Asbestos and Hazardous/Regulated Material Survey Report For the Vacant Residential Property Located at:
5969 Newport Detroit, Michigan P.O. #: 1.27.2016D Project # ABF-16-1799 Date: March 7, 2016 Prepared by:
Prepared for:
ABF Environmental 28200 Orchard Lake Road, Suite 101 Farmington Hills, Michigan, 48334 Phone: 586-405-5416
James Wright Detroit Building Authority 1301 Third Street, Suite 328 Detroit, MI 48226
Jennifer Parker
___________________________________ Jennifer Parker State Certified Inspector #A32713
Table of Contents 1.0
INTRODUCTION ................................................................................................................................. 1
2.0
SUMMARY OF FINDINGS ................................................................................................................... 1
3.0
RECOMMENDATIONS........................................................................................................................ 2
4.0
LIMITATIONS ..................................................................................................................................... 4
TABLE 1 (ASBESTOS-CONTAINING MATERIALS) ............................................................................................ 1 TABLE 2 (HAZARDOUS/ REGULATED MATERIALS) ........................................................................................ 2
APPENDICES APPENDIX A - INSPECTOR ACCREDITATION APPENDIX B - LABORATORY ANALYTICAL RESULTS AND CHAIN OF CUSTODY FORMS APPENDIX C - EXHIBITS D, E, H, I, AND SITE DIAGRAM(S)
APPENDIX D - SITE PHOTOGRAPHS
1.0
INTRODUCTION
On February 15, 2016, State of Michigan Asbestos Inspector, Jennifer Parker (A32713), conducted a pre-demolition asbestos and hazardous/regulated material survey of the unoccupied residential property located at 5969 Newport in Detroit, Michigan. The dwelling is a two-story home with a basement and a garage. Debris was present throughout the dwelling. A copy of the inspector’s proof of accreditation with the State of Michigan is provided in Appendix A. The purpose of this survey was to task an accredited asbestos inspector to complete a predemolition asbestos and hazardous/regulated material survey of the site and provide recommendation options for removal and disposal prior to demolition of the building. All areas were accessible. 2.0
SUMMARY OF FINDINGS
The following Tables listed below provide a summary of findings for the pre-demolition asbestos and other regulated materials survey. Table 1 identifies the asbestos-containing materials (>1% asbestos) identified during the survey, their locations, approximate quantity, type and percentage of asbestos. TABLE 1 (ASBESTOS-CONTAINING MATERIALS) ID#
Material
Location
Approximate Quantity
Result
10 A-C
Floor Tile
Basement, Rear Porch
500 SF
Tile – 5 % Chrysotile
The suspect ACM that was sampled and found to not contain more than one percent asbestos is presented on Exhibit E in Appendix B. A copy of required forms Exhibit D, E, H, and I, including a site diagram is provided in Appendix C. Samples were analyzed by a NVLAP certified laboratory (certificate attached) by polarized light microscopy (PLM) using first positive stop. Sampling methodology and QA/QC are indicated on the attached laboratory results. No other suspect ACM was observed on the Site. Although not anticipated based on surface observations, underground structures that could contain ACM may be present and should be managed accordingly if encountered prior to our during demolition. Abatement of ACMs, including non-friable ACMs, must be performed by a State of Michigan licensed, certified and registered asbestos abatement contractor in accordance with state and federal Occupational Safety and Health Administration (OSHA) and local air quality management regulations. Sampling procedures were performed in accordance with Asbestos Hazard Emergency Response Act, 40 CFR Part 763 (AHERA) protocols by State of Michigan licensed asbestos inspectors. Elements of the asbestos building inspections were based on practices specified in the National Page 1
Emission Standards for Hazardous Air Pollutants (NESHAPS), Michigan Public Act 440 of 1988, U.S. Environmental Protection Agency (EPA) and Occupational Safety and Health Administration (OSHA) standards and included the identification of homogeneous areas within the subject facilities, bulk sample collection of suspect materials, and laboratory analysis. Field activities were performed by Accredited Asbestos Building Inspectors as recognized by the State of Michigan Department Labor and Economic Growth (MDLEG) who have met the requirements of Section 206 of the Toxic Substances Control Act and the Asbestos School Hazard Abatement Reauthorization Act (ASHARA). Sample locations were selected to be representative of homogeneous materials identified within the buildings. Samples were obtained in a manner to minimize damage and, where possible, were collected from previously exposed/damaged locations. Factors used in the selection of sample locations included accessibility, potential for occupant exposure, and/or general safety. Photographs of each side of the building followed by photographs of sample location areas are provided in Appendix D. Lead-based paint may be present on the site and is a hazardous substance. Its condition, handling and disposal are regulated by federal, state, and local agencies. LBP generally does not pose a health threat unless particles are disturbed, become airborne and are inhaled or ingested. Contractors and their employers that will be disturbing the building during demolition should follow all applicable requirements in the OSHA Lead in Construction Standard. Further testing may be required of debris generated from demolition activities to determine whether the debris should be disposed as hazardous waste under the Resource Conservation and Recovery Act (RCRA) in accordance with 40-CFR Part 261 Subpart C. We also performed an Hazardous/ Regulated Materials (ORM) assessment of the site structure to identify potential areas/ items of environmental concern in/on the structures that require decontamination or disposal prior to demolition. The Other Regulated Materials identified within the structure are identified in the following table, including locations and quantities. TABLE 2 (HAZARDOUS/ REGULATED MATERIALS) Floor
IOI Description
Location
1
Thermostats
B
Tires
3.0
Size
Comments
Disposal Concern
Quantity
Units
Dining Room
1
Each
Disposal
Basement
1
Each
Tire Disposal
RECOMMENDATIONS
Except for the following items listed below, Section 61.145(c) of the Asbestos NESHAP requires that each owner or operator of a demolition or renovation activity involving RACM remove all such material from a facility being demolished or renovated before any activity begins that would break up, dislodge, or similarly disturb the material or preclude access to the material for
Page 2
subsequent removal. Contractors performing asbestos abatement should notify the State of Michigan in accordance with NESHAP, 40 CFR Part 61, Subpart M and State requirements. ACM need not be removed before demolition if it: (i) Is a Category I non-friable ACM that is not friable. (ii) Is on a facility component that is encased in concrete or other similarly hard material and is adequately wet whenever exposed during demolition. (iii) Was not accessible for testing and therefore was not discovered until after demolition began and, as a result of the demolition, cannot be safely removed. If not removed for safety reasons, the exposed RACM and any asbestos-contaminated debris must be treated as asbestoscontaining waste material and kept adequately wet at all times until disposed of. (iv) Is a Category II non-friable ACM and the probability is low that the material will become crumbled, pulverized, or reduced to powder during demolition. Demolition with Roofing Materials in Place is covered under the NESHAP regulations (40 CFR Part 61 Subpart M). Roofing materials (if found to be asbestos containing) is considered a Category I asbestoscontaining material. Since demolition activities do not include sanding, grinding, cutting, or abrading, Category I asbestos-containing roofing materials not in poor condition and not friable are not considered RACM and are allowed to remain in place during demolition. If the asbestos-containing roofing material is not in poor condition and is not friable, it may be disposed of in a landfill which accepts ordinary demolition waste. The asbestos-containing roofing material may not be ground up for recycling into other products. In addition, contractors should ensure they follow all OSHA regulations pertaining to demolition of Category I Asbestos-containing materials. Category I or II non-friable ACM that is not subject to 61.150(a)(3) would still have to be disposed of in a landfill that accepts building debris, in a landfill that operates in accordance with 61.154, or at a facility that operates in accordance with 61.155. Prior to demolition, the following is recommended: A licensed asbestos abatement company in the State of Michigan should remove the materials identified in Table 1 in accordance with all applicable Local, State, and Federal Requirements prior to demolition. Removal, transportation, disposal and / or recycling activities for the ORMs should be performed by a licensed contractor with training and experience in handling the items identified, in accordance with all applicable regulations.
Page 3
4.0
LIMITATIONS
The results, findings, conclusions, and recommendations expressed in the report are based only on conditions that were noted during the assessment of the vacant above-referenced residential property. Any conditions or materials that could not be visually identified through limited destructive sampling were not inspected and may differ from those conditions or materials noted. The user of this report should keep in mind that conditions at the time of the site reconnaissance may not be consistent with future observations made by others. If during demolition, asbestos containing materials are identified or if suspect asbestoscontaining materials that were not previously identified and/or samples are encountered, work should stop, access to the suspect material should be restricted, and sampling should be performed by a State of Michigan licensed asbestos inspector. Any positive ACMs must be abated by a licensed asbestos abatement contractor. The report is designed to aid the building owner, architect, construction manager, general contractors, and potential asbestos abatement contractors in locating asbestos building materials to be removed prior to demolition activities. This report is not intended to be utilized as a bidding document or as a project specification document. Contractors bidding the demolition of this site should field verify project information.
Page 4
APPENDIX A INSPECTOR ACCREDITATION
APPENDIX B LABORATORY ANALYTICAL RESULTS AND CHAIN OF CUSTODY FORMS
Certificate of Laboratory Analysis Test Method, Polarized Light Microscopy (PLM) Project: 5969 Newport Project # ABF-16-1799
Report To: Mr. Bill O'brien/ Fred Abdou ABF Environmental 28200 Orchard Lake Rd., Ste. 101 Farmington Hills, MI 48334
Sample Information
ARI Report # Date Collected: Date Received: Date Analyzed: Date Reported:
Asbestos Type/Percent
16-63045 02/15/16 02/17/16 02/22/16 02/22/16
Non-Asbestos
Lab ID #: 63045 - 01 Cust. #: 1A Material: Plaster - Finish Coat Location: Appearance: white,nonfibrous,homogenous Layer: 1 of 3
Asbestos Present: NO No Asbestos Observed
Other - 100%
Lab ID #: 63045 - 01a Cust. #: 1A Material: Base Coat Location: Appearance: grey,fibrous,homogenous Layer: 2 of 3
Asbestos Present: NO No Asbestos Observed
Cellulose - 2% Other - 98%
Lab ID #: 63045 - 01b Cust. #: 1A Material: Drywall Location: Appearance: grey,fibrous,homogenous Layer: 3 of 3
Asbestos Present: NO No Asbestos Observed
Cellulose - 20% Other - 80%
For Layered Samples, each component will be analyzed and reported separately.
Robert T. Letarte Jr., Laboratory Director Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.
NVLAP Lab Code 102118-0
APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991
Page 1 of 23
Certificate of Laboratory Analysis Test Method, Polarized Light Microscopy (PLM) Project: 5969 Newport Project # ABF-16-1799
Report To: Mr. Bill O'brien/ Fred Abdou ABF Environmental 28200 Orchard Lake Rd., Ste. 101 Farmington Hills, MI 48334
Sample Information
ARI Report # Date Collected: Date Received: Date Analyzed: Date Reported:
Asbestos Type/Percent
16-63045 02/15/16 02/17/16 02/22/16 02/22/16
Non-Asbestos
Lab ID #: 63045 - 02 Cust. #: 1B Material: Plaster - Finish Coat Location: Appearance: white,nonfibrous,homogenous Layer: 1 of 3
Asbestos Present: NO No Asbestos Observed
Other - 100%
Lab ID #: 63045 - 02a Cust. #: 1B Material: Base Coat Location: Appearance: grey,fibrous,homogenous Layer: 2 of 3
Asbestos Present: NO No Asbestos Observed
Cellulose - 2% Other - 98%
Lab ID #: 63045 - 02b Cust. #: 1B Material: Drywall Location: Appearance: grey,fibrous,homogenous Layer: 3 of 3
Asbestos Present: NO No Asbestos Observed
Cellulose - 20% Other - 80%
For Layered Samples, each component will be analyzed and reported separately.
Robert T. Letarte Jr., Laboratory Director Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.
NVLAP Lab Code 102118-0
APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991
Page 2 of 23
Certificate of Laboratory Analysis Test Method, Polarized Light Microscopy (PLM) Project: 5969 Newport Project # ABF-16-1799
Report To: Mr. Bill O'brien/ Fred Abdou ABF Environmental 28200 Orchard Lake Rd., Ste. 101 Farmington Hills, MI 48334
Sample Information
ARI Report # Date Collected: Date Received: Date Analyzed: Date Reported:
Asbestos Type/Percent
16-63045 02/15/16 02/17/16 02/22/16 02/22/16
Non-Asbestos
Lab ID #: 63045 - 03 Cust. #: 1C Material: Plaster - Finish Coat Location: Appearance: white,nonfibrous,homogenous Layer: 1 of 3
Asbestos Present: NO No Asbestos Observed
Other - 100%
Lab ID #: 63045 - 03a Cust. #: 1C Material: Base Coat Location: Appearance: grey,fibrous,homogenous Layer: 2 of 3
Asbestos Present: NO No Asbestos Observed
Cellulose - 2% Other - 98%
Lab ID #: 63045 - 03b Cust. #: 1C Material: Drywall Location: Appearance: grey,fibrous,homogenous Layer: 3 of 3
Asbestos Present: NO No Asbestos Observed
Cellulose - 20% Other - 80%
For Layered Samples, each component will be analyzed and reported separately.
Robert T. Letarte Jr., Laboratory Director Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.
NVLAP Lab Code 102118-0
APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991
Page 3 of 23
Certificate of Laboratory Analysis Test Method, Polarized Light Microscopy (PLM) Project: 5969 Newport Project # ABF-16-1799
Report To: Mr. Bill O'brien/ Fred Abdou ABF Environmental 28200 Orchard Lake Rd., Ste. 101 Farmington Hills, MI 48334
Sample Information
ARI Report # Date Collected: Date Received: Date Analyzed: Date Reported:
Asbestos Type/Percent
16-63045 02/15/16 02/17/16 02/22/16 02/22/16
Non-Asbestos
Lab ID #: 63045 - 04 Cust. #: 1D Material: Plaster - Finish Coat Location: Appearance: white,nonfibrous,homogenous Layer: 1 of 3
Asbestos Present: NO No Asbestos Observed
Other - 100%
Lab ID #: 63045 - 04a Cust. #: 1D Material: Base Coat Location: Appearance: grey,fibrous,homogenous Layer: 2 of 3
Asbestos Present: NO No Asbestos Observed
Cellulose - 2% Other - 98%
Lab ID #: 63045 - 04b Cust. #: 1D Material: Drywall Location: Appearance: grey,fibrous,homogenous Layer: 3 of 3
Asbestos Present: NO No Asbestos Observed
Cellulose - 20% Other - 80%
For Layered Samples, each component will be analyzed and reported separately.
Robert T. Letarte Jr., Laboratory Director Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.
NVLAP Lab Code 102118-0
APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991
Page 4 of 23
Certificate of Laboratory Analysis Test Method, Polarized Light Microscopy (PLM) Project: 5969 Newport Project # ABF-16-1799
Report To: Mr. Bill O'brien/ Fred Abdou ABF Environmental 28200 Orchard Lake Rd., Ste. 101 Farmington Hills, MI 48334
Sample Information
ARI Report # Date Collected: Date Received: Date Analyzed: Date Reported:
Asbestos Type/Percent
16-63045 02/15/16 02/17/16 02/22/16 02/22/16
Non-Asbestos
Lab ID #: 63045 - 05 Cust. #: 1E Material: Plaster - Finish Coat Location: Appearance: white,nonfibrous,homogenous Layer: 1 of 3
Asbestos Present: NO No Asbestos Observed
Other - 100%
Lab ID #: 63045 - 05a Cust. #: 1E Material: Base Coat Location: Appearance: grey,fibrous,homogenous Layer: 2 of 3
Asbestos Present: NO No Asbestos Observed
Cellulose - 2% Other - 98%
Lab ID #: 63045 - 05b Cust. #: 1E Material: Drywall Location: Appearance: grey,fibrous,homogenous Layer: 3 of 3
Asbestos Present: NO No Asbestos Observed
Cellulose - 20% Other - 80%
For Layered Samples, each component will be analyzed and reported separately.
Robert T. Letarte Jr., Laboratory Director Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.
NVLAP Lab Code 102118-0
APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991
Page 5 of 23
Certificate of Laboratory Analysis Test Method, Polarized Light Microscopy (PLM) Project: 5969 Newport Project # ABF-16-1799
Report To: Mr. Bill O'brien/ Fred Abdou ABF Environmental 28200 Orchard Lake Rd., Ste. 101 Farmington Hills, MI 48334
Sample Information
ARI Report # Date Collected: Date Received: Date Analyzed: Date Reported:
Asbestos Type/Percent
16-63045 02/15/16 02/17/16 02/22/16 02/22/16
Non-Asbestos
Lab ID #: 63045 - 06 Cust. #: 1F Material: Plaster - Finish Coat Location: Appearance: white,nonfibrous,homogenous Layer: 1 of 3
Asbestos Present: NO No Asbestos Observed
Other - 100%
Lab ID #: 63045 - 06a Cust. #: 1F Material: Base Coat Location: Appearance: grey,fibrous,homogenous Layer: 2 of 3
Asbestos Present: NO No Asbestos Observed
Cellulose - 2% Other - 98%
Lab ID #: 63045 - 06b Cust. #: 1F Material: Drywall Location: Appearance: grey,fibrous,homogenous Layer: 3 of 3
Asbestos Present: NO No Asbestos Observed
Cellulose - 20% Other - 80%
For Layered Samples, each component will be analyzed and reported separately.
Robert T. Letarte Jr., Laboratory Director Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.
NVLAP Lab Code 102118-0
APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991
Page 6 of 23
Certificate of Laboratory Analysis Test Method, Polarized Light Microscopy (PLM) Project: 5969 Newport Project # ABF-16-1799
Report To: Mr. Bill O'brien/ Fred Abdou ABF Environmental 28200 Orchard Lake Rd., Ste. 101 Farmington Hills, MI 48334
Sample Information
ARI Report # Date Collected: Date Received: Date Analyzed: Date Reported:
Asbestos Type/Percent
16-63045 02/15/16 02/17/16 02/22/16 02/22/16
Non-Asbestos
Lab ID #: 63045 - 07 Cust. #: 1G Material: Plaster - Finish Coat Location: Appearance: white,nonfibrous,homogenous Layer: 1 of 3
Asbestos Present: NO No Asbestos Observed
Other - 100%
Lab ID #: 63045 - 07a Cust. #: 1G Material: Base Coat Location: Appearance: grey,fibrous,homogenous Layer: 2 of 3
Asbestos Present: NO No Asbestos Observed
Cellulose - 2% Other - 98%
Lab ID #: 63045 - 07b Cust. #: 1G Material: Drywall Location: Appearance: grey,fibrous,homogenous Layer: 3 of 3
Asbestos Present: NO No Asbestos Observed
Cellulose - 20% Other - 80%
For Layered Samples, each component will be analyzed and reported separately.
Robert T. Letarte Jr., Laboratory Director Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.
NVLAP Lab Code 102118-0
APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991
Page 7 of 23
Certificate of Laboratory Analysis Test Method, Polarized Light Microscopy (PLM) Project: 5969 Newport Project # ABF-16-1799
Report To: Mr. Bill O'brien/ Fred Abdou ABF Environmental 28200 Orchard Lake Rd., Ste. 101 Farmington Hills, MI 48334
Sample Information
ARI Report # Date Collected: Date Received: Date Analyzed: Date Reported:
Asbestos Type/Percent
16-63045 02/15/16 02/17/16 02/22/16 02/22/16
Non-Asbestos
Lab ID #: 63045 - 08 Cust. #: 2A Material: Insulation Location: Appearance: grey,fibrous,homogenous Layer: 1 of 1
Asbestos Present: NO No Asbestos Observed
Mineral Wool - 90% Other - 10%
Lab ID #: 63045 - 09 Cust. #: 2B Material: Insulation Location: Appearance: grey,fibrous,homogenous Layer: 1 of 1
Asbestos Present: NO No Asbestos Observed
Mineral Wool - 90% Other - 10%
Lab ID #: 63045 - 10 Cust. #: 2C Material: Insulation Location: Appearance: grey,fibrous,homogenous Layer: 1 of 1
Asbestos Present: NO No Asbestos Observed
Mineral Wool - 90% Other - 10%
For Layered Samples, each component will be analyzed and reported separately.
Robert T. Letarte Jr., Laboratory Director Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.
NVLAP Lab Code 102118-0
APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991
Page 8 of 23
Certificate of Laboratory Analysis Test Method, Polarized Light Microscopy (PLM) Project: 5969 Newport Project # ABF-16-1799
Report To: Mr. Bill O'brien/ Fred Abdou ABF Environmental 28200 Orchard Lake Rd., Ste. 101 Farmington Hills, MI 48334
Sample Information
ARI Report # Date Collected: Date Received: Date Analyzed: Date Reported:
Asbestos Type/Percent
16-63045 02/15/16 02/17/16 02/22/16 02/22/16
Non-Asbestos
Lab ID #: 63045 - 11 Cust. #: 3A Material: Floor Tile Location: Appearance: grey,fibrous,homogenous Layer: 1 of 1
Asbestos Present: NO No Asbestos Observed
Cellulose - 2% Other - 98%
Lab ID #: 63045 - 12 Cust. #: 3B Material: Floor Tile Location: Appearance: grey,fibrous,homogenous Layer: 1 of 1
Asbestos Present: NO No Asbestos Observed
Cellulose - 2% Other - 98%
Lab ID #: 63045 - 13 Cust. #: 3C Material: Floor Tile Location: Appearance: beige,nonfibrous,homogenous Layer: 1 of 1
Asbestos Present: NO No Asbestos Observed
Other - 100%
For Layered Samples, each component will be analyzed and reported separately.
Robert T. Letarte Jr., Laboratory Director Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.
NVLAP Lab Code 102118-0
APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991
Page 9 of 23
Certificate of Laboratory Analysis Test Method, Polarized Light Microscopy (PLM) Project: 5969 Newport Project # ABF-16-1799
Report To: Mr. Bill O'brien/ Fred Abdou ABF Environmental 28200 Orchard Lake Rd., Ste. 101 Farmington Hills, MI 48334
Sample Information
ARI Report # Date Collected: Date Received: Date Analyzed: Date Reported:
Asbestos Type/Percent
16-63045 02/15/16 02/17/16 02/22/16 02/22/16
Non-Asbestos
Lab ID #: 63045 - 14 Cust. #: 4A Material: Floor Tile Location: Appearance: beige,fibrous,homogenous Layer: 1 of 1
Asbestos Present: NO No Asbestos Observed
Cellulose - 2% Other - 98%
Lab ID #: 63045 - 15 Cust. #: 4B Material: Floor Tile Location: Appearance: grey,nonfibrous,homogenous Layer: 1 of 1
Asbestos Present: NO No Asbestos Observed
Other - 100%
Lab ID #: 63045 - 16 Cust. #: 4C Material: Floor Tile Location: Appearance: grey,nonfibrous,homogenous Layer: 1 of 1
Asbestos Present: NO No Asbestos Observed
Other - 100%
For Layered Samples, each component will be analyzed and reported separately.
Robert T. Letarte Jr., Laboratory Director Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.
NVLAP Lab Code 102118-0
APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991
Page 10 of 23
Certificate of Laboratory Analysis Test Method, Polarized Light Microscopy (PLM) Project: 5969 Newport Project # ABF-16-1799
Report To: Mr. Bill O'brien/ Fred Abdou ABF Environmental 28200 Orchard Lake Rd., Ste. 101 Farmington Hills, MI 48334
Sample Information
ARI Report # Date Collected: Date Received: Date Analyzed: Date Reported:
Asbestos Type/Percent
16-63045 02/15/16 02/17/16 02/22/16 02/22/16
Non-Asbestos
Lab ID #: 63045 - 17 Cust. #: 5A Material: Ceramic Tile Location: Appearance: white,nonfibrous,homogenous Layer: 1 of 2
Asbestos Present: NO No Asbestos Observed
Other - 100%
Lab ID #: 63045 - 17a Cust. #: 5A Material: Mortar Location: Appearance: grey,nonfibrous,homogenous Layer: 2 of 2
Asbestos Present: NO No Asbestos Observed
Other - 100%
Lab ID #: 63045 - 18 Cust. #: 5B Material: Ceramic Tile Location: Appearance: white,nonfibrous,homogenous Layer: 1 of 2
Asbestos Present: NO No Asbestos Observed
Other - 100%
For Layered Samples, each component will be analyzed and reported separately.
Robert T. Letarte Jr., Laboratory Director Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.
NVLAP Lab Code 102118-0
APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991
Page 11 of 23
Certificate of Laboratory Analysis Test Method, Polarized Light Microscopy (PLM) Project: 5969 Newport Project # ABF-16-1799
Report To: Mr. Bill O'brien/ Fred Abdou ABF Environmental 28200 Orchard Lake Rd., Ste. 101 Farmington Hills, MI 48334
Sample Information
ARI Report # Date Collected: Date Received: Date Analyzed: Date Reported:
Asbestos Type/Percent
16-63045 02/15/16 02/17/16 02/22/16 02/22/16
Non-Asbestos
Lab ID #: 63045 - 18a Cust. #: 5B Material: Mortar Location: Appearance: grey,nonfibrous,homogenous Layer: 2 of 2
Asbestos Present: NO No Asbestos Observed
Other - 100%
Lab ID #: 63045 - 19 Cust. #: 5C Material: Ceramic Tile Mortar Location: Appearance: grey,nonfibrous,homogenous Layer: 1 of 1
Asbestos Present: NO No Asbestos Observed
Other - 100%
Lab ID #: 63045 - 20 Cust. #: 6A Material: Ceramic Tile Mortar Location: Appearance: grey,nonfibrous,homogenous Layer: 1 of 1
Asbestos Present: NO No Asbestos Observed
Other - 100%
For Layered Samples, each component will be analyzed and reported separately.
Robert T. Letarte Jr., Laboratory Director Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.
NVLAP Lab Code 102118-0
APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991
Page 12 of 23
Certificate of Laboratory Analysis Test Method, Polarized Light Microscopy (PLM) Project: 5969 Newport Project # ABF-16-1799
Report To: Mr. Bill O'brien/ Fred Abdou ABF Environmental 28200 Orchard Lake Rd., Ste. 101 Farmington Hills, MI 48334
Sample Information
ARI Report # Date Collected: Date Received: Date Analyzed: Date Reported:
Asbestos Type/Percent
16-63045 02/15/16 02/17/16 02/22/16 02/22/16
Non-Asbestos
Lab ID #: 63045 - 21 Cust. #: 6B Material: Ceramic Tile Mortar Location: Appearance: white,nonfibrous,homogenous Layer: 1 of 1
Asbestos Present: NO No Asbestos Observed
Other - 100%
Lab ID #: 63045 - 22 Cust. #: 6C Material: Ceramic Tile Mortar Location: Appearance: white,nonfibrous,homogenous Layer: 1 of 1
Asbestos Present: NO No Asbestos Observed
Other - 100%
Lab ID #: 63045 - 23 Cust. #: 7A Material: Brick Mortar Location: Appearance: brown,nonfibrous,homogenous Layer: 1 of 1
Asbestos Present: NO No Asbestos Observed
Other - 100%
For Layered Samples, each component will be analyzed and reported separately.
Robert T. Letarte Jr., Laboratory Director Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.
NVLAP Lab Code 102118-0
APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991
Page 13 of 23
Certificate of Laboratory Analysis Test Method, Polarized Light Microscopy (PLM) Project: 5969 Newport Project # ABF-16-1799
Report To: Mr. Bill O'brien/ Fred Abdou ABF Environmental 28200 Orchard Lake Rd., Ste. 101 Farmington Hills, MI 48334
Sample Information
ARI Report # Date Collected: Date Received: Date Analyzed: Date Reported:
Asbestos Type/Percent
16-63045 02/15/16 02/17/16 02/22/16 02/22/16
Non-Asbestos
Lab ID #: 63045 - 24 Cust. #: 7B Material: Brick Mortar Location: Appearance: grey,nonfibrous,homogenous Layer: 1 of 1
Asbestos Present: NO No Asbestos Observed
Other - 100%
Lab ID #: 63045 - 25 Cust. #: 7C Material: Brick Mortar Location: Appearance: brown,nonfibrous,homogenous Layer: 1 of 1
Asbestos Present: NO No Asbestos Observed
Other - 100%
Lab ID #: 63045 - 26 Cust. #: 8A Material: Wallboard Adhesive Location: Appearance: grey,nonfibrous,homogenous Layer: 1 of 1
Asbestos Present: NO No Asbestos Observed
Other - 100%
For Layered Samples, each component will be analyzed and reported separately.
Robert T. Letarte Jr., Laboratory Director Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.
NVLAP Lab Code 102118-0
APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991
Page 14 of 23
Certificate of Laboratory Analysis Test Method, Polarized Light Microscopy (PLM) Project: 5969 Newport Project # ABF-16-1799
Report To: Mr. Bill O'brien/ Fred Abdou ABF Environmental 28200 Orchard Lake Rd., Ste. 101 Farmington Hills, MI 48334
Sample Information
ARI Report # Date Collected: Date Received: Date Analyzed: Date Reported:
Asbestos Type/Percent
16-63045 02/15/16 02/17/16 02/22/16 02/22/16
Non-Asbestos
Lab ID #: 63045 - 27 Cust. #: 8B Material: Wallboard Adhesive Location: Appearance: grey,nonfibrous,homogenous Layer: 1 of 1
Asbestos Present: NO No Asbestos Observed
Other - 100%
Lab ID #: 63045 - 28 Cust. #: 8C Material: Wallboard Adhesive Location: Appearance: white,nonfibrous,homogenous Layer: 1 of 1
Asbestos Present: NO No Asbestos Observed
Other - 100%
Lab ID #: 63045 - 29 Cust. #: 9A Material: Window Glaze Location: Appearance: beige,nonfibrous,homogenous Layer: 1 of 1
Asbestos Present: NO No Asbestos Observed
Other - 100%
For Layered Samples, each component will be analyzed and reported separately.
Robert T. Letarte Jr., Laboratory Director Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.
NVLAP Lab Code 102118-0
APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991
Page 15 of 23
Certificate of Laboratory Analysis Test Method, Polarized Light Microscopy (PLM) Project: 5969 Newport Project # ABF-16-1799
Report To: Mr. Bill O'brien/ Fred Abdou ABF Environmental 28200 Orchard Lake Rd., Ste. 101 Farmington Hills, MI 48334
Sample Information
ARI Report # Date Collected: Date Received: Date Analyzed: Date Reported:
Asbestos Type/Percent
Non-Asbestos
Lab ID #: 63045 - 30 Cust. #: 9B Material: Window Glaze Location: Appearance: beige,nonfibrous,homogenous Layer: 1 of 1
Asbestos Present: NO No Asbestos Observed
Other - 100%
Lab ID #: 63045 - 31 Cust. #: 9C Material: Window Glaze Location: Appearance: beige,nonfibrous,homogenous Layer: 1 of 1
Asbestos Present: NO No Asbestos Observed
Other - 100%
Lab ID #: 63045 - 32 Cust. #: 10A Material: Floor Tile Location: Appearance: brown,fibrous,homogenous Layer: 1 of 2
Asbestos Present: Chrysotile - 5%
YES
16-63045 02/15/16 02/17/16 02/22/16 02/22/16
Other - 95%
For Layered Samples, each component will be analyzed and reported separately.
Robert T. Letarte Jr., Laboratory Director Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.
NVLAP Lab Code 102118-0
APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991
Page 16 of 23
Certificate of Laboratory Analysis Test Method, Polarized Light Microscopy (PLM) Project: 5969 Newport Project # ABF-16-1799
Report To: Mr. Bill O'brien/ Fred Abdou ABF Environmental 28200 Orchard Lake Rd., Ste. 101 Farmington Hills, MI 48334
Sample Information
ARI Report # Date Collected: Date Received: Date Analyzed: Date Reported:
Asbestos Type/Percent
Lab ID #: 63045 - 32a Cust. #: 10A Material: Mastic Location: Appearance: black,nonfibrous,homogenous Layer: 2 of 2
Asbestos Present: NO No Asbestos Observed
Lab ID #: 63045 - 33 Cust. #: 10B Material: Floor Tile Location: Appearance: of Layer:
Asbestos Present:
Lab ID #: 63045 - 34 Cust. #: 10C Material: Floor Tile Location: Appearance: of Layer:
Asbestos Present:
16-63045 02/15/16 02/17/16 02/22/16 02/22/16
Non-Asbestos Other - 100%
NOT ANALYZED
NOT ANALYZED
For Layered Samples, each component will be analyzed and reported separately.
Robert T. Letarte Jr., Laboratory Director Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.
NVLAP Lab Code 102118-0
APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991
Page 17 of 23
Certificate of Laboratory Analysis Test Method, Polarized Light Microscopy (PLM) Project: 5969 Newport Project # ABF-16-1799
Report To: Mr. Bill O'brien/ Fred Abdou ABF Environmental 28200 Orchard Lake Rd., Ste. 101 Farmington Hills, MI 48334
Sample Information
ARI Report # Date Collected: Date Received: Date Analyzed: Date Reported:
Asbestos Type/Percent
16-63045 02/15/16 02/17/16 02/22/16 02/22/16
Non-Asbestos
Lab ID #: 63045 - 35 Cust. #: 11A Material: Drywall Location: Appearance: grey,fibrous,homogenous Layer: 1 of 2
Asbestos Present: NO No Asbestos Observed
Cellulose - 20% Other - 80%
Lab ID #: 63045 - 35a Cust. #: 11A Material: Joint Compound Location: Appearance: white,nonfibrous,homogenous Layer: 2 of 2
Asbestos Present: NO No Asbestos Observed
Other - 100%
Lab ID #: 63045 - 36 Cust. #: 11B Material: Drywall Location: Appearance: grey,fibrous,homogenous Layer: 1 of 2
Asbestos Present: NO No Asbestos Observed
Cellulose - 20% Other - 80%
For Layered Samples, each component will be analyzed and reported separately.
Robert T. Letarte Jr., Laboratory Director Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.
NVLAP Lab Code 102118-0
APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991
Page 18 of 23
Certificate of Laboratory Analysis Test Method, Polarized Light Microscopy (PLM) Project: 5969 Newport Project # ABF-16-1799
Report To: Mr. Bill O'brien/ Fred Abdou ABF Environmental 28200 Orchard Lake Rd., Ste. 101 Farmington Hills, MI 48334
Sample Information
ARI Report # Date Collected: Date Received: Date Analyzed: Date Reported:
Asbestos Type/Percent
16-63045 02/15/16 02/17/16 02/22/16 02/22/16
Non-Asbestos
Lab ID #: 63045 - 36a Cust. #: 11B Material: Joint Compound Location: Appearance: white,nonfibrous,homogenous Layer: 2 of 2
Asbestos Present: NO No Asbestos Observed
Other - 100%
Lab ID #: 63045 - 37 Cust. #: 11C Material: Drywall Location: Appearance: grey,fibrous,homogenous Layer: 1 of 2
Asbestos Present: NO No Asbestos Observed
Cellulose - 20% Other - 80%
Lab ID #: 63045 - 37a Cust. #: 11C Material: Joint Compound Location: Appearance: white,nonfibrous,homogenous Layer: 2 of 2
Asbestos Present: NO No Asbestos Observed
Other - 100%
For Layered Samples, each component will be analyzed and reported separately.
Robert T. Letarte Jr., Laboratory Director Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.
NVLAP Lab Code 102118-0
APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991
Page 19 of 23
Certificate of Laboratory Analysis Test Method, Polarized Light Microscopy (PLM) Project: 5969 Newport Project # ABF-16-1799
Report To: Mr. Bill O'brien/ Fred Abdou ABF Environmental 28200 Orchard Lake Rd., Ste. 101 Farmington Hills, MI 48334
Sample Information
ARI Report # Date Collected: Date Received: Date Analyzed: Date Reported:
Asbestos Type/Percent
16-63045 02/15/16 02/17/16 02/22/16 02/22/16
Non-Asbestos
Lab ID #: 63045 - 38 Cust. #: 12A Material: Roofing Location: Appearance: black,fibrous,homogenous Layer: 1 of 1
Asbestos Present: NO No Asbestos Observed
Cellulose - 30% Other - 70%
Lab ID #: 63045 - 39 Cust. #: 12B Material: Roofing Location: Appearance: black,fibrous,homogenous Layer: 1 of 1
Asbestos Present: NO No Asbestos Observed
Cellulose - 30% Other - 70%
Lab ID #: 63045 - 40 Cust. #: 12C Material: Roofing Location: Appearance: black,fibrous,homogenous Layer: 1 of 1
Asbestos Present: NO No Asbestos Observed
Cellulose - 30% Other - 70%
For Layered Samples, each component will be analyzed and reported separately.
Robert T. Letarte Jr., Laboratory Director Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.
NVLAP Lab Code 102118-0
APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991
Page 20 of 23
Certificate of Laboratory Analysis Test Method, Polarized Light Microscopy (PLM) Project: 5969 Newport Project # ABF-16-1799
Report To: Mr. Bill O'brien/ Fred Abdou ABF Environmental 28200 Orchard Lake Rd., Ste. 101 Farmington Hills, MI 48334
Sample Information
ARI Report # Date Collected: Date Received: Date Analyzed: Date Reported:
Asbestos Type/Percent
16-63045 02/15/16 02/17/16 02/22/16 02/22/16
Non-Asbestos
Lab ID #: 63045 - 41 Cust. #: 13A Material: Window Caulk Location: Appearance: white,nonfibrous,homogenous Layer: 1 of 1
Asbestos Present: NO No Asbestos Observed
Other - 100%
Lab ID #: 63045 - 42 Cust. #: 13B Material: Window Caulk Location: Appearance: grey,nonfibrous,homogenous Layer: 1 of 1
Asbestos Present: NO No Asbestos Observed
Other - 100%
Lab ID #: 63045 - 43 Cust. #: 13C Material: Window Caulk Location: Appearance: white,nonfibrous,homogenous Layer: 1 of 1
Asbestos Present: NO No Asbestos Observed
Other - 100%
For Layered Samples, each component will be analyzed and reported separately.
Robert T. Letarte Jr., Laboratory Director Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.
NVLAP Lab Code 102118-0
APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991
Page 21 of 23
Certificate of Laboratory Analysis Test Method, Polarized Light Microscopy (PLM) Project: 5969 Newport Project # ABF-16-1799
Report To: Mr. Bill O'brien/ Fred Abdou ABF Environmental 28200 Orchard Lake Rd., Ste. 101 Farmington Hills, MI 48334
Sample Information
ARI Report # Date Collected: Date Received: Date Analyzed: Date Reported:
Asbestos Type/Percent
16-63045 02/15/16 02/17/16 02/22/16 02/22/16
Non-Asbestos
Lab ID #: 63045 - 44 Cust. #: 14A Material: Window Glaze Location: Appearance: brown,nonfibrous,homogenous Layer: 1 of 1
Asbestos Present: NO No Asbestos Observed
Other - 100%
Lab ID #: 63045 - 45 Cust. #: 14B Material: Window Glaze Location: Appearance: brown,nonfibrous,homogenous Layer: 1 of 1
Asbestos Present: NO No Asbestos Observed
Other - 100%
Lab ID #: 63045 - 46 Cust. #: 14C Material: Window Glaze Location: Appearance: brown,nonfibrous,homogenous Layer: 1 of 1
Asbestos Present: NO No Asbestos Observed
Other - 100%
For Layered Samples, each component will be analyzed and reported separately.
Robert T. Letarte Jr., Laboratory Director Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.
NVLAP Lab Code 102118-0
APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991
Page 22 of 23
Certificate of Laboratory Analysis Test Method, Polarized Light Microscopy (PLM) Project: 5969 Newport Project # ABF-16-1799
Report To: Mr. Bill O'brien/ Fred Abdou ABF Environmental 28200 Orchard Lake Rd., Ste. 101 Farmington Hills, MI 48334
Sample Information
ARI Report # Date Collected: Date Received: Date Analyzed: Date Reported:
Asbestos Type/Percent
16-63045 02/15/16 02/17/16 02/22/16 02/22/16
Non-Asbestos
Lab ID #: 63045 - 47 Cust. #: 15A Material: Roofing Location: Appearance: black,fibrous,homogenous Layer: 1 of 1
Asbestos Present: NO No Asbestos Observed
Cellulose - 30% Other - 70%
Lab ID #: 63045 - 48 Cust. #: 15B Material: Roofing Location: Appearance: black,fibrous,homogenous Layer: 1 of 1
Asbestos Present: NO No Asbestos Observed
Cellulose - 30% Other - 70%
Lab ID #: 63045 - 49 Cust. #: 15C Material: Roofing Location: Appearance: black,fibrous,homogenous Layer: 1 of 1
Asbestos Present: NO No Asbestos Observed
Cellulose - 30% Other - 70%
For Layered Samples, each component will be analyzed and reported separately.
Robert T. Letarte Jr., Laboratory Director Test Method EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples tested and to insure the integrity of the results, may only be reproduced in full. This certificate may not be used by the customer to claim product endorsement by NVLAP or any agency of the US Government. APEX Research Inc. is not responsible for the accuracy of the results for layered samples or samples comprising multiple materials. Liability limited to cost of analysis.
NVLAP Lab Code 102118-0
APEX Research Inc., 11054 Hi Tech Drive, Whitmore Lake, MI 48189 (734) 449-9990, Fax (734) 449-9991
Page 23 of 23
APPENDIX C EXHIBITS D, E, H, I, AND SITE DIAGRAM(S)
APPENDIX D SITE PHOTOGRAPHS