MDS Mechanical Pressure Switch
Mechanical Pressure Switches with adjustable switching output for monitoring pneumatic or hydraulic pressure
§ Robust and compact unit § Adjustable switching point § High precision § Up to 5076 psi (350 bar) max. working pressure (more upon request) § Electromechanical signal transducer § M12 and M3 plug connection per DIN EN 175301-803 § Changeover contact function § Long life
DA 13 0203 06/2012 Page 1/6
Buhler Technologies LLC 1030 West Hamlin Road, Rochester Hills, MI 48309 Phone: 248.652.1546 Fax: 248.652.1598 Internet: www.buhlertech.com e-mail:
[email protected]
Technical Specifications MDS Series Mediums
self-lubricating fluids like hydraulic oils and lubricants, compressed air
Mounting position Response
Process connection Gasket seal Fastening torque
G1/8” G1/4” according to DIN3852-E 20 Nm (177 lbf-in) 25 Nm (221 lbf-in)
Switching point Accuracy
Measuring principle
Membrane spring-loaded
Max. operating pressure
Plunger spring-loaded
≤232.1 psi (16 bar) ≤232.1 psi (16 bar) 870.2 psi (60 bar) 5076.3 psi (350 bar)
Materials Gasket Housing
Membrane: NBR Plunger: steel --PTFE, NBR Steel, galvanised steel, galvanised
Switching output Number Switching element
Changer 1 micro switch with silver plated contacts 100/min M3 M12 2A 2A 4A ---
Max. switching frequency Switching power with plug DC to 28 V AC to 250 V
any min. velocity of pressure rise 0.1 psi/s (0.01 bar/s)
Reproducibility
± 2% of range value at room temperature same as accuracy
Ambient conditions Temperature range Environment / operation Vibration resistance Shock resistance
-4...176°F (-20... +80°C) A-10G / 10-500 Hz I-100G/6 ms
Weight
0.3 lb (0,15 kg)
Switch-back difference Plunger type
70
900
60
800
Hysteresis (psi)
40
H min H max
30 20
600 500 400 300
10
200
43,5
72,5
101,5
130,5
159,5
188,5
217,5
100
Switching point (psi)
Plug connection Max. voltage Protection class Cable fitting
725
1450
2175
2900
3625
Switching point (psi)
M3 (DIN EN 175301-803) 3 pol. + PE 250V IP65 PG9
M12 (socket) 4 pol. 28V IP67** **when connected
Pin assignment
p
DA 13 0203 06/2012 Page 2/6
3
4
2
2
1
p
1
4350
F001007
0 14,5
H min H max
700
50
F001007
Hysteresis (psi)
Membrane Type
Dimensions in mm Version M3
GL
Version M12
G GL 1/8 0.39 in 1/4 0.47 in
G
F000648
Accessories:
Part no.: 9144050047 Connecting cable M12x1, 4-pin, L = 5 m (195 in) Part no.: 9146100159 Contact box M12x1, 90° angle
Product code for MDS MDS -
-
-
Pressure ranges Setting of switching point 1) (optional)
Model Connector M3 or M12 Fluid Port G1/8” or G1/4”
1)
Pressure ranges 8: 0.5...8 bar (7.3...116 psi) 16: 1...16 bar (14.5...232 psi) 120: 10...120 bar (145...1740 psi) 250: 20...250 bar (290...3625 psi) 320: 30...320 bar (435...4640 psi)
Membrane pressure switch Membrane pressure switch Piston pressure switch Piston pressure switch Piston pressure switch
If required, the switching point setting can be executed by the factory. The switching point must be set for rising or falling pressure, i.e. switching point monitoring of 0 bar to switching point (rising) or from max. operating pressure decreasing to switching point (falling). Refer to the following example for the circuitry: MDS-M3-G1/4-120-80R (switching point 80 bar (1160 psi) rising) PIN3-2 closed when switching point is reached MDS-M3-G1/4-120-80F (switching point 80 bar (1160 psi) falling) PIN3-1 closed when switching point is reached
DA 13 0203 06/2012 Page 3/6
we reserve the right to amend specifications
Technical Specifications MDSM & MDSK Series Mediums
MDSM Neutral fluids, compressed air
Process connection
G1/4” inside
Mounting position Measuring principle Max. operating pressure Min. velocity of pressure rise Switching point Accuracy/reproduciblity
any Spring-loaded membrane 870.2 psi (60 bar) 0.1 psi/s (0.01 bar/s)
MDSK self-lubricating fluids such as hydraulic oils and lubricants G 1/4” rotary, vertical flange DIN ISO 16873 Fastening torque: 25 Nm any Spring-loaded piston 5076.3 psi (350 bar) 0.1 psi/s (0.01 bar/s)
± 2% of range value at room temperature
± 2% of range value at room temperature
Materials Measuring element Pressure connection
membrane: NBR zinc die cast (G1/4” inside)
Housing
zinc die cast
piston: stainless steel 1.4305 galvanised steel (G1/4” rotary), zinc die cast (vertical flange) zinc die cast
Switching output Number Switching element Max. switching frequency Max. switching power with plug DC to 28V AC to 250V
Changer 1, adjustable with lock micro switch with silver plated contacts 200 / min.
Changer 1, adjustable with lock micro switch with silver plated contacts 200 / min.
M3 3A 6A
M3 3A 6A
Ambient conditions Temperature range Environment/operation Vibration resistance Shock resistance
14...176 °F (-10 °C...+80 °C) A-10G/10-500 Hz I-100G/6 ms
14...176 °F (-10 °C...+80 °C) A-10G/10-500 Hz I-100G/6 ms
Weight
0.7 lb (0,3 kg)
0.7 lb (0,33 kg)
M12 3A ---
M12 3A ---
Switch-back difference: MDSK
MDSM 20,00 400
14,00 12,00
MDSM 16 MDSM 8 MDSM 2
10,00 8,00 6,00 4,00 2,00 0,00 43,50
87,00
130,50
174,00
217,50
350 300 250 200 150 100 0
725
Switching point (psi)
Plug connection Max. voltage Protection class Cable fitting
1450
2175
2900
3625
4350
Switching point (psi)
M3 (DIN EN 175301-803) 3 pol. + PE 250V IP65 PG9
M12 (Socket) 4 pol. 28V IP67** **when connected
Pin assignment DA 13 0203 06/2012 Page 4/6
3
2
p
1
4
2
p
1
F001006
Switch-back difference (psi)
16,00
F001007
Switch-back difference (psi)
18,00
Dimensions in mm MDSM
Version M12
Version M3 Contact box included
Female thread fixed Female thread fixed
MDSK Version M3 Contact box included
G GL 1/4 0.47 in Male thread twistable
Version M12
Vertical flange DIN ISO 16873
Male thread twistable
Accessories: DA 13 0203 06/2012 Page 5/6
Art-Nr.: 9144050047 Connecting cable M1 2x1, 4-pin plug, L = 5m (195 in) Art-Nr.: 9146100159 Contact box M1 2x1, 90° angle Art-Nr.: 9008429 Double nipple G1/4, stainless steel we reserve the right to amend specifications
Product code MDS
-
-
-
-
Model M MDSM K MDSK
Pressure ranges Setting of switching point 1)
Plug connection M3 or M12
Pressure ranges 8 : 0,5...8 bar 16: 1...16 bar 120: 10...120 bar 250: 20...250 bar 320: 30...320 bar
G1/4i G1/4” inside (MDSM only) G1/4d G1/4” twistable (MDSK only) VF Vertical flange per ISO 16873 (MDSK only)
1)
(7.3...116 psi) (14.5...232 psi) (145...1740 psi) (290...3625 psi) (435...4640 psi)
MDSM MDSM MDSK MDSK MDSK
If required, the switching point setting can be executed by the factory. The switching point must be set for rising or falling pressure, i.e. switching point monitoring of 0 bar to switching point (rising) or from max. operating pressure decreasing to switching point (falling). Refer to the following example for the circuitry: MDSK-M3-G1/4-120-80R (switching point 80 bar rising) PIN1-3 closed when switching point is reached MDSK-M3-G1/4-120-80F (switching point 80 bar falling) PIN1-2 closed when switching point is reached
DA 13 0203 06/2012 Page 6/6