W

ith ONE PLUS RTU M1212-DNC you

have a powerful RTU and Data Logging system available with compatible price today. The flexible data logging feature with reliable multiple I/O makes ONE PLUS RTU M1212DNC is one of the finest RTU and Data Logging system that suites for wide range of industrial application. ONE PLUS RTU M1212DNC is designed for specific field works area such Oil/Gas Industry, Water and Waste Water management-Distribution, Electricity Power Management /Distribution including Electricity Load Research or Traffic Management and Control Application. ONE PLUS RTU M1212-DNC is capturing up to 500 Hz of frequency input (At Single Mode). The system measures the frequency of dual pulse inputs and counts them at the same time, so you will have Counting Cumulative and Frequency in Hz information ready for logging. The dual pulses can be configured as Flow Direction + and -, so the reverse direction is automatically compensate to the total flow. And with the high resolution 12bit Analog Input for 8 Channels plus up to 5 Points by software calibration curve that available for each Analog Input channel make ONE PLUS RTU M1212DNC the most powerful data logging and RTU device. ONE PLUS RTU M1212-DNC is built-in with 3G Industrial Modem. All Logging data can be sent to host server automatically. The internet connection can be automatically recovered when network is failed or unreachable.

The Log data Setup, Communication Setting and System parameters can be easily configured using our LogMaster interface software via Ethernet port. So ONE PLUS RTU M1212-DNC is a great idea for global data logging solutions. Key Features: • Flexible Data Collection and Transmission • Data Logger with Large and expandable memory Transmission Mode • Calling Mode (Self Reporting Mode) In this mode data can be transmitted to Server as follows: - Data is transmitted by Event Conditions (I/O trigger Conditions) or/and - Data is transmitted by time period routine • Listening Mode (Interrogation Mode) • Modem Conversation dialog allows you to online diagnostic the AT base command communication Between RTU and MODEM. This make easy for user to diagnostic the communication problem • Real Time Remote Terminal application allow user to monitor all of the input/output online values. This is convenience when diagnostic the analog and digital input including RS232 • SMS or call number Alarm by DI and AI Input Condition selectable by user (up to 15 Numbers) • Interface to WEB Server for Data Report and WEB Report using FTP or HTTP protocol • Integrated with Software and Hardware Watchdog With automatically reset on halt feature

Specification:

M1212-DNC

Digital Input /Output

: 16 Channels (Assignable for DI and DO from the total of 16 Channels) Pulse Input : 2 Channels (MODE1: Single Pulse Input) (MODE2: Dual Pulse Input) (MODE3: Pulse Direction +/-) Analog Input : 12Bit x 8Channels Analog output 12Bit x 2Channels RS232 : 2 Channels (Channel 1: MODBUS RTU) (Channel 2: ONLINE DIAG.) RS485 : 1 Channels (Smart Meter) Ethernet : 1 Channel (MODUS TCP/IP or Configuration) SIM Card : 1.8/3.0 V Calibration : Up to 5 Points Calibration curve is available for each Analog Input channel independently. Real Time Clock on Board Memory

: 256 MB Flash Memory (1 second. interval for at least 1 year at 5 input parameters)

Expanded

: 4GB Flash Memory (Optional)

Software and Hardware Watchdog Enclosure : IP68 Protection Power Supply : 9-32 VDC (Max. 212mA @12VDC) Operating Temperature : -30 to +60 C

M1212-DNC

G P R S / 3G

LogMaster

(1) Calling Mode (Self Reporting Mode) transmits Data to Server (Up to 5 FTP and HTTP Servers)

Real Time Remote Terminal application allow user to monitor all of the input/output online values. This is convenience when diagnostic the analog and digital input including RS232 port data (MODBUS)

(2) Listening Mode (Interrogation Mode) (FTP Server or MODBUS Slave) Modem Conversation dialog allows you to online diagnostic the AT base command communication between RTU and MODEM. This make easy for user to diagnostic the communication problem

Digital Input/Output General Purpose 16 Digital Channels which can be configured as the digital input or output channel. This general purpose I/O can be utilized for HOV Loop Control, P&ID and etc.

SMS or call Number Alarm by DI/AI Each DI and AI Channel can trigger the SMS Alarm or call to destination number when it meets with the condition specified by user. 15 SMS Numbers and 15 Destination calling Numbers can be programmed and map on each DI and AI individually

High Resolution Analog Inputs With a high resolution 12 bit x 8 A/I Channels and 12 bit x 2 A/O Channels including 5 Points by software calibration curve that available for each Analog Input

0-20 mA 4-20 mA

2 Communication Modes

0-5VDC 1-5VDC

Dual Pulse Inputs Capture up to 500 Hz of frequency input (At Single Mode). The system measures the frequency of dual pulse inputs and counts them at the same time, so you will have both Counting Cumulative and Frequency in Hz information ready for logging. The dual input pulses can be configure as Flow Direction + and -, so the reverse direction is automatically compensate to the total flow

Logging Feature All Input Parameters are logged with software selectable period from 1 sec to 86,400 sec (1 day). All Log data can be loaded to PC via LogMaster. Logging type including - Snap short log and Averaging log (Time Weight Formulaic) on Analog Input Signal and Frequency Input. - Snap short on Cumulative Pulse Counting Input. - Snap short on Current Logging Period Pulse Counting Input. - Averaging Flow Rate Calculation base on Gross Input Count / Specified Time Period (Count/Time) with software configurable. - Snap short log on Digital Input Signal. - Events Alarm logging from DI/AI conditioning or SMS Alarm or destination calling logging.

M1212-DNC

100%

System Configurable via

LogMaster

Software. License is free for every unit of ONE PLUS RTU SERIES

Data Transmission Feature There are 2 Data Transmission modes available: Calling Mode (Self Reporting Mode) - Automatic FTP Data Transmission. ONE PLUS RTU M1212DNC sends the log data to specified FTP host with authorized user privilege with user configurable period starting from 1 minute period to 30 days period. The numbers of log to be transmitted each time are also user selectable. Listening Mode (Interrogation Mode) - Wait for incoming command and send back the request log item information back to host. This mode is available on both GSM and GPRS connections WCDMA 900 / 2100 MHz, Quad Band GSM 850 / 900 / 1800 / 1900 MHz/GPRS Class 12 at maximum speed, FULL TCP/IP Stack, FTP, TCP/IP Support

Industrial Technology Supply Co., Ltd. 49/438 M4 Ekachai Road, Muang Samutsakhon 74000, Thailand Tel: +66 3483 4840-2 http://www.plc-scada.net Fax: +66 3486 3500 [email protected]

M1212-DNC

SAMPLE OF ALARM MESSAGE AND CALLING APPLICATION

G P R S / 3G SMS or call Number Alarm by DI/AI Each DI and AI Channel can trigger the SMS Alarm or call to destination number when it meets with the condition specified by user. 15 SMS Numbers and 15 Destination calling Numbers can be programmed and map on each DI and AI individually SMS Alarm is powerful since User can define Alarm channel name to each of analog or Digital input. When the physical inputs hit the Condition settle by User, alarm will be sent to Each SMS alarm individually with the full Message name, also it comes with alarm type (Low/High) alarm for each analog input. All Alarms when they are reset, User also have an option neither to send or not to send the alarm reset message via SMS to the user.

Alarm Logging Feature Alarm Logging can be sent via GPRS Network All Logging files are saved into FTP and HTTP protocol format which can be easily viewed via Web application (up to 5 servers can be added)

8 A/I - Configurable Analog Inputs Condition for Alarm Trigger. All Analog Input channel 1-4 support 4-20 mA Current Input. For Analog input channel 4-8 support voltage measurement with Software voltage range selectable 0–20 V, 0–10 V, 0–5 V, 0–4 V, 0–2.5 V 0–2 V, 0–1.25 V, 0–1 V (DC) 16 D/I - Configurable Line Digital Inputs for Alarm Trigger. The actual switching threshold is approximately 1.40 V. Anything below this value is a logic 0, and anything above 1.90 V is a logic 1. The configurable I/O are each fully protected over a range of 0 V to +36 V, and can handle short spikes from -5 V to +40 V.

M1212-DNC

SAMPLE OF ONE PLUS RTU APPLICATION

M1212-DNC

SAMPLE OF ONE PLUS RTU APPLICATION

M1212-DNC

SAMPLE OF ONE PLUS RTU APPLICATION

M1212-DNC

SAMPLE OF ONE PLUS RTU APPLICATION

M1212-DNC

SAMPLE OF ONE PLUS RTU APPLICATION

M1212-DNC

SAMPLE OF ALARM SMS APPLICATION

M1212-DNC

SAMPLE OF ALARM CALLING APPLICATION

M1212-DNC

SAMPLE OF ONE PLUS RTU APPLICATION

M1212-DNC

SAMPLE OF ONE PLUS RTU APPLICATION

Spec ONE PLUS .pdf

There was a problem previewing this document. Retrying... Download. Connect more apps... Try one of the apps below to open or edit this item. Spec ONE ...

1MB Sizes 3 Downloads 119 Views

Recommend Documents

Group 284 Spec. 260 Spec. 288 Spec. 237 Spec. 265 ...
0-Chan Dimr. Use. Group. Position #. Special. Color. 1. 284. 1. Spec. 2Bm 19. 6x16 ... 36° Source Four R02. 34. 403. K. Front. 1Bm 12. 36° Source Four R08 ...

Undertale Spec Script.pdf
Whoops! There was a problem loading more pages. Retrying... Undertale Spec Script.pdf. Undertale Spec Script.pdf. Open. Extract. Open with. Sign In. Details.

CS4 Spec Sheet.pdf
Advanced design. software allows ... Designed and Optimized for Post 2009 Digital TV Frequencies. The ClearStreamTM 4 ... CS4 Spec Sheet.pdf. CS4 Spec ...