a result, some minor shifting of map unit boundaries may be evident.
A A/D B B/D
Natural Resources Conservation Service
Web Soil Survey National Cooperative Soil Survey
1/6/2017 Page 2 of 5
Hydrologic Soil Group—Middlesex County, Massachusetts
2836.00
Hydrologic Soil Group
Hydrologic Soil Group— Summary by Map Unit — Middlesex County, Massachusetts (MA017) Map unit symbol
Map unit name
Rating
51A
Swansea muck, 0 to 1 percent slopes
B/D
71B
Ridgebury fine sandy loam, 3 to 8 percent slopes, extremely stony
73B
Acres in AOI
Percent of AOI 4.2
1.6%
D
20.6
7.9%
Whitman fine sandy loam, 0 to 3 percent slopes, extremely stony
D
27.3
10.5%
106C
Narragansett-HollisRock outcrop complex, 3 to 15 percent slopes
A
9.9
3.8%
302B
Montauk fine sandy loam, 0 to 8 percent slopes, extremely stony
C
0.4
0.1%
302D
Montauk fine sandy C loam, 15 to 35 percent slopes, extremely stony
5.0
1.9%
307B
Paxton fine sandy loam, C 0 to 8 percent slopes, extremely stony
15.2
5.9%
307C
Paxton fine sandy loam, C 8 to 15 percent slopes, extremely stony
1.7
0.6%
317B
Scituate fine sandy loam, 3 to 8 percent slopes, extremely stony
11.7
4.5%
336B
Rainbow silt loam, 3 to 8 C/D percent slopes, very stony
1.6
0.6%
416B
Narragansett silt loam, 3 A to 8 percent slopes, very stony
31.9
12.3%
416C
Narragansett silt loam, 8 A to 15 percent slopes, very stony
56.9
21.9%
422B
Canton fine sandy loam, B 0 to 8 percent slopes, extremely stony
41.3
15.9%
Natural Resources Conservation Service
D
Web Soil Survey National Cooperative Soil Survey
1/6/2017 Page 3 of 5
Hydrologic Soil Group—Middlesex County, Massachusetts
2836.00
Hydrologic Soil Group— Summary by Map Unit — Middlesex County, Massachusetts (MA017) Map unit symbol
Map unit name
Rating
Acres in AOI
Percent of AOI
424B
Canton fine sandy loam, A 3 to 8 percent slopes, extremely bouldery
16.8
6.5%
424C
Canton fine sandy loam, A 8 to 15 percent slopes, extremely bouldery
8.3
3.2%
424D
Canton fine sandy loam, A 15 to 25 percent slopes, extremely bouldery
6.9
2.7%
654
Udorthents, loamy
0.1
0.0%
259.7
100.0%
Totals for Area of Interest
Description Hydrologic soil groups are based on estimates of runoff potential. Soils are assigned to one of four groups according to the rate of water infiltration when the soils are not protected by vegetation, are thoroughly wet, and receive precipitation from long-duration storms. The soils in the United States are assigned to four groups (A, B, C, and D) and three dual classes (A/D, B/D, and C/D). The groups are defined as follows: Group A. Soils having a high infiltration rate (low runoff potential) when thoroughly wet. These consist mainly of deep, well drained to excessively drained sands or gravelly sands. These soils have a high rate of water transmission. Group B. Soils having a moderate infiltration rate when thoroughly wet. These consist chiefly of moderately deep or deep, moderately well drained or well drained soils that have moderately fine texture to moderately coarse texture. These soils have a moderate rate of water transmission. Group C. Soils having a slow infiltration rate when thoroughly wet. These consist chiefly of soils having a layer that impedes the downward movement of water or soils of moderately fine texture or fine texture. These soils have a slow rate of water transmission. Group D. Soils having a very slow infiltration rate (high runoff potential) when thoroughly wet. These consist chiefly of clays that have a high shrink-swell potential, soils that have a high water table, soils that have a claypan or clay layer at or near the surface, and soils that are shallow over nearly impervious material. These soils have a very slow rate of water transmission. If a soil is assigned to a dual hydrologic group (A/D, B/D, or C/D), the first letter is for drained areas and the second is for undrained areas. Only the soils that in their natural condition are in group D are assigned to dual classes.
Natural Resources Conservation Service
Web Soil Survey National Cooperative Soil Survey
1/6/2017 Page 4 of 5
Appendix B Pre-Development Hydrologic Analysis
Extreme Precipitation Tables: 42.201°N, 71.531°W
Page 1 of 1
Extreme Precipitation Tables Northeast Regional Climate Center Data represents point estimates calculated from partial duration series. All precipitation amounts are displayed in inches. Smoothing State Location Longitude Latitude Elevation Date/Time
Yes Massachusetts 71.531 degrees West 42.201 degrees North 0 feet Thu, 23 Mar 2017 17:26:16 -0400
Extreme Precipitation Estimates 1yr 2yr 5yr 10yr 25yr 50yr 100yr 200yr 500yr
5min 0.29 0.35 0.42 0.47 0.56 0.63 0.72 0.82 0.99
10min 0.44 0.54 0.65 0.74 0.89 1.01 1.17 1.34 1.63
15min 0.54 0.67 0.81 0.93 1.13 1.29 1.51 1.74 2.13
30min 0.71 0.89 1.09 1.27 1.55 1.81 2.13 2.49 3.09
60min 120min 1hr 2hr 3hr 6hr 12hr 24hr 48hr 0.89 1.13 1yr 0.77 1.07 1.31 1.65 2.10 2.68 2.92 1yr 1.11 1.40 2yr 0.96 1.29 1.63 2.04 2.57 3.23 3.52 2yr 1.39 1.77 5yr 1.20 1.61 2.06 2.59 3.24 4.06 4.48 5yr 1.65 2.11 10yr 1.42 1.90 2.46 3.10 3.88 4.84 5.38 10yr 2.06 2.66 25yr 1.78 2.36 3.11 3.93 4.91 6.09 6.87 25yr 2.44 3.19 50yr 2.11 2.79 3.74 4.72 5.88 7.26 8.26 50yr 2.90 3.80 100yr 2.50 3.30 4.47 5.64 7.02 8.66 9.95 100yr 3.44 4.54 200yr 2.97 3.90 5.35 6.76 8.40 10.32 11.98 200yr 4.32 5.75 500yr 3.73 4.87 6.79 8.58 10.65 13.04 15.32 500yr
1day 2.37 2.86 3.59 4.28 5.39 6.42 7.66 9.14 11.54
2day 2.81 3.38 4.31 5.18 6.60 7.95 9.56 11.52 14.73
4day 3.25 3.89 4.93 5.91 7.50 8.99 10.79 12.94 16.47
7day 3.92 4.62 5.83 6.95 8.78 10.47 12.50 14.93 18.89
10day 4.56 5.25 6.52 7.68 9.54 11.26 13.28 15.67 19.51
1yr 2yr 5yr 10yr 25yr 50yr 100yr 200yr 500yr
Lower Confidence Limits 1yr 2yr 5yr 10yr 25yr 50yr 100yr 200yr 500yr
5min 0.23 0.34 0.38 0.42 0.49 0.54 0.59 0.66 0.75
10min 0.35 0.53 0.59 0.65 0.74 0.82 0.90 0.99 1.12
15min 0.43 0.65 0.73 0.81 0.92 1.02 1.13 1.25 1.44
30min 0.58 0.88 1.00 1.13 1.31 1.46 1.63 1.81 2.09
60min 120min 1hr 2hr 3hr 6hr 12hr 24hr 48hr 0.71 0.94 1yr 0.61 0.92 1.07 1.42 1.85 2.35 2.70 1yr 1.08 1.27 2yr 0.93 1.24 1.45 1.91 2.44 3.13 3.40 2yr 1.28 1.52 5yr 1.10 1.48 1.72 2.25 2.86 3.73 4.12 5yr 1.45 1.73 10yr 1.26 1.69 1.95 2.55 3.22 4.27 4.76 10yr 1.73 2.05 25yr 1.49 2.01 2.31 3.02 3.78 5.11 5.72 25yr 1.97 2.33 50yr 1.70 2.28 2.62 3.42 4.26 5.85 6.59 50yr 2.23 2.65 100yr 1.93 2.59 2.97 3.88 4.81 6.71 7.57 100yr 2.53 3.02 200yr 2.18 2.96 3.38 4.42 5.44 7.70 8.68 200yr 2.97 3.60 500yr 2.56 3.52 3.99 5.25 6.42 9.26 10.39 500yr
1day 2.08 2.77 3.31 3.78 4.53 5.18 5.94 6.81 8.19
2day 2.60 3.27 3.97 4.57 5.50 6.34 7.28 8.35 9.99
4day 2.95 3.76 4.54 5.24 6.34 7.33 8.48 9.80 11.90
7day 3.58 4.46 5.36 6.14 7.36 8.43 9.70 11.14 13.38
10day 4.11 5.08 6.02 6.84 8.07 9.18 10.44 11.89 14.14
1yr 2yr 5yr 10yr 25yr 50yr 100yr 200yr 500yr
Upper Confidence Limits 1yr 2yr 5yr 10yr 25yr 50yr 100yr 200yr 500yr
5min 0.32 0.37 0.45 0.54 0.69 0.82 0.99 1.19 1.55
10min 0.49 0.56 0.70 0.83 1.04 1.25 1.50 1.80 2.30
15min 0.60 0.69 0.87 1.03 1.30 1.56 1.88 2.28 2.96
30min 0.81 0.94 1.19 1.44 1.86 2.24 2.71 3.30 4.30
60min 120min 1hr 2hr 3hr 6hr 12hr 24hr 48hr 1.00 1.19 1yr 0.86 1.17 1.37 1.76 2.30 2.93 3.16 1yr 1.16 1.36 2yr 1.00 1.33 1.57 2.04 2.60 3.36 3.66 2yr 1.51 1.78 5yr 1.31 1.74 2.04 2.62 3.31 4.39 4.86 5yr 1.86 2.19 10yr 1.60 2.14 2.50 3.18 3.96 5.39 6.06 10yr 2.44 2.88 25yr 2.11 2.82 3.27 4.08 5.05 7.07 8.12 25yr 3.01 3.54 50yr 2.60 3.46 4.02 4.94 6.06 8.69 10.12 50yr 3.72 4.36 100yr 3.21 4.26 4.93 5.98 7.28 10.67 12.66 100yr 4.60 5.37 200yr 3.97 5.25 6.07 7.24 8.73 13.10 15.85 200yr 6.11 7.08 500yr 5.28 6.92 7.98 9.32 11.12 17.21 21.36 500yr
1day 2.60 2.97 3.89 4.77 6.26 7.69 9.44 11.59 15.23
2day 3.04 3.52 4.67 5.83 7.80 9.73 12.18 15.24 20.54
4day 3.53 4.05 5.37 6.65 8.85 10.98 13.64 16.93 22.55
7day 4.23 4.80 6.35 7.84 10.39 12.84 15.88 19.65 26.05
10day 4.89 5.44 7.04 8.58 11.15 13.62 16.61 20.23 26.30
1yr 2yr 5yr 10yr 25yr 50yr 100yr 200yr 500yr
Powered by ACIS
file:///G:/Projdata/2836/Transfers/In/NRCC/2017-03-23/output.htm
4/24/2017
Hydrologic Soil Group—Middlesex County, Massachusetts
2836.00
Rating Options Aggregation Method: Dominant Condition Component Percent Cutoff: None Specified Tie-break Rule: Higher
Natural Resources Conservation Service
Web Soil Survey National Cooperative Soil Survey
1/6/2017 Page 5 of 5
10R 1S E-DP-1 E-DA-1
2S 30R
3S
E-DP-3
E-DA-3
E-DA-2
20R E-DP-2
PRE-DEVELOPMENT
Subcat
Reach
Pond
Link
Routing Diagram for 283600HC001A Prepared by Microsoft, Printed 4/24/2017 HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
2836.00 Pre-Development
283600HC001A Prepared by Microsoft HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Area Listing (selected nodes) Area (acres)
CN
0.081 2.223 0.021 0.077 0.349 0.066 0.127 11.144 9.228 0.256 23.572
39 61 80 98 98 98 98 30 55 77 45
Description (subcatchment-numbers) >75% Grass cover, Good, HSG A (3S) >75% Grass cover, Good, HSG B (2S, 3S) >75% Grass cover, Good, HSG D (3S) Paved parking, HSG A (3S) Paved parking, HSG B (2S, 3S) Paved parking, HSG D (2S, 3S) Unconnected roofs, HSG B (2S, 3S) Woods, Good, HSG A (1S, 2S, 3S) Woods, Good, HSG B (1S, 2S, 3S) Woods, Good, HSG D (1S, 2S, 3S) TOTAL AREA
Printed 4/24/2017 Page 2
2836.00 Pre-Development
283600HC001A Prepared by Microsoft HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Soil Listing (selected nodes) Area (acres)
Soil Group
Subcatchment Numbers
11.302 11.927 0.000 0.343 0.000 23.572
HSG A HSG B HSG C HSG D Other
1S, 2S, 3S 1S, 2S, 3S 1S, 2S, 3S TOTAL AREA
Printed 4/24/2017 Page 3
2836.00 Pre-Development
283600HC001A Printed 4/24/2017 Page 4
Prepared by Microsoft HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Ground Covers (selected nodes) HSG-A (acres)
HSG-B (acres)
HSG-C (acres)
HSG-D (acres)
Other (acres)
Total (acres)
Ground Cover
Subcatchment Numbers
0.081 0.077 0.000 11.144
2.223 0.349 0.127 9.228
0.000 0.000 0.000 0.000
0.021 0.066 0.000 0.256
0.000 0.000 0.000 0.000
2.325 0.492 0.127 20.628
>75% Grass cover, Good Paved parking Unconnected roofs Woods, Good
2S, 3S 2S, 3S 2S, 3S 1S, 2S, 3S
11.302
11.927
0.000
0.343
0.000
23.572
TOTAL AREA
2836.00 Pre-Development
Type III 24-hr 2-YR NRCC Rainfall=3.22"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Printed 4/24/2017 Page 5
Summary for Subcatchment 1S: E-DA-1 [45] Hint: Runoff=Zero Runoff
=
0.00 cfs @
0.00 hrs, Volume=
0.000 af, Depth= 0.00"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 2-YR NRCC Rainfall=3.22" Area (ac) 7.407 1.544 0.001 8.952 8.952
CN 30 55 77 34
Description Woods, Good, HSG A Woods, Good, HSG B Woods, Good, HSG D Weighted Average 100.00% Pervious Area
Tc Length Slope (min) (feet) (ft/ft) 13.0 50 0.0690
Velocity (ft/sec) 0.06
11.9
272
0.0231
0.38
6.4
308
0.1045
0.81
31.3
630
Total
Capacity (cfs)
Description Sheet Flow, Sheet Flow Woods: Dense underbrush n= 0.800 P2= 3.23" Shallow Concentrated Flow, Shallow Concentrated Flow 1 Forest w/Heavy Litter Kv= 2.5 fps Shallow Concentrated Flow, Shallow Concentrated Flow 2 Forest w/Heavy Litter Kv= 2.5 fps
Summary for Subcatchment 2S: E-DA-2 Runoff
=
0.22 cfs @ 12.95 hrs, Volume=
0.093 af, Depth> 0.17"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 2-YR NRCC Rainfall=3.22" Area (ac) 0.105 0.053 0.056 1.417 3.482 0.057 1.229 6.399 6.185 0.214 0.056
CN 98 98 98 30 55 77 61 52
Description Paved parking, HSG B Paved parking, HSG D Unconnected roofs, HSG B Woods, Good, HSG A Woods, Good, HSG B Woods, Good, HSG D >75% Grass cover, Good, HSG B Weighted Average 96.66% Pervious Area 3.34% Impervious Area 26.17% Unconnected
2836.00 Pre-Development
Type III 24-hr 2-YR NRCC Rainfall=3.22"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Tc Length Slope (min) (feet) (ft/ft) 15.5 50 0.0450
Velocity (ft/sec) 0.05
13.2
299
0.0229
0.38
3.6
168
0.0954
0.77
5.8
165
0.0364
0.48
38.1
682
Total
Capacity (cfs)
Printed 4/24/2017 Page 6
Description Sheet Flow, Sheet Flow Woods: Dense underbrush n= 0.800 P2= 3.23" Shallow Concentrated Flow, Shallow Concentrated Flow 1 Forest w/Heavy Litter Kv= 2.5 fps Shallow Concentrated Flow, Shallow Concentrated Flow 2 Forest w/Heavy Litter Kv= 2.5 fps Shallow Concentrated Flow, Shallow Concentrated Flow 3 Forest w/Heavy Litter Kv= 2.5 fps
Summary for Subcatchment 3S: E-DA-3 Runoff
=
0.22 cfs @ 12.97 hrs, Volume=
0.104 af, Depth> 0.15"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 2-YR NRCC Rainfall=3.22" Area (ac) 0.077 0.244 0.013 0.071 2.320 4.202 0.198 0.081 0.994 0.021 8.221 7.816 0.405 0.071
CN 98 98 98 98 30 55 77 39 61 80 51
Description Paved parking, HSG A Paved parking, HSG B Paved parking, HSG D Unconnected roofs, HSG B Woods, Good, HSG A Woods, Good, HSG B Woods, Good, HSG D >75% Grass cover, Good, HSG A >75% Grass cover, Good, HSG B >75% Grass cover, Good, HSG D Weighted Average 95.07% Pervious Area 4.93% Impervious Area 17.53% Unconnected
Tc Length Slope (min) (feet) (ft/ft) 14.8 50 0.0500
Velocity (ft/sec) 0.06
12.1
347
0.0363
0.48
7.0
301
0.0830
0.72
33.9
698
Total
Capacity (cfs)
Description Sheet Flow, Sheet Flow Woods: Dense underbrush n= 0.800 P2= 3.23" Shallow Concentrated Flow, Shallow Concentrated Flow 1 Forest w/Heavy Litter Kv= 2.5 fps Shallow Concentrated Flow, Shallow Concentrated Flow 2 Forest w/Heavy Litter Kv= 2.5 fps
2836.00 Pre-Development
Type III 24-hr 2-YR NRCC Rainfall=3.22"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Printed 4/24/2017 Page 7
Summary for Reach 10R: E-DP-1 [40] Hint: Not Described (Outflow=Inflow) Inflow Area = Inflow = Outflow =
8.952 ac, 0.00% Impervious, Inflow Depth = 0.00" for 2-YR NRCC event 0.00 cfs @ 0.00 hrs, Volume= 0.000 af 0.00 cfs @ 0.00 hrs, Volume= 0.000 af, Atten= 0%, Lag= 0.0 min
Routing by Stor-Ind+Trans method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs
Summary for Reach 20R: E-DP-2 [40] Hint: Not Described (Outflow=Inflow) Inflow Area = Inflow = Outflow =
6.399 ac, 3.34% Impervious, Inflow Depth > 0.17" for 2-YR NRCC event 0.22 cfs @ 12.95 hrs, Volume= 0.093 af 0.22 cfs @ 12.95 hrs, Volume= 0.093 af, Atten= 0%, Lag= 0.0 min
Routing by Stor-Ind+Trans method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs
Summary for Reach 30R: E-DP-3 [40] Hint: Not Described (Outflow=Inflow) Inflow Area = Inflow = Outflow =
8.221 ac, 4.93% Impervious, Inflow Depth > 0.15" for 2-YR NRCC event 0.22 cfs @ 12.97 hrs, Volume= 0.104 af 0.22 cfs @ 12.97 hrs, Volume= 0.104 af, Atten= 0%, Lag= 0.0 min
Routing by Stor-Ind+Trans method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs
2836.00 Pre-Development
Type III 24-hr 10-YR NRCC Rainfall=4.81"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Printed 4/24/2017 Page 8
Summary for Subcatchment 1S: E-DA-1 Runoff
=
0.04 cfs @ 17.18 hrs, Volume=
0.030 af, Depth> 0.04"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 10-YR NRCC Rainfall=4.81" Area (ac) 7.407 1.544 0.001 8.952 8.952
CN 30 55 77 34
Description Woods, Good, HSG A Woods, Good, HSG B Woods, Good, HSG D Weighted Average 100.00% Pervious Area
Tc Length Slope (min) (feet) (ft/ft) 13.0 50 0.0690
Velocity (ft/sec) 0.06
11.9
272
0.0231
0.38
6.4
308
0.1045
0.81
31.3
630
Total
Capacity (cfs)
Description Sheet Flow, Sheet Flow Woods: Dense underbrush n= 0.800 P2= 3.23" Shallow Concentrated Flow, Shallow Concentrated Flow 1 Forest w/Heavy Litter Kv= 2.5 fps Shallow Concentrated Flow, Shallow Concentrated Flow 2 Forest w/Heavy Litter Kv= 2.5 fps
Summary for Subcatchment 2S: E-DA-2 Runoff
=
1.95 cfs @ 12.67 hrs, Volume=
0.379 af, Depth> 0.71"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 10-YR NRCC Rainfall=4.81" Area (ac) 0.105 0.053 0.056 1.417 3.482 0.057 1.229 6.399 6.185 0.214 0.056
CN 98 98 98 30 55 77 61 52
Description Paved parking, HSG B Paved parking, HSG D Unconnected roofs, HSG B Woods, Good, HSG A Woods, Good, HSG B Woods, Good, HSG D >75% Grass cover, Good, HSG B Weighted Average 96.66% Pervious Area 3.34% Impervious Area 26.17% Unconnected
2836.00 Pre-Development
Type III 24-hr 10-YR NRCC Rainfall=4.81"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Tc Length Slope (min) (feet) (ft/ft) 15.5 50 0.0450
Velocity (ft/sec) 0.05
13.2
299
0.0229
0.38
3.6
168
0.0954
0.77
5.8
165
0.0364
0.48
38.1
682
Total
Capacity (cfs)
Printed 4/24/2017 Page 9
Description Sheet Flow, Sheet Flow Woods: Dense underbrush n= 0.800 P2= 3.23" Shallow Concentrated Flow, Shallow Concentrated Flow 1 Forest w/Heavy Litter Kv= 2.5 fps Shallow Concentrated Flow, Shallow Concentrated Flow 2 Forest w/Heavy Litter Kv= 2.5 fps Shallow Concentrated Flow, Shallow Concentrated Flow 3 Forest w/Heavy Litter Kv= 2.5 fps
Summary for Subcatchment 3S: E-DA-3 Runoff
=
2.35 cfs @ 12.62 hrs, Volume=
0.451 af, Depth> 0.66"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 10-YR NRCC Rainfall=4.81" Area (ac) 0.077 0.244 0.013 0.071 2.320 4.202 0.198 0.081 0.994 0.021 8.221 7.816 0.405 0.071
CN 98 98 98 98 30 55 77 39 61 80 51
Description Paved parking, HSG A Paved parking, HSG B Paved parking, HSG D Unconnected roofs, HSG B Woods, Good, HSG A Woods, Good, HSG B Woods, Good, HSG D >75% Grass cover, Good, HSG A >75% Grass cover, Good, HSG B >75% Grass cover, Good, HSG D Weighted Average 95.07% Pervious Area 4.93% Impervious Area 17.53% Unconnected
Tc Length Slope (min) (feet) (ft/ft) 14.8 50 0.0500
Velocity (ft/sec) 0.06
12.1
347
0.0363
0.48
7.0
301
0.0830
0.72
33.9
698
Total
Capacity (cfs)
Description Sheet Flow, Sheet Flow Woods: Dense underbrush n= 0.800 P2= 3.23" Shallow Concentrated Flow, Shallow Concentrated Flow 1 Forest w/Heavy Litter Kv= 2.5 fps Shallow Concentrated Flow, Shallow Concentrated Flow 2 Forest w/Heavy Litter Kv= 2.5 fps
2836.00 Pre-Development
Type III 24-hr 10-YR NRCC Rainfall=4.81"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Printed 4/24/2017 Page 10
Summary for Reach 10R: E-DP-1 [40] Hint: Not Described (Outflow=Inflow) Inflow Area = Inflow = Outflow =
8.952 ac, 0.00% Impervious, Inflow Depth > 0.04" for 10-YR NRCC event 0.04 cfs @ 17.18 hrs, Volume= 0.030 af 0.04 cfs @ 17.18 hrs, Volume= 0.030 af, Atten= 0%, Lag= 0.0 min
Routing by Stor-Ind+Trans method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs
Summary for Reach 20R: E-DP-2 [40] Hint: Not Described (Outflow=Inflow) Inflow Area = Inflow = Outflow =
6.399 ac, 3.34% Impervious, Inflow Depth > 0.71" for 10-YR NRCC event 1.95 cfs @ 12.67 hrs, Volume= 0.379 af 1.95 cfs @ 12.67 hrs, Volume= 0.379 af, Atten= 0%, Lag= 0.0 min
Routing by Stor-Ind+Trans method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs
Summary for Reach 30R: E-DP-3 [40] Hint: Not Described (Outflow=Inflow) Inflow Area = Inflow = Outflow =
8.221 ac, 4.93% Impervious, Inflow Depth > 0.66" for 10-YR NRCC event 2.35 cfs @ 12.62 hrs, Volume= 0.451 af 2.35 cfs @ 12.62 hrs, Volume= 0.451 af, Atten= 0%, Lag= 0.0 min
Routing by Stor-Ind+Trans method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs
2836.00 Pre-Development
Type III 24-hr 25-YR NRCC Rainfall=6.05"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Printed 4/24/2017 Page 11
Summary for Subcatchment 1S: E-DA-1 Runoff
=
0.27 cfs @ 13.97 hrs, Volume=
0.159 af, Depth> 0.21"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 25-YR NRCC Rainfall=6.05" Area (ac) 7.407 1.544 0.001 8.952 8.952
CN 30 55 77 34
Description Woods, Good, HSG A Woods, Good, HSG B Woods, Good, HSG D Weighted Average 100.00% Pervious Area
Tc Length Slope (min) (feet) (ft/ft) 13.0 50 0.0690
Velocity (ft/sec) 0.06
11.9
272
0.0231
0.38
6.4
308
0.1045
0.81
31.3
630
Total
Capacity (cfs)
Description Sheet Flow, Sheet Flow Woods: Dense underbrush n= 0.800 P2= 3.23" Shallow Concentrated Flow, Shallow Concentrated Flow 1 Forest w/Heavy Litter Kv= 2.5 fps Shallow Concentrated Flow, Shallow Concentrated Flow 2 Forest w/Heavy Litter Kv= 2.5 fps
Summary for Subcatchment 2S: E-DA-2 Runoff
=
4.21 cfs @ 12.62 hrs, Volume=
0.693 af, Depth> 1.30"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 25-YR NRCC Rainfall=6.05" Area (ac) 0.105 0.053 0.056 1.417 3.482 0.057 1.229 6.399 6.185 0.214 0.056
CN 98 98 98 30 55 77 61 52
Description Paved parking, HSG B Paved parking, HSG D Unconnected roofs, HSG B Woods, Good, HSG A Woods, Good, HSG B Woods, Good, HSG D >75% Grass cover, Good, HSG B Weighted Average 96.66% Pervious Area 3.34% Impervious Area 26.17% Unconnected
2836.00 Pre-Development
Type III 24-hr 25-YR NRCC Rainfall=6.05"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Tc Length Slope (min) (feet) (ft/ft) 15.5 50 0.0450
Velocity (ft/sec) 0.05
13.2
299
0.0229
0.38
3.6
168
0.0954
0.77
5.8
165
0.0364
0.48
38.1
682
Total
Capacity (cfs)
Printed 4/24/2017 Page 12
Description Sheet Flow, Sheet Flow Woods: Dense underbrush n= 0.800 P2= 3.23" Shallow Concentrated Flow, Shallow Concentrated Flow 1 Forest w/Heavy Litter Kv= 2.5 fps Shallow Concentrated Flow, Shallow Concentrated Flow 2 Forest w/Heavy Litter Kv= 2.5 fps Shallow Concentrated Flow, Shallow Concentrated Flow 3 Forest w/Heavy Litter Kv= 2.5 fps
Summary for Subcatchment 3S: E-DA-3 Runoff
=
5.29 cfs @ 12.56 hrs, Volume=
0.841 af, Depth> 1.23"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 25-YR NRCC Rainfall=6.05" Area (ac) 0.077 0.244 0.013 0.071 2.320 4.202 0.198 0.081 0.994 0.021 8.221 7.816 0.405 0.071
CN 98 98 98 98 30 55 77 39 61 80 51
Description Paved parking, HSG A Paved parking, HSG B Paved parking, HSG D Unconnected roofs, HSG B Woods, Good, HSG A Woods, Good, HSG B Woods, Good, HSG D >75% Grass cover, Good, HSG A >75% Grass cover, Good, HSG B >75% Grass cover, Good, HSG D Weighted Average 95.07% Pervious Area 4.93% Impervious Area 17.53% Unconnected
Tc Length Slope (min) (feet) (ft/ft) 14.8 50 0.0500
Velocity (ft/sec) 0.06
12.1
347
0.0363
0.48
7.0
301
0.0830
0.72
33.9
698
Total
Capacity (cfs)
Description Sheet Flow, Sheet Flow Woods: Dense underbrush n= 0.800 P2= 3.23" Shallow Concentrated Flow, Shallow Concentrated Flow 1 Forest w/Heavy Litter Kv= 2.5 fps Shallow Concentrated Flow, Shallow Concentrated Flow 2 Forest w/Heavy Litter Kv= 2.5 fps
2836.00 Pre-Development
Type III 24-hr 25-YR NRCC Rainfall=6.05"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Printed 4/24/2017 Page 13
Summary for Reach 10R: E-DP-1 [40] Hint: Not Described (Outflow=Inflow) Inflow Area = Inflow = Outflow =
8.952 ac, 0.00% Impervious, Inflow Depth > 0.21" for 25-YR NRCC event 0.27 cfs @ 13.97 hrs, Volume= 0.159 af 0.27 cfs @ 13.97 hrs, Volume= 0.159 af, Atten= 0%, Lag= 0.0 min
Routing by Stor-Ind+Trans method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs
Summary for Reach 20R: E-DP-2 [40] Hint: Not Described (Outflow=Inflow) Inflow Area = Inflow = Outflow =
6.399 ac, 3.34% Impervious, Inflow Depth > 1.30" for 25-YR NRCC event 4.21 cfs @ 12.62 hrs, Volume= 0.693 af 4.21 cfs @ 12.62 hrs, Volume= 0.693 af, Atten= 0%, Lag= 0.0 min
Routing by Stor-Ind+Trans method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs
Summary for Reach 30R: E-DP-3 [40] Hint: Not Described (Outflow=Inflow) Inflow Area = Inflow = Outflow =
8.221 ac, 4.93% Impervious, Inflow Depth > 1.23" for 25-YR NRCC event 5.29 cfs @ 12.56 hrs, Volume= 0.841 af 5.29 cfs @ 12.56 hrs, Volume= 0.841 af, Atten= 0%, Lag= 0.0 min
Routing by Stor-Ind+Trans method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs
2836.00 Pre-Development
Type III 24-hr 100-YR NRCC Rainfall=8.59"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Printed 4/24/2017 Page 14
Summary for Subcatchment 1S: E-DA-1 Runoff
=
3.08 cfs @ 12.64 hrs, Volume=
0.676 af, Depth> 0.91"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 100-YR NRCC Rainfall=8.59" Area (ac) 7.407 1.544 0.001 8.952 8.952
CN 30 55 77 34
Description Woods, Good, HSG A Woods, Good, HSG B Woods, Good, HSG D Weighted Average 100.00% Pervious Area
Tc Length Slope (min) (feet) (ft/ft) 13.0 50 0.0690
Velocity (ft/sec) 0.06
11.9
272
0.0231
0.38
6.4
308
0.1045
0.81
31.3
630
Total
Capacity (cfs)
Description Sheet Flow, Sheet Flow Woods: Dense underbrush n= 0.800 P2= 3.23" Shallow Concentrated Flow, Shallow Concentrated Flow 1 Forest w/Heavy Litter Kv= 2.5 fps Shallow Concentrated Flow, Shallow Concentrated Flow 2 Forest w/Heavy Litter Kv= 2.5 fps
Summary for Subcatchment 2S: E-DA-2 Runoff
=
10.21 cfs @ 12.57 hrs, Volume=
1.503 af, Depth> 2.82"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 100-YR NRCC Rainfall=8.59" Area (ac) 0.105 0.053 0.056 1.417 3.482 0.057 1.229 6.399 6.185 0.214 0.056
CN 98 98 98 30 55 77 61 52
Description Paved parking, HSG B Paved parking, HSG D Unconnected roofs, HSG B Woods, Good, HSG A Woods, Good, HSG B Woods, Good, HSG D >75% Grass cover, Good, HSG B Weighted Average 96.66% Pervious Area 3.34% Impervious Area 26.17% Unconnected
2836.00 Pre-Development
Type III 24-hr 100-YR NRCC Rainfall=8.59"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Tc Length Slope (min) (feet) (ft/ft) 15.5 50 0.0450
Velocity (ft/sec) 0.05
13.2
299
0.0229
0.38
3.6
168
0.0954
0.77
5.8
165
0.0364
0.48
38.1
682
Total
Capacity (cfs)
Printed 4/24/2017 Page 15
Description Sheet Flow, Sheet Flow Woods: Dense underbrush n= 0.800 P2= 3.23" Shallow Concentrated Flow, Shallow Concentrated Flow 1 Forest w/Heavy Litter Kv= 2.5 fps Shallow Concentrated Flow, Shallow Concentrated Flow 2 Forest w/Heavy Litter Kv= 2.5 fps Shallow Concentrated Flow, Shallow Concentrated Flow 3 Forest w/Heavy Litter Kv= 2.5 fps
Summary for Subcatchment 3S: E-DA-3 Runoff
=
13.23 cfs @ 12.52 hrs, Volume=
1.855 af, Depth> 2.71"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 100-YR NRCC Rainfall=8.59" Area (ac) 0.077 0.244 0.013 0.071 2.320 4.202 0.198 0.081 0.994 0.021 8.221 7.816 0.405 0.071
CN 98 98 98 98 30 55 77 39 61 80 51
Description Paved parking, HSG A Paved parking, HSG B Paved parking, HSG D Unconnected roofs, HSG B Woods, Good, HSG A Woods, Good, HSG B Woods, Good, HSG D >75% Grass cover, Good, HSG A >75% Grass cover, Good, HSG B >75% Grass cover, Good, HSG D Weighted Average 95.07% Pervious Area 4.93% Impervious Area 17.53% Unconnected
Tc Length Slope (min) (feet) (ft/ft) 14.8 50 0.0500
Velocity (ft/sec) 0.06
12.1
347
0.0363
0.48
7.0
301
0.0830
0.72
33.9
698
Total
Capacity (cfs)
Description Sheet Flow, Sheet Flow Woods: Dense underbrush n= 0.800 P2= 3.23" Shallow Concentrated Flow, Shallow Concentrated Flow 1 Forest w/Heavy Litter Kv= 2.5 fps Shallow Concentrated Flow, Shallow Concentrated Flow 2 Forest w/Heavy Litter Kv= 2.5 fps
2836.00 Pre-Development
Type III 24-hr 100-YR NRCC Rainfall=8.59"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Printed 4/24/2017 Page 16
Summary for Reach 10R: E-DP-1 [40] Hint: Not Described (Outflow=Inflow) Inflow Area = Inflow = Outflow =
8.952 ac, 0.00% Impervious, Inflow Depth > 0.91" for 100-YR NRCC event 3.08 cfs @ 12.64 hrs, Volume= 0.676 af 3.08 cfs @ 12.64 hrs, Volume= 0.676 af, Atten= 0%, Lag= 0.0 min
Routing by Stor-Ind+Trans method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs
Summary for Reach 20R: E-DP-2 [40] Hint: Not Described (Outflow=Inflow) Inflow Area = Inflow = Outflow =
6.399 ac, 3.34% Impervious, Inflow Depth > 2.82" for 100-YR NRCC event 10.21 cfs @ 12.57 hrs, Volume= 1.503 af 10.21 cfs @ 12.57 hrs, Volume= 1.503 af, Atten= 0%, Lag= 0.0 min
Routing by Stor-Ind+Trans method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs
Summary for Reach 30R: E-DP-3 [40] Hint: Not Described (Outflow=Inflow) Inflow Area = Inflow = Outflow =
8.221 ac, 4.93% Impervious, Inflow Depth > 2.71" for 100-YR NRCC event 13.23 cfs @ 12.52 hrs, Volume= 1.855 af 13.23 cfs @ 12.52 hrs, Volume= 1.855 af, Atten= 0%, Lag= 0.0 min
Routing by Stor-Ind+Trans method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs
Appendix C Post-Development Hydrologic Analysis
Extreme Precipitation Tables: 42.201°N, 71.531°W
Page 1 of 1
Extreme Precipitation Tables Northeast Regional Climate Center Data represents point estimates calculated from partial duration series. All precipitation amounts are displayed in inches. Smoothing State Location Longitude Latitude Elevation Date/Time
Yes Massachusetts 71.531 degrees West 42.201 degrees North 0 feet Thu, 23 Mar 2017 17:26:16 -0400
Extreme Precipitation Estimates 1yr 2yr 5yr 10yr 25yr 50yr 100yr 200yr 500yr
5min 0.29 0.35 0.42 0.47 0.56 0.63 0.72 0.82 0.99
10min 0.44 0.54 0.65 0.74 0.89 1.01 1.17 1.34 1.63
15min 0.54 0.67 0.81 0.93 1.13 1.29 1.51 1.74 2.13
30min 0.71 0.89 1.09 1.27 1.55 1.81 2.13 2.49 3.09
60min 120min 1hr 2hr 3hr 6hr 12hr 24hr 48hr 0.89 1.13 1yr 0.77 1.07 1.31 1.65 2.10 2.68 2.92 1yr 1.11 1.40 2yr 0.96 1.29 1.63 2.04 2.57 3.23 3.52 2yr 1.39 1.77 5yr 1.20 1.61 2.06 2.59 3.24 4.06 4.48 5yr 1.65 2.11 10yr 1.42 1.90 2.46 3.10 3.88 4.84 5.38 10yr 2.06 2.66 25yr 1.78 2.36 3.11 3.93 4.91 6.09 6.87 25yr 2.44 3.19 50yr 2.11 2.79 3.74 4.72 5.88 7.26 8.26 50yr 2.90 3.80 100yr 2.50 3.30 4.47 5.64 7.02 8.66 9.95 100yr 3.44 4.54 200yr 2.97 3.90 5.35 6.76 8.40 10.32 11.98 200yr 4.32 5.75 500yr 3.73 4.87 6.79 8.58 10.65 13.04 15.32 500yr
1day 2.37 2.86 3.59 4.28 5.39 6.42 7.66 9.14 11.54
2day 2.81 3.38 4.31 5.18 6.60 7.95 9.56 11.52 14.73
4day 3.25 3.89 4.93 5.91 7.50 8.99 10.79 12.94 16.47
7day 3.92 4.62 5.83 6.95 8.78 10.47 12.50 14.93 18.89
10day 4.56 5.25 6.52 7.68 9.54 11.26 13.28 15.67 19.51
1yr 2yr 5yr 10yr 25yr 50yr 100yr 200yr 500yr
Lower Confidence Limits 1yr 2yr 5yr 10yr 25yr 50yr 100yr 200yr 500yr
5min 0.23 0.34 0.38 0.42 0.49 0.54 0.59 0.66 0.75
10min 0.35 0.53 0.59 0.65 0.74 0.82 0.90 0.99 1.12
15min 0.43 0.65 0.73 0.81 0.92 1.02 1.13 1.25 1.44
30min 0.58 0.88 1.00 1.13 1.31 1.46 1.63 1.81 2.09
60min 120min 1hr 2hr 3hr 6hr 12hr 24hr 48hr 0.71 0.94 1yr 0.61 0.92 1.07 1.42 1.85 2.35 2.70 1yr 1.08 1.27 2yr 0.93 1.24 1.45 1.91 2.44 3.13 3.40 2yr 1.28 1.52 5yr 1.10 1.48 1.72 2.25 2.86 3.73 4.12 5yr 1.45 1.73 10yr 1.26 1.69 1.95 2.55 3.22 4.27 4.76 10yr 1.73 2.05 25yr 1.49 2.01 2.31 3.02 3.78 5.11 5.72 25yr 1.97 2.33 50yr 1.70 2.28 2.62 3.42 4.26 5.85 6.59 50yr 2.23 2.65 100yr 1.93 2.59 2.97 3.88 4.81 6.71 7.57 100yr 2.53 3.02 200yr 2.18 2.96 3.38 4.42 5.44 7.70 8.68 200yr 2.97 3.60 500yr 2.56 3.52 3.99 5.25 6.42 9.26 10.39 500yr
1day 2.08 2.77 3.31 3.78 4.53 5.18 5.94 6.81 8.19
2day 2.60 3.27 3.97 4.57 5.50 6.34 7.28 8.35 9.99
4day 2.95 3.76 4.54 5.24 6.34 7.33 8.48 9.80 11.90
7day 3.58 4.46 5.36 6.14 7.36 8.43 9.70 11.14 13.38
10day 4.11 5.08 6.02 6.84 8.07 9.18 10.44 11.89 14.14
1yr 2yr 5yr 10yr 25yr 50yr 100yr 200yr 500yr
Upper Confidence Limits 1yr 2yr 5yr 10yr 25yr 50yr 100yr 200yr 500yr
5min 0.32 0.37 0.45 0.54 0.69 0.82 0.99 1.19 1.55
10min 0.49 0.56 0.70 0.83 1.04 1.25 1.50 1.80 2.30
15min 0.60 0.69 0.87 1.03 1.30 1.56 1.88 2.28 2.96
30min 0.81 0.94 1.19 1.44 1.86 2.24 2.71 3.30 4.30
60min 120min 1hr 2hr 3hr 6hr 12hr 24hr 48hr 1.00 1.19 1yr 0.86 1.17 1.37 1.76 2.30 2.93 3.16 1yr 1.16 1.36 2yr 1.00 1.33 1.57 2.04 2.60 3.36 3.66 2yr 1.51 1.78 5yr 1.31 1.74 2.04 2.62 3.31 4.39 4.86 5yr 1.86 2.19 10yr 1.60 2.14 2.50 3.18 3.96 5.39 6.06 10yr 2.44 2.88 25yr 2.11 2.82 3.27 4.08 5.05 7.07 8.12 25yr 3.01 3.54 50yr 2.60 3.46 4.02 4.94 6.06 8.69 10.12 50yr 3.72 4.36 100yr 3.21 4.26 4.93 5.98 7.28 10.67 12.66 100yr 4.60 5.37 200yr 3.97 5.25 6.07 7.24 8.73 13.10 15.85 200yr 6.11 7.08 500yr 5.28 6.92 7.98 9.32 11.12 17.21 21.36 500yr
1day 2.60 2.97 3.89 4.77 6.26 7.69 9.44 11.59 15.23
2day 3.04 3.52 4.67 5.83 7.80 9.73 12.18 15.24 20.54
4day 3.53 4.05 5.37 6.65 8.85 10.98 13.64 16.93 22.55
7day 4.23 4.80 6.35 7.84 10.39 12.84 15.88 19.65 26.05
10day 4.89 5.44 7.04 8.58 11.15 13.62 16.61 20.23 26.30
1yr 2yr 5yr 10yr 25yr 50yr 100yr 200yr 500yr
Powered by ACIS
file:///G:/Projdata/2836/Transfers/In/NRCC/2017-03-23/output.htm
4/24/2017
101AS P-DA-1A
101BS
101AP
110R
P-DA-1B
BASIN-1
P-DP-1
103AS
102AS
P-DA-3A
P-DA-2A
130R
103P
103BS
102BS
102P
120R
P-DP-3
BASIN-3
P-DA-3B
P-DA-2B
BASIN-2
P-DP-2
POST-DEVELOPMENT
Subcat
Reach
Pond
Link
Routing Diagram for 283600HC001A Prepared by Microsoft, Printed 4/26/2017 HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
2836.00 Post-Development
283600HC001A Prepared by Microsoft HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Area Listing (selected nodes) Area (acres)
CN
0.074 2.231 0.021 0.300 7.166 3.970 0.078 0.252 0.013 0.113 0.129 0.053 3.974 4.892 0.316 23.582
39 61 80 96 30 58 98 98 98 98 98 98 30 55 77 46
Description (subcatchment-numbers) >75% Grass cover, Good, HSG A (103AS, 103BS) >75% Grass cover, Good, HSG B (102AS, 103AS, 103BS) >75% Grass cover, Good, HSG D (103AS) Gravel surface, HSG B (101BS, 102BS, 103BS) Meadow, non-grazed, HSG A (101AS, 101BS, 103AS, 103BS) Meadow, non-grazed, HSG B (101BS, 102AS, 102BS, 103BS) Paved parking, HSG A (103AS, 103BS) Paved parking, HSG B (103BS) Paved parking, HSG D (103AS) Unconnected pavement, HSG B (101BS, 102AS) Unconnected roofs, HSG B (102AS, 103BS) Water Surface, HSG B (102AS) Woods, Good, HSG A (101AS, 101BS, 102AS, 103AS, 103BS) Woods, Good, HSG B (101BS, 102AS, 102BS, 103AS, 103BS) Woods, Good, HSG D (101AS, 102AS, 103AS) TOTAL AREA
Printed 4/26/2017 Page 2
2836.00 Post-Development
283600HC001A Prepared by Microsoft HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Soil Listing (selected nodes) Area (acres)
Soil Group
Subcatchment Numbers
11.292 11.940 0.000 0.350 0.000 23.582
HSG A HSG B HSG C HSG D Other
101AS, 101BS, 102AS, 103AS, 103BS 101BS, 102AS, 102BS, 103AS, 103BS 101AS, 102AS, 103AS TOTAL AREA
Printed 4/26/2017 Page 3
2836.00 Post-Development
283600HC001A Printed 4/26/2017 Page 4
Prepared by Microsoft HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Ground Covers (selected nodes) HSG-A (acres)
HSG-B (acres)
HSG-C (acres)
HSG-D (acres)
Other (acres)
Total (acres)
0.074
2.231
0.000
0.021
0.000
2.326
0.000
0.300
0.000
0.000
0.000
0.300
7.166
3.970
0.000
0.000
0.000
11.136
0.078
0.252
0.000
0.013
0.000
0.343
0.000
0.113
0.000
0.000
0.000
0.113
0.000
0.129
0.000
0.000
0.000
0.129
0.000 3.974
0.053 4.892
0.000 0.000
0.000 0.316
0.000 0.000
0.053 9.182
11.292
11.940
0.000
0.350
0.000
23.582
Ground Cover
Subcatchment Numbers
>75% Grass cover, Good 102AS, 103AS, 103BS Gravel surface 101BS, 102BS, 103BS Meadow, non-grazed 101AS, 101BS, 102AS, 102BS, 103AS, 103BS Paved parking 103AS, 103BS Unconnected pavement 101BS, 102AS Unconnected roofs 102AS, 103BS Water Surface 102AS Woods, Good 101AS, 101BS, 102AS, 102BS, 103AS, 103BS TOTAL AREA
2836.00 Post-Development
Type III 24-hr 2-YR NRCC Rainfall=3.22"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Printed 4/26/2017 Page 5
Summary for Subcatchment 101AS: P-DA-1A [45] Hint: Runoff=Zero Runoff
=
0.00 cfs @
0.00 hrs, Volume=
0.000 af, Depth= 0.00"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 2-YR NRCC Rainfall=3.22" Area (ac) 1.479 0.001 0.403 1.883 1.883
CN 30 77 30 30
Tc Length (min) (feet) 6.0
Description Woods, Good, HSG A Woods, Good, HSG D Meadow, non-grazed, HSG A Weighted Average 100.00% Pervious Area Slope (ft/ft)
Velocity (ft/sec)
Capacity (cfs)
Description Direct Entry, Minimum
Summary for Subcatchment 101BS: P-DA-1B [45] Hint: Runoff=Zero Runoff
=
0.00 cfs @
0.00 hrs, Volume=
0.000 af, Depth= 0.00"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 2-YR NRCC Rainfall=3.22" Area (ac) 0.452 2.021 5.336 0.363 0.008 0.051 8.231 8.223 0.008 0.008
CN 30 55 30 58 98 96 38
Description Woods, Good, HSG A Woods, Good, HSG B Meadow, non-grazed, HSG A Meadow, non-grazed, HSG B Unconnected pavement, HSG B Gravel surface, HSG B Weighted Average 99.90% Pervious Area 0.10% Impervious Area 100.00% Unconnected
Tc Length Slope (min) (feet) (ft/ft) 13.0 50 0.0690
Velocity (ft/sec) 0.06
12.8
292
0.0231
0.38
5.4
260
0.1045
0.81
31.2
602
Total
Capacity (cfs)
Description Sheet Flow, Sheet Flow Woods: Dense underbrush n= 0.800 P2= 3.23" Shallow Concentrated Flow, Shallow Concentrated Flow 1 Forest w/Heavy Litter Kv= 2.5 fps Shallow Concentrated Flow, Shallow Concentrated Flow 2 Forest w/Heavy Litter Kv= 2.5 fps
2836.00 Post-Development
Type III 24-hr 2-YR NRCC Rainfall=3.22"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Printed 4/26/2017 Page 6
Summary for Subcatchment 102AS: P-DA-2A Runoff
=
0.19 cfs @ 12.49 hrs, Volume=
0.057 af, Depth> 0.18"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 2-YR NRCC Rainfall=3.22" Area (ac) 0.105 0.053 0.057 1.156 0.773 0.117 1.205 0.432 3.898 3.683 0.215 0.162
CN 98 98 98 30 55 77 61 58 53
Adj
52
Tc Length Slope (min) (feet) (ft/ft) 3.8 50 0.0514
Description Unconnected pavement, HSG B Water Surface, HSG B Unconnected roofs, HSG B Woods, Good, HSG A Woods, Good, HSG B Woods, Good, HSG D >75% Grass cover, Good, HSG B Meadow, non-grazed, HSG B Weighted Average, UI Adjusted 94.48% Pervious Area 5.52% Impervious Area 75.35% Unconnected Velocity (ft/sec) 0.22
4.3
208
0.0133
0.81
1.3
168
0.0954
2.16
2.2
121
0.0165
0.90
11.6
547
Total
Capacity (cfs)
Description Sheet Flow, Sheet Flow Grass: Short n= 0.150 P2= 3.23" Shallow Concentrated Flow, Shallow Concentrated Flow 1 Short Grass Pasture Kv= 7.0 fps Shallow Concentrated Flow, Shallow Concentrated Flow 2 Short Grass Pasture Kv= 7.0 fps Shallow Concentrated Flow, Shallow Concentrated Flow 3 Short Grass Pasture Kv= 7.0 fps
Summary for Subcatchment 102BS: P-DA-2B Runoff
=
0.39 cfs @ 12.20 hrs, Volume=
0.051 af, Depth> 0.45"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 2-YR NRCC Rainfall=3.22" Area (ac) 0.106 1.138 0.106 1.350 1.350
CN 55 58 96 61
Description Woods, Good, HSG B Meadow, non-grazed, HSG B Gravel surface, HSG B Weighted Average 100.00% Pervious Area
2836.00 Post-Development
Type III 24-hr 2-YR NRCC Rainfall=3.22"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Tc Length Slope (min) (feet) (ft/ft) 6.4 50 0.0144 3.4
172
0.1 9.9
Velocity (ft/sec) 0.13
0.0144
0.84
15 0.2000
3.13
237
Capacity (cfs)
Printed 4/26/2017 Page 7
Description Sheet Flow, Sheet Flow Grass: Short n= 0.150 P2= 3.23" Shallow Concentrated Flow, Shallow Concentrated Flow 1 Short Grass Pasture Kv= 7.0 fps Shallow Concentrated Flow, Shallow Concentrated Flow 2 Short Grass Pasture Kv= 7.0 fps
Total
Summary for Subcatchment 103AS: P-DA-3A Runoff
=
0.00 cfs @ 21.38 hrs, Volume=
0.002 af, Depth> 0.01"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 2-YR NRCC Rainfall=3.22" Area (ac) 0.022 0.013 0.670 0.068 0.198 0.020 0.044 0.021 0.236 1.292 1.257 0.035
CN 98 98 30 55 77 39 61 80 30 42
Tc Length (min) (feet) 6.0
Description Paved parking, HSG A Paved parking, HSG D Woods, Good, HSG A Woods, Good, HSG B Woods, Good, HSG D >75% Grass cover, Good, HSG A >75% Grass cover, Good, HSG B >75% Grass cover, Good, HSG D Meadow, non-grazed, HSG A Weighted Average 97.29% Pervious Area 2.71% Impervious Area Slope (ft/ft)
Velocity (ft/sec)
Capacity (cfs)
Description Direct Entry, Minimum
Summary for Subcatchment 103BS: P-DA-3B Runoff
=
0.54 cfs @ 12.51 hrs, Volume=
0.131 af, Depth> 0.23"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 2-YR NRCC Rainfall=3.22"
2836.00 Post-Development
Type III 24-hr 2-YR NRCC Rainfall=3.22"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Area (ac) 0.056 0.252 0.072 0.217 1.924 0.054 0.982 1.191 2.037 0.143 6.928 6.548 0.380 0.072
CN 98 98 98 30 55 39 61 30 58 96 55
Adj
54
Tc Length Slope (min) (feet) (ft/ft) 9.8 50 0.0050
Description Paved parking, HSG A Paved parking, HSG B Unconnected roofs, HSG B Woods, Good, HSG A Woods, Good, HSG B >75% Grass cover, Good, HSG A >75% Grass cover, Good, HSG B Meadow, non-grazed, HSG A Meadow, non-grazed, HSG B Gravel surface, HSG B Weighted Average, UI Adjusted 94.52% Pervious Area 5.48% Impervious Area 18.95% Unconnected Velocity (ft/sec) 0.09
4.3
347
0.0363
1.33
1.8
192
0.0625
1.75
31 0.0955
2.16
0.2 16.1
620
Printed 4/26/2017 Page 8
Capacity (cfs)
Description Sheet Flow, Sheet Flow Grass: Short n= 0.150 P2= 3.23" Shallow Concentrated Flow, Shallow Concentrated Flow 1 Short Grass Pasture Kv= 7.0 fps Shallow Concentrated Flow, Shallow Concentrated Flow 2 Short Grass Pasture Kv= 7.0 fps Shallow Concentrated Flow, Shallow Concentrated Flow 3 Short Grass Pasture Kv= 7.0 fps
Total
Summary for Reach 110R: P-DP-1 [40] Hint: Not Described (Outflow=Inflow) Inflow Area = Inflow = Outflow =
10.114 ac, 0.08% Impervious, Inflow Depth = 0.00" for 2-YR NRCC event 0.00 cfs @ 0.00 hrs, Volume= 0.000 af 0.00 cfs @ 0.00 hrs, Volume= 0.000 af, Atten= 0%, Lag= 0.0 min
Routing by Stor-Ind+Trans method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs
Summary for Reach 120R: P-DP-2 [40] Hint: Not Described (Outflow=Inflow) Inflow Area = Inflow = Outflow =
5.248 ac, 4.10% Impervious, Inflow Depth > 0.13" for 2-YR NRCC event 0.19 cfs @ 12.49 hrs, Volume= 0.057 af 0.19 cfs @ 12.49 hrs, Volume= 0.057 af, Atten= 0%, Lag= 0.0 min
Routing by Stor-Ind+Trans method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs
2836.00 Post-Development
Type III 24-hr 2-YR NRCC Rainfall=3.22"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Printed 4/26/2017 Page 9
Summary for Reach 130R: P-DP-3 [40] Hint: Not Described (Outflow=Inflow) Inflow Area = Inflow = Outflow =
8.220 ac, 5.05% Impervious, Inflow Depth > 0.11" for 2-YR NRCC event 0.14 cfs @ 16.22 hrs, Volume= 0.072 af 0.14 cfs @ 16.22 hrs, Volume= 0.072 af, Atten= 0%, Lag= 0.0 min
Routing by Stor-Ind+Trans method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs
Summary for Pond 101AP: BASIN-1 Inflow Area = Inflow = Outflow = Primary =
8.231 ac, 0.10% Impervious, Inflow Depth = 0.00" for 2-YR NRCC event 0.00 cfs @ 0.00 hrs, Volume= 0.000 af 0.00 cfs @ 0.00 hrs, Volume= 0.000 af, Atten= 0%, Lag= 0.0 min 0.00 cfs @ 0.00 hrs, Volume= 0.000 af
Routing by Stor-Ind method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Peak Elev= 493.00' @ 0.00 hrs Surf.Area= 3,844 sf Storage= 0 cf Plug-Flow detention time= (not calculated: initial storage exceeds outflow) Center-of-Mass det. time= (not calculated: no inflow) Volume #1
Invert 493.00'
Elevation (feet) 493.00 494.00 496.00 Device #1
Avail.Storage 30,824 cf
Surf.Area (sq-ft) 3,844 8,790 15,717
Routing Primary
Invert 495.00'
#2
Primary
494.00'
#3
Primary
493.75'
Storage Description Custom Stage Data (Prismatic)Listed below (Recalc)
Inc.Store (cubic-feet) 0 6,317 24,507
Cum.Store (cubic-feet) 0 6,317 30,824
Outlet Devices 20.0' long x 10.0' breadth Broad-Crested Rectangular Weir Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 Coef. (English) 2.49 2.56 2.70 2.69 2.68 2.69 2.67 2.64 12.0" Round Culvert L= 30.0' CPP, mitered to conform to fill, Ke= 0.700 Inlet / Outlet Invert= 494.00' / 493.00' S= 0.0333 '/' Cc= 0.900 n= 0.013 Corrugated PE, smooth interior, Flow Area= 0.79 sf 12.0" Round Culvert L= 30.0' CPP, mitered to conform to fill, Ke= 0.700 Inlet / Outlet Invert= 493.75' / 493.00' S= 0.0250 '/' Cc= 0.900 n= 0.013 Corrugated PE, smooth interior, Flow Area= 0.79 sf
Primary OutFlow Max=0.00 cfs @ 0.00 hrs HW=493.00' (Free Discharge) 1=Broad-Crested Rectangular Weir ( Controls 0.00 cfs) 2=Culvert ( Controls 0.00 cfs) 3=Culvert ( Controls 0.00 cfs)
2836.00 Post-Development
Type III 24-hr 2-YR NRCC Rainfall=3.22"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Printed 4/26/2017 Page 10
Summary for Pond 102P: BASIN-2 Inflow Area = Inflow = Outflow = Primary =
1.350 ac, 0.00% Impervious, Inflow Depth > 0.45" for 2-YR NRCC event 0.39 cfs @ 12.20 hrs, Volume= 0.051 af 0.00 cfs @ 0.00 hrs, Volume= 0.000 af, Atten= 100%, Lag= 0.0 min 0.00 cfs @ 0.00 hrs, Volume= 0.000 af
Routing by Stor-Ind method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Peak Elev= 526.21' @ 24.00 hrs Surf.Area= 11,073 sf Storage= 2,207 cf Plug-Flow detention time= (not calculated: initial storage exceeds outflow) Center-of-Mass det. time= (not calculated: no outflow) Volume #1
Invert 526.00'
Elevation (feet) 526.00 528.00 Device #1 #2
Avail.Storage 28,174 cf
Surf.Area (sq-ft) 10,288 17,886
Storage Description Basin (Prismatic) Listed below (Recalc)
Inc.Store (cubic-feet) 0 28,174
Routing Primary
Invert 527.00'
Primary
526.25'
Cum.Store (cubic-feet) 0 28,174
Outlet Devices 20.0' long x 10.0' breadth Riprap Overflow Weir Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 Coef. (English) 2.49 2.56 2.70 2.69 2.68 2.69 2.67 2.64 6.0" Round Culvert L= 60.0' CPP, mitered to conform to fill, Ke= 0.700 Inlet / Outlet Invert= 526.25' / 525.00' S= 0.0208 '/' Cc= 0.900 n= 0.013 Corrugated PE, smooth interior, Flow Area= 0.20 sf
Primary OutFlow Max=0.00 cfs @ 0.00 hrs HW=526.00' (Free Discharge) 1=Riprap Overflow Weir ( Controls 0.00 cfs) 2=Culvert ( Controls 0.00 cfs)
Summary for Pond 103P: BASIN-3 Inflow Area = Inflow = Outflow = Primary =
6.928 ac, 0.54 cfs @ 0.13 cfs @ 0.13 cfs @
5.48% Impervious, Inflow Depth > 0.23" for 2-YR NRCC event 12.51 hrs, Volume= 0.131 af 16.20 hrs, Volume= 0.070 af, Atten= 75%, Lag= 221.5 min 16.20 hrs, Volume= 0.070 af
Routing by Stor-Ind method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Peak Elev= 501.52' @ 16.20 hrs Surf.Area= 6,278 sf Storage= 2,867 cf Plug-Flow detention time= 315.9 min calculated for 0.070 af (54% of inflow) Center-of-Mass det. time= 163.4 min ( 1,131.9 - 968.6 )
2836.00 Post-Development
Type III 24-hr 2-YR NRCC Rainfall=3.22"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Volume #1
Invert 501.00'
Elevation (feet) 501.00 502.00 504.00 Device #1
Avail.Storage 28,347 cf
Surf.Area (sq-ft) 4,660 7,748 14,395
Routing Primary
Invert 503.00'
#2
Primary
501.42'
#3
Primary
501.42'
Printed 4/26/2017 Page 11
Storage Description Custom Stage Data (Prismatic)Listed below (Recalc)
Inc.Store (cubic-feet) 0 6,204 22,143
Cum.Store (cubic-feet) 0 6,204 28,347
Outlet Devices 20.0' long x 10.0' breadth Broad-Crested Rectangular Weir Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 Coef. (English) 2.49 2.56 2.70 2.69 2.68 2.69 2.67 2.64 12.0" Round Culvert X 2.00 L= 35.0' CPP, mitered to conform to fill, Ke= 0.700 Inlet / Outlet Invert= 501.42' / 500.00' S= 0.0406 '/' Cc= 0.900 n= 0.013 Corrugated PE, smooth interior, Flow Area= 0.79 sf 15.0" Round Culvert L= 35.0' CPP, mitered to conform to fill, Ke= 0.700 Inlet / Outlet Invert= 501.42' / 500.00' S= 0.0406 '/' Cc= 0.900 n= 0.013 Corrugated PE, smooth interior, Flow Area= 1.23 sf
Primary OutFlow Max=0.13 cfs @ 16.20 hrs HW=501.52' (Free Discharge) 1=Broad-Crested Rectangular Weir ( Controls 0.00 cfs) 2=Culvert (Inlet Controls 0.08 cfs @ 0.97 fps) 3=Culvert (Inlet Controls 0.05 cfs @ 0.97 fps)
2836.00 Post-Development
Type III 24-hr 10-YR NRCC Rainfall=4.81"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Printed 4/26/2017 Page 12
Summary for Subcatchment 101AS: P-DA-1A [73] Warning: Peak may fall outside time span Runoff
=
0.00 cfs @ 24.00 hrs, Volume=
0.000 af, Depth> 0.00"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 10-YR NRCC Rainfall=4.81" Area (ac) 1.479 0.001 0.403 1.883 1.883
CN 30 77 30 30
Tc Length (min) (feet) 6.0
Description Woods, Good, HSG A Woods, Good, HSG D Meadow, non-grazed, HSG A Weighted Average 100.00% Pervious Area Slope (ft/ft)
Velocity (ft/sec)
Capacity (cfs)
Description Direct Entry, Minimum
Summary for Subcatchment 101BS: P-DA-1B Runoff
=
0.15 cfs @ 14.94 hrs, Volume=
0.090 af, Depth> 0.13"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 10-YR NRCC Rainfall=4.81" Area (ac) 0.452 2.021 5.336 0.363 0.008 0.051 8.231 8.223 0.008 0.008
CN 30 55 30 58 98 96 38
Description Woods, Good, HSG A Woods, Good, HSG B Meadow, non-grazed, HSG A Meadow, non-grazed, HSG B Unconnected pavement, HSG B Gravel surface, HSG B Weighted Average 99.90% Pervious Area 0.10% Impervious Area 100.00% Unconnected
Tc Length Slope (min) (feet) (ft/ft) 13.0 50 0.0690
Velocity (ft/sec) 0.06
12.8
292
0.0231
0.38
5.4
260
0.1045
0.81
31.2
602
Total
Capacity (cfs)
Description Sheet Flow, Sheet Flow Woods: Dense underbrush n= 0.800 P2= 3.23" Shallow Concentrated Flow, Shallow Concentrated Flow 1 Forest w/Heavy Litter Kv= 2.5 fps Shallow Concentrated Flow, Shallow Concentrated Flow 2 Forest w/Heavy Litter Kv= 2.5 fps
2836.00 Post-Development
Type III 24-hr 10-YR NRCC Rainfall=4.81"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Printed 4/26/2017 Page 13
Summary for Subcatchment 102AS: P-DA-2A Runoff
=
1.81 cfs @ 12.22 hrs, Volume=
0.233 af, Depth> 0.72"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 10-YR NRCC Rainfall=4.81" Area (ac) 0.105 0.053 0.057 1.156 0.773 0.117 1.205 0.432 3.898 3.683 0.215 0.162
CN 98 98 98 30 55 77 61 58 53
Adj
52
Tc Length Slope (min) (feet) (ft/ft) 3.8 50 0.0514
Description Unconnected pavement, HSG B Water Surface, HSG B Unconnected roofs, HSG B Woods, Good, HSG A Woods, Good, HSG B Woods, Good, HSG D >75% Grass cover, Good, HSG B Meadow, non-grazed, HSG B Weighted Average, UI Adjusted 94.48% Pervious Area 5.52% Impervious Area 75.35% Unconnected Velocity (ft/sec) 0.22
4.3
208
0.0133
0.81
1.3
168
0.0954
2.16
2.2
121
0.0165
0.90
11.6
547
Total
Capacity (cfs)
Description Sheet Flow, Sheet Flow Grass: Short n= 0.150 P2= 3.23" Shallow Concentrated Flow, Shallow Concentrated Flow 1 Short Grass Pasture Kv= 7.0 fps Shallow Concentrated Flow, Shallow Concentrated Flow 2 Short Grass Pasture Kv= 7.0 fps Shallow Concentrated Flow, Shallow Concentrated Flow 3 Short Grass Pasture Kv= 7.0 fps
Summary for Subcatchment 102BS: P-DA-2B Runoff
=
1.54 cfs @ 12.16 hrs, Volume=
0.141 af, Depth> 1.25"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 10-YR NRCC Rainfall=4.81" Area (ac) 0.106 1.138 0.106 1.350 1.350
CN 55 58 96 61
Description Woods, Good, HSG B Meadow, non-grazed, HSG B Gravel surface, HSG B Weighted Average 100.00% Pervious Area
2836.00 Post-Development
Type III 24-hr 10-YR NRCC Rainfall=4.81"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Tc Length Slope (min) (feet) (ft/ft) 6.4 50 0.0144 3.4
172
0.1 9.9
Velocity (ft/sec) 0.13
0.0144
0.84
15 0.2000
3.13
237
Capacity (cfs)
Printed 4/26/2017 Page 14
Description Sheet Flow, Sheet Flow Grass: Short n= 0.150 P2= 3.23" Shallow Concentrated Flow, Shallow Concentrated Flow 1 Short Grass Pasture Kv= 7.0 fps Shallow Concentrated Flow, Shallow Concentrated Flow 2 Short Grass Pasture Kv= 7.0 fps
Total
Summary for Subcatchment 103AS: P-DA-3A Runoff
=
0.10 cfs @ 12.41 hrs, Volume=
0.028 af, Depth> 0.26"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 10-YR NRCC Rainfall=4.81" Area (ac) 0.022 0.013 0.670 0.068 0.198 0.020 0.044 0.021 0.236 1.292 1.257 0.035
CN 98 98 30 55 77 39 61 80 30 42
Tc Length (min) (feet) 6.0
Description Paved parking, HSG A Paved parking, HSG D Woods, Good, HSG A Woods, Good, HSG B Woods, Good, HSG D >75% Grass cover, Good, HSG A >75% Grass cover, Good, HSG B >75% Grass cover, Good, HSG D Meadow, non-grazed, HSG A Weighted Average 97.29% Pervious Area 2.71% Impervious Area Slope (ft/ft)
Velocity (ft/sec)
Capacity (cfs)
Description Direct Entry, Minimum
Summary for Subcatchment 103BS: P-DA-3B Runoff
=
3.64 cfs @ 12.29 hrs, Volume=
0.477 af, Depth> 0.83"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 10-YR NRCC Rainfall=4.81"
2836.00 Post-Development
Type III 24-hr 10-YR NRCC Rainfall=4.81"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Area (ac) 0.056 0.252 0.072 0.217 1.924 0.054 0.982 1.191 2.037 0.143 6.928 6.548 0.380 0.072
CN 98 98 98 30 55 39 61 30 58 96 55
Adj
54
Tc Length Slope (min) (feet) (ft/ft) 9.8 50 0.0050
Description Paved parking, HSG A Paved parking, HSG B Unconnected roofs, HSG B Woods, Good, HSG A Woods, Good, HSG B >75% Grass cover, Good, HSG A >75% Grass cover, Good, HSG B Meadow, non-grazed, HSG A Meadow, non-grazed, HSG B Gravel surface, HSG B Weighted Average, UI Adjusted 94.52% Pervious Area 5.48% Impervious Area 18.95% Unconnected Velocity (ft/sec) 0.09
4.3
347
0.0363
1.33
1.8
192
0.0625
1.75
31 0.0955
2.16
0.2 16.1
620
Printed 4/26/2017 Page 15
Capacity (cfs)
Description Sheet Flow, Sheet Flow Grass: Short n= 0.150 P2= 3.23" Shallow Concentrated Flow, Shallow Concentrated Flow 1 Short Grass Pasture Kv= 7.0 fps Shallow Concentrated Flow, Shallow Concentrated Flow 2 Short Grass Pasture Kv= 7.0 fps Shallow Concentrated Flow, Shallow Concentrated Flow 3 Short Grass Pasture Kv= 7.0 fps
Total
Summary for Reach 110R: P-DP-1 [40] Hint: Not Described (Outflow=Inflow) Inflow Area = Inflow = Outflow =
10.114 ac, 0.08% Impervious, Inflow Depth > 0.00" for 10-YR NRCC event 0.00 cfs @ 24.00 hrs, Volume= 0.000 af 0.00 cfs @ 24.00 hrs, Volume= 0.000 af, Atten= 0%, Lag= 0.0 min
Routing by Stor-Ind+Trans method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs
Summary for Reach 120R: P-DP-2 [40] Hint: Not Described (Outflow=Inflow) Inflow Area = Inflow = Outflow =
5.248 ac, 4.10% Impervious, Inflow Depth > 0.63" for 10-YR NRCC event 1.81 cfs @ 12.22 hrs, Volume= 0.277 af 1.81 cfs @ 12.22 hrs, Volume= 0.277 af, Atten= 0%, Lag= 0.0 min
Routing by Stor-Ind+Trans method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs
2836.00 Post-Development
Type III 24-hr 10-YR NRCC Rainfall=4.81"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Printed 4/26/2017 Page 16
Summary for Reach 130R: P-DP-3 [40] Hint: Not Described (Outflow=Inflow) Inflow Area = Inflow = Outflow =
8.220 ac, 5.05% Impervious, Inflow Depth > 0.64" for 10-YR NRCC event 1.85 cfs @ 12.69 hrs, Volume= 0.439 af 1.85 cfs @ 12.69 hrs, Volume= 0.439 af, Atten= 0%, Lag= 0.0 min
Routing by Stor-Ind+Trans method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs
Summary for Pond 101AP: BASIN-1 Inflow Area = Inflow = Outflow = Primary =
8.231 ac, 0.10% Impervious, Inflow Depth > 0.13" for 10-YR NRCC event 0.15 cfs @ 14.94 hrs, Volume= 0.090 af 0.00 cfs @ 0.00 hrs, Volume= 0.000 af, Atten= 100%, Lag= 0.0 min 0.00 cfs @ 0.00 hrs, Volume= 0.000 af
Routing by Stor-Ind method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Peak Elev= 493.70' @ 24.00 hrs Surf.Area= 7,305 sf Storage= 3,901 cf Plug-Flow detention time= (not calculated: initial storage exceeds outflow) Center-of-Mass det. time= (not calculated: no outflow) Volume #1
Invert 493.00'
Elevation (feet) 493.00 494.00 496.00 Device #1
Avail.Storage 30,824 cf
Surf.Area (sq-ft) 3,844 8,790 15,717
Routing Primary
Invert 495.00'
#2
Primary
494.00'
#3
Primary
493.75'
Storage Description Custom Stage Data (Prismatic)Listed below (Recalc)
Inc.Store (cubic-feet) 0 6,317 24,507
Cum.Store (cubic-feet) 0 6,317 30,824
Outlet Devices 20.0' long x 10.0' breadth Broad-Crested Rectangular Weir Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 Coef. (English) 2.49 2.56 2.70 2.69 2.68 2.69 2.67 2.64 12.0" Round Culvert L= 30.0' CPP, mitered to conform to fill, Ke= 0.700 Inlet / Outlet Invert= 494.00' / 493.00' S= 0.0333 '/' Cc= 0.900 n= 0.013 Corrugated PE, smooth interior, Flow Area= 0.79 sf 12.0" Round Culvert L= 30.0' CPP, mitered to conform to fill, Ke= 0.700 Inlet / Outlet Invert= 493.75' / 493.00' S= 0.0250 '/' Cc= 0.900 n= 0.013 Corrugated PE, smooth interior, Flow Area= 0.79 sf
Primary OutFlow Max=0.00 cfs @ 0.00 hrs HW=493.00' (Free Discharge) 1=Broad-Crested Rectangular Weir ( Controls 0.00 cfs) 2=Culvert ( Controls 0.00 cfs) 3=Culvert ( Controls 0.00 cfs)
2836.00 Post-Development
Type III 24-hr 10-YR NRCC Rainfall=4.81"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Printed 4/26/2017 Page 17
Summary for Pond 102P: BASIN-2 Inflow Area = Inflow = Outflow = Primary =
1.350 ac, 1.54 cfs @ 0.06 cfs @ 0.06 cfs @
0.00% Impervious, Inflow Depth > 1.25" for 10-YR NRCC event 12.16 hrs, Volume= 0.141 af 18.05 hrs, Volume= 0.044 af, Atten= 96%, Lag= 353.3 min 18.05 hrs, Volume= 0.044 af
Routing by Stor-Ind method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Peak Elev= 526.40' @ 18.05 hrs Surf.Area= 11,819 sf Storage= 4,455 cf Plug-Flow detention time= 419.6 min calculated for 0.043 af (31% of inflow) Center-of-Mass det. time= 271.6 min ( 1,148.9 - 877.4 ) Volume #1
Invert 526.00'
Elevation (feet) 526.00 528.00 Device #1 #2
Avail.Storage 28,174 cf
Surf.Area (sq-ft) 10,288 17,886
Storage Description Basin (Prismatic) Listed below (Recalc)
Inc.Store (cubic-feet) 0 28,174
Routing Primary
Invert 527.00'
Primary
526.25'
Cum.Store (cubic-feet) 0 28,174
Outlet Devices 20.0' long x 10.0' breadth Riprap Overflow Weir Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 Coef. (English) 2.49 2.56 2.70 2.69 2.68 2.69 2.67 2.64 6.0" Round Culvert L= 60.0' CPP, mitered to conform to fill, Ke= 0.700 Inlet / Outlet Invert= 526.25' / 525.00' S= 0.0208 '/' Cc= 0.900 n= 0.013 Corrugated PE, smooth interior, Flow Area= 0.20 sf
Primary OutFlow Max=0.06 cfs @ 18.05 hrs HW=526.40' (Free Discharge) 1=Riprap Overflow Weir ( Controls 0.00 cfs) 2=Culvert (Inlet Controls 0.06 cfs @ 1.18 fps)
Summary for Pond 103P: BASIN-3 Inflow Area = Inflow = Outflow = Primary =
6.928 ac, 3.64 cfs @ 1.78 cfs @ 1.78 cfs @
5.48% Impervious, Inflow Depth > 0.83" for 10-YR NRCC event 12.29 hrs, Volume= 0.477 af 12.69 hrs, Volume= 0.410 af, Atten= 51%, Lag= 24.1 min 12.69 hrs, Volume= 0.410 af
Routing by Stor-Ind method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Peak Elev= 501.82' @ 12.69 hrs Surf.Area= 7,201 sf Storage= 4,880 cf Plug-Flow detention time= 108.1 min calculated for 0.410 af (86% of inflow) Center-of-Mass det. time= 45.8 min ( 952.9 - 907.2 )
2836.00 Post-Development
Type III 24-hr 10-YR NRCC Rainfall=4.81"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Volume #1
Invert 501.00'
Elevation (feet) 501.00 502.00 504.00 Device #1
Avail.Storage 28,347 cf
Surf.Area (sq-ft) 4,660 7,748 14,395
Routing Primary
Invert 503.00'
#2
Primary
501.42'
#3
Primary
501.42'
Printed 4/26/2017 Page 18
Storage Description Custom Stage Data (Prismatic)Listed below (Recalc)
Inc.Store (cubic-feet) 0 6,204 22,143
Cum.Store (cubic-feet) 0 6,204 28,347
Outlet Devices 20.0' long x 10.0' breadth Broad-Crested Rectangular Weir Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 Coef. (English) 2.49 2.56 2.70 2.69 2.68 2.69 2.67 2.64 12.0" Round Culvert X 2.00 L= 35.0' CPP, mitered to conform to fill, Ke= 0.700 Inlet / Outlet Invert= 501.42' / 500.00' S= 0.0406 '/' Cc= 0.900 n= 0.013 Corrugated PE, smooth interior, Flow Area= 0.79 sf 15.0" Round Culvert L= 35.0' CPP, mitered to conform to fill, Ke= 0.700 Inlet / Outlet Invert= 501.42' / 500.00' S= 0.0406 '/' Cc= 0.900 n= 0.013 Corrugated PE, smooth interior, Flow Area= 1.23 sf
Primary OutFlow Max=1.78 cfs @ 12.69 hrs HW=501.82' (Free Discharge) 1=Broad-Crested Rectangular Weir ( Controls 0.00 cfs) 2=Culvert (Inlet Controls 1.13 cfs @ 1.91 fps) 3=Culvert (Inlet Controls 0.65 cfs @ 1.91 fps)
2836.00 Post-Development
Type III 24-hr 25-YR NRCC Rainfall=6.05"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Printed 4/26/2017 Page 19
Summary for Subcatchment 101AS: P-DA-1A Runoff
=
0.02 cfs @ 15.43 hrs, Volume=
0.012 af, Depth> 0.08"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 25-YR NRCC Rainfall=6.05" Area (ac) 1.479 0.001 0.403 1.883 1.883
CN 30 77 30 30
Tc Length (min) (feet) 6.0
Description Woods, Good, HSG A Woods, Good, HSG D Meadow, non-grazed, HSG A Weighted Average 100.00% Pervious Area Slope (ft/ft)
Velocity (ft/sec)
Capacity (cfs)
Description Direct Entry, Minimum
Summary for Subcatchment 101BS: P-DA-1B Runoff
=
0.86 cfs @ 12.75 hrs, Volume=
0.274 af, Depth> 0.40"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 25-YR NRCC Rainfall=6.05" Area (ac) 0.452 2.021 5.336 0.363 0.008 0.051 8.231 8.223 0.008 0.008
CN 30 55 30 58 98 96 38
Description Woods, Good, HSG A Woods, Good, HSG B Meadow, non-grazed, HSG A Meadow, non-grazed, HSG B Unconnected pavement, HSG B Gravel surface, HSG B Weighted Average 99.90% Pervious Area 0.10% Impervious Area 100.00% Unconnected
Tc Length Slope (min) (feet) (ft/ft) 13.0 50 0.0690
Velocity (ft/sec) 0.06
12.8
292
0.0231
0.38
5.4
260
0.1045
0.81
31.2
602
Total
Capacity (cfs)
Description Sheet Flow, Sheet Flow Woods: Dense underbrush n= 0.800 P2= 3.23" Shallow Concentrated Flow, Shallow Concentrated Flow 1 Forest w/Heavy Litter Kv= 2.5 fps Shallow Concentrated Flow, Shallow Concentrated Flow 2 Forest w/Heavy Litter Kv= 2.5 fps
2836.00 Post-Development
Type III 24-hr 25-YR NRCC Rainfall=6.05"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Printed 4/26/2017 Page 20
Summary for Subcatchment 102AS: P-DA-2A Runoff
=
4.10 cfs @ 12.19 hrs, Volume=
0.426 af, Depth> 1.31"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 25-YR NRCC Rainfall=6.05" Area (ac) 0.105 0.053 0.057 1.156 0.773 0.117 1.205 0.432 3.898 3.683 0.215 0.162
CN 98 98 98 30 55 77 61 58 53
Adj
52
Tc Length Slope (min) (feet) (ft/ft) 3.8 50 0.0514
Description Unconnected pavement, HSG B Water Surface, HSG B Unconnected roofs, HSG B Woods, Good, HSG A Woods, Good, HSG B Woods, Good, HSG D >75% Grass cover, Good, HSG B Meadow, non-grazed, HSG B Weighted Average, UI Adjusted 94.48% Pervious Area 5.52% Impervious Area 75.35% Unconnected Velocity (ft/sec) 0.22
4.3
208
0.0133
0.81
1.3
168
0.0954
2.16
2.2
121
0.0165
0.90
11.6
547
Total
Capacity (cfs)
Description Sheet Flow, Sheet Flow Grass: Short n= 0.150 P2= 3.23" Shallow Concentrated Flow, Shallow Concentrated Flow 1 Short Grass Pasture Kv= 7.0 fps Shallow Concentrated Flow, Shallow Concentrated Flow 2 Short Grass Pasture Kv= 7.0 fps Shallow Concentrated Flow, Shallow Concentrated Flow 3 Short Grass Pasture Kv= 7.0 fps
Summary for Subcatchment 102BS: P-DA-2B Runoff
=
2.66 cfs @ 12.15 hrs, Volume=
0.229 af, Depth> 2.03"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 25-YR NRCC Rainfall=6.05" Area (ac) 0.106 1.138 0.106 1.350 1.350
CN 55 58 96 61
Description Woods, Good, HSG B Meadow, non-grazed, HSG B Gravel surface, HSG B Weighted Average 100.00% Pervious Area
2836.00 Post-Development
Type III 24-hr 25-YR NRCC Rainfall=6.05"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Tc Length Slope (min) (feet) (ft/ft) 6.4 50 0.0144 3.4
172
0.1 9.9
Velocity (ft/sec) 0.13
0.0144
0.84
15 0.2000
3.13
237
Capacity (cfs)
Printed 4/26/2017 Page 21
Description Sheet Flow, Sheet Flow Grass: Short n= 0.150 P2= 3.23" Shallow Concentrated Flow, Shallow Concentrated Flow 1 Short Grass Pasture Kv= 7.0 fps Shallow Concentrated Flow, Shallow Concentrated Flow 2 Short Grass Pasture Kv= 7.0 fps
Total
Summary for Subcatchment 103AS: P-DA-3A Runoff
=
0.43 cfs @ 12.17 hrs, Volume=
0.068 af, Depth> 0.63"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 25-YR NRCC Rainfall=6.05" Area (ac) 0.022 0.013 0.670 0.068 0.198 0.020 0.044 0.021 0.236 1.292 1.257 0.035
CN 98 98 30 55 77 39 61 80 30 42
Tc Length (min) (feet) 6.0
Description Paved parking, HSG A Paved parking, HSG D Woods, Good, HSG A Woods, Good, HSG B Woods, Good, HSG D >75% Grass cover, Good, HSG A >75% Grass cover, Good, HSG B >75% Grass cover, Good, HSG D Meadow, non-grazed, HSG A Weighted Average 97.29% Pervious Area 2.71% Impervious Area Slope (ft/ft)
Velocity (ft/sec)
Capacity (cfs)
Description Direct Entry, Minimum
Summary for Subcatchment 103BS: P-DA-3B Runoff
=
7.58 cfs @ 12.26 hrs, Volume=
0.844 af, Depth> 1.46"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 25-YR NRCC Rainfall=6.05"
2836.00 Post-Development
Type III 24-hr 25-YR NRCC Rainfall=6.05"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Area (ac) 0.056 0.252 0.072 0.217 1.924 0.054 0.982 1.191 2.037 0.143 6.928 6.548 0.380 0.072
CN 98 98 98 30 55 39 61 30 58 96 55
Adj
54
Tc Length Slope (min) (feet) (ft/ft) 9.8 50 0.0050
Description Paved parking, HSG A Paved parking, HSG B Unconnected roofs, HSG B Woods, Good, HSG A Woods, Good, HSG B >75% Grass cover, Good, HSG A >75% Grass cover, Good, HSG B Meadow, non-grazed, HSG A Meadow, non-grazed, HSG B Gravel surface, HSG B Weighted Average, UI Adjusted 94.52% Pervious Area 5.48% Impervious Area 18.95% Unconnected Velocity (ft/sec) 0.09
4.3
347
0.0363
1.33
1.8
192
0.0625
1.75
31 0.0955
2.16
0.2 16.1
620
Printed 4/26/2017 Page 22
Capacity (cfs)
Description Sheet Flow, Sheet Flow Grass: Short n= 0.150 P2= 3.23" Shallow Concentrated Flow, Shallow Concentrated Flow 1 Short Grass Pasture Kv= 7.0 fps Shallow Concentrated Flow, Shallow Concentrated Flow 2 Short Grass Pasture Kv= 7.0 fps Shallow Concentrated Flow, Shallow Concentrated Flow 3 Short Grass Pasture Kv= 7.0 fps
Total
Summary for Reach 110R: P-DP-1 [40] Hint: Not Described (Outflow=Inflow) Inflow Area = Inflow = Outflow =
10.114 ac, 0.08% Impervious, Inflow Depth > 0.18" for 25-YR NRCC event 0.26 cfs @ 17.39 hrs, Volume= 0.153 af 0.26 cfs @ 17.39 hrs, Volume= 0.153 af, Atten= 0%, Lag= 0.0 min
Routing by Stor-Ind+Trans method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs
Summary for Reach 120R: P-DP-2 [40] Hint: Not Described (Outflow=Inflow) Inflow Area = Inflow = Outflow =
5.248 ac, 4.10% Impervious, Inflow Depth > 1.25" for 25-YR NRCC event 4.10 cfs @ 12.19 hrs, Volume= 0.547 af 4.10 cfs @ 12.19 hrs, Volume= 0.547 af, Atten= 0%, Lag= 0.0 min
Routing by Stor-Ind+Trans method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs
2836.00 Post-Development
Type III 24-hr 25-YR NRCC Rainfall=6.05"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Printed 4/26/2017 Page 23
Summary for Reach 130R: P-DP-3 [40] Hint: Not Described (Outflow=Inflow) Inflow Area = Inflow = Outflow =
8.220 ac, 5.05% Impervious, Inflow Depth > 1.23" for 25-YR NRCC event 5.19 cfs @ 12.51 hrs, Volume= 0.842 af 5.19 cfs @ 12.51 hrs, Volume= 0.842 af, Atten= 0%, Lag= 0.0 min
Routing by Stor-Ind+Trans method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs
Summary for Pond 101AP: BASIN-1 Inflow Area = Inflow = Outflow = Primary =
8.231 ac, 0.86 cfs @ 0.24 cfs @ 0.24 cfs @
0.10% Impervious, Inflow Depth > 0.40" for 25-YR NRCC event 12.75 hrs, Volume= 0.274 af 17.44 hrs, Volume= 0.140 af, Atten= 72%, Lag= 281.9 min 17.44 hrs, Volume= 0.140 af
Routing by Stor-Ind method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Peak Elev= 494.01' @ 17.44 hrs Surf.Area= 8,808 sf Storage= 6,364 cf Plug-Flow detention time= 332.1 min calculated for 0.140 af (51% of inflow) Center-of-Mass det. time= 176.5 min ( 1,159.5 - 983.0 ) Volume #1
Invert 493.00'
Elevation (feet) 493.00 494.00 496.00 Device #1
Avail.Storage 30,824 cf
Surf.Area (sq-ft) 3,844 8,790 15,717
Routing Primary
Invert 495.00'
#2
Primary
494.00'
#3
Primary
493.75'
Storage Description Custom Stage Data (Prismatic)Listed below (Recalc)
Inc.Store (cubic-feet) 0 6,317 24,507
Cum.Store (cubic-feet) 0 6,317 30,824
Outlet Devices 20.0' long x 10.0' breadth Broad-Crested Rectangular Weir Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 Coef. (English) 2.49 2.56 2.70 2.69 2.68 2.69 2.67 2.64 12.0" Round Culvert L= 30.0' CPP, mitered to conform to fill, Ke= 0.700 Inlet / Outlet Invert= 494.00' / 493.00' S= 0.0333 '/' Cc= 0.900 n= 0.013 Corrugated PE, smooth interior, Flow Area= 0.79 sf 12.0" Round Culvert L= 30.0' CPP, mitered to conform to fill, Ke= 0.700 Inlet / Outlet Invert= 493.75' / 493.00' S= 0.0250 '/' Cc= 0.900 n= 0.013 Corrugated PE, smooth interior, Flow Area= 0.79 sf
Primary OutFlow Max=0.24 cfs @ 17.44 hrs HW=494.01' (Free Discharge) 1=Broad-Crested Rectangular Weir ( Controls 0.00 cfs) 2=Culvert (Inlet Controls 0.00 cfs @ 0.22 fps) 3=Culvert (Inlet Controls 0.24 cfs @ 1.52 fps)
2836.00 Post-Development
Type III 24-hr 25-YR NRCC Rainfall=6.05"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Printed 4/26/2017 Page 24
Summary for Pond 102P: BASIN-2 Inflow Area = Inflow = Outflow = Primary =
1.350 ac, 2.66 cfs @ 0.17 cfs @ 0.17 cfs @
0.00% Impervious, Inflow Depth > 2.03" for 25-YR NRCC event 12.15 hrs, Volume= 0.229 af 15.45 hrs, Volume= 0.121 af, Atten= 93%, Lag= 198.0 min 15.45 hrs, Volume= 0.121 af
Routing by Stor-Ind method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Peak Elev= 526.52' @ 15.45 hrs Surf.Area= 12,279 sf Storage= 5,914 cf Plug-Flow detention time= 326.6 min calculated for 0.120 af (53% of inflow) Center-of-Mass det. time= 201.0 min ( 1,063.0 - 862.0 ) Volume #1
Invert 526.00'
Elevation (feet) 526.00 528.00 Device #1 #2
Avail.Storage 28,174 cf
Surf.Area (sq-ft) 10,288 17,886
Storage Description Basin (Prismatic) Listed below (Recalc)
Inc.Store (cubic-feet) 0 28,174
Routing Primary
Invert 527.00'
Primary
526.25'
Cum.Store (cubic-feet) 0 28,174
Outlet Devices 20.0' long x 10.0' breadth Riprap Overflow Weir Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 Coef. (English) 2.49 2.56 2.70 2.69 2.68 2.69 2.67 2.64 6.0" Round Culvert L= 60.0' CPP, mitered to conform to fill, Ke= 0.700 Inlet / Outlet Invert= 526.25' / 525.00' S= 0.0208 '/' Cc= 0.900 n= 0.013 Corrugated PE, smooth interior, Flow Area= 0.20 sf
Primary OutFlow Max=0.17 cfs @ 15.45 hrs HW=526.52' (Free Discharge) 1=Riprap Overflow Weir ( Controls 0.00 cfs) 2=Culvert (Inlet Controls 0.17 cfs @ 1.57 fps)
Summary for Pond 103P: BASIN-3 Inflow Area = Inflow = Outflow = Primary =
6.928 ac, 7.58 cfs @ 4.93 cfs @ 4.93 cfs @
5.48% Impervious, Inflow Depth > 1.46" for 25-YR NRCC event 12.26 hrs, Volume= 0.844 af 12.53 hrs, Volume= 0.774 af, Atten= 35%, Lag= 16.1 min 12.53 hrs, Volume= 0.774 af
Routing by Stor-Ind method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Peak Elev= 502.14' @ 12.53 hrs Surf.Area= 8,206 sf Storage= 7,303 cf Plug-Flow detention time= 69.8 min calculated for 0.772 af (91% of inflow) Center-of-Mass det. time= 29.5 min ( 915.9 - 886.4 )
2836.00 Post-Development
Type III 24-hr 25-YR NRCC Rainfall=6.05"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Volume #1
Invert 501.00'
Elevation (feet) 501.00 502.00 504.00 Device #1
Avail.Storage 28,347 cf
Surf.Area (sq-ft) 4,660 7,748 14,395
Routing Primary
Invert 503.00'
#2
Primary
501.42'
#3
Primary
501.42'
Printed 4/26/2017 Page 25
Storage Description Custom Stage Data (Prismatic)Listed below (Recalc)
Inc.Store (cubic-feet) 0 6,204 22,143
Cum.Store (cubic-feet) 0 6,204 28,347
Outlet Devices 20.0' long x 10.0' breadth Broad-Crested Rectangular Weir Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 Coef. (English) 2.49 2.56 2.70 2.69 2.68 2.69 2.67 2.64 12.0" Round Culvert X 2.00 L= 35.0' CPP, mitered to conform to fill, Ke= 0.700 Inlet / Outlet Invert= 501.42' / 500.00' S= 0.0406 '/' Cc= 0.900 n= 0.013 Corrugated PE, smooth interior, Flow Area= 0.79 sf 15.0" Round Culvert L= 35.0' CPP, mitered to conform to fill, Ke= 0.700 Inlet / Outlet Invert= 501.42' / 500.00' S= 0.0406 '/' Cc= 0.900 n= 0.013 Corrugated PE, smooth interior, Flow Area= 1.23 sf
Primary OutFlow Max=4.91 cfs @ 12.53 hrs HW=502.14' (Free Discharge) 1=Broad-Crested Rectangular Weir ( Controls 0.00 cfs) 2=Culvert (Inlet Controls 3.06 cfs @ 2.54 fps) 3=Culvert (Inlet Controls 1.85 cfs @ 2.54 fps)
2836.00 Post-Development
Type III 24-hr 100-YR NRCC Rainfall=8.59"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Printed 4/26/2017 Page 26
Summary for Subcatchment 101AS: P-DA-1A Runoff
=
0.38 cfs @ 12.37 hrs, Volume=
0.088 af, Depth> 0.56"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 100-YR NRCC Rainfall=8.59" Area (ac) 1.479 0.001 0.403 1.883 1.883
CN 30 77 30 30
Tc Length (min) (feet) 6.0
Description Woods, Good, HSG A Woods, Good, HSG D Meadow, non-grazed, HSG A Weighted Average 100.00% Pervious Area Slope (ft/ft)
Velocity (ft/sec)
Capacity (cfs)
Description Direct Entry, Minimum
Summary for Subcatchment 101BS: P-DA-1B Runoff
=
5.05 cfs @ 12.57 hrs, Volume=
0.889 af, Depth> 1.30"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 100-YR NRCC Rainfall=8.59" Area (ac) 0.452 2.021 5.336 0.363 0.008 0.051 8.231 8.223 0.008 0.008
CN 30 55 30 58 98 96 38
Description Woods, Good, HSG A Woods, Good, HSG B Meadow, non-grazed, HSG A Meadow, non-grazed, HSG B Unconnected pavement, HSG B Gravel surface, HSG B Weighted Average 99.90% Pervious Area 0.10% Impervious Area 100.00% Unconnected
Tc Length Slope (min) (feet) (ft/ft) 13.0 50 0.0690
Velocity (ft/sec) 0.06
12.8
292
0.0231
0.38
5.4
260
0.1045
0.81
31.2
602
Total
Capacity (cfs)
Description Sheet Flow, Sheet Flow Woods: Dense underbrush n= 0.800 P2= 3.23" Shallow Concentrated Flow, Shallow Concentrated Flow 1 Forest w/Heavy Litter Kv= 2.5 fps Shallow Concentrated Flow, Shallow Concentrated Flow 2 Forest w/Heavy Litter Kv= 2.5 fps
2836.00 Post-Development
Type III 24-hr 100-YR NRCC Rainfall=8.59"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Printed 4/26/2017 Page 27
Summary for Subcatchment 102AS: P-DA-2A Runoff
=
10.17 cfs @ 12.17 hrs, Volume=
0.922 af, Depth> 2.84"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 100-YR NRCC Rainfall=8.59" Area (ac) 0.105 0.053 0.057 1.156 0.773 0.117 1.205 0.432 3.898 3.683 0.215 0.162
CN 98 98 98 30 55 77 61 58 53
Adj
52
Tc Length Slope (min) (feet) (ft/ft) 3.8 50 0.0514
Description Unconnected pavement, HSG B Water Surface, HSG B Unconnected roofs, HSG B Woods, Good, HSG A Woods, Good, HSG B Woods, Good, HSG D >75% Grass cover, Good, HSG B Meadow, non-grazed, HSG B Weighted Average, UI Adjusted 94.48% Pervious Area 5.52% Impervious Area 75.35% Unconnected Velocity (ft/sec) 0.22
4.3
208
0.0133
0.81
1.3
168
0.0954
2.16
2.2
121
0.0165
0.90
11.6
547
Total
Capacity (cfs)
Description Sheet Flow, Sheet Flow Grass: Short n= 0.150 P2= 3.23" Shallow Concentrated Flow, Shallow Concentrated Flow 1 Short Grass Pasture Kv= 7.0 fps Shallow Concentrated Flow, Shallow Concentrated Flow 2 Short Grass Pasture Kv= 7.0 fps Shallow Concentrated Flow, Shallow Concentrated Flow 3 Short Grass Pasture Kv= 7.0 fps
Summary for Subcatchment 102BS: P-DA-2B Runoff
=
5.30 cfs @ 12.15 hrs, Volume=
0.438 af, Depth> 3.89"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 100-YR NRCC Rainfall=8.59" Area (ac) 0.106 1.138 0.106 1.350 1.350
CN 55 58 96 61
Description Woods, Good, HSG B Meadow, non-grazed, HSG B Gravel surface, HSG B Weighted Average 100.00% Pervious Area
2836.00 Post-Development
Type III 24-hr 100-YR NRCC Rainfall=8.59"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Tc Length Slope (min) (feet) (ft/ft) 6.4 50 0.0144 3.4
172
0.1 9.9
Velocity (ft/sec) 0.13
0.0144
0.84
15 0.2000
3.13
237
Capacity (cfs)
Printed 4/26/2017 Page 28
Description Sheet Flow, Sheet Flow Grass: Short n= 0.150 P2= 3.23" Shallow Concentrated Flow, Shallow Concentrated Flow 1 Short Grass Pasture Kv= 7.0 fps Shallow Concentrated Flow, Shallow Concentrated Flow 2 Short Grass Pasture Kv= 7.0 fps
Total
Summary for Subcatchment 103AS: P-DA-3A Runoff
=
2.10 cfs @ 12.11 hrs, Volume=
0.186 af, Depth> 1.73"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 100-YR NRCC Rainfall=8.59" Area (ac) 0.022 0.013 0.670 0.068 0.198 0.020 0.044 0.021 0.236 1.292 1.257 0.035
CN 98 98 30 55 77 39 61 80 30 42
Tc Length (min) (feet) 6.0
Description Paved parking, HSG A Paved parking, HSG D Woods, Good, HSG A Woods, Good, HSG B Woods, Good, HSG D >75% Grass cover, Good, HSG A >75% Grass cover, Good, HSG B >75% Grass cover, Good, HSG D Meadow, non-grazed, HSG A Weighted Average 97.29% Pervious Area 2.71% Impervious Area Slope (ft/ft)
Velocity (ft/sec)
Capacity (cfs)
Description Direct Entry, Minimum
Summary for Subcatchment 103BS: P-DA-3B Runoff
=
17.53 cfs @ 12.24 hrs, Volume=
1.771 af, Depth> 3.07"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 100-YR NRCC Rainfall=8.59"
2836.00 Post-Development
Type III 24-hr 100-YR NRCC Rainfall=8.59"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Area (ac) 0.056 0.252 0.072 0.217 1.924 0.054 0.982 1.191 2.037 0.143 6.928 6.548 0.380 0.072
CN 98 98 98 30 55 39 61 30 58 96 55
Adj
54
Tc Length Slope (min) (feet) (ft/ft) 9.8 50 0.0050
Description Paved parking, HSG A Paved parking, HSG B Unconnected roofs, HSG B Woods, Good, HSG A Woods, Good, HSG B >75% Grass cover, Good, HSG A >75% Grass cover, Good, HSG B Meadow, non-grazed, HSG A Meadow, non-grazed, HSG B Gravel surface, HSG B Weighted Average, UI Adjusted 94.52% Pervious Area 5.48% Impervious Area 18.95% Unconnected Velocity (ft/sec) 0.09
4.3
347
0.0363
1.33
1.8
192
0.0625
1.75
31 0.0955
2.16
0.2 16.1
620
Printed 4/26/2017 Page 29
Capacity (cfs)
Description Sheet Flow, Sheet Flow Grass: Short n= 0.150 P2= 3.23" Shallow Concentrated Flow, Shallow Concentrated Flow 1 Short Grass Pasture Kv= 7.0 fps Shallow Concentrated Flow, Shallow Concentrated Flow 2 Short Grass Pasture Kv= 7.0 fps Shallow Concentrated Flow, Shallow Concentrated Flow 3 Short Grass Pasture Kv= 7.0 fps
Total
Summary for Reach 110R: P-DP-1 [40] Hint: Not Described (Outflow=Inflow) Inflow Area = Inflow = Outflow =
10.114 ac, 0.08% Impervious, Inflow Depth > 0.98" for 100-YR NRCC event 2.24 cfs @ 13.27 hrs, Volume= 0.825 af 2.24 cfs @ 13.27 hrs, Volume= 0.825 af, Atten= 0%, Lag= 0.0 min
Routing by Stor-Ind+Trans method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs
Summary for Reach 120R: P-DP-2 [40] Hint: Not Described (Outflow=Inflow) Inflow Area = Inflow = Outflow =
5.248 ac, 4.10% Impervious, Inflow Depth > 2.82" for 100-YR NRCC event 10.19 cfs @ 12.18 hrs, Volume= 1.235 af 10.19 cfs @ 12.18 hrs, Volume= 1.235 af, Atten= 0%, Lag= 0.0 min
Routing by Stor-Ind+Trans method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs
2836.00 Post-Development
Type III 24-hr 100-YR NRCC Rainfall=8.59"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Printed 4/26/2017 Page 30
Summary for Reach 130R: P-DP-3 [40] Hint: Not Described (Outflow=Inflow) Inflow Area = Inflow = Outflow =
8.220 ac, 5.05% Impervious, Inflow Depth > 2.74" for 100-YR NRCC event 12.24 cfs @ 12.43 hrs, Volume= 1.880 af 12.24 cfs @ 12.43 hrs, Volume= 1.880 af, Atten= 0%, Lag= 0.0 min
Routing by Stor-Ind+Trans method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs
Summary for Pond 101AP: BASIN-1 Inflow Area = Inflow = Outflow = Primary =
8.231 ac, 5.05 cfs @ 2.07 cfs @ 2.07 cfs @
0.10% Impervious, Inflow Depth > 1.30" for 100-YR NRCC event 12.57 hrs, Volume= 0.889 af 13.27 hrs, Volume= 0.736 af, Atten= 59%, Lag= 42.5 min 13.27 hrs, Volume= 0.736 af
Routing by Stor-Ind method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Peak Elev= 494.43' @ 13.27 hrs Surf.Area= 10,296 sf Storage= 10,466 cf Plug-Flow detention time= 134.8 min calculated for 0.735 af (83% of inflow) Center-of-Mass det. time= 63.0 min ( 988.8 - 925.8 ) Volume #1
Invert 493.00'
Elevation (feet) 493.00 494.00 496.00 Device #1
Avail.Storage 30,824 cf
Surf.Area (sq-ft) 3,844 8,790 15,717
Routing Primary
Invert 495.00'
#2
Primary
494.00'
#3
Primary
493.75'
Storage Description Custom Stage Data (Prismatic)Listed below (Recalc)
Inc.Store (cubic-feet) 0 6,317 24,507
Cum.Store (cubic-feet) 0 6,317 30,824
Outlet Devices 20.0' long x 10.0' breadth Broad-Crested Rectangular Weir Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 Coef. (English) 2.49 2.56 2.70 2.69 2.68 2.69 2.67 2.64 12.0" Round Culvert L= 30.0' CPP, mitered to conform to fill, Ke= 0.700 Inlet / Outlet Invert= 494.00' / 493.00' S= 0.0333 '/' Cc= 0.900 n= 0.013 Corrugated PE, smooth interior, Flow Area= 0.79 sf 12.0" Round Culvert L= 30.0' CPP, mitered to conform to fill, Ke= 0.700 Inlet / Outlet Invert= 493.75' / 493.00' S= 0.0250 '/' Cc= 0.900 n= 0.013 Corrugated PE, smooth interior, Flow Area= 0.79 sf
Primary OutFlow Max=2.07 cfs @ 13.27 hrs HW=494.43' (Free Discharge) 1=Broad-Crested Rectangular Weir ( Controls 0.00 cfs) 2=Culvert (Inlet Controls 0.65 cfs @ 1.98 fps) 3=Culvert (Inlet Controls 1.42 cfs @ 2.49 fps)
2836.00 Post-Development
Type III 24-hr 100-YR NRCC Rainfall=8.59"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Printed 4/26/2017 Page 31
Summary for Pond 102P: BASIN-2 Inflow Area = Inflow = Outflow = Primary =
1.350 ac, 5.30 cfs @ 0.49 cfs @ 0.49 cfs @
0.00% Impervious, Inflow Depth > 3.89" for 100-YR NRCC event 12.15 hrs, Volume= 0.438 af 13.76 hrs, Volume= 0.313 af, Atten= 91%, Lag= 96.7 min 13.76 hrs, Volume= 0.313 af
Routing by Stor-Ind method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Peak Elev= 526.84' @ 13.76 hrs Surf.Area= 13,478 sf Storage= 9,976 cf Plug-Flow detention time= 264.8 min calculated for 0.313 af (71% of inflow) Center-of-Mass det. time= 168.8 min ( 1,011.6 - 842.8 ) Volume #1
Invert 526.00'
Elevation (feet) 526.00 528.00 Device #1 #2
Avail.Storage 28,174 cf
Surf.Area (sq-ft) 10,288 17,886
Storage Description Basin (Prismatic) Listed below (Recalc)
Inc.Store (cubic-feet) 0 28,174
Routing Primary
Invert 527.00'
Primary
526.25'
Cum.Store (cubic-feet) 0 28,174
Outlet Devices 20.0' long x 10.0' breadth Riprap Overflow Weir Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 Coef. (English) 2.49 2.56 2.70 2.69 2.68 2.69 2.67 2.64 6.0" Round Culvert L= 60.0' CPP, mitered to conform to fill, Ke= 0.700 Inlet / Outlet Invert= 526.25' / 525.00' S= 0.0208 '/' Cc= 0.900 n= 0.013 Corrugated PE, smooth interior, Flow Area= 0.20 sf
Primary OutFlow Max=0.49 cfs @ 13.76 hrs HW=526.84' (Free Discharge) 1=Riprap Overflow Weir ( Controls 0.00 cfs) 2=Culvert (Inlet Controls 0.49 cfs @ 2.48 fps)
Summary for Pond 103P: BASIN-3 Inflow Area = Inflow = Outflow = Primary =
6.928 ac, 17.53 cfs @ 11.36 cfs @ 11.36 cfs @
5.48% Impervious, Inflow Depth > 3.07" for 100-YR NRCC event 12.24 hrs, Volume= 1.771 af 12.48 hrs, Volume= 1.694 af, Atten= 35%, Lag= 14.4 min 12.48 hrs, Volume= 1.694 af
Routing by Stor-Ind method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Peak Elev= 502.89' @ 12.48 hrs Surf.Area= 10,704 sf Storage= 14,409 cf Plug-Flow detention time= 43.8 min calculated for 1.694 af (96% of inflow) Center-of-Mass det. time= 20.8 min ( 883.8 - 863.0 )
2836.00 Post-Development
Type III 24-hr 100-YR NRCC Rainfall=8.59"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Volume #1
Invert 501.00'
Elevation (feet) 501.00 502.00 504.00 Device #1
Avail.Storage 28,347 cf
Surf.Area (sq-ft) 4,660 7,748 14,395
Routing Primary
Invert 503.00'
#2
Primary
501.42'
#3
Primary
501.42'
Printed 4/26/2017 Page 32
Storage Description Custom Stage Data (Prismatic)Listed below (Recalc)
Inc.Store (cubic-feet) 0 6,204 22,143
Cum.Store (cubic-feet) 0 6,204 28,347
Outlet Devices 20.0' long x 10.0' breadth Broad-Crested Rectangular Weir Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 Coef. (English) 2.49 2.56 2.70 2.69 2.68 2.69 2.67 2.64 12.0" Round Culvert X 2.00 L= 35.0' CPP, mitered to conform to fill, Ke= 0.700 Inlet / Outlet Invert= 501.42' / 500.00' S= 0.0406 '/' Cc= 0.900 n= 0.013 Corrugated PE, smooth interior, Flow Area= 0.79 sf 15.0" Round Culvert L= 35.0' CPP, mitered to conform to fill, Ke= 0.700 Inlet / Outlet Invert= 501.42' / 500.00' S= 0.0406 '/' Cc= 0.900 n= 0.013 Corrugated PE, smooth interior, Flow Area= 1.23 sf
Primary OutFlow Max=11.35 cfs @ 12.48 hrs HW=502.89' (Free Discharge) 1=Broad-Crested Rectangular Weir ( Controls 0.00 cfs) 2=Culvert (Inlet Controls 6.56 cfs @ 4.18 fps) 3=Culvert (Inlet Controls 4.78 cfs @ 3.90 fps)
Appendix D Drawdown & Riprap-Sizing Calculation
BEALS+THOMAS Standard 3: Drawdown
Rv (K) (Bottom Area)
Drawdown Time =
where:
Rv = Storage Volume Below Outlet [Ac-ft] K= Infiltration Rate [in/hr] Bottom Area= Bottom Area of Recharge System [Ac]
Basin 1 Rv =
0.107 Ac-ft
K=
0.270 in/hr
Bottom Area =
0.088 Acres
Drawdown Time =
53.856 Hours
(Mapped as HSG "A" & "B"; Rawls Rate for HSG "C" Soils) < 72 Hours, Design is in compliance with the standard.
Basin 2 Rv =
0.075 Ac-ft
K=
0.270 in/hr
Bottom Area =
0.236 Acres
Drawdown Time =
14.070 Hours
(Mapped as HSG "A" & "B"; Rawls Rate for HSG "C" Soils) < 72 Hours, Design is in compliance with the standard.
Basin 3 Rv =
0.062 Ac-ft
K=
0.270 in/hr
Bottom Area =
0.107 Acres
Drawdown Time =
25.904 Hours
(Mapped as HSG "A" & "B"; Rawls Rate for HSG "C" Soils) < 72 Hours, Design is in compliance with the standard.
Note: 1. The infiltration BMPs have been designed to fully drain within 72 hours, therefore the proposed stormwater management design is in compliance with Standard 3 . 2. Infiltration Rate based on Volume 3, Chapter 1, Table 2.3.3 Rawls Rates from the 2008 MA DEP Stormwater Management Handbook. JOB NO. JOB:
283600SWM0001.xlsx
2836.00 CEC Solar #1206, LLC
COMPUTED BY: DATE:
TJM 08/09/17
CHECKED BY: DATE:
BEALS+THOMAS Riprap Apron Sizing
Median Stone Sizing: Where: D0 = Maximum Inside Pipe Diameter (ft) D50 = Median Riprap Diameter (ft) Q = Peak Discharge Rate from Hydraulic Design (cfs) TW = Tailwater Depth (ft); (Use 0.4D0 if TW is unknown, max 1.0Do) 2
g = Gravitational Acceleration Constant = 32.2 ft/s
Apron Sizing: D50 [In]
Apron Length (L) [ft}
Apron Depth [In]
Apron Width At Beginning
Apron Width At End
5 6 10 14 20 22
4D0 4D0 5D0 6D0 7D0 8D0
3.5D50 3.3D50 2.4D50 2.2D50 2.0D50 2.0D50
3D0 3D0 3D0 3D0 3D0 3D0
3D0 + ⅔L 3D0 + ⅔L 3D0 + ⅔L 3D0 + ⅔L 3D0 + ⅔L 3D0 + ⅔L
FLARED END SECTIONS
PIPE DIAMETER (D0) (FEET)
25-YEAR STORM FLOW (Q) (CFS)
12"@Basin #1 (2) 6"@Basin #2 (1) 12"@Basin #3 (2) 15" @Basin #3 (1)
1.00 0.50 1.00 1.25
0.24 0.17 3.06 1.85
MEDIAN STONE TAILWATER DIAMETER (TW) [ft] (D50) (INCHES) 0.4 0.2 0.4 0.5
5 5 5 5
APRON LENGTH (L) (FEET)
APRON DEPTH [In]
APRON WIDTH AT BEGINING (W1) [ft]
APRON WIDTH AT END (W2) [ft]
4.00 2.00 4.00 5.00
17.5 17.5 17.5 17.5
3.0 1.5 3.0 3.8
5.7 2.8 5.7 7.1
Notes [1] Calculations performed in accordance with Hydraulic Engineering Circular No. 14, Third Edition; Hydraulic Design of Energy Dissipaters for Culverts and Channels, dated July 2006. [2] Pipe shall extend 1 foot into riprap. [3] For maximum pipe size of 60". JOB NO. JOB:
2836 CEC Solar #1206
283600SWM0001.xlsx
COMPUTED BY: DATE:
TJM 08/14/17
CHECKED BY: DATE:
Appendix E Site Owner’s Manual
SITE OWNER’S MANUAL CEC Solar #1206, LLC 147 Lumber Street Hopkinton, Massachusetts
Prepared for: CEC Solar #1144, LLC c/o Clean Energy Collective 146 West Boylston Drive, 3rd Floor Worcester, MA 01606
Presented by:
BEALS+THOMAS BEALS AND THOMAS, INC. Reservoir Corporate Center 144 Turnpike Road Southborough, MA 01772-2104
August 10, 2017
283600P002
CEC Solar #1206, LLC Site Owner’s Manual Hopkinton, Massachusetts 283600RP002
TABLE OF CONTENTS 1.0
INTRODUCTION .......................................................................................................................................... 1-1
2.0
SITE OWNER’S AGREEMENT ................................................................................................................. 2-1
2.1 2.2 2.3 2.4 3.0
LONG-TERM POLLUTION PREVENTION PLAN ................................................................................ 3-1
3.1 3.2 3.3 3.4 3.5 3.6 3.7 3.8 4.0
OPERATION AND MAINTENANCE COMPLIANCE STATEMENT........................................................................ 2-1 STORMWATER MAINTENANCE EASEMENTS ................................................................................................. 2-1 RECORD KEEPING ........................................................................................................................................ 2-1 TRAINING ..................................................................................................................................................... 2-2
STORAGE OF MATERIALS AND WASTE ......................................................................................................... 3-1 VEHICLE WASHING ...................................................................................................................................... 3-1 ROUTINE INSPECTIONS AND MAINTENANCE OF STORMWATER BMPS ......................................................... 3-1 SPILL PREVENTION AND RESPONSE .............................................................................................................. 3-1 VEGETATION MAINTENANCE PLAN.............................................................................................................. 3-1 STORAGE AND USE OF FERTILIZERS, HERBICIDES, AND PESTICIDES ............................................................ 3-2 SNOW REMOVAL PLAN ................................................................................................................................ 3-2 NUTRIENT MANAGEMENT PLAN .................................................................................................................. 3-2
LONG-TERM OPERATION AND MAINTENANCE PLAN ................................................................... 4-1
4.1 STORMWATER MANAGEMENT SYSTEM COMPONENTS ................................................................................. 4-1 4.2 INSPECTION AND MAINTENANCE SCHEDULES .............................................................................................. 4-1 4.2.1 Conveyance Swales ............................................................................................................................ 4-1 4.2.2 Infiltration Basins .............................................................................................................................. 4-2 4.2.3 Stormwater Outfalls ........................................................................................................................... 4-2 4.3 ESTIMATED OPERATION AND MAINTENANCE BUDGET ................................................................................ 4-3 4.4 PUBLIC SAFETY FEATURES .......................................................................................................................... 4-3
FIGURES FIGURE 1: SITE PLANS APPENDICES APPENDIX A: OPERATION AND MAINTENANCE LOG APPENDIX B: LIST OF EMERGENCY CONTACTS APPENDIX C: PROPRIETARY SEPARATOR TECHNICAL MANUAL
Table of Contents
i
CEC Solar #1206, LLC Site Owner’s Manual Hopkinton, Massachusetts 283600RP002
1.0
INTRODUCTION
The Site Owner’s Manual complies with the Long-Term Pollution Prevention Plan (Standard 4) and the Long-Term Operation and Maintenance Plan (Standard 9) requirements of the 2008 Massachusetts Department of Environmental Protection (DEP) Stormwater Handbook. The Manual outlines source control and pollution prevention measures and maintenance requirements of stormwater best management practices (BMPs) associated with the proposed development.
Introduction
1-1
CEC Solar #1206, LLC Site Owner’s Manual Hopkinton, Massachusetts 283600RP002
2.0
SITE OWNER’S AGREEMENT
2.1
Operation and Maintenance Compliance Statement Site Owner:
Clean Energy Collective 146 West Boylston Street, 3rd Floor Worcester, MA 01606
Responsible Party:
Clean Energy Collective
Clean Energy Collective or their successors shall maintain ownership of the on-site stormwater management system as well as the responsibility for operation and maintenance during the post-development stages of the project. The site has been inspected for erosion and appropriate measures have been taken to permanently stabilize any eroded areas. All aspects of stormwater best management practices (BMPs) have been inspected for damage, wear and malfunction, and appropriate steps have been taken to repair or replace the system or portions of the system so that the stormwater at the site may be managed in accordance with the Stormwater Management Standards. Future responsible parties shall be notified of their continuing legal responsibility to operate and maintain the BMPs. The operation and maintenance plan for the stormwater BMPs is being implemented. ___________________________ Responsible Party Signature
___________ Date
2.2
Stormwater Maintenance Easements There are no off-site areas utilized for stormwater control, therefore no stormwater management easements are required. The Site Owner will have access to all stormwater practices for inspection and maintenance, including direct maintenance access by heavy equipment to structures requiring regular maintenance.
2.3
Record Keeping The Site Owner shall maintain a rolling log in which all inspections and maintenance activities for the past three years shall be recorded. The Operation and Maintenance Log includes information pertaining to inspections, repairs, and disposal relevant to the project’s stormwater management system. The Log is located in Appendix A. The Operation and Maintenance Log shall be made available to the Conservation Commission and the DEP upon request. The Conservation Commission and the DEP shall be allowed to enter and inspect the premises to evaluate and ensure that the responsible party complies with the maintenance requirements for each BMP.
Site Owner’s Agreement
2-1
CEC Solar #1206, LLC Site Owner’s Manual Hopkinton, Massachusetts 283600RP002
2.4
Training Employees involved in grounds maintenance and emergency response will be educated on the general concepts of stormwater management and groundwater protection. The Site Owner’s Manual will be reviewed with the maintenance staff. The staff will be trained on the proper course of action for specific events expected to be incurred during routine maintenance or emergency situations.
Site Owner’s Agreement
2-2
CEC Solar #1206, LLC Site Owner’s Manual Hopkinton, Massachusetts 283600RP002
3.0
LONG-TERM POLLUTION PREVENTION PLAN
In compliance with Standard 4 of the 2008 DEP Stormwater Management Handbook, this section outlines source control and pollution prevention measures to be employed on-site after construction. 3.1
Storage of Materials and Waste The site shall be kept clear of trash and debris at all times. Certain materials and waste products shall be stored inside or outside upon an impervious surface and covered, as required by local and state regulations.
3.2
Vehicle Washing No commercial vehicle washing shall take place on site.
3.3
Routine Inspections and Maintenance of Stormwater BMPs See Section 4.0 Long-Term Operation and Maintenance Plan, for routine inspection and maintenance requirements for all proposed stormwater BMPs.
3.4
Spill Prevention and Response A contingency plan shall be implemented to address the spill or release of petroleum products and hazardous materials and will include the following measures: 1. Equipment necessary to quickly attend to inadvertent spills or leaks shall be stored on-site in a secure but accessible location. Such equipment shall include but not be limited to the following: safety goggles, chemically resistant gloves and overshoe boots, water and chemical fire extinguishers, sand and shovels, suitable absorbent materials, storage containers and first aid equipment (i.e. Indian Valley Industries, Inc. 55-gallon Spill Containment kit or approved equivalent). 2. Spills or leaks shall be treated properly according to material type, volume of spillage and location of spill. Mitigation shall include preventing further spillage, containing the spilled material in the smallest practical area, removing spilled material in a safe and environmentally-friendly manner, and remediation of any damage to the environment. 3. For large spills, Massachusetts DEP Hazardous Waste Incident Response Group shall be notified immediately at (617) 792-7653 and an emergency response contractor shall be consulted.
3.5
Vegetation Maintenance Plan See attached Solar Facility’s Operation and Maintenance Plan (Appendix C). Vegetated stormwater BMPs will be maintained as outlined in Section 4.0.
Long-Term Pollution Prevention Plan
3-1
CEC Solar #1206, LLC Site Owner’s Manual Hopkinton, Massachusetts 283600RP002
3.6
Storage and Use of Fertilizers, Herbicides, and Pesticides Fertilizers, herbicides, and pesticides will not be used at the proposed facility.
3.7
Snow Removal Plan See attached Solar Facility’s Operation and Maintenance Plan.
3.8
Nutrient Management Plan A nutrient management plan is required if a Total Maximum Daily Load (TMDL) has been developed that indicates that use of fertilizers containing nutrients or other specific pollutants must be reduced. The proposed project is located within the Upper/Middle Charles River watershed, which has a final TMDL issued for Phosphorous. As indicated in Section 3.6, fertilizers, herbicides, and pesticides will not be used at the proposed facility. Runoff generated onsite will be routed to infiltration basins for peak flow mitigation and treatment.
Long-Term Pollution Prevention Plan
3-2
CEC Solar #1206, LLC Site Owner’s Manual Hopkinton, Massachusetts 283600RP002
4.0
LONG-TERM OPERATION AND MAINTENANCE PLAN
This section outlines the stormwater best management practices (BMPs) associated with the proposed stormwater management system and identifies the long-term inspection and maintenance requirements for each BMP. 4.1
4.2
Stormwater Management System Components The following table outlines the type and quantity of the BMPs and their general location. Please reference the site plan(s) provided in the Figures section for exact location. All basins are accessible for maintenance from within the array. BMP Type
Quantity
Location
Conveyance Swale
1
Along eastern perimeter, to Basin 1.
Infiltration Basin
3
Basin 1 (northeastern corner of Site), Basin 2 (center of Site), & Basin 3 (western perimeter of Site)
Inspection and Maintenance Schedules 4.2.1
Conveyance Swales Conveyance swales shall be inspected and maintained as outlined below: •
• •
•
Swales shall be inspected during the first three months after installation to ensure vegetation is adequate and slopes are not eroding. All eroded areas shall be repaired and revegetated. Thereafter, swales shall be inspected once per year. During the inspection, swales shall be checked for: o Slope integrity o Soil moisture o Vegetative health o Soil stability o Soil compaction o Soil erosion o Ponding o Sedimentation Corrective measures shall be taken immediately as warranted by the inspections. The swales shall be mowed at least once per year. The vegetation shall be maintained at a length of 3-6 inches to ensure the effectiveness of the vegetation in reducing flow velocity and removing pollutants. Clippings shall be removed after each mowing. Sediment and debris shall be removed manually at least once per year.
Long-Term Operation and Maintenance Plan
4-1
CEC Solar #1206, LLC Site Owner’s Manual Hopkinton, Massachusetts 283600RP002
• •
4.2.2
If any evidence of hydrocarbons is found during inspection, the material shall be immediately removed using absorbent pads or other suitable measures and legally disposed. The swales shall be reseeded as necessary to maintain a dense growth of vegetation.
Infiltration Basins Infiltration basins shall be inspected and maintained after major storm events (rainfall totals greater than 2.5 inches in 24 hours) during the first three months of operation and twice a year and when there are discharges through the outlet control structure thereafter. Additionally, all pretreatment BMPs shall be inspected in accordance with the minimal requirements specified for those practices and after all major storm events. Inspections shall include the following measures: •
• • • •
During and after major storm events, the length of time standing water remains in the basin shall be recorded. o If the time is greater than 72 hours, thoroughly inspect the basin for signs of clogging. o A corrective action plan shall be developed by a qualified professional to restore infiltrative function. The Site Owner shall take immediate action to implement these corrective measures. Examine the outlet structure for evidence of clogging or outflow release velocities that are greater than the design velocity. Identify areas of sediment accumulation, differential settlement, cracking, and erosion within the basin. Inspect embankments for leakage and tree growth. Examine the health of the vegetation within the basin and on the embankments.
Corrective measures shall be taken immediately as warranted by the inspections. If any evidence of hydrocarbons is found during inspection, the material shall be immediately removed using absorbent pads or other suitable measures and legally disposed. Preventative maintenance shall include the following activities: • Mow the buffer area and basin bottom and side slopes, if vegetated. • Remove trash, debris, and accumulated organic matter. • Remove clippings after mowing. 4.2.3
Stormwater Outfalls Flared end sections and associated riprap spillways shall be inspected at least once per year and after major storm events (rainfall totals greater than 2.5
Long-Term Operation and Maintenance Plan
4-2
CEC Solar #1206, LLC Site Owner’s Manual Hopkinton, Massachusetts 283600RP002
inches in 24 hours) to ensure that the stability of the outlet area is maintained. The outfall area shall be kept clear of debris such as trash, branches, and sediment. Repairs shall be made immediately if riprap displacement or downstream channel scour is observed. 4.3
Estimated Operation and Maintenance Budget An operations and maintenance budget was prepared to approximate the annual cost of the inspections required in compliance with the DEP Stormwater Management Policy. The table below estimates the annual cost to inspect and maintain each proposed BMP, based on the requirements in Section 4.2. BMP Type Water Quality Swale Infiltration Basin Riprap Spillway Stormwater Outfalls
4.4
# of BMPS 1 3 3 6
Annual O&M Cost (per BMP) 1 $400-$800 $200 - $400 $50-$100 $50-$100 Total
Total Cost $400-$800 $600-$1,200 $150-$300 $300-$600
Public Safety Features The facility contains a perimeter fence and gates that will be locked to prevent unauthorized entry into the facility.
1
Annual maintenance cost is based on estimate of the cost to complete all inspection and maintenance measures outlined in Section 4.2. For BMPs that require sediment removal at regular intervals (i.e. every 5 or 10 years), the annual cost includes the annual percentage of that cost.
Long-Term Operation and Maintenance Plan
4-3
Figures Figure 1: Site Plans
Appendices
Appendix A Operation and Maintenance Log
CEC Solar #1206, LLC Operation and Maintenance Log Hopkinton, Massachusetts 283600RP002
OPERATION AND MAINTENANCE LOG This template is intended to comply with the operation and maintenance log requirements of the 2008 DEP Stormwater Management Handbook. Copies of this log should be made for all inspections and kept on file for three years from the inspection date. Name/Company of Inspector: Date/Time of Inspection: Weather Conditions: (Note current weather and any recent precipitation events)
Stormwater BMP
Inspection Observations
Actions Required
Appendix B List of Emergency Contacts
Emergency Contacts Massachusetts DEP Hazardous Waste Incident Response Group (617)792-7653 Town of Hopkinton Department of Public Works 66 Fruit Street Hopkinton, MA 01748 (508)497-9740 Town of Hopkinton Fire Department 73 Main Street Hopkinton, MA 01748 (508)497-2323 Town of Hopkinton Police Department 74 Main Street Hopkinton, MA 01748 (508)497-3401
Appendix F Stormwater Pollution Prevention Plan
283600RP003
August 10, 2017
BEALS AND THOMAS, INC. Reservoir Corporate Center 144 Turnpike Road Southborough, MA 01772-2104
BEALS+THOMAS
Prepared by:
T F A R D
CEC Solar #1206, LLC c/o Clean Energy Collective 146 West Boylston Drive, 3rd Floor Worcester, MA 01606
Prepared for:
147 Lumber Street Hopkinton, Massachusetts
CEC Solar #1206, LLC
EPA Construction General Permit
SITE EVALUATION, ASSESSMENT AND PLANNING ............................................4
OPERATOR(S)/ SUBCONTRACTORS ................................................................................... 1 STORMWATER TEAM........................................................................................................ 2
CONTACT INFORMATION/RESPONSIBLE PARTIES ...........................................1
EROSION AND SEDIMENT CONTROL BMPS ........................................................15
ENDANGERED SPECIES CERTIFICATION.......................................................................... 12 HISTORIC PRESERVATION .............................................................................................. 12 SAFE DRINKING WATER ACT UNDERGROUND INJECTION CONTROL REQUIREMENTS.... 13 APPLICABLE STATE OR LOCAL PROGRAMS .................................................................... 14
COMPLIANCE WITH APPLICABLE FEDERAL & STATE REQUIREMENTS 12
Table of Contents
i
4.1 NATURAL BUFFERS OR EQUIVALENT SEDIMENT CONTROLS .......................................... 15 4.2 MINIMIZE DISTURBED AREA AND PROTECT NATURAL FEATURES AND SOIL ................. 17 4.2.1 Preserve Existing Vegetation .................................................................................... 17 4.2.2 Stockpiling Topsoil.................................................................................................... 17 4.3 PHASED CONSTRUCTION ACTIVITY................................................................................ 17 4.3.1 Phase I ...................................................................................................................... 17
4.0
3.1 3.2 3.3 3.4
3.0
T F A R D
2.1 PROJECT/SITE INFORMATION ........................................................................................... 4 2.1.1 Emergency-Related Projects ....................................................................................... 5 2.2 NATURE AND SEQUENCE OF CONSTRUCTION ACTIVITY ................................................... 5 2.2.1 Function of the Construction Activity ......................................................................... 5 2.2.2 Building Demolition .................................................................................................... 5 2.2.3 Agricultural Land........................................................................................................ 5 2.2.4 Estimated Project Dates ............................................................................................. 5 2.3 SOILS, SLOPES, VEGETATION, AND CURRENT DRAINAGE PATTERNS ............................... 7 2.4 CONSTRUCTION SITE ESTIMATES ..................................................................................... 7 2.5 DISCHARGE INFORMATION............................................................................................... 8 2.5.1 Description of Receiving Storm Sewer Systems .......................................................... 8 2.5.2 Receiving Waters ........................................................................................................ 8 2.5.3 Impaired Waters/ TMDLs ........................................................................................... 8 2.5.4 Tier 2, 2.5, or 3 Waters ............................................................................................... 9 2.6 UNIQUE SITE FEATURES AND SENSITIVE AREAS .............................................................. 9 2.7 CONSTRUCTION SUPPORT ACTIVITIES.............................................................................. 9 2.7.1 Support Activity Site Information................................................................................ 9 2.7.2 Support Activity Contact Information ......................................................................... 9 2.8 POTENTIAL SOURCES OF POLLUTION ............................................................................... 9 2.8.1 Potential Sources of Sediment .................................................................................... 9 2.8.2 Potential Sources of Non-Sediment Pollutants ........................................................... 9 2.9 SITE PLANS .................................................................................................................... 11
2.0
1.1 1.2
1.0
TABLE OF CONTENTS
283600RP003
CEC Solar #1206, LLC Stormwater Pollution Prevention Plan (SWPPP) Hopkinton, Massachusetts
GOOD HOUSEKEEPING BMPS ..................................................................................23
6.0
Table of Contents
ii
POST-CONSTRUCTION BMPS ...................................................................................31
5.1 MATERIAL HANDLING AND WASTE MANAGEMENT ....................................................... 23 5.1.1 Solid or Construction Waste Disposal ...................................................................... 24 5.1.2 Recycling ................................................................................................................... 24 5.1.3 Sanitary and Septic Waste ........................................................................................ 25 5.1.4 Hazardous Materials and Waste............................................................................... 25 5.2 ESTABLISH PROPER BUILDING MATERIAL STAGING AREAS .......................................... 26 5.3 DESIGNATE WASHOUT AREAS ....................................................................................... 26 5.3.1 Concrete Washout ..................................................................................................... 26 5.3.2 Applicators, Containers and Paint Washout ............................................................ 27 5.4 ESTABLISH PROPER EQUIPMENT/VEHICLE FUELING AND MAINTENANCE PRACTICES ... 28 5.5 ALLOWABLE NON-STORMWATER DISCHARGES AND CONTROL EQUIPMENT / VEHICLE WASHING ................................................................................................................................... 28 5.6 SPILL PREVENTION AND CONTROL PROCEDURES ........................................................... 29 5.7 FERTILIZER DISCHARGE RESTRICTIONS ......................................................................... 29 5.8 ANY ADDITIONAL BMPS ............................................................................................... 30 5.9 ALLOWABLE NON-STORMWATER DISCHARGE MANAGEMENT ...................................... 30
5.0
T F A R D
INSPECTIONS AND MAINTENANCE .......................................................................34
PERMANENT SEEDING .................................................................................................... 32
FINAL STABILIZATION ..............................................................................................32
DETENTION BASIN ......................................................................................................... 31 INFILTRATION BASIN ..................................................................................................... 31 BIORETENTION AREA ..................................................................................................... 31 GRASS DRAINAGE CHANNELS........................................................................................ 31 INFILTRATION TRENCH .................................................................................................. 31 POROUS PAVERS ............................................................................................................ 31 TREE BOX FILTER .......................................................................................................... 31 DEEP SUMP AND HOODED CATCH BASINS AND WATER QUALITY STRUCTURES............ 31
T F A R D
RECORDKEEPING AND TRAINING .........................................................................36
10.1 10.2 10.3 10.4
10.0
Table of Contents
iii
SIGNATURE, PLAN REVIEW, AND MAKING PLANS AVAILABLE ...................................... 38 NOTICE OF PERMIT COVERAGE ........................................................................................ 38 OWNER CERTIFICATION ................................................................................................. 39 OPERATOR CERTIFICATION ............................................................................................ 40
CERTIFICATION AND NOTIFICATION ..................................................................38
9.1 RECORDKEEPING............................................................................................................ 36 9.2 LOG OF CHANGES TO THE SWPPP ................................................................................. 36 9.3 TRAINING ....................................................................................................................... 36 9.3.1 Individual(s) Responsible for Training ..................................................................... 36 9.3.2 Description of Training Conducted .......................................................................... 37
9.0
8.1 INSPECTIONS .................................................................................................................. 34 8.1.1 Inspection Schedule and Procedures ........................................................................ 34 8.2 REDUCTIONS IN INSPECTION FREQUENCY ...................................................................... 35 8.3 CORRECTIVE ACTION LOG ............................................................................................. 35
8.0
7.1
7.0
6.1 6.2 6.3 6.4 6.5 6.6 6.7 6.8
283600RP003
283600RP003
4.3.2 Phase II ..................................................................................................................... 17 4.4 CONTROL STORMWATER FLOWING ONTO AND THROUGH THE PROJECT........................ 17 4.4.1 Earth Dike ................................................................................................................. 17 4.4.2 Grass Drainage Channels......................................................................................... 17 4.5 STABILIZE SOIL .............................................................................................................. 18 4.5.1 Temporary Stabilization............................................................................................ 18 4.5.2 Mulching ................................................................................................................... 18 4.5.3 Permanent Stabilization ............................................................................................ 19 4.5.4 Dust Control ............................................................................................................. 19 4.6 PROTECT SLOPES ........................................................................................................... 19 4.6.1 Erosion Control Blanket ........................................................................................... 19 4.7 PROTECT STORM DRAIN INLETS .................................................................................... 19 4.7.1 Filter Bags ................................................................................................................ 19 4.8 ESTABLISH PERIMETER CONTROLS AND SEDIMENT BARRIERS ...................................... 20 4.8.1 Erosion Control Barrier ........................................................................................... 20 4.8.2 Silt Fence .................................................................................................................. 20 4.9 PREVENT SOIL COMPACTION ......................................................................................... 21 4.9.1 Protect Proposed Infiltration Areas.......................................................................... 21 4.10 RETAIN SEDIMENT ON-SITE ........................................................................................... 21 4.10.1 Temporary Sediment Basins ................................................................................. 21 4.11 ESTABLISH STABILIZED CONSTRUCTION ENTRANCE/EXIT............................................. 22 4.12 DEWATERING PRACTICES .............................................................................................. 22 4.13 ADDITIONAL BMPS ....................................................................................................... 23 4.13.1 BMP Name ............................................................................................................ 23
CEC Solar #1206, LLC Stormwater Pollution Prevention Plan (SWPPP) Hopkinton, Massachusetts
CEC Solar #1206, LLC Stormwater Pollution Prevention Plan (SWPPP) Hopkinton, Massachusetts
CONSTRUCTION GENERAL PERMIT
NOI AND ACKNOWLEDGEMENT LETTER FROM EPA
INSPECTION REPORTS
CORRECTIVE ACTION LOG
SWPPP AMENDMENT LOG
SUBCONTRACTOR CERTIFICATIONS/ AGREEMENTS
GRADING AND STABILIZATION ACTIVITIES LOG
TRAINING LOG
DELEGATION OF AUTHORITY
ENDANGARD SPECIES DOCUMENTATION
HISTORIC PRESERVATION DOCUMENTATION
TEMPORARY SEDIMENT BASIN SIZING CALCULATION
NATURAL BUFFER EQUIVALENCY CALCULATIONS
APPENDIX C:
APPENDIX D:
APPENDIX E:
APPENDIX F:
APPENDIX G:
APPENDIX H:
APPENDIX I:
APPENDIX J:
APPENDIX K:
APPENDIX L:
APPENDIX M:
APPENDIX N:
APPENDIX O:
Table of Contents
SITE PLANS
APPENDIX B:
T F A R D
GENERAL LOCATION MAP
APPENDIX A:
LIST OF APPENDICES
iv
283600RP003
CEC Solar #1206, LLC Stormwater Pollution Prevention Plan (SWPPP) Hopkinton, Massachusetts
Company:
Worcester
146 West Boylston Drive
TBD
MA
City:
TBD ZIP Code:
TBD
Name:
Telephone: TBD
TBD
Company:
24-Hour Emergency Contact
TBD
TBD
01606
Contact Information/Responsible Parties
Site Work Contractor
State:
Area of Control:
City:
Email: TBD
TBD
Address:
Email: TBD
TBD ZIP Code:
ZIP Code:
Telephone: TBD
TBD
TBD
Name:
Subcontractor Name
Company:
Subcontractor(s)
Telephone: TBD
TBD
TBD
Address:
State:
Email: TBD
State:
T F A R D TBD
Contractor Name
Name:
Company:
Telephone: TBD
City:
Address:
Name:
Clean Energy Collective
OPERATOR(S)/ SUBCONTRACTORS
1.1 Operator(s)
CONTACT INFORMATION/RESPONSIBLE PARTIES
1.0
1
1.2
Southborough
Address:
City:
MA
ZIP Code:
01772
Email: [email protected]
State:
TBD
TBD
TBD
City:
Telephone:
TBD
TBD
TBD
Company:
Name:
Address:
Inspection Personnel
TBD ZIP Code:
TBD
TBD
Contact Information/Responsible Parties
Email: TBD
State:
Email: TBD
TBD ZIP Code:
Telephone:
Address: State:
TBD
City:
TBD
TBD
Name:
TBD
Company:
T F A R D
2
Personnel Responsible for Installation & Maintenance of Stormwater BMPs
Telephone: 508-366-0560
Christopher Hale-Sills
144 Turnpike Road
Name:
Beals and Thomas, Inc.
Company:
SWPPP Preparer
STORMWATER TEAM
TBD TBD
Address: City: Telephone:
TBD ZIP Code: Email: TBD
State:
TBD
Contact Information/Responsible Parties
T F A R D
TBD TBD
Name:
TBD
Company:
Personnel Responsible for Taking Corrective Actions
3
Longitude:
-71.5308°
ZIP Code:
WGS 84 Unknown
01606
Yes
No
Site Evaluation, Assessment and Planning
NPDES project or permit tracking number: TBD
4
Are you applying for permit coverage as a “federal operator” as defined in Appendix A of the 2012 CGP? Yes No
Is this project considered a federal facility?
______________________________________________________
If yes, provide the name of the Indian tribe associated with the area of Indian country (including the name of Indian reservation if applicable), or if not in Indian country, provide the name of the Indian tribe associated with the property:
Is the project located on Indian country lands, or located on a property of religious of Yes No cultural significance to an Indian tribe?
Horizontal Reference Datum: NAD 27 NAD 83
T F A R D
Method for Determining Latitude/Longitude: USGS Topographic Map (specify scale: _________) EPA Website GPS Other (please specify): _Google Earth_______
42.2009°
Latitude:
MA
Middlesex
State:
County or Similar Subdivision:
Hopkinton
147 Lumber Street
Project Street/Location:
City:
CEC Solar #1206, LLC
PROJECT/SITE INFORMATION
2.1
Project/Site Name:
SITE EVALUATION, ASSESSMENT AND PLANNING
2.0
2.2
Yes
No
T F A R D
Yes
No
Site Evaluation, Assessment and Planning
Estimated Project Start Date: TBD Estimated Project Completion Date: TBD
2.2.4 Estimated Project Dates
2.2.3 Agricultural Land Was the pre-development land used for agriculture?
If yes, do any of the structures being demolished have at least 10,000 square feet Yes No of floor space?
2.2.2 Building Demolition Will there be demolition of any structure built or renovated before January 1, 1980? Yes No
Highway or Road Construction Other (please specify):_Solar Energy__
Institutional
Industrial
Multi-Family Residential
Utility
Commercial
Single-Family Residential
Function of the construction activity:
The project consists of the construction of a 6 MW solar energy facility within existing agricultural fields as well as in currently wooded areas.
2.2.1 Function of the Construction Activity
NATURE AND SEQUENCE OF CONSTRUCTION ACTIVITY
5
If yes, document the cause of the public emergency (e.g., natural disaster, extreme flooding conditions), information substantiating its occurrence (e.g., state disaster declaration), and a description of the construction necessary to reestablish effective public services:
Is this project in response to a public emergency?
2.1.1 Emergency-Related Projects
Construction Activity and BMP Descriptions
Before any site grading activities begin 1. Stake Limit of Construction. Workers shall be informed that no construction activity is to occur beyond this limit at any time. 2. Delineate the limit of the natural buffer to be maintained with flags, tape or other similar device. 3. Clear vegetation as necessary within the limits of construction. A stockpile of wood chips from tree cutting shall be left on site for stabilization. 4. Grub the areas where silt fence is required, removing stumps and roots as necessary. The existing ground surface shall be disturbed as little as possible prior to the start of construction. 5. Install silt fence and straw bales as shown on the plans. An adequate stockpile of erosion control materials shall be on site at all times for emergency or routine replacement and shall include materials to repair silt fences, straw bales, or any other devices planned for use during construction. 6. Construct stabilized construction exits. 7. Construct staging and materials storage area. 8. Install temporary sanitary facilities and dumpsters.
Date Start –Date End
Date Start –Date End
Site Evaluation, Assessment and Planning
6
Site grading 1. Begin site clearing and grubbing operations. 2. Commence excavation of stormwater management basins to act as temporary sedimentation basins during construction. 3. Commence construction of temporary drainage channels to direct runoff to sedimentation basin(s) during construction. Check dams shall be installed along the temporary drainage channels to reduce velocities and collect sediment. 4. Begin overall site grading and topsoil stripping. 5. Establish topsoil stockpile. 6. Install silt fences around stockpile and cover stockpiles. 7. Disturbed areas where construction will cease for more than 14 days shall be stabilized with erosion controls. Array Construction 1. Begin construction of Array. 2. Implement winter stabilization procedures.
T F A R D
Estimated Timeline of Activity Date Start –Date End
2.4
2.3
Final stabilization and landscaping 1. Convert temporary sediment basin(s) to (a) permanent infiltration basins. 2. Remove all temporary control BMPs and stabilize any areas disturbed by their removal with erosion controls 3. Prepare final seeding and landscaping. 4. Monitor stabilized areas until final stabilization is reached.
Total property area:
CONSTRUCTION SITE ESTIMATES
Site Evaluation, Assessment and Planning
TBD acres 7
Vegetation: The solar array is proposed within an area that is comprised of predominantly woodland vegetation. There is a portion of the property that is partially developed, and occupied by a single-family residence.
Drainage Patterns: The array is approximately centered on a high-point. Runoff from the site drains to the east and to the west. There are onsite bordering vegetated wetlands (BVW) at the eastern perimeter of the site as well as a potential vernal pool (PVP) and associated isolated vegetated wetland (IVW) at the southeastern quadrant. There is also a BVW at the western perimeter of the site (adjacent to Lumber Street). The resource areas at northeastern and western portions of the site ultimately flow to the north. The southeastern potion of the site (including the PVP and IVW) flows to the east and south.
Slopes: Slopes on site vary from 0% to 15%
T F A R D
Canton Fine Sandy Loam is a very deep, well drained soil on glaciated uplands. The typical soil profile is comprised of layers of fine sandy loam over gravelly fine sandy loam, over gravelly loamy sand. NRCS classifies these soils as Hydrologic Soil Group (HSG) “A” (extremely bouldery) & “B” (extremely stony). Narragansett Silt Loam, is a deep, well drained soil on glacial till plains and ground moraine. The typical soil profile is comprised of layers of silt loam over very gravelly loamy sand. NRCS classifies this soil as HSG “A”. Ridgebury Fine Sandy Loam, a very deep, poorly drained to somewhat poorly drained soil on glacial till uplands. The typical soil profile is comprised of layers of fine sandy loam over loamy fine sand, sand, and gravelly coarse sand. NRCS classifies this soil as HSG “D”.
Soil type(s): The Natural Resources Conservation Service (NRCS) Web Soil Survey lists the on-site soils as Canton Fine Sandy Loam, Narragansett Silt Loam, and some areas of Ridgebury Fine Sandy Loam.
SOILS, SLOPES, VEGETATION, AND CURRENT DRAINAGE PATTERNS
Date Start –Date End
2.5
TBD acres TBD % TBD TBD % TBD
Maximum area to be disturbed at one time:
Percentage impervious area before construction:
Runoff coefficient before construction:
Percentage impervious area after construction:
Runoff coefficient after construction:
2.8
Does your project/site discharge stormwater into a Municipal Separate Storm Sewer System (MS4)? Yes No
Yes
No
Yes
No
Site Evaluation, Assessment and Planning
List the pollutant(s) for which there is a TMDL: Phosphorus
8
If yes, list the title of the TMDL document: Total Maximum Daily Load for Nutrients in the Upper/Middle Charles River, Massachusetts
Has a TMDL been completed?
Describe the method(s) used to determine whether or not your project site discharges to an impaired water: Mass GIS Oliver mapping.
If yes, list the pollutant(s) causing the impairment: Phosphorus
Has the surface water been listed as “impaired?”
2.5.3 Impaired Waters/ TMDLs
Portions of the site drain to Echo Lake, which is a tier 2.5, or public water supply, which feeds the Charles River. Other portions of the site drain to Icehouse Pond, then Indian Brook, which feeds the Hopkinton Reservoir. A third portion of the site drains to Wildcat Pond, and then the Charles River.
2.5.2 Receiving Waters
2.7
2.6
2.5.1 Description of Receiving Storm Sewer Systems
T F A R D
DISCHARGE INFORMATION
TBD acres
Total construction site area to be disturbed:
Tier 2.5
Yes
Tier 3
No
T F A R D
Clearing and grubbing operations Grading and site excavation operations Vehicle tracking Topsoil stripping and stockpiling Landscaping operations
[2]
Fertilizer
Pesticides
Material/ Chemical
x
x
x
x
Chlorinated hydrocarbons, organophosphates, carbamates, arsenic Nitrogen, phosphorous
Various colored to colorless liquid, powder, pellets, or grains Liquid or solid grains
9
Herbicides used for noxious weed control Newly seeded areas
Location[1]
Site Evaluation, Assessment and Planning
Stormwater Pollutants
Physical Description
Combined Staging Area — small fueling activities, minor equipment maintenance, sanitary facilities, and hazardous waste storage. Materials Storage Area — general building materials, solvents, adhesives, paving materials, paints, aggregates, trash, and so on. Construction Activity — paving, curb/gutter installation, concrete pouring/mortar/stucco, and building construction Concrete Washout Area
2.8.2 Potential Sources of Non-Sediment Pollutants
x x x x x
2.8.1 Potential Sources of Sediment
POTENTIAL SOURCES OF POLLUTION
CONSTRUCTION SUPPORT ACTIVITIES Construction support activities are not required for the project.
There are onsite bordering vegetated wetlands (BVW) at the eastern perimeter of the site as well as a potential vernal pool (PVP) and associated isolated vegetated wetland (IVW) at the southeastern quadrant. There is also a BVW at the western perimeter of the site (adjacent to Lumber Street). The resource areas at northeastern and western portions of the site appear to ultimately flow to the north.
UNIQUE SITE FEATURES AND SENSITIVE AREAS
If yes specify which Tier the surface water is designated as: Tier 2
Is this surface water designated as a Tier 2, 2.5 or 3 water?
2.5.4 Tier 2, 2.5, or 3 Waters
Stoddard solvent, petroleum distillates, arsenic, copper, chromium
Naphtha
Metal oxides, stoddard solvent, talc, calcium carbonate, arsenic
Polymers, epoxies
Oil, petroleum distillates
Perchloroethylene, methylene chloride, trichloroethylene, petroleum distillates
Benzene, ethyl benzene, toluene, xylene, MTBE
Petroleum distillate, oil & grease, naphthalene, xylenes
Coal oil, petroleum distillates
Colorless, pale brown or pink petroleum hydrocarbon
Clear, blue-green to yellow liquid
Pale yellow liquid petroleum hydrocarbon
Gasoline
Diesel Fuel
Kerosene
Curb and gutter, walkways Timber pads and building construction Leaks or broken hoses from equipment Secondary containment/staging area Secondary containment/staging area Secondary containment/staging area Leaks or broken hoses from equipment
Building construction
Streets, parking areas, and roofing Building construction
No equipment cleaning allowed in project limits
Antifreeze/ coolant
Clear green/yellow liquid
Site Evaluation, Assessment and Planning
10
Ethylene glycol, propylene glycol, heavy metals (copper, lead, zinc) Sanitary Bacteria, parasites, and Various colored liquid Staging area toilets viruses [1] Area where material/chemical is used on-site. [2] Use of fertilizers containing nitrogen and/ or phosphorus in ratios greater than recommended by the manufacture must be documented.
Mineral oil
Brown oily petroleum hydrocarbon
Hydraulic oil/fluids
T F A R D
Clear amber or dark brown liquid
Various colored liquids
Paints
Wood preservatives
White or yellow liquid
Glue/ adhesives
Creamy white liquid
Black solid
Asphalt
Curing compounds
Colorless, blue, or yellow-green liquid
Cleaning solvents
2.9
T F A R D
See Appendix B: Site Plans
Site Evaluation, Assessment and Planning
Areas of federally-listed critical habitat for endangered or threatened species
11
Locations where polymers, flocculants, or other treatment chemicals will be used and stored
Locations of all pollutant-generating activities
Locations of storm drain inlets and stormwater control measures on the site and in the immediate vicinity of the site
Locations where stormwater discharges or allowable non-stormwater to surface water(s)
Boundary lines of any natural buffers,
Location of all waters of the U.S., including wetlands on or near the site. Indicate if water bodies are listed as impaired, or are identified as Tier 2, 2.5 or 3 waters.
Locations of off-site material, waste, borrow, or equipment storage areas
Locations [and timing] of stabilization measures
Location(s) of sediment, soil or other construction materials will be stockpiled
Locations of major structural and non-structural BMPs identified in the SWPPP
Natural features to be preserved
Direction(s) of stormwater flow and approximate slopes before and after major grading activities
Areas of soil disturbance and areas that will not be disturbed
Delineation of construction phasing, if applicable
These Site Plans include:
The Topographic Plan shows the undeveloped site and its current features. The Site Plans show the developed site.
SITE PLANS
3.2
ENDANGERED SPECIES CERTIFICATION
3.1
Compliance with Applicable Federal & State Requirements
If yes, provide documentation of the basis for your determination.
12
Step 3 If you answered no in Step 2, has it been determined that the installation of subsurface earth-disturbing stormwater controls will have no effect on historic properties? Yes No
Step 2 If you answered yes in Step 1, have prior surveys or evaluations conducted on the site already determined that historic properties do not exist, or that prior disturbances at the site have precluded the existence of historic properties? Yes No
Step 1 Will stormwater controls that require subsurface earth disturbance be installed on the site? Yes No
HISTORIC PRESERVATION
If yes, describe or refer to documentation that determines the likelihood of an impact on the identified species and/or habitat and the steps taken to address that impact.
If yes, describe the species and/or critical habitat:
T F A R D
Additionally, the NHESP Northern Long-eared Bat Locations in Massachusetts map, last updated March 24, 2016 was reviewed and it was determined that the Project does not occur within 0.25 miles of a known winter hibernacula or within a 150-foot radius of a known maternity roost tree. Therefore, no further review of potential impacts to Northern Long-eared Bat is required pursuant to the MESA.
Describe how this determination was made: The MASSGIS NHESP Priority Habitat of Rare Species Layer, Updated September, 2008, indicates that no priority habitat of rare species are located within the project site.
Are endangered or threatened species and critical habitats on or near the project area? Yes No
COMPLIANCE WITH APPLICABLE FEDERAL & STATE REQUIREMENTS
3.0
3.3
T F A R D
Compliance with Applicable Federal & State Requirements
13
If yes, attach documentation of contact between you and the applicable state agency or EPA Regional Office responsible for implementing the requirements for underground injection wells in the Safe Drinking Water Act and EPA’s implementing regulations at 40 CFR Parts 144-147.
Drywells, seepage pits, or improved sinkholes (if stormwater is directed to any bored, drilled, driven shaft or dug hole that is deeper than its widest surface dimension, or has a subsurface fluid distribution system)
Commercially manufactured pre-cast or pre-built proprietary subsurface detention vaults, chambers, or other devices designed to capture and infiltrate stormwater flow
Infiltration trenches (if stormwater is directed to any bored, drilled, driven shaft or dug hole that is deeper than its widest surface dimension, or has a subsurface fluid distribution system)
Do you plan to install any of the following controls?
SAFE DRINKING WATER ACT UNDERGROUND INJECTION CONTROL REQUIREMENTS
Other:
No agreement has been reached regarding measures to mitigate effects to historic properties from the installation of stormwater controls.
Written indication that adverse effects to historic properties from the installation of stormwater controls can be mitigated by agreed upon actions.
If no, no further documentation is required. If yes, describe the nature of their response and include documentation in the Appendix:
Step 4 If you answered no in Step 3, did the State Historic Preservation Officer (SHPO), Tribal Historic Preservation Office (THPO), or other tribal representative (whichever applies) respond within 15 calendar days to indicate whether the subsurface earth disturbances caused by the installation of stormwater controls affect historic properties? Yes No
3.4
Compliance with Applicable Federal & State Requirements
T F A R D
14
A plan to control construction-related impacts, including erosion, sedimentation, and other pollutant sources during construction and land disturbance activities (construction period erosion, sedimentation, and pollution prevention plans) shall be developed and implemented.
NATURAL BUFFERS OR EQUIVALENT SEDIMENT CONTROLS
Natural Buffers or Equivalent Sediment Controls Minimize disturbed area and protect natural features and soil Control stormwater flowing onto and through the project Stabilize soils Protect slopes Establish perimeter controls and sediment barriers Retain sediment on-site and control dewatering practices Establish stabilized construction exits
Good Housekeeping BMPs
15
It is infeasible to provide and maintain an undisturbed natural buffer of any size, therefore erosion and sediment controls will be implemented that achieve the sediment load reduction equivalent to a 50-foot undisturbed natural buffer. The estimated
Description of Controls: Provide a description of the additional erosion and sediment controls proposed, including the model or other tool used to estimate the sediment load reductions and the results from the calculation.
An undisturbed natural buffer of xx-feet will be provided along with supplemental erosion and sediment controls, which in combination achieves the sediment load reduction equivalent to a 50-foot undisturbed natural buffer. The estimated sediment removal calculations are included in the appendixes of this report and have been calculated using the applicable tables included in Appendix G of the 2012 Construction General Permit or site-specific calculations were performed to estimate the sediment removal of a 50-buffer zone and the efficiency of the reduced buffer zone and supplemental erosion control measures.
A 50-foot undisturbed natural buffer will be maintained. The 50-foot buffer is shown on the attached site plans and will be clearly marked off with flags, tape, or a similar marking device prior to the commencement of earth disturbing activities.
If yes, check the compliance alternative that applies:
Are there any surface waters located within 50 feet of your construction disturbances that receive stormwater discharges from the site? Yes No
4.1
x x x x x x x x
This SWPPP contains a listing of the erosion and sediment control best management practices (BMPs) that will be implemented to control pollutants in stormwater discharges. The BMPs are categorized under one of the areas of BMP activity as described below:
This SWPPP complies with the requirements of Standard 8 of the Massachusetts Department of Environmental Protection Stormwater Handbook, which states:
EROSION AND SEDIMENT CONTROL BMPS
4.0
APPLICABLE STATE OR LOCAL PROGRAMS
Good Housekeeping BMPs
16
Buffer disturbances will occur for the construction of a water-dependent structure or water access area (e.g., pier, boat ramp, and trail).
Buffer disturbances are authorized under a CWA Section 404 permit.
Alternative 2: A sediment discharge risk evaluation has been prepared and is included in the appendices of this report.
Alternative 1: A [select one: 50-foot buffer, a buffer <50 feet and > 30 has been provided with double perimeter controls buffer less than 30-feet has been provided with double perimeter controls with 7-day site stabilization requirements has been provided.] Provide a description on how the controls will comply with the CGP requirements.
The project qualifies as “small residential lot” construction, and complies with:
For a “linear project,” site constraints (e.g., limited right-of-way) make it infeasible for the site to meet any of the CGP Part 2.1.2.1.a compliance alternatives
No natural buffer exists due to preexisting development disturbances, such as impervious surfaces or structures that were constructed prior to the initiation of planning for this project.
There is no discharge of stormwater to surface waters through the area between the disturbed portions of the site and any surface waters located within 50 feet of the site. This includes situations where control measures have been implemented such as a berm or other barrier that will prevent such discharges.
T F A R D
The project qualifies for one of the exceptions in Part 2.1.2.1.e. of the 2012 Construction General Permit. Specifically:
Description: Include rationale for why a natural buffer cannot be maintained. Provide a description of the additional erosion and sediment controls proposed, including the model or other tool used to estimate the sediment load reductions and the results from the calculation. Include the estimated sediment removal rate from a natural 50-buffer and the proposed controls.
sediment removal calculations are included in the appendixes of this report and have been calculated using the applicable tables included in Appendix G of the 2012 Construction General Permit or site-specific calculations were performed to estimate the sediment removal of a 50-buffer zone and the efficiency of the reduced buffer zone and supplemental erosion control measures.
4.3
4.2
Design Specifications
Maintenance and Inspection:
Installation Schedule:
Description:
Good Housekeeping BMPs
17
A grass drainage channel shall be installed at location, as indicated on the site plans. The channel shall convey runoff to storm drain inlets and temporary sediment basins, as appropriate or at locations shown on plans. Some grass drainage channels shall remain as a permanent stormwater structure after construction is complete. The grass drainage channel shall be installed after clearing and grubbing operations are completed at the site. The channel shall be inspected weekly and immediately after storm events for erosion and structural failures. Before vegetation has been established in the channel, inspect erosion control blankets, embankments, and beds for erosion and accumulation of debris and sediment. Remove debris, sediment, and repair erosion control blankets, fiber rolls and embankments immediately.
4.3.1 Grass Drainage Channels
CONTROL STORMWATER FLOWING ONTO AND THROUGH THE PROJECT
Topsoil stripped from the immediate construction area shall be stockpiled as identified on the Site Plans and Sitework Specifications or as approved by the SWPPP preparer. Stockpiles shall be located outside of any natural buffers and away from any stormwater conveyances, drain inlets, and areas where stormwater flow is concentrated. Installation Topsoil stockpiles shall be established during grading activities. Schedule: The silt fence and temporary erosion controls shall be installed immediately after the stockpile has been established. For piles that will be unused for 14 or more days provide cover over the stockpile or temporary stabilization to avoid direct contract with precipitation and wind. Install a sediment barrier along all downgradient perimeter areas of stockpiles. Maintenance The area shall be inspected weekly for erosion and immediately after and storm events. Areas on or around the stockpile that have eroded shall Inspection: be stabilized immediately with erosion controls. See following Silt Fence section for Maintenance and inspection procedures.
Description:
4.2.1 Stockpiling Topsoil
MINIMIZE DISTURBED AREA AND PROTECT NATURAL FEATURES AND SOIL
4.4
Initiation of temporary vegetative cover shall occur immediately where construction will cease for more that 7 days. It shall be established using hydroseeding for areas of exposed soil (including stockpiles). Temporary stabilization measures shall be initiated immediately where construction activities will temporarily cease for more than 14 days. Stabilized areas shall be inspected weekly and after storm events until a dense cover of vegetation has become established. If failure is noticed at the seeded area, the area shall be reseeded, fertilized, and mulched immediately.
Maintenance and Inspection:
Good Housekeeping BMPs
18
Hydromulching shall provide immediate protection to exposed soils during short periods of disturbance. Hydromulch shall also be applied in areas that have been seeded for temporary or permanent stabilization. Hydromulch shall be applied to exposed soils during short periods of construction and seeded areas. Mulched areas shall be inspected weekly and after storm events to check for movement of mulch or erosion. If washout, breakage, or erosion occurs, the surface shall be repaired, and new mulch shall be applied to the damaged area.
T F A R D
Installation Schedule:
Description:
4.4.2 Mulching
Maintenance and Inspection:
Installation Schedule:
Description:
4.4.1 Temporary Stabilization
STABILIZE SOIL
1. The channel shall have a positive drainage to convey runoff to the storm drain inlets and temporary sediment basins.
Maintenance and Inspection:
Installation Schedule:
Description:
4.4.4 Dust Control
Initiation of permanent stabilization measures shall occur immediately after the final design grades are achieved and earth moving activities cease. Native species of plants shall be used to establish vegetative cover on exposed soils. Permanent stabilization shall be completed in accordance with the procedures outlined in the Final Stabilization section of this report. Portions of the site where construction activities have permanently ceased shall be stabilized, as soon as possible. All seeded areas shall be inspected weekly during construction activities and after storm events until a dense cover of vegetation has been established. If failure is noticed at the seeded area, the area shall be reseeded, fertilized, and mulched immediately. Care shall be taken to avoid compacting newly placed topsoil. After construction is completed at the site, permanently stabilized areas shall be monitored until final stabilization is reached.
Good Housekeeping BMPs
19
Dust from the site shall be controlled by using a mobile pressure-type distributor truck to apply water to disturbed areas. The mobile unit shall apply water at a rate of 300 gallons per acre and minimized as necessary to prevent runoff and ponding. Dust control shall be implemented as needed once site grading has been initiated and during windy conditions (forecasted or actual wind conditions of 20 mph or greater) while site grading is occurring. Spraying of water shall be performed no more than three times a day during the months of May–September and once per day during the months of October–April or whenever the dryness of the soil warrants it. At least one mobile unit shall be available at all times to distribute water to control dust on the project area. Each mobile unit shall be equipped with a positive shutoff valve to prevent over watering of the disturbed area.
T F A R D
Maintenance and Inspection:
Installation Schedule:
Description:
4.4.3 Permanent Stabilization
4.5
Good Housekeeping BMPs
20
Temporary Entrenched silt fence shall be installed to decrease the velocity of sheet flows and intercept and detain small amounts of sediment from disturbed areas. Installation Schedule: Silt fence shall be installed prior to clearing and grubbing. Maintenance and Silt fence shall be inspected weekly, following storms, and Inspection: daily during rainy periods. Damaged fencing shall be replaced. Concentrated flows shall be intercepted and rerouted. Sediment accumulations shall be removed when reaching a depth of 6-inches. Deteriorated fencing material shall be replaced. Used fencing shall be properly disposed of.
Permanent Description:
4.5.2 Silt Fence
T F A R D
Temporary An erosion control barrier, consisting of entrenched straw bales, straw wattles, compost socks and siltation fencing, shall be installed along the downgradient side of the proposed project to decrease the velocity of sheet flows and intercept and detain small amounts of sediment from disturbed areas. Installation Schedule: Erosion Control Barrier shall be installed prior to clearing and grubbing. Maintenance and Erosion Control Barrier shall be inspected weekly, Inspection: following storms, and daily during rainy periods. Damaged fencing shall be replaced. Concentrated flows shall be intercepted and rerouted. Sediment accumulations shall be removed when reaching a depth of 6-inches, or one-half of the above ground height of the barrier, whichever is less. Deteriorated fencing material shall be replaced. Used fencing shall be properly disposed of.
Permanent Description:
4.5.1 Erosion Control Barrier
ESTABLISH PERIMETER CONTROLS AND SEDIMENT BARRIERS
4.7
4.6
Good Housekeeping BMPs
21
Temporary Temporary sediment basins are located throughout the site between construction and wetland resource areas. These basins provide 3,600 cubic feet of storage per acre drained, as required by the EPA. Refer to the Temporary Sediment Basin Sizing Calculation located in Appendix K. Several temporary sediment basins will be utilized as sediment forebays following construction. Installation Schedule: Temporary Sediment Basins shall be installed during grading activities. Maintenance and Temporary Sediment Basins shall be inspected weekly and Inspection: following storms. Sediment shall be removed when it reaches a depth of one foot, or half the design capacity whichever is less. Damage to basin embankments and slopes shall be repaired.
Permanent Description:
4.7.1 Temporary Sediment Basins
RETAIN SEDIMENT ON-SITE
T F A R D
Temporary An erosion control barrier, consisting of entrenched straw bales and siltation fencing, shall be installed around the perimeter of all proposed infiltration areas to prevent construction vehicles from impacting the area, to decrease the velocity of sheet flows and intercept, and detain small amounts of sediment from disturbed areas. Installation Schedule: The erosion control barrier shall be installed after clearing and grubbing. Maintenance and Silt fence shall be inspected weekly, following storms, and Inspection: daily during rainy periods. Damaged fencing shall be replaced. Concentrated flows shall be intercepted and rerouted. Sediment accumulations shall be removed when reaching a depth of 6-inches. Deteriorated fencing material shall be replaced. Used fencing shall be properly disposed of.
Permanent Description:
4.6.1 Protect Proposed Infiltration Areas
PREVENT SOIL COMPACTION
4.9
4.8
Description:
DEWATERING PRACTICES
x x
Good Housekeeping BMPs
22
Visible floating solids or foam shall not be discharged; An oil-water separator or suitable filtration device (such as a cartridge filter) that is designed to remove oil, grease, or other products if dewatering water is found to contain these materials shall be used;
All groundwater or stormwater discharged from excavations, trenches, foundations, vaults, or other similar point shall be treated by sediment basins, sediment traps, sediment socks, dewatering tanks, tube settlers or filtration systems specifically designed to remove sediment from the excavations. All dewatering practices shall conform to the following:
T F A R D
Temporary Temporary gravel or crushed stone construction entrances/exits or other means shall be used to minimize off-site movement of soil with vehicles. Construction access points shall be maintained to minimize tracking of soil onto public roads and existing parking lots to remain. If the rock entrance is not working to keep streets clean, then install wheel wash, sweep streets, or wash streets if wash water can be collected. Installation Schedule: Stabilized construction entrance shall be installed prior to clearing and grubbing. Maintenance and Stabilized construction entrances shall be inspected daily. Inspection: Gravel or crushed stone shall be added if the pad is no longer in accordance with the specifications. If the rock entrance is not working to keep streets clean, then install wheel wash, sweep streets, or wash streets if wash water can be collected. When sediment has been tracked off of the site, it shall be removed by the end of the same working day, or by the end of the next working day if track-out occurs on a non work day. Remove sediment by sweeping, shoveling or vacuuming roadways were sediment has been tracked-out.
Permanent Description:
ESTABLISH STABILIZED CONSTRUCTION ENTRANCE/EXIT
GOOD HOUSEKEEPING BMPS
5.1
Material Handling and Waste Management Establish Proper Material Staging Areas Designate Washout Areas Establish Proper Equipment/Vehicle Fueling and Maintenance Practices Allowable Non-Stormwater Discharges and Control Equipment/Vehicle Washing Spill Prevention and Control Plan
Good Housekeeping BMPs
23
Several management procedures and practices are proposed to prevent and/or reduce the discharge of pollutants to stormwater from solid or liquid wastes that will be generated at the site. These measures are grouped into the following categories: (1) solid or construction waste disposal, (2) recycling, (3) sanitary and septic waste, and (4) hazardous materials.
MATERIAL HANDLING AND WASTE MANAGEMENT
x x x x x x
This SWPPP contains a listing of the good housekeeping best management practices (BMPs) that shall be implemented to control pollutants in stormwater discharges during construction-related work. The BMPs are categorized below:
5.0
Maintenance and Inspection:
Installation Schedule:
To the extent feasible, utilize vegetated, upland areas of the site to infiltrate dewatering water before discharge. In no case will surface waters be considered part of the treatment area; x Velocity dissipaters shall be installed at all points where dewatering activities are discharged to the surface. x With backwash water, either haul it away for disposal or return it to the beginning of the treatment process; and x Replace and clean the filter media used in dewatering devices when the pressure differential equals or exceeds the manufacturer’s specifications. Install settling or filtration methods prior to commencing dewatering. Engineer is required to provide or approve settling of filtration method design prior to installation. Settling of filtration controls shall be inspected weekly and following storms. Sediment shall be removed when it reaches a depth of one foot, or half the design capacity whichever is less.
x
Installation Schedule: Maintenance and Inspection:
Description:
5.1.2 Recycling
Good Housekeeping BMPs
24
Wood pallets, cardboard boxes, and other recyclable construction scraps shall be disposed of in a designated dumpster for recycling. The dumpster shall have a secure watertight lid, be placed away from stormwater conveyances and drains and meet all local and state solid-waste management regulations. Only solid recyclable construction scraps from the site shall be deposited in the dumpster. All personnel shall be instructed regarding the correct procedure for disposal of recyclable construction scraps. Notices that state these procedures shall be posted in the office trailer, and the individual who manages day-to-day site operations shall be responsible for seeing that these procedures are followed. Designated recycling dumpsters shall be installed once the area has been established. The recycling dumpster shall be inspected weekly and immediately after storm events. The recycling dumpster shall be emptied weekly and taken to an approved recycling center. If recyclable
T F A R D
All waste materials shall be collected and disposed of into metal trash dumpsters in the materials storage area. Dumpsters shall have a secure watertight lid, be placed away from stormwater conveyances and drains, and meet all federal, state, and municipal regulations. Only trash and construction debris from the site shall be deposited in the dumpster. No construction materials shall be buried on-site unless authorized by a program for recycling/beneficial use. All personnel shall be instructed regarding the correct disposal of trash and construction debris. Notices that state these practices shall be posted in the office trailer and the individual who manages daytoday site operations shall be responsible for seeing that these practices are followed. Installation Trash dumpsters shall be installed once the materials storage area Schedule: has been established. Maintenance The dumpsters shall be inspected weekly and immediately after and storm events. The dumpsters shall be emptied weekly and taken to Inspection: an approved landfill or recycling facility. If trash and construction debris are exceeding the dumpsters’ capacity, the dumpsters shall be emptied more frequently. Waste container lids shall be closed when not in use and at the end of the business day. For waste containers that do not have lids, provide cover or a similarly effective means to minimize the discharge of pollutants.
Description:
5.1.1 Solid or Construction Waste Disposal
T F A R D
Temporary sanitary facilities (portable toilets) shall be provided at the site throughout the construction phase. The portable toilets shall be located in the staging area, away from concentrated flow paths and traffic flow. The portable toilets shall be brought to the site once the staging area has been established. All sanitary waste shall be collected from the portable facilities on a regular basis. The portable toilets shall be inspected weekly for evidence of leaking holding tanks. Toilets with leaking holding tanks shall be removed from the site and replaced with new portable toilets.
Installation Schedule: Maintenance and Inspection:
Description:
Good Housekeeping BMPs
25
All hazardous waste materials such as oil filters, petroleum products, paint, and equipment maintenance fluids shall be stored in structurally sound and sealed shipping containers, within the hazardous materials storage area. Hazardous waste materials shall be stored in appropriate and clearly marked containers and segregated from other non-waste materials. Secondary containment shall be provided for all waste materials in the hazardous materials storage area and shall consist of commercially available spill pallets. Additionally, all hazardous waste materials shall be disposed of in accordance with federal, state, and municipal regulations. Hazardous waste materials shall not be disposed of into the on-site dumpsters. All personnel shall be instructed regarding proper procedures for hazardous waste disposal. Notices that state these procedures shall be posted in the office trailer and the individual who manages day-to-day site operations shall be responsible for seeing that these procedures are followed. Shipping containers used to store hazardous waste materials shall be installed once the site materials storage area has been installed. The hazardous waste material storage areas shall be inspected weekly and after storm events. The storage areas shall be kept clean, well organized, and equipped with ample cleanup supplies as appropriate for the materials being stored. Material safety data sheets, material inventory, and emergency contact numbers shall be maintained in the office trailer.
5.1.4 Hazardous Materials and Waste
Installation Schedule: Maintenance and Inspection:
Description:
5.1.3 Sanitary and Septic Waste
construction wastes are exceeding the dumpsters’ capacity, the dumpsters shall be emptied more frequently.
5.3
5.2
All fertilizers, herbicides, insecticides and pesticides shall be stored in accordance with local, state, and federal regulations. At a minimum these materials shall be covered with plastic sheeting or a temporary roof to prevent contact with rainwater.
T F A R D
All hazardous-waste materials such as oil filters, petroleum products, paint, and equipment maintenance fluids shall be stored in structurally sound and sealed containers under cover within the storage area.
Construction equipment and maintenance materials shall be stored at the combined staging area and materials storage areas. A watertight shipping container shall be used to store hand tools, small parts, and other construction materials. Nonhazardous building materials such as packaging material (wood, plastic, and glass), and construction scrap material (brick, wood, steel, metal scraps, and pipe cuttings) shall be stored in a separate covered storage facility adjacent to the shipping container.
Description:
Good Housekeeping BMPs
26
A designated temporary, above-grade concrete washout area shall be constructed. The temporary concrete washout area shall be constructed with a recommended minimum length and minimum width of 10 feet, but with sufficient quantity and volume to contain all liquid and concrete waste generated by washout operations. The washout area shall be lined with plastic sheeting at least 10 mils thick and free of any holes or tears. Signs shall be posted marking the location of the washout area to ensure that concrete equipment operators use the proper facility.
5.3.1 Concrete Washout
DESIGNATE WASHOUT AREAS
Very large items, such as framing materials and stockpiled lumber, shall be stored in the open in the materials storage area. Such materials shall be elevated on wood blocks to minimize contact with runoff. Installation The materials storage area shall be installed after grading and before any Schedule: infrastructure is constructed at the site. Maintenance The storage area shall be inspected weekly and after storm events. The and storage area shall be kept clean, well organized, and equipped with ample Inspection: cleanup supplies as appropriate for the materials being stored. Perimeter controls, containment structures, covers, and liners shall be repaired or replaced as needed to maintain proper function.
Description:
ESTABLISH PROPER MATERIAL STAGING AREAS
T F A R D Installation Schedule:
Description:
Good Housekeeping BMPs
27
A designated temporary, above-grade washout area shall be constructed as needed for the washout and cleanout of stucco, paint, or other non-hazardous construction materials. The temporary washout area shall be a leak-proof container with sufficient volume to contain all liquid and waste generated by washout operations. The temporary washout shall be sited outside of all buffer zones. The washout area shall be constructed as needed.
5.3.2 Applicators, Containers and Paint Washout
Design Specifications: 1. Temporary concrete washout type Above Grade shall be constructed as shown above, with a recommended minimum length and minimum width of 10 feet. 2. The washout shall be a minimum of 50 feet from storm drain inlets. 3. Plastic lining shall be free of holes, tears, or other defects that compromise the impermeability of the material.
Installation Schedule: Maintenance and Inspection:
Concrete pours shall not be conducted during or before an anticipated storm event. Concrete mixer trucks and chutes shall be washed in the designated area or concrete wastes shall be properly disposed of off-site. When the temporary washout area is no longer needed for the construction project, the hardened concrete and materials used to construct the area shall be removed and disposed of according to the maintenance section below, and the area shall be stabilized. The washout area shall be constructed before concrete pours occur at the site. The washout areas shall be inspected daily to ensure that all concrete washing is being discharged into the washout area, no leaks or tears are present, and to identify when concrete wastes need to be removed. The washout areas shall be cleaned out once the area is filled to 75 percent of the holding capacity. Once the area’s holding capacity has been reached, the concrete wastes shall be allowed to harden; the concrete shall be broken up, removed, and taken to an approved landfill for disposal or recycled on-site or offsite in accordance with applicable laws. The plastic sheeting shall be replaced if tears occur during removal of concrete wastes from the washout area.
5.5
5.4
Description:
DISCHARGES
AND
CONTROL
Good Housekeeping BMPs
28
All equipment and vehicle washing shall be performed off-site, except as required for wheel washes and concrete washout areas.
ALLOWABLE NON-STORMWATER EQUIPMENT / VEHICLE WASHING
Several types of vehicles and equipment will likely be used on-site throughout the project, including graders, scrapers, excavators, loaders, paving equipment, rollers, trucks and trailers, backhoes, and forklifts. All major equipment/vehicle fueling and maintenance shall be performed outside of wetland buffer zones. When vehicle fueling must occur on-site, the fueling activity shall occur in the staging area. Only minor equipment maintenance shall occur on-site. All equipment fluids generated from maintenance activities shall be disposed of into designated drums stored on spill pallets in accordance with the Material Handling and Waste Management Section. Absorbent, spill-cleanup materials and spill kits shall be available at the combined staging and materials storage area. Drip pans shall be placed under all equipment receiving maintenance and vehicles and equipment parked overnight. Installation BMPs implemented for equipment and vehicle maintenance and fueling Schedule: activities shall begin at the start of the project. Maintenance Inspect equipment/vehicle storage areas weekly and after storm events. and Vehicles and equipment shall be inspected on each day of use. Leaks shall Inspection: be repaired immediately, using dry cleanup measures where possible and eliminating the source of the discharge. Problem vehicle(s) or equipment shall be removed from the project site. Keep ample supply of spill-cleanup materials on-site and immediately clean up spills and dispose of materials properly. Do not clean surfaces by hosing-down the area
Description:
T F A R D
The washout areas shall be inspected daily to ensure that all washing is being discharged into the washout area, no leaks or tears are present, and to identify when wastes need to be removed. The washout areas shall be cleaned out once the area is filled to 75 percent of the holding capacity. Liquid wastes shall be disposed of in accordance with applicable Federal and State requirements and shall not be discharged into drainage systems.
ESTABLISH PROPER EQUIPMENT/VEHICLE FUELING AND MAINTENANCE PRACTICES
Maintenance and Inspection:
5.7
5.6
T F A R D Description:
Good Housekeeping BMPs
29
Discharges from fertilizers containing nitrogen and phosphorus shall be minimized. Fertilizers shall be applied at rates and amounts consistent with the manufacture’s specification, and shall at no time exceed local, state, or federal specifications. See project landscape specifications for acceptable fertilizers that can be used for the project.
FERTILIZER DISCHARGE RESTRICTIONS
i.
Employee Training: All employees shall be trained as detailed in the Inspection and Maintenance section of this report. ii. Vehicle Maintenance: Vehicles and equipment shall be maintained off-site. All vehicles and equipment including subcontractor vehicles shall be checked for leaking oil and fluids. Vehicles leaking fluids shall not be allowed on-site. iii. Hazardous Material Storage: Hazardous materials shall be stored in accordance with this report and federal and municipal regulations. iv. Spill Kits: Spill kits shall be kept within the materials storage area. Spills: All spills shall be cleaned up immediately upon discovery. Spent absorbent materials and rags shall be hauled off-site immediately after the spill is cleaned up for disposal at an approved landfill. Spills large enough to discharge to surface water shall be reported to the National Response Center at 1-800-424-8802 and MA DEP at 617-792-7653. v. Material safety data sheets: A material inventory and emergency contact information shall be maintained at the on-site project trailer. Installation The spill prevention and control procedures shall be implemented once Schedule: construction begins on-site. Maintenance All personnel shall be instructed the correct procedures for spill prevention and and control. Notices that state these practices shall be posted in the office Inspection: trailer, and the individual who manages day-to-day site operations shall be responsible for seeing that these procedures are followed.
Description:
SPILL PREVENTION AND CONTROL PROCEDURES
Installation N/A Schedule: Maintenance N/A and Inspection:
x x x x x x x x x
Water Used to Control Dust Uncontaminated Excavation Dewatering Landscape Irrigation Fire Hydrant Flushing Firefighting Potable Water including uncontaminated waterline flushing Non-Detergent Laden Vehicle Wash Water Foundation or Footing Drains Uncontaminated air conditioning or compressor condensate
The following is a list of allowable non-stormwater discharges:
T F A R D
Good Housekeeping BMPs
30
Any changes in construction activities that produce other allowable non-stormwater discharges shall be identified, and the SWPPP shall be amended and the appropriate erosion and sediment control shall be implemented.
ALLOWABLE NON-STORMWATER DISCHARGE MANAGEMENT
Except for water used to control dust and irrigation water, the above discharges shall not be routed to areas of exposed soil.
5.8
Fertilizers shall be applied at an appropriate time of year, timed to coincide as closely as possible to the period of maximum vegetation uptake and growth. Avoid applying fertilizers before heavy rains. Do not apply fertilizers to frozen ground or stormwater conveyance channels flowing with water. Maintenance N/A and Inspection:
Installation Schedule:
6.2
T F A R D
The basins shall be inspected weekly and after storm events greater than 0.5 inches during construction. The area shall be checked for signs of erosion, seepage, and structural damage. Erosion, seepage, and structural damage shall be repaired immediately. The temporary sediment riser shall be checked for any damage or obstructions and any damage found shall be repaired and obstructions removed. Immediately after the completion of construction, the plant material shall be watered for 14 consecutive days unless there is sufficient natural rainfall. The area shall be monitored until final stabilization is reached. Following completion of site construction and final stabilization, maintenance and inspection responsibilities shall be taken over by the Owner in accordance with the Long-Term Pollution Prevention Plan and Long-Term Operation & Maintenance Plan.
Infiltration basins shall be excavated during earthwork construction.
Design Specifications: Installation Schedule: Maintenance and Inspection:
Description:
Final Stabilization
31
See Section 5 for maintenance and inspection procedures for the grass drainage channel. Following completion of site construction and final stabilization, maintenance and inspection responsibilities shall be taken over by the Owner in accordance with the Long-Term Pollution Prevention Plan and Long-Term Operation & Maintenance Plan.
Grass drainage channels shall be installed before site grading begins.
Some of the grass drainage channels shall remain as a permanent stormwater management structures for the site. The channels shall convey runoff to stormwater inlets throughout the site. Install according to sitework specifications and details.
GRASS DRAINAGE CHANNELS
Design Specifications: Installation Schedule: Maintenance and Inspection:
Infiltration basins shall be protected from stormwater runoff from the disturbed site during construction. Riprap spillways shall be constructed as detailed on the site plan. Install according to sitework specifications and details.
INFILTRATION BASIN
6.1 Description:
POST-CONSTRUCTION BMPS
6.0
FINAL STABILIZATION
T F A R D
Preparing the soil for vegetative or non-vegetative stabilization; applying mulch or other non-vegetative product to the exposed area; seeding or planting the exposed area; starting any of the activities in listed above on a portion of the area to be stabilized, but not on the entire area; and finalizing arrangements to have stabilization product fully installed in compliance with the applicable deadline for completing stabilization.
For vegetative stabilization, all activities necessary to initially seed or plant the area to be stabilized; and/or For non-vegetative stabilization, the installation or application of all such non-vegetative measures.
7.1
Description:
Final Stabilization
32
Permanent seeding shall be applied immediately after the final design grades are achieved on portions of the site but no later than 7 days after construction activities have permanently ceased. After the entire site is stabilized, any sediment that has accumulated shall be removed and hauled off-site for disposal at an approved landfill. Construction debris, trash and temporary BMPs (including silt fences, material storage areas, sanitary toilets, and inlet protection) shall also be removed and any areas disturbed during removal shall be seeded immediately. Seeding shall be performed in accordance to the Site Plans and Landscape Specifications for the project.
PERMANENT SEEDING
The following sections detail the management practices proposed to achieve final stabilization of the site.
x
x
As soon as practicable, but no later than 7 calendar days after the initiation of soil stabilization measures the following activities are required to be completed:
x
x x x x
In the context of this provision, “immediately” means as soon as practicable, but no later than the end of the next work day, following the day when the earth-disturbing activities have temporarily or permanently ceased. The following activities constitute the initiation of stabilization:
In compliance with the Construction General Permit, soil stabilization measures must be implemented immediately whenever earth-disturbing activities are temporarily or permanently ceased on any portion of the site. Earth-disturbing activities are temporarily ceased when clearing, grading, and excavation within any area of a site that will not include a permanent structure will not resume for a period of 7 or more calendar days, but such activities will resume in the future.
7.0
Maintenance and Inspection:
Installation Schedule:
T F A R D
Final Stabilization
33
Seeding shall occur at portions of the site where construction activities have permanently ceased shall be stabilized, as soon as possible but no later than 14 days after construction ceases. All seeded areas shall be inspected weekly during construction activities for failure and after storm events until a dense cover of vegetation has been established. If failure is noticed at the seeded area, the area shall be reseeded, fertilized, and mulched immediately. After construction is completed at the site, permanently stabilized areas shall be monitored until final stabilization is reached.
INSPECTIONS
8.1
Inspections and Maintenance
For detailed inspection procedures, see Sections 4 and 5.
34
Utility line installation, pipeline construction, and other examples of long, narrow, linear construction activities may limit the access of inspection personnel to the areas described in the above paragraph. Inspection of these areas could require that vehicles compromise temporarily or even permanently stabilized areas, cause additional disturbance of soils, and increase the potential for erosion. In these circumstances, controls shall be inspected on the same frequencies as other construction projects, but representative inspections may be performed. For representative inspections, personnel shall inspect controls along the construction site for 0.25 mile above and below each access point where a roadway, undisturbed right-of-way, or other similar feature intersects the construction site and allows access to the areas described above. The conditions of the controls along each inspected 0.25 mile segment may be considered as representative of the condition of controls along that reach extending from the end of the 0.25 mile segment to either the end of the next 0.25 mile inspected segment, or to the end of the project, whichever occurs first.
T F A R D
Inspections shall include all areas of the site disturbed by construction activity and areas used for storage of materials that are exposed to precipitation. Inspectors shall look for evidence of, or the potential for, pollutants entering the storm water conveyance system. Sedimentation and erosion control measures identified in the SWPPP shall be observed to ensure proper operation. Discharge locations shall be inspected to ascertain whether erosion control measures are effective in preventing significant impacts to waters of the United States, where accessible. Where discharge locations are inaccessible, nearby downstream locations shall be inspected to the extent that such inspections are practicable. Locations where vehicles enter or exit the site shall be inspected for evidence of off-site sediment tracking.
Inspections of the site will be performed once every 7 days and within 24 hours of the end of a storm event of 0.25-inch or greater unless otherwise specified. The inspections will verify that all BMPs required are implemented, maintained, and effectively minimizing erosion and preventing stormwater contamination from construction materials.
8.1.1 Inspection Schedule and Procedures
INSPECTIONS AND MAINTENANCE
8.0
8.3
8.2
T F A R D
See Appendix F – Corrective Action Log.
Inspections and Maintenance
35
If it is determined the stormwater controls have not been installed as required, or that they are not functioning adequately corrective action is required within 7 calendar days.
The corrective action log describes repairs, replacements, and maintenance of BMPs undertaken as a result of the inspections and maintenance procedures. Additionally, remedies of permit violations and clean and proper disposal of spills, releases other deposits should be recorded.
CORRECTIVE ACTION LOG
If earth-disturbing activities are suspended due to frozen conditions inspections can be temporarily suspended until a thaw occurs.
Once an area is stabilized, inspections may be reduced to once per month. If construction resumes at the stabilized area the inspection frequency shall increase as outlined in section 8.1.
REDUCTIONS IN INSPECTION FREQUENCY
For a copy of the inspection report template, see Appendix E.
Inspection reports are required to be completed within 24-hours of an inspection. If corrective actions are identified by the Inspector during the inspection, he/she shall notify and submit a copy of the inspection report to the Operator(s). For corrective actions identified, the project managers shall be responsible for initiating the corrective action within 24 hours of the report and completing maintenance as soon as possible or before the next storm event. For any corrective actions requiring a SWPPP amendment or change to a stormwater conveyance or control design, the project manager shall notify the Owner, as soon as possible, before initiating the corrective action.
All inspections shall be coordinated with a representative from Clean Energy Collective. A Clean Energy Collective representative shall accompany Name of inspector, when possible, during inspections.
9.3
9.2
RECORDKEEPING
9.1
Company/Organization: TBD Name: TBD
9.3.1 Individual(s) Responsible for Training
Record Keeping and Training
36
Prior to the commencement of earth-disturbing activities or pollutant-generating activities, whichever occurs first, training on the pollution prevention measures outlined in this SWPPP shall be provided to staff and subcontractors.
TRAINING
The log of changes to the SWPPP is maintained in Appendix G and includes additions of new BMPs, replacement of failed BMPs, significant changes in the activities or their timing on the project, changes in personnel, changes in inspection and maintenance procedures and update to site plans.
LOG OF CHANGES TO THE SWPPP
Date(s) when an area is either temporarily or permanently stabilized: See Appendix I – Grading and Stabilization Activities Log
Date(s) when construction activities temporarily or permanently cease on a portion of the site: See Appendix I – Grading and Stabilization Activities Log
T F A R D
Date(s) when major grading activities occur: See Appendix I – Grading and Stabilization Activities Log
The following records shall be kept at the project site and shall be available for inspectors to review. These records shall be retained for a minimum period of at least 3 years after the permit is terminated.
A copy of the SWPPP, along with all inspection reports and corrective action logs are required to be stored at an accessible location at the site, and shall be made available upon request of the EPA, or state or local agency approving stormwater management plans.
RECORDKEEPING AND TRAINING
9.0
Record Keeping and Training
T F A R D
37
Formal training shall be provided to all staff and subcontractors with specific stormwater responsibilities, such as installing and maintaining BMPs. The formal training shall cover all design and construction specifications for installing the BMPs and proper procedures for maintaining each BMP. Formal training shall occur before any BMPs are installed on the site. (See Appendix J – Training Log)
Informal training shall be conducted for all staff, including subcontractors, on the site. The training shall be conducted primarily via tailgate sessions and shall focus on avoiding damage to stormwater BMPs and preventing illicit discharges. The tailgate sessions shall be conducted biweekly and shall address the following topics: Erosion Control BMPs, Sediment Control BMPs, Non-Stormwater BMPs, Waste Management and Materials Storage BMPs, and Emergency Procedures specific to the construction site. (See Appendix J – Training Log)
9.3.2 Description of Training Conducted
SIGNATURE, PLAN REVIEW, AND MAKING PLANS AVAILABLE
10.1
T F A R D
NOTICE OF PERMIT COVERAGE
x
x x x
Certification and Notification
38
The NPDES Permit Tracking Number, A contact name and phone number for obtaining additional construction site information, The Uniform Resource Locator (URL) for the SWPPP (if available), or the following statement: “If you would like to obtain a copy of the Stormwater Pollution Prevention Plan (SWPPP) for this site, contact the EPA Regional 1 Office at (617) 918-1038, The following statement “If you observe indicators of stormwater pollutants in the discharge or in the receiving waterbody, contact the EPA through the following website: https://www.epa.gov/enforcement/report-environmental-violations.”
A sign must be posted at a safe, publicly accessible location in close proximity to the construction site detailing the permit coverage. The notice must be located so that it is visible from the public road that is nearest to the active part of the construction site, and it must use a font large enough to be readily viewed from a public right-of-way. At a minimum, the notice must include:
10.2
A copy of the SWPPP (including a copy of the Construction General Permit, NOI, and acknowledgement letter from EPA shall be retained at the construction site (or other location easily accessible during normal business hours to EPA, a state, tribal or local agency approving sediment and erosion plans, grading plans, or storm water management plans; local government officials; the operator of a municipal separate storm sewer receiving discharges from the site; and representatives of the U.S. Fish and Wildlife Service or the National Marine Fisheries Service) from the date of commencement of construction activities to the date of final stabilization. A copy of the SWPPP shall be available at a central location on-site for the use of all those identified as having responsibilities under the SWPPP. If an on-site location is unavailable to store the SWPPP when no personnel are present, notice of the plan’s location shall be posted near the main entrance at the construction site.
CERTIFICATION AND NOTIFICATION
10.0
000000RP000
Project Name Stormwater Pollution Prevention Plan (SWPPP) Town, Massachusetts
10.3
Certification and Notification
T F A R D
Signature:________________________________ Date:_______________________
Name:___________________________________ Title:_______________________
39
I certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gathered and evaluated the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations.
OWNER CERTIFICATION
10.4
Certification and Notification
T F A R D
Signature:________________________________ Date:_______________________
Name:___________________________________ Title:_______________________
40
I certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gathered and evaluated the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations.
OPERATOR CERTIFICATION
T F A R D
APPENDICES
T F A R D General Location Map
Appendix A
T F A R D
Site Plans
Appendix B
Appendix C
https://www.epa.gov/sites/production/files/2017-02/documents/2017_cgp_final_permit_508.pdf
Construction General Permit
T F A R D
Appendix D NOI and Acknowledgement Letter from EPA
T F A R D
Inspection Reports
Appendix E
The following four pages should be copied and completed for each inspection. All inspection forms should be compiled in a binder to prove compliance with this SWPPP.
Inspections under this SWPPP shall be conducted in accordance with each installed BMPs recommended maintenance requirements. This inspection frequency may be reduced to at least once every month if: a) the entire site is temporarily stabilized, b) runoff is unlikely due to winter conditions (e.g. site is covered with snow, ice, or the ground is frozen), or c) construction is occurring during seasonal arid periods in arid areas and semi-arid areas. If an inspection report is filed according to this modified schedule it shall be noted at the end of the report under the “NOTES” section.
T F A R D
Are there any discharges at the time of inspection? Yes If yes, describe:
No
High Winds No
Fog Snowing Temperature: Have any discharges occurred since the last inspection? Yes If yes, describe:
Weather at time of this inspection? Clear Cloudy Rain Sleet Other:
Approx. Amount of Precipitation (in):
During storm event Post-storm event Weather Information Has there been a storm event since the last inspection? Yes No If yes, provide: Storm Start Date & Time: Storm Duration (hrs):
Inspector’s Contact Information Inspector’s Qualifications Describe present phase of construction Type of Inspection: Regular Pre-storm event
Inspector’s Title(s)
T F A R D
Start/End Time
Date of Inspection Inspector’s Name(s)
Location
General Information
NPDES Tracking No.
Project Name
Stormwater Pollution Prevention Plan: Inspection Checklist
E-1
BMP
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Corrective Action Needed and Notes
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
T F A R D
BMP Maintenance Required?
BMP Installed?
E-2
Site-specific BMPs x Number the structural and non-structural BMPs identified in your SWPPP on your site map and list them below (add as many BMPs as necessary). Carry a copy of the numbered site map with you during your inspections. This list will ensure that you are inspecting all required BMPs at your site. x Describe corrective actions initiated, date completed, and note the person that completed the work in the Corrective Action Log.
Are vehicle and equipment fueling, cleaning, and maintenance areas free of spills, leaks, or any other deleterious material?
Are washout facilities (e.g., paint, stucco, concrete) available, clearly marked, and maintained?
Is trash/litter from work areas collected and placed in covered dumpsters?
Is the construction exit preventing sediment from being tracked into the street?
Are storm drain inlets properly protected?
Are discharge points and receiving waters free of any sediment deposits?
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Maintenance Required?
E-3
Corrective Action Needed and Notes
T F A R D
Yes No
Are natural resource areas (e.g., streams, wetlands, mature trees, etc.) protected with barriers or similar BMPs?
Yes No
Yes No
Are all slopes and disturbed areas not actively being worked properly stabilized?
Are perimeter controls and sediment barriers adequately installed (keyed into substrate) and maintained?
Implemented?
BMP/activity
Overall Site Issues Below are some general site issues that should be assessed during inspections. Customize this list as needed for conditions at your site.
Yes No
Yes No
Yes No
Yes No
Are non-stormwater discharges (e.g., wash water, dewatering) properly controlled?
(Other)
Corrective Action Needed and Notes
Date:_____________________
Signature:_________________________________________________________
___________________________________________________________________________
Print name and title:
E-4
“I certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gathered and evaluated the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations.”
CERTIFICATION STATEMENT
Describe any incidents of non-compliance not described above:
Non-Compliance
T F A R D
Yes No
Yes No
Are materials that are potential stormwater contaminants stored inside or under cover?
Maintenance Required?
Implemented?
BMP/activity
T F A R D
Corrective Action Log
Appendix F
Date
Additional Action Items
T F A R D
Activity Description
F-1
Use this form to note the date and activity for accurate record keeping (make additional copies as necessary). Examples include the restaking or reinforcement of the erosion control barrier, site watering to prevent dust erosion, street sweeping, equipment and machinery repair, etc.
Corrective Action Log
Appendix G
Based on the results of an inspection, the SWPPP shall be modified as necessary to include additional or modified BMPs designed to correct problems identified. Revisions to the SWPPP shall be completed within seven (7) calendar days following the inspection. Implementation of these additional or modified BMPs shall be accomplished as described in Subpart 3.6B of the Construction General Permit (located in Appendix C).
The SWPPP shall be amended if during inspections or investigations by site staff, or by local, state, tribal or federal officials, it is determined that the SWPPP is ineffective in eliminating or significantly minimizing pollutants in storm water discharges from the construction site.
The SWPPP, including the site plans, shall be amended whenever there is a change in design, construction, operation, or maintenance at the construction site that has or could have a significant effect on the discharge of pollutants to the waters of the United States that has not been previously addressed in the SWPPP.
SWPPP Amendment Log
T F A R D
Amendment No.
Date of Amendment
T F A R D
Description of the Amendment
SWPPP Amendment Log
G-1
Amendment Prepared by (Name(s) and Title)
Appendix H Subcontractor Certifications/Agreements
T F A R D
T F A R D
Date:
Title:
Signature:
Type of construction service to be provided:
Telephone Number:
Address:
Company:
This certification is hereby signed in reference to the above named project:
I certify under the penalty of law that I have read and understand the terms and conditions of the SWPPP for the above designated project and agree to follow the practices described in the SWPPP.
Each subcontractor engaged in activities at the construction site that could impact stormwater must be identified and sign the following certification statement:
As a subcontractor, you are required to comply with the Stormwater Pollution Prevention Plan (SWPPP) for any work that you perform on-site. Any person or group who violates any condition of the SWPPP may be subject to substantial penalties or loss of contract. You are encouraged to advise each of your employees working on this project of the requirements of the SWPPP. A copy of the SWPPP is available for your review at the office trailer.
Operator(s):
Project Title:
Project Number:
SUBCONTRACTOR CERTIFICATION STORMWATER POLLUTION PREVENTION PLAN
Sample Subcontractor Certifications/Agreements
Appendix I
Site Plans in Appendix B should be annotated to indicate areas where final stabilization has been accomplished and no further construction-phase permit requirements apply.
Grading and Stabilization Activities Log
T F A R D
Date
Description
T F A R D
Location on Property
Grading and Stabilization Activities Log
I-1
The following records are to be kept by each Site Operator throughout the construction period and maintained in the SWPPP. Insert additional documentation for record keeping as necessary.
T F A R D
Training Log
Appendix J
Date
Training Log Attendee
T F A R D
Training Topic
Signature of Training Coordinator
J-1
T F A R D
Delegation of Authority
Appendix K
Date:
Signature:
Title:
Company:
Name:
I certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gathered and evaluated the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations.
By signing this authorization, I confirm that I meet the requirements to make such a designation as set forth in Appendix I of EPA’s Construction General Permit (CGP), and that the designee above meets the definition of a “duly authorized representative” as set forth in Appendix I.
T F A R D
________________________________________ (name of person or position) ________________________________________ (company) ________________________________________ (address) ________________________________________ (city, state, zip) ________________________________________ (phone)
I, _______________________ (name), hereby designate the person or specifically described position below to be a duly authorized representative for the purpose of overseeing compliance with environmental requirements, including the Construction General Permit, at the ____________________________________ construction site. The designee is authorized to sign any reports, stormwater pollution prevention plans and all other documents required by the permit.
Delegation of Authority
Sample Delegation of Authority Form
Appendix L Endangered Species Documentation
T F A R D
Appendix M
Historic Preservation Documentation
T F A R D
Appendix N Temporary Sediment Basin Sizing Calculations
T F A R D
Appendix O
Natural Buffer Equivalency Calculations
T F A R D
Section 5.0 Plans Locus Map Aerial Map Entitled “CEC #1206, LLC in Hopkinton, Massachusetts (Middlesex County)” Prepared by Beals and Thomas, Inc. In 19 Sheets Dated August 10, 2017
Site
HOPKINTON MILFOR D
Digital USGS Map of Milford, MA, dated 1982, provided by the Office of Geographic and Environmental Information (MassGIS), Commonwealth of Massachusetts Executive Office of Energy and Environmental Affairs.
Z 0 FEET
1,000
2,000
4,000
PROJECT:
Figure 1
Hopkinton, Massachusetts
CEC Solar #1206, LLC c/o Clean Energy Collective 146 West Boylston Drive, 3rd Floor Worcester, MA 01606
BEALS+ THOMAS
NORTH
COP YRIGHT (C) BY BEALS AND TH OMAS , INC. ALL RIGHTS RES ERVE D
Locus Map
CEC Solar #1206, LLC
PREPARED FOR:
North Arrow
Scale: 1" = 2,000'
Date: 03/29/2017
Source File 283600P007A.mxd B+T Project No. 2836.00
North Arrow
Z
Digital Globe, MassGIS Digital orthophotograph, dated 2015, provided by the Office of Geographic and Environmental Information (MassGIS), Commonwealth of Massachusetts Executive Office of Energy and Environmental Affairs.
0 FEET
155
310
620
PROJECT:
Aerial Map
CEC Solar #1206, LLC
Figure 2
Hopktinton, Massachusetts
PREPARED FOR:
CEC Solar #1206, LLC c/o Clean Energy Collective 146 West Boylston Drive, 3rd Floor Worcester, Massachusetts
BEALS+ THOMAS
NORTH
COP YRIGHT (C) BY BEALS AND TH OMAS , INC. ALL RIGHTS RES ERVE D
Scale: 1" = 300'
Date: 03/29/2017
Source File 283600P008A.mxd B+T Project No. 2836.00
CEC Solar #1206, LLC Stormwater Management Report Hopkinton, Massachusetts 283600RP001A
TABLE OF CONTENTS 1.0
INTRODUCTION .............................................................................................................................................. 1
2.0
PRE-DEVELOPMENT CONDITIONS........................................................................................................... 2
2.1 2.2 2.3 3.0
SITE CONDITIONS ............................................................................................................................................ 2 SOIL DESCRIPTION .......................................................................................................................................... 2 HYDROLOGIC ANALYSIS .................................................................................................................................. 3
POST-DEVELOPMENT CONDITIONS ........................................................................................................ 3
3.1 3.2 3.3 3.4 3.5 3.6
DESIGN STRATEGY ........................................................................................................................................... 3 HYDROLOGIC ANALYSIS .................................................................................................................................. 3 STORMWATER MANAGEMENT CONTROLS SIZING ............................................................................................ 3 COMPLIANCE WITH DEP STORMWATER MANAGEMENT STANDARDS .............................................................. 3 ILLICIT DISCHARGE COMPLIANCE STATEMENT ................................................................................................ 6 DEP’S CHECKLIST FOR A STORMWATER REPORT ............................................................................................ 7
LIST OF APPENDICES APPENDIX A: SOIL DATA APPENDIX B: PRE-DEVELOPMENT HYDROLOGIC ANALYSIS APPENDIX C: POST-DEVELOPMENT HYDROLOGIC ANALYSIS APPENDIX D: DRAWDOWN & RIPRAP-SIZING CALCULATIONS APPENDIX E: SITE OWNER’S MANUAL APPENDIX F: STORMWATER POLLUTION PREVENTION PLAN
Table of Contents
i
CEC Solar #1206, LLC Stormwater Management Report Hopkinton, Massachusetts 283600RP001
1.0
INTRODUCTION
The proposed project includes a stormwater management system designed to mitigate potential impacts the proposed project could have on the existing watershed. Stormwater controls have been proposed to control peak runoff rates, provide water quality, promote groundwater recharge, and sediment removal. The proposed system has been designed to comply with: •
The 2008 Massachusetts Department of Environmental Protection (DEP) Stormwater Management Handbook,
• •
The Massachusetts Wetland Protection Act (310 CMR 10.00), and Town of Hopkinton Wetlands Protection Regulations
The pre- and post-development hydrologic conditions were modeled using HydroCADTM version 10.00 to demonstrate that post-development stormwater runoff rates will be less than or equal to the pre-development rates. Watershed maps with soil types as well as detailed analysis of the model results are also included. The following table summarizes the peak runoff rates and volumes for the pre- and post-development conditions. Table 1: Pre- & Post-development Peak Runoff Rate Comparison, units are in cubic feet per second (cfs).
Storm Event Design Point 1 Design Point 2 Design Point 3
2 Year Pre Post 0.00 0.00 0.22 0.19 0.22 0.14
10 Year Pre Post 0.04 0.00 1.95 1.81 2.35 1.85
25 Year Pre Post 0.27 0.26 4.21 4.10 5.29 5.19
100 Year Pre Post 3.08 2.24 10.21 10.19 13.23 12.24
1
CEC Solar #1206, LLC Stormwater Management Report Hopkinton, Massachusetts 283600RP001
2.0
PRE-DEVELOPMENT CONDITIONS
2.1
Site Conditions The proposed ground-mounted solar facility is located on an approximately 11.4-acre site (the Site) which is partially developed and occupied by a single-family residence. The solar array is proposed within an area that is comprised of predominantly woodland vegetation. The array is accessed off of the existing driveway associated with the dwelling on Lumber Street. The array is approximately centered on a high-point. Runoff from the Site drains to the east and to the west. There are on-site bordering vegetated wetlands (BVW) at the eastern perimeter of the Site as well as a potential vernal pool (PVP) and associated isolated vegetated wetland (IVW) at the southeastern quadrant. There is also a BVW at the western perimeter of the Site (adjacent to Lumber Street). The resource areas at northeastern and western portions of the Site ultimately flow to the north. The southeastern potion of the Site (including the PVP and IVW) flow to the east and south. These three locations described serve as the design points evaluated in the hydrologic analysis. A portion of the Site is within an Outstanding Resource Water (ORW). As described below, the project is proposed in accordance with Massachusetts DEP Stormwater Management Policy.
2.2
Soil Description The Natural Resources Conservation Service (NRCS) Web Soil Survey lists the on-site soils as Canton Fine Sandy Loam, Narragansett Silt Loam, and some areas of Ridgebury Fine Sandy Loam. Canton Fine Sandy Loam is a very deep, well-drained soil on glaciated uplands. The typical soil profile is comprised of layers of fine sandy loam over gravelly fine sandy loam, over gravelly loamy sand. NRCS classifies these soils as Hydrologic Soil Group (HSG) “A” (extremely bouldery) & “B” (extremely stony). Narragansett Silt Loam is a deep, well drained soil on glacial till plains and ground moraine. The typical soil profile is comprised of layers of silt loam over very gravelly loamy sand. NRCS classifies this soil as HSG “A”. Ridgebury Fine Sandy Loam is a very deep, poorly drained to somewhat poorly drained soil on glacial till uplands. The typical soil profile is comprised of layers of fine sandy loam over loamy fine sand, sand, and gravelly coarse sand. NRCS classifies this soil as HSG “D”.
2
CEC Solar #1206, LLC Stormwater Management Report Hopkinton, Massachusetts 283600RP001
2.3
Hydrologic Analysis Sub-catchment areas were delineated based on existing runoff patterns and topographic information. This information is shown on the Pre-Development Conditions Hydrologic Areas Map included in Appendix B. Summaries of each area with respect to Curve Number and Time of Concentration calculations can be found in the model results also in Appendix B.
3.0
POST-DEVELOPMENT CONDITIONS
3.1
Design Strategy The proposed solar array will include stormwater management measures to control peak rates of runoff from the Site. During the design phase of the site layout, consideration was given to minimizing the impact on the existing Site hydrology. To achieve this, grading was minimized to the maximum extent practicable and the Site was designed to match existing terrain where feasible, in order to maintain drainage patterns to maximum extent practicable. Stormwater runoff is directed to the proposed Best Management Practices (BMPs) via overland flow, with diversion berms and conveyance swales, if needed.
3.2
Hydrologic Analysis The established design points used in the pre-development conditions analysis were used in the post-development analysis for direct comparison. The tributary areas and flow paths were modified to reflect post-development conditions. See Appendix C for the Post- Development Conditions Hydrologic Areas Map. Summaries of each area with respect to Curve Number and Time of Concentration calculations can be found in the model results in Appendix C.
3.3
Stormwater Management Controls Sizing Infiltration Basin The three proposed stormwater infiltration basins have been designed to reduce peak runoff rates. All three basins have one to three pipe outlets and a riprap emergency spillway. The basins have been modeled with a conservative infiltration rate of 0.27 inches per hour consistent with HSG “C” soils, though the basins are proposed in areas mapped as HSG “A” & “B”. The basins dewater within 72 hours, as demonstrated by the drawdown calculations in Appendix D.
3.4
Compliance with DEP Stormwater Management Standards The proposed stormwater management system was designed in compliance with the ten (10) DEP Stormwater Management Standards. The following summary provides key information related to the proposed stormwater management system, its design elements, and mitigation measures for potential impacts.
3
CEC Solar #1206, LLC Stormwater Management Report Hopkinton, Massachusetts 283600RP001
STANDARD 1:
No new stormwater conveyance (e.g. outfalls) may discharge untreated stormwater directly to or cause erosion in wetlands or waters of the Commonwealth.
Existing drainage patterns will be maintained. There are no contiguous impervious ground surfaces proposed, with the exception of relatively minor equipment pads. Three infiltration basins have been designed to mitigate stormwater runoff rates associated with the proposed project. Outlets from the basins have been designed to minimize the potential for erosion.
STANDARD 2:
Stormwater management systems shall be designed so that postdevelopment peak discharge rates do not exceed pre-development peak discharge rates.
The stormwater management design will control post-development peak discharge rates for the 2-, 10-, 25-, and 100-year, 24-hour storms so as to maintain pre-development peak discharge rates. Refer to Section 1.0 Introduction for a summary of the peak runoff rates.
STANDARD 3:
Loss of annual recharge to groundwater shall be eliminated or minimized through the use of environmentally sensitive site design, low impact development techniques, stormwater management practices and good operation and maintenance. At a minimum, the annual recharge from the post-development site shall approximate the annual recharge from pre-development conditions based on soil types. This Standard is met when the stormwater management system is designed to infiltrate the required recharge volume as determined in accordance with the Massachusetts Stormwater Handbook.
Groundwater recharge will be maintained as no contiguous impervious ground surfaces are proposed as part of this project, with the exception of two relatively small equipment pads. The stormwater management system includes infiltration basins that will promote groundwater recharge onsite. As a result, annual recharge from the post-development site will approximate the annual recharge from the site under pre-development conditions.
STANDARD 4:
Stormwater management systems shall be designed to remove 80% of the average annual post-construction load of Total Suspended Solids (TSS).
4
CEC Solar #1206, LLC Stormwater Management Report Hopkinton, Massachusetts 283600RP001
The project does not include proposed impervious surfaces requiring treatment, therefore the 80% TSS removal requirement does not apply. A Site Owner’s Manual has been developed to comply with the Long-Term Pollution Prevention Plan (Standard 4) and the Long-Term Operation and Maintenance Plan (Standard 9) requirements of the 2008 Massachusetts Department of Environmental Protection (MassDEP) Stormwater Management Standards. The Manual outlines source control and pollution prevention measures and maintenance requirements of stormwater BMPs associated with the proposed project.
STANDARD 5:
For land uses with higher potential pollutant loads (LUHPPLs), source control and pollution prevention shall be implemented in accordance with the Massachusetts Stormwater Handbook to eliminate or reduce the discharge of stormwater runoff from such land uses to the maximum extent practicable.
The proposed project is not associated with stormwater discharges from land uses with higher potential pollutant loads.
STANDARD 6:
Stormwater discharges to critical areas must utilize certain stormwater management BMPs approved for critical areas. Critical areas are Outstanding Resource Waters, shellfish beds, swimming beaches, coldwater fisheries and recharge areas for public water supplies.
The proposed BMPs are consistent with the Stormwater Management Handbook for use within the ORW critical area. Impervious areas requiring treatment are not proposed as part of this project.
STANDARD 7:
Redevelopment of previously developed sites must meet the Stormwater Management Standards to the maximum extent practicable. However, if it is not practicable to meet all the Standards, new (retrofitted or expanded) stormwater management systems must be designed to improve existing conditions.
The proposed project is new development, and therefore this standard does not apply.
5
CEC Solar #1206, LLC Stormwater Management Report Hopkinton, Massachusetts 283600RP001
STANDARD 8:
A plan to control construction-related impacts during erosion, sedimentation and other pollutant sources during construction and land disturbance activities (construction period erosion, sedimentation, and pollution prevention plan) shall be developed and implemented.
A draft Stormwater Pollution Prevention Plan (SWPPP) has been developed to comply with Section 3 of the NPDES Construction General Permit for Stormwater Discharges; therefore the requirements of Standard 8 are fulfilled.
STANDARD 9:
A Long-Term Operation and Maintenance (O&M) Plan shall be developed and implemented to ensure that stormwater management systems function as designed.
The Site Owner’s Manual complies with the Long-Term Pollution Prevention Plan (Standard 4) and the Long-Term Operation and Maintenance Plan (Standard 9) requirements of the 2008 Massachusetts Department of Environmental Protection (MassDEP) Stormwater Management Standards. The Manual outlines source control and pollution prevention measures and maintenance requirements of the stormwater BMPs associated with the proposed development.
STANDARD 10:
All illicit discharges to the stormwater management system are prohibited.
There will be no illicit discharges to the proposed stormwater management system associated with the proposed project. An Illicit Discharge Compliance Statement is provided on the following page.
3.5
Illicit Discharge Compliance Statement
6
CEC Solar #1206, LLC Stormwater Management Report Hopkinton, Massachusetts 283600RP001
An illicit discharge is any discharge to a municipal separate storm sewer that is not comprised entirely of stormwater, discharges from fire-fighting activities, and certain non-designated non-stormwater discharges. To the best of my knowledge, no detectable illicit discharge exists on site. The site plans included with this report detail the storm sewers that convey stormwater on the site and demonstrate that these systems do not include the entry of an illicit discharge. A Site Owner’s Manual is also included, which contains the Long Term Pollution Plan that outlines measures to prevent future illicit discharges. As the Site Owner, I will ultimately be responsible for implementing the Long Term Pollution Prevention Plan.
Signature:
_______________________________________ Owner’s Name
DEP’s Checklist for a Stormwater Report
7
Massachusetts Department of Environmental Protection Bureau of Resource Protection - Wetlands Program
Checklist for Stormwater Report A. Introduction Important: When filling out forms on the computer, use only the tab key to move your cursor - do not use the return key.
A Stormwater Report must be submitted with the Notice of Intent permit application to document compliance with the Stormwater Management Standards. The following checklist is NOT a substitute for the Stormwater Report (which should provide more substantive and detailed information) but is offered here as a tool to help the applicant organize their Stormwater Management documentation for their Report and for the reviewer to assess this information in a consistent format. As noted in the Checklist, the Stormwater Report must contain the engineering computations and supporting information set forth in Volume 3 of the Massachusetts Stormwater Handbook. The Stormwater Report must be prepared and certified by a Registered Professional Engineer (RPE) licensed in the Commonwealth. The Stormwater Report must include: • The Stormwater Checklist completed and stamped by a Registered Professional Engineer (see page 2) that certifies that the Stormwater Report contains all required submittals.1 This Checklist is to be used as the cover for the completed Stormwater Report. • Applicant/Project Name • Project Address • Name of Firm and Registered Professional Engineer that prepared the Report • Long-Term Pollution Prevention Plan required by Standards 4-6 • Construction Period Pollution Prevention and Erosion and Sedimentation Control Plan required by Standard 82 • Operation and Maintenance Plan required by Standard 9 In addition to all plans and supporting information, the Stormwater Report must include a brief narrative describing stormwater management practices, including environmentally sensitive site design and LID techniques, along with a diagram depicting runoff through the proposed BMP treatment train. Plans are required to show existing and proposed conditions, identify all wetland resource areas, NRCS soil types, critical areas, Land Uses with Higher Potential Pollutant Loads (LUHPPL), and any areas on the site where infiltration rate is greater than 2.4 inches per hour. The Plans shall identify the drainage areas for both existing and proposed conditions at a scale that enables verification of supporting calculations. As noted in the Checklist, the Stormwater Management Report shall document compliance with each of the Stormwater Management Standards as provided in the Massachusetts Stormwater Handbook. The soils evaluation and calculations shall be done using the methodologies set forth in Volume 3 of the Massachusetts Stormwater Handbook. To ensure that the Stormwater Report is complete, applicants are required to fill in the Stormwater Report Checklist by checking the box to indicate that the specified information has been included in the Stormwater Report. If any of the information specified in the checklist has not been submitted, the applicant must provide an explanation. The completed Stormwater Report Checklist and Certification must be submitted with the Stormwater Report.
1
The Stormwater Report may also include the Illicit Discharge Compliance Statement required by Standard 10. If not included in the Stormwater Report, the Illicit Discharge Compliance Statement must be submitted prior to the discharge of stormwater runoff to the post-construction best management practices. 2
For some complex projects, it may not be possible to include the Construction Period Erosion and Sedimentation Control Plan in the Stormwater Report. In that event, the issuing authority has the discretion to issue an Order of Conditions that approves the project and includes a condition requiring the proponent to submit the Construction Period Erosion and Sedimentation Control Plan before commencing any land disturbance activity on the site.
283600swcheck.doc • 04/01/08
Stormwater Report Checklist • Page 1 of 8
Massachusetts Department of Environmental Protection Bureau of Resource Protection - Wetlands Program
Checklist for Stormwater Report Checklist (continued) LID Measures: Stormwater Standards require LID measures to be considered. Document what environmentally sensitive design and LID Techniques were considered during the planning and design of the project: No disturbance to any Wetland Resource Areas Site Design Practices (e.g. clustered development, reduced frontage setbacks) Reduced Impervious Area (Redevelopment Only) Minimizing disturbance to existing trees and shrubs LID Site Design Credit Requested: Credit 1 Credit 2 Credit 3 Use of “country drainage” versus curb and gutter conveyance and pipe Bioretention Cells (includes Rain Gardens) Constructed Stormwater Wetlands (includes Gravel Wetlands designs) Treebox Filter Water Quality Swale Grass Channel Green Roof Other (describe):
Standard 1: No New Untreated Discharges No new untreated discharges Outlets have been designed so there is no erosion or scour to wetlands and waters of the Commonwealth Supporting calculations specified in Volume 3 of the Massachusetts Stormwater Handbook included.
283600swcheck.doc • 04/01/08
Stormwater Report Checklist • Page 3 of 8
Massachusetts Department of Environmental Protection Bureau of Resource Protection - Wetlands Program
Checklist for Stormwater Report Checklist (continued) Standard 2: Peak Rate Attenuation Standard 2 waiver requested because the project is located in land subject to coastal storm flowage and stormwater discharge is to a wetland subject to coastal flooding. Evaluation provided to determine whether off-site flooding increases during the 100-year 24-hour storm. Calculations provided to show that post-development peak discharge rates do not exceed predevelopment rates for the 2-year and 10-year 24-hour storms. If evaluation shows that off-site flooding increases during the 100-year 24-hour storm, calculations are also provided to show that post-development peak discharge rates do not exceed pre-development rates for the 100-year 24hour storm. Standard 3: Recharge Soil Analysis provided. Required Recharge Volume calculation provided. Required Recharge volume reduced through use of the LID site Design Credits. Sizing the infiltration, BMPs is based on the following method: Check the method used. Static
Simple Dynamic
Dynamic Field1
Runoff from all impervious areas at the site discharging to the infiltration BMP. Runoff from all impervious areas at the site is not discharging to the infiltration BMP and calculations are provided showing that the drainage area contributing runoff to the infiltration BMPs is sufficient to generate the required recharge volume. Recharge BMPs have been sized to infiltrate the Required Recharge Volume. Recharge BMPs have been sized to infiltrate the Required Recharge Volume only to the maximum extent practicable for the following reason: Site is comprised solely of C and D soils and/or bedrock at the land surface M.G.L. c. 21E sites pursuant to 310 CMR 40.0000 Solid Waste Landfill pursuant to 310 CMR 19.000 Project is otherwise subject to Stormwater Management Standards only to the maximum extent practicable. Calculations showing that the infiltration BMPs will drain in 72 hours are provided. Property includes a M.G.L. c. 21E site or a solid waste landfill and a mounding analysis is included.
1
80% TSS removal is required prior to discharge to infiltration BMP if Dynamic Field method is used.
283600swcheck.doc • 04/01/08
Stormwater Report Checklist • Page 4 of 8
Massachusetts Department of Environmental Protection Bureau of Resource Protection - Wetlands Program
Checklist for Stormwater Report Checklist (continued) Standard 3: Recharge (continued) The infiltration BMP is used to attenuate peak flows during storms greater than or equal to the 10year 24-hour storm and separation to seasonal high groundwater is less than 4 feet and a mounding analysis is provided. Documentation is provided showing that infiltration BMPs do not adversely impact nearby wetland resource areas. Standard 4: Water Quality The Long-Term Pollution Prevention Plan typically includes the following: • Good housekeeping practices; • Provisions for storing materials and waste products inside or under cover; • Vehicle washing controls; • Requirements for routine inspections and maintenance of stormwater BMPs; • Spill prevention and response plans; • Provisions for maintenance of lawns, gardens, and other landscaped areas; • Requirements for storage and use of fertilizers, herbicides, and pesticides; • Pet waste management provisions; • Provisions for operation and management of septic systems; • Provisions for solid waste management; • Snow disposal and plowing plans relative to Wetland Resource Areas; • Winter Road Salt and/or Sand Use and Storage restrictions; • Street sweeping schedules; • Provisions for prevention of illicit discharges to the stormwater management system; • Documentation that Stormwater BMPs are designed to provide for shutdown and containment in the event of a spill or discharges to or near critical areas or from LUHPPL; • Training for staff or personnel involved with implementing Long-Term Pollution Prevention Plan; • List of Emergency contacts for implementing Long-Term Pollution Prevention Plan. A Long-Term Pollution Prevention Plan is attached to Stormwater Report and is included as an attachment to the Wetlands Notice of Intent. Treatment BMPs subject to the 44% TSS removal pretreatment requirement and the one inch rule for calculating the water quality volume are included, and discharge: is within the Zone II or Interim Wellhead Protection Area is near or to other critical areas is within soils with a rapid infiltration rate (greater than 2.4 inches per hour) involves runoff from land uses with higher potential pollutant loads. The Required Water Quality Volume is reduced through use of the LID site Design Credits. Calculations documenting that the treatment train meets the 80% TSS removal requirement and, if applicable, the 44% TSS removal pretreatment requirement, are provided.
283600swcheck.doc • 04/01/08
Stormwater Report Checklist • Page 5 of 8
Massachusetts Department of Environmental Protection Bureau of Resource Protection - Wetlands Program
Checklist for Stormwater Report Checklist (continued) Standard 4: Water Quality (continued) The BMP is sized (and calculations provided) based on: The ½” or 1” Water Quality Volume or The equivalent flow rate associated with the Water Quality Volume and documentation is provided showing that the BMP treats the required water quality volume. The applicant proposes to use proprietary BMPs, and documentation supporting use of proprietary BMP and proposed TSS removal rate is provided. This documentation may be in the form of the propriety BMP checklist found in Volume 2, Chapter 4 of the Massachusetts Stormwater Handbook and submitting copies of the TARP Report, STEP Report, and/or other third party studies verifying performance of the proprietary BMPs. A TMDL exists that indicates a need to reduce pollutants other than TSS and documentation showing that the BMPs selected are consistent with the TMDL is provided. Standard 5: Land Uses With Higher Potential Pollutant Loads (LUHPPLs) The NPDES Multi-Sector General Permit covers the land use and the Stormwater Pollution Prevention Plan (SWPPP) has been included with the Stormwater Report. The NPDES Multi-Sector General Permit covers the land use and the SWPPP will be submitted prior to the discharge of stormwater to the post-construction stormwater BMPs. The NPDES Multi-Sector General Permit does not cover the land use. LUHPPLs are located at the site and industry specific source control and pollution prevention measures have been proposed to reduce or eliminate the exposure of LUHPPLs to rain, snow, snow melt and runoff, and been included in the long term Pollution Prevention Plan. All exposure has been eliminated. All exposure has not been eliminated and all BMPs selected are on MassDEP LUHPPL list. The LUHPPL has the potential to generate runoff with moderate to higher concentrations of oil and grease (e.g. all parking lots with >1000 vehicle trips per day) and the treatment train includes an oil grit separator, a filtering bioretention area, a sand filter or equivalent. Standard 6: Critical Areas The discharge is near or to a critical area and the treatment train includes only BMPs that MassDEP has approved for stormwater discharges to or near that particular class of critical area. Critical areas and BMPs are identified in the Stormwater Report.
283600swcheck.doc • 04/01/08
Stormwater Report Checklist • Page 6 of 8
Massachusetts Department of Environmental Protection Bureau of Resource Protection - Wetlands Program
Checklist for Stormwater Report Checklist (continued) Standard 7: Redevelopments and Other Projects Subject to the Standards only to the maximum extent practicable The project is subject to the Stormwater Management Standards only to the maximum Extent Practicable as a: Limited Project Small Residential Projects: 5-9 single family houses or 5-9 units in a multi-family development provided there is no discharge that may potentially affect a critical area. Small Residential Projects: 2-4 single family houses or 2-4 units in a multi-family development with a discharge to a critical area Marina and/or boatyard provided the hull painting, service and maintenance areas are protected from exposure to rain, snow, snow melt and runoff Bike Path and/or Foot Path Redevelopment Project Redevelopment portion of mix of new and redevelopment. Certain standards are not fully met (Standard No. 1, 8, 9, and 10 must always be fully met) and an explanation of why these standards are not met is contained in the Stormwater Report. The project involves redevelopment and a description of all measures that have been taken to improve existing conditions is provided in the Stormwater Report. The redevelopment checklist found in Volume 2 Chapter 3 of the Massachusetts Stormwater Handbook may be used to document that the proposed stormwater management system (a) complies with Standards 2, 3 and the pretreatment and structural BMP requirements of Standards 4-6 to the maximum extent practicable and (b) improves existing conditions. Standard 8: Construction Period Pollution Prevention and Erosion and Sedimentation Control A Construction Period Pollution Prevention and Erosion and Sedimentation Control Plan must include the following information: • • • • • • • • • • • • • •
Narrative; Construction Period Operation and Maintenance Plan; Names of Persons or Entity Responsible for Plan Compliance; Construction Period Pollution Prevention Measures; Erosion and Sedimentation Control Plan Drawings; Detail drawings and specifications for erosion control BMPs, including sizing calculations; Vegetation Planning; Site Development Plan; Construction Sequencing Plan; Sequencing of Erosion and Sedimentation Controls; Operation and Maintenance of Erosion and Sedimentation Controls; Inspection Schedule; Maintenance Schedule; Inspection and Maintenance Log Form.
A Construction Period Pollution Prevention and Erosion and Sedimentation Control Plan containing the information set forth above has been included in the Stormwater Report.
283600swcheck.doc • 04/01/08
Stormwater Report Checklist • Page 7 of 8
Massachusetts Department of Environmental Protection Bureau of Resource Protection - Wetlands Program
Checklist for Stormwater Report Checklist (continued) Standard 8: Construction Period Pollution Prevention and Erosion and Sedimentation Control (continued) The project is highly complex and information is included in the Stormwater Report that explains why it is not possible to submit the Construction Period Pollution Prevention and Erosion and Sedimentation Control Plan with the application. A Construction Period Pollution Prevention and Erosion and Sedimentation Control has not been included in the Stormwater Report but will be submitted before land disturbance begins. The project is not covered by a NPDES Construction General Permit. The project is covered by a NPDES Construction General Permit and a copy of the SWPPP is in the Stormwater Report. The project is covered by a NPDES Construction General Permit but no SWPPP been submitted. The SWPPP will be submitted BEFORE land disturbance begins. Standard 9: Operation and Maintenance Plan The Post Construction Operation and Maintenance Plan is included in the Stormwater Report and includes the following information: Name of the stormwater management system owners; Party responsible for operation and maintenance; Schedule for implementation of routine and non-routine maintenance tasks; Plan showing the location of all stormwater BMPs maintenance access areas; Description and delineation of public safety features; Estimated operation and maintenance budget; and Operation and Maintenance Log Form. The responsible party is not the owner of the parcel where the BMP is located and the Stormwater Report includes the following submissions: A copy of the legal instrument (deed, homeowner’s association, utility trust or other legal entity) that establishes the terms of and legal responsibility for the operation and maintenance of the project site stormwater BMPs; A plan and easement deed that allows site access for the legal entity to operate and maintain BMP functions. Standard 10: Prohibition of Illicit Discharges The Long-Term Pollution Prevention Plan includes measures to prevent illicit discharges; An Illicit Discharge Compliance Statement is attached; NO Illicit Discharge Compliance Statement is attached but will be submitted prior to the discharge of any stormwater to post-construction BMPs.
283600swcheck.doc • 04/01/08
Stormwater Report Checklist • Page 8 of 8
Appendix A Soil Data
290600
290700
290800
290900
291000
291100
291200
291300
291400
291500
291600 4676200
290500
71° 31' 26'' W
71° 32' 16'' W
Hydrologic Soil Group—Middlesex County, Massachusetts (2836.00)
42° 12' 37'' N
4674800
4674800
4674900
4674900
4675000
4675000
4675100
4675100
4675200
4675200
4675300
4675300
4675400
4675400
4675500
4675500
4675600
4675600
4675700
4675700
4675800
4675800
4675900
4675900
4676000
4676000
4676100
4676100
4676200
42° 12' 37'' N
4674700
Soil Map may not be valid at this scale.
42° 11' 47'' N
290600
290700
290800
290900
291000
291100
291200
Map Scale: 1:7,480 if printed on A portrait (8.5" x 11") sheet.
N
Meters 600 Feet 0 350 700 1400 2100 Map projection: Web Mercator Corner coordinates: WGS84 Edge tics: UTM Zone 19N WGS84 0
100
Natural Resources Conservation Service
200
400
Web Soil Survey National Cooperative Soil Survey
291300
291400
291500
291600 71° 31' 26'' W
71° 32' 16'' W
290500
1/6/2017 Page 1 of 5
42° 11' 47'' N
Hydrologic Soil Group—Middlesex County, Massachusetts (2836.00)
MAP LEGEND Area of Interest (AOI) Area of Interest (AOI) Soils Soil Rating Polygons A A/D B B/D C C/D D Not rated or not available Soil Rating Lines A
MAP INFORMATION The soil surveys that comprise your AOI were mapped at 1:25,000.
C C/D D
Warning: Soil Map may not be valid at this scale.
Not rated or not available
Enlargement of maps beyond the scale of mapping can cause misunderstanding of the detail of mapping and accuracy of soil line placement. The maps do not show the small areas of contrasting soils that could have been shown at a more detailed scale.
Water Features Streams and Canals Transportation Rails Interstate Highways US Routes Major Roads Local Roads Background Aerial Photography
A/D B
Please rely on the bar scale on each map sheet for map measurements. Source of Map: Natural Resources Conservation Service Web Soil Survey URL: Coordinate System: Web Mercator (EPSG:3857) Maps from the Web Soil Survey are based on the Web Mercator projection, which preserves direction and shape but distorts distance and area. A projection that preserves area, such as the Albers equal-area conic projection, should be used if more accurate calculations of distance or area are required. This product is generated from the USDA-NRCS certified data as of the version date(s) listed below.
B/D
Soil Survey Area: Middlesex County, Massachusetts Survey Area Data: Version 16, Sep 14, 2016
C C/D
Soil map units are labeled (as space allows) for map scales 1:50,000 or larger.
D
Date(s) aerial images were photographed: 28, 2014
Not rated or not available Soil Rating Points
Sep 12, 2014—Sep
The orthophoto or other base map on which the soil lines were compiled and digitized probably differs from the background imagery displayed on these maps. As a result, some minor shifting of map unit boundaries may be evident.
A A/D B B/D
Natural Resources Conservation Service
Web Soil Survey National Cooperative Soil Survey
1/6/2017 Page 2 of 5
Hydrologic Soil Group—Middlesex County, Massachusetts
2836.00
Hydrologic Soil Group
Hydrologic Soil Group— Summary by Map Unit — Middlesex County, Massachusetts (MA017) Map unit symbol
Map unit name
Rating
51A
Swansea muck, 0 to 1 percent slopes
B/D
71B
Ridgebury fine sandy loam, 3 to 8 percent slopes, extremely stony
73B
Acres in AOI
Percent of AOI 4.2
1.6%
D
20.6
7.9%
Whitman fine sandy loam, 0 to 3 percent slopes, extremely stony
D
27.3
10.5%
106C
Narragansett-HollisRock outcrop complex, 3 to 15 percent slopes
A
9.9
3.8%
302B
Montauk fine sandy loam, 0 to 8 percent slopes, extremely stony
C
0.4
0.1%
302D
Montauk fine sandy C loam, 15 to 35 percent slopes, extremely stony
5.0
1.9%
307B
Paxton fine sandy loam, C 0 to 8 percent slopes, extremely stony
15.2
5.9%
307C
Paxton fine sandy loam, C 8 to 15 percent slopes, extremely stony
1.7
0.6%
317B
Scituate fine sandy loam, 3 to 8 percent slopes, extremely stony
11.7
4.5%
336B
Rainbow silt loam, 3 to 8 C/D percent slopes, very stony
1.6
0.6%
416B
Narragansett silt loam, 3 A to 8 percent slopes, very stony
31.9
12.3%
416C
Narragansett silt loam, 8 A to 15 percent slopes, very stony
56.9
21.9%
422B
Canton fine sandy loam, B 0 to 8 percent slopes, extremely stony
41.3
15.9%
Natural Resources Conservation Service
D
Web Soil Survey National Cooperative Soil Survey
1/6/2017 Page 3 of 5
Hydrologic Soil Group—Middlesex County, Massachusetts
2836.00
Hydrologic Soil Group— Summary by Map Unit — Middlesex County, Massachusetts (MA017) Map unit symbol
Map unit name
Rating
Acres in AOI
Percent of AOI
424B
Canton fine sandy loam, A 3 to 8 percent slopes, extremely bouldery
16.8
6.5%
424C
Canton fine sandy loam, A 8 to 15 percent slopes, extremely bouldery
8.3
3.2%
424D
Canton fine sandy loam, A 15 to 25 percent slopes, extremely bouldery
6.9
2.7%
654
Udorthents, loamy
0.1
0.0%
259.7
100.0%
Totals for Area of Interest
Description Hydrologic soil groups are based on estimates of runoff potential. Soils are assigned to one of four groups according to the rate of water infiltration when the soils are not protected by vegetation, are thoroughly wet, and receive precipitation from long-duration storms. The soils in the United States are assigned to four groups (A, B, C, and D) and three dual classes (A/D, B/D, and C/D). The groups are defined as follows: Group A. Soils having a high infiltration rate (low runoff potential) when thoroughly wet. These consist mainly of deep, well drained to excessively drained sands or gravelly sands. These soils have a high rate of water transmission. Group B. Soils having a moderate infiltration rate when thoroughly wet. These consist chiefly of moderately deep or deep, moderately well drained or well drained soils that have moderately fine texture to moderately coarse texture. These soils have a moderate rate of water transmission. Group C. Soils having a slow infiltration rate when thoroughly wet. These consist chiefly of soils having a layer that impedes the downward movement of water or soils of moderately fine texture or fine texture. These soils have a slow rate of water transmission. Group D. Soils having a very slow infiltration rate (high runoff potential) when thoroughly wet. These consist chiefly of clays that have a high shrink-swell potential, soils that have a high water table, soils that have a claypan or clay layer at or near the surface, and soils that are shallow over nearly impervious material. These soils have a very slow rate of water transmission. If a soil is assigned to a dual hydrologic group (A/D, B/D, or C/D), the first letter is for drained areas and the second is for undrained areas. Only the soils that in their natural condition are in group D are assigned to dual classes.
Natural Resources Conservation Service
Web Soil Survey National Cooperative Soil Survey
1/6/2017 Page 4 of 5
Appendix B Pre-Development Hydrologic Analysis
Extreme Precipitation Tables: 42.201°N, 71.531°W
Page 1 of 1
Extreme Precipitation Tables Northeast Regional Climate Center Data represents point estimates calculated from partial duration series. All precipitation amounts are displayed in inches. Smoothing State Location Longitude Latitude Elevation Date/Time
Yes Massachusetts 71.531 degrees West 42.201 degrees North 0 feet Thu, 23 Mar 2017 17:26:16 -0400
Extreme Precipitation Estimates 1yr 2yr 5yr 10yr 25yr 50yr 100yr 200yr 500yr
5min 0.29 0.35 0.42 0.47 0.56 0.63 0.72 0.82 0.99
10min 0.44 0.54 0.65 0.74 0.89 1.01 1.17 1.34 1.63
15min 0.54 0.67 0.81 0.93 1.13 1.29 1.51 1.74 2.13
30min 0.71 0.89 1.09 1.27 1.55 1.81 2.13 2.49 3.09
60min 120min 1hr 2hr 3hr 6hr 12hr 24hr 48hr 0.89 1.13 1yr 0.77 1.07 1.31 1.65 2.10 2.68 2.92 1yr 1.11 1.40 2yr 0.96 1.29 1.63 2.04 2.57 3.23 3.52 2yr 1.39 1.77 5yr 1.20 1.61 2.06 2.59 3.24 4.06 4.48 5yr 1.65 2.11 10yr 1.42 1.90 2.46 3.10 3.88 4.84 5.38 10yr 2.06 2.66 25yr 1.78 2.36 3.11 3.93 4.91 6.09 6.87 25yr 2.44 3.19 50yr 2.11 2.79 3.74 4.72 5.88 7.26 8.26 50yr 2.90 3.80 100yr 2.50 3.30 4.47 5.64 7.02 8.66 9.95 100yr 3.44 4.54 200yr 2.97 3.90 5.35 6.76 8.40 10.32 11.98 200yr 4.32 5.75 500yr 3.73 4.87 6.79 8.58 10.65 13.04 15.32 500yr
1day 2.37 2.86 3.59 4.28 5.39 6.42 7.66 9.14 11.54
2day 2.81 3.38 4.31 5.18 6.60 7.95 9.56 11.52 14.73
4day 3.25 3.89 4.93 5.91 7.50 8.99 10.79 12.94 16.47
7day 3.92 4.62 5.83 6.95 8.78 10.47 12.50 14.93 18.89
10day 4.56 5.25 6.52 7.68 9.54 11.26 13.28 15.67 19.51
1yr 2yr 5yr 10yr 25yr 50yr 100yr 200yr 500yr
Lower Confidence Limits 1yr 2yr 5yr 10yr 25yr 50yr 100yr 200yr 500yr
5min 0.23 0.34 0.38 0.42 0.49 0.54 0.59 0.66 0.75
10min 0.35 0.53 0.59 0.65 0.74 0.82 0.90 0.99 1.12
15min 0.43 0.65 0.73 0.81 0.92 1.02 1.13 1.25 1.44
30min 0.58 0.88 1.00 1.13 1.31 1.46 1.63 1.81 2.09
60min 120min 1hr 2hr 3hr 6hr 12hr 24hr 48hr 0.71 0.94 1yr 0.61 0.92 1.07 1.42 1.85 2.35 2.70 1yr 1.08 1.27 2yr 0.93 1.24 1.45 1.91 2.44 3.13 3.40 2yr 1.28 1.52 5yr 1.10 1.48 1.72 2.25 2.86 3.73 4.12 5yr 1.45 1.73 10yr 1.26 1.69 1.95 2.55 3.22 4.27 4.76 10yr 1.73 2.05 25yr 1.49 2.01 2.31 3.02 3.78 5.11 5.72 25yr 1.97 2.33 50yr 1.70 2.28 2.62 3.42 4.26 5.85 6.59 50yr 2.23 2.65 100yr 1.93 2.59 2.97 3.88 4.81 6.71 7.57 100yr 2.53 3.02 200yr 2.18 2.96 3.38 4.42 5.44 7.70 8.68 200yr 2.97 3.60 500yr 2.56 3.52 3.99 5.25 6.42 9.26 10.39 500yr
1day 2.08 2.77 3.31 3.78 4.53 5.18 5.94 6.81 8.19
2day 2.60 3.27 3.97 4.57 5.50 6.34 7.28 8.35 9.99
4day 2.95 3.76 4.54 5.24 6.34 7.33 8.48 9.80 11.90
7day 3.58 4.46 5.36 6.14 7.36 8.43 9.70 11.14 13.38
10day 4.11 5.08 6.02 6.84 8.07 9.18 10.44 11.89 14.14
1yr 2yr 5yr 10yr 25yr 50yr 100yr 200yr 500yr
Upper Confidence Limits 1yr 2yr 5yr 10yr 25yr 50yr 100yr 200yr 500yr
5min 0.32 0.37 0.45 0.54 0.69 0.82 0.99 1.19 1.55
10min 0.49 0.56 0.70 0.83 1.04 1.25 1.50 1.80 2.30
15min 0.60 0.69 0.87 1.03 1.30 1.56 1.88 2.28 2.96
30min 0.81 0.94 1.19 1.44 1.86 2.24 2.71 3.30 4.30
60min 120min 1hr 2hr 3hr 6hr 12hr 24hr 48hr 1.00 1.19 1yr 0.86 1.17 1.37 1.76 2.30 2.93 3.16 1yr 1.16 1.36 2yr 1.00 1.33 1.57 2.04 2.60 3.36 3.66 2yr 1.51 1.78 5yr 1.31 1.74 2.04 2.62 3.31 4.39 4.86 5yr 1.86 2.19 10yr 1.60 2.14 2.50 3.18 3.96 5.39 6.06 10yr 2.44 2.88 25yr 2.11 2.82 3.27 4.08 5.05 7.07 8.12 25yr 3.01 3.54 50yr 2.60 3.46 4.02 4.94 6.06 8.69 10.12 50yr 3.72 4.36 100yr 3.21 4.26 4.93 5.98 7.28 10.67 12.66 100yr 4.60 5.37 200yr 3.97 5.25 6.07 7.24 8.73 13.10 15.85 200yr 6.11 7.08 500yr 5.28 6.92 7.98 9.32 11.12 17.21 21.36 500yr
1day 2.60 2.97 3.89 4.77 6.26 7.69 9.44 11.59 15.23
2day 3.04 3.52 4.67 5.83 7.80 9.73 12.18 15.24 20.54
4day 3.53 4.05 5.37 6.65 8.85 10.98 13.64 16.93 22.55
7day 4.23 4.80 6.35 7.84 10.39 12.84 15.88 19.65 26.05
10day 4.89 5.44 7.04 8.58 11.15 13.62 16.61 20.23 26.30
1yr 2yr 5yr 10yr 25yr 50yr 100yr 200yr 500yr
Powered by ACIS
file:///G:/Projdata/2836/Transfers/In/NRCC/2017-03-23/output.htm
4/24/2017
Hydrologic Soil Group—Middlesex County, Massachusetts
2836.00
Rating Options Aggregation Method: Dominant Condition Component Percent Cutoff: None Specified Tie-break Rule: Higher
Natural Resources Conservation Service
Web Soil Survey National Cooperative Soil Survey
1/6/2017 Page 5 of 5
10R 1S E-DP-1 E-DA-1
2S 30R
3S
E-DP-3
E-DA-3
E-DA-2
20R E-DP-2
PRE-DEVELOPMENT
Subcat
Reach
Pond
Link
Routing Diagram for 283600HC001A Prepared by Microsoft, Printed 4/24/2017 HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
2836.00 Pre-Development
283600HC001A Prepared by Microsoft HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Area Listing (selected nodes) Area (acres)
CN
0.081 2.223 0.021 0.077 0.349 0.066 0.127 11.144 9.228 0.256 23.572
39 61 80 98 98 98 98 30 55 77 45
Description (subcatchment-numbers) >75% Grass cover, Good, HSG A (3S) >75% Grass cover, Good, HSG B (2S, 3S) >75% Grass cover, Good, HSG D (3S) Paved parking, HSG A (3S) Paved parking, HSG B (2S, 3S) Paved parking, HSG D (2S, 3S) Unconnected roofs, HSG B (2S, 3S) Woods, Good, HSG A (1S, 2S, 3S) Woods, Good, HSG B (1S, 2S, 3S) Woods, Good, HSG D (1S, 2S, 3S) TOTAL AREA
Printed 4/24/2017 Page 2
2836.00 Pre-Development
283600HC001A Prepared by Microsoft HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Soil Listing (selected nodes) Area (acres)
Soil Group
Subcatchment Numbers
11.302 11.927 0.000 0.343 0.000 23.572
HSG A HSG B HSG C HSG D Other
1S, 2S, 3S 1S, 2S, 3S 1S, 2S, 3S TOTAL AREA
Printed 4/24/2017 Page 3
2836.00 Pre-Development
283600HC001A Printed 4/24/2017 Page 4
Prepared by Microsoft HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Ground Covers (selected nodes) HSG-A (acres)
HSG-B (acres)
HSG-C (acres)
HSG-D (acres)
Other (acres)
Total (acres)
Ground Cover
Subcatchment Numbers
0.081 0.077 0.000 11.144
2.223 0.349 0.127 9.228
0.000 0.000 0.000 0.000
0.021 0.066 0.000 0.256
0.000 0.000 0.000 0.000
2.325 0.492 0.127 20.628
>75% Grass cover, Good Paved parking Unconnected roofs Woods, Good
2S, 3S 2S, 3S 2S, 3S 1S, 2S, 3S
11.302
11.927
0.000
0.343
0.000
23.572
TOTAL AREA
2836.00 Pre-Development
Type III 24-hr 2-YR NRCC Rainfall=3.22"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Printed 4/24/2017 Page 5
Summary for Subcatchment 1S: E-DA-1 [45] Hint: Runoff=Zero Runoff
=
0.00 cfs @
0.00 hrs, Volume=
0.000 af, Depth= 0.00"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 2-YR NRCC Rainfall=3.22" Area (ac) 7.407 1.544 0.001 8.952 8.952
CN 30 55 77 34
Description Woods, Good, HSG A Woods, Good, HSG B Woods, Good, HSG D Weighted Average 100.00% Pervious Area
Tc Length Slope (min) (feet) (ft/ft) 13.0 50 0.0690
Velocity (ft/sec) 0.06
11.9
272
0.0231
0.38
6.4
308
0.1045
0.81
31.3
630
Total
Capacity (cfs)
Description Sheet Flow, Sheet Flow Woods: Dense underbrush n= 0.800 P2= 3.23" Shallow Concentrated Flow, Shallow Concentrated Flow 1 Forest w/Heavy Litter Kv= 2.5 fps Shallow Concentrated Flow, Shallow Concentrated Flow 2 Forest w/Heavy Litter Kv= 2.5 fps
Summary for Subcatchment 2S: E-DA-2 Runoff
=
0.22 cfs @ 12.95 hrs, Volume=
0.093 af, Depth> 0.17"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 2-YR NRCC Rainfall=3.22" Area (ac) 0.105 0.053 0.056 1.417 3.482 0.057 1.229 6.399 6.185 0.214 0.056
CN 98 98 98 30 55 77 61 52
Description Paved parking, HSG B Paved parking, HSG D Unconnected roofs, HSG B Woods, Good, HSG A Woods, Good, HSG B Woods, Good, HSG D >75% Grass cover, Good, HSG B Weighted Average 96.66% Pervious Area 3.34% Impervious Area 26.17% Unconnected
2836.00 Pre-Development
Type III 24-hr 2-YR NRCC Rainfall=3.22"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Tc Length Slope (min) (feet) (ft/ft) 15.5 50 0.0450
Velocity (ft/sec) 0.05
13.2
299
0.0229
0.38
3.6
168
0.0954
0.77
5.8
165
0.0364
0.48
38.1
682
Total
Capacity (cfs)
Printed 4/24/2017 Page 6
Description Sheet Flow, Sheet Flow Woods: Dense underbrush n= 0.800 P2= 3.23" Shallow Concentrated Flow, Shallow Concentrated Flow 1 Forest w/Heavy Litter Kv= 2.5 fps Shallow Concentrated Flow, Shallow Concentrated Flow 2 Forest w/Heavy Litter Kv= 2.5 fps Shallow Concentrated Flow, Shallow Concentrated Flow 3 Forest w/Heavy Litter Kv= 2.5 fps
Summary for Subcatchment 3S: E-DA-3 Runoff
=
0.22 cfs @ 12.97 hrs, Volume=
0.104 af, Depth> 0.15"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 2-YR NRCC Rainfall=3.22" Area (ac) 0.077 0.244 0.013 0.071 2.320 4.202 0.198 0.081 0.994 0.021 8.221 7.816 0.405 0.071
CN 98 98 98 98 30 55 77 39 61 80 51
Description Paved parking, HSG A Paved parking, HSG B Paved parking, HSG D Unconnected roofs, HSG B Woods, Good, HSG A Woods, Good, HSG B Woods, Good, HSG D >75% Grass cover, Good, HSG A >75% Grass cover, Good, HSG B >75% Grass cover, Good, HSG D Weighted Average 95.07% Pervious Area 4.93% Impervious Area 17.53% Unconnected
Tc Length Slope (min) (feet) (ft/ft) 14.8 50 0.0500
Velocity (ft/sec) 0.06
12.1
347
0.0363
0.48
7.0
301
0.0830
0.72
33.9
698
Total
Capacity (cfs)
Description Sheet Flow, Sheet Flow Woods: Dense underbrush n= 0.800 P2= 3.23" Shallow Concentrated Flow, Shallow Concentrated Flow 1 Forest w/Heavy Litter Kv= 2.5 fps Shallow Concentrated Flow, Shallow Concentrated Flow 2 Forest w/Heavy Litter Kv= 2.5 fps
2836.00 Pre-Development
Type III 24-hr 2-YR NRCC Rainfall=3.22"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Printed 4/24/2017 Page 7
Summary for Reach 10R: E-DP-1 [40] Hint: Not Described (Outflow=Inflow) Inflow Area = Inflow = Outflow =
8.952 ac, 0.00% Impervious, Inflow Depth = 0.00" for 2-YR NRCC event 0.00 cfs @ 0.00 hrs, Volume= 0.000 af 0.00 cfs @ 0.00 hrs, Volume= 0.000 af, Atten= 0%, Lag= 0.0 min
Routing by Stor-Ind+Trans method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs
Summary for Reach 20R: E-DP-2 [40] Hint: Not Described (Outflow=Inflow) Inflow Area = Inflow = Outflow =
6.399 ac, 3.34% Impervious, Inflow Depth > 0.17" for 2-YR NRCC event 0.22 cfs @ 12.95 hrs, Volume= 0.093 af 0.22 cfs @ 12.95 hrs, Volume= 0.093 af, Atten= 0%, Lag= 0.0 min
Routing by Stor-Ind+Trans method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs
Summary for Reach 30R: E-DP-3 [40] Hint: Not Described (Outflow=Inflow) Inflow Area = Inflow = Outflow =
8.221 ac, 4.93% Impervious, Inflow Depth > 0.15" for 2-YR NRCC event 0.22 cfs @ 12.97 hrs, Volume= 0.104 af 0.22 cfs @ 12.97 hrs, Volume= 0.104 af, Atten= 0%, Lag= 0.0 min
Routing by Stor-Ind+Trans method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs
2836.00 Pre-Development
Type III 24-hr 10-YR NRCC Rainfall=4.81"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Printed 4/24/2017 Page 8
Summary for Subcatchment 1S: E-DA-1 Runoff
=
0.04 cfs @ 17.18 hrs, Volume=
0.030 af, Depth> 0.04"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 10-YR NRCC Rainfall=4.81" Area (ac) 7.407 1.544 0.001 8.952 8.952
CN 30 55 77 34
Description Woods, Good, HSG A Woods, Good, HSG B Woods, Good, HSG D Weighted Average 100.00% Pervious Area
Tc Length Slope (min) (feet) (ft/ft) 13.0 50 0.0690
Velocity (ft/sec) 0.06
11.9
272
0.0231
0.38
6.4
308
0.1045
0.81
31.3
630
Total
Capacity (cfs)
Description Sheet Flow, Sheet Flow Woods: Dense underbrush n= 0.800 P2= 3.23" Shallow Concentrated Flow, Shallow Concentrated Flow 1 Forest w/Heavy Litter Kv= 2.5 fps Shallow Concentrated Flow, Shallow Concentrated Flow 2 Forest w/Heavy Litter Kv= 2.5 fps
Summary for Subcatchment 2S: E-DA-2 Runoff
=
1.95 cfs @ 12.67 hrs, Volume=
0.379 af, Depth> 0.71"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 10-YR NRCC Rainfall=4.81" Area (ac) 0.105 0.053 0.056 1.417 3.482 0.057 1.229 6.399 6.185 0.214 0.056
CN 98 98 98 30 55 77 61 52
Description Paved parking, HSG B Paved parking, HSG D Unconnected roofs, HSG B Woods, Good, HSG A Woods, Good, HSG B Woods, Good, HSG D >75% Grass cover, Good, HSG B Weighted Average 96.66% Pervious Area 3.34% Impervious Area 26.17% Unconnected
2836.00 Pre-Development
Type III 24-hr 10-YR NRCC Rainfall=4.81"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Tc Length Slope (min) (feet) (ft/ft) 15.5 50 0.0450
Velocity (ft/sec) 0.05
13.2
299
0.0229
0.38
3.6
168
0.0954
0.77
5.8
165
0.0364
0.48
38.1
682
Total
Capacity (cfs)
Printed 4/24/2017 Page 9
Description Sheet Flow, Sheet Flow Woods: Dense underbrush n= 0.800 P2= 3.23" Shallow Concentrated Flow, Shallow Concentrated Flow 1 Forest w/Heavy Litter Kv= 2.5 fps Shallow Concentrated Flow, Shallow Concentrated Flow 2 Forest w/Heavy Litter Kv= 2.5 fps Shallow Concentrated Flow, Shallow Concentrated Flow 3 Forest w/Heavy Litter Kv= 2.5 fps
Summary for Subcatchment 3S: E-DA-3 Runoff
=
2.35 cfs @ 12.62 hrs, Volume=
0.451 af, Depth> 0.66"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 10-YR NRCC Rainfall=4.81" Area (ac) 0.077 0.244 0.013 0.071 2.320 4.202 0.198 0.081 0.994 0.021 8.221 7.816 0.405 0.071
CN 98 98 98 98 30 55 77 39 61 80 51
Description Paved parking, HSG A Paved parking, HSG B Paved parking, HSG D Unconnected roofs, HSG B Woods, Good, HSG A Woods, Good, HSG B Woods, Good, HSG D >75% Grass cover, Good, HSG A >75% Grass cover, Good, HSG B >75% Grass cover, Good, HSG D Weighted Average 95.07% Pervious Area 4.93% Impervious Area 17.53% Unconnected
Tc Length Slope (min) (feet) (ft/ft) 14.8 50 0.0500
Velocity (ft/sec) 0.06
12.1
347
0.0363
0.48
7.0
301
0.0830
0.72
33.9
698
Total
Capacity (cfs)
Description Sheet Flow, Sheet Flow Woods: Dense underbrush n= 0.800 P2= 3.23" Shallow Concentrated Flow, Shallow Concentrated Flow 1 Forest w/Heavy Litter Kv= 2.5 fps Shallow Concentrated Flow, Shallow Concentrated Flow 2 Forest w/Heavy Litter Kv= 2.5 fps
2836.00 Pre-Development
Type III 24-hr 10-YR NRCC Rainfall=4.81"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Printed 4/24/2017 Page 10
Summary for Reach 10R: E-DP-1 [40] Hint: Not Described (Outflow=Inflow) Inflow Area = Inflow = Outflow =
8.952 ac, 0.00% Impervious, Inflow Depth > 0.04" for 10-YR NRCC event 0.04 cfs @ 17.18 hrs, Volume= 0.030 af 0.04 cfs @ 17.18 hrs, Volume= 0.030 af, Atten= 0%, Lag= 0.0 min
Routing by Stor-Ind+Trans method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs
Summary for Reach 20R: E-DP-2 [40] Hint: Not Described (Outflow=Inflow) Inflow Area = Inflow = Outflow =
6.399 ac, 3.34% Impervious, Inflow Depth > 0.71" for 10-YR NRCC event 1.95 cfs @ 12.67 hrs, Volume= 0.379 af 1.95 cfs @ 12.67 hrs, Volume= 0.379 af, Atten= 0%, Lag= 0.0 min
Routing by Stor-Ind+Trans method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs
Summary for Reach 30R: E-DP-3 [40] Hint: Not Described (Outflow=Inflow) Inflow Area = Inflow = Outflow =
8.221 ac, 4.93% Impervious, Inflow Depth > 0.66" for 10-YR NRCC event 2.35 cfs @ 12.62 hrs, Volume= 0.451 af 2.35 cfs @ 12.62 hrs, Volume= 0.451 af, Atten= 0%, Lag= 0.0 min
Routing by Stor-Ind+Trans method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs
2836.00 Pre-Development
Type III 24-hr 25-YR NRCC Rainfall=6.05"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Printed 4/24/2017 Page 11
Summary for Subcatchment 1S: E-DA-1 Runoff
=
0.27 cfs @ 13.97 hrs, Volume=
0.159 af, Depth> 0.21"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 25-YR NRCC Rainfall=6.05" Area (ac) 7.407 1.544 0.001 8.952 8.952
CN 30 55 77 34
Description Woods, Good, HSG A Woods, Good, HSG B Woods, Good, HSG D Weighted Average 100.00% Pervious Area
Tc Length Slope (min) (feet) (ft/ft) 13.0 50 0.0690
Velocity (ft/sec) 0.06
11.9
272
0.0231
0.38
6.4
308
0.1045
0.81
31.3
630
Total
Capacity (cfs)
Description Sheet Flow, Sheet Flow Woods: Dense underbrush n= 0.800 P2= 3.23" Shallow Concentrated Flow, Shallow Concentrated Flow 1 Forest w/Heavy Litter Kv= 2.5 fps Shallow Concentrated Flow, Shallow Concentrated Flow 2 Forest w/Heavy Litter Kv= 2.5 fps
Summary for Subcatchment 2S: E-DA-2 Runoff
=
4.21 cfs @ 12.62 hrs, Volume=
0.693 af, Depth> 1.30"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 25-YR NRCC Rainfall=6.05" Area (ac) 0.105 0.053 0.056 1.417 3.482 0.057 1.229 6.399 6.185 0.214 0.056
CN 98 98 98 30 55 77 61 52
Description Paved parking, HSG B Paved parking, HSG D Unconnected roofs, HSG B Woods, Good, HSG A Woods, Good, HSG B Woods, Good, HSG D >75% Grass cover, Good, HSG B Weighted Average 96.66% Pervious Area 3.34% Impervious Area 26.17% Unconnected
2836.00 Pre-Development
Type III 24-hr 25-YR NRCC Rainfall=6.05"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Tc Length Slope (min) (feet) (ft/ft) 15.5 50 0.0450
Velocity (ft/sec) 0.05
13.2
299
0.0229
0.38
3.6
168
0.0954
0.77
5.8
165
0.0364
0.48
38.1
682
Total
Capacity (cfs)
Printed 4/24/2017 Page 12
Description Sheet Flow, Sheet Flow Woods: Dense underbrush n= 0.800 P2= 3.23" Shallow Concentrated Flow, Shallow Concentrated Flow 1 Forest w/Heavy Litter Kv= 2.5 fps Shallow Concentrated Flow, Shallow Concentrated Flow 2 Forest w/Heavy Litter Kv= 2.5 fps Shallow Concentrated Flow, Shallow Concentrated Flow 3 Forest w/Heavy Litter Kv= 2.5 fps
Summary for Subcatchment 3S: E-DA-3 Runoff
=
5.29 cfs @ 12.56 hrs, Volume=
0.841 af, Depth> 1.23"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 25-YR NRCC Rainfall=6.05" Area (ac) 0.077 0.244 0.013 0.071 2.320 4.202 0.198 0.081 0.994 0.021 8.221 7.816 0.405 0.071
CN 98 98 98 98 30 55 77 39 61 80 51
Description Paved parking, HSG A Paved parking, HSG B Paved parking, HSG D Unconnected roofs, HSG B Woods, Good, HSG A Woods, Good, HSG B Woods, Good, HSG D >75% Grass cover, Good, HSG A >75% Grass cover, Good, HSG B >75% Grass cover, Good, HSG D Weighted Average 95.07% Pervious Area 4.93% Impervious Area 17.53% Unconnected
Tc Length Slope (min) (feet) (ft/ft) 14.8 50 0.0500
Velocity (ft/sec) 0.06
12.1
347
0.0363
0.48
7.0
301
0.0830
0.72
33.9
698
Total
Capacity (cfs)
Description Sheet Flow, Sheet Flow Woods: Dense underbrush n= 0.800 P2= 3.23" Shallow Concentrated Flow, Shallow Concentrated Flow 1 Forest w/Heavy Litter Kv= 2.5 fps Shallow Concentrated Flow, Shallow Concentrated Flow 2 Forest w/Heavy Litter Kv= 2.5 fps
2836.00 Pre-Development
Type III 24-hr 25-YR NRCC Rainfall=6.05"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Printed 4/24/2017 Page 13
Summary for Reach 10R: E-DP-1 [40] Hint: Not Described (Outflow=Inflow) Inflow Area = Inflow = Outflow =
8.952 ac, 0.00% Impervious, Inflow Depth > 0.21" for 25-YR NRCC event 0.27 cfs @ 13.97 hrs, Volume= 0.159 af 0.27 cfs @ 13.97 hrs, Volume= 0.159 af, Atten= 0%, Lag= 0.0 min
Routing by Stor-Ind+Trans method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs
Summary for Reach 20R: E-DP-2 [40] Hint: Not Described (Outflow=Inflow) Inflow Area = Inflow = Outflow =
6.399 ac, 3.34% Impervious, Inflow Depth > 1.30" for 25-YR NRCC event 4.21 cfs @ 12.62 hrs, Volume= 0.693 af 4.21 cfs @ 12.62 hrs, Volume= 0.693 af, Atten= 0%, Lag= 0.0 min
Routing by Stor-Ind+Trans method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs
Summary for Reach 30R: E-DP-3 [40] Hint: Not Described (Outflow=Inflow) Inflow Area = Inflow = Outflow =
8.221 ac, 4.93% Impervious, Inflow Depth > 1.23" for 25-YR NRCC event 5.29 cfs @ 12.56 hrs, Volume= 0.841 af 5.29 cfs @ 12.56 hrs, Volume= 0.841 af, Atten= 0%, Lag= 0.0 min
Routing by Stor-Ind+Trans method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs
2836.00 Pre-Development
Type III 24-hr 100-YR NRCC Rainfall=8.59"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Printed 4/24/2017 Page 14
Summary for Subcatchment 1S: E-DA-1 Runoff
=
3.08 cfs @ 12.64 hrs, Volume=
0.676 af, Depth> 0.91"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 100-YR NRCC Rainfall=8.59" Area (ac) 7.407 1.544 0.001 8.952 8.952
CN 30 55 77 34
Description Woods, Good, HSG A Woods, Good, HSG B Woods, Good, HSG D Weighted Average 100.00% Pervious Area
Tc Length Slope (min) (feet) (ft/ft) 13.0 50 0.0690
Velocity (ft/sec) 0.06
11.9
272
0.0231
0.38
6.4
308
0.1045
0.81
31.3
630
Total
Capacity (cfs)
Description Sheet Flow, Sheet Flow Woods: Dense underbrush n= 0.800 P2= 3.23" Shallow Concentrated Flow, Shallow Concentrated Flow 1 Forest w/Heavy Litter Kv= 2.5 fps Shallow Concentrated Flow, Shallow Concentrated Flow 2 Forest w/Heavy Litter Kv= 2.5 fps
Summary for Subcatchment 2S: E-DA-2 Runoff
=
10.21 cfs @ 12.57 hrs, Volume=
1.503 af, Depth> 2.82"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 100-YR NRCC Rainfall=8.59" Area (ac) 0.105 0.053 0.056 1.417 3.482 0.057 1.229 6.399 6.185 0.214 0.056
CN 98 98 98 30 55 77 61 52
Description Paved parking, HSG B Paved parking, HSG D Unconnected roofs, HSG B Woods, Good, HSG A Woods, Good, HSG B Woods, Good, HSG D >75% Grass cover, Good, HSG B Weighted Average 96.66% Pervious Area 3.34% Impervious Area 26.17% Unconnected
2836.00 Pre-Development
Type III 24-hr 100-YR NRCC Rainfall=8.59"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Tc Length Slope (min) (feet) (ft/ft) 15.5 50 0.0450
Velocity (ft/sec) 0.05
13.2
299
0.0229
0.38
3.6
168
0.0954
0.77
5.8
165
0.0364
0.48
38.1
682
Total
Capacity (cfs)
Printed 4/24/2017 Page 15
Description Sheet Flow, Sheet Flow Woods: Dense underbrush n= 0.800 P2= 3.23" Shallow Concentrated Flow, Shallow Concentrated Flow 1 Forest w/Heavy Litter Kv= 2.5 fps Shallow Concentrated Flow, Shallow Concentrated Flow 2 Forest w/Heavy Litter Kv= 2.5 fps Shallow Concentrated Flow, Shallow Concentrated Flow 3 Forest w/Heavy Litter Kv= 2.5 fps
Summary for Subcatchment 3S: E-DA-3 Runoff
=
13.23 cfs @ 12.52 hrs, Volume=
1.855 af, Depth> 2.71"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 100-YR NRCC Rainfall=8.59" Area (ac) 0.077 0.244 0.013 0.071 2.320 4.202 0.198 0.081 0.994 0.021 8.221 7.816 0.405 0.071
CN 98 98 98 98 30 55 77 39 61 80 51
Description Paved parking, HSG A Paved parking, HSG B Paved parking, HSG D Unconnected roofs, HSG B Woods, Good, HSG A Woods, Good, HSG B Woods, Good, HSG D >75% Grass cover, Good, HSG A >75% Grass cover, Good, HSG B >75% Grass cover, Good, HSG D Weighted Average 95.07% Pervious Area 4.93% Impervious Area 17.53% Unconnected
Tc Length Slope (min) (feet) (ft/ft) 14.8 50 0.0500
Velocity (ft/sec) 0.06
12.1
347
0.0363
0.48
7.0
301
0.0830
0.72
33.9
698
Total
Capacity (cfs)
Description Sheet Flow, Sheet Flow Woods: Dense underbrush n= 0.800 P2= 3.23" Shallow Concentrated Flow, Shallow Concentrated Flow 1 Forest w/Heavy Litter Kv= 2.5 fps Shallow Concentrated Flow, Shallow Concentrated Flow 2 Forest w/Heavy Litter Kv= 2.5 fps
2836.00 Pre-Development
Type III 24-hr 100-YR NRCC Rainfall=8.59"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Printed 4/24/2017 Page 16
Summary for Reach 10R: E-DP-1 [40] Hint: Not Described (Outflow=Inflow) Inflow Area = Inflow = Outflow =
8.952 ac, 0.00% Impervious, Inflow Depth > 0.91" for 100-YR NRCC event 3.08 cfs @ 12.64 hrs, Volume= 0.676 af 3.08 cfs @ 12.64 hrs, Volume= 0.676 af, Atten= 0%, Lag= 0.0 min
Routing by Stor-Ind+Trans method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs
Summary for Reach 20R: E-DP-2 [40] Hint: Not Described (Outflow=Inflow) Inflow Area = Inflow = Outflow =
6.399 ac, 3.34% Impervious, Inflow Depth > 2.82" for 100-YR NRCC event 10.21 cfs @ 12.57 hrs, Volume= 1.503 af 10.21 cfs @ 12.57 hrs, Volume= 1.503 af, Atten= 0%, Lag= 0.0 min
Routing by Stor-Ind+Trans method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs
Summary for Reach 30R: E-DP-3 [40] Hint: Not Described (Outflow=Inflow) Inflow Area = Inflow = Outflow =
8.221 ac, 4.93% Impervious, Inflow Depth > 2.71" for 100-YR NRCC event 13.23 cfs @ 12.52 hrs, Volume= 1.855 af 13.23 cfs @ 12.52 hrs, Volume= 1.855 af, Atten= 0%, Lag= 0.0 min
Routing by Stor-Ind+Trans method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs
Appendix C Post-Development Hydrologic Analysis
Extreme Precipitation Tables: 42.201°N, 71.531°W
Page 1 of 1
Extreme Precipitation Tables Northeast Regional Climate Center Data represents point estimates calculated from partial duration series. All precipitation amounts are displayed in inches. Smoothing State Location Longitude Latitude Elevation Date/Time
Yes Massachusetts 71.531 degrees West 42.201 degrees North 0 feet Thu, 23 Mar 2017 17:26:16 -0400
Extreme Precipitation Estimates 1yr 2yr 5yr 10yr 25yr 50yr 100yr 200yr 500yr
5min 0.29 0.35 0.42 0.47 0.56 0.63 0.72 0.82 0.99
10min 0.44 0.54 0.65 0.74 0.89 1.01 1.17 1.34 1.63
15min 0.54 0.67 0.81 0.93 1.13 1.29 1.51 1.74 2.13
30min 0.71 0.89 1.09 1.27 1.55 1.81 2.13 2.49 3.09
60min 120min 1hr 2hr 3hr 6hr 12hr 24hr 48hr 0.89 1.13 1yr 0.77 1.07 1.31 1.65 2.10 2.68 2.92 1yr 1.11 1.40 2yr 0.96 1.29 1.63 2.04 2.57 3.23 3.52 2yr 1.39 1.77 5yr 1.20 1.61 2.06 2.59 3.24 4.06 4.48 5yr 1.65 2.11 10yr 1.42 1.90 2.46 3.10 3.88 4.84 5.38 10yr 2.06 2.66 25yr 1.78 2.36 3.11 3.93 4.91 6.09 6.87 25yr 2.44 3.19 50yr 2.11 2.79 3.74 4.72 5.88 7.26 8.26 50yr 2.90 3.80 100yr 2.50 3.30 4.47 5.64 7.02 8.66 9.95 100yr 3.44 4.54 200yr 2.97 3.90 5.35 6.76 8.40 10.32 11.98 200yr 4.32 5.75 500yr 3.73 4.87 6.79 8.58 10.65 13.04 15.32 500yr
1day 2.37 2.86 3.59 4.28 5.39 6.42 7.66 9.14 11.54
2day 2.81 3.38 4.31 5.18 6.60 7.95 9.56 11.52 14.73
4day 3.25 3.89 4.93 5.91 7.50 8.99 10.79 12.94 16.47
7day 3.92 4.62 5.83 6.95 8.78 10.47 12.50 14.93 18.89
10day 4.56 5.25 6.52 7.68 9.54 11.26 13.28 15.67 19.51
1yr 2yr 5yr 10yr 25yr 50yr 100yr 200yr 500yr
Lower Confidence Limits 1yr 2yr 5yr 10yr 25yr 50yr 100yr 200yr 500yr
5min 0.23 0.34 0.38 0.42 0.49 0.54 0.59 0.66 0.75
10min 0.35 0.53 0.59 0.65 0.74 0.82 0.90 0.99 1.12
15min 0.43 0.65 0.73 0.81 0.92 1.02 1.13 1.25 1.44
30min 0.58 0.88 1.00 1.13 1.31 1.46 1.63 1.81 2.09
60min 120min 1hr 2hr 3hr 6hr 12hr 24hr 48hr 0.71 0.94 1yr 0.61 0.92 1.07 1.42 1.85 2.35 2.70 1yr 1.08 1.27 2yr 0.93 1.24 1.45 1.91 2.44 3.13 3.40 2yr 1.28 1.52 5yr 1.10 1.48 1.72 2.25 2.86 3.73 4.12 5yr 1.45 1.73 10yr 1.26 1.69 1.95 2.55 3.22 4.27 4.76 10yr 1.73 2.05 25yr 1.49 2.01 2.31 3.02 3.78 5.11 5.72 25yr 1.97 2.33 50yr 1.70 2.28 2.62 3.42 4.26 5.85 6.59 50yr 2.23 2.65 100yr 1.93 2.59 2.97 3.88 4.81 6.71 7.57 100yr 2.53 3.02 200yr 2.18 2.96 3.38 4.42 5.44 7.70 8.68 200yr 2.97 3.60 500yr 2.56 3.52 3.99 5.25 6.42 9.26 10.39 500yr
1day 2.08 2.77 3.31 3.78 4.53 5.18 5.94 6.81 8.19
2day 2.60 3.27 3.97 4.57 5.50 6.34 7.28 8.35 9.99
4day 2.95 3.76 4.54 5.24 6.34 7.33 8.48 9.80 11.90
7day 3.58 4.46 5.36 6.14 7.36 8.43 9.70 11.14 13.38
10day 4.11 5.08 6.02 6.84 8.07 9.18 10.44 11.89 14.14
1yr 2yr 5yr 10yr 25yr 50yr 100yr 200yr 500yr
Upper Confidence Limits 1yr 2yr 5yr 10yr 25yr 50yr 100yr 200yr 500yr
5min 0.32 0.37 0.45 0.54 0.69 0.82 0.99 1.19 1.55
10min 0.49 0.56 0.70 0.83 1.04 1.25 1.50 1.80 2.30
15min 0.60 0.69 0.87 1.03 1.30 1.56 1.88 2.28 2.96
30min 0.81 0.94 1.19 1.44 1.86 2.24 2.71 3.30 4.30
60min 120min 1hr 2hr 3hr 6hr 12hr 24hr 48hr 1.00 1.19 1yr 0.86 1.17 1.37 1.76 2.30 2.93 3.16 1yr 1.16 1.36 2yr 1.00 1.33 1.57 2.04 2.60 3.36 3.66 2yr 1.51 1.78 5yr 1.31 1.74 2.04 2.62 3.31 4.39 4.86 5yr 1.86 2.19 10yr 1.60 2.14 2.50 3.18 3.96 5.39 6.06 10yr 2.44 2.88 25yr 2.11 2.82 3.27 4.08 5.05 7.07 8.12 25yr 3.01 3.54 50yr 2.60 3.46 4.02 4.94 6.06 8.69 10.12 50yr 3.72 4.36 100yr 3.21 4.26 4.93 5.98 7.28 10.67 12.66 100yr 4.60 5.37 200yr 3.97 5.25 6.07 7.24 8.73 13.10 15.85 200yr 6.11 7.08 500yr 5.28 6.92 7.98 9.32 11.12 17.21 21.36 500yr
1day 2.60 2.97 3.89 4.77 6.26 7.69 9.44 11.59 15.23
2day 3.04 3.52 4.67 5.83 7.80 9.73 12.18 15.24 20.54
4day 3.53 4.05 5.37 6.65 8.85 10.98 13.64 16.93 22.55
7day 4.23 4.80 6.35 7.84 10.39 12.84 15.88 19.65 26.05
10day 4.89 5.44 7.04 8.58 11.15 13.62 16.61 20.23 26.30
1yr 2yr 5yr 10yr 25yr 50yr 100yr 200yr 500yr
Powered by ACIS
file:///G:/Projdata/2836/Transfers/In/NRCC/2017-03-23/output.htm
4/24/2017
101AS P-DA-1A
101BS
101AP
110R
P-DA-1B
BASIN-1
P-DP-1
103AS
102AS
P-DA-3A
P-DA-2A
130R
103P
103BS
102BS
102P
120R
P-DP-3
BASIN-3
P-DA-3B
P-DA-2B
BASIN-2
P-DP-2
POST-DEVELOPMENT
Subcat
Reach
Pond
Link
Routing Diagram for 283600HC001A Prepared by Microsoft, Printed 4/26/2017 HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
2836.00 Post-Development
283600HC001A Prepared by Microsoft HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Area Listing (selected nodes) Area (acres)
CN
0.074 2.231 0.021 0.300 7.166 3.970 0.078 0.252 0.013 0.113 0.129 0.053 3.974 4.892 0.316 23.582
39 61 80 96 30 58 98 98 98 98 98 98 30 55 77 46
Description (subcatchment-numbers) >75% Grass cover, Good, HSG A (103AS, 103BS) >75% Grass cover, Good, HSG B (102AS, 103AS, 103BS) >75% Grass cover, Good, HSG D (103AS) Gravel surface, HSG B (101BS, 102BS, 103BS) Meadow, non-grazed, HSG A (101AS, 101BS, 103AS, 103BS) Meadow, non-grazed, HSG B (101BS, 102AS, 102BS, 103BS) Paved parking, HSG A (103AS, 103BS) Paved parking, HSG B (103BS) Paved parking, HSG D (103AS) Unconnected pavement, HSG B (101BS, 102AS) Unconnected roofs, HSG B (102AS, 103BS) Water Surface, HSG B (102AS) Woods, Good, HSG A (101AS, 101BS, 102AS, 103AS, 103BS) Woods, Good, HSG B (101BS, 102AS, 102BS, 103AS, 103BS) Woods, Good, HSG D (101AS, 102AS, 103AS) TOTAL AREA
Printed 4/26/2017 Page 2
2836.00 Post-Development
283600HC001A Prepared by Microsoft HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Soil Listing (selected nodes) Area (acres)
Soil Group
Subcatchment Numbers
11.292 11.940 0.000 0.350 0.000 23.582
HSG A HSG B HSG C HSG D Other
101AS, 101BS, 102AS, 103AS, 103BS 101BS, 102AS, 102BS, 103AS, 103BS 101AS, 102AS, 103AS TOTAL AREA
Printed 4/26/2017 Page 3
2836.00 Post-Development
283600HC001A Printed 4/26/2017 Page 4
Prepared by Microsoft HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Ground Covers (selected nodes) HSG-A (acres)
HSG-B (acres)
HSG-C (acres)
HSG-D (acres)
Other (acres)
Total (acres)
0.074
2.231
0.000
0.021
0.000
2.326
0.000
0.300
0.000
0.000
0.000
0.300
7.166
3.970
0.000
0.000
0.000
11.136
0.078
0.252
0.000
0.013
0.000
0.343
0.000
0.113
0.000
0.000
0.000
0.113
0.000
0.129
0.000
0.000
0.000
0.129
0.000 3.974
0.053 4.892
0.000 0.000
0.000 0.316
0.000 0.000
0.053 9.182
11.292
11.940
0.000
0.350
0.000
23.582
Ground Cover
Subcatchment Numbers
>75% Grass cover, Good 102AS, 103AS, 103BS Gravel surface 101BS, 102BS, 103BS Meadow, non-grazed 101AS, 101BS, 102AS, 102BS, 103AS, 103BS Paved parking 103AS, 103BS Unconnected pavement 101BS, 102AS Unconnected roofs 102AS, 103BS Water Surface 102AS Woods, Good 101AS, 101BS, 102AS, 102BS, 103AS, 103BS TOTAL AREA
2836.00 Post-Development
Type III 24-hr 2-YR NRCC Rainfall=3.22"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Printed 4/26/2017 Page 5
Summary for Subcatchment 101AS: P-DA-1A [45] Hint: Runoff=Zero Runoff
=
0.00 cfs @
0.00 hrs, Volume=
0.000 af, Depth= 0.00"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 2-YR NRCC Rainfall=3.22" Area (ac) 1.479 0.001 0.403 1.883 1.883
CN 30 77 30 30
Tc Length (min) (feet) 6.0
Description Woods, Good, HSG A Woods, Good, HSG D Meadow, non-grazed, HSG A Weighted Average 100.00% Pervious Area Slope (ft/ft)
Velocity (ft/sec)
Capacity (cfs)
Description Direct Entry, Minimum
Summary for Subcatchment 101BS: P-DA-1B [45] Hint: Runoff=Zero Runoff
=
0.00 cfs @
0.00 hrs, Volume=
0.000 af, Depth= 0.00"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 2-YR NRCC Rainfall=3.22" Area (ac) 0.452 2.021 5.336 0.363 0.008 0.051 8.231 8.223 0.008 0.008
CN 30 55 30 58 98 96 38
Description Woods, Good, HSG A Woods, Good, HSG B Meadow, non-grazed, HSG A Meadow, non-grazed, HSG B Unconnected pavement, HSG B Gravel surface, HSG B Weighted Average 99.90% Pervious Area 0.10% Impervious Area 100.00% Unconnected
Tc Length Slope (min) (feet) (ft/ft) 13.0 50 0.0690
Velocity (ft/sec) 0.06
12.8
292
0.0231
0.38
5.4
260
0.1045
0.81
31.2
602
Total
Capacity (cfs)
Description Sheet Flow, Sheet Flow Woods: Dense underbrush n= 0.800 P2= 3.23" Shallow Concentrated Flow, Shallow Concentrated Flow 1 Forest w/Heavy Litter Kv= 2.5 fps Shallow Concentrated Flow, Shallow Concentrated Flow 2 Forest w/Heavy Litter Kv= 2.5 fps
2836.00 Post-Development
Type III 24-hr 2-YR NRCC Rainfall=3.22"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Printed 4/26/2017 Page 6
Summary for Subcatchment 102AS: P-DA-2A Runoff
=
0.19 cfs @ 12.49 hrs, Volume=
0.057 af, Depth> 0.18"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 2-YR NRCC Rainfall=3.22" Area (ac) 0.105 0.053 0.057 1.156 0.773 0.117 1.205 0.432 3.898 3.683 0.215 0.162
CN 98 98 98 30 55 77 61 58 53
Adj
52
Tc Length Slope (min) (feet) (ft/ft) 3.8 50 0.0514
Description Unconnected pavement, HSG B Water Surface, HSG B Unconnected roofs, HSG B Woods, Good, HSG A Woods, Good, HSG B Woods, Good, HSG D >75% Grass cover, Good, HSG B Meadow, non-grazed, HSG B Weighted Average, UI Adjusted 94.48% Pervious Area 5.52% Impervious Area 75.35% Unconnected Velocity (ft/sec) 0.22
4.3
208
0.0133
0.81
1.3
168
0.0954
2.16
2.2
121
0.0165
0.90
11.6
547
Total
Capacity (cfs)
Description Sheet Flow, Sheet Flow Grass: Short n= 0.150 P2= 3.23" Shallow Concentrated Flow, Shallow Concentrated Flow 1 Short Grass Pasture Kv= 7.0 fps Shallow Concentrated Flow, Shallow Concentrated Flow 2 Short Grass Pasture Kv= 7.0 fps Shallow Concentrated Flow, Shallow Concentrated Flow 3 Short Grass Pasture Kv= 7.0 fps
Summary for Subcatchment 102BS: P-DA-2B Runoff
=
0.39 cfs @ 12.20 hrs, Volume=
0.051 af, Depth> 0.45"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 2-YR NRCC Rainfall=3.22" Area (ac) 0.106 1.138 0.106 1.350 1.350
CN 55 58 96 61
Description Woods, Good, HSG B Meadow, non-grazed, HSG B Gravel surface, HSG B Weighted Average 100.00% Pervious Area
2836.00 Post-Development
Type III 24-hr 2-YR NRCC Rainfall=3.22"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Tc Length Slope (min) (feet) (ft/ft) 6.4 50 0.0144 3.4
172
0.1 9.9
Velocity (ft/sec) 0.13
0.0144
0.84
15 0.2000
3.13
237
Capacity (cfs)
Printed 4/26/2017 Page 7
Description Sheet Flow, Sheet Flow Grass: Short n= 0.150 P2= 3.23" Shallow Concentrated Flow, Shallow Concentrated Flow 1 Short Grass Pasture Kv= 7.0 fps Shallow Concentrated Flow, Shallow Concentrated Flow 2 Short Grass Pasture Kv= 7.0 fps
Total
Summary for Subcatchment 103AS: P-DA-3A Runoff
=
0.00 cfs @ 21.38 hrs, Volume=
0.002 af, Depth> 0.01"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 2-YR NRCC Rainfall=3.22" Area (ac) 0.022 0.013 0.670 0.068 0.198 0.020 0.044 0.021 0.236 1.292 1.257 0.035
CN 98 98 30 55 77 39 61 80 30 42
Tc Length (min) (feet) 6.0
Description Paved parking, HSG A Paved parking, HSG D Woods, Good, HSG A Woods, Good, HSG B Woods, Good, HSG D >75% Grass cover, Good, HSG A >75% Grass cover, Good, HSG B >75% Grass cover, Good, HSG D Meadow, non-grazed, HSG A Weighted Average 97.29% Pervious Area 2.71% Impervious Area Slope (ft/ft)
Velocity (ft/sec)
Capacity (cfs)
Description Direct Entry, Minimum
Summary for Subcatchment 103BS: P-DA-3B Runoff
=
0.54 cfs @ 12.51 hrs, Volume=
0.131 af, Depth> 0.23"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 2-YR NRCC Rainfall=3.22"
2836.00 Post-Development
Type III 24-hr 2-YR NRCC Rainfall=3.22"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Area (ac) 0.056 0.252 0.072 0.217 1.924 0.054 0.982 1.191 2.037 0.143 6.928 6.548 0.380 0.072
CN 98 98 98 30 55 39 61 30 58 96 55
Adj
54
Tc Length Slope (min) (feet) (ft/ft) 9.8 50 0.0050
Description Paved parking, HSG A Paved parking, HSG B Unconnected roofs, HSG B Woods, Good, HSG A Woods, Good, HSG B >75% Grass cover, Good, HSG A >75% Grass cover, Good, HSG B Meadow, non-grazed, HSG A Meadow, non-grazed, HSG B Gravel surface, HSG B Weighted Average, UI Adjusted 94.52% Pervious Area 5.48% Impervious Area 18.95% Unconnected Velocity (ft/sec) 0.09
4.3
347
0.0363
1.33
1.8
192
0.0625
1.75
31 0.0955
2.16
0.2 16.1
620
Printed 4/26/2017 Page 8
Capacity (cfs)
Description Sheet Flow, Sheet Flow Grass: Short n= 0.150 P2= 3.23" Shallow Concentrated Flow, Shallow Concentrated Flow 1 Short Grass Pasture Kv= 7.0 fps Shallow Concentrated Flow, Shallow Concentrated Flow 2 Short Grass Pasture Kv= 7.0 fps Shallow Concentrated Flow, Shallow Concentrated Flow 3 Short Grass Pasture Kv= 7.0 fps
Total
Summary for Reach 110R: P-DP-1 [40] Hint: Not Described (Outflow=Inflow) Inflow Area = Inflow = Outflow =
10.114 ac, 0.08% Impervious, Inflow Depth = 0.00" for 2-YR NRCC event 0.00 cfs @ 0.00 hrs, Volume= 0.000 af 0.00 cfs @ 0.00 hrs, Volume= 0.000 af, Atten= 0%, Lag= 0.0 min
Routing by Stor-Ind+Trans method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs
Summary for Reach 120R: P-DP-2 [40] Hint: Not Described (Outflow=Inflow) Inflow Area = Inflow = Outflow =
5.248 ac, 4.10% Impervious, Inflow Depth > 0.13" for 2-YR NRCC event 0.19 cfs @ 12.49 hrs, Volume= 0.057 af 0.19 cfs @ 12.49 hrs, Volume= 0.057 af, Atten= 0%, Lag= 0.0 min
Routing by Stor-Ind+Trans method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs
2836.00 Post-Development
Type III 24-hr 2-YR NRCC Rainfall=3.22"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Printed 4/26/2017 Page 9
Summary for Reach 130R: P-DP-3 [40] Hint: Not Described (Outflow=Inflow) Inflow Area = Inflow = Outflow =
8.220 ac, 5.05% Impervious, Inflow Depth > 0.11" for 2-YR NRCC event 0.14 cfs @ 16.22 hrs, Volume= 0.072 af 0.14 cfs @ 16.22 hrs, Volume= 0.072 af, Atten= 0%, Lag= 0.0 min
Routing by Stor-Ind+Trans method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs
Summary for Pond 101AP: BASIN-1 Inflow Area = Inflow = Outflow = Primary =
8.231 ac, 0.10% Impervious, Inflow Depth = 0.00" for 2-YR NRCC event 0.00 cfs @ 0.00 hrs, Volume= 0.000 af 0.00 cfs @ 0.00 hrs, Volume= 0.000 af, Atten= 0%, Lag= 0.0 min 0.00 cfs @ 0.00 hrs, Volume= 0.000 af
Routing by Stor-Ind method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Peak Elev= 493.00' @ 0.00 hrs Surf.Area= 3,844 sf Storage= 0 cf Plug-Flow detention time= (not calculated: initial storage exceeds outflow) Center-of-Mass det. time= (not calculated: no inflow) Volume #1
Invert 493.00'
Elevation (feet) 493.00 494.00 496.00 Device #1
Avail.Storage 30,824 cf
Surf.Area (sq-ft) 3,844 8,790 15,717
Routing Primary
Invert 495.00'
#2
Primary
494.00'
#3
Primary
493.75'
Storage Description Custom Stage Data (Prismatic)Listed below (Recalc)
Inc.Store (cubic-feet) 0 6,317 24,507
Cum.Store (cubic-feet) 0 6,317 30,824
Outlet Devices 20.0' long x 10.0' breadth Broad-Crested Rectangular Weir Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 Coef. (English) 2.49 2.56 2.70 2.69 2.68 2.69 2.67 2.64 12.0" Round Culvert L= 30.0' CPP, mitered to conform to fill, Ke= 0.700 Inlet / Outlet Invert= 494.00' / 493.00' S= 0.0333 '/' Cc= 0.900 n= 0.013 Corrugated PE, smooth interior, Flow Area= 0.79 sf 12.0" Round Culvert L= 30.0' CPP, mitered to conform to fill, Ke= 0.700 Inlet / Outlet Invert= 493.75' / 493.00' S= 0.0250 '/' Cc= 0.900 n= 0.013 Corrugated PE, smooth interior, Flow Area= 0.79 sf
Primary OutFlow Max=0.00 cfs @ 0.00 hrs HW=493.00' (Free Discharge) 1=Broad-Crested Rectangular Weir ( Controls 0.00 cfs) 2=Culvert ( Controls 0.00 cfs) 3=Culvert ( Controls 0.00 cfs)
2836.00 Post-Development
Type III 24-hr 2-YR NRCC Rainfall=3.22"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Printed 4/26/2017 Page 10
Summary for Pond 102P: BASIN-2 Inflow Area = Inflow = Outflow = Primary =
1.350 ac, 0.00% Impervious, Inflow Depth > 0.45" for 2-YR NRCC event 0.39 cfs @ 12.20 hrs, Volume= 0.051 af 0.00 cfs @ 0.00 hrs, Volume= 0.000 af, Atten= 100%, Lag= 0.0 min 0.00 cfs @ 0.00 hrs, Volume= 0.000 af
Routing by Stor-Ind method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Peak Elev= 526.21' @ 24.00 hrs Surf.Area= 11,073 sf Storage= 2,207 cf Plug-Flow detention time= (not calculated: initial storage exceeds outflow) Center-of-Mass det. time= (not calculated: no outflow) Volume #1
Invert 526.00'
Elevation (feet) 526.00 528.00 Device #1 #2
Avail.Storage 28,174 cf
Surf.Area (sq-ft) 10,288 17,886
Storage Description Basin (Prismatic) Listed below (Recalc)
Inc.Store (cubic-feet) 0 28,174
Routing Primary
Invert 527.00'
Primary
526.25'
Cum.Store (cubic-feet) 0 28,174
Outlet Devices 20.0' long x 10.0' breadth Riprap Overflow Weir Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 Coef. (English) 2.49 2.56 2.70 2.69 2.68 2.69 2.67 2.64 6.0" Round Culvert L= 60.0' CPP, mitered to conform to fill, Ke= 0.700 Inlet / Outlet Invert= 526.25' / 525.00' S= 0.0208 '/' Cc= 0.900 n= 0.013 Corrugated PE, smooth interior, Flow Area= 0.20 sf
Primary OutFlow Max=0.00 cfs @ 0.00 hrs HW=526.00' (Free Discharge) 1=Riprap Overflow Weir ( Controls 0.00 cfs) 2=Culvert ( Controls 0.00 cfs)
Summary for Pond 103P: BASIN-3 Inflow Area = Inflow = Outflow = Primary =
6.928 ac, 0.54 cfs @ 0.13 cfs @ 0.13 cfs @
5.48% Impervious, Inflow Depth > 0.23" for 2-YR NRCC event 12.51 hrs, Volume= 0.131 af 16.20 hrs, Volume= 0.070 af, Atten= 75%, Lag= 221.5 min 16.20 hrs, Volume= 0.070 af
Routing by Stor-Ind method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Peak Elev= 501.52' @ 16.20 hrs Surf.Area= 6,278 sf Storage= 2,867 cf Plug-Flow detention time= 315.9 min calculated for 0.070 af (54% of inflow) Center-of-Mass det. time= 163.4 min ( 1,131.9 - 968.6 )
2836.00 Post-Development
Type III 24-hr 2-YR NRCC Rainfall=3.22"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Volume #1
Invert 501.00'
Elevation (feet) 501.00 502.00 504.00 Device #1
Avail.Storage 28,347 cf
Surf.Area (sq-ft) 4,660 7,748 14,395
Routing Primary
Invert 503.00'
#2
Primary
501.42'
#3
Primary
501.42'
Printed 4/26/2017 Page 11
Storage Description Custom Stage Data (Prismatic)Listed below (Recalc)
Inc.Store (cubic-feet) 0 6,204 22,143
Cum.Store (cubic-feet) 0 6,204 28,347
Outlet Devices 20.0' long x 10.0' breadth Broad-Crested Rectangular Weir Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 Coef. (English) 2.49 2.56 2.70 2.69 2.68 2.69 2.67 2.64 12.0" Round Culvert X 2.00 L= 35.0' CPP, mitered to conform to fill, Ke= 0.700 Inlet / Outlet Invert= 501.42' / 500.00' S= 0.0406 '/' Cc= 0.900 n= 0.013 Corrugated PE, smooth interior, Flow Area= 0.79 sf 15.0" Round Culvert L= 35.0' CPP, mitered to conform to fill, Ke= 0.700 Inlet / Outlet Invert= 501.42' / 500.00' S= 0.0406 '/' Cc= 0.900 n= 0.013 Corrugated PE, smooth interior, Flow Area= 1.23 sf
Primary OutFlow Max=0.13 cfs @ 16.20 hrs HW=501.52' (Free Discharge) 1=Broad-Crested Rectangular Weir ( Controls 0.00 cfs) 2=Culvert (Inlet Controls 0.08 cfs @ 0.97 fps) 3=Culvert (Inlet Controls 0.05 cfs @ 0.97 fps)
2836.00 Post-Development
Type III 24-hr 10-YR NRCC Rainfall=4.81"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Printed 4/26/2017 Page 12
Summary for Subcatchment 101AS: P-DA-1A [73] Warning: Peak may fall outside time span Runoff
=
0.00 cfs @ 24.00 hrs, Volume=
0.000 af, Depth> 0.00"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 10-YR NRCC Rainfall=4.81" Area (ac) 1.479 0.001 0.403 1.883 1.883
CN 30 77 30 30
Tc Length (min) (feet) 6.0
Description Woods, Good, HSG A Woods, Good, HSG D Meadow, non-grazed, HSG A Weighted Average 100.00% Pervious Area Slope (ft/ft)
Velocity (ft/sec)
Capacity (cfs)
Description Direct Entry, Minimum
Summary for Subcatchment 101BS: P-DA-1B Runoff
=
0.15 cfs @ 14.94 hrs, Volume=
0.090 af, Depth> 0.13"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 10-YR NRCC Rainfall=4.81" Area (ac) 0.452 2.021 5.336 0.363 0.008 0.051 8.231 8.223 0.008 0.008
CN 30 55 30 58 98 96 38
Description Woods, Good, HSG A Woods, Good, HSG B Meadow, non-grazed, HSG A Meadow, non-grazed, HSG B Unconnected pavement, HSG B Gravel surface, HSG B Weighted Average 99.90% Pervious Area 0.10% Impervious Area 100.00% Unconnected
Tc Length Slope (min) (feet) (ft/ft) 13.0 50 0.0690
Velocity (ft/sec) 0.06
12.8
292
0.0231
0.38
5.4
260
0.1045
0.81
31.2
602
Total
Capacity (cfs)
Description Sheet Flow, Sheet Flow Woods: Dense underbrush n= 0.800 P2= 3.23" Shallow Concentrated Flow, Shallow Concentrated Flow 1 Forest w/Heavy Litter Kv= 2.5 fps Shallow Concentrated Flow, Shallow Concentrated Flow 2 Forest w/Heavy Litter Kv= 2.5 fps
2836.00 Post-Development
Type III 24-hr 10-YR NRCC Rainfall=4.81"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Printed 4/26/2017 Page 13
Summary for Subcatchment 102AS: P-DA-2A Runoff
=
1.81 cfs @ 12.22 hrs, Volume=
0.233 af, Depth> 0.72"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 10-YR NRCC Rainfall=4.81" Area (ac) 0.105 0.053 0.057 1.156 0.773 0.117 1.205 0.432 3.898 3.683 0.215 0.162
CN 98 98 98 30 55 77 61 58 53
Adj
52
Tc Length Slope (min) (feet) (ft/ft) 3.8 50 0.0514
Description Unconnected pavement, HSG B Water Surface, HSG B Unconnected roofs, HSG B Woods, Good, HSG A Woods, Good, HSG B Woods, Good, HSG D >75% Grass cover, Good, HSG B Meadow, non-grazed, HSG B Weighted Average, UI Adjusted 94.48% Pervious Area 5.52% Impervious Area 75.35% Unconnected Velocity (ft/sec) 0.22
4.3
208
0.0133
0.81
1.3
168
0.0954
2.16
2.2
121
0.0165
0.90
11.6
547
Total
Capacity (cfs)
Description Sheet Flow, Sheet Flow Grass: Short n= 0.150 P2= 3.23" Shallow Concentrated Flow, Shallow Concentrated Flow 1 Short Grass Pasture Kv= 7.0 fps Shallow Concentrated Flow, Shallow Concentrated Flow 2 Short Grass Pasture Kv= 7.0 fps Shallow Concentrated Flow, Shallow Concentrated Flow 3 Short Grass Pasture Kv= 7.0 fps
Summary for Subcatchment 102BS: P-DA-2B Runoff
=
1.54 cfs @ 12.16 hrs, Volume=
0.141 af, Depth> 1.25"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 10-YR NRCC Rainfall=4.81" Area (ac) 0.106 1.138 0.106 1.350 1.350
CN 55 58 96 61
Description Woods, Good, HSG B Meadow, non-grazed, HSG B Gravel surface, HSG B Weighted Average 100.00% Pervious Area
2836.00 Post-Development
Type III 24-hr 10-YR NRCC Rainfall=4.81"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Tc Length Slope (min) (feet) (ft/ft) 6.4 50 0.0144 3.4
172
0.1 9.9
Velocity (ft/sec) 0.13
0.0144
0.84
15 0.2000
3.13
237
Capacity (cfs)
Printed 4/26/2017 Page 14
Description Sheet Flow, Sheet Flow Grass: Short n= 0.150 P2= 3.23" Shallow Concentrated Flow, Shallow Concentrated Flow 1 Short Grass Pasture Kv= 7.0 fps Shallow Concentrated Flow, Shallow Concentrated Flow 2 Short Grass Pasture Kv= 7.0 fps
Total
Summary for Subcatchment 103AS: P-DA-3A Runoff
=
0.10 cfs @ 12.41 hrs, Volume=
0.028 af, Depth> 0.26"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 10-YR NRCC Rainfall=4.81" Area (ac) 0.022 0.013 0.670 0.068 0.198 0.020 0.044 0.021 0.236 1.292 1.257 0.035
CN 98 98 30 55 77 39 61 80 30 42
Tc Length (min) (feet) 6.0
Description Paved parking, HSG A Paved parking, HSG D Woods, Good, HSG A Woods, Good, HSG B Woods, Good, HSG D >75% Grass cover, Good, HSG A >75% Grass cover, Good, HSG B >75% Grass cover, Good, HSG D Meadow, non-grazed, HSG A Weighted Average 97.29% Pervious Area 2.71% Impervious Area Slope (ft/ft)
Velocity (ft/sec)
Capacity (cfs)
Description Direct Entry, Minimum
Summary for Subcatchment 103BS: P-DA-3B Runoff
=
3.64 cfs @ 12.29 hrs, Volume=
0.477 af, Depth> 0.83"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 10-YR NRCC Rainfall=4.81"
2836.00 Post-Development
Type III 24-hr 10-YR NRCC Rainfall=4.81"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Area (ac) 0.056 0.252 0.072 0.217 1.924 0.054 0.982 1.191 2.037 0.143 6.928 6.548 0.380 0.072
CN 98 98 98 30 55 39 61 30 58 96 55
Adj
54
Tc Length Slope (min) (feet) (ft/ft) 9.8 50 0.0050
Description Paved parking, HSG A Paved parking, HSG B Unconnected roofs, HSG B Woods, Good, HSG A Woods, Good, HSG B >75% Grass cover, Good, HSG A >75% Grass cover, Good, HSG B Meadow, non-grazed, HSG A Meadow, non-grazed, HSG B Gravel surface, HSG B Weighted Average, UI Adjusted 94.52% Pervious Area 5.48% Impervious Area 18.95% Unconnected Velocity (ft/sec) 0.09
4.3
347
0.0363
1.33
1.8
192
0.0625
1.75
31 0.0955
2.16
0.2 16.1
620
Printed 4/26/2017 Page 15
Capacity (cfs)
Description Sheet Flow, Sheet Flow Grass: Short n= 0.150 P2= 3.23" Shallow Concentrated Flow, Shallow Concentrated Flow 1 Short Grass Pasture Kv= 7.0 fps Shallow Concentrated Flow, Shallow Concentrated Flow 2 Short Grass Pasture Kv= 7.0 fps Shallow Concentrated Flow, Shallow Concentrated Flow 3 Short Grass Pasture Kv= 7.0 fps
Total
Summary for Reach 110R: P-DP-1 [40] Hint: Not Described (Outflow=Inflow) Inflow Area = Inflow = Outflow =
10.114 ac, 0.08% Impervious, Inflow Depth > 0.00" for 10-YR NRCC event 0.00 cfs @ 24.00 hrs, Volume= 0.000 af 0.00 cfs @ 24.00 hrs, Volume= 0.000 af, Atten= 0%, Lag= 0.0 min
Routing by Stor-Ind+Trans method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs
Summary for Reach 120R: P-DP-2 [40] Hint: Not Described (Outflow=Inflow) Inflow Area = Inflow = Outflow =
5.248 ac, 4.10% Impervious, Inflow Depth > 0.63" for 10-YR NRCC event 1.81 cfs @ 12.22 hrs, Volume= 0.277 af 1.81 cfs @ 12.22 hrs, Volume= 0.277 af, Atten= 0%, Lag= 0.0 min
Routing by Stor-Ind+Trans method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs
2836.00 Post-Development
Type III 24-hr 10-YR NRCC Rainfall=4.81"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Printed 4/26/2017 Page 16
Summary for Reach 130R: P-DP-3 [40] Hint: Not Described (Outflow=Inflow) Inflow Area = Inflow = Outflow =
8.220 ac, 5.05% Impervious, Inflow Depth > 0.64" for 10-YR NRCC event 1.85 cfs @ 12.69 hrs, Volume= 0.439 af 1.85 cfs @ 12.69 hrs, Volume= 0.439 af, Atten= 0%, Lag= 0.0 min
Routing by Stor-Ind+Trans method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs
Summary for Pond 101AP: BASIN-1 Inflow Area = Inflow = Outflow = Primary =
8.231 ac, 0.10% Impervious, Inflow Depth > 0.13" for 10-YR NRCC event 0.15 cfs @ 14.94 hrs, Volume= 0.090 af 0.00 cfs @ 0.00 hrs, Volume= 0.000 af, Atten= 100%, Lag= 0.0 min 0.00 cfs @ 0.00 hrs, Volume= 0.000 af
Routing by Stor-Ind method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Peak Elev= 493.70' @ 24.00 hrs Surf.Area= 7,305 sf Storage= 3,901 cf Plug-Flow detention time= (not calculated: initial storage exceeds outflow) Center-of-Mass det. time= (not calculated: no outflow) Volume #1
Invert 493.00'
Elevation (feet) 493.00 494.00 496.00 Device #1
Avail.Storage 30,824 cf
Surf.Area (sq-ft) 3,844 8,790 15,717
Routing Primary
Invert 495.00'
#2
Primary
494.00'
#3
Primary
493.75'
Storage Description Custom Stage Data (Prismatic)Listed below (Recalc)
Inc.Store (cubic-feet) 0 6,317 24,507
Cum.Store (cubic-feet) 0 6,317 30,824
Outlet Devices 20.0' long x 10.0' breadth Broad-Crested Rectangular Weir Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 Coef. (English) 2.49 2.56 2.70 2.69 2.68 2.69 2.67 2.64 12.0" Round Culvert L= 30.0' CPP, mitered to conform to fill, Ke= 0.700 Inlet / Outlet Invert= 494.00' / 493.00' S= 0.0333 '/' Cc= 0.900 n= 0.013 Corrugated PE, smooth interior, Flow Area= 0.79 sf 12.0" Round Culvert L= 30.0' CPP, mitered to conform to fill, Ke= 0.700 Inlet / Outlet Invert= 493.75' / 493.00' S= 0.0250 '/' Cc= 0.900 n= 0.013 Corrugated PE, smooth interior, Flow Area= 0.79 sf
Primary OutFlow Max=0.00 cfs @ 0.00 hrs HW=493.00' (Free Discharge) 1=Broad-Crested Rectangular Weir ( Controls 0.00 cfs) 2=Culvert ( Controls 0.00 cfs) 3=Culvert ( Controls 0.00 cfs)
2836.00 Post-Development
Type III 24-hr 10-YR NRCC Rainfall=4.81"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Printed 4/26/2017 Page 17
Summary for Pond 102P: BASIN-2 Inflow Area = Inflow = Outflow = Primary =
1.350 ac, 1.54 cfs @ 0.06 cfs @ 0.06 cfs @
0.00% Impervious, Inflow Depth > 1.25" for 10-YR NRCC event 12.16 hrs, Volume= 0.141 af 18.05 hrs, Volume= 0.044 af, Atten= 96%, Lag= 353.3 min 18.05 hrs, Volume= 0.044 af
Routing by Stor-Ind method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Peak Elev= 526.40' @ 18.05 hrs Surf.Area= 11,819 sf Storage= 4,455 cf Plug-Flow detention time= 419.6 min calculated for 0.043 af (31% of inflow) Center-of-Mass det. time= 271.6 min ( 1,148.9 - 877.4 ) Volume #1
Invert 526.00'
Elevation (feet) 526.00 528.00 Device #1 #2
Avail.Storage 28,174 cf
Surf.Area (sq-ft) 10,288 17,886
Storage Description Basin (Prismatic) Listed below (Recalc)
Inc.Store (cubic-feet) 0 28,174
Routing Primary
Invert 527.00'
Primary
526.25'
Cum.Store (cubic-feet) 0 28,174
Outlet Devices 20.0' long x 10.0' breadth Riprap Overflow Weir Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 Coef. (English) 2.49 2.56 2.70 2.69 2.68 2.69 2.67 2.64 6.0" Round Culvert L= 60.0' CPP, mitered to conform to fill, Ke= 0.700 Inlet / Outlet Invert= 526.25' / 525.00' S= 0.0208 '/' Cc= 0.900 n= 0.013 Corrugated PE, smooth interior, Flow Area= 0.20 sf
Primary OutFlow Max=0.06 cfs @ 18.05 hrs HW=526.40' (Free Discharge) 1=Riprap Overflow Weir ( Controls 0.00 cfs) 2=Culvert (Inlet Controls 0.06 cfs @ 1.18 fps)
Summary for Pond 103P: BASIN-3 Inflow Area = Inflow = Outflow = Primary =
6.928 ac, 3.64 cfs @ 1.78 cfs @ 1.78 cfs @
5.48% Impervious, Inflow Depth > 0.83" for 10-YR NRCC event 12.29 hrs, Volume= 0.477 af 12.69 hrs, Volume= 0.410 af, Atten= 51%, Lag= 24.1 min 12.69 hrs, Volume= 0.410 af
Routing by Stor-Ind method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Peak Elev= 501.82' @ 12.69 hrs Surf.Area= 7,201 sf Storage= 4,880 cf Plug-Flow detention time= 108.1 min calculated for 0.410 af (86% of inflow) Center-of-Mass det. time= 45.8 min ( 952.9 - 907.2 )
2836.00 Post-Development
Type III 24-hr 10-YR NRCC Rainfall=4.81"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Volume #1
Invert 501.00'
Elevation (feet) 501.00 502.00 504.00 Device #1
Avail.Storage 28,347 cf
Surf.Area (sq-ft) 4,660 7,748 14,395
Routing Primary
Invert 503.00'
#2
Primary
501.42'
#3
Primary
501.42'
Printed 4/26/2017 Page 18
Storage Description Custom Stage Data (Prismatic)Listed below (Recalc)
Inc.Store (cubic-feet) 0 6,204 22,143
Cum.Store (cubic-feet) 0 6,204 28,347
Outlet Devices 20.0' long x 10.0' breadth Broad-Crested Rectangular Weir Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 Coef. (English) 2.49 2.56 2.70 2.69 2.68 2.69 2.67 2.64 12.0" Round Culvert X 2.00 L= 35.0' CPP, mitered to conform to fill, Ke= 0.700 Inlet / Outlet Invert= 501.42' / 500.00' S= 0.0406 '/' Cc= 0.900 n= 0.013 Corrugated PE, smooth interior, Flow Area= 0.79 sf 15.0" Round Culvert L= 35.0' CPP, mitered to conform to fill, Ke= 0.700 Inlet / Outlet Invert= 501.42' / 500.00' S= 0.0406 '/' Cc= 0.900 n= 0.013 Corrugated PE, smooth interior, Flow Area= 1.23 sf
Primary OutFlow Max=1.78 cfs @ 12.69 hrs HW=501.82' (Free Discharge) 1=Broad-Crested Rectangular Weir ( Controls 0.00 cfs) 2=Culvert (Inlet Controls 1.13 cfs @ 1.91 fps) 3=Culvert (Inlet Controls 0.65 cfs @ 1.91 fps)
2836.00 Post-Development
Type III 24-hr 25-YR NRCC Rainfall=6.05"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Printed 4/26/2017 Page 19
Summary for Subcatchment 101AS: P-DA-1A Runoff
=
0.02 cfs @ 15.43 hrs, Volume=
0.012 af, Depth> 0.08"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 25-YR NRCC Rainfall=6.05" Area (ac) 1.479 0.001 0.403 1.883 1.883
CN 30 77 30 30
Tc Length (min) (feet) 6.0
Description Woods, Good, HSG A Woods, Good, HSG D Meadow, non-grazed, HSG A Weighted Average 100.00% Pervious Area Slope (ft/ft)
Velocity (ft/sec)
Capacity (cfs)
Description Direct Entry, Minimum
Summary for Subcatchment 101BS: P-DA-1B Runoff
=
0.86 cfs @ 12.75 hrs, Volume=
0.274 af, Depth> 0.40"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 25-YR NRCC Rainfall=6.05" Area (ac) 0.452 2.021 5.336 0.363 0.008 0.051 8.231 8.223 0.008 0.008
CN 30 55 30 58 98 96 38
Description Woods, Good, HSG A Woods, Good, HSG B Meadow, non-grazed, HSG A Meadow, non-grazed, HSG B Unconnected pavement, HSG B Gravel surface, HSG B Weighted Average 99.90% Pervious Area 0.10% Impervious Area 100.00% Unconnected
Tc Length Slope (min) (feet) (ft/ft) 13.0 50 0.0690
Velocity (ft/sec) 0.06
12.8
292
0.0231
0.38
5.4
260
0.1045
0.81
31.2
602
Total
Capacity (cfs)
Description Sheet Flow, Sheet Flow Woods: Dense underbrush n= 0.800 P2= 3.23" Shallow Concentrated Flow, Shallow Concentrated Flow 1 Forest w/Heavy Litter Kv= 2.5 fps Shallow Concentrated Flow, Shallow Concentrated Flow 2 Forest w/Heavy Litter Kv= 2.5 fps
2836.00 Post-Development
Type III 24-hr 25-YR NRCC Rainfall=6.05"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Printed 4/26/2017 Page 20
Summary for Subcatchment 102AS: P-DA-2A Runoff
=
4.10 cfs @ 12.19 hrs, Volume=
0.426 af, Depth> 1.31"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 25-YR NRCC Rainfall=6.05" Area (ac) 0.105 0.053 0.057 1.156 0.773 0.117 1.205 0.432 3.898 3.683 0.215 0.162
CN 98 98 98 30 55 77 61 58 53
Adj
52
Tc Length Slope (min) (feet) (ft/ft) 3.8 50 0.0514
Description Unconnected pavement, HSG B Water Surface, HSG B Unconnected roofs, HSG B Woods, Good, HSG A Woods, Good, HSG B Woods, Good, HSG D >75% Grass cover, Good, HSG B Meadow, non-grazed, HSG B Weighted Average, UI Adjusted 94.48% Pervious Area 5.52% Impervious Area 75.35% Unconnected Velocity (ft/sec) 0.22
4.3
208
0.0133
0.81
1.3
168
0.0954
2.16
2.2
121
0.0165
0.90
11.6
547
Total
Capacity (cfs)
Description Sheet Flow, Sheet Flow Grass: Short n= 0.150 P2= 3.23" Shallow Concentrated Flow, Shallow Concentrated Flow 1 Short Grass Pasture Kv= 7.0 fps Shallow Concentrated Flow, Shallow Concentrated Flow 2 Short Grass Pasture Kv= 7.0 fps Shallow Concentrated Flow, Shallow Concentrated Flow 3 Short Grass Pasture Kv= 7.0 fps
Summary for Subcatchment 102BS: P-DA-2B Runoff
=
2.66 cfs @ 12.15 hrs, Volume=
0.229 af, Depth> 2.03"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 25-YR NRCC Rainfall=6.05" Area (ac) 0.106 1.138 0.106 1.350 1.350
CN 55 58 96 61
Description Woods, Good, HSG B Meadow, non-grazed, HSG B Gravel surface, HSG B Weighted Average 100.00% Pervious Area
2836.00 Post-Development
Type III 24-hr 25-YR NRCC Rainfall=6.05"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Tc Length Slope (min) (feet) (ft/ft) 6.4 50 0.0144 3.4
172
0.1 9.9
Velocity (ft/sec) 0.13
0.0144
0.84
15 0.2000
3.13
237
Capacity (cfs)
Printed 4/26/2017 Page 21
Description Sheet Flow, Sheet Flow Grass: Short n= 0.150 P2= 3.23" Shallow Concentrated Flow, Shallow Concentrated Flow 1 Short Grass Pasture Kv= 7.0 fps Shallow Concentrated Flow, Shallow Concentrated Flow 2 Short Grass Pasture Kv= 7.0 fps
Total
Summary for Subcatchment 103AS: P-DA-3A Runoff
=
0.43 cfs @ 12.17 hrs, Volume=
0.068 af, Depth> 0.63"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 25-YR NRCC Rainfall=6.05" Area (ac) 0.022 0.013 0.670 0.068 0.198 0.020 0.044 0.021 0.236 1.292 1.257 0.035
CN 98 98 30 55 77 39 61 80 30 42
Tc Length (min) (feet) 6.0
Description Paved parking, HSG A Paved parking, HSG D Woods, Good, HSG A Woods, Good, HSG B Woods, Good, HSG D >75% Grass cover, Good, HSG A >75% Grass cover, Good, HSG B >75% Grass cover, Good, HSG D Meadow, non-grazed, HSG A Weighted Average 97.29% Pervious Area 2.71% Impervious Area Slope (ft/ft)
Velocity (ft/sec)
Capacity (cfs)
Description Direct Entry, Minimum
Summary for Subcatchment 103BS: P-DA-3B Runoff
=
7.58 cfs @ 12.26 hrs, Volume=
0.844 af, Depth> 1.46"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 25-YR NRCC Rainfall=6.05"
2836.00 Post-Development
Type III 24-hr 25-YR NRCC Rainfall=6.05"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Area (ac) 0.056 0.252 0.072 0.217 1.924 0.054 0.982 1.191 2.037 0.143 6.928 6.548 0.380 0.072
CN 98 98 98 30 55 39 61 30 58 96 55
Adj
54
Tc Length Slope (min) (feet) (ft/ft) 9.8 50 0.0050
Description Paved parking, HSG A Paved parking, HSG B Unconnected roofs, HSG B Woods, Good, HSG A Woods, Good, HSG B >75% Grass cover, Good, HSG A >75% Grass cover, Good, HSG B Meadow, non-grazed, HSG A Meadow, non-grazed, HSG B Gravel surface, HSG B Weighted Average, UI Adjusted 94.52% Pervious Area 5.48% Impervious Area 18.95% Unconnected Velocity (ft/sec) 0.09
4.3
347
0.0363
1.33
1.8
192
0.0625
1.75
31 0.0955
2.16
0.2 16.1
620
Printed 4/26/2017 Page 22
Capacity (cfs)
Description Sheet Flow, Sheet Flow Grass: Short n= 0.150 P2= 3.23" Shallow Concentrated Flow, Shallow Concentrated Flow 1 Short Grass Pasture Kv= 7.0 fps Shallow Concentrated Flow, Shallow Concentrated Flow 2 Short Grass Pasture Kv= 7.0 fps Shallow Concentrated Flow, Shallow Concentrated Flow 3 Short Grass Pasture Kv= 7.0 fps
Total
Summary for Reach 110R: P-DP-1 [40] Hint: Not Described (Outflow=Inflow) Inflow Area = Inflow = Outflow =
10.114 ac, 0.08% Impervious, Inflow Depth > 0.18" for 25-YR NRCC event 0.26 cfs @ 17.39 hrs, Volume= 0.153 af 0.26 cfs @ 17.39 hrs, Volume= 0.153 af, Atten= 0%, Lag= 0.0 min
Routing by Stor-Ind+Trans method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs
Summary for Reach 120R: P-DP-2 [40] Hint: Not Described (Outflow=Inflow) Inflow Area = Inflow = Outflow =
5.248 ac, 4.10% Impervious, Inflow Depth > 1.25" for 25-YR NRCC event 4.10 cfs @ 12.19 hrs, Volume= 0.547 af 4.10 cfs @ 12.19 hrs, Volume= 0.547 af, Atten= 0%, Lag= 0.0 min
Routing by Stor-Ind+Trans method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs
2836.00 Post-Development
Type III 24-hr 25-YR NRCC Rainfall=6.05"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Printed 4/26/2017 Page 23
Summary for Reach 130R: P-DP-3 [40] Hint: Not Described (Outflow=Inflow) Inflow Area = Inflow = Outflow =
8.220 ac, 5.05% Impervious, Inflow Depth > 1.23" for 25-YR NRCC event 5.19 cfs @ 12.51 hrs, Volume= 0.842 af 5.19 cfs @ 12.51 hrs, Volume= 0.842 af, Atten= 0%, Lag= 0.0 min
Routing by Stor-Ind+Trans method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs
Summary for Pond 101AP: BASIN-1 Inflow Area = Inflow = Outflow = Primary =
8.231 ac, 0.86 cfs @ 0.24 cfs @ 0.24 cfs @
0.10% Impervious, Inflow Depth > 0.40" for 25-YR NRCC event 12.75 hrs, Volume= 0.274 af 17.44 hrs, Volume= 0.140 af, Atten= 72%, Lag= 281.9 min 17.44 hrs, Volume= 0.140 af
Routing by Stor-Ind method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Peak Elev= 494.01' @ 17.44 hrs Surf.Area= 8,808 sf Storage= 6,364 cf Plug-Flow detention time= 332.1 min calculated for 0.140 af (51% of inflow) Center-of-Mass det. time= 176.5 min ( 1,159.5 - 983.0 ) Volume #1
Invert 493.00'
Elevation (feet) 493.00 494.00 496.00 Device #1
Avail.Storage 30,824 cf
Surf.Area (sq-ft) 3,844 8,790 15,717
Routing Primary
Invert 495.00'
#2
Primary
494.00'
#3
Primary
493.75'
Storage Description Custom Stage Data (Prismatic)Listed below (Recalc)
Inc.Store (cubic-feet) 0 6,317 24,507
Cum.Store (cubic-feet) 0 6,317 30,824
Outlet Devices 20.0' long x 10.0' breadth Broad-Crested Rectangular Weir Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 Coef. (English) 2.49 2.56 2.70 2.69 2.68 2.69 2.67 2.64 12.0" Round Culvert L= 30.0' CPP, mitered to conform to fill, Ke= 0.700 Inlet / Outlet Invert= 494.00' / 493.00' S= 0.0333 '/' Cc= 0.900 n= 0.013 Corrugated PE, smooth interior, Flow Area= 0.79 sf 12.0" Round Culvert L= 30.0' CPP, mitered to conform to fill, Ke= 0.700 Inlet / Outlet Invert= 493.75' / 493.00' S= 0.0250 '/' Cc= 0.900 n= 0.013 Corrugated PE, smooth interior, Flow Area= 0.79 sf
Primary OutFlow Max=0.24 cfs @ 17.44 hrs HW=494.01' (Free Discharge) 1=Broad-Crested Rectangular Weir ( Controls 0.00 cfs) 2=Culvert (Inlet Controls 0.00 cfs @ 0.22 fps) 3=Culvert (Inlet Controls 0.24 cfs @ 1.52 fps)
2836.00 Post-Development
Type III 24-hr 25-YR NRCC Rainfall=6.05"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Printed 4/26/2017 Page 24
Summary for Pond 102P: BASIN-2 Inflow Area = Inflow = Outflow = Primary =
1.350 ac, 2.66 cfs @ 0.17 cfs @ 0.17 cfs @
0.00% Impervious, Inflow Depth > 2.03" for 25-YR NRCC event 12.15 hrs, Volume= 0.229 af 15.45 hrs, Volume= 0.121 af, Atten= 93%, Lag= 198.0 min 15.45 hrs, Volume= 0.121 af
Routing by Stor-Ind method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Peak Elev= 526.52' @ 15.45 hrs Surf.Area= 12,279 sf Storage= 5,914 cf Plug-Flow detention time= 326.6 min calculated for 0.120 af (53% of inflow) Center-of-Mass det. time= 201.0 min ( 1,063.0 - 862.0 ) Volume #1
Invert 526.00'
Elevation (feet) 526.00 528.00 Device #1 #2
Avail.Storage 28,174 cf
Surf.Area (sq-ft) 10,288 17,886
Storage Description Basin (Prismatic) Listed below (Recalc)
Inc.Store (cubic-feet) 0 28,174
Routing Primary
Invert 527.00'
Primary
526.25'
Cum.Store (cubic-feet) 0 28,174
Outlet Devices 20.0' long x 10.0' breadth Riprap Overflow Weir Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 Coef. (English) 2.49 2.56 2.70 2.69 2.68 2.69 2.67 2.64 6.0" Round Culvert L= 60.0' CPP, mitered to conform to fill, Ke= 0.700 Inlet / Outlet Invert= 526.25' / 525.00' S= 0.0208 '/' Cc= 0.900 n= 0.013 Corrugated PE, smooth interior, Flow Area= 0.20 sf
Primary OutFlow Max=0.17 cfs @ 15.45 hrs HW=526.52' (Free Discharge) 1=Riprap Overflow Weir ( Controls 0.00 cfs) 2=Culvert (Inlet Controls 0.17 cfs @ 1.57 fps)
Summary for Pond 103P: BASIN-3 Inflow Area = Inflow = Outflow = Primary =
6.928 ac, 7.58 cfs @ 4.93 cfs @ 4.93 cfs @
5.48% Impervious, Inflow Depth > 1.46" for 25-YR NRCC event 12.26 hrs, Volume= 0.844 af 12.53 hrs, Volume= 0.774 af, Atten= 35%, Lag= 16.1 min 12.53 hrs, Volume= 0.774 af
Routing by Stor-Ind method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Peak Elev= 502.14' @ 12.53 hrs Surf.Area= 8,206 sf Storage= 7,303 cf Plug-Flow detention time= 69.8 min calculated for 0.772 af (91% of inflow) Center-of-Mass det. time= 29.5 min ( 915.9 - 886.4 )
2836.00 Post-Development
Type III 24-hr 25-YR NRCC Rainfall=6.05"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Volume #1
Invert 501.00'
Elevation (feet) 501.00 502.00 504.00 Device #1
Avail.Storage 28,347 cf
Surf.Area (sq-ft) 4,660 7,748 14,395
Routing Primary
Invert 503.00'
#2
Primary
501.42'
#3
Primary
501.42'
Printed 4/26/2017 Page 25
Storage Description Custom Stage Data (Prismatic)Listed below (Recalc)
Inc.Store (cubic-feet) 0 6,204 22,143
Cum.Store (cubic-feet) 0 6,204 28,347
Outlet Devices 20.0' long x 10.0' breadth Broad-Crested Rectangular Weir Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 Coef. (English) 2.49 2.56 2.70 2.69 2.68 2.69 2.67 2.64 12.0" Round Culvert X 2.00 L= 35.0' CPP, mitered to conform to fill, Ke= 0.700 Inlet / Outlet Invert= 501.42' / 500.00' S= 0.0406 '/' Cc= 0.900 n= 0.013 Corrugated PE, smooth interior, Flow Area= 0.79 sf 15.0" Round Culvert L= 35.0' CPP, mitered to conform to fill, Ke= 0.700 Inlet / Outlet Invert= 501.42' / 500.00' S= 0.0406 '/' Cc= 0.900 n= 0.013 Corrugated PE, smooth interior, Flow Area= 1.23 sf
Primary OutFlow Max=4.91 cfs @ 12.53 hrs HW=502.14' (Free Discharge) 1=Broad-Crested Rectangular Weir ( Controls 0.00 cfs) 2=Culvert (Inlet Controls 3.06 cfs @ 2.54 fps) 3=Culvert (Inlet Controls 1.85 cfs @ 2.54 fps)
2836.00 Post-Development
Type III 24-hr 100-YR NRCC Rainfall=8.59"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Printed 4/26/2017 Page 26
Summary for Subcatchment 101AS: P-DA-1A Runoff
=
0.38 cfs @ 12.37 hrs, Volume=
0.088 af, Depth> 0.56"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 100-YR NRCC Rainfall=8.59" Area (ac) 1.479 0.001 0.403 1.883 1.883
CN 30 77 30 30
Tc Length (min) (feet) 6.0
Description Woods, Good, HSG A Woods, Good, HSG D Meadow, non-grazed, HSG A Weighted Average 100.00% Pervious Area Slope (ft/ft)
Velocity (ft/sec)
Capacity (cfs)
Description Direct Entry, Minimum
Summary for Subcatchment 101BS: P-DA-1B Runoff
=
5.05 cfs @ 12.57 hrs, Volume=
0.889 af, Depth> 1.30"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 100-YR NRCC Rainfall=8.59" Area (ac) 0.452 2.021 5.336 0.363 0.008 0.051 8.231 8.223 0.008 0.008
CN 30 55 30 58 98 96 38
Description Woods, Good, HSG A Woods, Good, HSG B Meadow, non-grazed, HSG A Meadow, non-grazed, HSG B Unconnected pavement, HSG B Gravel surface, HSG B Weighted Average 99.90% Pervious Area 0.10% Impervious Area 100.00% Unconnected
Tc Length Slope (min) (feet) (ft/ft) 13.0 50 0.0690
Velocity (ft/sec) 0.06
12.8
292
0.0231
0.38
5.4
260
0.1045
0.81
31.2
602
Total
Capacity (cfs)
Description Sheet Flow, Sheet Flow Woods: Dense underbrush n= 0.800 P2= 3.23" Shallow Concentrated Flow, Shallow Concentrated Flow 1 Forest w/Heavy Litter Kv= 2.5 fps Shallow Concentrated Flow, Shallow Concentrated Flow 2 Forest w/Heavy Litter Kv= 2.5 fps
2836.00 Post-Development
Type III 24-hr 100-YR NRCC Rainfall=8.59"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Printed 4/26/2017 Page 27
Summary for Subcatchment 102AS: P-DA-2A Runoff
=
10.17 cfs @ 12.17 hrs, Volume=
0.922 af, Depth> 2.84"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 100-YR NRCC Rainfall=8.59" Area (ac) 0.105 0.053 0.057 1.156 0.773 0.117 1.205 0.432 3.898 3.683 0.215 0.162
CN 98 98 98 30 55 77 61 58 53
Adj
52
Tc Length Slope (min) (feet) (ft/ft) 3.8 50 0.0514
Description Unconnected pavement, HSG B Water Surface, HSG B Unconnected roofs, HSG B Woods, Good, HSG A Woods, Good, HSG B Woods, Good, HSG D >75% Grass cover, Good, HSG B Meadow, non-grazed, HSG B Weighted Average, UI Adjusted 94.48% Pervious Area 5.52% Impervious Area 75.35% Unconnected Velocity (ft/sec) 0.22
4.3
208
0.0133
0.81
1.3
168
0.0954
2.16
2.2
121
0.0165
0.90
11.6
547
Total
Capacity (cfs)
Description Sheet Flow, Sheet Flow Grass: Short n= 0.150 P2= 3.23" Shallow Concentrated Flow, Shallow Concentrated Flow 1 Short Grass Pasture Kv= 7.0 fps Shallow Concentrated Flow, Shallow Concentrated Flow 2 Short Grass Pasture Kv= 7.0 fps Shallow Concentrated Flow, Shallow Concentrated Flow 3 Short Grass Pasture Kv= 7.0 fps
Summary for Subcatchment 102BS: P-DA-2B Runoff
=
5.30 cfs @ 12.15 hrs, Volume=
0.438 af, Depth> 3.89"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 100-YR NRCC Rainfall=8.59" Area (ac) 0.106 1.138 0.106 1.350 1.350
CN 55 58 96 61
Description Woods, Good, HSG B Meadow, non-grazed, HSG B Gravel surface, HSG B Weighted Average 100.00% Pervious Area
2836.00 Post-Development
Type III 24-hr 100-YR NRCC Rainfall=8.59"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Tc Length Slope (min) (feet) (ft/ft) 6.4 50 0.0144 3.4
172
0.1 9.9
Velocity (ft/sec) 0.13
0.0144
0.84
15 0.2000
3.13
237
Capacity (cfs)
Printed 4/26/2017 Page 28
Description Sheet Flow, Sheet Flow Grass: Short n= 0.150 P2= 3.23" Shallow Concentrated Flow, Shallow Concentrated Flow 1 Short Grass Pasture Kv= 7.0 fps Shallow Concentrated Flow, Shallow Concentrated Flow 2 Short Grass Pasture Kv= 7.0 fps
Total
Summary for Subcatchment 103AS: P-DA-3A Runoff
=
2.10 cfs @ 12.11 hrs, Volume=
0.186 af, Depth> 1.73"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 100-YR NRCC Rainfall=8.59" Area (ac) 0.022 0.013 0.670 0.068 0.198 0.020 0.044 0.021 0.236 1.292 1.257 0.035
CN 98 98 30 55 77 39 61 80 30 42
Tc Length (min) (feet) 6.0
Description Paved parking, HSG A Paved parking, HSG D Woods, Good, HSG A Woods, Good, HSG B Woods, Good, HSG D >75% Grass cover, Good, HSG A >75% Grass cover, Good, HSG B >75% Grass cover, Good, HSG D Meadow, non-grazed, HSG A Weighted Average 97.29% Pervious Area 2.71% Impervious Area Slope (ft/ft)
Velocity (ft/sec)
Capacity (cfs)
Description Direct Entry, Minimum
Summary for Subcatchment 103BS: P-DA-3B Runoff
=
17.53 cfs @ 12.24 hrs, Volume=
1.771 af, Depth> 3.07"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Type III 24-hr 100-YR NRCC Rainfall=8.59"
2836.00 Post-Development
Type III 24-hr 100-YR NRCC Rainfall=8.59"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Area (ac) 0.056 0.252 0.072 0.217 1.924 0.054 0.982 1.191 2.037 0.143 6.928 6.548 0.380 0.072
CN 98 98 98 30 55 39 61 30 58 96 55
Adj
54
Tc Length Slope (min) (feet) (ft/ft) 9.8 50 0.0050
Description Paved parking, HSG A Paved parking, HSG B Unconnected roofs, HSG B Woods, Good, HSG A Woods, Good, HSG B >75% Grass cover, Good, HSG A >75% Grass cover, Good, HSG B Meadow, non-grazed, HSG A Meadow, non-grazed, HSG B Gravel surface, HSG B Weighted Average, UI Adjusted 94.52% Pervious Area 5.48% Impervious Area 18.95% Unconnected Velocity (ft/sec) 0.09
4.3
347
0.0363
1.33
1.8
192
0.0625
1.75
31 0.0955
2.16
0.2 16.1
620
Printed 4/26/2017 Page 29
Capacity (cfs)
Description Sheet Flow, Sheet Flow Grass: Short n= 0.150 P2= 3.23" Shallow Concentrated Flow, Shallow Concentrated Flow 1 Short Grass Pasture Kv= 7.0 fps Shallow Concentrated Flow, Shallow Concentrated Flow 2 Short Grass Pasture Kv= 7.0 fps Shallow Concentrated Flow, Shallow Concentrated Flow 3 Short Grass Pasture Kv= 7.0 fps
Total
Summary for Reach 110R: P-DP-1 [40] Hint: Not Described (Outflow=Inflow) Inflow Area = Inflow = Outflow =
10.114 ac, 0.08% Impervious, Inflow Depth > 0.98" for 100-YR NRCC event 2.24 cfs @ 13.27 hrs, Volume= 0.825 af 2.24 cfs @ 13.27 hrs, Volume= 0.825 af, Atten= 0%, Lag= 0.0 min
Routing by Stor-Ind+Trans method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs
Summary for Reach 120R: P-DP-2 [40] Hint: Not Described (Outflow=Inflow) Inflow Area = Inflow = Outflow =
5.248 ac, 4.10% Impervious, Inflow Depth > 2.82" for 100-YR NRCC event 10.19 cfs @ 12.18 hrs, Volume= 1.235 af 10.19 cfs @ 12.18 hrs, Volume= 1.235 af, Atten= 0%, Lag= 0.0 min
Routing by Stor-Ind+Trans method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs
2836.00 Post-Development
Type III 24-hr 100-YR NRCC Rainfall=8.59"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Printed 4/26/2017 Page 30
Summary for Reach 130R: P-DP-3 [40] Hint: Not Described (Outflow=Inflow) Inflow Area = Inflow = Outflow =
8.220 ac, 5.05% Impervious, Inflow Depth > 2.74" for 100-YR NRCC event 12.24 cfs @ 12.43 hrs, Volume= 1.880 af 12.24 cfs @ 12.43 hrs, Volume= 1.880 af, Atten= 0%, Lag= 0.0 min
Routing by Stor-Ind+Trans method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs
Summary for Pond 101AP: BASIN-1 Inflow Area = Inflow = Outflow = Primary =
8.231 ac, 5.05 cfs @ 2.07 cfs @ 2.07 cfs @
0.10% Impervious, Inflow Depth > 1.30" for 100-YR NRCC event 12.57 hrs, Volume= 0.889 af 13.27 hrs, Volume= 0.736 af, Atten= 59%, Lag= 42.5 min 13.27 hrs, Volume= 0.736 af
Routing by Stor-Ind method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Peak Elev= 494.43' @ 13.27 hrs Surf.Area= 10,296 sf Storage= 10,466 cf Plug-Flow detention time= 134.8 min calculated for 0.735 af (83% of inflow) Center-of-Mass det. time= 63.0 min ( 988.8 - 925.8 ) Volume #1
Invert 493.00'
Elevation (feet) 493.00 494.00 496.00 Device #1
Avail.Storage 30,824 cf
Surf.Area (sq-ft) 3,844 8,790 15,717
Routing Primary
Invert 495.00'
#2
Primary
494.00'
#3
Primary
493.75'
Storage Description Custom Stage Data (Prismatic)Listed below (Recalc)
Inc.Store (cubic-feet) 0 6,317 24,507
Cum.Store (cubic-feet) 0 6,317 30,824
Outlet Devices 20.0' long x 10.0' breadth Broad-Crested Rectangular Weir Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 Coef. (English) 2.49 2.56 2.70 2.69 2.68 2.69 2.67 2.64 12.0" Round Culvert L= 30.0' CPP, mitered to conform to fill, Ke= 0.700 Inlet / Outlet Invert= 494.00' / 493.00' S= 0.0333 '/' Cc= 0.900 n= 0.013 Corrugated PE, smooth interior, Flow Area= 0.79 sf 12.0" Round Culvert L= 30.0' CPP, mitered to conform to fill, Ke= 0.700 Inlet / Outlet Invert= 493.75' / 493.00' S= 0.0250 '/' Cc= 0.900 n= 0.013 Corrugated PE, smooth interior, Flow Area= 0.79 sf
Primary OutFlow Max=2.07 cfs @ 13.27 hrs HW=494.43' (Free Discharge) 1=Broad-Crested Rectangular Weir ( Controls 0.00 cfs) 2=Culvert (Inlet Controls 0.65 cfs @ 1.98 fps) 3=Culvert (Inlet Controls 1.42 cfs @ 2.49 fps)
2836.00 Post-Development
Type III 24-hr 100-YR NRCC Rainfall=8.59"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Printed 4/26/2017 Page 31
Summary for Pond 102P: BASIN-2 Inflow Area = Inflow = Outflow = Primary =
1.350 ac, 5.30 cfs @ 0.49 cfs @ 0.49 cfs @
0.00% Impervious, Inflow Depth > 3.89" for 100-YR NRCC event 12.15 hrs, Volume= 0.438 af 13.76 hrs, Volume= 0.313 af, Atten= 91%, Lag= 96.7 min 13.76 hrs, Volume= 0.313 af
Routing by Stor-Ind method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Peak Elev= 526.84' @ 13.76 hrs Surf.Area= 13,478 sf Storage= 9,976 cf Plug-Flow detention time= 264.8 min calculated for 0.313 af (71% of inflow) Center-of-Mass det. time= 168.8 min ( 1,011.6 - 842.8 ) Volume #1
Invert 526.00'
Elevation (feet) 526.00 528.00 Device #1 #2
Avail.Storage 28,174 cf
Surf.Area (sq-ft) 10,288 17,886
Storage Description Basin (Prismatic) Listed below (Recalc)
Inc.Store (cubic-feet) 0 28,174
Routing Primary
Invert 527.00'
Primary
526.25'
Cum.Store (cubic-feet) 0 28,174
Outlet Devices 20.0' long x 10.0' breadth Riprap Overflow Weir Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 Coef. (English) 2.49 2.56 2.70 2.69 2.68 2.69 2.67 2.64 6.0" Round Culvert L= 60.0' CPP, mitered to conform to fill, Ke= 0.700 Inlet / Outlet Invert= 526.25' / 525.00' S= 0.0208 '/' Cc= 0.900 n= 0.013 Corrugated PE, smooth interior, Flow Area= 0.20 sf
Primary OutFlow Max=0.49 cfs @ 13.76 hrs HW=526.84' (Free Discharge) 1=Riprap Overflow Weir ( Controls 0.00 cfs) 2=Culvert (Inlet Controls 0.49 cfs @ 2.48 fps)
Summary for Pond 103P: BASIN-3 Inflow Area = Inflow = Outflow = Primary =
6.928 ac, 17.53 cfs @ 11.36 cfs @ 11.36 cfs @
5.48% Impervious, Inflow Depth > 3.07" for 100-YR NRCC event 12.24 hrs, Volume= 1.771 af 12.48 hrs, Volume= 1.694 af, Atten= 35%, Lag= 14.4 min 12.48 hrs, Volume= 1.694 af
Routing by Stor-Ind method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrs Peak Elev= 502.89' @ 12.48 hrs Surf.Area= 10,704 sf Storage= 14,409 cf Plug-Flow detention time= 43.8 min calculated for 1.694 af (96% of inflow) Center-of-Mass det. time= 20.8 min ( 883.8 - 863.0 )
2836.00 Post-Development
Type III 24-hr 100-YR NRCC Rainfall=8.59"
283600HC001A Prepared by Microsoft
HydroCAD® 10.00-15 s/n 04493 © 2015 HydroCAD Software Solutions LLC
Volume #1
Invert 501.00'
Elevation (feet) 501.00 502.00 504.00 Device #1
Avail.Storage 28,347 cf
Surf.Area (sq-ft) 4,660 7,748 14,395
Routing Primary
Invert 503.00'
#2
Primary
501.42'
#3
Primary
501.42'
Printed 4/26/2017 Page 32
Storage Description Custom Stage Data (Prismatic)Listed below (Recalc)
Inc.Store (cubic-feet) 0 6,204 22,143
Cum.Store (cubic-feet) 0 6,204 28,347
Outlet Devices 20.0' long x 10.0' breadth Broad-Crested Rectangular Weir Head (feet) 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 Coef. (English) 2.49 2.56 2.70 2.69 2.68 2.69 2.67 2.64 12.0" Round Culvert X 2.00 L= 35.0' CPP, mitered to conform to fill, Ke= 0.700 Inlet / Outlet Invert= 501.42' / 500.00' S= 0.0406 '/' Cc= 0.900 n= 0.013 Corrugated PE, smooth interior, Flow Area= 0.79 sf 15.0" Round Culvert L= 35.0' CPP, mitered to conform to fill, Ke= 0.700 Inlet / Outlet Invert= 501.42' / 500.00' S= 0.0406 '/' Cc= 0.900 n= 0.013 Corrugated PE, smooth interior, Flow Area= 1.23 sf
Primary OutFlow Max=11.35 cfs @ 12.48 hrs HW=502.89' (Free Discharge) 1=Broad-Crested Rectangular Weir ( Controls 0.00 cfs) 2=Culvert (Inlet Controls 6.56 cfs @ 4.18 fps) 3=Culvert (Inlet Controls 4.78 cfs @ 3.90 fps)
Appendix D Drawdown & Riprap-Sizing Calculation
BEALS+THOMAS Standard 3: Drawdown
Rv (K) (Bottom Area)
Drawdown Time =
where:
Rv = Storage Volume Below Outlet [Ac-ft] K= Infiltration Rate [in/hr] Bottom Area= Bottom Area of Recharge System [Ac]
Basin 1 Rv =
0.107 Ac-ft
K=
0.270 in/hr
Bottom Area =
0.088 Acres
Drawdown Time =
53.856 Hours
(Mapped as HSG "A" & "B"; Rawls Rate for HSG "C" Soils) < 72 Hours, Design is in compliance with the standard.
Basin 2 Rv =
0.075 Ac-ft
K=
0.270 in/hr
Bottom Area =
0.236 Acres
Drawdown Time =
14.070 Hours
(Mapped as HSG "A" & "B"; Rawls Rate for HSG "C" Soils) < 72 Hours, Design is in compliance with the standard.
Basin 3 Rv =
0.062 Ac-ft
K=
0.270 in/hr
Bottom Area =
0.107 Acres
Drawdown Time =
25.904 Hours
(Mapped as HSG "A" & "B"; Rawls Rate for HSG "C" Soils) < 72 Hours, Design is in compliance with the standard.
Note: 1. The infiltration BMPs have been designed to fully drain within 72 hours, therefore the proposed stormwater management design is in compliance with Standard 3 . 2. Infiltration Rate based on Volume 3, Chapter 1, Table 2.3.3 Rawls Rates from the 2008 MA DEP Stormwater Management Handbook. JOB NO. JOB:
283600SWM0001.xlsx
2836.00 CEC Solar #1206, LLC
COMPUTED BY: DATE:
TJM 08/09/17
CHECKED BY: DATE:
BEALS+THOMAS Riprap Apron Sizing
Median Stone Sizing: Where: D0 = Maximum Inside Pipe Diameter (ft) D50 = Median Riprap Diameter (ft) Q = Peak Discharge Rate from Hydraulic Design (cfs) TW = Tailwater Depth (ft); (Use 0.4D0 if TW is unknown, max 1.0Do) 2
g = Gravitational Acceleration Constant = 32.2 ft/s
Apron Sizing: D50 [In]
Apron Length (L) [ft}
Apron Depth [In]
Apron Width At Beginning
Apron Width At End
5 6 10 14 20 22
4D0 4D0 5D0 6D0 7D0 8D0
3.5D50 3.3D50 2.4D50 2.2D50 2.0D50 2.0D50
3D0 3D0 3D0 3D0 3D0 3D0
3D0 + ⅔L 3D0 + ⅔L 3D0 + ⅔L 3D0 + ⅔L 3D0 + ⅔L 3D0 + ⅔L
FLARED END SECTIONS
PIPE DIAMETER (D0) (FEET)
25-YEAR STORM FLOW (Q) (CFS)
12"@Basin #1 (2) 6"@Basin #2 (1) 12"@Basin #3 (2) 15" @Basin #3 (1)
1.00 0.50 1.00 1.25
0.24 0.17 3.06 1.85
MEDIAN STONE TAILWATER DIAMETER (TW) [ft] (D50) (INCHES) 0.4 0.2 0.4 0.5
5 5 5 5
APRON LENGTH (L) (FEET)
APRON DEPTH [In]
APRON WIDTH AT BEGINING (W1) [ft]
APRON WIDTH AT END (W2) [ft]
4.00 2.00 4.00 5.00
17.5 17.5 17.5 17.5
3.0 1.5 3.0 3.8
5.7 2.8 5.7 7.1
Notes [1] Calculations performed in accordance with Hydraulic Engineering Circular No. 14, Third Edition; Hydraulic Design of Energy Dissipaters for Culverts and Channels, dated July 2006. [2] Pipe shall extend 1 foot into riprap. [3] For maximum pipe size of 60". JOB NO. JOB:
2836 CEC Solar #1206
283600SWM0001.xlsx
COMPUTED BY: DATE:
TJM 08/14/17
CHECKED BY: DATE:
Appendix E Site Owner’s Manual
SITE OWNER’S MANUAL CEC Solar #1206, LLC 147 Lumber Street Hopkinton, Massachusetts
Prepared for: CEC Solar #1144, LLC c/o Clean Energy Collective 146 West Boylston Drive, 3rd Floor Worcester, MA 01606
Presented by:
BEALS+THOMAS BEALS AND THOMAS, INC. Reservoir Corporate Center 144 Turnpike Road Southborough, MA 01772-2104
August 10, 2017
283600P002
CEC Solar #1206, LLC Site Owner’s Manual Hopkinton, Massachusetts 283600RP002
TABLE OF CONTENTS 1.0
INTRODUCTION .......................................................................................................................................... 1-1
2.0
SITE OWNER’S AGREEMENT ................................................................................................................. 2-1
2.1 2.2 2.3 2.4 3.0
LONG-TERM POLLUTION PREVENTION PLAN ................................................................................ 3-1
3.1 3.2 3.3 3.4 3.5 3.6 3.7 3.8 4.0
OPERATION AND MAINTENANCE COMPLIANCE STATEMENT........................................................................ 2-1 STORMWATER MAINTENANCE EASEMENTS ................................................................................................. 2-1 RECORD KEEPING ........................................................................................................................................ 2-1 TRAINING ..................................................................................................................................................... 2-2
STORAGE OF MATERIALS AND WASTE ......................................................................................................... 3-1 VEHICLE WASHING ...................................................................................................................................... 3-1 ROUTINE INSPECTIONS AND MAINTENANCE OF STORMWATER BMPS ......................................................... 3-1 SPILL PREVENTION AND RESPONSE .............................................................................................................. 3-1 VEGETATION MAINTENANCE PLAN.............................................................................................................. 3-1 STORAGE AND USE OF FERTILIZERS, HERBICIDES, AND PESTICIDES ............................................................ 3-2 SNOW REMOVAL PLAN ................................................................................................................................ 3-2 NUTRIENT MANAGEMENT PLAN .................................................................................................................. 3-2
LONG-TERM OPERATION AND MAINTENANCE PLAN ................................................................... 4-1
4.1 STORMWATER MANAGEMENT SYSTEM COMPONENTS ................................................................................. 4-1 4.2 INSPECTION AND MAINTENANCE SCHEDULES .............................................................................................. 4-1 4.2.1 Conveyance Swales ............................................................................................................................ 4-1 4.2.2 Infiltration Basins .............................................................................................................................. 4-2 4.2.3 Stormwater Outfalls ........................................................................................................................... 4-2 4.3 ESTIMATED OPERATION AND MAINTENANCE BUDGET ................................................................................ 4-3 4.4 PUBLIC SAFETY FEATURES .......................................................................................................................... 4-3
FIGURES FIGURE 1: SITE PLANS APPENDICES APPENDIX A: OPERATION AND MAINTENANCE LOG APPENDIX B: LIST OF EMERGENCY CONTACTS APPENDIX C: PROPRIETARY SEPARATOR TECHNICAL MANUAL
Table of Contents
i
CEC Solar #1206, LLC Site Owner’s Manual Hopkinton, Massachusetts 283600RP002
1.0
INTRODUCTION
The Site Owner’s Manual complies with the Long-Term Pollution Prevention Plan (Standard 4) and the Long-Term Operation and Maintenance Plan (Standard 9) requirements of the 2008 Massachusetts Department of Environmental Protection (DEP) Stormwater Handbook. The Manual outlines source control and pollution prevention measures and maintenance requirements of stormwater best management practices (BMPs) associated with the proposed development.
Introduction
1-1
CEC Solar #1206, LLC Site Owner’s Manual Hopkinton, Massachusetts 283600RP002
2.0
SITE OWNER’S AGREEMENT
2.1
Operation and Maintenance Compliance Statement Site Owner:
Clean Energy Collective 146 West Boylston Street, 3rd Floor Worcester, MA 01606
Responsible Party:
Clean Energy Collective
Clean Energy Collective or their successors shall maintain ownership of the on-site stormwater management system as well as the responsibility for operation and maintenance during the post-development stages of the project. The site has been inspected for erosion and appropriate measures have been taken to permanently stabilize any eroded areas. All aspects of stormwater best management practices (BMPs) have been inspected for damage, wear and malfunction, and appropriate steps have been taken to repair or replace the system or portions of the system so that the stormwater at the site may be managed in accordance with the Stormwater Management Standards. Future responsible parties shall be notified of their continuing legal responsibility to operate and maintain the BMPs. The operation and maintenance plan for the stormwater BMPs is being implemented. ___________________________ Responsible Party Signature
___________ Date
2.2
Stormwater Maintenance Easements There are no off-site areas utilized for stormwater control, therefore no stormwater management easements are required. The Site Owner will have access to all stormwater practices for inspection and maintenance, including direct maintenance access by heavy equipment to structures requiring regular maintenance.
2.3
Record Keeping The Site Owner shall maintain a rolling log in which all inspections and maintenance activities for the past three years shall be recorded. The Operation and Maintenance Log includes information pertaining to inspections, repairs, and disposal relevant to the project’s stormwater management system. The Log is located in Appendix A. The Operation and Maintenance Log shall be made available to the Conservation Commission and the DEP upon request. The Conservation Commission and the DEP shall be allowed to enter and inspect the premises to evaluate and ensure that the responsible party complies with the maintenance requirements for each BMP.
Site Owner’s Agreement
2-1
CEC Solar #1206, LLC Site Owner’s Manual Hopkinton, Massachusetts 283600RP002
2.4
Training Employees involved in grounds maintenance and emergency response will be educated on the general concepts of stormwater management and groundwater protection. The Site Owner’s Manual will be reviewed with the maintenance staff. The staff will be trained on the proper course of action for specific events expected to be incurred during routine maintenance or emergency situations.
Site Owner’s Agreement
2-2
CEC Solar #1206, LLC Site Owner’s Manual Hopkinton, Massachusetts 283600RP002
3.0
LONG-TERM POLLUTION PREVENTION PLAN
In compliance with Standard 4 of the 2008 DEP Stormwater Management Handbook, this section outlines source control and pollution prevention measures to be employed on-site after construction. 3.1
Storage of Materials and Waste The site shall be kept clear of trash and debris at all times. Certain materials and waste products shall be stored inside or outside upon an impervious surface and covered, as required by local and state regulations.
3.2
Vehicle Washing No commercial vehicle washing shall take place on site.
3.3
Routine Inspections and Maintenance of Stormwater BMPs See Section 4.0 Long-Term Operation and Maintenance Plan, for routine inspection and maintenance requirements for all proposed stormwater BMPs.
3.4
Spill Prevention and Response A contingency plan shall be implemented to address the spill or release of petroleum products and hazardous materials and will include the following measures: 1. Equipment necessary to quickly attend to inadvertent spills or leaks shall be stored on-site in a secure but accessible location. Such equipment shall include but not be limited to the following: safety goggles, chemically resistant gloves and overshoe boots, water and chemical fire extinguishers, sand and shovels, suitable absorbent materials, storage containers and first aid equipment (i.e. Indian Valley Industries, Inc. 55-gallon Spill Containment kit or approved equivalent). 2. Spills or leaks shall be treated properly according to material type, volume of spillage and location of spill. Mitigation shall include preventing further spillage, containing the spilled material in the smallest practical area, removing spilled material in a safe and environmentally-friendly manner, and remediation of any damage to the environment. 3. For large spills, Massachusetts DEP Hazardous Waste Incident Response Group shall be notified immediately at (617) 792-7653 and an emergency response contractor shall be consulted.
3.5
Vegetation Maintenance Plan See attached Solar Facility’s Operation and Maintenance Plan (Appendix C). Vegetated stormwater BMPs will be maintained as outlined in Section 4.0.
Long-Term Pollution Prevention Plan
3-1
CEC Solar #1206, LLC Site Owner’s Manual Hopkinton, Massachusetts 283600RP002
3.6
Storage and Use of Fertilizers, Herbicides, and Pesticides Fertilizers, herbicides, and pesticides will not be used at the proposed facility.
3.7
Snow Removal Plan See attached Solar Facility’s Operation and Maintenance Plan.
3.8
Nutrient Management Plan A nutrient management plan is required if a Total Maximum Daily Load (TMDL) has been developed that indicates that use of fertilizers containing nutrients or other specific pollutants must be reduced. The proposed project is located within the Upper/Middle Charles River watershed, which has a final TMDL issued for Phosphorous. As indicated in Section 3.6, fertilizers, herbicides, and pesticides will not be used at the proposed facility. Runoff generated onsite will be routed to infiltration basins for peak flow mitigation and treatment.
Long-Term Pollution Prevention Plan
3-2
CEC Solar #1206, LLC Site Owner’s Manual Hopkinton, Massachusetts 283600RP002
4.0
LONG-TERM OPERATION AND MAINTENANCE PLAN
This section outlines the stormwater best management practices (BMPs) associated with the proposed stormwater management system and identifies the long-term inspection and maintenance requirements for each BMP. 4.1
4.2
Stormwater Management System Components The following table outlines the type and quantity of the BMPs and their general location. Please reference the site plan(s) provided in the Figures section for exact location. All basins are accessible for maintenance from within the array. BMP Type
Quantity
Location
Conveyance Swale
1
Along eastern perimeter, to Basin 1.
Infiltration Basin
3
Basin 1 (northeastern corner of Site), Basin 2 (center of Site), & Basin 3 (western perimeter of Site)
Inspection and Maintenance Schedules 4.2.1
Conveyance Swales Conveyance swales shall be inspected and maintained as outlined below: •
• •
•
Swales shall be inspected during the first three months after installation to ensure vegetation is adequate and slopes are not eroding. All eroded areas shall be repaired and revegetated. Thereafter, swales shall be inspected once per year. During the inspection, swales shall be checked for: o Slope integrity o Soil moisture o Vegetative health o Soil stability o Soil compaction o Soil erosion o Ponding o Sedimentation Corrective measures shall be taken immediately as warranted by the inspections. The swales shall be mowed at least once per year. The vegetation shall be maintained at a length of 3-6 inches to ensure the effectiveness of the vegetation in reducing flow velocity and removing pollutants. Clippings shall be removed after each mowing. Sediment and debris shall be removed manually at least once per year.
Long-Term Operation and Maintenance Plan
4-1
CEC Solar #1206, LLC Site Owner’s Manual Hopkinton, Massachusetts 283600RP002
• •
4.2.2
If any evidence of hydrocarbons is found during inspection, the material shall be immediately removed using absorbent pads or other suitable measures and legally disposed. The swales shall be reseeded as necessary to maintain a dense growth of vegetation.
Infiltration Basins Infiltration basins shall be inspected and maintained after major storm events (rainfall totals greater than 2.5 inches in 24 hours) during the first three months of operation and twice a year and when there are discharges through the outlet control structure thereafter. Additionally, all pretreatment BMPs shall be inspected in accordance with the minimal requirements specified for those practices and after all major storm events. Inspections shall include the following measures: •
• • • •
During and after major storm events, the length of time standing water remains in the basin shall be recorded. o If the time is greater than 72 hours, thoroughly inspect the basin for signs of clogging. o A corrective action plan shall be developed by a qualified professional to restore infiltrative function. The Site Owner shall take immediate action to implement these corrective measures. Examine the outlet structure for evidence of clogging or outflow release velocities that are greater than the design velocity. Identify areas of sediment accumulation, differential settlement, cracking, and erosion within the basin. Inspect embankments for leakage and tree growth. Examine the health of the vegetation within the basin and on the embankments.
Corrective measures shall be taken immediately as warranted by the inspections. If any evidence of hydrocarbons is found during inspection, the material shall be immediately removed using absorbent pads or other suitable measures and legally disposed. Preventative maintenance shall include the following activities: • Mow the buffer area and basin bottom and side slopes, if vegetated. • Remove trash, debris, and accumulated organic matter. • Remove clippings after mowing. 4.2.3
Stormwater Outfalls Flared end sections and associated riprap spillways shall be inspected at least once per year and after major storm events (rainfall totals greater than 2.5
Long-Term Operation and Maintenance Plan
4-2
CEC Solar #1206, LLC Site Owner’s Manual Hopkinton, Massachusetts 283600RP002
inches in 24 hours) to ensure that the stability of the outlet area is maintained. The outfall area shall be kept clear of debris such as trash, branches, and sediment. Repairs shall be made immediately if riprap displacement or downstream channel scour is observed. 4.3
Estimated Operation and Maintenance Budget An operations and maintenance budget was prepared to approximate the annual cost of the inspections required in compliance with the DEP Stormwater Management Policy. The table below estimates the annual cost to inspect and maintain each proposed BMP, based on the requirements in Section 4.2. BMP Type Water Quality Swale Infiltration Basin Riprap Spillway Stormwater Outfalls
4.4
# of BMPS 1 3 3 6
Annual O&M Cost (per BMP) 1 $400-$800 $200 - $400 $50-$100 $50-$100 Total
Total Cost $400-$800 $600-$1,200 $150-$300 $300-$600
Public Safety Features The facility contains a perimeter fence and gates that will be locked to prevent unauthorized entry into the facility.
1
Annual maintenance cost is based on estimate of the cost to complete all inspection and maintenance measures outlined in Section 4.2. For BMPs that require sediment removal at regular intervals (i.e. every 5 or 10 years), the annual cost includes the annual percentage of that cost.
Long-Term Operation and Maintenance Plan
4-3
Figures Figure 1: Site Plans
Appendices
Appendix A Operation and Maintenance Log
CEC Solar #1206, LLC Operation and Maintenance Log Hopkinton, Massachusetts 283600RP002
OPERATION AND MAINTENANCE LOG This template is intended to comply with the operation and maintenance log requirements of the 2008 DEP Stormwater Management Handbook. Copies of this log should be made for all inspections and kept on file for three years from the inspection date. Name/Company of Inspector: Date/Time of Inspection: Weather Conditions: (Note current weather and any recent precipitation events)
Stormwater BMP
Inspection Observations
Actions Required
Appendix B List of Emergency Contacts
Emergency Contacts Massachusetts DEP Hazardous Waste Incident Response Group (617)792-7653 Town of Hopkinton Department of Public Works 66 Fruit Street Hopkinton, MA 01748 (508)497-9740 Town of Hopkinton Fire Department 73 Main Street Hopkinton, MA 01748 (508)497-2323 Town of Hopkinton Police Department 74 Main Street Hopkinton, MA 01748 (508)497-3401
Appendix F Stormwater Pollution Prevention Plan
283600RP003
August 10, 2017
BEALS AND THOMAS, INC. Reservoir Corporate Center 144 Turnpike Road Southborough, MA 01772-2104
BEALS+THOMAS
Prepared by:
T F A R D
CEC Solar #1206, LLC c/o Clean Energy Collective 146 West Boylston Drive, 3rd Floor Worcester, MA 01606
Prepared for:
147 Lumber Street Hopkinton, Massachusetts
CEC Solar #1206, LLC
EPA Construction General Permit
SITE EVALUATION, ASSESSMENT AND PLANNING ............................................4
OPERATOR(S)/ SUBCONTRACTORS ................................................................................... 1 STORMWATER TEAM........................................................................................................ 2
CONTACT INFORMATION/RESPONSIBLE PARTIES ...........................................1
EROSION AND SEDIMENT CONTROL BMPS ........................................................15
ENDANGERED SPECIES CERTIFICATION.......................................................................... 12 HISTORIC PRESERVATION .............................................................................................. 12 SAFE DRINKING WATER ACT UNDERGROUND INJECTION CONTROL REQUIREMENTS.... 13 APPLICABLE STATE OR LOCAL PROGRAMS .................................................................... 14
COMPLIANCE WITH APPLICABLE FEDERAL & STATE REQUIREMENTS 12
Table of Contents
i
4.1 NATURAL BUFFERS OR EQUIVALENT SEDIMENT CONTROLS .......................................... 15 4.2 MINIMIZE DISTURBED AREA AND PROTECT NATURAL FEATURES AND SOIL ................. 17 4.2.1 Preserve Existing Vegetation .................................................................................... 17 4.2.2 Stockpiling Topsoil.................................................................................................... 17 4.3 PHASED CONSTRUCTION ACTIVITY................................................................................ 17 4.3.1 Phase I ...................................................................................................................... 17
4.0
3.1 3.2 3.3 3.4
3.0
T F A R D
2.1 PROJECT/SITE INFORMATION ........................................................................................... 4 2.1.1 Emergency-Related Projects ....................................................................................... 5 2.2 NATURE AND SEQUENCE OF CONSTRUCTION ACTIVITY ................................................... 5 2.2.1 Function of the Construction Activity ......................................................................... 5 2.2.2 Building Demolition .................................................................................................... 5 2.2.3 Agricultural Land........................................................................................................ 5 2.2.4 Estimated Project Dates ............................................................................................. 5 2.3 SOILS, SLOPES, VEGETATION, AND CURRENT DRAINAGE PATTERNS ............................... 7 2.4 CONSTRUCTION SITE ESTIMATES ..................................................................................... 7 2.5 DISCHARGE INFORMATION............................................................................................... 8 2.5.1 Description of Receiving Storm Sewer Systems .......................................................... 8 2.5.2 Receiving Waters ........................................................................................................ 8 2.5.3 Impaired Waters/ TMDLs ........................................................................................... 8 2.5.4 Tier 2, 2.5, or 3 Waters ............................................................................................... 9 2.6 UNIQUE SITE FEATURES AND SENSITIVE AREAS .............................................................. 9 2.7 CONSTRUCTION SUPPORT ACTIVITIES.............................................................................. 9 2.7.1 Support Activity Site Information................................................................................ 9 2.7.2 Support Activity Contact Information ......................................................................... 9 2.8 POTENTIAL SOURCES OF POLLUTION ............................................................................... 9 2.8.1 Potential Sources of Sediment .................................................................................... 9 2.8.2 Potential Sources of Non-Sediment Pollutants ........................................................... 9 2.9 SITE PLANS .................................................................................................................... 11
2.0
1.1 1.2
1.0
TABLE OF CONTENTS
283600RP003
CEC Solar #1206, LLC Stormwater Pollution Prevention Plan (SWPPP) Hopkinton, Massachusetts
GOOD HOUSEKEEPING BMPS ..................................................................................23
6.0
Table of Contents
ii
POST-CONSTRUCTION BMPS ...................................................................................31
5.1 MATERIAL HANDLING AND WASTE MANAGEMENT ....................................................... 23 5.1.1 Solid or Construction Waste Disposal ...................................................................... 24 5.1.2 Recycling ................................................................................................................... 24 5.1.3 Sanitary and Septic Waste ........................................................................................ 25 5.1.4 Hazardous Materials and Waste............................................................................... 25 5.2 ESTABLISH PROPER BUILDING MATERIAL STAGING AREAS .......................................... 26 5.3 DESIGNATE WASHOUT AREAS ....................................................................................... 26 5.3.1 Concrete Washout ..................................................................................................... 26 5.3.2 Applicators, Containers and Paint Washout ............................................................ 27 5.4 ESTABLISH PROPER EQUIPMENT/VEHICLE FUELING AND MAINTENANCE PRACTICES ... 28 5.5 ALLOWABLE NON-STORMWATER DISCHARGES AND CONTROL EQUIPMENT / VEHICLE WASHING ................................................................................................................................... 28 5.6 SPILL PREVENTION AND CONTROL PROCEDURES ........................................................... 29 5.7 FERTILIZER DISCHARGE RESTRICTIONS ......................................................................... 29 5.8 ANY ADDITIONAL BMPS ............................................................................................... 30 5.9 ALLOWABLE NON-STORMWATER DISCHARGE MANAGEMENT ...................................... 30
5.0
T F A R D
INSPECTIONS AND MAINTENANCE .......................................................................34
PERMANENT SEEDING .................................................................................................... 32
FINAL STABILIZATION ..............................................................................................32
DETENTION BASIN ......................................................................................................... 31 INFILTRATION BASIN ..................................................................................................... 31 BIORETENTION AREA ..................................................................................................... 31 GRASS DRAINAGE CHANNELS........................................................................................ 31 INFILTRATION TRENCH .................................................................................................. 31 POROUS PAVERS ............................................................................................................ 31 TREE BOX FILTER .......................................................................................................... 31 DEEP SUMP AND HOODED CATCH BASINS AND WATER QUALITY STRUCTURES............ 31
T F A R D
RECORDKEEPING AND TRAINING .........................................................................36
10.1 10.2 10.3 10.4
10.0
Table of Contents
iii
SIGNATURE, PLAN REVIEW, AND MAKING PLANS AVAILABLE ...................................... 38 NOTICE OF PERMIT COVERAGE ........................................................................................ 38 OWNER CERTIFICATION ................................................................................................. 39 OPERATOR CERTIFICATION ............................................................................................ 40
CERTIFICATION AND NOTIFICATION ..................................................................38
9.1 RECORDKEEPING............................................................................................................ 36 9.2 LOG OF CHANGES TO THE SWPPP ................................................................................. 36 9.3 TRAINING ....................................................................................................................... 36 9.3.1 Individual(s) Responsible for Training ..................................................................... 36 9.3.2 Description of Training Conducted .......................................................................... 37
9.0
8.1 INSPECTIONS .................................................................................................................. 34 8.1.1 Inspection Schedule and Procedures ........................................................................ 34 8.2 REDUCTIONS IN INSPECTION FREQUENCY ...................................................................... 35 8.3 CORRECTIVE ACTION LOG ............................................................................................. 35
8.0
7.1
7.0
6.1 6.2 6.3 6.4 6.5 6.6 6.7 6.8
283600RP003
283600RP003
4.3.2 Phase II ..................................................................................................................... 17 4.4 CONTROL STORMWATER FLOWING ONTO AND THROUGH THE PROJECT........................ 17 4.4.1 Earth Dike ................................................................................................................. 17 4.4.2 Grass Drainage Channels......................................................................................... 17 4.5 STABILIZE SOIL .............................................................................................................. 18 4.5.1 Temporary Stabilization............................................................................................ 18 4.5.2 Mulching ................................................................................................................... 18 4.5.3 Permanent Stabilization ............................................................................................ 19 4.5.4 Dust Control ............................................................................................................. 19 4.6 PROTECT SLOPES ........................................................................................................... 19 4.6.1 Erosion Control Blanket ........................................................................................... 19 4.7 PROTECT STORM DRAIN INLETS .................................................................................... 19 4.7.1 Filter Bags ................................................................................................................ 19 4.8 ESTABLISH PERIMETER CONTROLS AND SEDIMENT BARRIERS ...................................... 20 4.8.1 Erosion Control Barrier ........................................................................................... 20 4.8.2 Silt Fence .................................................................................................................. 20 4.9 PREVENT SOIL COMPACTION ......................................................................................... 21 4.9.1 Protect Proposed Infiltration Areas.......................................................................... 21 4.10 RETAIN SEDIMENT ON-SITE ........................................................................................... 21 4.10.1 Temporary Sediment Basins ................................................................................. 21 4.11 ESTABLISH STABILIZED CONSTRUCTION ENTRANCE/EXIT............................................. 22 4.12 DEWATERING PRACTICES .............................................................................................. 22 4.13 ADDITIONAL BMPS ....................................................................................................... 23 4.13.1 BMP Name ............................................................................................................ 23
CEC Solar #1206, LLC Stormwater Pollution Prevention Plan (SWPPP) Hopkinton, Massachusetts
CEC Solar #1206, LLC Stormwater Pollution Prevention Plan (SWPPP) Hopkinton, Massachusetts
CONSTRUCTION GENERAL PERMIT
NOI AND ACKNOWLEDGEMENT LETTER FROM EPA
INSPECTION REPORTS
CORRECTIVE ACTION LOG
SWPPP AMENDMENT LOG
SUBCONTRACTOR CERTIFICATIONS/ AGREEMENTS
GRADING AND STABILIZATION ACTIVITIES LOG
TRAINING LOG
DELEGATION OF AUTHORITY
ENDANGARD SPECIES DOCUMENTATION
HISTORIC PRESERVATION DOCUMENTATION
TEMPORARY SEDIMENT BASIN SIZING CALCULATION
NATURAL BUFFER EQUIVALENCY CALCULATIONS
APPENDIX C:
APPENDIX D:
APPENDIX E:
APPENDIX F:
APPENDIX G:
APPENDIX H:
APPENDIX I:
APPENDIX J:
APPENDIX K:
APPENDIX L:
APPENDIX M:
APPENDIX N:
APPENDIX O:
Table of Contents
SITE PLANS
APPENDIX B:
T F A R D
GENERAL LOCATION MAP
APPENDIX A:
LIST OF APPENDICES
iv
283600RP003
CEC Solar #1206, LLC Stormwater Pollution Prevention Plan (SWPPP) Hopkinton, Massachusetts
Company:
Worcester
146 West Boylston Drive
TBD
MA
City:
TBD ZIP Code:
TBD
Name:
Telephone: TBD
TBD
Company:
24-Hour Emergency Contact
TBD
TBD
01606
Contact Information/Responsible Parties
Site Work Contractor
State:
Area of Control:
City:
Email: TBD
TBD
Address:
Email: TBD
TBD ZIP Code:
ZIP Code:
Telephone: TBD
TBD
TBD
Name:
Subcontractor Name
Company:
Subcontractor(s)
Telephone: TBD
TBD
TBD
Address:
State:
Email: TBD
State:
T F A R D TBD
Contractor Name
Name:
Company:
Telephone: TBD
City:
Address:
Name:
Clean Energy Collective
OPERATOR(S)/ SUBCONTRACTORS
1.1 Operator(s)
CONTACT INFORMATION/RESPONSIBLE PARTIES
1.0
1
1.2
Southborough
Address:
City:
MA
ZIP Code:
01772
Email: [email protected]
State:
TBD
TBD
TBD
City:
Telephone:
TBD
TBD
TBD
Company:
Name:
Address:
Inspection Personnel
TBD ZIP Code:
TBD
TBD
Contact Information/Responsible Parties
Email: TBD
State:
Email: TBD
TBD ZIP Code:
Telephone:
Address: State:
TBD
City:
TBD
TBD
Name:
TBD
Company:
T F A R D
2
Personnel Responsible for Installation & Maintenance of Stormwater BMPs
Telephone: 508-366-0560
Christopher Hale-Sills
144 Turnpike Road
Name:
Beals and Thomas, Inc.
Company:
SWPPP Preparer
STORMWATER TEAM
TBD TBD
Address: City: Telephone:
TBD ZIP Code: Email: TBD
State:
TBD
Contact Information/Responsible Parties
T F A R D
TBD TBD
Name:
TBD
Company:
Personnel Responsible for Taking Corrective Actions
3
Longitude:
-71.5308°
ZIP Code:
WGS 84 Unknown
01606
Yes
No
Site Evaluation, Assessment and Planning
NPDES project or permit tracking number: TBD
4
Are you applying for permit coverage as a “federal operator” as defined in Appendix A of the 2012 CGP? Yes No
Is this project considered a federal facility?
______________________________________________________
If yes, provide the name of the Indian tribe associated with the area of Indian country (including the name of Indian reservation if applicable), or if not in Indian country, provide the name of the Indian tribe associated with the property:
Is the project located on Indian country lands, or located on a property of religious of Yes No cultural significance to an Indian tribe?
Horizontal Reference Datum: NAD 27 NAD 83
T F A R D
Method for Determining Latitude/Longitude: USGS Topographic Map (specify scale: _________) EPA Website GPS Other (please specify): _Google Earth_______
42.2009°
Latitude:
MA
Middlesex
State:
County or Similar Subdivision:
Hopkinton
147 Lumber Street
Project Street/Location:
City:
CEC Solar #1206, LLC
PROJECT/SITE INFORMATION
2.1
Project/Site Name:
SITE EVALUATION, ASSESSMENT AND PLANNING
2.0
2.2
Yes
No
T F A R D
Yes
No
Site Evaluation, Assessment and Planning
Estimated Project Start Date: TBD Estimated Project Completion Date: TBD
2.2.4 Estimated Project Dates
2.2.3 Agricultural Land Was the pre-development land used for agriculture?
If yes, do any of the structures being demolished have at least 10,000 square feet Yes No of floor space?
2.2.2 Building Demolition Will there be demolition of any structure built or renovated before January 1, 1980? Yes No
Highway or Road Construction Other (please specify):_Solar Energy__
Institutional
Industrial
Multi-Family Residential
Utility
Commercial
Single-Family Residential
Function of the construction activity:
The project consists of the construction of a 6 MW solar energy facility within existing agricultural fields as well as in currently wooded areas.
2.2.1 Function of the Construction Activity
NATURE AND SEQUENCE OF CONSTRUCTION ACTIVITY
5
If yes, document the cause of the public emergency (e.g., natural disaster, extreme flooding conditions), information substantiating its occurrence (e.g., state disaster declaration), and a description of the construction necessary to reestablish effective public services:
Is this project in response to a public emergency?
2.1.1 Emergency-Related Projects
Construction Activity and BMP Descriptions
Before any site grading activities begin 1. Stake Limit of Construction. Workers shall be informed that no construction activity is to occur beyond this limit at any time. 2. Delineate the limit of the natural buffer to be maintained with flags, tape or other similar device. 3. Clear vegetation as necessary within the limits of construction. A stockpile of wood chips from tree cutting shall be left on site for stabilization. 4. Grub the areas where silt fence is required, removing stumps and roots as necessary. The existing ground surface shall be disturbed as little as possible prior to the start of construction. 5. Install silt fence and straw bales as shown on the plans. An adequate stockpile of erosion control materials shall be on site at all times for emergency or routine replacement and shall include materials to repair silt fences, straw bales, or any other devices planned for use during construction. 6. Construct stabilized construction exits. 7. Construct staging and materials storage area. 8. Install temporary sanitary facilities and dumpsters.
Date Start –Date End
Date Start –Date End
Site Evaluation, Assessment and Planning
6
Site grading 1. Begin site clearing and grubbing operations. 2. Commence excavation of stormwater management basins to act as temporary sedimentation basins during construction. 3. Commence construction of temporary drainage channels to direct runoff to sedimentation basin(s) during construction. Check dams shall be installed along the temporary drainage channels to reduce velocities and collect sediment. 4. Begin overall site grading and topsoil stripping. 5. Establish topsoil stockpile. 6. Install silt fences around stockpile and cover stockpiles. 7. Disturbed areas where construction will cease for more than 14 days shall be stabilized with erosion controls. Array Construction 1. Begin construction of Array. 2. Implement winter stabilization procedures.
T F A R D
Estimated Timeline of Activity Date Start –Date End
2.4
2.3
Final stabilization and landscaping 1. Convert temporary sediment basin(s) to (a) permanent infiltration basins. 2. Remove all temporary control BMPs and stabilize any areas disturbed by their removal with erosion controls 3. Prepare final seeding and landscaping. 4. Monitor stabilized areas until final stabilization is reached.
Total property area:
CONSTRUCTION SITE ESTIMATES
Site Evaluation, Assessment and Planning
TBD acres 7
Vegetation: The solar array is proposed within an area that is comprised of predominantly woodland vegetation. There is a portion of the property that is partially developed, and occupied by a single-family residence.
Drainage Patterns: The array is approximately centered on a high-point. Runoff from the site drains to the east and to the west. There are onsite bordering vegetated wetlands (BVW) at the eastern perimeter of the site as well as a potential vernal pool (PVP) and associated isolated vegetated wetland (IVW) at the southeastern quadrant. There is also a BVW at the western perimeter of the site (adjacent to Lumber Street). The resource areas at northeastern and western portions of the site ultimately flow to the north. The southeastern potion of the site (including the PVP and IVW) flows to the east and south.
Slopes: Slopes on site vary from 0% to 15%
T F A R D
Canton Fine Sandy Loam is a very deep, well drained soil on glaciated uplands. The typical soil profile is comprised of layers of fine sandy loam over gravelly fine sandy loam, over gravelly loamy sand. NRCS classifies these soils as Hydrologic Soil Group (HSG) “A” (extremely bouldery) & “B” (extremely stony). Narragansett Silt Loam, is a deep, well drained soil on glacial till plains and ground moraine. The typical soil profile is comprised of layers of silt loam over very gravelly loamy sand. NRCS classifies this soil as HSG “A”. Ridgebury Fine Sandy Loam, a very deep, poorly drained to somewhat poorly drained soil on glacial till uplands. The typical soil profile is comprised of layers of fine sandy loam over loamy fine sand, sand, and gravelly coarse sand. NRCS classifies this soil as HSG “D”.
Soil type(s): The Natural Resources Conservation Service (NRCS) Web Soil Survey lists the on-site soils as Canton Fine Sandy Loam, Narragansett Silt Loam, and some areas of Ridgebury Fine Sandy Loam.
SOILS, SLOPES, VEGETATION, AND CURRENT DRAINAGE PATTERNS
Date Start –Date End
2.5
TBD acres TBD % TBD TBD % TBD
Maximum area to be disturbed at one time:
Percentage impervious area before construction:
Runoff coefficient before construction:
Percentage impervious area after construction:
Runoff coefficient after construction:
2.8
Does your project/site discharge stormwater into a Municipal Separate Storm Sewer System (MS4)? Yes No
Yes
No
Yes
No
Site Evaluation, Assessment and Planning
List the pollutant(s) for which there is a TMDL: Phosphorus
8
If yes, list the title of the TMDL document: Total Maximum Daily Load for Nutrients in the Upper/Middle Charles River, Massachusetts
Has a TMDL been completed?
Describe the method(s) used to determine whether or not your project site discharges to an impaired water: Mass GIS Oliver mapping.
If yes, list the pollutant(s) causing the impairment: Phosphorus
Has the surface water been listed as “impaired?”
2.5.3 Impaired Waters/ TMDLs
Portions of the site drain to Echo Lake, which is a tier 2.5, or public water supply, which feeds the Charles River. Other portions of the site drain to Icehouse Pond, then Indian Brook, which feeds the Hopkinton Reservoir. A third portion of the site drains to Wildcat Pond, and then the Charles River.
2.5.2 Receiving Waters
2.7
2.6
2.5.1 Description of Receiving Storm Sewer Systems
T F A R D
DISCHARGE INFORMATION
TBD acres
Total construction site area to be disturbed:
Tier 2.5
Yes
Tier 3
No
T F A R D
Clearing and grubbing operations Grading and site excavation operations Vehicle tracking Topsoil stripping and stockpiling Landscaping operations
[2]
Fertilizer
Pesticides
Material/ Chemical
x
x
x
x
Chlorinated hydrocarbons, organophosphates, carbamates, arsenic Nitrogen, phosphorous
Various colored to colorless liquid, powder, pellets, or grains Liquid or solid grains
9
Herbicides used for noxious weed control Newly seeded areas
Location[1]
Site Evaluation, Assessment and Planning
Stormwater Pollutants
Physical Description
Combined Staging Area — small fueling activities, minor equipment maintenance, sanitary facilities, and hazardous waste storage. Materials Storage Area — general building materials, solvents, adhesives, paving materials, paints, aggregates, trash, and so on. Construction Activity — paving, curb/gutter installation, concrete pouring/mortar/stucco, and building construction Concrete Washout Area
2.8.2 Potential Sources of Non-Sediment Pollutants
x x x x x
2.8.1 Potential Sources of Sediment
POTENTIAL SOURCES OF POLLUTION
CONSTRUCTION SUPPORT ACTIVITIES Construction support activities are not required for the project.
There are onsite bordering vegetated wetlands (BVW) at the eastern perimeter of the site as well as a potential vernal pool (PVP) and associated isolated vegetated wetland (IVW) at the southeastern quadrant. There is also a BVW at the western perimeter of the site (adjacent to Lumber Street). The resource areas at northeastern and western portions of the site appear to ultimately flow to the north.
UNIQUE SITE FEATURES AND SENSITIVE AREAS
If yes specify which Tier the surface water is designated as: Tier 2
Is this surface water designated as a Tier 2, 2.5 or 3 water?
2.5.4 Tier 2, 2.5, or 3 Waters
Stoddard solvent, petroleum distillates, arsenic, copper, chromium
Naphtha
Metal oxides, stoddard solvent, talc, calcium carbonate, arsenic
Polymers, epoxies
Oil, petroleum distillates
Perchloroethylene, methylene chloride, trichloroethylene, petroleum distillates
Benzene, ethyl benzene, toluene, xylene, MTBE
Petroleum distillate, oil & grease, naphthalene, xylenes
Coal oil, petroleum distillates
Colorless, pale brown or pink petroleum hydrocarbon
Clear, blue-green to yellow liquid
Pale yellow liquid petroleum hydrocarbon
Gasoline
Diesel Fuel
Kerosene
Curb and gutter, walkways Timber pads and building construction Leaks or broken hoses from equipment Secondary containment/staging area Secondary containment/staging area Secondary containment/staging area Leaks or broken hoses from equipment
Building construction
Streets, parking areas, and roofing Building construction
No equipment cleaning allowed in project limits
Antifreeze/ coolant
Clear green/yellow liquid
Site Evaluation, Assessment and Planning
10
Ethylene glycol, propylene glycol, heavy metals (copper, lead, zinc) Sanitary Bacteria, parasites, and Various colored liquid Staging area toilets viruses [1] Area where material/chemical is used on-site. [2] Use of fertilizers containing nitrogen and/ or phosphorus in ratios greater than recommended by the manufacture must be documented.
Mineral oil
Brown oily petroleum hydrocarbon
Hydraulic oil/fluids
T F A R D
Clear amber or dark brown liquid
Various colored liquids
Paints
Wood preservatives
White or yellow liquid
Glue/ adhesives
Creamy white liquid
Black solid
Asphalt
Curing compounds
Colorless, blue, or yellow-green liquid
Cleaning solvents
2.9
T F A R D
See Appendix B: Site Plans
Site Evaluation, Assessment and Planning
Areas of federally-listed critical habitat for endangered or threatened species
11
Locations where polymers, flocculants, or other treatment chemicals will be used and stored
Locations of all pollutant-generating activities
Locations of storm drain inlets and stormwater control measures on the site and in the immediate vicinity of the site
Locations where stormwater discharges or allowable non-stormwater to surface water(s)
Boundary lines of any natural buffers,
Location of all waters of the U.S., including wetlands on or near the site. Indicate if water bodies are listed as impaired, or are identified as Tier 2, 2.5 or 3 waters.
Locations of off-site material, waste, borrow, or equipment storage areas
Locations [and timing] of stabilization measures
Location(s) of sediment, soil or other construction materials will be stockpiled
Locations of major structural and non-structural BMPs identified in the SWPPP
Natural features to be preserved
Direction(s) of stormwater flow and approximate slopes before and after major grading activities
Areas of soil disturbance and areas that will not be disturbed
Delineation of construction phasing, if applicable
These Site Plans include:
The Topographic Plan shows the undeveloped site and its current features. The Site Plans show the developed site.
SITE PLANS
3.2
ENDANGERED SPECIES CERTIFICATION
3.1
Compliance with Applicable Federal & State Requirements
If yes, provide documentation of the basis for your determination.
12
Step 3 If you answered no in Step 2, has it been determined that the installation of subsurface earth-disturbing stormwater controls will have no effect on historic properties? Yes No
Step 2 If you answered yes in Step 1, have prior surveys or evaluations conducted on the site already determined that historic properties do not exist, or that prior disturbances at the site have precluded the existence of historic properties? Yes No
Step 1 Will stormwater controls that require subsurface earth disturbance be installed on the site? Yes No
HISTORIC PRESERVATION
If yes, describe or refer to documentation that determines the likelihood of an impact on the identified species and/or habitat and the steps taken to address that impact.
If yes, describe the species and/or critical habitat:
T F A R D
Additionally, the NHESP Northern Long-eared Bat Locations in Massachusetts map, last updated March 24, 2016 was reviewed and it was determined that the Project does not occur within 0.25 miles of a known winter hibernacula or within a 150-foot radius of a known maternity roost tree. Therefore, no further review of potential impacts to Northern Long-eared Bat is required pursuant to the MESA.
Describe how this determination was made: The MASSGIS NHESP Priority Habitat of Rare Species Layer, Updated September, 2008, indicates that no priority habitat of rare species are located within the project site.
Are endangered or threatened species and critical habitats on or near the project area? Yes No
COMPLIANCE WITH APPLICABLE FEDERAL & STATE REQUIREMENTS
3.0
3.3
T F A R D
Compliance with Applicable Federal & State Requirements
13
If yes, attach documentation of contact between you and the applicable state agency or EPA Regional Office responsible for implementing the requirements for underground injection wells in the Safe Drinking Water Act and EPA’s implementing regulations at 40 CFR Parts 144-147.
Drywells, seepage pits, or improved sinkholes (if stormwater is directed to any bored, drilled, driven shaft or dug hole that is deeper than its widest surface dimension, or has a subsurface fluid distribution system)
Commercially manufactured pre-cast or pre-built proprietary subsurface detention vaults, chambers, or other devices designed to capture and infiltrate stormwater flow
Infiltration trenches (if stormwater is directed to any bored, drilled, driven shaft or dug hole that is deeper than its widest surface dimension, or has a subsurface fluid distribution system)
Do you plan to install any of the following controls?
SAFE DRINKING WATER ACT UNDERGROUND INJECTION CONTROL REQUIREMENTS
Other:
No agreement has been reached regarding measures to mitigate effects to historic properties from the installation of stormwater controls.
Written indication that adverse effects to historic properties from the installation of stormwater controls can be mitigated by agreed upon actions.
If no, no further documentation is required. If yes, describe the nature of their response and include documentation in the Appendix:
Step 4 If you answered no in Step 3, did the State Historic Preservation Officer (SHPO), Tribal Historic Preservation Office (THPO), or other tribal representative (whichever applies) respond within 15 calendar days to indicate whether the subsurface earth disturbances caused by the installation of stormwater controls affect historic properties? Yes No
3.4
Compliance with Applicable Federal & State Requirements
T F A R D
14
A plan to control construction-related impacts, including erosion, sedimentation, and other pollutant sources during construction and land disturbance activities (construction period erosion, sedimentation, and pollution prevention plans) shall be developed and implemented.
NATURAL BUFFERS OR EQUIVALENT SEDIMENT CONTROLS
Natural Buffers or Equivalent Sediment Controls Minimize disturbed area and protect natural features and soil Control stormwater flowing onto and through the project Stabilize soils Protect slopes Establish perimeter controls and sediment barriers Retain sediment on-site and control dewatering practices Establish stabilized construction exits
Good Housekeeping BMPs
15
It is infeasible to provide and maintain an undisturbed natural buffer of any size, therefore erosion and sediment controls will be implemented that achieve the sediment load reduction equivalent to a 50-foot undisturbed natural buffer. The estimated
Description of Controls: Provide a description of the additional erosion and sediment controls proposed, including the model or other tool used to estimate the sediment load reductions and the results from the calculation.
An undisturbed natural buffer of xx-feet will be provided along with supplemental erosion and sediment controls, which in combination achieves the sediment load reduction equivalent to a 50-foot undisturbed natural buffer. The estimated sediment removal calculations are included in the appendixes of this report and have been calculated using the applicable tables included in Appendix G of the 2012 Construction General Permit or site-specific calculations were performed to estimate the sediment removal of a 50-buffer zone and the efficiency of the reduced buffer zone and supplemental erosion control measures.
A 50-foot undisturbed natural buffer will be maintained. The 50-foot buffer is shown on the attached site plans and will be clearly marked off with flags, tape, or a similar marking device prior to the commencement of earth disturbing activities.
If yes, check the compliance alternative that applies:
Are there any surface waters located within 50 feet of your construction disturbances that receive stormwater discharges from the site? Yes No
4.1
x x x x x x x x
This SWPPP contains a listing of the erosion and sediment control best management practices (BMPs) that will be implemented to control pollutants in stormwater discharges. The BMPs are categorized under one of the areas of BMP activity as described below:
This SWPPP complies with the requirements of Standard 8 of the Massachusetts Department of Environmental Protection Stormwater Handbook, which states:
EROSION AND SEDIMENT CONTROL BMPS
4.0
APPLICABLE STATE OR LOCAL PROGRAMS
Good Housekeeping BMPs
16
Buffer disturbances will occur for the construction of a water-dependent structure or water access area (e.g., pier, boat ramp, and trail).
Buffer disturbances are authorized under a CWA Section 404 permit.
Alternative 2: A sediment discharge risk evaluation has been prepared and is included in the appendices of this report.
Alternative 1: A [select one: 50-foot buffer, a buffer <50 feet and > 30 has been provided with double perimeter controls buffer less than 30-feet has been provided with double perimeter controls with 7-day site stabilization requirements has been provided.] Provide a description on how the controls will comply with the CGP requirements.
The project qualifies as “small residential lot” construction, and complies with:
For a “linear project,” site constraints (e.g., limited right-of-way) make it infeasible for the site to meet any of the CGP Part 2.1.2.1.a compliance alternatives
No natural buffer exists due to preexisting development disturbances, such as impervious surfaces or structures that were constructed prior to the initiation of planning for this project.
There is no discharge of stormwater to surface waters through the area between the disturbed portions of the site and any surface waters located within 50 feet of the site. This includes situations where control measures have been implemented such as a berm or other barrier that will prevent such discharges.
T F A R D
The project qualifies for one of the exceptions in Part 2.1.2.1.e. of the 2012 Construction General Permit. Specifically:
Description: Include rationale for why a natural buffer cannot be maintained. Provide a description of the additional erosion and sediment controls proposed, including the model or other tool used to estimate the sediment load reductions and the results from the calculation. Include the estimated sediment removal rate from a natural 50-buffer and the proposed controls.
sediment removal calculations are included in the appendixes of this report and have been calculated using the applicable tables included in Appendix G of the 2012 Construction General Permit or site-specific calculations were performed to estimate the sediment removal of a 50-buffer zone and the efficiency of the reduced buffer zone and supplemental erosion control measures.
4.3
4.2
Design Specifications
Maintenance and Inspection:
Installation Schedule:
Description:
Good Housekeeping BMPs
17
A grass drainage channel shall be installed at location, as indicated on the site plans. The channel shall convey runoff to storm drain inlets and temporary sediment basins, as appropriate or at locations shown on plans. Some grass drainage channels shall remain as a permanent stormwater structure after construction is complete. The grass drainage channel shall be installed after clearing and grubbing operations are completed at the site. The channel shall be inspected weekly and immediately after storm events for erosion and structural failures. Before vegetation has been established in the channel, inspect erosion control blankets, embankments, and beds for erosion and accumulation of debris and sediment. Remove debris, sediment, and repair erosion control blankets, fiber rolls and embankments immediately.
4.3.1 Grass Drainage Channels
CONTROL STORMWATER FLOWING ONTO AND THROUGH THE PROJECT
Topsoil stripped from the immediate construction area shall be stockpiled as identified on the Site Plans and Sitework Specifications or as approved by the SWPPP preparer. Stockpiles shall be located outside of any natural buffers and away from any stormwater conveyances, drain inlets, and areas where stormwater flow is concentrated. Installation Topsoil stockpiles shall be established during grading activities. Schedule: The silt fence and temporary erosion controls shall be installed immediately after the stockpile has been established. For piles that will be unused for 14 or more days provide cover over the stockpile or temporary stabilization to avoid direct contract with precipitation and wind. Install a sediment barrier along all downgradient perimeter areas of stockpiles. Maintenance The area shall be inspected weekly for erosion and immediately after and storm events. Areas on or around the stockpile that have eroded shall Inspection: be stabilized immediately with erosion controls. See following Silt Fence section for Maintenance and inspection procedures.
Description:
4.2.1 Stockpiling Topsoil
MINIMIZE DISTURBED AREA AND PROTECT NATURAL FEATURES AND SOIL
4.4
Initiation of temporary vegetative cover shall occur immediately where construction will cease for more that 7 days. It shall be established using hydroseeding for areas of exposed soil (including stockpiles). Temporary stabilization measures shall be initiated immediately where construction activities will temporarily cease for more than 14 days. Stabilized areas shall be inspected weekly and after storm events until a dense cover of vegetation has become established. If failure is noticed at the seeded area, the area shall be reseeded, fertilized, and mulched immediately.
Maintenance and Inspection:
Good Housekeeping BMPs
18
Hydromulching shall provide immediate protection to exposed soils during short periods of disturbance. Hydromulch shall also be applied in areas that have been seeded for temporary or permanent stabilization. Hydromulch shall be applied to exposed soils during short periods of construction and seeded areas. Mulched areas shall be inspected weekly and after storm events to check for movement of mulch or erosion. If washout, breakage, or erosion occurs, the surface shall be repaired, and new mulch shall be applied to the damaged area.
T F A R D
Installation Schedule:
Description:
4.4.2 Mulching
Maintenance and Inspection:
Installation Schedule:
Description:
4.4.1 Temporary Stabilization
STABILIZE SOIL
1. The channel shall have a positive drainage to convey runoff to the storm drain inlets and temporary sediment basins.
Maintenance and Inspection:
Installation Schedule:
Description:
4.4.4 Dust Control
Initiation of permanent stabilization measures shall occur immediately after the final design grades are achieved and earth moving activities cease. Native species of plants shall be used to establish vegetative cover on exposed soils. Permanent stabilization shall be completed in accordance with the procedures outlined in the Final Stabilization section of this report. Portions of the site where construction activities have permanently ceased shall be stabilized, as soon as possible. All seeded areas shall be inspected weekly during construction activities and after storm events until a dense cover of vegetation has been established. If failure is noticed at the seeded area, the area shall be reseeded, fertilized, and mulched immediately. Care shall be taken to avoid compacting newly placed topsoil. After construction is completed at the site, permanently stabilized areas shall be monitored until final stabilization is reached.
Good Housekeeping BMPs
19
Dust from the site shall be controlled by using a mobile pressure-type distributor truck to apply water to disturbed areas. The mobile unit shall apply water at a rate of 300 gallons per acre and minimized as necessary to prevent runoff and ponding. Dust control shall be implemented as needed once site grading has been initiated and during windy conditions (forecasted or actual wind conditions of 20 mph or greater) while site grading is occurring. Spraying of water shall be performed no more than three times a day during the months of May–September and once per day during the months of October–April or whenever the dryness of the soil warrants it. At least one mobile unit shall be available at all times to distribute water to control dust on the project area. Each mobile unit shall be equipped with a positive shutoff valve to prevent over watering of the disturbed area.
T F A R D
Maintenance and Inspection:
Installation Schedule:
Description:
4.4.3 Permanent Stabilization
4.5
Good Housekeeping BMPs
20
Temporary Entrenched silt fence shall be installed to decrease the velocity of sheet flows and intercept and detain small amounts of sediment from disturbed areas. Installation Schedule: Silt fence shall be installed prior to clearing and grubbing. Maintenance and Silt fence shall be inspected weekly, following storms, and Inspection: daily during rainy periods. Damaged fencing shall be replaced. Concentrated flows shall be intercepted and rerouted. Sediment accumulations shall be removed when reaching a depth of 6-inches. Deteriorated fencing material shall be replaced. Used fencing shall be properly disposed of.
Permanent Description:
4.5.2 Silt Fence
T F A R D
Temporary An erosion control barrier, consisting of entrenched straw bales, straw wattles, compost socks and siltation fencing, shall be installed along the downgradient side of the proposed project to decrease the velocity of sheet flows and intercept and detain small amounts of sediment from disturbed areas. Installation Schedule: Erosion Control Barrier shall be installed prior to clearing and grubbing. Maintenance and Erosion Control Barrier shall be inspected weekly, Inspection: following storms, and daily during rainy periods. Damaged fencing shall be replaced. Concentrated flows shall be intercepted and rerouted. Sediment accumulations shall be removed when reaching a depth of 6-inches, or one-half of the above ground height of the barrier, whichever is less. Deteriorated fencing material shall be replaced. Used fencing shall be properly disposed of.
Permanent Description:
4.5.1 Erosion Control Barrier
ESTABLISH PERIMETER CONTROLS AND SEDIMENT BARRIERS
4.7
4.6
Good Housekeeping BMPs
21
Temporary Temporary sediment basins are located throughout the site between construction and wetland resource areas. These basins provide 3,600 cubic feet of storage per acre drained, as required by the EPA. Refer to the Temporary Sediment Basin Sizing Calculation located in Appendix K. Several temporary sediment basins will be utilized as sediment forebays following construction. Installation Schedule: Temporary Sediment Basins shall be installed during grading activities. Maintenance and Temporary Sediment Basins shall be inspected weekly and Inspection: following storms. Sediment shall be removed when it reaches a depth of one foot, or half the design capacity whichever is less. Damage to basin embankments and slopes shall be repaired.
Permanent Description:
4.7.1 Temporary Sediment Basins
RETAIN SEDIMENT ON-SITE
T F A R D
Temporary An erosion control barrier, consisting of entrenched straw bales and siltation fencing, shall be installed around the perimeter of all proposed infiltration areas to prevent construction vehicles from impacting the area, to decrease the velocity of sheet flows and intercept, and detain small amounts of sediment from disturbed areas. Installation Schedule: The erosion control barrier shall be installed after clearing and grubbing. Maintenance and Silt fence shall be inspected weekly, following storms, and Inspection: daily during rainy periods. Damaged fencing shall be replaced. Concentrated flows shall be intercepted and rerouted. Sediment accumulations shall be removed when reaching a depth of 6-inches. Deteriorated fencing material shall be replaced. Used fencing shall be properly disposed of.
Permanent Description:
4.6.1 Protect Proposed Infiltration Areas
PREVENT SOIL COMPACTION
4.9
4.8
Description:
DEWATERING PRACTICES
x x
Good Housekeeping BMPs
22
Visible floating solids or foam shall not be discharged; An oil-water separator or suitable filtration device (such as a cartridge filter) that is designed to remove oil, grease, or other products if dewatering water is found to contain these materials shall be used;
All groundwater or stormwater discharged from excavations, trenches, foundations, vaults, or other similar point shall be treated by sediment basins, sediment traps, sediment socks, dewatering tanks, tube settlers or filtration systems specifically designed to remove sediment from the excavations. All dewatering practices shall conform to the following:
T F A R D
Temporary Temporary gravel or crushed stone construction entrances/exits or other means shall be used to minimize off-site movement of soil with vehicles. Construction access points shall be maintained to minimize tracking of soil onto public roads and existing parking lots to remain. If the rock entrance is not working to keep streets clean, then install wheel wash, sweep streets, or wash streets if wash water can be collected. Installation Schedule: Stabilized construction entrance shall be installed prior to clearing and grubbing. Maintenance and Stabilized construction entrances shall be inspected daily. Inspection: Gravel or crushed stone shall be added if the pad is no longer in accordance with the specifications. If the rock entrance is not working to keep streets clean, then install wheel wash, sweep streets, or wash streets if wash water can be collected. When sediment has been tracked off of the site, it shall be removed by the end of the same working day, or by the end of the next working day if track-out occurs on a non work day. Remove sediment by sweeping, shoveling or vacuuming roadways were sediment has been tracked-out.
Permanent Description:
ESTABLISH STABILIZED CONSTRUCTION ENTRANCE/EXIT
GOOD HOUSEKEEPING BMPS
5.1
Material Handling and Waste Management Establish Proper Material Staging Areas Designate Washout Areas Establish Proper Equipment/Vehicle Fueling and Maintenance Practices Allowable Non-Stormwater Discharges and Control Equipment/Vehicle Washing Spill Prevention and Control Plan
Good Housekeeping BMPs
23
Several management procedures and practices are proposed to prevent and/or reduce the discharge of pollutants to stormwater from solid or liquid wastes that will be generated at the site. These measures are grouped into the following categories: (1) solid or construction waste disposal, (2) recycling, (3) sanitary and septic waste, and (4) hazardous materials.
MATERIAL HANDLING AND WASTE MANAGEMENT
x x x x x x
This SWPPP contains a listing of the good housekeeping best management practices (BMPs) that shall be implemented to control pollutants in stormwater discharges during construction-related work. The BMPs are categorized below:
5.0
Maintenance and Inspection:
Installation Schedule:
To the extent feasible, utilize vegetated, upland areas of the site to infiltrate dewatering water before discharge. In no case will surface waters be considered part of the treatment area; x Velocity dissipaters shall be installed at all points where dewatering activities are discharged to the surface. x With backwash water, either haul it away for disposal or return it to the beginning of the treatment process; and x Replace and clean the filter media used in dewatering devices when the pressure differential equals or exceeds the manufacturer’s specifications. Install settling or filtration methods prior to commencing dewatering. Engineer is required to provide or approve settling of filtration method design prior to installation. Settling of filtration controls shall be inspected weekly and following storms. Sediment shall be removed when it reaches a depth of one foot, or half the design capacity whichever is less.
x
Installation Schedule: Maintenance and Inspection:
Description:
5.1.2 Recycling
Good Housekeeping BMPs
24
Wood pallets, cardboard boxes, and other recyclable construction scraps shall be disposed of in a designated dumpster for recycling. The dumpster shall have a secure watertight lid, be placed away from stormwater conveyances and drains and meet all local and state solid-waste management regulations. Only solid recyclable construction scraps from the site shall be deposited in the dumpster. All personnel shall be instructed regarding the correct procedure for disposal of recyclable construction scraps. Notices that state these procedures shall be posted in the office trailer, and the individual who manages day-to-day site operations shall be responsible for seeing that these procedures are followed. Designated recycling dumpsters shall be installed once the area has been established. The recycling dumpster shall be inspected weekly and immediately after storm events. The recycling dumpster shall be emptied weekly and taken to an approved recycling center. If recyclable
T F A R D
All waste materials shall be collected and disposed of into metal trash dumpsters in the materials storage area. Dumpsters shall have a secure watertight lid, be placed away from stormwater conveyances and drains, and meet all federal, state, and municipal regulations. Only trash and construction debris from the site shall be deposited in the dumpster. No construction materials shall be buried on-site unless authorized by a program for recycling/beneficial use. All personnel shall be instructed regarding the correct disposal of trash and construction debris. Notices that state these practices shall be posted in the office trailer and the individual who manages daytoday site operations shall be responsible for seeing that these practices are followed. Installation Trash dumpsters shall be installed once the materials storage area Schedule: has been established. Maintenance The dumpsters shall be inspected weekly and immediately after and storm events. The dumpsters shall be emptied weekly and taken to Inspection: an approved landfill or recycling facility. If trash and construction debris are exceeding the dumpsters’ capacity, the dumpsters shall be emptied more frequently. Waste container lids shall be closed when not in use and at the end of the business day. For waste containers that do not have lids, provide cover or a similarly effective means to minimize the discharge of pollutants.
Description:
5.1.1 Solid or Construction Waste Disposal
T F A R D
Temporary sanitary facilities (portable toilets) shall be provided at the site throughout the construction phase. The portable toilets shall be located in the staging area, away from concentrated flow paths and traffic flow. The portable toilets shall be brought to the site once the staging area has been established. All sanitary waste shall be collected from the portable facilities on a regular basis. The portable toilets shall be inspected weekly for evidence of leaking holding tanks. Toilets with leaking holding tanks shall be removed from the site and replaced with new portable toilets.
Installation Schedule: Maintenance and Inspection:
Description:
Good Housekeeping BMPs
25
All hazardous waste materials such as oil filters, petroleum products, paint, and equipment maintenance fluids shall be stored in structurally sound and sealed shipping containers, within the hazardous materials storage area. Hazardous waste materials shall be stored in appropriate and clearly marked containers and segregated from other non-waste materials. Secondary containment shall be provided for all waste materials in the hazardous materials storage area and shall consist of commercially available spill pallets. Additionally, all hazardous waste materials shall be disposed of in accordance with federal, state, and municipal regulations. Hazardous waste materials shall not be disposed of into the on-site dumpsters. All personnel shall be instructed regarding proper procedures for hazardous waste disposal. Notices that state these procedures shall be posted in the office trailer and the individual who manages day-to-day site operations shall be responsible for seeing that these procedures are followed. Shipping containers used to store hazardous waste materials shall be installed once the site materials storage area has been installed. The hazardous waste material storage areas shall be inspected weekly and after storm events. The storage areas shall be kept clean, well organized, and equipped with ample cleanup supplies as appropriate for the materials being stored. Material safety data sheets, material inventory, and emergency contact numbers shall be maintained in the office trailer.
5.1.4 Hazardous Materials and Waste
Installation Schedule: Maintenance and Inspection:
Description:
5.1.3 Sanitary and Septic Waste
construction wastes are exceeding the dumpsters’ capacity, the dumpsters shall be emptied more frequently.
5.3
5.2
All fertilizers, herbicides, insecticides and pesticides shall be stored in accordance with local, state, and federal regulations. At a minimum these materials shall be covered with plastic sheeting or a temporary roof to prevent contact with rainwater.
T F A R D
All hazardous-waste materials such as oil filters, petroleum products, paint, and equipment maintenance fluids shall be stored in structurally sound and sealed containers under cover within the storage area.
Construction equipment and maintenance materials shall be stored at the combined staging area and materials storage areas. A watertight shipping container shall be used to store hand tools, small parts, and other construction materials. Nonhazardous building materials such as packaging material (wood, plastic, and glass), and construction scrap material (brick, wood, steel, metal scraps, and pipe cuttings) shall be stored in a separate covered storage facility adjacent to the shipping container.
Description:
Good Housekeeping BMPs
26
A designated temporary, above-grade concrete washout area shall be constructed. The temporary concrete washout area shall be constructed with a recommended minimum length and minimum width of 10 feet, but with sufficient quantity and volume to contain all liquid and concrete waste generated by washout operations. The washout area shall be lined with plastic sheeting at least 10 mils thick and free of any holes or tears. Signs shall be posted marking the location of the washout area to ensure that concrete equipment operators use the proper facility.
5.3.1 Concrete Washout
DESIGNATE WASHOUT AREAS
Very large items, such as framing materials and stockpiled lumber, shall be stored in the open in the materials storage area. Such materials shall be elevated on wood blocks to minimize contact with runoff. Installation The materials storage area shall be installed after grading and before any Schedule: infrastructure is constructed at the site. Maintenance The storage area shall be inspected weekly and after storm events. The and storage area shall be kept clean, well organized, and equipped with ample Inspection: cleanup supplies as appropriate for the materials being stored. Perimeter controls, containment structures, covers, and liners shall be repaired or replaced as needed to maintain proper function.
Description:
ESTABLISH PROPER MATERIAL STAGING AREAS
T F A R D Installation Schedule:
Description:
Good Housekeeping BMPs
27
A designated temporary, above-grade washout area shall be constructed as needed for the washout and cleanout of stucco, paint, or other non-hazardous construction materials. The temporary washout area shall be a leak-proof container with sufficient volume to contain all liquid and waste generated by washout operations. The temporary washout shall be sited outside of all buffer zones. The washout area shall be constructed as needed.
5.3.2 Applicators, Containers and Paint Washout
Design Specifications: 1. Temporary concrete washout type Above Grade shall be constructed as shown above, with a recommended minimum length and minimum width of 10 feet. 2. The washout shall be a minimum of 50 feet from storm drain inlets. 3. Plastic lining shall be free of holes, tears, or other defects that compromise the impermeability of the material.
Installation Schedule: Maintenance and Inspection:
Concrete pours shall not be conducted during or before an anticipated storm event. Concrete mixer trucks and chutes shall be washed in the designated area or concrete wastes shall be properly disposed of off-site. When the temporary washout area is no longer needed for the construction project, the hardened concrete and materials used to construct the area shall be removed and disposed of according to the maintenance section below, and the area shall be stabilized. The washout area shall be constructed before concrete pours occur at the site. The washout areas shall be inspected daily to ensure that all concrete washing is being discharged into the washout area, no leaks or tears are present, and to identify when concrete wastes need to be removed. The washout areas shall be cleaned out once the area is filled to 75 percent of the holding capacity. Once the area’s holding capacity has been reached, the concrete wastes shall be allowed to harden; the concrete shall be broken up, removed, and taken to an approved landfill for disposal or recycled on-site or offsite in accordance with applicable laws. The plastic sheeting shall be replaced if tears occur during removal of concrete wastes from the washout area.
5.5
5.4
Description:
DISCHARGES
AND
CONTROL
Good Housekeeping BMPs
28
All equipment and vehicle washing shall be performed off-site, except as required for wheel washes and concrete washout areas.
ALLOWABLE NON-STORMWATER EQUIPMENT / VEHICLE WASHING
Several types of vehicles and equipment will likely be used on-site throughout the project, including graders, scrapers, excavators, loaders, paving equipment, rollers, trucks and trailers, backhoes, and forklifts. All major equipment/vehicle fueling and maintenance shall be performed outside of wetland buffer zones. When vehicle fueling must occur on-site, the fueling activity shall occur in the staging area. Only minor equipment maintenance shall occur on-site. All equipment fluids generated from maintenance activities shall be disposed of into designated drums stored on spill pallets in accordance with the Material Handling and Waste Management Section. Absorbent, spill-cleanup materials and spill kits shall be available at the combined staging and materials storage area. Drip pans shall be placed under all equipment receiving maintenance and vehicles and equipment parked overnight. Installation BMPs implemented for equipment and vehicle maintenance and fueling Schedule: activities shall begin at the start of the project. Maintenance Inspect equipment/vehicle storage areas weekly and after storm events. and Vehicles and equipment shall be inspected on each day of use. Leaks shall Inspection: be repaired immediately, using dry cleanup measures where possible and eliminating the source of the discharge. Problem vehicle(s) or equipment shall be removed from the project site. Keep ample supply of spill-cleanup materials on-site and immediately clean up spills and dispose of materials properly. Do not clean surfaces by hosing-down the area
Description:
T F A R D
The washout areas shall be inspected daily to ensure that all washing is being discharged into the washout area, no leaks or tears are present, and to identify when wastes need to be removed. The washout areas shall be cleaned out once the area is filled to 75 percent of the holding capacity. Liquid wastes shall be disposed of in accordance with applicable Federal and State requirements and shall not be discharged into drainage systems.
ESTABLISH PROPER EQUIPMENT/VEHICLE FUELING AND MAINTENANCE PRACTICES
Maintenance and Inspection:
5.7
5.6
T F A R D Description:
Good Housekeeping BMPs
29
Discharges from fertilizers containing nitrogen and phosphorus shall be minimized. Fertilizers shall be applied at rates and amounts consistent with the manufacture’s specification, and shall at no time exceed local, state, or federal specifications. See project landscape specifications for acceptable fertilizers that can be used for the project.
FERTILIZER DISCHARGE RESTRICTIONS
i.
Employee Training: All employees shall be trained as detailed in the Inspection and Maintenance section of this report. ii. Vehicle Maintenance: Vehicles and equipment shall be maintained off-site. All vehicles and equipment including subcontractor vehicles shall be checked for leaking oil and fluids. Vehicles leaking fluids shall not be allowed on-site. iii. Hazardous Material Storage: Hazardous materials shall be stored in accordance with this report and federal and municipal regulations. iv. Spill Kits: Spill kits shall be kept within the materials storage area. Spills: All spills shall be cleaned up immediately upon discovery. Spent absorbent materials and rags shall be hauled off-site immediately after the spill is cleaned up for disposal at an approved landfill. Spills large enough to discharge to surface water shall be reported to the National Response Center at 1-800-424-8802 and MA DEP at 617-792-7653. v. Material safety data sheets: A material inventory and emergency contact information shall be maintained at the on-site project trailer. Installation The spill prevention and control procedures shall be implemented once Schedule: construction begins on-site. Maintenance All personnel shall be instructed the correct procedures for spill prevention and and control. Notices that state these practices shall be posted in the office Inspection: trailer, and the individual who manages day-to-day site operations shall be responsible for seeing that these procedures are followed.
Description:
SPILL PREVENTION AND CONTROL PROCEDURES
Installation N/A Schedule: Maintenance N/A and Inspection:
x x x x x x x x x
Water Used to Control Dust Uncontaminated Excavation Dewatering Landscape Irrigation Fire Hydrant Flushing Firefighting Potable Water including uncontaminated waterline flushing Non-Detergent Laden Vehicle Wash Water Foundation or Footing Drains Uncontaminated air conditioning or compressor condensate
The following is a list of allowable non-stormwater discharges:
T F A R D
Good Housekeeping BMPs
30
Any changes in construction activities that produce other allowable non-stormwater discharges shall be identified, and the SWPPP shall be amended and the appropriate erosion and sediment control shall be implemented.
ALLOWABLE NON-STORMWATER DISCHARGE MANAGEMENT
Except for water used to control dust and irrigation water, the above discharges shall not be routed to areas of exposed soil.
5.8
Fertilizers shall be applied at an appropriate time of year, timed to coincide as closely as possible to the period of maximum vegetation uptake and growth. Avoid applying fertilizers before heavy rains. Do not apply fertilizers to frozen ground or stormwater conveyance channels flowing with water. Maintenance N/A and Inspection:
Installation Schedule:
6.2
T F A R D
The basins shall be inspected weekly and after storm events greater than 0.5 inches during construction. The area shall be checked for signs of erosion, seepage, and structural damage. Erosion, seepage, and structural damage shall be repaired immediately. The temporary sediment riser shall be checked for any damage or obstructions and any damage found shall be repaired and obstructions removed. Immediately after the completion of construction, the plant material shall be watered for 14 consecutive days unless there is sufficient natural rainfall. The area shall be monitored until final stabilization is reached. Following completion of site construction and final stabilization, maintenance and inspection responsibilities shall be taken over by the Owner in accordance with the Long-Term Pollution Prevention Plan and Long-Term Operation & Maintenance Plan.
Infiltration basins shall be excavated during earthwork construction.
Design Specifications: Installation Schedule: Maintenance and Inspection:
Description:
Final Stabilization
31
See Section 5 for maintenance and inspection procedures for the grass drainage channel. Following completion of site construction and final stabilization, maintenance and inspection responsibilities shall be taken over by the Owner in accordance with the Long-Term Pollution Prevention Plan and Long-Term Operation & Maintenance Plan.
Grass drainage channels shall be installed before site grading begins.
Some of the grass drainage channels shall remain as a permanent stormwater management structures for the site. The channels shall convey runoff to stormwater inlets throughout the site. Install according to sitework specifications and details.
GRASS DRAINAGE CHANNELS
Design Specifications: Installation Schedule: Maintenance and Inspection:
Infiltration basins shall be protected from stormwater runoff from the disturbed site during construction. Riprap spillways shall be constructed as detailed on the site plan. Install according to sitework specifications and details.
INFILTRATION BASIN
6.1 Description:
POST-CONSTRUCTION BMPS
6.0
FINAL STABILIZATION
T F A R D
Preparing the soil for vegetative or non-vegetative stabilization; applying mulch or other non-vegetative product to the exposed area; seeding or planting the exposed area; starting any of the activities in listed above on a portion of the area to be stabilized, but not on the entire area; and finalizing arrangements to have stabilization product fully installed in compliance with the applicable deadline for completing stabilization.
For vegetative stabilization, all activities necessary to initially seed or plant the area to be stabilized; and/or For non-vegetative stabilization, the installation or application of all such non-vegetative measures.
7.1
Description:
Final Stabilization
32
Permanent seeding shall be applied immediately after the final design grades are achieved on portions of the site but no later than 7 days after construction activities have permanently ceased. After the entire site is stabilized, any sediment that has accumulated shall be removed and hauled off-site for disposal at an approved landfill. Construction debris, trash and temporary BMPs (including silt fences, material storage areas, sanitary toilets, and inlet protection) shall also be removed and any areas disturbed during removal shall be seeded immediately. Seeding shall be performed in accordance to the Site Plans and Landscape Specifications for the project.
PERMANENT SEEDING
The following sections detail the management practices proposed to achieve final stabilization of the site.
x
x
As soon as practicable, but no later than 7 calendar days after the initiation of soil stabilization measures the following activities are required to be completed:
x
x x x x
In the context of this provision, “immediately” means as soon as practicable, but no later than the end of the next work day, following the day when the earth-disturbing activities have temporarily or permanently ceased. The following activities constitute the initiation of stabilization:
In compliance with the Construction General Permit, soil stabilization measures must be implemented immediately whenever earth-disturbing activities are temporarily or permanently ceased on any portion of the site. Earth-disturbing activities are temporarily ceased when clearing, grading, and excavation within any area of a site that will not include a permanent structure will not resume for a period of 7 or more calendar days, but such activities will resume in the future.
7.0
Maintenance and Inspection:
Installation Schedule:
T F A R D
Final Stabilization
33
Seeding shall occur at portions of the site where construction activities have permanently ceased shall be stabilized, as soon as possible but no later than 14 days after construction ceases. All seeded areas shall be inspected weekly during construction activities for failure and after storm events until a dense cover of vegetation has been established. If failure is noticed at the seeded area, the area shall be reseeded, fertilized, and mulched immediately. After construction is completed at the site, permanently stabilized areas shall be monitored until final stabilization is reached.
INSPECTIONS
8.1
Inspections and Maintenance
For detailed inspection procedures, see Sections 4 and 5.
34
Utility line installation, pipeline construction, and other examples of long, narrow, linear construction activities may limit the access of inspection personnel to the areas described in the above paragraph. Inspection of these areas could require that vehicles compromise temporarily or even permanently stabilized areas, cause additional disturbance of soils, and increase the potential for erosion. In these circumstances, controls shall be inspected on the same frequencies as other construction projects, but representative inspections may be performed. For representative inspections, personnel shall inspect controls along the construction site for 0.25 mile above and below each access point where a roadway, undisturbed right-of-way, or other similar feature intersects the construction site and allows access to the areas described above. The conditions of the controls along each inspected 0.25 mile segment may be considered as representative of the condition of controls along that reach extending from the end of the 0.25 mile segment to either the end of the next 0.25 mile inspected segment, or to the end of the project, whichever occurs first.
T F A R D
Inspections shall include all areas of the site disturbed by construction activity and areas used for storage of materials that are exposed to precipitation. Inspectors shall look for evidence of, or the potential for, pollutants entering the storm water conveyance system. Sedimentation and erosion control measures identified in the SWPPP shall be observed to ensure proper operation. Discharge locations shall be inspected to ascertain whether erosion control measures are effective in preventing significant impacts to waters of the United States, where accessible. Where discharge locations are inaccessible, nearby downstream locations shall be inspected to the extent that such inspections are practicable. Locations where vehicles enter or exit the site shall be inspected for evidence of off-site sediment tracking.
Inspections of the site will be performed once every 7 days and within 24 hours of the end of a storm event of 0.25-inch or greater unless otherwise specified. The inspections will verify that all BMPs required are implemented, maintained, and effectively minimizing erosion and preventing stormwater contamination from construction materials.
8.1.1 Inspection Schedule and Procedures
INSPECTIONS AND MAINTENANCE
8.0
8.3
8.2
T F A R D
See Appendix F – Corrective Action Log.
Inspections and Maintenance
35
If it is determined the stormwater controls have not been installed as required, or that they are not functioning adequately corrective action is required within 7 calendar days.
The corrective action log describes repairs, replacements, and maintenance of BMPs undertaken as a result of the inspections and maintenance procedures. Additionally, remedies of permit violations and clean and proper disposal of spills, releases other deposits should be recorded.
CORRECTIVE ACTION LOG
If earth-disturbing activities are suspended due to frozen conditions inspections can be temporarily suspended until a thaw occurs.
Once an area is stabilized, inspections may be reduced to once per month. If construction resumes at the stabilized area the inspection frequency shall increase as outlined in section 8.1.
REDUCTIONS IN INSPECTION FREQUENCY
For a copy of the inspection report template, see Appendix E.
Inspection reports are required to be completed within 24-hours of an inspection. If corrective actions are identified by the Inspector during the inspection, he/she shall notify and submit a copy of the inspection report to the Operator(s). For corrective actions identified, the project managers shall be responsible for initiating the corrective action within 24 hours of the report and completing maintenance as soon as possible or before the next storm event. For any corrective actions requiring a SWPPP amendment or change to a stormwater conveyance or control design, the project manager shall notify the Owner, as soon as possible, before initiating the corrective action.
All inspections shall be coordinated with a representative from Clean Energy Collective. A Clean Energy Collective representative shall accompany Name of inspector, when possible, during inspections.
9.3
9.2
RECORDKEEPING
9.1
Company/Organization: TBD Name: TBD
9.3.1 Individual(s) Responsible for Training
Record Keeping and Training
36
Prior to the commencement of earth-disturbing activities or pollutant-generating activities, whichever occurs first, training on the pollution prevention measures outlined in this SWPPP shall be provided to staff and subcontractors.
TRAINING
The log of changes to the SWPPP is maintained in Appendix G and includes additions of new BMPs, replacement of failed BMPs, significant changes in the activities or their timing on the project, changes in personnel, changes in inspection and maintenance procedures and update to site plans.
LOG OF CHANGES TO THE SWPPP
Date(s) when an area is either temporarily or permanently stabilized: See Appendix I – Grading and Stabilization Activities Log
Date(s) when construction activities temporarily or permanently cease on a portion of the site: See Appendix I – Grading and Stabilization Activities Log
T F A R D
Date(s) when major grading activities occur: See Appendix I – Grading and Stabilization Activities Log
The following records shall be kept at the project site and shall be available for inspectors to review. These records shall be retained for a minimum period of at least 3 years after the permit is terminated.
A copy of the SWPPP, along with all inspection reports and corrective action logs are required to be stored at an accessible location at the site, and shall be made available upon request of the EPA, or state or local agency approving stormwater management plans.
RECORDKEEPING AND TRAINING
9.0
Record Keeping and Training
T F A R D
37
Formal training shall be provided to all staff and subcontractors with specific stormwater responsibilities, such as installing and maintaining BMPs. The formal training shall cover all design and construction specifications for installing the BMPs and proper procedures for maintaining each BMP. Formal training shall occur before any BMPs are installed on the site. (See Appendix J – Training Log)
Informal training shall be conducted for all staff, including subcontractors, on the site. The training shall be conducted primarily via tailgate sessions and shall focus on avoiding damage to stormwater BMPs and preventing illicit discharges. The tailgate sessions shall be conducted biweekly and shall address the following topics: Erosion Control BMPs, Sediment Control BMPs, Non-Stormwater BMPs, Waste Management and Materials Storage BMPs, and Emergency Procedures specific to the construction site. (See Appendix J – Training Log)
9.3.2 Description of Training Conducted
SIGNATURE, PLAN REVIEW, AND MAKING PLANS AVAILABLE
10.1
T F A R D
NOTICE OF PERMIT COVERAGE
x
x x x
Certification and Notification
38
The NPDES Permit Tracking Number, A contact name and phone number for obtaining additional construction site information, The Uniform Resource Locator (URL) for the SWPPP (if available), or the following statement: “If you would like to obtain a copy of the Stormwater Pollution Prevention Plan (SWPPP) for this site, contact the EPA Regional 1 Office at (617) 918-1038, The following statement “If you observe indicators of stormwater pollutants in the discharge or in the receiving waterbody, contact the EPA through the following website: https://www.epa.gov/enforcement/report-environmental-violations.”
A sign must be posted at a safe, publicly accessible location in close proximity to the construction site detailing the permit coverage. The notice must be located so that it is visible from the public road that is nearest to the active part of the construction site, and it must use a font large enough to be readily viewed from a public right-of-way. At a minimum, the notice must include:
10.2
A copy of the SWPPP (including a copy of the Construction General Permit, NOI, and acknowledgement letter from EPA shall be retained at the construction site (or other location easily accessible during normal business hours to EPA, a state, tribal or local agency approving sediment and erosion plans, grading plans, or storm water management plans; local government officials; the operator of a municipal separate storm sewer receiving discharges from the site; and representatives of the U.S. Fish and Wildlife Service or the National Marine Fisheries Service) from the date of commencement of construction activities to the date of final stabilization. A copy of the SWPPP shall be available at a central location on-site for the use of all those identified as having responsibilities under the SWPPP. If an on-site location is unavailable to store the SWPPP when no personnel are present, notice of the plan’s location shall be posted near the main entrance at the construction site.
CERTIFICATION AND NOTIFICATION
10.0
000000RP000
Project Name Stormwater Pollution Prevention Plan (SWPPP) Town, Massachusetts
10.3
Certification and Notification
T F A R D
Signature:________________________________ Date:_______________________
Name:___________________________________ Title:_______________________
39
I certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gathered and evaluated the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations.
OWNER CERTIFICATION
10.4
Certification and Notification
T F A R D
Signature:________________________________ Date:_______________________
Name:___________________________________ Title:_______________________
40
I certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gathered and evaluated the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations.
OPERATOR CERTIFICATION
T F A R D
APPENDICES
T F A R D General Location Map
Appendix A
T F A R D
Site Plans
Appendix B
Appendix C
https://www.epa.gov/sites/production/files/2017-02/documents/2017_cgp_final_permit_508.pdf
Construction General Permit
T F A R D
Appendix D NOI and Acknowledgement Letter from EPA
T F A R D
Inspection Reports
Appendix E
The following four pages should be copied and completed for each inspection. All inspection forms should be compiled in a binder to prove compliance with this SWPPP.
Inspections under this SWPPP shall be conducted in accordance with each installed BMPs recommended maintenance requirements. This inspection frequency may be reduced to at least once every month if: a) the entire site is temporarily stabilized, b) runoff is unlikely due to winter conditions (e.g. site is covered with snow, ice, or the ground is frozen), or c) construction is occurring during seasonal arid periods in arid areas and semi-arid areas. If an inspection report is filed according to this modified schedule it shall be noted at the end of the report under the “NOTES” section.
T F A R D
Are there any discharges at the time of inspection? Yes If yes, describe:
No
High Winds No
Fog Snowing Temperature: Have any discharges occurred since the last inspection? Yes If yes, describe:
Weather at time of this inspection? Clear Cloudy Rain Sleet Other:
Approx. Amount of Precipitation (in):
During storm event Post-storm event Weather Information Has there been a storm event since the last inspection? Yes No If yes, provide: Storm Start Date & Time: Storm Duration (hrs):
Inspector’s Contact Information Inspector’s Qualifications Describe present phase of construction Type of Inspection: Regular Pre-storm event
Inspector’s Title(s)
T F A R D
Start/End Time
Date of Inspection Inspector’s Name(s)
Location
General Information
NPDES Tracking No.
Project Name
Stormwater Pollution Prevention Plan: Inspection Checklist
E-1
BMP
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Corrective Action Needed and Notes
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
T F A R D
BMP Maintenance Required?
BMP Installed?
E-2
Site-specific BMPs x Number the structural and non-structural BMPs identified in your SWPPP on your site map and list them below (add as many BMPs as necessary). Carry a copy of the numbered site map with you during your inspections. This list will ensure that you are inspecting all required BMPs at your site. x Describe corrective actions initiated, date completed, and note the person that completed the work in the Corrective Action Log.
Are vehicle and equipment fueling, cleaning, and maintenance areas free of spills, leaks, or any other deleterious material?
Are washout facilities (e.g., paint, stucco, concrete) available, clearly marked, and maintained?
Is trash/litter from work areas collected and placed in covered dumpsters?
Is the construction exit preventing sediment from being tracked into the street?
Are storm drain inlets properly protected?
Are discharge points and receiving waters free of any sediment deposits?
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Yes No
Maintenance Required?
E-3
Corrective Action Needed and Notes
T F A R D
Yes No
Are natural resource areas (e.g., streams, wetlands, mature trees, etc.) protected with barriers or similar BMPs?
Yes No
Yes No
Are all slopes and disturbed areas not actively being worked properly stabilized?
Are perimeter controls and sediment barriers adequately installed (keyed into substrate) and maintained?
Implemented?
BMP/activity
Overall Site Issues Below are some general site issues that should be assessed during inspections. Customize this list as needed for conditions at your site.
Yes No
Yes No
Yes No
Yes No
Are non-stormwater discharges (e.g., wash water, dewatering) properly controlled?
(Other)
Corrective Action Needed and Notes
Date:_____________________
Signature:_________________________________________________________
___________________________________________________________________________
Print name and title:
E-4
“I certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gathered and evaluated the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations.”
CERTIFICATION STATEMENT
Describe any incidents of non-compliance not described above:
Non-Compliance
T F A R D
Yes No
Yes No
Are materials that are potential stormwater contaminants stored inside or under cover?
Maintenance Required?
Implemented?
BMP/activity
T F A R D
Corrective Action Log
Appendix F
Date
Additional Action Items
T F A R D
Activity Description
F-1
Use this form to note the date and activity for accurate record keeping (make additional copies as necessary). Examples include the restaking or reinforcement of the erosion control barrier, site watering to prevent dust erosion, street sweeping, equipment and machinery repair, etc.
Corrective Action Log
Appendix G
Based on the results of an inspection, the SWPPP shall be modified as necessary to include additional or modified BMPs designed to correct problems identified. Revisions to the SWPPP shall be completed within seven (7) calendar days following the inspection. Implementation of these additional or modified BMPs shall be accomplished as described in Subpart 3.6B of the Construction General Permit (located in Appendix C).
The SWPPP shall be amended if during inspections or investigations by site staff, or by local, state, tribal or federal officials, it is determined that the SWPPP is ineffective in eliminating or significantly minimizing pollutants in storm water discharges from the construction site.
The SWPPP, including the site plans, shall be amended whenever there is a change in design, construction, operation, or maintenance at the construction site that has or could have a significant effect on the discharge of pollutants to the waters of the United States that has not been previously addressed in the SWPPP.
SWPPP Amendment Log
T F A R D
Amendment No.
Date of Amendment
T F A R D
Description of the Amendment
SWPPP Amendment Log
G-1
Amendment Prepared by (Name(s) and Title)
Appendix H Subcontractor Certifications/Agreements
T F A R D
T F A R D
Date:
Title:
Signature:
Type of construction service to be provided:
Telephone Number:
Address:
Company:
This certification is hereby signed in reference to the above named project:
I certify under the penalty of law that I have read and understand the terms and conditions of the SWPPP for the above designated project and agree to follow the practices described in the SWPPP.
Each subcontractor engaged in activities at the construction site that could impact stormwater must be identified and sign the following certification statement:
As a subcontractor, you are required to comply with the Stormwater Pollution Prevention Plan (SWPPP) for any work that you perform on-site. Any person or group who violates any condition of the SWPPP may be subject to substantial penalties or loss of contract. You are encouraged to advise each of your employees working on this project of the requirements of the SWPPP. A copy of the SWPPP is available for your review at the office trailer.
Operator(s):
Project Title:
Project Number:
SUBCONTRACTOR CERTIFICATION STORMWATER POLLUTION PREVENTION PLAN
Sample Subcontractor Certifications/Agreements
Appendix I
Site Plans in Appendix B should be annotated to indicate areas where final stabilization has been accomplished and no further construction-phase permit requirements apply.
Grading and Stabilization Activities Log
T F A R D
Date
Description
T F A R D
Location on Property
Grading and Stabilization Activities Log
I-1
The following records are to be kept by each Site Operator throughout the construction period and maintained in the SWPPP. Insert additional documentation for record keeping as necessary.
T F A R D
Training Log
Appendix J
Date
Training Log Attendee
T F A R D
Training Topic
Signature of Training Coordinator
J-1
T F A R D
Delegation of Authority
Appendix K
Date:
Signature:
Title:
Company:
Name:
I certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gathered and evaluated the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations.
By signing this authorization, I confirm that I meet the requirements to make such a designation as set forth in Appendix I of EPA’s Construction General Permit (CGP), and that the designee above meets the definition of a “duly authorized representative” as set forth in Appendix I.
T F A R D
________________________________________ (name of person or position) ________________________________________ (company) ________________________________________ (address) ________________________________________ (city, state, zip) ________________________________________ (phone)
I, _______________________ (name), hereby designate the person or specifically described position below to be a duly authorized representative for the purpose of overseeing compliance with environmental requirements, including the Construction General Permit, at the ____________________________________ construction site. The designee is authorized to sign any reports, stormwater pollution prevention plans and all other documents required by the permit.
Delegation of Authority
Sample Delegation of Authority Form
Appendix L Endangered Species Documentation
T F A R D
Appendix M
Historic Preservation Documentation
T F A R D
Appendix N Temporary Sediment Basin Sizing Calculations
T F A R D
Appendix O
Natural Buffer Equivalency Calculations
T F A R D
September 19, 2017 Department of Land Use, Planning & Permitting Hopkinton Planning Board 80 South Main Street Hopkinton, MA 01748 Attn.: Ms. Jennifer Burke, Principal Planner Re:
Hopkinton – 147 Lumber Street – CEC Solar Site Plan Review Peer Review
Dear Ms. Burke: BETA Group, Inc. (BETA) has reviewed the Application for Special Permit, Stormwater Permit and Notice of Intent for the proposed CEC Solar #1206, LLC facility located at 147 Lumber Street in accordance with BETA’s agreement with the Town dated March 31, 2016. This letter is provided to outline BETA’s findings, comments and receomendations. BASIS OF REVIEW The following documents were received by BETA and will form the basis of the review: ·
·
·
·
Application for Special Permit dated August 24, 2017 including the following attachments: o Cover Letters o Project Narrative o Clean Energy Results Document o Abutter Information o Application for Special Permit o Stormwater Management Information Application for Stormwater Management Permit dated August 24, 2017 including the following attachments: o Cover Letter o Abutter Information o Stormwater Management Permit o Exhibits Application o Stormwater Management Report Notice of Intent dated August 24, 2017 including the following attachments: o Cover Letter o Stormwater Management Information o Notice of Intent Forms o Wetland Boundary Documentation o Project Narrative o Plans o Abutter Information Site Plans (19 sheets) entitled “CEC Solar #1206. LLC in Hopkinton, Massachusetts (Middlesex County)” dated August 10, 2017 prepared by Beals and Thomas, Inc., Southborough, MA
Review by BETA will include the above items along with the following: · · · ·
Town of Hopkinton Zoning Bylaws revised through October, 2016 Town of Hopkinton Massachusetts Zoning Map dated May 7, 2012 Water Resource Protection Overlay District (Map) Hopkinton, MA March 2011 Town of Hopkinton Chapter 172 Stormwater Management and Erosion Control Bylaw
BETA GROUP, INC. 315 Norwood Park South, 2nd Floor, Norwood, MA 02062 P: 781.255.1982 | F: 781.255.1974 | W: www.BETA-Inc.com
Department of Land Use, Planning & Permitting September 19, 2017 Page 2 of 6 · ·
Town of Hopkinton Stormwater Management Regulations, amended August 11, 2014 Town of Hopkinton Wetlands Protection Bylaw and Regulations, updated June 16, 2003
INTRODUCTION The project site includes two parcels, 147 Lumbers Street and an adjacent landlocked Parcel 3 to the east totaling 41.5± acres. The project area portions of the parcels are currently wooded. The site is located within the Agriculture (A) Zoning District and portions are within the Water Resources Protection Overlay District (WRPOD-1). The submitted documents indicate that the 2.9 MW (DC) solar array installation will occupy 11.4± acres. The project proposes work within wetland resource areas that requires conforming to the Massachusetts Wetlands Protection Act and Hopkinton Wetlands Protection Bylaw and obtaining an Order of Conditions from the Hopkinton Conservation Commission. The project is proposing stormwater management system expansion which will need to comply with the MassDEP Stormwater Management Standards and the Hopkinton Stormwater Management Bylaw and regulations. GENERAL G1.
Provide details or catalog cuts for equipment to be installed (inverters, switchgear, etc. ).
G2.
Provide AutoTURN plan that indicates access drive and turnaround can accommodate maintenance and emergency vehicles.
ZONING BETA reviewed the Hopkinton Zoning Bylaws in the following applicable sections: Article V Agricultural (A) District The majority of the project is located within the Agricultural District. The parcel is currently nonconforming relative to minimum lot frontage, and the project does not propose a change. Except for frontage, the project meets the minimum dimensional requirements of this section including lot area, lot coverage, setbacks and building coverage. Article XII Water Resources Protection Overlay District (WPROD-1) The project is also located within the Water Resources Protection Overlay District. MassDEP requires that solar arrays be modeled as impervious area, unconnected, therefore the project will exceed the threshold for impervious area. The project however, incorporates required systems of groundwater recharge. Article XVIII Supplementary Regulations (as applicable) The project proposes clearing up to the property line. The proposed nonresidential use does not meet the minimum required buffer zone (75 feet for Agricultural District). The following sections of the Zoning Bylaw are applicable. §210.121.1.A. - A lot which contains a nonresidential use in a Residence A, Residence B, Residence Lake Front or Agricultural District shall contain a buffer area at the perimeter of the lot. The buffer area shall consist of trees, shrubs, vegetation and topographic features sufficient to separate and/or visually screen the use from abutting properties in a residential district and shall be located on the same lot as the nonresidential use.
Department of Land Use, Planning & Permitting September 19, 2017 Page 3 of 6 §210.121.1.B. - The buffer shall be no less than 25 feet wide in a Residence A District; 50 feet wide in a Residence B and Residence Lake Front District; and 75 feet wide in an Agricultural District…. §210.121.1.E. - Upon a finding by the Planning Board that a buffer of lesser width would be sufficient to screen and/or separate the use from adjacent property, the width of the buffer may be reduced. … In those circumstances, it is the intent of the Board not to waive the buffer requirement, but, rather, to provide alternative screening arrangements, such as fencing and planting where possible. Z1.
Revise the design to provide required buffer/screening or provide alternative screening arrangements and request finding from the Planning Board in accordance with §210.121.1.E.
Article XXXI Commercial Solar Photovoltaic Installations Commercial solar photovoltaic installations shall conform to the following provisions: A.
B.
A commercial solar photovoltaic installation may be erected, upon the issuance of a special permit by the Planning Board, on a lot containing a minimum of three (3) acres. Lot contains in excess of 3 acres – conforms. All setback, yard, buffer and screening requirements applicable in the zoning district in which the installation is located shall apply. See Z1 above.
C.
All security fences surrounding the installations shall be set back from the property line a distance equal to the setback requirement applicable to buildings within the zoning district in which the installation is located. Security fencing located outside setback areas – conforms.
D.
The provisions of Article XX, Site Plan Review, shall not apply to commercial solar photovoltaic installations. Site Plan Review not required. The visual impact of the commercial solar photovoltaic installation, including all accessory structures and appurtenances, shall be mitigated. All accessory structures and appurtenances shall be architecturally compatible with each other. Whenever reasonable, structures shall be shielded from view by vegetation and/or joined and clustered to avoid adverse visual impacts. Methods such as the use of landscaping, natural features and fencing may be utilized. See Z1 above.
E.
F.
Lighting shall not be permitted unless required by the Planning Board or by the State Building Code. Where used, lighting shall be directed downward and full cut-off fixtures shall be used. No lighting proposed – conforms.
G.
All utility connections from the commercial solar photovoltaic installation shall be underground unless otherwise specifically permitted otherwise by the Planning Board in the special permit. Electrical transformers and inverters to enable utility interconnections may be above ground if required by the utility provider. Plans indicate underground electric except for the pad mounted switchgear, disconnect and interconnect poles near Lumber Street – conforms.
Approval Criteria: In reviewing any application for a special permit pursuant to this Article, the Planning Board shall give due consideration to promoting the public health, safety, convenience and welfare; shall encourage the most appropriate use of land and shall permit no building or use that is injurious, noxious, offensive or detrimental to its neighborhood. Before the Planning Board may issue such a special permit, it shall determine each of the following: (1)
The commercial solar photovoltaic installation conforms to the provisions of this Article. See above.
Department of Land Use, Planning & Permitting September 19, 2017 Page 4 of 6 (2)
The commercial solar photovoltaic installation will not be detrimental to the neighborhood or the Town. The project will not generate traffic, noise and light impacts. It will not require town services. See Z1
(3)
Environmental features of the site and surrounding areas are protected, and specifically surrounding areas will be protected from the proposed use by provision of adequate surface water drainage. See comments on stormwater management and wetlands below.
(4)
The proposed use is in harmony with the general purpose and intent of this Chapter.
Stormwater Management Permit Review The project is subject to the Stormwater Management Standards (Stormwater Regulations (SWR) 7.0). The following are the 10 standards and relative compliance provided by the submitted documentation. No untreated stormwater (Standard Number 1): No new stormwater conveyances (e.g., outfalls) may discharge untreated stormwater directly to or cause erosion in wetlands or waters of the Commonwealth. The project does not propose untreated stormwater discharges to wetlands. Provided other comments as it relates to stormwater management are addressed – compliance with standard will be achieved. Post-development peak discharge rates (Standard Number 2): Stormwater management systems must be designed so that post-development peak discharge rates do not exceed pre-development peak discharge rates. Calculations provided indicate the project will not increase in peak runoff flows for the 2, 10, 25 and 100 year storm events utilizing rainfall data from the Northeast Regional Climate Center. The model for the proposed condition uses a “meadow, non-grazed” to approximate the surface characteristic when fully constructed. However, once constructed, the surface will not receive rainfall evenly. Some areas under arrays will receive direct rainfall and based on how runoff travels once it falls off the array (sometime under the array and sometime parallel based on the topography) and there will also be some maintenance (mowing) of the grass. SW1.
Based on this BETA recommends revising the calculations using “>75% Grass cover” for CN values under arrays to more closely model expected conditions.
SW2.
Use “water surface” to compute CN values for infiltration basins.
SW3.
P-DA-1B Tc path for developed condition will include flow over grass, revise calculation.
Recharge to groundwater (Standard Number 3): Loss of annual recharge to groundwater should be minimized through the use of infiltration measures to maximum extent practicable. The site is comprised of predominately soils rated in Hydrologic Soil Groups (HSG) A and B in upland areas. The plans indicate that the three infiltration basin areas are to be used as temporary infiltration basins during construction. SW4.
Provide provision to protect infiltrative properties of basins during construction.
SW5.
Provide soil test data within limits of stormwater infiltration basins to identify seasonal high groundwater elevations and to confirm soil classification.
The plans include three infiltration basins but exfiltration is not included in the HydroCAD model. SW6.
Recommend including expected exfiltration based on Rawls rates for the soils confirmed by soil testing to quantify the proposed volume of runoff from the development.
Department of Land Use, Planning & Permitting September 19, 2017 Page 5 of 6 80% TSS Removal (Standard Number 4): For new development, stormwater management systems must be designed to remove 80% of the annual load of Total Suspended Solids. Stormwater runoff from the site discharges to the adjacent wetland areas. The plans include recharge infiltration basins to provide recharge. Higher Potential Pollutant Loads (Standard Number 5): Stormwater discharges from Land Uses with Higher Potential Pollutant Loads require the use of specific stormwater management BMPs. This project documentation does not propose Land Uses with Higher Potential Pollutant Loads – not applicable. Critical Areas (Standard Number 6): Stormwater discharges to critical areas must utilize certain stormwater management BMPs approved for critical areas. A portion of the project area is located with a Zone II Wellhead Protection Area. Project is not likely to generate pollutants that would adversely impact groundwater supplies. It provides treatment of runoff and recharge via infiltration basins – complies with standard. Redevelopment (Standard Number 7): Redevelopment of previously developed sites must meet the Stormwater Management Standards to the maximum extent practicable. This project does not meet the definition of a redevelopment – not applicable. Construction Period Erosion and Sediment Controls (Standard Number 8): Erosion and sediment controls must be implemented to prevent impacts during construction or land disturbance activities. The project site is greater than 1 acre in area and land disturbance activities will require a Notice of Intent with EPA and a Stormwater Pollution Prevention Plan (SWPPP). Site Preparation Plans and a draft Stormwater Pollution Prevention Plan (SWPPP) were provided. SW7.
Include erosion control barriers on sheet C2.2.
SW8.
To reduce potential spread of invasive species, recommend using staked compost filter sock or straw wattle in lieu of staked hay bales.
SW9.
Temporary Sediment Basin Sizing Calculations are not included in Appendix K, provide.
SW10. Recommend that a condition be included that requires submission of copy of NOI submitted to EPA and the final completed and signed SWPPP to Planning Board prior to construction. Operations/Maintenance plan (Standard Number 9): A long-Term Operation and Maintenance Plan shall be developed and implemented to ensure that stormwater management systems function as designed. An Operation and Maintenance Plan was included in the Stormwater Drainage Report. SW11. Provide the names and daytime telephone numbers and signatures of the Responsible Parties SW12. Include map (preferably 11” x 17”) with the Long-Term Operation and Maintenance Plan (LTOMP) to identify and highlight BMP locations to be maintained. SW13. Include provisions for maintaining vegetative cover and the repairing of areas subject to erosion – Appendix C was not included. SW14. Maintenance plan should also include provisions for selective tree maintenance. SW15. Provide provision to notify Planning Board of ownership change. SW16. Add the Planning Board to the list of parties whom are allowed access to inspect stormwater management system and whom the O&M records (2.3) will be made available. Illicit Discharges (Standard Number 10): All illicit discharges to the stormwater management systems are prohibited. An unsigned Illicit Discharge Compliance Statement was included.
Department of Land Use, Planning & Permitting September 19, 2017 Page 6 of 6 SW17. Provide a signed Illicit Discharge Compliance Statement. WETLANDS Portions of the development area are located within the buffer zone of wetland resources and require an Order of Conditions from the Hopkinton Conservation Commission and MassDEP. Limits of work are shown just outside 50 foot buffer zone of bordering vegetated wetlands and 100 feet from potential vernal pool. Parcel 3 slopes down moderately and uniformly to the east wetland resource areas under existing conditions. The proposed plan includes a swale that intercepts runoff at the buffer zone and routes it to the north to an infiltration basin. W1. Consider alternatives to distribute runoff/recharge more uniformly to mimic current conditions and reduce potential impacts to wetland resource areas. If we can be of any further assistance regarding this matter, please contact us at our office. Very truly yours, BETA Group, Inc.
Philip F Paradis, Jr., PE Associate cc:
Don MacAdam
M:\2 Proposals\2017\9058 Hopkinton - 147 Lumber St\147 Lumber St SW Peer Reveiw 9-19-17.docx
TOWN OF HOPKINTON CENTER SCHOOL RE-USE ADVISORY TEAM _____________________________
TOWN HALL 18 MAIN STREET HOPKINTON, MASSACHUSETTS 01748-3209
Dear Department Head or Chair of Board or Committee, With the upcoming opening of the Marathon Elementary School anticipated in the fall of 2018 the Board of Selectmen formed the Center School Re-use Advisory Team to explore the future of Center School. The Board of Selectmen’s charge to the Team is: The Center School Re-Use Advisory Team will recommend, for the Board of Selectmen’s consideration, a plan for the Center School building and property that will provide the Board with valuable outside viewpoints on the use and development of the property. This plan shall outline the community’s vision for the future use of the property and produce recommendations for the Board’s consideration that align with the aspirations of the community.
The Team would appreciate you completing the attached questionnaire to assist us in completing the Team’s mission. If your Department, Board or Committee expresses an interest in using the Center School property, our Team will follow up with you on a more detailed forecast of your needs / requirements and how Center School would need to be retrofitted / adapted to serve your needs. Please try to think long term when considering future needs – the Team is interested in future needs, not just immediate needs. Please complete and return the survey via email to Elaine Lazarus in the Town Manager’s office at [email protected], or on paper, delivered in person to 80 South St. or mailed to 18 Main St., preferably prior to October 1, 2017, and thank you.
Sincerely, Richard A. Flannery, Chair Center School Re-use Advisory Team
Center School Re-use Advisory Team Department and Board / Committee Questionnaire Department, Board or Committee Name: ______________________________________ 1. Is your Department, Board or Committee familiar with the Center School Building and grounds?
2. Does your Department, Board or Committee have any needs that could involve the use of the Center School building and/or grounds? (For example office space, storage space, gymnasium or recreational activities.)
3. Does your Department, Board or Committee have any suggestions or ideas for a Municipal use for the Center School building or grounds?
4. Does your Department, Board or Committee have any suggestions or ideas for a Community use for the Center School building or grounds?
5. Does your Department, Board or Committee have any other suggestions or ideas for a Private use of Center School building or grounds?
6. Does your Department, Board or Committee have any other suggestions or ideas for the use of Center School building or grounds?
7. Does your Department, Board or Committee have any concerns about the use of the Center School building or grounds?
8. Does your Department, Board or Committee have any other suggestion, idea or question regarding the Center School building or grounds that you would like the Team to consider?
HOPKINTON PLANNING BOARD Monday, August 28, 2017 7:30 P.M. HCAM Studio, 77 Main St./Lower Level, Hopkinton, MA
MINUTES MEMBERS PRESENT: John Ferrari, Chairman, Fran DeYoung, Vice Chairman, David Paul, Amy Ritterbusch, Kelly Karp, Frank D’Urso, Cliff Kistner, Irfan Nasrullah, Muriel Kramer Present: Jennifer Burke, Principal Planner; Cobi Wallace, Permitting Assistant Mr. Ferrari opened the meeting, and summarized the Agenda. 1. Continued Public Hearing – 50-60 West Main Street – Site Plan Review – Phase 3 Golden Pond Expansion Project - Golden Pond Resident Care Corporation Kerry Kunst, Golden Pond Resident Care Corporation, applicant, Wayne Davies, attorney, and Joe Marquedant, J.D. Marquedant & Associates, Inc., surveyor, appeared before the Board. Mr. DeYoung, Planning Board project liaison for this application, opened the continued public hearing. Ms. Burke noted the applicant and his engineer met with her, Don MacAdam, Conservation Commission (ConCom) Administrator, and Phil Paradis, BETA Group, Inc., the Board's engineering consultant, on August 2, primarily to discuss drainage and stormwater basin related issues. She stated she believes the meeting was productive although additional information regarding currently still outstanding issues has not yet been submitted. Mr. Davies stated Mr. Marquedant has talked with BETA and progress has been made, with a few things still to be resolved. He referred to Ms. Burke's summary on page 2 of her memorandum to the Board. He noted during Phase 2 of the Golden Pond expansion project, the Fire Dept. had requested that access between the two buildings be preserved but is now reconsidering that requirement. He noted Golden Pond is currently working on plan modifications, including revised landscape and lighting plans, to reflect the Fire Dept.'s change in approach. Mr. DeYoung noted Mr. Paradis previously had identified a number of issues, and it appears the consultants are working together, therefore perhaps their comments can be consolidated. Mr. D’Urso asked for clarification regarding the status of the stormwater basin issue, and Mr. Davies stated the ConCom has concurrent jurisdiction here but there is no agreement yet. Mr. Marquedant stated they have looked at past data and reached out to the engineer who did the site work for Phase 2 to determine why the basin is not functioning correctly, and hopefully they will be able to come up with a solution. Mr. DeYoung asked if the work on Phase 3 will take care of the issue automatically, and Mr. Davies stated they plan to resolve the outstanding issues with the ConCom. Mr. Paradis stated he has been to the site a couple of times observing conditions firsthand, however, the cause of the problem is a bit of a mystery. He noted as discussed on August 2 there is a lot of available data but more research is needed and he has not heard back from the applicant. Mr. DeYoung suggested the applicant continue working with BETA, and Mr. Marquedant noted he anticipates making progress on the issue.
1
The Board discussed Item 7, Traffic, on the public hearing outline prepared for this proposal. Mr. Marquedant stated a traffic study was submitted and reviewed in 2012, and Ron Müller of Ron Müller & Associates, was asked to look at the impact of Phase 3. He quoted from the summary on page 2 of Mr. Müller's report dated May 2, 2017, and stated traffic impact of this phase will be negligible, maintaining safe traffic flow and pedestrian/vehicle access conditions once construction is done. Mr. Paradis noted BETA agrees with Mr. Müller's conclusions. The Board moved on to the next item on the outline, Building Design. Ms. Burke noted the applicant met with the Design Review Board (DRB), but the members had no specific comments and/or recommendations and there were no changes to the plans as a result of the meeting. Ms. Kramer arrived at this time. Mr. D'Urso asked about the lack of street views, and Mr. Davies noted the building is in the back and the illustrations included in the application are clear in that respect. Mr. D’Urso noted the building can be seen from Elm St. He noted Golden Pond did a good job in Phase 2 and he is not too concerned but thought BETA had asked about it. Ms. Ritterbusch stated the DRB had no concerns and it appears the addition will be tucked in there, but privacy of Phase 2 vs. Phase 3 residents may be an issue. Mr. Davies questioned how that would fall within the DRB jurisdiction and assured the Board it will not be a problem. The Board referred to the Stormwater item on the public hearing outline, and Mr. Davies stated he feels the issue should be continued to the next meeting. Mr. DeYoung asked about the parking lot design, and Mr. Davies noted there will be no significant changes to the lot. Reference was made to snow removal provisions, and Mr. Marquedant noted the current plan sets aside a couple of spaces for temporary snow storage and it has worked out ok since 2012. Mr. Nasrullah asked if Phase 3 will require additional parking spaces, and Mr. Marquedant stated the number of spaces constructed in 2013 satisfies the requirement for the entire expansion project and they have what they need. Mr. Davies stated the facility actually has 14 more spaces than needed under the bylaw. Mr. DeYoung asked about parking spaces for cars belonging to permanent Golden Pond residents, and Mr. Davies noted this is an assisted living facility and a significant number of people don't drive at all. Mr. D’Urso referred to a BETA comment regarding light spillage onto adjacent property, and Mr. DeYoung noted it will be addressed as part of the BETA issues still outstanding. Mr. Davies reminded the Board they are currently still relying on Phase 2 landscaping and lighting plans which will be supplemented for Phase 3 now that the Fire Chief has been a little more flexible with respect to access requirements. Stephen Slaman, Fire Chief, noted the Fire Dept. reviewed the plans a few weeks ago, and is now considering changing its approach with respect to access between the Phase 2 and Phase 3 buildings additional analysis. Mr. Paul asked about landscaping/screening concerns, and Mr. Davies noted they have not been able to provide a new plan but are not aware of any concerns. Mr. DeYoung asked about Utilities, and Mr. Marquedant stated a new water loop and a municipal sewer connection through the emergency access on Elm St. were handled in 2012, and no additional changes are anticipated at this time. Reference was made to BETA's most recent comment letter, and Mr. Marquedant noted it may be necessary to move the sewer force main if during construction is it found to be too close to the footing system for the Phase 3 addition. Ms. Burke asked if the applicant has received an answer from John Westerling, Director of Public Works, with respect to the request for an increase of sanitary flow from the facility, and Mr. 2
Marquedant noted the request was discussed with the Water/Sewer Superintendent but he is still waiting to hear from Mr. Westerling. In response to comments from Board members, Mr. Marquedant indicated he will follow up with Mr. Westerling on behalf of the applicant on a few issues related to this project. Mr. Kistner referred to the BETA comment regarding a retaining wall south of the new building, and Mr. Marquedant noted this issue is part of the access area mentioned by the Fire Chief and may be resolved by a revised design. It was determined to leave the Utilities item open pending the response from the DPW Director. Mr. Paul asked if the applicant would be willing to add curbing along West Main St. as part of this project, and Mr. Kunst stated yes, to the extent that it is similar to what was done further down the street. Mr. Paul noted it would make it look a little nicer and keep sand/salt off the grass. Mr. Marquedant referred to the proposed Construction Management Plan and noted the focus is on the southerly side of the site to address concerns regarding delivery vehicles access and parking for subcontractors during construction. He described the proposed traffic pattern and noted the applicant also controls the property at 62 West Main St. for temporary storage and additional parking. He noted it is felt the proposed arrangement will make sure Golden Pond residents can still use the northerly part of the site for walking and exercise. Ms. Ritterbusch asked about access for emergency vehicles during construction, and Chief Slaman noted he is not sure whether there is a plan yet, noting it was difficult during the first phases as well as the most recent small addition, and perhaps they will need the Police Dept. to monitor the site especially as the facility continues to expand. Ms. Burke asked where the construction workers are going to park, and Mr. Marquedant noted throughout the site and in dedicated spots. Mr. Davies noted a lot of these issues will be under the supervision of the Building Inspector, but if necessary, Golden Pond will find more offsite parking to address any concerns. Mr. Paul read through the draft conditions of approval listed in Ms. Burke's memo to the Board, and stated that 4 out of 7 are construction related. Mr. D'Urso noted these are just draft conditions and the Board may make changes and/or add to them. The Board closed out the Construction Management Plan item, and noted that as far as comments/input from other Boards or Committees are concerned, the project was ok'd by the DRB while an agreement on conservation issues is still outstanding. Ms. Burke noted the ConCom continued its hearing on this proposal to September 18. Mr. Davies summarized the outstanding issues. Ms. Kramer moved to continue the public hearing to September 25, 2017 at 7:30 P.M., Mr. D'Urso seconded the motion, and the Board voted unanimously in favor. 2. Legacy Farms North Villages - Pulte Homes - Request for Signage off Premises Reid Blute, Pulte Homes, proponent, appeared before the Board. Mr. Blute stated Pulte Homes has been in Hopkinton for a number of years developing residential portions of the overall Legacy Farms project, is about to finish the Legacy Farms South and currently in the beginning phases of the Legacy Farms North villages. He noted Pulte Homes up to now had a temporary sales sign for the Legacy Farms South development on the south side of East Main St. near the intersection with Legacy Farms South, and would like to install a similar sign to advertise for the new homes in Legacy Farms North, thinking that simply switching it to the other side of the street would make the most sense. He noted it is important for people to be able to easily locate the new homes which are quite a distance from East Main St., and a sign on the main road would 3
address that need and minimize confusion. He noted they have submitted an application to install the sign, and feel the proposed location is a good spot, considering the south and north developments are essentially part of one overall project in the OSMUD (Open Space Mixed Use Development) zoning district. Ms. Burke noted the OSMUD district has its own design guidelines and sign stipulations requiring real estate signs to be on the premises, and placement across the street would clearly be offsite. She added the Planning Board has the ability to waive the requirement under the bylaw. It was noted there currently is a small "New Homes" sign about 150 ft. in from East Main St., and Mr. Blute stated that if the Town allows his request, those would no longer be needed. Ms. Ritterbusch asked if the sign is proposed to be installed on the property with the historical home, and Mr. Blute stated yes, on the corner at the intersection with Legacy Farms North. Mr. Blute used a map of Legacy Farms to explain the location of the new homes, noting that signage as proposed would avoid confusion. Ms. Ritterbusch stated she understands the desire to avoid confusion, but does not like this type of signage near a historic home. Mr. D'Urso stated the two Pulte development parcels are not contiguous and he is not in favor of granting a waiver, and in this day and age prospective customers should not have any problems finding the new homes. Mr. Blute noted Pulte Homes noted they could uncover and keep the current sign, and Ms. Burke noted it would still need Planning Board permission. Mr. Paul noted moving the sign across the street would a "net zero" in his opinion and it would be better than having signs stapled to telephone poles. Mr. Ferrari asked how long the requirement has been in effect, and Ms. Burke stated for 7 years. Mr. Ferrari stated the Town has lived with this requirement all this time, and he is not looking to go back questioning the decision of a previous board to put the restriction in place. He noted if the Board grants a waiver, assuming Legacy Farms North will be under construction for another 6 or 7 years, the Town essentially will end up having a temporary sales sign for up to 14 years. The Board continued the discussion of Mr. Blute's request and the implications of granting a waiver. Ms. Burke noted that the previous board would not have included a waiver provision if it did not anticipate a need for it at some point during the life of the overall OSMUD development. Mr. D'Urso stated no one has mentioned input from Frankland Road residents on this issue, and based on that he supports the regulation as it stands. He moved to deny the request. Mr. Ferrari stated part of the issue is the size of the Legacy Farms North street sign which is not easy to spot, and perhaps a more visible sign would allow easier identification of the new homes while also indicating the location of the new bypass road. Mr. Blute stated Pulte Homes was not involved with the design and installation of the street sign, and Mr. Paul stated he is not in favor of a different style for the Legacy Farms neighborhoods. Ms. Burke stated Legacy Farms is not yet an accepted road and the Board is getting off topic. Mr. Nasrullah seconded the motion. Ms. Ritterbusch stated off premises real estate signs are not allowed in other parts of Town and granting the request would set a precedent. Robert Falcione, editor, HopNews, provided his opinion as a downtown business owner, and noted signage on East Main St. would be helpful from a business perspective and encourage people to use the Legacy Farms North shortcut. Chief Slaman stated Mr. Ferrari's idea of a larger Legacy Farms North street sign would be 4
interesting and beneficial from his perspective. Mr. DeYoung stated he agrees with Mr. Falcione that the temporary real estate sign would reduce confusion, stay true to the OSMUD design ideas, and it will not be a blight. Ms. Kramer noted she likes the idea of attractive identifying signs for the Legacy Farms developments eventually, also from a public safety perspective, but she cannot imagine the risk of confusion is that great and she does not a see a reason to change the bylaw to accommodate a private business. Ms. Karp stated she is willing to grant the waiver and review any future such requests on a case-by-case basis. Ms. Burke noted this concerns a regulation, not a bylaw. Mr. Nasrullah noted he agrees with Ms. Kramer and waiving the requirement may set a precedent. 3. Public Hearing - Minor Project Site Plan Review - 52 Wilson St. - A/Z Corporation Ms. Kramer moved to open and continue the public hearing upon the conclusion of the request of Pulte Homes for an off premise real estate sign for the Legacy Farms North villages, the motion was seconded and the Board voted unanimously in favor. 4. Legacy Farms North Villages - Pulte Homes - Request for Signage off Premises Continued Discussion Mr. Blute offered to work with someone on making the Legacy Farms North street sign more visible. Mr. Paul stated the Town in general has decided to make new development inclusive and is not in favor of variations on permanent street signs. The Board voted to deny Pulte Home's request 5 in favor (Kramer, Ritterbusch, Ferrari, Nasrullah, D'Urso) and 4 opposed (Paul, DeYoung, Karp, Kistner). Mr. Blute thanked the Board for its time. The Board took a 5 minute break. Ms. Kramer suggested making decisions on applications by making motions in the affirmative, making the outcome easier to understand. 5. Continued Public Hearing - Minor Project Site Plan Review - 52 Wilson St. - A/Z Corporation Ms. Kramer moved to reopen the public hearing, Mr. Ferrari seconded the motion, and the Board voted unanimously in favor. Glenn Stewart and Richard Drake, A/Z Corporation, applicant, and James Blackburn, Project Manager, Eversource Energy, appeared before the Board. Ms. Burke noted this is a minor site plan application for construction of a warehouse/machine shop accessory building at 52 Wilson St. She noted the application was submitted in May of this year but the public hearing process was delayed pending the outcome of a legal opinion by Town Counsel as to compliance with the zoning bylaw. She noted there were some discussions between Eversource and Town Counsel, and in July the decision was made in July that construction of the proposed building is allowed as an accessory use under site plan review. Mr. Blackburn provided background information on the facility which has been there for 47 years, and noted they propose to construct a new structure on site to increase and improve storage space for equipment and consumables in a more secure, temperature controlled indoor space. 5
Mr. Drake explained the proposal in more detail, noting it concerns the construction of a preengineered structure less than 5,000 s.f. in size, in compliance with the minimum setback requirements under the zoning bylaw in an area of the site that is currently empty. He described the floor plan which was revised from the original submission as a result of the Board of Health's requirements for hand wash and bathroom facilities. In response to a question of Mr. Kistner, Mr. Blackburn indicated the type of materials that will be stored in the new building, noting that currently some of these items are kept in boxes. Mr. DeYoung asked if the new building will be visible from the street or the Legacy Farms North development, and Mr. Blackburn stated people will not be able to see it from Wilson St. and he does not think it will be noticeable from the Legacy Farms walking trails. In response to a question of Mr. Paul regarding utilities, it was noted that everything is above ground with cable trays throughout the facility. The applicant described the building design in detail, including elevations and exterior finish. The Board discussed lighting, and Mr. Drake noted there will be wall packs above the door openings, with more conventional fixtures on the inside, all LID. Mr. Ferrari asked if there will be changes to landscaping or screening, and Mr. Blackburn stated they do not intend to change anything. Mr. Paul asked for clarification regarding the initial zoning concerns, and Ms. Burke explained that the use is not allowed in the Agricultural district, but that the facility is operating under an exemption issued by the Dept. of Public Utilities. She noted it was not clear at first if construction of this particular building was included in the existing DPU zoning exemption, but Town Counsel determined that there was no reason to go back to the DPU. In response to a question of Mr. D'Urso, Mr. Blackburn stated this particular proposal is not at all related to anything else Eversource is doing in Town, and is strictly a standalone project. Mr. D'Urso asked if it is still possible to locate the gas metering station planned for Elm St. at the Wilson St. campus instead, and Mr. Blackburn stated he personally believes it will not work from a spacing standpoint. In response to a question of Mr. Paul, Mr. Blackburn noted Air Products has operated the facility for 47 years and is currently contracted by Eversource who has owned it for the last 43 years. Mr. Ferrari asked about the process for approval, and Ms. Burke stated it is the same as for other site plan applications. Reference was made to Ms. Burke's memo to the Board, and the Board reviewed the draft conditions with the applicant. At the request of Ms. Karp, the applicant clarified existing utilities and noted that the application was accurate when originally filed but needed to be modified due to the Board of Health requirements. Mr. D'Urso suggested an additional condition requiring signoff from the Board of Health, and Ms. Burke stated the building permit process already addresses that requirement. Mr. D'Urso moved to find that the proposal concerns a minor site plan application, the application complies with the standards of site plan approval under the bylaw, and to approve the site plan with the following conditions: 1. The applicant shall be responsible for mitigating all construction related impacts, including erosion, siltation and dust control in a timely manner. (Site Plan Standard G) 2. The applicant shall regularly remove construction trash and debris from the site in accordance with good construction practice. No tree stumps, demolition material, trash or debris shall be burned or buried on the site. (Site Plan Standard G)
6
3. Mechanical equipment or other utility hardware on the roof, grounds or buildings shall be screened from view from the ground. (Site Plan Standard Q) 4. The Director of Municipal Inspections inspects Site Plans under construction for compliance with the approved Decision of Site Plan Review. If the Director of Municipal Inspections determines at any time before or during construction that a registered professional engineer or other such outside professional is required to assist with the inspections of the storm water management system or any other component of the Site Plan, the Applicant shall be responsible for the cost of those inspections. (All Site Plan Standards & § 210-137) 5. In accordance with § 210-138 of the Zoning Bylaw, the Applicant shall provide a performance guarantee in the amount of $3,000 to the Town prior to the commencement of construction pursuant to this Decision. The guarantee shall consist of a deposit of money or negotiable securities in a form selected by the Planning Board to guarantee that any unforeseen problems which arise, such as erosion and sedimentation and the correction of site lighting problems, are addressed. The funds will be held by the Town and returned to the Applicant upon completion of the project. (All Site Plan Standards & § 210-137) 6. Construction may occur only between the hours of 7:00 AM and 7:00 PM Monday through Friday and Saturdays between 8:00 AM and 4:00 PM pursuant to Chapter 141 Article 1 of the Town of Hopkinton General Bylaws. Mr. Paul seconded the motion and the Board voted unanimously in favor. Ms. Kramer moved to close the public hearing, Ms. Karp seconded the motion, and the Board voted unanimously in favor. 6. Box Mill Road (off Leonard St. Subdivision) - Rick Barbieri - Set Performance Guarantee Rick Barbieri, developer, appeared before the Board. Ms. Burke stated Mr. Barbieri submitted an estimate of remaining work, and the Board's inspecting engineer came back with a revised estimate in the amount of $97,560.00, which includes a 20% contingency. She noted the Board typically adds another $5,000.00 for legal fees for street acceptance resulting in a total amount of $102,560.00. Mr. Barbieri stated the amount is acceptable. Ms. Burke stated this particular development is somewhat unique as it concerns a subdivision through the approval-not-required (ANR) plan process, not involving lot releases from a conditional approval agreement, but requiring a performance guarantee to be established prior to the issuance of building permits. Mr. D'Urso asked about the number of homes to be built, and Mr. Barbieri stated there will be 3 in total and he plans to start as soon as the bond is posted. He noted the sewer stubs are in and the wells are installed. In response to a question of Mr. D'Urso, Mr. Barbieri stated he decided on private wells because the Town just replaced a 2 in. pipe with another 2 in. pipe which is inadequate. Mr. Kistner moved to establish a performance guarantee for Box Mill Road in the amount of $102,560.00, Ms. Kramer seconded the motion, and the Board voted unanimously in favor. Mr. Barbieri requested to discuss another issue related to Box Mill Road, and it was determined only the performance guarantee discussion was scheduled on tonight's agenda. The Board suggested that Mr. Barbieri follow up with Ms. Burke in the office. Mr. Kistner stepped off the Board at this time. 7. Saddle Hill Road - Scenic Road Violation - Saddle Hill Realty LLC - Discussion 7
John Parsons, and Victor Galvani, Saddle Hill Realty LLC, and David Anderson, Parsons Commercial Group, Project Manager, appeared before the Board. Ms. Burke noted a week and half ago she was informed by Bryan Besso, Board of Health Agent, about the removal of a section of stone wall and trees for site work at the Saddle Hill Road property owned by Saddle Hill Realty LLC. She noted she subsequently received an email from Mr. D'Urso with the same information, after which she contacted Mr. Galvani, issued an immediate Cease & Desist, and agreed to meet the developers on site the next day. She stated she met with Mr. Galvani and others on site the next day, looked at the area in question, measured the opening in the wall, and asked Mr. Galvani to appear before the Board tonight to discuss the violation. She stated it appeared that 23 ft. of stone wall was removed, resulting in a maximum fine of 23 x $300.00/linear foot for a total of $6,900.00. She stated they then walked along Saddle Hill Road and determined there was an existing opening further south with only low ground cover but no stones, and gave the developers permission to access the site there to continue the work as long as they restored the other opening to its original condition by noon the next day. She noted on the following Monday she met Mr. D'Urso on site after he informed her of another violation, which is the subject of some disagreement. Mr. Ferrari noted he walked the site more than a year ago when the property was evaluated for potential purchase as open space. but at this point there is a clear violation, amounting to 23 ft. of stone wall disturbance. He noted the Board will discuss the issue tonight, and perhaps a site walk will be helpful to take a look at conditions firsthand. Mr. D'Urso noted he feels there are 2 areas that were violated, with a third open to discussion based on input from neighbors who contacted him as well as one abutter who contacted Ms. Burke directly. He noted he does not understand how the work was allowed to start, without any notification of abutters, followed almost immediately with a scenic road violation and damage to the road. He noted people are concerned about the process and he asked for clarification as to what is expected as part of the ANR approval process. Ms. Burke noted abutter notification is not required under an ANR plan, and the lots in question have frontage on Saddle Hill Road. She noted the owners are therefore allowed to do site work and cut trees on their own property without prior approval as long as they are outside the wetlands buffer zone. Mr. D'Urso noted he feels the developers should not have been allowed to continue working for 8 days once the scenic road violation was identified. He stated he was also told that a tractor trailer brought onto the site would be removed, and that did not happen. Mr. Anderson referred to the section of stone wall removed without prior permission, and noted he believed it would be ok as long as they kept the stones for reuse. He noted he has done a lot of work in Hopkinton but has never been before the Board and apparently did not talk to the right people and ask the right questions. He noted when informed of the violation they immediately stopped the work and the wall was restored before noon the next day. He stated they clearly did the wrong thing, but truly value the scenic road character and take full responsibility. Ms. Kramer asked if any trees were cut as part of the violation, and Ms. Burke noted her inspection did not show any evidence of that. It was noted the work was prompted by the need for site testing, and Mr. Galvani stated they had all intentions to do this the right way and he was very disappointed to see the extent of the break in the wall. Ms. Karp asked if there any photos of the area from before this event, and Mr. Ferrari suggested using Google Earth. He suggested setting 8
up a site visit and continue the discussion at the next meeting. Mr. Nasrullah noted from his perspective this concerns an open violation and there is a process to be followed where the appropriate parties have a chance to take a look before anything else happens. Ms. Karp noted she is not questioning Ms. Burke's decision but feels the Board should have the opportunity to do some additional investigation before making further determinations. Josh Deisenroth, 74 Saddle Hill Rd. noted there are definitely 3 violations, 2 near Palomino Dr., already identified, the 3rd opening approved for access by the Principal Planner, and other locations where on numerous occasions the rocks were removed temporarily and put back later. Ms. Burke stated she disagrees and believes that is not what happened. Mr. D'Urso stated he disagrees on the process followed and does not understand how the developer is allowed to continue work with an additional violation without having to answer for the initial ones. He noted he feels Ms. Burke as an individual or employee of the Town did not have the authority to allow access through the opening further down. He noted only the Board as a whole has the authority to allow or disallow further work upon further investigation. Mr. Paul asked about the plan going forward, and Ms. Burke noted the developer has already submitted scenic road applications for 4 driveway openings. Mr. Paul stated he does not see a reason for asking the developer to stop work based on the available information. Ms. Karp noted it seems clear there was a violation, but she is not sure the applicants are continuing to violate. Mr. D'Urso noted only the Planning Board can make that decision. Ms. Kramer stated Saddle Hill Road residents have observed stones being moved, which would be a problem, and Mr. Anderson stated he is not aware of that happening. Mr. D'Urso noted the developers promised that the tractor trailer would be removed, and he has a photo of the northernmost stone wall section which shows that 14.9 ft. and 23 ft. sections were removed in that location. Ms. Burke noted she would like the record to show that she was never told the tractor trailer would be removed. Mr. D'Urso moved to require the proponents to stop all work until further investigation of the areas in question, Ms. Kramer seconded the motion. Mr. D'Urso noted he has pictures and a video to help make his point. Mr. Paul noted the developer will need approval for a total of 11 breaks in the wall, and asked about a complete plan. Mr. Parsons stated they need additional testing and the engineering has not been completed yet. Mr. Paul stated he feels the developers are going about this the wrong way, and asked about their decision to withdraw the subdivision plan, and Mr. Parsons noted it would have been very expensive and too time-consuming from a marketing perspective. Mr. Parson asked the Board to let them continue cutting trees as the issue is access to the property. The Board voted unanimously in favor of the motion. Mr. Kistner returned to the Board at this time. The Board scheduled a site walk for Saddle Hill Road on Saturday, September 9, 2017, at 9:00 A.M. to view the area of the scenic road violation discussed tonight. ADJOURNED: 10:15 P.M. Submitted by: Cobi Wallace, Permitting Assistant Approved ________________ Documents used at the Meeting:
9
Agenda for August 28, 2017 Planning Board meeting Memorandum from Jennifer Burke, Principal Planner, to Planning Board, dated August 23, 2017 re: Items on August 28, 2017 Planning Board Agenda Public Hearing Outline – Site Plan Review – 50-60 West Main St. – Golden Pond Expansion Project, Phase 3; Plans entitled “The Lofts at Golden Pond”, dated May 15, 2017 revised through July 17, 2017, prepared by J.D. Marquedant & Assoc., Inc.; letter to Town of Hopkinton Planning Board, Attn: Ms. Jennifer Burke, Principal Planner, from Philip F. Paradis, Jr. and Christopher Luppino, dated July 24, 2017, re: Site Plan Review Update for The Golden Pond Residential Care Corporation – Hopkinton, MA Public Hearing Outline – Site Plan Review – 52 Wilson Street; Letter to Jennifer Burke, Principal Planner from J. Raymond Miyares, Miyares and Harrington LLP, dated July 21, 2017 re: HOPCO Warehouse; Application for Site Plan Review, 52 Wilson St., Glenn Stewart, A/Z Corporation, for Air Products Warehouse Bldg; Memorandum from Bryan Besso, BOH Health Agent, to Cobi Wallace, Permitting Assistant, DLUPP, dated August 8, 2017, re: 52 Wilson St./Hopkinton LNG Corporation - Air Products Warehouse Maintenance Building - Minor Site Plan Review; Plans entitled Air Products Warehouse Building 52 Wilson Street, Hopkinton, Massachusetts, prepared by Loureiro Engineering, dated May 8 th, 2017, revised through August 28, 2017 Box Mill Road (off Leonard Street Subdivision) – Proposed Performance Guarantee, marked up by Bayassociates, Inc., dated 08/17/17 Legacy Farms North – Proposed “New Homes” Sign, & Locus Plan - Pulte Homes Draft Minutes – August 14, 2017 Missed Meeting Certificate – Frank D’Urso (July 24, 2017/Golden Pond Phase 3)
10