Flow Controls FLow control functions for applications up to 350 bar (5000 psi) and 350 L/min (92 USgpm)

H

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-1.A

Flow Controls Valve locator

Functional Symbol

Model Cavity

2

1

2

2

1

3

1

H

2

3

1

2

2 (EF)

4 (CF)

2

1

5(LS)

3 (P) 4 (CF)

Typical Pressure

Page

Flow regulator valve, fixed





L/min (USgpm)

bar (psi)

FR5-8 FR5-10 FR1-16 FR1-20

C-8-2 C-10-2 C-16-2 C-20-2



10 (25) 23 (6) 114 (30) 227 (60)



280 (4000) 280 (4000) 210 (3000) 210 (3000)

H-100 H-110 H-120 H-130

Flow Rating

Typical Pressure

Page

Model Cavity

1

Flow Rating

Flow regulator valve, adjustable





L/min (USgpm)

bar (psi)

FR2-10 FR2-16

C-10-2 C-16-2



38 (10) 114 (30)

210 (3000) 210 (3000)

H-140 H-150

Model Cavity

Flow Rating

Typical Pressure

Page

Flow regulator with check





L/min (USgpm)

bar (psi)

2CFRC60 FAR1-10 FAR1-12 FAR1-16

A7447 C-10-2 C-12-2(u) C-16-2

4-60 (1-16) 1-38 (0.25-10) 1.5-95 (0.4-25) 3.8-114 (1-30)

350 (5000) 310 (4500) 310 (4500) 310 (4500)

H-160 H-170 H-180 H-190

Model Cavity

Flow Rating

Typical Pressure

Page

Priority flow regulator, bypass, fixed





L/min (USgpm)

bar (psi)

PFR5-8 PFR5-10 PFR15-10 PFR11-12 PFR11-16

C-8-3 C-10-3 C-10-3 C-12-3 C-16-3



<10 (2.5) <23 (6) <38 (10) <30 (8) <114 (30)

280 (4000) 280 (4000) 350 (5000) 350 (5000) 350 (5000)

H-200 H-210 H-220 H-230 H-240

Model Cavity

Flow Rating

Typical Pressure

Page

Priority flow regulator, bypass, adjustable



L/min (USgpm)

bar (psi)

2CFP60 PFR12-0 PFR12-12 PFR2-16 PFR12-16

CVA-27-04-0 C-10-3 C-12-3 C-16-3 C-16-3

<60 (16) <64 (17) <45 (12) <114 (30) <114 (30)

350 (5000) 350 5000) 350 (5000) 210 (3000) 350 (5000)

H-250 H-254 H-260 H-270 H-280

Model Cavity

Flow Rating

Typical Pressure

Page

Priority flow regulator



L/min (USgpm)

bar (psi)

PFRD/S-12 PFRD/S-16 PFRD/S-20

C-12-5S C-16-5S C-20-5S

76 (20) 150 (40) 230 (60)

280 (4000) 280 (4000) 240 (3500)





H-290 H-300 H-310

2 (EF) 2

1

5(LS)

3 (P) Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-2.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

Flow Controls (cont.) Valve locator

Functional Symbol

2

1

1

Model Cavity

Flow Rating

Typical Pressure

Manual rotary flow restrictor





L/min (USgpm)

bar (psi)

MRV2-10 MRV2-16

C-10-2 C-16-2



<56 (15) <170.3 (45)

210 (3000) 210 (3000)

H-320 H-330

Model Cavity

Flow Rating

Pressure

Page

Needle valve





L/min (USgpm)

bar (psi)

2CR80

A7447



<80 (20)

350 (5000)

H-340

Model Cavity

Flow Rating

Typical Pressure

Page

Page

2

1

2

1

Needle valve



L/min (USgpm)

bar (psi)

NV1-8 NV1-10 FCV7-10 FCV11-12 FCV6-16

C-8-2 C-10-2 C-10-2 C-12-2(u) C-16-2

<45 (12) <45 (12) <45 (12) <114 (30) <208 (55)

280 (4000) 210 (3000) 210 (3000) 350 (5000) 210 (3000)

H-342 H-350 H-380 H-390 H-400

Model Cavity

Flow Rating

Typical Pressure

Page

Needle valve





L/min (USgpm)

bar (psi)

NV1-16 NV1-20

C-16-2 C-20-2



<151 (40) <265 (70)

210 (3000) 210 (3000)



H-360 H-370

2

3

2

1

1

2

4

3

H Model Cavity

Flow Rating

Typical Pressure

Pressure compensator, restrictive





L/min (USgpm)

bar (psi)

PCS3-10 PCS13-10 PCS3-12 PCS13-12 PCS3-16 PCS13-16 PCS3-20

C-10-3 C-10-3 C-12-3 C-12-3 C-16-3 C-16-3 C-20-3



<38 (10) <38 (10) <58 (15) <58 (15) <114 (30) <114 (30) <189 (50)

210 (3000) 350 (5000) 240 (3500) 350 (5000) 210 (3000) 350 (5000) 210 (3000)

H-410 H-420 H-430 H-440 H-450 H-460 H-470

Model Cavity

Flow Rating

Typical Pressure

Page

Pressure compensator bypass/priority





L/min (USgpm)

bar (psi)

PCS4-10 PCS14-10 PCS4-12 PCS14-12 PCS4-16 PCS14-16 PCS4-20

C-10-4 C-10-4 C-12-4 C-12-4 C-16-4 C-16-4 C-20-4



<38 (10) <38 (10) <58 (15) <58 (15) <114 (30) <114 (30) <189 (50)

210 (3000) 350 (5000) 240 (3500) 350 (5000) 210 (3000) 350 (5000) 210 (3000)

Page

H-480 H-490 H-500 H-510 H-520 H-530 H-540

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-3.A

Flow Controls (cont.) Valve locator

Functional Symbol Reg. (2)

Inlet (1)

Model Cavity

Flow Rating

Typical Pressure

Flow regulator/diverter





L/min (USgpm)

bar (psi)

2FPH55 2FPH95 2FPH195





<55 (14) <95 (25) <160 (42)

280 (4000) 350 (5000) 350 (5000)

H-550 H-550 H-550

Model Cavity

Flow Rating

Typical Pressure

Page

Page

By-pass (3) Drain (4)

LS Reg.

Inlet

By-pass

Flow regulator/diverter





L/min (USgpm)

bar (psi)

2FPH250 2FPH350





<200 (52) <350 (92)

350 (5000) 350 (5000)

H-560 H-560

Model Cavity

Flow Rating

Typical Pressure

Page

Drain

fusing direction

reverse flow direction

2

1

2

4

H 3 3

2

1 2

4

Flow fuse





L/min (USgpm)

bar (psi)

VF1-10 VF11-1O VF1-16

C-10-2 C-10-2 C-16-2



23 (6) 23 (6) 114 (30)

210 (3000) 350 (5000) 210 (3000)

H-570 H-570 H-580

Model Cavity

Flow Rating

Typical Pressure

Page

Flow divider/conbiner



L/min (USgpm)

bar (psi)

FDC1-16 FDC11-16 2CFD50 2CFD200

C-16-4 C-16-4 A12744 CVB-42-04-0

<178 (47) <140 (37) <40 (10.5) <220 (58)

210 (3000) 350 (5000) 350 (5000) 280 (4000)

H-590 H-600 H-610 H-620

Model Cavity

Flow Rating

Typical Pressure

Page

Flow divider/combiner





L/min (USgpm)

bar (psi)

FDC1-20

Inline



<141 (37)

210 (3000)

H-630

Model Cavity

Flow Rating

Typical Pressure

Page



Flow divider/combiner, posi-traction





L/min (USgpm)

bar (psi)

FDC3-16

C-16-4



<152 (40)

210 (3000)

H-640

Model Cavity

Flow Rating

Typical Pressure

Page

Flow divider/combiner, posi-traction





L/min (USgpm)

bar (psi)

FDC3-20

Inline



<570 (150)

210 (3000)

3 3

2

H-650

1

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-4.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

Flow Controls Section Overview

This section gives basic specifications for the complete line of Eaton's Integrated Hydraulics threaded cartridge flow control valves. Its purpose is to provide a quick, convenient reference tool when choosing cartridge valves or designing a system using these components.

• Flow divider/combiners (FDC1 and FDC11) with flows rated to 568 L/min (150 USgpm). • Posi-traction valves (FDC13) with flows rated to 567 L/ min (150 USgpm) • Operating pressures to 350 bar (5000 psi).

Valve Features and Benefits

Here are some of the benefits of Eaton flow controls:

Eaton offers a complete range of Integrated Hydraulics flow controls cartridge valves, with a variety of features, including:

• All operating parts are hardened steel, ground and honed for long life and low leakage.

• Products in this catalog have been Fatigue tested to one million cycles at 132% or 10 million cycles at 115% of rated pressure.

• Designed for maximum flexibility and minimal space requirements.

• Non-adjustable, pressure compensated, flow regulator for flows to 227 L/min (60 USgpm). • Adjustable, pressure compensated, flow regulator for flows to 114 L/min (30 USgpm). • Fixed and adjustable priority bypass type flow regulator for regulated flows to 114 L/min (30 USgpm). • Adjustable flow control without free reverse flow check with flows rated to 114 L/min (30 USgpm). • Adjustable flow control with free reverse flow check with flows rated to 45 L/min (12 USgpm). • Needle valves with flows rated to 265 L/min (70 USgpm). • Velocity fuses with flows rated to 227 L/min (60 USgpm).

• All exposed cartridge surfaces are zinc dichromate plated to resist corrosion. Steel housings are available for cartridges rated to 350 bar (5000 psi) application pressures. • All aluminum manifolds are gold anodized to resist corrosion.

FDC1/FDC11

FDC3/FDC13

The FDC*1 is a cartridge type hydraulic flow divider-combiner valve. It divides and combines flow, regardless of system load or pressure, proportionally per specified flow division.

The FDC*3 is a cartridge type positive traction valve that divides and combines flow, regardless of system load or pressure, proportionally per specified flow division.

For example: FDC*1-10-*–66 will divide an incoming flow of 45 L/min (12 USgpm) equally out each port with an accuracy of 10% each side. With 45 L/min (12 USgpm) in at “3” port, flow out port “4” can be 22 L/min (6 USgpm) 4,5 L/min (1.2 USgpm) while flow at port “2” is 22,7 L/min (6 USgpm) 4,5 L/min (1.2 USgpm).

This valve is used in place of a standard flow dividercombiner in systems where hydraulic motors are used as drive wheels on each side of the machine. The positive traction valve acts much like a standard flow divider-combiner as the vehicle travels in a straight line. Equal amounts of flow go to each “C” port. As the vehicle turns a corner, a standard flow divider will maintain equal flow to each drive motor. On a turn, it is necessary for the outer wheel to turn faster than the inner wheel. A standard flow dividercombiner will provide equal flow to each motor causing the drive motors to skid. The positive traction valve solves this problem by allowing the one motor to turn faster than the other.

The combining accuracy is the same with incoming flow at port “4” and “2” and flow out port “3” of 45 L/min (12 USgpm). Inlet flow at port “4” will be 22 L/min (6 USgpm) 4,5 L/min (1.2 USgpm). Inlet flow at port “2” will be 22 L/ min (6 USgpm) 4,5 L/min (1.2 USgpm). Flow division or combining will be maintained even if unequal loads are placed on ports “4” and “2”.

• Reliable, economical and compact. • Low leakage. • Variety of adjustment options. • Adjustments designed not to go spring solid at “full in” position or to allow the adjustment to be removed when backed out. Notable are the two styles of flow divider/combiner:

A special feature of the FDC*1–** is that it provides rephase flow to either port 2 or port 4 when one of the two is blocked. This feature is useful in hydraulic circuits that require cylinders to move at the same time. If one cylinder bottoms out first, the opposite cylinder is provided with “rephase” flow to allow the cylinder to bottom and start the cylinders together for movement in the opposite direction.

This operates in a similar way as a mechanical differential on an automobile. In a turn, the inside drive motor is restricted and builds up pressure, while the outside drive motor is without restriction. Under conditions of high differential pressure, the positive traction valve passes extra flow to the least restricted motor to prevent skidding. Under straight running conditions the differential pressure is low and equal amounts of flow are provided to each drive motor.

WARNING For pressure over 210 bar (3000 psi) use steel housing.



Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-5.A

H

2FBAR

2FR

2FBAR

Adjustments 2FR

SPEED CONTROL SPEED CONTROL

MOTOR CONTROL MOTOR CONTROL

TWO-SPEED CIRCUIT TWO-SPEED CIRCUIT

STEERING MOTOR STEERING MOTOR

Adjustments The adjustment range and Max setting figures shown throughout this catalog give the design range for each valve, higher or lower values may be attainable but should not be used without first contacting our Engineering department. Setting must ALWAYS be carried out using and appropriate gauge and it must NOT be ADJUSTMENTS ADJUSTMENTS assumed that screwing an adjuster to its maximum or minimum position will yield the maximum or minimum stated design setting for that valve.

The adjustment and setting Max setting figures throughout this catalogue givedesign the design for each The adjustment rangerange and Max figures shownshown throughout this catalogue give the rangerange for each valve,valve, or lower may be attainable but should be used without first contacting our Engineering department. higherhigher or lower valuesvalues may be attainable but should not benot used without first contacting our Engineering department. Setting ALWAYS be carried out using an appropriate it must NOT be assumed that screwing Setting must must ALWAYS be carried out using an appropriate gaugegauge and itand must NOT be assumed that screwing an an adjuster its maximum or minimum position will the yieldmaximum the maximum or minimum design setting forvalve. that valve. adjuster to its to maximum or minimum position will yield or minimum statedstated design setting for that Alternative Adjusters

ø36.50

‘P’ - LEAKPROOF SCREW ‘P’ - LEAKPROOF SCREW

9 10

ø60.00

2FP952FP95 2FB952FB95 2FR952FR95 2FRC95 2FRC95 2FBAR95 2FBAR95

LINEAR ADJUSTMENT THROUGH . VARIABLE TO GIVE LINEAR ADJUSTMENT THROUGH 180° . 180° VARIABLE TO GIVE 1 TO 95 LITRES/MIN THE ABILITY TOASET A MAXIMUM 1 TO 95 LITRES/MIN WITH WITH THE ABILITY TO SET MAXIMUM BETWEEN THESE FLOWS BETWEEN THESE FLOWS

Available Available only only on: on:

ø60.00

49.00 MAX

75.0 MAX

75.0 MAX

9 10

‘R’ - HANDKNOB ‘R’ - HANDKNOB Available Available only only on: on:

H

ø36.50

49.00 MAX

133.5 MAX133.5 MAX

99

2FP952FP95 2FB952FB95 2FR952FR95 2FRC95 2FRC95 2FBAR95 2FBAR95

11 POSITIVE POSITIONS 320° ROTATION 11 POSITIVE POSITIONS 320° ROTATION

‘L’ - LEVER ‘L’ - LEVER

‘D’ - DETENT ‘D’ - DETENT

Integrated Hydraulics Integrated Hydraulics Ltd Ltd

Heathcote Ind.Warwick, Est., Warwick, 6TF, UK. CollinsCollins Road, Road, Heathcote Ind. Est., CV34 CV34 6TF, UK. Tel:(0) +44 (0) 881171 1926 881171 Fax:(0) +44 (0) 315729 1926 315729 Tel: +44 1926 Fax: +44 1926 Website: www.integratedhydraulics.com Website: www.integratedhydraulics.com

9-102.C 9-102.C

Integrated Hydraulics Integrated Hydraulics Inc Inc

7047 Spinach Mentor, Ohio 44060, 7047 Spinach Drive, Drive, Mentor, Ohio 44060, USA USA Tel: 974 (440)3171 974 3171 Fax: 974 (440)3170 974 3170 Tel: (440) Fax: (440) Website: www.integratedhydraulics.com Website: www.integratedhydraulics.com

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-6.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

- Additional products, product lines, and services offered by Eaton -

H

Accessibility Char-Lynn Motors

Ease of Doing Business • Expanded Eaton.com

• Products Catalog

• Char-Lynn Service and Repair

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-7.A

FR5-8 - Flow Regulator Fixed pressure compensated 10 L/min (2.5 USgpm) • 280 bar (4000 psi)

2

1

Sectional View

Operation

Features

This valve maintains a constant flow from port 1 to port 2 based on 5.5 bar(80 psid) regardless of pressure changes downstream on port 2. Reverse flow from port 2 to port 1 is at the value of the fixed orifice and is nonpressure compensated.

Hardened and ground and honed working components. Cartridge construction for maximum mounting flexibility.

Performance Data Ratings and Specifications

Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F) Typical application pressure (all ports) 350 bar (5000 psi) steel housing 210 bar (3000 psi) aluminum housing Cartridge fatigue pressure (infinite life) 280 bar (4000 psi) Rated flow 10 L/min (2.5 USgpm) Temperature range –40° to 120°C (–40° to 248°F) Flow regulation accuracy 0,4–1,9 L/min (0.1–0.49 USgpm) 20% @ 210 bar (3000 psi) 0,4–1,9 L/min (0.1–0.49 USgpm) 40% @ 350 bar (5000 psi) 1,9 – 5,7 L/min (0.5–1.49 USgpm) 15% 5,7–10 L/min (1.5–2.5 USgpm) 10%

2

H

1

Factory set maximum flow rate accuracy under standard test conditions and within the above ranges

Cavity Fluids Filtration Standard housing material Weight cartridge only Seal kit

C-8-2 All general purpose hydraulic fluids such as MIL-H-5606, SAE 10, SAE 20 etc. Cleanliness code 18/16/13 Aluminum or steel 0,05 kg (0.12 lbs) 02–165875 (Buna-N) 02–165877 (Viton®)

Viton is a registered trademark of E.I. DuPont

Description

Typical Flow Regulation

This is a fixed orifice, pressure compensated, restrictive flow regulator screw-in cartridge valve.

Cartridge only 70

Pressure - bar 140 210

350 10

2.5 Flow - USgpm (105 SUS oil @ 120°F)

280

A 8

2.0

6

1.5

4

1.0

B

0.5 0

Flow - L/min (21,8 cSt oil @ 49°C)

3.0

0

2

C 0

1000

2000

3000

4000

5000

Pressure - psi

A - 9,5 L/min (2.5 USgpm) B - 1,9 L/min (0.5 USgpm) C - 0,38 L/min (0.1 USgpm)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-100.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

FR5-8 - Flow Regulator Fixed pressure compensated 10 L/min (2.5 USgpm) • 280 bar (4000 psi)

Model Code

FR 5 – 8



1 1

6

Function

FR5 - Flow regulator

2

Size

8 - 8 Size

3

Seal Material

Blank - Buna-N V- Viton®

4

(V) – F

2

3

– (*)

4

5

** – *.* – 00 6

7

Port Size

7 Factory Set Flow Rate, Nominal

Code

Port Size

Housing Number

0 4T 6T 8T 2G 3G

Cartridge only SAE 4 SAE 6 SAE 8 1/4" BSPP 3/8" BSPP

Aluminium Fatigue rated

Steel Fatigue rated

02–160730 02–160731 02–160732 02–160727 02–160728

02–160736 02–160737 02–160738 02–160733 02–160734

See section J for housing details.

Adjustment

8

(Specify in USgpm) Range 0,4-9,5 L/min (0.1–2.5 USgpm)

8 Special features 00 - None (Only required if valve has special features, omitted if “00") SS - 316 Stainless Steel external components

F - Fixed orifice

5

Valve Housing Material

Omit for cartridge only A - Aluminum S - Steel

Dimensions

Torque cartridge in steel or aluminum housing 34-41 Nm (25-30 ft lbs).

mm (inch) Cartridge Basic Code FR5-8

Installation Drawing (Steel)

9.1 (.36)

8,6 (0.34)

22,1 (.870) hex 0.750" -16 Thd.

27,8 (1.09)

Ø12,62 (0.497)

H 15.5 (0.61) 19.1 (0.75)

19.1 (0.75)

50.8 (2.00)

38.1 (1.50)

2

1

3.4 (0.13)

44.0 (1.734) 50.8 (2.00)

2 x 7.1 (0.3281)

38.1 (1.50)

WARNING Aluminum housings can be used for pressures up to 210 bar (3000 psi). Steel housings must be used for operating pressures above 210 bar (3000 psi).



Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-101.A

FR5-10 - Flow Regulator Fixed, pressure compensated 23 L/min (6 USgpm) • 280 bar (4000 psi)

2

1

Operation

Features

This valve maintains a constant flow from port 1 to port 2 based on 5.5 bar(80 psid) regardless of pressure changes downstream on port 2. Reverse flow from port 2 to port 1 is at the value of the fixed orifice and is nonpressure compensated.

Hardened and ground and honed working components. Cartridge construction for maximum mounting flexibility.

Performance Data

Sectional View

Ratings and Specifications

Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F) Typical application pressure (all ports) 350 bar (5000 psi) steel housing Cartridge fatigue pressure (infinite life) 280 bar (4000 psi) Rated flow 23 L/min (6 USgpm) Temperature range –40° to 120°C (–40° to 248°F) Flow regulation accuracy 0,38–1,9 L/min (0.1–0.49 USgpm) ±20% @ 210 bar (3000 psi) 0,38–1,9 L/min (0.1–0.49 USgpm) ±40% @ 350 bar (5000 psi) 1,9 – 5,7 L/min (0.5–1.49 USgpm) ±15% @ 350 bar (5000 psi) 5,7–22,7 L/min (1.5–6 USgpm) ±10% @ 350 bar (5000 psi) Factory set maximum flow rate accuracy under standard test conditions and within the above ranges

H 1

C-10-2 All general purpose hydraulic fluids such as MIL-H-5606, SAE 10, SAE 20 etc. Cleanliness code 18/16/13 Aluminum or Steel 0,12 kg (0.26 lbs) 565803 (Buna-N) 566086 (Viton®)

Viton is a registered trademark of E.I. DuPont

Description

Typical Flow Regulation

This is a fixed orifice, pressure compensated, restrictive flow regulator screw-in cartridge valve.

Cartridge only Differential pressure - bar

Flow - USgpm (105 SUS oil @ 120°F)

6

0

70

140

210

280

350

A

5

20 16

B

4 3

24

12

C

8

2

4

D

1 0

1000

2000

3000

4000

5000

Flow - L/min (21,8 cSt oil @ 49°C)

2

Cavity Fluids Filtration Standard housing material Weight cartridge only Seal kit

0

Differential pressure - psi

A – 21 L/min (5.5 USgpm) B – 13,3 L/min (3.5 USgpm)

C – 7,8 L/min (2.0 USgpm) D – 0,95 L/min (0.25 USgpm)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-110.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

FR5-10 - Flow Regulator Fixed, pressure compensated 23 L/min (6 USgpm) • 280 bar (4000 psi)

Model Code

FR 5 – 10



1 1

6

Function

FR5 - Flow regulator

2

Size

10 - 10 Size

3

Seal Material

Blank - Buna-N V - Viton®

4

Adjustment

F - Fixed orifice

5

2

(V) – F – (*) 3

4

5

** – *.* – 00 6

Port Size

7

8

7

Code

Port Size

Housing Number

0 3B 2G 3G 6H 8H 6T 8T

Cartridge only 3/8" BSPP 1/4" BSPP 3/8” BSPP SAE 6 SAE 8 SAE 6 SAE 8

Aluminium Light duty

Aluminium Fatigue rated

Steel Fatigue rated

02–175462 – – – – 566151 –

– 876702 876703 876700 876701 – –

– 02-175102 02-175103 – – 02-175100 02-175101

Factory Set Flow Rate

(Specify in USgpm) Range 0,4-9,5 L/min (0.1-2.5 USgpm)

8

Special Features

00 - None (Only required if valve has special features, omitted if “00”)

See section J for housing details.

Valve Housing Material

Omit for cartridge only A - Aluminum S - Steel

Dimensions

Torque cartridge in housing A - 47-54 Nm (35-40 ft lbs) S - 68-75 Nm (50-55 ft lbs)

mm (inch) Cartridge Basic Code FR5-10

H

Installation Drawing (Steel) 21.6 (0.85)

20,8 (0.82)

25,4 (1.00) hex 2 63.5 (2.50)

0.875”-14 Thd. 31,7 (1.25)

50.8 (2.00)

19 (0.75) 1

2 9.5 (0.37)

44.5 (1.75)

22.2 (0.87) 44.45 (1.750)

2 X Ø7.14 (0.281)

63.5 (2.50)

1 Ø15,82 (0.623)

WARNING Aluminum housings can be used for pressures up to 210 bar (3000 psi). Steel housings must be used for operating pressures above 210 bar (3000 psi).



Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-111.A

FR1-16 - Flow Regulator Fixed, pressure compensated 114 L/min (30 USgpm) • 210 bar (3000 psi)

2

1

Sectional View

Operation

Features

This valve maintains a constant flow from port 1 to port 2 based on 5.5 bar(80 psid) regardless of pressure changes downstream on port 2. Reverse flow from port 2 to port 1 is at the value of the fixed orifice and is nonpressure compensated.

Hardened and ground and honed working components. Cartridge construction for maximum mounting flexibility.

Performance Data Ratings and Specifications

Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F) Typical application pressure (all ports) 210 bar (3000 psi) Cartridge fatigue pressure (infinite life) 210 bar (3000 psi) Rated flow 114 L/min (30 USgpm) Temperature range –40° to 120°C (–40° to 248°F) Flow regulation accuracy 1,9–10,9 L/min (0.5–2.9 USgpm) ±15% 11,4–114 L/min (3–30 USgpm) ±10% Factory set maximum flow rate accuracy under standard test conditions and within the above ranges

2

H

Cavity Fluids Filtration Standard housing material Weight cartridge only Seal kit

C-16-2 All general purpose hydraulic fluids such as MIL-H-5606, SAE 10, SAE 20 etc. Cleanliness code 18/16/13 Aluminum 0,33 kg (0.72 lbs) 565810 (Buna-N) 880609 (Viton®)

Viton is a registered trademark of E.I. DuPont

1

Description

Typical Flow Regulation

This is a fixed orifice, pressure compensated, restrictive flow regulator screw-in cartridge valve.

Cartridge only Pressure - bar 70

140

210

A

30

140 120 100

25

80

20 B

15 10

60 40

C

5

20

Flow -L/min (21,8 cSt oil @ 49°C)

Flow - USgpm (105 SUS oil @ 120°F)

35

0

0

0 0

1000 2000 Pressure - psi

3000

A - 114 L/min (30.0 USgpm) B - 60 L/min (15.0 USgpm) C - 9,5 L/min (2.5 USgpm)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-120.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

FR1-16 - Flow Regulator Fixed, pressure compensated 114 L/min (30 USgpm) • 210 bar (3000 psi)

Model Code

FR 1 – 16



1 5

1 Function FR1 - Flow regulator

2

Size

16 - 16 Size

3

Seal Material

Blank - Buna-N V - Viton®

4

Adjustment

(V) –

2

3

*** – *.* – 00

4

5

6

7

Port Size

6

Factory Set Flow Rate, Nominal

Code

Port Size

Housing Number

0 6B 12T 4G 6G 10H 12H

Cartridge only 3/4" BSPP SAE 12 1/2" BSPP 3/4" BSPP SAE 10 SAE 12

Aluminium Light duty

Aluminium Fatigue rated

(Specify in USgpm) Range 1,9-114 L/min (0.5-30 USgpm)

02–175463 566149 – – – –

– – 876716 876718 876717 566113

00 - None (Only required if valve has special features, omitted if “00”)

F - Fixed orifice

See section J for housing details.

Dimensions

Torque cartridge in aluminum housing to 108-122 Nm (80-90 ft lbs)

mm (inch)

F

Cartridge Basic Code FR1-16

7

Special Features

Installation Drawing

28,6 (1.12)

44,4 (1.75)

28.4 (1.12)

28.6 (1.13)

38,1 (1.50) hex

1.312" -12 Thd.

H

31.8 (1.25)

88.9 (3.50)

2

63.5 (2.50)

1

2 10.3 (0.41)

68.28 (2.688) 88.9 (3.50)

2 x 8.74 (0.344) 63.50 (2.500)

1 Ø28,55 (1.124)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-121.A

FR1-20 - Flow Regulator

Fixed, pressure compensated 227 L/min (60 USgpm) • 210 bar (3000 psi)

2

1

Sectional View

Operation

Features

This valve maintains a constant flow from port 1 to port 2 based on 5.5 bar(80 psid) regardless of pressure changes downstream on port 2. Reverse flow from port 2 to port 1 is at the value of the fixed orifice and is nonpressure compensated.

Hardened and ground and honed working components. Cartridge construction for maximum mounting flexibility.

Performance Data Ratings and Specifications

Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F) Typical application pressure (all ports) 210 bar (3000 psi) Cartridge fatigue pressure (infinite life) 210 bar (3000 psi) Rated flow 227 L/min (60 USgpm) Temperature range –40° to 120°C (–40° to 248°F) Flow regulation accuracy 3,8–18,5 L/min (1–4.9 USgpm) ±15% 19–227 L/min (5–60 USgpm) ±10% Factory set maximum flow rate accuracy under standard test conditions and within the above ranges

2

H

Cavity Fluids Filtration Standard housing material Weight cartridge only Seal kit

C-20-2 All general purpose hydraulic fluids such as MIL-H-5606, SAE 10, SAE 20 etc. Cleanliness code 18/16/13 Aluminum 0,82 kg (1.8 lbs) 889615 (Buna-N), 889619 (Viton®)

Viton is a registered trademark of E.I. DuPont

1

Description

Typical Flow Regulation

This is a fixed orifice, pressure compensated, restrictive flow regulator screw-in cartridge valve.

Cartridge only Pressure - bar

Flow - USgpm (105 SUS oil @ 120°F)

140

210

280 240

A

200 160

B

120 80

C

10 0

40 0

1000

2000

3000

Flow - L/min (21,8 cSt oil @ 49°C)

70

0 70 60 50 40 30 20

0

Pressure - psi

A - 227 L/min (60.0 USgpm) B - 114 L/min (30.0 USgpm) C - 38 L/min (10.0 USgpm)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-130.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

FR1-20 - Flow Regulator

Fixed, pressure compensated 227 L/min (60 USgpm) • 210 bar (3000 psi)

Model Code

FR 1 – 20



1 1

5

Function

FR1 - Flow regulator

2

Size

20 - 20 Size

3

Seal Material

Blank - Buna-N V- Viton®

4

Adjustment

(V) –

2

3

4

5

6

7

Port Size

6

Code

Port Size

Housing Number

0 6B 12T 4G 6G 10H 12H

Cartridge only 3/4" BSPP SAE 12 1/2" BSPP 3/4" BSPP SAE 10 SAE 12

Aluminium Light duty

Aluminium Fatigue rated

02–175464 566409 – – – –

– – 876732 876734 876733 876735

F - Fixed orifice

See section J for housing details.

Dimensions

Torque cartridge in aluminum housing to 128-155 Nm (95-115 ft lbs)

mm (inch)

F – *** – *.* – 00

Cartridge Basic Code FR1-20

Factory Set Flow Rate, Nominal

(Specify in USgpm) Range 3.8-277 L/min (1-60 USgpm)

7

Special Features

00 – None (Only required if valve has special features, omitted if “00”)

Installation Drawing

28,6 (1.12)

H 36.0 (1.42)

41.3 (1.62)

38,1 (1.50) hex

41.3 (1.62)

1.312" -12 Thd. 44,4 (1.75)

101.6 (4.00)

2

2

76.2 (3.00)

1

10.3 (0.41)

1 Ø28,55 (1.124)

80.98 (3.188) 101.6 (4.00)

2 x 8.74 (0.344) 82.55 (3.250)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-131.A

FR2-10 - Flow Regulator Limited range, adjustable pressure compensated 38 L/min (10 Usgpm) • 210 bar (3000 psi)

Operation 2

1

Sectional View

Features

This valve maintains a constant flow from port 1 to port 2 based on the setting adjustment, regardless of pressure changes downstream on port 2.

Reverse flow from port 2 to port 1 is at the value of the fixed orifice and is nonpressure compensated.

Hardened and ground and honed working components. Cartridge construction for maximum mounting flexibility.

Performance Data Ratings and Specifications

Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F) Typical application pressure (all ports) 210 bar (3000 psi) Cartridge fatigue pressure (infinite life) 210 bar (3000 psi) Rated flow 38 L/min (10 USgpm) Temperature range –40° to 120°C (–40° to 248°F) Flow regulation accuracy 0,4–1,9 L/min (0.1–0.49 USgpm) ±20% 1,9–7,5 L/min (0.5–1.99 USgpm) ±15% 7,6–37,8 L/min (2.0–10.0 USgpm) ±10% Factory set maximum flow rate accuracy under standard test conditions and within the above ranges

Cavity Fluids Filtration Standard housing material Weight cartridge only Seal kit

H

C-10-2 All general purpose hydraulic fluids such as: MIL-H-5606, SAE 10, SAE 20 etc. Cleanliness code 18/16/13 Aluminum 0,22 kg (.48 lbs) 565803 (Buna-N), 566086 (Viton®)

Viton is a registered trademark of E.I. DuPont

2 1

Description

Typical Flow Regulation

This valves is a limited range adjustable, pressure compensated, screw-in flow regulator cartridge valve.

Cartridge only

70

35

100

140

175 210 40

A

9

30

6

B

20

3

10

0

Flow - L/min (21,8 cSt oil @ 49°C)

0 Flow - USgpm (105 SUS oil @ 120°F)

The flow adjustment is from the factory set maximum flow rate down to 50% of that factory set flow rate.

Pressure - bar

0 0

500

1000

1500

2000 2500 3000

Pressure - psi

A - 38,0 L/min (10.0 USgpm) B - 19,0 L/min (5.0 USgpm) Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-140.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

FR2-10 - Flow Regulator Limited range, adjustable pressure compensated 38 L/min (10 Usgpm) • 210 bar (3000 psi)

Model Code

FR 2 – 10



1 1

FR2 - Flow regulator

2

Size

10 - 10 Size

3

Seal material

Blank - Buna-N V- Viton®

4 C- F- I- K- S-

2

5

Function

Adjustment

(V) – 3

4

5

6

7

Port Size

6

Code

Port Size

Housing Number

0 3B 6T 2G 3G 6H 8H

Cartridge only 3/8" BSPP SAE 6 1/4" BSPP 3/8" BSPP SAE 6 SAE 8

Aluminium Light duty

Aluminium Fatigue rated

02–175462 566151 – – – –

– – 876702 876703 876700 876701

Factory set flow rate,

(Specify in USgpm) Range 0,38–22,7 L/min (0.1–10.0 USgpm)

7

Special features

00 – None (Only required if valve has special features, omitted if “00”) SS - 316 Stainless Steel external components

See section J for housing details.

Cap Factory-set Internal Knob Screw

Torque cartridge in aluminum housing to 47-54 Nm (35-40 ft lbs)

Dimensions

mm (inch) Cartridge Basic Code FR2-10 "S" Adjustment 4,8 (0.18) hex

* – *** – *.* – 00

Installation Drawing

H

"K" Adjustment Ø38,1 (1.5)

19.0 HEX (0.75) "F" Adjustment

"C" Adjustment 19,0 (0,75) hex

83.8 (3.30)

25.4 (1.00)

25.4 HEX (1.00)

"I" Adjustment

19.1 (0.75) 80,0 (3.15) 53,0 (2.09)

25,4 (1.00) hex

0.875" -14 Thd. 2

31,7 (1.25)

25,4 (1.00) hex

63.5 (2.50)

2

44.5 (1.75) 1

9.5 (0.37)

44.46 (1.750) 63.5 (2.50)

2 x 7.14 (0.281)

1

1 Ø15,82 (0.623)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-141.A

FR2-16 - Flow Regulator Limited range, adjustable pressure compensated 114 L/min (30 USgpm) • 210 bar (3000 psi)

2

1

Operation

Features

This valve maintains a constant flow from port 1 to port 2 based on the setting adjustment, regardless of pressure changes down stream on port 2. Reverse flow from port 2 to port 1 is at the value of the fixed orifice and is non-pressure compensated..­

Hardened and ground and honed working components. Cartridge construction for maximum mounting flexibility.

Performance Data

Sectional View

Ratings and Specifications

Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F) Typical application pressure (all ports) 210 bar (3000 psi) Cartridge fatigue pressure (infinite life) 210 bar (3000 psi) Rated flow 114 L/min (30 USgpm) Temperature range –40° to 120°C (–40° to 248°F) Flow regulation accuracy 1,9–10,9 L/min (0.5–2.9 USgpm) ±15% 11,4–114 L/min (3–30 USgpm) ±10% Factory set maximum flow rate accuracy under standard test conditions and within the above ranges

Cavity Fluids Filtration Standard housing material Weight cartridge only Seal kit

H

C-16-2 All general purpose hydraulic fluids such as: MIL-H-5606, SAE 10, SAE 20 etc. Cleanliness code 18/16/13 Aluminum 0,71 kg (1.57 lbs) 565810 (Buna-N) 889609 (Viton®)

Viton is a registered trademark of E.I. DuPont

2 1 Description

Typical Flow Regulation

This valves is a limited range adjustable, pressure compensated, screw-in flow regulator cartridge valve.

Cartridge only

70

35

100

140

175 210 40

A

9

30

6

B

20

3

10

0

Flow - L/min (21,8 cSt oil @ 49°C)

0 Flow - USgpm (105 SUS oil @ 120°F)

The flow adjustment is from the factory set maximum flow rate down to 50% of that factory set flow rate.

Pressure - bar

0 0

500

1000

1500

2000 2500 3000

Pressure - psi

A - 114 L/min (30.0 USgpm) B - 38 L/min (10.0 USgpm) C - 9,5 L/min (2.5 USgpm) Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-150.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

FR2-16 - Flow Regulator Limited range, adjustable pressure compensated 114 L/min (30 USgpm) • 210 bar (3000 psi)

Model Code

FR 2 – 16

1

1 Function

5

FR2 - Flow regulator

2

Size

16 - 16 Size

3

Seal material

Blank - Buna-N V- Viton®

4

Adjustment

(V) –

2

3

4

5

6

7 6

Port Size

Code

Port Size

Housing Number

0 6B 12T 4G 6G 10H 12H

Cartridge only 3/4" BSPP SAE 12 1/2" BSPP 3/4" BSPP SAE 10 SAE 12

Aluminium Light duty

Aluminium Fatigue rated

02–175463 566149 – – – –

– – 876716 876718 876717 876713

C - Cap K - Knob S - Screw Y - Knob (Stainless)

See section J for housing details.

Dimensions

Torque cartridge in aluminum housing to 108-122 Nm (80-90 ft lbs)

mm (inch)

* – *** – *.* – 00

Cartridge Basic Code FR2-16

Factory Set Flow Rate,

(Specify in USgpm) Range 1,9–114 L/min (0.5–30 USgpm)

7

Special features

00 – None (Only required if valve has special features, omitted if “00”) SS - 316 Stainless Steel external components

H

Installation Drawing

"S" Adjustment 9,6 (0.37) hex "C" Adjustment 19,1 (0.75) hex

"K" Adjustment Ø50,8 (2.00)

104.0 (4.09)

31.8 (1.25) 38.1 HEX (1.50)

107,2 (4.22)

104,0 (4.09)

2

63.5 88.9 (2.50) (3.50)

38,1 (1.50) hex

1 10.3 (0.41)

1.312 " -12 Thd. 2

44,5 (1.75)

68.28 88.29 (2.688) (3.50)

28.4 (1.12)

2 x 8.74 (0.344)

1

1 Ø28,55 (1.124) Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-151.A

2CFRC60 - Flow Regulator Restrictive, pressure compensated with reverse check 4-60 L/min (1 to 16 USgpm) • 350 bar (5000 psi)

Operation

2

1

Sectional View

Features

Flow into the inlet of the valve passes through the adjustable orifice and out of the regulated port. The pressure drop across the orifice is sensed on the regulating sleeve and produces a force which, at the required

flow rate, overcomes the spring force. The resultant movement of the sleeve regulates the flow by closing the radial valve ports. The inbuilt check allows free return of flow (2 to 1).

Cartridge construction gives versatility of application. A valve may be fitted into a line body, a custom designed Hydraulic Integrated Circuit or directly into a cylinder or other actuator. Leakproof adjust screw gives easy, accurate adjustment to required flow setting. Hardened and ground working parts give accurate flow control and long working life.

Performance Data Ratings and Specifications

Reg (2)

Viton is a registered trademark of E.I. DuPont

Description

Pressure Drop Curves

This is a two-port, restrictive flow regulator with a built in free flow check valve. Typical uses include the control of actuator speed by regulating the flow into or out of the actuator (meter-in or meter-out).

Cartridge only

The flow (and actuator speed) will be largely independent of the load and the pressure conditions. If used to restrict flow from a fixed supply, for example a standard gear or piston pump, the valve will pass the required flow and any surplus flow will normally pass over the system relief valve.

25

0

70

Load pressure - bar 140 210 280

350

100

20

80

15

60

10

40

5

20

0

0 0

1000

2000 3000 4000 5000 Load pressure - psi

Regulated flow - litres/min

Inlet (1)

Regulated flow - US gpm

H

Figures based on oil temperature of 40˚ C and of 32 cSt (150 SUS) Rated Flow 4 to 60 liters/min (1 to 16 USgpm) Maximum pressure 350 bar (5000 psi) Cartridge material All working parts hardened & ground steel. Zinc plated body Standard housing material Standard aluminum (up to 210 bar*) Add suffix “377” for steel option Mounting position Unrestricted Cavity Number A7447 (See Section M) Torque cartridge into cavity 75 Nm (55 ft lbs) Weight 2CFRC60: 0,29 kg (0.64 lbs) 2CFRC65: 0,75 kg (1.65 lbs) Seal kit number SK578 (Nitrile) SK578V (Viton®) Recommended Filtration Level BS5540/4 Class 18/13 (25 micron nominal) Operating temperature –30° to +90°C (–22° to +194°F) Nominal range 5 to 500 cSt

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-160.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

2CFRC60 - Flow Regulator Restrictive, pressure compensated with reverse check 4-60 L/min (1 to 16 USgpm) • 350 bar (5000 psi)

2CFRC** –

Model Code

P

1 1

2

Basic code

2CFRC60 - Cartridge only 2CFRC65 - Cartridge & body

4W – 4

2

Adjustment Means

3 3

P - Leakproof screw adjustment R - Handknob adjustment (See page H-6 for dimensions)



S

4

5

Port Size - Bodied Valves Only

4W - 1/2" BSP 8T - 1/2" SAE

4

5

Seals

S - Nitrile (for use with most industrial hydraulic oils SV - Viton (for high temperature & most special fluid applications)

Adjustable Flow Range

4 - 4-40 L/min. Standard setting 30 L/min 6 - 6-60 L/min. Standard setting 40 L/min

Dimensions

Note: For applications above 210 bar (3000 psi) please consult our technical department or use the steel body option

mm (inch)

Cartridge Only Basic Code 2CFRC60

Hex socket adjust 4.0 A/F

Complete Valve Basic Code 2CFRC65

H

49.5 (1.95) max

124.5 (4.90) max

32.0 A/F

2

1

46.0 (1.81)

57.0 (2.24)

75.0 (2.95)

19.0 (0.75)

25.5 (1.00)

M27 x 2.0-6g

28.5 (1.12)

9.0 (0.35)

17.0 A/F

53.0 (2.09) 63.5 (2.50)

38.1 (1.50)

2 holes Ø11.0 (0.43) thro’

Reg (2)

Inlet (1) Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-161.A

FAR1-10 - Flow Regulator Fully adjustable, pressure compensated with free reverse flow 1-38 L/min (0.25-10 USgpm) • 310 bar (4500 psi)

Operation

2

1

Sectional View

Features

Flow into the inlet of the valve passes through the adjustable orifice and out of the regulated port. The pressure drop across the orifice is sensed on the regulating sleeve and produces a force which, at the

required flow rate, overcomes the spring force. The resultant movement of the sleeve regulates the flow by closing the radial valve ports. The inbuilt check allows free return of flow (2 to 1).

Cartridge construction gives versatility of application. A valve may be fitted into a line body, a custom designed Hydraulic Integrated Circuit or directly into a cylinder or other actuator. Leakproof adjust screw gives easy, accurate adjustment to required flow setting. Hardened and ground working parts give accurate flow control and long working life.

Performance Data Ratings and Specifications

Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F) Typical application pressure (all ports) 5–350 bar (75–5000 psi) steel housing Min. pressure differential across valve 14 bar (200 psi) Cartridge fatigue pressure (infinite life) 310 bar (4500 psi) Rated flow 1–38 L/min (0.25–10 USgpm) Temperature range 40° to 120°C (–40° to 248°F) Flow regulation accuracy 4–38 L/min (1–10 USgpm) ±10% 1–4 L/min (0.25–1 USgpm) ±20% Factory set maximum flow rate accuracy under standard test conditions and within the above ranges

Viton is a registered trademark of E.I. DuPont

Description

Typical Flow Regulation

This is a two-port, restrictive flow regulator with a built in free flow check valve. Typical uses include the control of actuator speed by regulating the flow into or out of the actuator (meter-in or meter-out).

Cartridge only

8

16

24

32

40

200 Pressure drop - psi

The flow (and actuator speed) will be largely independent of the load and the pressure conditions. If used to restrict flow from a fixed supply, for example a standard gear or piston pump, the valve will pass the required flow and any surplus flow will normally pass over the system relief valve.

TYPICAL FLOW REGULATION Pressure differential across valve in bar 70 140 210 280

PRESSURE DROP FOR REVERSE FLOW Flow - L/min (21,8 cSt oil @ 49ºC)

12

150

8

100

4

50 0

2

4

6

8

10

12

Flow - USgpm (105 SUS oil @ 120°F)

12

350 40

10 8

32

6

24

4

16

2

8 0

1000

2000

3000

4000

Flow -L/min (21,8 cSt oil @ 49°C)

1

Flow - USgpm (105 SUS oil @ 120°F)

2

1.7 bar (25 psi) 0.4 L/min (24.4 in3/min) C-10-2 All general purpose hydraulic fluids such as: MIL-H-5606, SAE 10, SAE 20 etc. Cleanliness code 18/16/13 Aluminum or Steel “S” 0,02 kg (0.44 lbs) “K” 0,23 kg (0.51 lbs) “H” 0,26 kg (0.59 lbs) 565803 (Buna-N), 566086 (Viton®)

Pressure drop - bar

H

Reverse check crack pressure Leakage at shutoff position Cavity Fluids Filtration Standard housing material Weight cartridge only Seal kit

5000

Pressure differential across valve in psi

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-170.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

FAR1-10 - Flow Regulator Fully adjustable, pressure compensated with free reverse flow 1-38 L/min (0.25-10 USgpm) • 310 bar (4500 psi)

Model Code

FAR1 – 10



1 1

4

Function

FAR1 - Flow adjustable, pressure compensated flow regulator with reverse flow check

2

3

6

Seal Material

Blank - Buna-N V- Viton®

2

3

4 5

Adjustment Means

H - Calibrated handknob with locknut K - Handknob with locknut S - Screw with locknut

Size

10 - 10 Size

(V) – * –

*

– ** – *.* – 00

5

6

7

Valve Housing Material

7

mm (inch)

Port Size

8

Code

Port Size

Housing Number

0 3B 2G 3G 6H 8H 6T 8T

Cartridge only 3/8" BSPP 1/4" BSPP 3/8" BSPP SAE 6 SAE 8 SAE 6 SAE 8

Aluminium Light duty

Aluminium Fatigue rated

Steel Fatigue rated

02–175462 – – – – 566151 –

– 876702 876703 876700 876701 – –

– 02-175102 02-175103 – – 02-175100 02-175101

Torque cartridge in housing A - 47-54 Nm (35-40 ft lbs) S - 68-75 Nm (50-55 ft lbs) “K” adjustment kit – 565585

Cartridge Basic Code FAR1-10

Note: To reset scale and knob to an optimum viewing position: 1. Loosen the set screw 2. Rotate zero point on scale to a desired orientation. 3. Align mark on knob with zero on scale. 4. Tighten the set screw firmly.

Factory Set Flow Rate

Blank - Normal factory setting at 5 USgpm User requested setting within .25–10 US gpm (1-–38 L/min.)

Omit for cartridge only A - Aluminum S - Steel

Special features

00 – None (Only required if valve has special features, omitted if “00”)

WARNING Aluminum housings can be used for pressures up to 210 bar (3000 psi). Steel housings must be used for operating pressures above 210 bar (3000 psi).



See section J for housing details. Dimensions

8

Note: To change the setting: 1. Loosen the set screw 2. Loosen jamnut while holding the knob steady, or move the knob along the axis slightly. 3. Turn adjusting screw (jam nut and knob will turn at the same time).

4. At the new adjusting screw position, tighten jamnut firmly while holding the knob steady, or move the knob along the axis slightly. 5. Tighten the set screw firmly.

Installation Drawing (Steel)

"K" adjustment

"S" adjustment 4,75 (0.19) hex

Ø38,1 (1.50)

61,1 (2.40) max.

56,9 (2.24)

25,4 (1.00) hex

38,1 (1.50) 30,5 (1.20)

"H" adjustment

58.7/62.7 Max (2.31)/(2.47 Max)

2

72,4 (2.85)

63.5 (2.50)

50.8 (2.00)

19 (0.75) 1

31,8 2 (1.25)

0.875"–14 Thd. 1

76,5 (3.01) max.

9.5 (0.37)

44.5 (1.75)

2 X Ø7.14 (0.281)

63.5 (2.50)

22.2 (0.87) 44.45 (1.750)

Ø15,8 (0.62) Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-171.A

H

FAR1-12 - Flow Regulator Fully adjustable, pressure compensated with free reverse flow 1.5-94.5 L/min (0.4-25 USgpm) • 310 bar (4500 psi)

Operation

2

1

Sectional View

Features

Flow into the inlet of the valve passes through the adjustable orifice and out of the regulated port. The pressure drop across the orifice is sensed on the regulating sleeve and produces a force which, at the required

flow rate, overcomes the spring force. The resultant movement of the sleeve regulates the flow by closing the radial valve ports.

Cartridge construction gives versatility of application. A valve may be fitted into a line body, a custom designed Hydraulic Integrated Circuit or directly into a cylinder or other actuator. Leakproof adjust screw gives easy, accurate adjustment to required flow setting. Hardened and ground working parts give accurate flow control and long working life.

The inbuilt check allows free return of flow (2 to 1).

Performance Data Ratings and Specifications

Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F) Typical application pressure (all ports) 350 bar (5000 psi) Min. pressure differential across valve 15,9 bar (230 psi) Max. pressure differential across valve 329 bar (4770 psi) Cartridge fatigue pressure (infinite life) 310 bar (4500 psi) Rated flow 1,5–94,5 L/min (.4–25 USgpm) Temperature range 40° to 120°C (–40° to 248°F) Flow regulation accuracy 1,5–3,8 L/min (.4–1.0 USgpm) ±20% @5000 psi above 3,8–68,1 L/min (above 1–18 USgpm) ±10% @3000 psi above 68,1–94,6 L/min (above 18–25 USgpm) ±15% @3000 psi 3,8–56,8 L/min (1–15 USgpm) ±10% @5000 psi above 56,8–89,1 L/min (above 15–23 USgpm) ±15% @5000 psi Factory set maximum flow rate accuracy under standard test conditions and within the above ranges

2

H

1

Reverse check crack pressure Leakage at shutoff position Cavity Fluids Filtration Standard housing material Weight cartridge only Seal kit

1.7 bar (25 psi) 0,5 L/min (30 in3/min) C–12–2 & C–12–2U All general purpose hydraulic fluids such as: MIL-H-5606, SAE 10, SAE 20 etc. Cleanliness code 18/16/13 Aluminum or Steel “S” 0,43 kg (0.95 lbs) 02–181304 (Buna-N) 02–181305 (Viton®)

Viton is a registered trademark of E.I. DuPont

Typical Flow Regulation

This is a two-port, restrictive flow regulator with a built in free flow check valve. Typical uses include the control of actuator speed by regulating the flow into or out of the actuator (meter-in or meter-out).

Cartridge only

45

60

75

90

70 12

150

8

100

4

50 0

4 8 12 16 20 Flow - USgpm (105 SUS oil @ 120°F)

24

Flow - USgpm (105 SUS oil @ 120°F)

30

200

Pressure drop - bar

15 Pressure drop - psi

The flow (and actuator speed) will be largely independent of the load and the pressure conditions. If used to restrict flow from a fixed supply, for example a standard gear or piston pump, the valve will pass the required flow and any surplus flow will normally pass over the system relief valve.

TYPICAL FLOW REGULATION Pressure differential across valve in bar

PRESSURE DROP FOR REVERSE FLOW Flow - L/min (21,8 cSt oil @ 49 °C) 24

140

210

280

350 90 75

20 16

60

12

45

8

30

4

15

0

Flow - L/min (21,8 cSt oil @ 49°C)

Description

1000 2000 3000 4000 5000 Pressure differential across valve in psi

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-180.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

FAR1-12 - Flow Regulator Fully adjustable, pressure compensated with free reverse flow 1.5-94.5 L/min (0.4-25 USgpm) • 310 bar (4500 psi)

Model Code

FAR1 – 12



1 1

Function

5

FAR1 - Flow adjustable, pressure compensated flow regulator with reverse flow check

2

Seal Material

Blank - Buna-N V- Viton®

4

Adjustment

H - Calibrated handknob with locknut K - Handknob with locknut S - Screw with locknut

Dimensions

mm (inch) Torque cartridge in housing A - 81-93 Nm (60-70 ft lbs) S - 102-115 Nm (75-85 ft lbs) “K” adjustment kit – 565585 Cartridge Basic Code FAR1-12

"K" adjustment

"S" adjustment 4,75 (0.19) hex

6

*

4

– ** – *.* – 00

5

6

7

8

Valve Housing Material S - Steel

Port Size Port Size

See section J for housing details.

Housing Number

C-12-2U Aluminium Fatigue rated

C-12-2 Aluminium Fatigue rated

C-12-2U Steel Fatigue rated

C-12-2 Steel Fatigue rated

02–160641 02–160645 02–161116 02–161115

02-160640 02-160644 02-161118 02-161117

02-169817 02-169790 02-172512 02-162922

02-169744 02-169782 02-172062 02-169665

See section J for housing details.

7

Factory Set Flow Rate

8

Special Features

Blank - Normal factory setting at 10 USgpm User requested setting Within 0.4–25 US gpm (1,5-–94,5 L/min.) up to 210 bar (3000 psi) Within 0.4-23 USgpm (1,5-87,1 L/min.) up to 350bar (5000 psi)

00 – None

Note: To reset scale and knob to an optimum viewing position: 1. Loosen the set screw 2. Rotate zero point on scale to a desired orientation. 3. Align mark on knob with zero on scale. 4. Tighten the set screw firmly.

4. At the new adjusting screw position, tighten jamnut firmly while holding the knob steady, or move the knob along the axis slightly. 5. Tighten the set screw firmly.

67,2 (2.65)

Note: To change the setting: 1. Loosen the set screw 2. Loosen jamnut while holding the knob steady, or move the knob along the axis slightly. 3. Turn adjusting screw (jam nut and knob will turn at the same time).

31.8 HEX (1.25)

25.4 (1.00)

12.7 (0.50)

12.7 (0.50)

82,6 (3.25)

(Only required if valve has special features, omitted if “00”)

Installation Drawing (Steel)

38,1 (1.50) 30,5 (1.20)

"H" adjustment Ø38,1 (1.50)

73,1 (2.88) max.

31,7 (1.25) hex

3

0 Cartridge only 10T(U) SAE 10 12T(U) SAE 12 4G(U) 1/2" BSPP 6G(U) 3/4" BSPP

12 - 12 Size

3

2

Omit for cartridge only A - Aluminum

Code

Size

(V) – * –

28.7 (1.13)

2 63.5 (2.50)

88.9 (3.50) 1

44,7 2 (1.76)

1. 06"–12 Thd. 1

Ø23,7 (0.94)

63.50 (2.500) 88.9 (3.50)

88,4 (3.48) max.

1 2 x 010.31 (0.406)

WARNING Aluminum housings can be used for pressures up to 210 bar (3000 psi). Steel housings must be used for operating pressures above 210 bar (3000 psi).



Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-181.A

H

FAR1-16 - Flow Regulator Fully adjustable, pressure compensated with free reverse flow 3.8-114 L/min (1-30 USgpm) • 310 bar (4500 psi)

Operation

2

1

Sectional View

Features

Flow into the inlet of the valve passes through the adjustable orifice and out of the regulated port. The pressure drop across the orifice is sensed on the regulating sleeve and produces a force which, at the required flow rate, overcomes

the spring force. The resultant movement of the sleeve regulates the flow by closing the radial valve ports. The inbuilt check allows free return of flow (2 to 1).

Cartridge construction gives versatility of application. A valve may be fitted into a line body, a custom designed Hydraulic Integrated Circuit or directly into a cylinder or other actuator. Leakproof adjust screw gives easy, accurate adjustment to required flow setting. Hardened and ground working parts give accurate flow control and long working life.

Performance Data Ratings and Specifications

Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F) Typical application pressure (all ports) 350 bar (5000 psi) Min. pressure differential across valve 17 bar (250 psi) Max. pressure differential across valve 328 bar (4750 psi) Cartridge fatigue pressure (infinite life) 310 bar (4500 psi) Rated flow 3,8–113,6 L/min (1–30 USgpm) Temperature range 40° to 120°C (–40° to 248°F) Flow regulation accuracy 3,8–15,1 L/min (1.0–4.0 USgpm) ±30% @5000 psi above 15,1–30,3 L/min (above 4.0–8.0 USgpm) ±20% @5000 psi above 30,3–113,6 L/min (above 8.0–30.0 USgpm) ±10% @5000 psi Factory set maximum flow rate accuracy under standard test conditions and within the above ranges

H

2

1

Reverse check crack pressure Leakage at shutoff position Cavity Fluids Filtration Standard housing material Weight cartridge only Seal kit

1.7 bar (25 psi) 0,55 L/min (33.5 in3/min) C–16–2 All general purpose hydraulic fluids such as: MIL-H-5606, SAE 10, SAE 20 etc. Cleanliness code 18/16/13 Aluminum or steel “S” 0,67 kg (1.48 lbs) “K” 0,70 kg (1.55 lbs) “H” 0,74 kg (1.62 lbs) 565810 (Buna-N) 889609 (Viton®)

Viton is a registered trademark of E.I. DuPont

Cartridge only

200

20

40

60

80

100

120 12

150 8

100

4

50 0

6

12

18

24

30

36

Flow - USgpm (105 SUS oil @ 120°F)

36

TYPICAL FLOW REGULATION Pressure differential across valve in bar 100 240 300 350 120 100 80

30 24 18 12

60 40

6

20 1000

2000

3000

4000

Flow - L/min (21,8 cSt oil @ 49°C)

PRESSURE DROP FOR REVERSE FLOW Flow - L/min (21,8 cSt oil @ 49°C) Flow - USgpm (105 SUS oil @ 120°F)

The flow (and actuator speed) will be largely independent of the load and the pressure conditions. If used to restrict flow from a fixed supply, for example a standard gear or piston pump, the valve will pass the required flow and any surplus flow will normally pass over the system relief valve.

Typical Flow Regulation

Pressure drop - bar

This is a two-port, restrictive flow regulator with a built in free flow check valve. Typical uses include the control of actuator speed by regulating the flow into or out of the actuator (meter-in or meter-out).

Pressure drop - psi

Description

5000

Pressure differential across valve in psi

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-190.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

FAR1-16 - Flow Regulator Fully adjustable, pressure compensated with free reverse flow 3.8-114 L/min (1-30 USgpm) • 310 bar (4500 psi)

Model Code

FAR1 – 16

1

Function

FAR1 - Flow adjustable, pressure compensated flow regulator with reverse flow check

2

16 - 16 Size

3

1

2

4

Adjustment

Seal material

Blank - Buna-N V- Viton®

3

H - Calibrated handknob with locknut K - Handknob with locknut S - Screw with locknut

6

Size

(V) – * –

*

– ** – *.* – 00

4

5

6

5

Valve Housing Material

7 7

Omit for cartridge only A - Aluminum S - Steel

Port Size

Housing Number

4G 6B 6G 10T 10H 12T 12H

1/2" BSPP 3/4" BSPP 3/4" BSPP SAE 10 SAE 10 SAE 12 SAE 12

Aluminium Light duty – 02-175463 – – – 566149 –

Aluminium Fatigue rated 876716 – 876718 – 876717 – 566113

Factory Set Flow Rate

Blank - Normal factory setting at 15 USgpm User requested setting Within 1-30 USgpm (3,8-113,6 L/min.)

Port Size

Code

8

Steel Fatigue rated 02-175106 – 02-175107 – 02-175104 – 02-175105

8 Special features 00 – None (Only required if valve has special features, omitted if “00”)

See section J for housing details. Dimensions

mm (inch) Torque cartridge in housing A - 108–122 Nm (80–90 ft lbs) S - 136–149 Nm (100–110 ft lbs)

Note: To reset scale and knob to an optimum viewing position: 1. Loosen the set screw 2. Rotate zero point on scale to a desired orientation. 3. Align mark on knob with zero on scale. 4. Tighten the set screw firmly.

Note: To change the setting: 1. Loosen the set screw 2. Loosen jamnut while holding the knob steady, or move the knob along the axis slightly. 3. Turn adjusting screw (jam nut and knob will turn at the same time).

4. At the new adjusting screw position, tighten jamnut firmly while holding the knob steady, or move the knob along the axis slightly. 5. Tighten the set screw firmly. WARNING Aluminum housings can be used for pressures up to 210 bar (3000 psi). Steel housings must be used for operating pressures above 210 bar (3000 psi).



Cartridge Basic Code FAR1-16

"H" Adjustment "K" Adjustment Ø38,1 82,1 (3.40) max. (1.50) 79,1 (3.11)

"S" Adjustment 4,75 (0.19) hex

30,5 (1.20)

38,1 (1.50)

Installation Drawing (Steel)

79.1 (3.11)

94,5 (3.72)

38,1 (1.50) hex 79,1 (3.11)

2

63.5 (2.50)

2X Ø10.31 (0.406)

46,4 (1.83)

1.312"–12 T hd. 28,5 (1.12)

1

101,9 (4.01) max. 12.7 (0.50)

25.4 (1.00)

76.2 (3.00)

63.5 (0.25) 88.9 (3.50)

25.4 (1.00)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-191.A

H

PFR5-8 - Flow Regulator Fixed, priority type, pressure compensated Up to 10 L/min (2.5 USgpm) • 280 bar (4000 psi)

Operation 3

1

2

Sectional View

Features

Inlet flow passes through the fixed orifice and the radial holes in the spool/sleeve assembly then out of the regulated port. The pressure drop across the orifice is sensed at each end of the spool, producing a force which, at the required flow rate, overcomes the spring

force. The resultant movement of the spool regulates the flow by opening the radial valve ports to the bypass port and closing the regulated flow ports. The valve will pass flow in the return direction but this is restricted by the flow path through the control orifice.

Cartridge construction gives versatility of application. A valve may be fitted into a line body, a custom designed Hydraulic Integrated Circuit or directly into a cylinder or other actuator. Leakproof adjust screw gives easy, accurate adjustment to required flow setting. Hardened and ground working parts give accurate flow control and long working life.

Performance Data Ratings and Specifications

3

Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F) Typical application pressure (all ports) 350 bar (5000 psi) in steel housing Cartridge fatigue pressure (infinite life) 280 bar (4000 psi) Rated flow maximum inlet flow 15,1 L/min (4 USgpm) maximum regulated flow 10 L/min (2.5 USgpm) Temperature range -40° to 120°C (-40° to 248°F) 3 3 Internal leakage 82 cm /min. @ 350 bar (3000 psi) 5 in /min @ 5000 psi) Flow regulation accuracy 0,4–1,9 L/min (0.1–0.49 USgpm) ±20% @ 210 bar (3000 psi) 0,4–1,9 L/min (0.1–0.49 USgpm) ±40% @ 350 bar (5000 psi) 1,9–5,7 L/min (0.5–1.49 USgpm) ±15% @ 350 bar (5000 psi) 5,7–10 L/min (1.5–2.5 USgpm) ±10% @ 350 bar (5000 psi) Factory set maximum flow rate accuracy under standard test conditions and within the above ranges

2

H

1

Cavity Fluids Filtration Standard housing material Weight cartridge only Seal kit Viton is a registered trademark of E.I. DuPont

Description

Typical Flow Regulation

These valves are priority flow regulators. The flow (and actuator speed) will be largely independent of the load and the pressure conditions.

Cartridge only

The valve inlet pressure will be approximately 7 bar (100 psi) more than the regulated or bypass pressure, whichever is higher.

350 280 210 3.0

140

Pressure - bar 70 0 70

140

210

280 350

12

2.5

10

2.0

8

1.5

6

1.0

4

0.5

2

Flow - L/min (21,8 cSt oil @ 49°C)

Flow - USgpm (105 SUS oil @ 120°F)

If used to regulate flow from a fixed supply, for example a standard gear or piston pump, the valve will pass the required flow and any surplus flow will be diverted to the bypass port. The bypass flow may be used for a secondary circuit whether the secondary pressure requirement is higher or lower than the regulated pressure.

C–8–3 All general purpose hydraulic fluids such as MIL-H-5606, SAE 10, SAE 20 etc. Cleanliness code 18/16/13 Aluminum or steel 0,07 kg (0.15 lbs) 02–173427 (Buna-N) 02–173434 (Viton®)

0 5000 4000 3000 2000 1000

0

1000 2000 3000 4000 5000

0

Bypass pressure Priority pressure higher than priority higher than bypass Pressure - psi

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-200.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

PFR5-8 - Flow Regulator Fixed, priority type, pressure compensated Up to 10 L/min (2.5 USgpm) • 280 bar (4000 psi)

(V) – F – (*) – ** – *.* – **

PFR5 – 8

Model Code

1 1 Function

2

3

4

5

6

7

8

6 Port Size

PFR5 - Priority flow regulator

Code

7 Factory Set Flow Rate

Port Size

Housing Number

0 Cartridge only 4T SAE 4 6T SAE 6 2G 1/4" BSPP 3G 3/8" BSPP

2 Size 8 - 8 size

3 Seals Blank - Buna-N V - Viton®

(Specify in USgpm) Range 0,4–9,5 L/min (0.1–2.5 USgpm)

Aluminium Fatigue Rated

Steel Fatigue Rated

02–160741 02–160742 02–160739 02–160740

02-160745 02-160746 02-160743 02-160744

8 Special Features 00 – None (Only required if valve has special features, omitted if “00”) SS - 316 Stainless Steel external components

See section J for housing details.

4 Adjustment F - Fixed orifice

5 Valve Housing Material Omit for cartridge only S - Steel A - Aluminum

Torque cartridge in steel or aluminum housing to 34–41 Nm (25–30 ft lbs).

Dimensions

mm (inch)

H

Cartridge Basic Code PFR5-8

Installation Drawing (Steel) 19 x 1 9.1 (0.75) (0.36)

8,5 (0.33)

3

22,1 (.870) hex

54.0 15.5 (2.12) (0.61) 66.7 (2.63)

0.750"–16 Thd.

1

3

40,6 (1.60)

2

3.4 (0.13)

56.9 (2.24) 63.5 (2.50)

29.7 (1.17)

2 x 7.14 (0.281)

2

1

Ø14,2 (0.559) Ø15,8 (0.622)

WARNING Aluminum housings can be used for pressures up to 210 bar (3000 psi). Steel housings must be used for operating pressures above 210 bar (3000 psi).



Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-201.A

PFR5-10 - Flow Regulator Fixed, priority type, pressure compensated Up to 23 L/min (6 USgpm) • 280 bar (4000 psi)

Features

Operation 3

1

2

Sectional View

force. The resultant movement of the spool regulates the flow by opening the radial valve ports to the bypass port and closing the regulated flow ports.

Inlet flow passes through the fixed orifice and the radial holes in the spool/sleeve assembly then out of the regulated port. The pressure drop across the orifice is sensed at each end of the spool, producing a force which, at the required flow rate, overcomes the spring

The valve will pass flow in the return direction but this is restricted by the flow path through the control orifice.

Performance Data

Cartridge construction gives versatility of application. A valve may be fitted into a line body, a custom designed Hydraulic Integrated Circuit or directly into a cylinder or other actuator. Leakproof adjust screw gives easy, accurate adjustment to required flow setting. Hardened and ground working parts give accurate flow control and long working life.

Ratings and Specifications

3

2

1

Factory set maximum flow rate accuracy under standard test conditions and within the above ranges

Cavity Fluids Filtration Standard housing material Weight cartridge only Seal kit

C–10–3 All general purpose hydraulic fluids such as MIL-H-5606, SAE 10, SAE 20 etc. Cleanliness code 18/16/13 Aluminum or steel 0,13 kg (0.28 lbs) 565804 (Buna-N) 889599 (Viton®)

Viton is a registered trademark of E.I. DuPont

Description

Typical Flow Regulation

These valves are priority flow regulators. The flow (and actuator speed) will be largely independent of the load and the pressure conditions.

Cartridge only

The valve inlet pressure will be approximately 7 bar (100 psi) more than the regulated or bypass pressure, whichever is higher.

Flow - USgpm (105 SUS oil @ 120°F)

If used to regulate flow from a fixed supply, for example a standard gear or piston pump, the valve will pass the required flow and any surplus flow will be diverted to the bypass port. The bypass flow may be used for a secondary circuit whether the secondary pressure requirement is higher or lower than the regulated pressure.

350 280 210

140

Pressure - bar 70 0 70

140

210

280 350

6.0

24

5.0

20

4.0

16

3.0

12

2.0

8

1.0

4

0 5000 4000 3000 2000 1000 Bypass pressure higher than priority

0

Flow - L/min (21,8 cSt oil @ 49°C)

H

Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F) Typical application pressure (all ports) 350 bar (5000 psi) Cartridge fatigue pressure (infinite life) 280 bar (4000 psi) Rated flow Maximum inlet flow 60 L/min (15 USgpm) Maximum regulated flow 23 L/min (6 USgpm) Temperature range -40° to 120°C (-40° to 248°F) 3 3 Internal leakage 82 cm /min @ 350 bar (3000 psi) 5 in /min @ 5000 psi) Flow regulation accuracy 0,4–1,9 L/min (0.1–0.49 USgpm) ±20% @ 210 bar (3000 psi) 0,4–1,9 L/min (0.1–0.49 USgpm) ±40% @ 350 bar (5000 psi) 1,9–5,7 L/min (0.5–1.49 USgpm) ±15% @ 350 bar (5000 psi) 5,7–22,7 L/min (1.5–6 USgpm) ±10% @ 350 bar (5000 psi)

0 1000 2000 3000 4000 5000

Pressure - psi

Priority pressure higher than bypass

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-210.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

PFR5-10 - Flow Regulator Fixed, priority type, pressure compensated Up to 23 L/min (6 USgpm) • 280 bar (4000 psi)

PFR5 – 10

Model Code

1 1 Function

2

(V) – F – * – ** – *.* – 00 3

4

5

6

7

8 7 Factory Set Flow Rate

6 Port Size

PFR5 - Priority flow regulator

Code

Port Size

Housing Number

0 Cartridge only 2G 1/4" BSPP 3B 3/8" BSPP 3G 3/8" BSPP 6T SAE 6 6H SAE 6 8H SAE 8 8T SAE 8

2 Size 10 - 10 size

3 Seals Blank - Buna-N V - Viton®

4 Adjustment F - Fixed orifice

5 Valve Housing Material

(Specify in USgpm) Range 0,38-22,7 L/min (0.1-6.0 USgpm)

Aluminium Light Duty

Aluminum Fatigue Rated

Steel

– 02–173358 – 566162 – – –

876705 – 876714 – 876704 876711 02-175125

02-175127 – 02-175128 02-175124 – – –

8 Special Features 00 – None (Only required if valve has special features, omitted if “00”)

See section J for housing details.

Omit for cartridge only S - Steel A - Aluminum

Torque cartridge in housing A - 47-54 Nm (35-40 ft lbs) B - 68-75 Nm (50-55 ft lbs)

Dimensions

mm (inch)

Note: For applications above 210 bar (3000 psi) please consult our technical department or use the steel body option.

H

Installation Drawing (Steel)

Cartridge Basic Code PFR5-10

25,4 (1.0) hex

20,8 (0.82)

21.6 (0.85)

35.1 (1.38)

3 2

2X Ø7.14 (0.28)

0.875-14 Thd. 46,0 (1.81)

3

22.4 (0.88)

9.7 (0.38)

1

63.5 (2.50) 76.2 (3.00)

57.02 (2.245) 76.2 (3.00)

19.1 (0.75)

22.4 (0.88)

2

1

Ø15,82 (0.623) Ø17,42 (0.686)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-211.A

PFR15-10 - Flow Regulator Fixed, priority type, pressure compensated Up to 38 L/min (10 USgpm) • 350 bar (5000 psi)

Operation 3

1

2

Sectional View

Features

Inlet flow passes through the fixed orifice and the radial holes in the spool/sleeve assembly then out of the regulated port. The pressure drop across the orifice is sensed at each end of the spool, producing a force which, at the required flow rate, overcomes the spring

force. The resultant movement of the spool regulates the flow by opening the radial valve ports to the bypass port and closing the regulated flow ports. The valve will pass flow in the return direction but this is restricted by the flow path through the control orifice.

Performance Data

Cartridge construction gives versatility of application. A valve may be fitted into a line body, a custom designed Hydraulic Integrated Circuit or directly into a cylinder or other actuator. Leakproof adjust screw gives easy, accurate adjustment to required flow setting. Hardened and ground working parts give accurate flow control and long working life.

Ratings and Specifications

3

2

H

Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49° C (120° F) Typical Application pressure (all ports) 350 bar (5000 psi) Cartridge fatigue pressure (infinite life) 350 bar (5000 psi) Rated flow Maximum inlet flow 64 L/min (17 USgpm) Maximum regulated flow 38 L/min (10 USgpm) Flow regulation accuracy 0,4-1,9 L/min (0.1-0.49 USgpm) ±20% @ 210 bar (3000 psi) 0,4-1,9 L/min (0.1-0.49 USgpm) ±40% @ 350 bar (5000 psi) 1,9-5,7 L/min (0.5-1.49 USgpm) ±15% @ 350 bar (5000 psi) 5,7-22,7 L/min (1.5-6 USgpm) ±10% @ 350 bar (5000 psi) Factory set maximum priority flow rate accuracy under standard test conditions and within the above ranges Temperature range -40° to 120°C (-40° to 248°F) Cavity C-10-3 Fluids All general purpose hydraulic fluids such as MIL-H-5606, SAE 10, SAE 20, etc. Filtration 18/16/13 Standard housing materials Aluminum or Steel Weight cartridge only 0,13 kg (0.28 lb.) Seal kit 565804 (Buna-N), 889599 (Viton®) Viton is a registered trademark of E.I. DuPont

1 Description

Typical Flow Regulation

The valve inlet pressure will be approximately 7 bar (100 psi) more than the regulated or bypass pressure, whichever is higher.

0 12

140

210

275

A

10

6 4 2 0

355 40

B

8

0

70

30

A

20

B

10 1000

2000

3000

4000

Priority flow rate - L/min (21,8 cSt oil @ 490 C)

If used to regulate flow from a fixed supply, for example a standard gear or piston pump, the valve will pass the required flow and any surplus flow will be diverted to the bypass port. The bypass flow may be used for a secondary circuit whether the secondary pressure requirement is higher or lower than the regulated pressure.

Back pressure - bar

Priority flow rate - USgpm (105 SUS oil @ 1200 F)

These valves are priority flow regulators. The flow (and actuator speed) will be largely independent of the load and the pressure conditions.

0 5000

Back pressure - psi

A - Port 3, priority (regulated outlet) pressurized. B - Port 2, (bypass outlet) pressurized.

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-220.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

PFR15-10 - Flow Regulator Fixed, priority type, pressure compensated Up to 38 L/min (10 USgpm) • 350 bar (5000 psi)

Model Code

PFR15 – 10

1 Function PFR15 - Priority flow regulator 2

Size

Seals

Blank - Buna-N V- Viton®

4

Adjustment

F - Fixed orifice

5

2

6

Port Size

3

* – ** – *.* – 00

4

5

6

7

8 7 Factory set flow rate, nominal

0 - Cartridge only

10 - 10 Size

3

1

(V) – F –

Valve housing material

(Specify in USgpm) Range 0,38-38 L/min (0.1-10 USgpm)

Code

Port Size

Housing Number - Body Only





­

Aluminum Fatigue rated

2G

1/4" BSPP



876705

3G

3/8" BSPP



876714

6H

SAE 6



876704

8H

SAE 8



876711

2G

1/4” BSPP

02-175127

3G

3/6” BSPP

02-175128

6T

SAE 6

02-175124

8T

SAE 8

02-175125

Omit for cartridge only

See section J for housing details.

Dimensions mm (inch)

Note: Torque cartridge in

Steel

8

Special features

00 - None (Only required if valve has special features, omitted if “00.”)

S - Steel A - Aluminum

housing A - 47-54 Nm (35-40 ft. lbs) S - 68-75 Nm (50-55 ft. lbs)

H Installation Drawing (Steel)

Cartridge Only Basic Code PFR15-10

25.7 (1.01)

ø 25.4 (1.00) 35.1 (1.38)

25.4 (1.00”) Hex

25.7 (1.01)

Ø25.4 (1.00)

3

63.5 (2.50) 76.2 (3.00)

2

2X Ø7.14 (0.28)

7/8-14 UNF-2A Thd

“3”

22.4 (0.88)

9.7 (0.38)

1 57.02 (2.245) 76.2 (3.00)

19.1 (0.75)

22.4 (0.88)

46.0 (1.81) “2”

WARNING Aluminum housings can be used for pressures up to 210 bar (3000 psi) Steel housings must be used for operating pressures above 210 bar (3000 psi).



ø15.78-15.82 (.621-.623)

“1” ø17.38-17.42 (.684-.686)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-221.A

PFR11-12 - Flow Regulator Fixed, priority type, pressure compensated Up to 30 L/min (8 USgpm) • 350 bar (5000 psi)

Operation 3

1

2

Sectional View

Features

Inlet flow passes through the fixed orifice and the radial holes in the spool/sleeve assembly then out of the regulated port. The pressure drop across the orifice is sensed at each end of the spool, producing a force which, at the required flow rate, overcomes the spring

force. The resultant movement of the spool regulates the flow by opening the radial valve ports to the bypass port and closing the regulated flow ports. The valve will pass flow in the return direction but this is restricted by the flow path through the control orifice.

Performance Data

Cartridge construction gives versatility of application. A valve may be fitted into a line body, a custom designed Hydraulic Integrated Circuit or directly into a cylinder or other actuator. Leakproof adjust screw gives easy, accurate adjustment to required flow setting. Hardened and ground working parts give accurate flow control and long working life.

Ratings and Specifications

3

H

2

Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49° C (120° F) Typical Application pressure (all ports) 350 bar (5000 psi) Cartridge fatigue pressure (infinite life) 350 bar (5000 psi) Rated flow Maximum inlet flow 76 L/min (20 USgpm) Maximum regulated flow 30 L/min (8 USgpm) Flow regulation accuracy 1,9-10,9 L/min (0.5-2.9 USgpm) ±15% 11,4-114 L/min (3-30 USgpm) ±10% Factory set maximum priority flow rate accuracy under standard test conditions and within the above ranges Temperature range -40° to 120°C (-40° to 248°F) Cavity C-12-3 Fluids All general purpose hydraulic fluids such as: MIL-H-5606, SAE 10, SAE 20, etc. Filtration 18/16/13 Standard housing materials Aluminum or Steel Weight cartridge only 0,25 kg (0.55 lbs) Seal kit 9900171 (Buna-N) 9900172 (Viton®) Viton is a registered trademark of E.I. DuPont

1 Description

Typical Flow Regulation

These valves are priority flow regulators. The flow (and actuator speed) will be largely independent of the load and the pressure conditions.

The valve inlet pressure will be approximately 7 bar (100 psi) more than the regulated or bypass pressure, whichever is higher.

25

210

275

A

20

60

A

10

40

B

5 0

350 100 80

B

15

0

140

20 1000

2000

3000

4000

5000

Priority flow rate - L/min (21,8 cSt oil @ 490 C)

70

0 Priority flow rate - USgpm (105 SUS oil @ 1200 F)

If used to regulate flow from a fixed supply, for example a standard gear or piston pump, the valve will pass the required flow and any surplus flow will be diverted to the bypass port. The bypass flow may be used for a secondary circuit whether the secondary pressure requirement is higher or lower than the regulated pressure.

Back pressure - bar

0

Back pressure - psi

A - Port 3, priority (regulated outlet) pressurized. B - Port 2, (bypass outlet) pressurized.

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-230.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

PFR11-12 - Flow Regulator Fixed, priority type, pressure compensated Up to 30 L/min (8 USgpm) • 350 bar (5000 psi)

Model Code

PFR11 – 12

1

1 5

Function

Size

Seals

Blank - Buna-N V- Viton®

4

3

4

5

00

6

7

Port Size

Code

12 - 12 Size

3

2

F – *** – *.* –

6

0 - Cartridge only

PFR11 - Priority flow regulator

2

(V) –

Adjustment

F - Fixed orifice

Port Size

(Specify in USgpm) Range 1,9-76 L/min (0.5-20 USgpm)

Housing Number - Body Only





Aluminium

A4G

1/2" BSPP

02-161817

A6G

3/4" BSPP

02-161816

A10H

SAE 10

02-160642

A12H

SAE 12

02-160646

S4G

1/2" BSPP

Factory set flow rate

Steel

7

Special features

00 - None (Only required if valve has special features, omitted if “00.”) 02-169815

S6G

3/4" BSPP

02-169814

S10T

SAE 10

02-161070

S12T

SAE 12

02-169816

See section J for housing details.

“S” Adjustment

Dimensions mm (inch)

H

Cartridge Only Basic Code PFR11-12

Installation Drawing (Steel) 22.9 (0.90)

31.75 (1.25”) Hex

2

22.86 (.900)

3

28.7 (1.13) 2 X Ø10.31 (0.406)

1-1/16-12 UN-2A Thd 25.4 (1.00)

12.7 (0.50)

68.48 (2.696)

51.6 (2.03)

88.9 (3.50) 101.6 (4.00)

1

25.4 (1.00)

63.50 (2.50) 88.9 (3.50)

“3” “2”

22.15-22.19 (.872-.874)

“1”

23.73-23.77 (.934-.936)

Note: Torque cartridge in aluminum housing to 81-95 Nm (60-70 ft. lbs) Note: Torque cartridge in steel housing to 102-115 Nm (75-85 ft. lbs)

WARNING Aluminum housings can be used for pressures up to 210 bar (3000 psi) Steel housings must be used for operating pressures above 210 bar (3000 psi).



Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-231.A

PFR11-16 - Flow Regulator Fixed, priority type, pressure compensated Up to 114 L/min (30 USgpm) • 350 bar (5000 psi)

Operation 3

1

2

Sectional View

Features movement of the spool regulates the flow by opening the radial valve ports to the bypass port and closing the regulated flow ports.

Inlet flow passes through the fixed orifice and the radial holes in the spool/sleeve assembly then out of the regulated port. The pressure drop across the orifice is sensed at each end of the spool, producing a force which, at the required flow rate, overcomes the spring force. The resultant

The valve will pass flow in the return direction but this is restricted by the flow path through the control orifice.

Cartridge construction gives versatility of application. A valve may be fitted into a line body, a custom designed Hydraulic Integrated Circuit or directly into a cylinder or other actuator. Leakproof adjust screw gives easy, accurate adjustment to required flow setting. Hardened and ground working parts give accurate flow control and long working life.

Performance Data Ratings and Specifications

Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49° C (120° F) Typical Application pressure (all ports) 350 bar (5000 psi) Cartridge fatigue pressure (infinite life) 350 bar (5000 psi) Rated flow Maximum inlet flow 151 L/min (40 USgpm) Maximum regulated flow 114 L/min (30 USgpm) Flow regulation accuracy 1,9-10,9 L/min (0.5-2.9 USgpm) ±15% 11,4-114 L/min (3-30 USgpm) ±10% Factory set maximum priority flow rate accuracy under standard test conditions and within the above ranges

3

Temperature range Cavity Fluids Filtration Standard housing materials Weight cartridge only Seal kit

2

Viton is a registered trademark of E.I. DuPont

H



-40° to 120°C (-40° to 248°F) C-16-3 All general purpose hydraulic fluids such as: MIL-H-5606, SAE 10, SAE 20, etc. 18/16/13 Aluminum or Steel 0,38 kg (0.84 lb.) 565811 (Buna-N), 889610 (Viton®)

1 Description

Typical Flow Regulation

The valve will pass flow in the return direction but this is restricted by the flow path through the control orifice.

Back pressure - bar 30

35

70

100

140

175

A

25

100

B

20

210 120

80 60

15 10 5

A

40

B

20

0 0

500

1000

1500

2000

2500

3000

Priority flow rate - L/min (21,8 cSt oil @ 490 C)

0 Priority flow rate - USgpm (105 SUS oil @ 1200 F)

Inlet flow passes through the fixed orifice and the radial holes in the spool/sleeve assembly then out of the regulated port. The pressure drop across the orifice is sensed at each end of the spool, producing a force which, at the required flow rate, overcomes the spring force. The resultant movement of the spool regulates the flow by opening the radial valve ports to the bypass port and closing the regulated flow ports.

0

Back pressure - psi

A - Port 3, priority (regulated outlet) pressurized. B - Port 2, (bypass outlet) pressurized.

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-240.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

PFR11-16 - Flow Regulator Fixed, priority type, pressure compensated Up to 114 L/min (30 USgpm) • 350 bar (5000 psi)

Model Code

PFR11 – 16

1

1

PFR11 - Priority flow regulator

2

Size

16 - 16 Size

3

Seals

Blank - Buna-N V- Viton®

4

2

5

Function

Adjustment

F - Fixed orifice

(V) – 3

F – *** – *.* – 4

5

00

6

7

Port Size

6

Factory set flow rate

(Specify in USgpm) Range 1,9-76 L/min (0.5-20 USgpm)

Code

Port Size

Housing Number - Body Only





Aluminium Light Duty

A12T

SAE 12

566152

A10H

SAE 10

876721

00 - None

A12H

SAE 12

876723

A4G

1/2” BSPP

876720

(Only required if valve has special features, omitted if “00.”)

A6G

3/4” BSPP

876722

S4G

1/2” BSPP

02-175131

S6G

3/4” BSPP

02-175132

Aluminum Fatigue rated

Steel

7

S10T

SAE 10

02-175129

S12T

SAE 12

02-175130

Special features

See section J for housing details.

Note: Torque cartridge in

Dimensions mm (inch)

aluminum housing to 108-122 Nm (80-90 ft. lbs)

Note: Torque cartridge in steel

housing to 136-149.6 Nm (100-110 ft. lbs)

H

Cartridge Only Basic Code PFR11-16

Installation Drawing (Steel) 36.6 (1.44)

38.1 (1.50) Hex

36.6 (1.44)

3

54.0 (2.13)

1-5/16-12 UNF-2A Thd

2 X Ø 10.31 (0.406) 25.4 (1.00)

“3”

88.9 (3.50) 108.0 (4.25)

2

12.7 (0.50)

1

76.20 (3.000)

101.6 (4.00)

25.4 (1.00)

25.4 (1.00)

73.1 (2.88) “2”

WARNING Aluminum housings can be used for pressures up to 210 bar (3000 psi) Steel housings must be used for operating pressures above 210 bar (3000 psi).



26.90-26.94 (1.059-1.061)

“1” 28.50-28.54 (1.122-1.124)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-241.A

2CFP60 - Flow Regulator Adjustable, priority type pressure compensated 4-60 L/min (1-16 USgpm) • 350 Bar (5000 psi)

Operation 3

1

2

Sectional View

Features force. The resultant movement of the spool regulates the flow by opening the radial valve ports to the bypass port and closing the regulated flow ports.

Inlet flow passes through the adjustable orifice and the radial holes in the spool/ sleeve assembly then out of the regulated port. The pressure drop across the orifice is sensed at each end of the spool, producing a force which, at the required flow rate, overcomes the spring

The valve will pass flow in the return direction but this is restricted by the flow path through the control orifice.

Cartridge construction gives versatility of application. A valve may be fitted into a line body, a custom designed Hydraulic Integrated Circuit or directly into a cylinder or other actuator. Leakproof adjust screw gives easy, accurate adjustment to required flow setting. Hardened and ground working parts give accurate flow control and long working life.

Performance Data Ratings and Specifications

Figures based on Oil Temp of 40ˆC and of 32 cST (150 SUS) Rated flow Maximum pressure Cartridge material Standard housing material Mounting position Cavity Number Torque cartridge into cavity Weight Seal kit number Recommended filtration level Operating temperature Nominal range

Reg (3)

H Bypass (2)

Inlet: 90 L/min (24 USgpm) Reg: 4-60 L/min (1-16 USgpm) 350 bar (5000 psi) Working parts hardened & ground steel. Zinc plated body Aluminum (up to 210 bar*) Add suffix “377“ for steel option Unrestricted CVA-27-04-0 (See Section M) 75 Nm (55 ft lbs) 2CFP60: 0,16 kg (0.35 lbs) 2CFP65: 1,80 kg (3.76 lbs) SK597 (Nitrile), SK597V (Viton®) BS5540/4 Class 18/13 (25 micron nominal) –30° to +90° C (–22° to +194° F) 5 to 500 cSt

Viton is a registered trademark of E.I. DuPont

Inlet (1) Description

Pressure Drop

These valves are priority flow regulators. The flow (and actuator speed) will be largely independent of the load and the pressure conditions.

Cartridge only

The valve inlet pressure will be approximately 7 bar (100 psi) more than the regulated or bypass pressure, whichever is higher.

65

5000 2500

Regulated higher than bypass pressure

0

60

2500 5000

50

55

12.5

40

45

15 10

30

7.5

25

20

5

15

10

2.5

35

0

0 350

175

0

175

Regulated flow - US gpm

Regulated flow - L/min

If used to regulate flow from a fixed supply, for example a standard gear or piston pump, the valve will pass the required flow and any surplus flow will be diverted to the bypass port. The bypass flow may be used for a secondary circuit whether the secondary pressure requirement is higher or lower than the regulated pressure.

Load pressure - psi Bypass higher than regulated pressure

350

Load pressure - bar

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-250.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

2CFP60 - Flow Regulator Adjustable, priority type pressure compensated 4-60 L/min (1-16 USgpm) • 350 Bar (5000 psi)

2CFP**

Model Code



1 1

2

3

4

S

4

5

3 Port Size

Basic Code

2CFP60 - Cartridge only 2CFP65 - Cartridge & body

2

4W –

P

Adjustment means

Code

4

Port Size

4W 1/2" BSP 8T 1/2" BSP

Aluminium B12631 B10820

Adjustable Flow Range

4 - 4-40 L/min Standard setting 30 L/min 6 - 6-60 L/min Standard setting 40 L/min

Housing Number

Steel B13664 B11566

P - Leakproof screw adjustment R - Handknob adjustment

5

Seals

S - Nitrile (for use with most industrial hydraulic oils) SV - Viton (for high temperature & most special fluid applications)

(See page H-6 for dimensions)

Note: For applications above 210 bar (3000 psi) please consult our technical department or use the steel body option.

Dimensions

mm (inch)

Cartridge Only Basic Code 2CFP60

Hex socket adjust 4.0 A/F

Complete Valve 1/2" Ports Basic Code 2CFP65 2 holes Ø11.0 (0.43) thro’ 9.0 (0.35)

17.0 A/F 49.5 (1.95) max

32.0 A/F

53.0 (2.09)

141.5 (5.57) max

H 28.5 (1.12)

3 57.0 (2.24)

2

92.0 (3.62)

1

M27 x 2.0-6g

19.0 (0.75)

19.0 (0.75)

38.1 (1.50)

65.7 (2.59) 76.2 (3.00)

38.1 (1.50)

Reg (3) 70.0 (2.76)

Bypass (2)

Inlet (1) Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-251.A

PFR12-10 - Flow Regulator Adjustable, priority type pressure compensated 38L/min (10 USgpm) • 350 bar (5000 psi)

Operation 3

1

2

Sectional View

Features

Inlet flow passes through the fixed orifice and the radial holes in the spool/sleeve assembly then out of the regulated port. The pressure drop across the orifice is sensed at each end of the spool, producing a force which, at the required flow rate, overcomes the spring

force. The resultant movement of the spool regulates the flow by opening the radial valve ports to the bypass port and closing the regulated flow ports. The valve will pass flow in the return direction but this is restricted by the flow path through the control orifice.

Cartridge construction gives versatility of application. A valve may be fitted into a line body, a custom designed Hydraulic Integrated Circuit or directly into a cylinder or other actuator. Leakproof adjust screw gives easy, accurate adjustment to required flow setting. Hardened and ground working parts give accurate flow control and long working life.

Performance Data Ratings and Specifications

H

1 Description These valves are priority flow regulators. The flow (and actuator speed) will be largely independent of the load and the pressure conditions. If used to regulate flow from a fixed supply, for example a standard gear or piston pump, the valve will pass the required flow and any surplus flow will be diverted to the bypass port. The bypass flow may be used for a secondary circuit whether the secondary pressure requirement is higher or lower than the regulated pressure. The valve inlet pressure will be approximately 7 bar (100 psi) more than the regulated or bypass pressure, whichever is higher.

Viton is a registered trademark of E.I. DuPont

Typical Flow Regulation

Back pressure - bar 35

0

70

100

140

175 210 40

A

9

B 6

A

20

B

3 0

30

10

0

500

1000

1500

2000

2500

0 3000

Priority (regulated) flow rate - L/min (21,8 cSt oil @ 49°C)

2

Priority (regulated) flow rate - USgpm (105 SUS oil @ 120°F)

3

Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49° C (120° F) Typical Application pressure (all ports) 350 bar (5000 psi) Cartridge fatigue pressure (infinite life) 350 bar (5000 psi) Rated flow Maximum inlet flow 64 L/min (17 USgpm) Maximum regulated flow 38 L/min (10 USgpm) Flow regulation accuracy 0,4-1,9 L/min (0.1-0.49 USgpm) ±20% 1,9-7,5 L/min (0.5-1.99 USgpm) ±15% 7,6-37,8 L/min (2.0-12.0 USgpm) ±10% Factory set maximum priority flow rate accuracy under standard test conditions and within the above ranges Temperature range -40° to 120°C (-40° to 248°F) Cavity C-10-3 Fluids All general purpose hydraulic fluids such as: MIL-H-5606, SAE 10, SAE 20, etc. Filtration 18/16/13 Standard housing materials Steel Weight cartridge only 0.25 kg (0.54 lb.) Seal kit 565804 (Buna-N) 889599 (Viton®)

Back pressure - psi A - Port 3, priority (regulated outlet) pressurized. B - Port 2, (bypass outlet) pressurized. Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-254.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

PFR12-10 - Flow Regulator Adjustable, priority type pressure compensated 38L/min (10 USgpm) • 350 bar (5000 psi)

Model Code

PFR12

10

(V)

*

**

*.*

00

1

2

3

4

5

6

7

1

5

Function

PFR12 - Priority flow regulator

2

Size

10 - 10 Size

3

Seals

Blank - Buna-N V- Viton

4

Adjustment

C - Cap K - Knob S - Screw

Code

Port Size

Housing Number - Body Only





Aluminum ­Fatigue rated

2G

1/4” BSPP

876705

3G

3/8” BSPP

876714

6H

SAE 6

876704

8H

SAE 8

876711

S2G

1/4” BSPP

02-175127

S3G

3/8” BSPP

02-175128

S6T

SAE 6

02-175124

S8T

SAE 8

02-175125

Note: Torque cartridge in

Dimensions mm (inch)

(Specify in USgpm) Range 0,38-37,8 L/min (0.1-10.0 USgpm)

Steel

7

Special features

00 - None (Only required if valve has special features, omitted if “00.”)

Note: Torque cartridge in

aluminum housing to 47-54 Nm (35-40 ft. lbs)

steel housing to 68-75 Nm (50-55 ft. lbs) Installation Drawing (Steel)

Cartridge Only Basic Code PFR12-10 “K” Adjustment ø 38,1 (1.50)

6 Factory set flow rate, nominal

Port Size

“S” Adjustment 4.57 Hex (.180)

H

“C” Adjustment 18.9 Hex (0.75)

79.0 (3.11) 35.1 (1.38) 3

63.5 (2.50) 76.2 (3.00)

2 79.0 (3.11)

79.0 (3.11)

2X Ø7.14 (0.28)

82.2 (3.23)

22.4 (0.88) 1” Hex

46.0 (1.81)

15.78-15.82 (.621-.623)

7/8-14 UNF-2A

17.38-17.42 (.684-.686)

9.7 (0.38)

1 57.02 (2.245) 76.2 (3.00)

19.1 (0.75)

22.4 (0.88)

WARNING Aluminum housings can be used for pressures up to 210 bar (3000 psi) Steel housings must be used for operating pressures above 210 bar (3000 psi).



Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-255.A

PFR12-12 - Flow Regulator Adjustable, priority type, pressure compensated 45 L/min (12 USgpm) • 350 bar (5000 psi)

Operation 3

1

2

Sectional View

Features

Inlet flow passes through the fixed orifice and the radial holes in the spool/sleeve assembly then out of the regulated port. The pressure drop across the orifice is sensed at each end of the spool, producing a force which, at the required flow rate, overcomes the spring

force. The resultant movement of the spool regulates the flow by opening the radial valve ports to the bypass port and closing the regulated flow ports. The valve will pass flow in the return direction but this is restricted by the flow path through the control orifice.

Cartridge construction gives versatility of application. A valve may be fitted into a line body, a custom designed Hydraulic Integrated Circuit or directly into a cylinder or other actuator. Leakproof adjust screw gives easy, accurate adjustment to required flow setting. Hardened and ground working parts give accurate flow control and long working life.

Performance Data Ratings and Specifications

H

1 Description These valves are priority flow regulators. The flow (and actuator speed) will be largely independent of the load and the pressure conditions. If used to regulate flow from a fixed supply, for example a standard gear or piston pump, the valve will pass the required flow and any surplus flow will be diverted to the bypass port. The bypass flow may be used for a secondary circuit whether the secondary pressure requirement is higher or lower than the regulated pressure. The valve inlet pressure will be approximately 7 bar (100 psi) more than the regulated or bypass pressure, whichever is higher.

Viton is a registered trademark of E.I. DuPont

Typical Flow Regulation Back pressure - bar 0 25

70

140

210

275

A

20

80

B

15

60 A

10

40

B 20

5 0

350 100

0

1000

2000

3000

4000

5000

Priority flow rate - L/min (21,8 cSt oil @ 490 C)

2

Priority flow rate - USgpm (105 SUS oil @ 1200 F)

3

Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49° C (120° F) Typical Application pressure (all ports) 350 bar (5000 psi) Cartridge fatigue pressure (infinite life) 350 bar (5000 psi) Rated flow Maximum inlet flow 114 L/min (30 USgpm) Maximum regulated flow 45 L/min (12 USgpm) Flow regulation accuracy 0,4-1,9 L/min (0.1-0.49 USgpm) ±20% 1,9-7,5 L/min (0.5-1.99 USgpm) ±15% 7,6-37,8 L/min (2.0-12.0 USgpm) ±10% Factory set maximum priority flow rate accuracy under standard test conditions and within the above ranges Temperature range -40° to 120°C (-40° to 248°F) Cavity C-12-3 Fluids All general purpose hydraulic fluids such as: MIL-H-5606, SAE 10, SAE 20, etc. Filtration 18/16/13 Standard housing materials Aluminum or Steel Weight cartridge only 0,32 kg (0.70 lb.) Seal kit 9900171 (Buna-N) 9900172 (Viton®)

0

Back pressure - psi A - Port 3, priority (regulated outlet) pressurized. B - Port 2, (bypass outlet) pressurized. Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-260.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

PFR12-12 - Flow Regulator Adjustable, priority type, pressure compensated 45 L/min (12 USgpm) • 350 bar (5000 psi)

Model Code

PFR12 – 12

1

1

PFR12 - Priority flow regulator

2

5

Function

(V) – 3

* – 4

** – *.* – 00 5

6

6 Factory set flow rate, nominal

Port Size

0 - Cartridge only Code

Port Size

Housing Number - Body Only





Aluminum ­Fatigue rated

A4G

1/2” BSPP

02-161817

A6G

3/4” BSPP

02-161816

A10H

SAE 10

02-160642

A12H

SAE 12

02-160646

S4G

1/2” BSPP

02-169815

S6G

3/4” BSPP

02-169814

C - Cap K - Knob S - Screw

S10T

SAE 10

02-161070

S12T

SAE 12

02-169816

Dimensions mm (inch)

Note: Torque cartridge in alu-

2

Size

12 - 12 Size

3

Seals

Blank - Buna-N V- Viton

4

Adjustment

Steel

(Specify in USgpm) Range 0,38-37,8 L/min (0.1-10.0 USgpm)

7

Special features

00 - None (Only required if valve has special features, omitted if “00.”)

See section J for housing details.

minum housing to 81-95 Nm (60-70 ft. lbs)

Note: Torque cartridge in steel

housing to 102-115 Nm (75-85 ft. lbs) Installation Drawing (Steel)

Cartridge Only Basic Code PFR12-12 “K” Adjustment

7

“S” Adjustment

H

“C” Adjustment

18.9 (.75) Hex

83.95 (3.305)

87.23 (3.434)

1-1/4” Hex

68.48 (2.696) 1-1/16-12-UN-2A

“3”

WARNING

“2”

22.15-22.19 (.872-.874)

“1”

Aluminum housings can be used for pressures up to 210 bar (3000 psi) Steel housings must be used for operating pressures above 210 bar (3000 psi).



23.73-23.77 (.934-.936)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-261.A

PFR2-16 - Flow Regulator Limited range adjustable, priority pressure compensated 114 L/min (30 USgpm) • 210 Bar (3000 psi)

Operation 3

1

2

Sectional View

Features

Inlet flow passes through the fixed orifice and the radial holes in the spool/sleeve assembly then out of the regulated port. The pressure drop across the orifice is sensed at each end of the spool, producing a force which, at the required flow rate, overcomes the spring force. The

resultant movement of the spool regulates the flow by opening the radial valve ports to the bypass port and closing the regulated flow ports. The valve will pass flow in the return direction but this is restricted by the flow path through the control orifice.

Cartridge construction gives versatility of application. A valve may be fitted into a line body, a custom designed Hydraulic Integrated Circuit or directly into a cylinder or other actuator. Leakproof adjust screw gives easy, accurate adjustment to required flow setting. Hardened and ground working parts give accurate flow control and long working life.

Performance Data Ratings and Specification

Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F) Typical application pressure (all ports) 210 bar (3000 psi) Cartridge fatigue pressure (infinite life) 210 bar (3000 psi) Rated flow Maximum inlet flow 151 L/min (40 USgpm) Maximum regulated flow 114 L/min (30 USgpm) Temperature range -40° to 120°C (-40° to 248°F)) Flow regulation accuracy 1,9–10,9 L/min (0.5–2.9 USgpm) ±15% 11,4–114 L/min (3–30 USgpm) ±10% Factory set maximum flow rate accuracy under standard test conditions and within the above ranges

3 2

H

1

Cavity Fluids Filtration Standard housing material Weight cartridge only Seal kit

C–16–3 All general purpose hydraulic fluids such as MIL-H-5606, SAE 10, SAE 20 etc. Cleanliness code 18/16/13 Aluminum or Steel 0,43 kg (0.95 lbs) 565811 (Buna-N) 889610 (Viton®)

Viton is a registered trademark of E.I. DuPont

Cartridge only

If used to regulate flow from a fixed supply, for example a standard gear or piston pump, the valve will pass the required flow and any surplus flow will be diverted to the bypass port. The bypass flow may be used for a secondary circuit whether the secondary pressure requirement is higher or lower than the regulated pressure. The valve inlet pressure will be approximately 7 bar (100 psi) more than the regulated or bypass pressure, whichever is higher.

35

0

Back pressure - bar 75 100 140

175

100

25

A

20

80 B

15

60

A 40

10

B 20

5 0

210

0

500

1000 1500 2000 Back pressure - psi

A - Port 3, priority (regulated) outlet pressurized B - Port 2, bypass outlet pressurized

2500

0 3000

Priority (regulated) flow rate - L/min (21,8 cSt oil @ 49°C)

Typical Flow Regulation

These valves are priority flow regulators. The flow (and actuator speed) will be largely independent of the load and the pressure conditions.

Priority (regulated) flow rate - USgpm (105 SUS oil @ 120°F)

Description

Note: The flow adjustment is from the factory - set maximum flow rate down to 50% of that factory set flow rate.

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-270.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

PFR2-16 - Flow Regulator Limited range adjustable, priority pressure compensated 114 L/min (30 USgpm) • 210 Bar (3000 psi)

PFR2 – 16

Model Code

1 1 Function

(V) – * – *** – *.* – 00

2

3

4

5

6

7 6 Factory Set Flow Rate

5 Port Size

PFR2 - Priority flow regulator

Code

Port Size

Housing Number

0 Cartridge only 12T SAE 12 6B 3/4" BSPP 10H SAE 10 12H SAE 12 4G 1/2" BSPP 6G 3/4” BSPP

2 Size 16 - 16 size

3 Seals Blank - Buna-N V - Viton®

4 Adjustment C - Cap K - Knob S - Screw

See section J for housing details.

Dimensions

Torque cartridge in aluminum housing to 108–122 Nm (80–90 ft lbs).

mm (inch)

Cartridge Only Basic Code PFR2-16

(Specify in USgpm) Range 1,9–114 L/min (0.5–30 USgpm)

Aluminium Light Duty

Aluminum Fatigue Rated

566152 02-175465 – – – –

– – 876721 876723 876720 876722

7 Special Features 00 – None (Only required if valve has special features, omitted if “00”) SS - 316 stainless steel external components

Installation Drawing

"C" Adjustment 19,0 (0.75) hex

H

"S" Adjustment 9,6 (0.37) hex

19.0 HEX (0.75)

"K" Adjustment, Ø51 (2.0)

107.9 (4.25) 31.8 (1.25)

107,2 (4.22)

104,0 (4.09)

57.0 (2.24)

38.1 HEX 31.8 (1.50) (1.25)

88.9 (3.50)

28.4 (1.12)

3

114.3 (4.50)

38,1 (1.50) hex

1 10.3 (0.41)

1.312" -12 Thd. 73,0 (2.87)

2

93.68 114.6 (3.688) (4.50)

2 x 8.74 (0.344)

3 2 1

Ø26,95 (1.061) Ø28,55 (1.124)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-271.A

PFR12-16 - Flow Regulator Adjustable, priority type, pressure compensated 114 L/min (30 USgpm) • 350 bar (5000 psi)

Operation 3

1

2

Features force. The resultant movement of the spool regulates the flow by opening the radial valve ports to the bypass port and closing the regulated flow ports.

Inlet flow passes through the fixed orifice and the radial holes in the spool/sleeve assembly then out of the regulated port. The pressure drop across the orifice is sensed at each end of the spool, producing a force which, at the required flow rate, overcomes the spring

The valve will pass flow in the return direction but this is restricted by the flow path through the control orifice.

Performance Data

Sectional View

Cartridge construction gives versatility of application. A valve may be fitted into a line body, a custom designed Hydraulic Integrated Circuit or directly into a cylinder or other actuator. Leakproof adjust screw gives easy, accurate adjustment to required flow setting. Hardened and ground working parts give accurate flow control and long working life.

Ratings and Specifications

Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49° C (120° F) Typical Application pressure (all ports) 350 bar (5000 psi) Cartridge fatigue pressure (infinite life) 350 bar (5000 psi) Rated flow Maximum inlet flow 151 L/min (40 USgpm) Maximum regulated flow 114 L/min (30 USgpm) Flow regulation accuracy 1,9-10,9 L/min (0.5-2.9 USgpm) ±15%* 11,4-114 L/min (3-30 USgpm) ±10%* * Factory set maximum priority flow rate accuracy under standard test conditions and within the above ranges

3

H

2

Temperature range Cavity Fluids Filtration Standard housing materials Weight cartridge only Seal kit

-40° to 120°C (-40° to 248°F) C-16-3 All general purpose hydraulic fluids such as: MIL-H-5606, SAE 10, SAE 20, etc. 18/16/13 Aluminum or Steel 0,43 kg (0.95 lb.) 565811 (Buna-N) 889610 (Viton®)

Viton is a registered trademark of E.I. DuPont

1 Typical Flow Regulation

If used to regulate flow from a fixed supply, for example a standard gear or piston pump, the valve will pass the required flow and any surplus flow will be diverted to the bypass port. The bypass flow may be used for a secondary circuit whether the secondary pressure requirement is higher or lower than the regulated pressure. The valve inlet pressure will be approximately 7 bar (100 psi) more than the regulated or bypass pressure, whichever is higher.

Back pressure - bar 35

0 25

70

100

140

175

A

20

80

B

15

60

A

10

40

B

20

5 0

0

210 100

500

1000

1500

2000

2500

3000

Priority flow rate - L/min (21,8 cSt oil @ 490 C)

These valves are priority flow regulators. The flow (and actuator speed) will be largely independent of the load and the pressure conditions.

Priority flow rate - USgpm (105 SUS oil @ 1200 F)

Description

0

Back pressure - psi

A - Port 3, priority (regulated outlet) pressurized. B - Port 2, (bypass outlet) pressurized.

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-280.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

PFR12-16 - Flow Regulator Adjustable, priority type, pressure compensated 114 L/min (30 USgpm) • 350 bar (5000 psi)

Model Code

PFR12 – 16



1 5

1 Function PFR12 - Priority flow regulator 2

Size

16 - 16 Size

3

Seals

Blank - Buna-N V- Viton®

4

2

Adjustment Means

C - Cap K - Knob S - Screw

(V) –

* – ** – *.* – 00

3

4

5

6

7 6 Factory set flow rate, nominal

Port Size

Code

Port Size

Housing Number- Body Only





Aluminum ­Fatigue rated

0

Cartridge only

A10H

SAE 10

876721

A12H

SAE 12

876723

00 - None

A4G

1/2” BSPP

876720

A6G

3/4” BSPP

876722

(Only required if valve has special features, omitted if “00.”)

S4G

1/2” BSPP

02-175131

S6G

3/4” BSPP

02-175132

S10T

SAE 10

02-175129

S12T

SAE 12

02-175130

(Specify in USgpm) Range 1,9-114 L/min (0.5-30 USgpm)

Steel

7

Special features

See section J for housing details.

Dimensions mm (inch) Cartridge Only Basic Code PFR12-16

Installation Drawing (Steel)

H

"C" Adjustment 19,0 (0.75) hex

"S" Adjustment 9,6 (0.37) hex "K" Adjustment, Ø51 (2.0)

112.1 (4.41)

108.2 (4.26)

100.8 (3.97)

3

54.0 (2.13) 2 X Ø 10.31 (0.406)

38,1 (1.50) hex

25.4 (1.00)

12.7 (0.50)

1.312" -12 Thd. 73,0 (2.87)

88.9 (3.50) 108.0 (4.25)

2 1

76.20 (3.000)

101.6 (4.00)

25.4 (1.00)

25.4 (1.00)

3 WARNING

2 1

Note: Torque cartridge in

Ø26,95 (1.061) Ø28,55 (1.124)

aluminum housing to 108-122 Nm (80-90 ft. lbs) Note: Torque cartridge in steel

housing to 136-149.6 Nm (100-110 ft. lbs)

Aluminum housings can be used for pressures up to 210 bar (3000 psi) Steel housings must be used for operating pressures above 210 bar (3000 psi).



Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-281.A

PFRD/S-12 - Priority Flow Control Spool Type, Load Sensing 76 L/min (20 USgpm) • 280 Bar (4000 psi)

Operation

Dynamic Signal (PFRD) 2 (EF)

4 (CF)

2

1

5 (LS)

3 (P)

Static Signal (PFRS 2 (EF)

4 (CF)

2

1

5 (LS)

3 (P)

Sectional View

Features

This valve is used in the flow control mode. Pump flow from the valve inlet port 3 is delivered first to port 4 at a fixed rate; excess flow is bypassed to port 2. The valve maintains the controlled flow to 4 regardless of inlet pressure change or load pressure changes at 2 or 4. This valve is typically used with open loop load sense systems in steering and braking circuits. The static type is used for less difficult applications where response or circuit stability is not a problem. The dynamic type is used for difficult applications where response or circuit

stability are critical. The load sense line connected to port 5 should not exceed 2 Meters (6 Feet) in length. Overpressure protection for the circuits connected to ports 2 and 4 must be provided by external relief valves. The control pressure is determined by ­assuring adequate inlet pressure to the ­steering unit and must be matched to the steering unit’s required flow. The control pressure must be supplied to the valve as a minimum inlet pressure. The ­pressure at port 4 can vary by 10% when the load at the excess flow port 2 varies from 0 to maximum pressure.

Hardened and ground working parts to limit leakage and extend service life. Robust design with a 280 bar max pressure rating.

Performance Data Ratings and Specifications

H

5

(LS)

4 (CF) 3

(P)

2

(EF)

Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F) Typical application pressure (all ports) 280 bar (4000 psi) Cartridge fatigue pressure (infinite life) 280 bar (4000 psi) Rated inlet flow 76 L/min (20 USgpm) Temperature range -40° to 120°C (-40° to 248°F)) Cavity C–12–5S Fluids All general purpose hydraulic fluids such as: MIL-H-5606, SAE 10, SAE 20 etc. Filtration Cleanliness code 18/16/13 Standard housing material Aluminum or steel Weight cartridge only 0,36 kg (0.79 lb) Seal kit 202914-921 Internal leakage 164cc/min (10 in 3/min) @ 3000 PSID Recommended L/S orifice 0.031" (not included in valve)

Pressure Drop Cartridge only

1

Flow - L/min

This is a load sense priority flow regulator designed to provide a controlled pressure compensated flow on demand. The valve is ideal for steering or accumulator charging circuits.

Pressure drop psi

Description

290

20

30

40

50

60

70

80

90 20

218

15

145

10 5

73 0

0

5

10 15 Flow - USgpm P to EF

20

Pressure drop bar

Note: Port 1 unused, port should be plugged.

10

Note: Minimum inlet flow should not be less than 1/4 of maximum inlet flow. Minimum pressure drop is determined by control pressure.

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-290.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

PFRD/S-12 - Priority Flow Control Spool Type, Load Sensing 76 L/min (20 USgpm) • 280 Bar (4000 psi)

PFR* – 12

Model Code

1 1 Function

2

U – * – *** – *** – 00 3

4

5

6

7

5 Port Size

PFRS - Priority flow regulator

Code

Static signal type PFRD - Priority flow regulator Dynamic signal type

6 Control Pressure

Port Size

Housing Number

Port 2, 3, 4 Port 5 Aluminium 000 No Body – – 10T SAE 10 SAE 4 4998820-001 12T SAE 12 SAE 4 4998820-002 04G 1/2" BSPP 1/4" BSPP 4998820-003 06G 3/4” BSPP 1/4" BSPP 4998820-004 *These model digits will not be stamped on the valve. See section J for housing details.

2 Size 12 - 12 size

3 Seal Material U - Urethane (standard)

PFRS options Steel – 4998821-001 4998821-002 4998821-003 4998821-004

055 - 55 psi (3.8 bar) 078 - 78 psi (5.4 bar) 100 - 100 psi (6.9 bar) PFRD options 075 - 75 psi (5.2 bar) 110 - 110 psi (7.6 bar) 145 - 145 psi (10.0 bar)

7 Special Features

4 Valve Housing Material

00 - None

O - Cartridge only A - Aluminum S - Steel (standard)

(Only required if valve has special features, omit if ("00")

Torque cartridge in housing A - 81-95 Nm (60-70 ft lbs) S - 102-115 Nm (75-85 ft lbs)

Dimensions

mm (inch)

Cartridge Only Basic Code PFRD/S-12

Note: Standard housings include port 1, however for most applications this port must be blocked.

H

Installation Drawing (Steel)

33.3 (1.31)

33.3 (1.31)

34.1 (1.34)

1 1/4" HEX

5

1 1/16"-1 2 UN-2A

101.6 (4.00) 113.5 (4.47)

76.1 (3.00)

5 LS

4

50.04 (1.970)

25.0 (0.99) 12.3 (0.49)

54 (2.13)

3 2

1

4 CF

86.4 (3.40)

16.7 (0.66)

2 x 08.74 (0.344) 25 (0.99)

76.2 (3.00) 100.8 (3.97)

3 P 2 EF 1

WARNING Aluminum housings can be used for pressures up to 210 bar (3000 psi). Steel housings must be used for operating pressures above 210 bar (3000 psi).



Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-291.A

PFRD/S-16 - Priority Flow Control Spool Type, Load-Sensing 150 L/min (40 USgpm) • 280 bar (4000 psi)

Operation

Dynamic Signal (PFRD) 2 (EF)

4 (CF)

2

1

5 (LS)

3 (P)

Static Signal (PFRS) 2 (EF)

4 (CF)

2

1

5 (LS)

3 (P)

Sectional View

Features

This valve is used in the flow control mode. Pump flow from the valve inlet port 3 is delivered first to port 4 at a fixed rate; excess flow is bypassed to port 2. The valve maintains the controlled flow to 4 regardless of inlet pressure change or load pressure changes at 2 or 4. This valve is typically used with open loop load sense systems in steering and braking circuits. The static type is used for less difficult applications where response or circuit stability is not a problem. The dynamic type is used for difficult applications where response or circuit

stability are critical. The load sense line connected to port 5 should not exceed 2 Meters (6 Feet) in length. Overpressure protection for the circuits connected to ports 2 and 4 must be provided by external relief valves. The control pressure is determined by ­assuring adequate inlet pressure to the ­steering unit and must be matched to the steering unit’s required flow. The control pressure must be supplied to the valve as a minimum inlet pressure. The ­pressure at port 4 can vary by 10% when the load at the excess flow port 2 varies from 0 to maximum pressure.

Hardened and ground working parts to limit leakage and extend service life. Robust design with a 280 bar max pressure rating.

Performance Data Ratings and Specifications

5 (LS)

H 4 (CF)

3 (P)

Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F) Typical application pressure (all ports) 280 bar (4000 psi) Cartridge fatigue pressure (infinite life) 280 bar (4000 psi) Rated inlet flow 150 L/min (40 USgpm) Temperature range -40° to 120°C (-40° to 248°F)) Cavity C–16–5S Fluids All general purpose hydraulic fluids such as: MIL-H-5606, SAE 10, SAE 20 etc. Filtration Cleanliness code 18/16/13 Standard housing material Aluminum or Steel Weight cartridge only 0,47 kg (1.05 lbs) Seal kit 202915-922 Internal leakage 164cc/min (10 in 3/min) @ 3000 PSID Recommended L/S orifice 0.036" (not included in valve)

2 (EF) Pressure Drop

Description This is a load sense priority flow regulator designed to provide a controlled pressure compensated flow on demand. The valve is ideal for steering or accumulator charging circuits.

Pressure drop psi

250

Note Port 1 unused, port should be plugged.

Flow - L/min 75 114

38

151

200

14

150

10

100

7

50

3

0

0

5

10

15

20 25 30 Flow - USgpm P to EF

35

40

45

Pressure drop bar

Cartridge only 1

Note: Minimum inlet flow should not be less than 1/4 of maximum inlet flow. Minimum pressure drop is determined by control pressure.

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-300.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

PFRD/S-16 - Priority Flow Control Spool Type, Load-Sensing 150 L/min (40 USgpm) • 280 bar (4000 psi)

PFR* – 16

Model Code

1

2

U – * – *** – *** – 00 3

4

5

6

7

4 Valve Housing Material

1 Function

O - Cartridge only A - Aluminum

PFRS - Priority flow regulator Static signal type PFRD - Priority flow regulator Dynamic signal type

6 Control Pressure S - Steel (standard)

5 Port Size Code

2 Size

Port Size

Housing Number

Port 2, 3, 4 Port 5 Aluminium 000 No Body – – 12T SAE 12 SAE 4 4994880-001 16T SAE 16 SAE 4 4994880-002 06G 3/4" BSPP 1/4" BSPP 4994880-003 08G 1" BSPP 1/4" BSPP 4994880-004 *These model digits will not be stamped on the valve.

16 - 16 size

3 Seal Material U - Urethane (standard)

Steel – 4994881-001 4994881-002 4994881-003 4994881-004

See section J for housing details.

Torque cartridge in housing A - 108-122 Nm (80-90 ft lbs) B - 136-149 Nm (100-110 ft lbs)

Dimensions

mm (inch)

Cartridge Only Basic Code PFRD/S-16

PFRS options 065 - 65 psi (4.5 bar) 130 - 130 psi (8.9 bar) 100 - 100 psi (11.0 bar) PFRD options 080 - 80 psi (5.5 bar) 110 - 110 psi (7.6 bar) 130 - 130 psi (9.0 bar)

7 Special Features 00 - None (Only required if valve has special features, omit if ("00")

Note: Standard housings include port 1, however for most applications this port must be blocked. Installation Drawing (Steel) 17.8 (0.70)

36.1 (1.42)

1.50" HEX

17.8 (.70)

5

1 5/16"-2 UN-2A

114.3 (4.50) 126.2 (4.97)

85.7 (3.38)

5 LS

4 CF 96.3 (3.79)

H

31.4 (1.23) 62.74 (2.470)

9.5 (0.37)

4 3

16.9 (0.66) 58.7 (2.31)

2 1 95.25 (3.750) 113.5 (4.47)

2 x 08.74 (0.344) 31.4 (1.23)

3 P

2 EF

WARNING Aluminum housings can be used for pressures up to 210 bar (3000 psi). Steel housings must be used for operating pressures above 210 bar (3000 psi).



1

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-301.A

PFRD/S-20 - Priority Flow Control Spool type, load-sensing 230 L/min (60 USgpm) • 240 bar (3500 psi)

Operation

Dynamic Signal (PFRD) 2 (EF)

4 (CF)

2

1

5 (LS)

3 (P)

Static Signal (PFRS) 2 (EF)

4 (CF)

2

1

5 (LS)

3 (P)

Sectional View

Features

This valve is used in the flow control mode. Pump flow from the valve inlet port 3 is delivered first to port 4 at a fixed rate; excess flow is bypassed to port 2. The valve maintains the controlled flow to 4 regardless of inlet pressure change or load pressure changes at 2 or 4. This valve is typically used with open loop load sense systems in steering and braking circuits. The static type is used for less difficult applications where response or circuit stability is not a problem. The dynamic type is used for difficult applications where response or circuit

stability are critical. The load sense line connected to port 5 should not exceed 2 Meters (6 Feet) in length. Overpressure protection for the circuits connected to ports 2 and 4 must be provided by external relief valves. The control pressure is determined by ­assuring adequate inlet pressure to the ­steering unit and must be matched to the steering unit’s required flow. The control pressure must be supplied to the valve as a minimum inlet pressure. The ­pressure at port 4 can vary by 10% when the load at the excess flow port 2 varies from 0 to maximum pressure.

Hardened and ground working parts to limit leakage and extend service life. Robust design with a 280 bar max pressure rating.

Performance Data Ratings and Specifications

5 (LS)

H

4 (CF)

3 (P)

Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F) Typical application pressure (all ports) 240 bar (3500 psi) Cartridge fatigue pressure (infinite life) 240 bar (3500 psi) Rated inlet flow 230 L/min (60 USgpm) Temperature range -40° to 120°C (-40° to 248°F)) Cavity C–20–5S Fluids All general purpose hydraulic fluids such as: MIL-H-5606, SAE 10, SAE 20 etc. Filtration Cleanliness code 18/16/13 Standard housing material Aluminum or Steel Weight cartridge only 0,86 kg (1.9 lbs) Seal kit 02-187543 Internal leakage 164cc/min (10 in 3/min) @ 3000 PSID Recommended L/S orifice 0.047" (not included in valve)

2 (EF) Pressure Drop Cartridge only 250

Description This is a load sense priority flow regulator designed to provide a controlled pressure compensated flow on demand. The valve is ideal for steering or accumulator charging circuits.

227

14

200 Pressure drop psi

Note: Port 1 unused, port should be plugged.

151

150 7

100 50 0

10

20

30

40

50

60

Pressure drop bar

1

Flow - L/min 75

Note: Minimum inlet flow should not be less than 1/4 of maximum inlet flow. Minimum pressure drop is determined by control pressure.

Inlet flow (GPM)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-310.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

PFRD/S-20 - Priority Flow Control Spool type, load-sensing 230 L/min (60 USgpm) • 240 bar (3500 psi)

PFR* – 20

Model Code

1

2

U – * – *** – *** – 00 3

4

5

6

7

4 Valve Housing Material

1 Function PFRS - Priority flow regulator Static signal type PFRD - Priority flow regulator Dynamic signal type

O - Cartridge only A - Aluminum

6 Control Pressure PFRS options 080 - 80 psi (5.5 bar) 100 - 100 psi (6.9 bar) PFRD options 085 - 85 psi (5.9 bar) 110 - 110 psi (7.6 bar)

S - Steel (standard)

5 Port Size Code

2 Size

Port Size

Housing Number

Port 2, 3, 4 Port 5 Aluminium 000 No Body – – 12T SAE 12 SAE 4 4998822-001 16T SAE 16 SAE 4 4998822-002 06G 3/4" BSPP 1/4" BSPP 4998822-003 08G 1" BSPP 1/4" BSPP 4998822-004 *These model digits will not be stamped on the valve.

20 - 20 size

3 Seal Material U - Urethane (standard)

Steel – 4998823-001 4998823-002 4998823-003 4998823-004

7 Special Features 00 - None (Only required if valve has special features, omit if ("00")

See section J for housing details.

Torque cartridge in housing A - 130-155 Nm (95-115 ft lbs) B - 160-180 Nm (120-135 ft lbs)

Dimensions

mm (inch)

Cartridge Only Basic Code PFRD/S-20

Note: Standard housings include port 1, however for most applications this port must be blocked.

H

Installation Drawing (Steel) 20.3 (0.80)

1 7/8 HEX.

20,3 (.80)

37.6 (1.48) 87.4 138.9 (3.44) (5.47)

1 5/8 -12 UN-2A 5 LS

4 CF 105,2 (4.14)

5 4 3 2

16.8 (0.66) 62.3 (2.45)

1 75 (2.97)

12.7 (0.50)

114.3 (4.50) 126.24 (4.970)

2 x 010.31 (0.406)

3 P

2 EF

WARNING Aluminum housings can be used for pressures up to 210 bar (3000 psi). Steel housings must be used for operating pressures above 210 bar (3000 psi).



1

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-311.A

MRV2-10 - Flow Restrictor Valve Semi-rotary Up to 57 L/min (15 USgpm) • 210 Bar (3000 psi)

2

1

Operation

Features

This valve will increase or decrease flow by changing the variable orifice with the rotary adjustment. Recommended flow path is 2 to 1.

Hardened and ground working components. Cartridge construction for maximum mounting flexibility. Flexible mounting for the handle position, detent available.

Performance Data

Sectional View

Ratings and Specifications

Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F) Typical application pressure (all ports) 210 bar (3000 psi) Rated inlet flow 05 – 0-18,9 L/min (0–5 USgpm) 10 – 0-37,8 L/min (0–10 USgpm) 15 – 0-56,7 L/min (0–15 USgpm) Internal leakage 164 cm3/min (10 in3/min) maximum 210 bar (3000 psi) Temperature range Manual operators * Light duty housing only Cavity Fluids Filtration Standard housing material Weight cartridge only Seal kit

2

1

H

-40° to 120°C (-40° to 248°F)) B– Ball lever (friction lock)* E – Ball lever (10 position detent)* D – Lever (10 position detent)* L– Lever (friction lock)* K- Knob (non-locking) C–10–2 All general purpose hydraulic fluids such as: MIL-H-5606, SAE 10, SAE 20 etc. Cleanliness code 18/16/13 Aluminum 0,79 kg (1.74 lbs) 561810 (Buna-N), 889609 (Viton®)

Viton is a registered trademark of E.I. DuPont

Pressure Drop

Description

Cartridge only

@ 5,5 bar (80 psi) pressure drop

Flow-L/min(21,8cStoil@49°C) 10

9

20

30

A

8 Knob lever position

This is a 2 way 2 position manually operated semi rotary restrictor screw in cartridge valve. This can be used in conjunction with a compensator to give an increase in flow in proportion to the movement of the lever.

40

B

50

60 C

7 6 5 4 3 2 1 0

0

2 4 6 8 10 12 Flow - USgpm (105 SUS oil @ 120°F)

14

Rated flow (See model code position 6) A - 05 B - 10 C - 15 Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-320.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

MRV2-10 - Flow Restrictor Valve Semi-rotary Up to 57 L/min (15 USgpm) • 210 Bar (3000 psi)

1 1 Function

(V) – * – ** – ** – 00

2

3

4

5

6

7 6 Max Flow Ranges

4 Adjustment

MRV2 - Manual rotary valve

2 Size 10 - 10 size

D - Lever (10 position detent)* L - Lever (friction lock)* K - Knob (non-locking)

O - Cartridge only B - Ball lever (friction lock)* E - Ball lever (10 position detent)*

*Light duty housings only

3 Seal Material

Code

Port Size

Housing Number

Cartridge only 0 3B 3/8” BSPP 6T SAE 6 2G 1/4" BSPP 3G 3/8" BSPP 6H SAE 6 8H SAE 8 See section J for housing details.

05 - 0-18,9 L/min (0-5 USgpm) 10 - 0-37,8 L/min (0-10 USgpm) 15 - 0-56,7 L/min (0-15 USgpm)

7 Special Features

5 Port Size

Blank - Buna-N V- Viton®

Aluminium Light duty

Aluminium Fatigue rated

02-175462 566151 – – – –

– – 876702 876703 876700 876701

00 - None (Only required if valve has special features, omit if ("00") SS - 316 Stainless Steel external components

Dimensions

mm (inch) Torque cartridge in aluminum housing 47-54 Nm (35-50 ft lbs)

Cartridge Only Basic Code MVR2-10

Ø25,4 Ø25,4(1.00) (1.00)

X

X

42,0 42,0 (1.65) MRV2-10-B/E Models (1.65)

MRV2-10-B/E Models Ø25,4 (1.00) 37,0 Ø25,4 (1.00) 37 ,0 (1.45) (1.45) 25,4 (1.00) hex 41,0 38,1 25,4 (1.00) hex (1.60) 0.875"-14 Thd.? (1.50) 41,0 31,7 38,1 0.875"-14 Thd.? (1.60) X X (1.50) 2 (1.25) 31,7 2 (1.25) X X 42,0 1 (1.65) 42,0Ø15,80 (0.622) 1 (1.65) Ø15,80 (0.622) MRV2-10-E/D Models

25,4 (1.00) hex

25,4 (1.00) Thd.? hex 0.875"-14

17,0 MRV2-10-E/D Models Locating (0.67) 17,0 pin hole Locating (0.67) pin hole

0.875"-14 Thd.?

Ø15,80 (0.622)

An Eaton Brand

38,1 38,1 (1.50) (1.50)

X

(1.45) 41,0 41,0 (1.60) (1.60)

X X 63.5

(2.50)

42,0 42,0 (1.65) (1.65)Models MRV2-10-D/L

44.5 (1.75) X X

9.1 (0.75) 58,058,0 2 (2.28) (2.28)

1

MRV2-10-D/L Models 41,0 Models MRV2-10-E/D MRV2-10-B/L Models 9.5 44.46 (1.60) Models MRV2-10-E/D MRV2-10-B/L Models (0.37) 17,0 41,0 (1.750) Locating Locating 17,0 (1.60) (0.67) pin Locating hole Locating pin hole (0.67) pin63.5 hole pin hole (2.50) 58,0 (2.28) X 58,0 X (2.28) X Ø3,45-3,50 0 X (#29 or 0.136+0.002) Ø3,45-3,50 0 x(#29 4,76or(0.187) 0.136+0.002) in mating housing x 4,76 (0.187)

2 x 7.14 (0.281)

1

in mating housing MRV2-10-B/L Models

MRV2-10-B/L Models Locating pin hole Locating pin hole

Ø3,45-3,50 0 (#29 or 0.136+0.002) Ø3,45-3,50 x 4,76 (0.187) 0 (#29 or 0.136+0.002) in mating housing x 4,76 (0.187) in mating housing

Ø15,80 (0.622)

H

MRV2-10-D/L 36.8 Models MRV2-10-D/L Models

MRV2-10-B/E MRV2-10-B/EModels Models

41,0 41,0 (1.60) (1.60) X

Re-tighten nut.

Installation Drawing 25.4 (1.00)

MRV2-10-KKnob KnobOperated Operated MRV2-10-K Arrowcan canbe bere-located re-located by by Arrow slackingthe theplate. plate.Re-tighten Re-tighten nut. nut. slacking

b Operated ocated by Operated . Re-tighten nut. cated by

2

MRV2 – 10

Model Code

WARNING Aluminum housings can be used for pressures up to 210 bar (3000 psi). Steel housings must be used for operating pressures above 210 bar (3000 psi).



Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-321.A

MRV2-16 - Flow Restrictor Valve Semi-rotary Up to 170 L/min (45 USgpm) • 210 bar (3000 psi)

2

1

Operation

Features

This valve will increase or decrease flow by changing the variable orifice with the rotary adjustment. Recommended flow path is 2 to 1.

Hardened and ground working components. Cartridge construction for maximum mounting flexibility. Flexible mounting for the handle position, detent available.

Performance Data

Sectional View

Ratings and Specifications

Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F) Typical application pressure (all ports) Rated inlet flow Internal leakage Temperature range Manual Operators *Light duty housing only. Cavity Fluids Filtration Standard housing material Weight cartridge only Seal kit

2

1

H

210 bar (3000 psi) 10 – 0-37,8 L/min (0–10 USgpm) 15 – 0-56,7 L/min (0–15 USgpm) 20 – 0-75,7 L/min (0–20 USgpm) 25 – 0-94,6 L/min (0–25 USgpm) 30 – 0-113,5 L/min (0–30 USgpm) 35 – 0-132,4 L/min (0–35 USgpm) 40 – 0-151,4 L/min (0–40 USgpm) 45 – 0-170,3 L/min (0–45 USgpm)

82 cm3/min (5 in3/min maximum 210 bar (3000 psi) -40° to 120°C (-40° to 248°F) D – Lever (10 position detent)* L– Lever (friction lock)* K– Knob (non-locking) C–16–2 All general purpose hydraulic fluids such as: MIL-H-5606, SAE 10, SAE 20 etc. Cleanliness code 18/16/13 Aluminum 0,79 kg (1.74 lbs) 565810 (Buna-N), 889609 (Viton®)

Viton is a registered trademark of E.I. DuPont

Description

Pressure Drop Curves

This is a 2 way 2 position manually operated semi rotary restrictor screw in cartridge valve. This can be used in conjunction with a compensator to give an increase in flow in proportion to the movement of the lever.

Cartridge only

@ 5,5 bar (80 psi) pressure drop

Flow - L/min (21,8 cSt oil @ 49°C) 20 9

A

8 Knob lever position

40

60 B

80 C

100 D

E

120

140

F

G

160

180

H

7 6 5 4 3 2 1 0

4

8

12

16

20

24

28

32

36

40

44

Flow - USgpm (105 SUS oil @ 20°F) Rated flow (See model code position 6) A - 10 C - 20 E - 30 B - 15 D - 25 F - 35

G - 40 H - 45

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-330.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

MRV2-16 - Flow Restrictor Valve Semi-rotary Up to 170 L/min (45 USgpm) • 210 bar (3000 psi)

MRV2 – 16

Model Code

1 1 Function

(V) – * – ** – ** – 00

2

3

4

5

6

7

5 Port Size

MRV2 - Manual rotary valve

2 Size 16 - 16 size

3 Seal Material Blank - Buna-N V- Viton®

4 Adjustment O - Cartridge only D - Lever (10 position detent)* L - Lever (friction lock)* K - Knob (non-locking)

Code

6 Max Flow Ranges

Port Size

Housing Number

0 Cartridge only 6B 3/4” BSPP 12T SAE 12 4G 1/2” BSPP 6G 3/4” BSPP 10H SAE 10 12H SAE 12 See section J for housing details.

Aluminium Light duty

Aluminium Fatigue rated

02-175463 566149 – – – –

– – 876716 876718 876717 566113

10 - 0-37,8 L/min (0-10 USgpm) 15 - 0-56,7 L/min (0-15 USgpm) 20 - 0-75,7 L/min (0-20 USgpm) 25 - 0-94,6 L/min (0-25 USgpm) 30 - 0-113,5 L/min (0-30 USgpm) 35 - 0-132,4 L/min (0-35 USgpm) 40 - 0-151,4 L/min (0-40 USgpm) 45 - 0-170,3 L/min (0-45 USgpm)

7 Special Features 00 - None (Only required if valve has special features, omit if ("00")

*Light duty housings only.

Dimensions

Torque cartridge in aluminum housing 108-122 Nm (80-90 ft lbs)

mm (inch) Cartridge Only Basic Code MRV2-16

Installation Drawing

H

-16-K Knob Operated MRV2-16-K Knob Operated

MRV2-16-D/L Models

MRV2-16-D/L Models

58,0 (2.28)

X 6,0 (2.40)

6,0 (2.40)

ed

46,0 (1.81) 38,1 (1.50) hex 2 1

1.312"-12 Thd. 44,4 (1.75) Ø28,55 (1.124)

1

Locating pin hole

38,1 (1.50) hex

1.312"-12 Thd. Ø3,45-3,50 0 (#29 or 0.136+ 0.002) x 4,76 (0.187) in mating housing

Ø28,55 (1.124)

X

76,0 X (3.00)

46.0 (1.81)

X

31.8 (1.25) 76,0 (3.00)

63.5 88.9 (2.50) (3.50) MRV2-16-D Models MRV2-16-D ModelsMRV2-16-L Models MRV2-16-L Models MRV2-16-D/L Models Locating Locating 24,8 24,8 1 Locating Locating pin hole pin hole 58,0 (0.98) (0.98) pin hole pin hole (2.28) 68.28 10.3 38,1 (1.50) hex (0.41) 88.29 (2.688) 1.312"-12 Thd. (3.50 76,0 2 X Ø3,45-3,50 Ø3,45-3,50 (3.00) 0 0 X(#29 or 0.136+ 0.002) (#29 or 0.136+ 0.002) x 4,76 (0.187) x 4,76 (0.187) in mating housing in mating housing Ø28,55 (1.124)

MRV2-16-D Models 24,8 (0.98)

58,0 (2.28)

MRV2-16-L Models Locating pin hole

28.4 (1.12)

2

2 x 8.74 (0.344)

1

WARNING Aluminum housings can be used for pressures up to 210 bar (3000 psi). Steel housings must be used for operating pressures above 210 bar (3000 psi).



Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-331.A

2CR80 - Flow Restrictor Valve Needle with free reverse flow check 80 L/min (20 USgpm) • 350 bar (5000 psi)

1

2

Operation

Features

Rotation of the adjustment screw varies the valve opening to give a flow path approximately proportional to the turns of the screw. The check valve allows free flow in one direction.

All steel construction with hardened and ground adjustment needle. Cartridge construction for versatility in applications. Sealed adjuster for leak-free adjustment..

Performance Data

Sectional View

Ratings and Specifications

Performance data is typical with fluid at 40 cSt and 40°C Maximum pressure Rated inlet flow Temperature range Cavity Mounting position Torque cartridge into cavity Fluids Filtration Nominal viscosity Standard housing material Cartridge material Weight cartridge only Seal kit

2

350 bar (5000 psi) 80 L/min (20 USgpm) -30° to 120°C (-22° to 248°F)) A7447 (See Section M) Unrestricted 75 Nm (55 lbs ft) All general purpose hydraulic fluids such as: MIL-H-5606, SAE 10, SAE 20 etc. BS5540/4 Class 18/16/13 (25 micron nominal) 32 cSt Standard aluminum (up to 210 bar), add suffix "377" for steel option Working parts hardened and ground steel. Zinc plated body 0,2 kg (0.4 lbs) SK578 (Nitrile), SK578V (Viton®)

Viton is a registered trademark of E.I. DuPont

H 1

Flow - L/min 20 40 60

80

725 580 435

60 50

Free flow Adjuster fully in

40 30

290

20

145

10

0 0

0 5.3 10.6 15.9 21.2 Flow - US gpm

Pressure - psi

0

Pressure - bar

870 Pressure - psi

The cartridge restrictor valve range can be set and locked to restrict flow in one direction. A typical use is the speed control of cylinder or other actuators. The free flow check allows for meter-in or meter-out actuator control.

2320 2030 1740 1450 1160 870

Flow - L/min 20 40 60

0

80

4 3

Pressure drop per turn from 5 closed

160 140 120 100 80 60

6

580 290 0

40 20 8 0 5.3 10.6 15.9 21.2 Flow - US gpm

Pressure - bar

Pressure Drop

Description

7

0

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-340.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

2CR80 - Flow Restrictor Valve Needle with free reverse flow check 80 L/min (20 USgpm) • 350 bar (5000 psi)

Model Code

2CR8* – P 1

1 Function 2CR80 - Cartridge only 2CR85 - Cartridge and body

2 Adjustment P - Leakproof screw R - Handknob

4W – S

2

3

4 4 Seals

3 Port Size Code

Port Size

Housing Number

0 4W 8T

Cartridge only 1/2” BSPP 1/2” SAE

Aluminium

Steel

B7418 B10712

B13663 B11565

S - Nitrile (for use with most industrial hydraulic oils) SV - Viton® (for high temperature & most special fluid applications)

See page H-6 for dimensions.

Dimensions

mm (inch) Cartridge Only Basic Code 2CR80

Complete Valve Basic Code 2CR85

H

4.0 A/F

9.0 (0.35) 31.0 (1.22) 32 A/F

124.5 (4.09) max

2

28.5 (1.12) 75.0 (2.95)

57.0 (2.24)

1

25.5 (1.00) 53.0 (2.09) 47.0 (1.85)

63.5 (2.50)

2 holes Ø11.0 (0.43) thro’

19.0 (0.75) 38.1 (1.50)

M.27.0 x 2.0 thread

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-341.A

NV1-8 - Flow Restrictor Valve Needle 45 L/min (12 USgpm) • 280 Bar (4000 psi)

Operation

Dynamic Signal (PFRD)

1

2

Sectional View

Features

This needle valve is a variable orifice used to create a pressure drop when flow passes from port 1 to port 2 or port 2 to 1. Clockwise rotation of the adjust screw decreases

the orifice size to completely closed and anti-clockwise increases the orifice. The setting can be locked using the lock nut on the adjust screw.

Hardened and ground working components. Cartridge construction for maximum mounting flexibility.

Performance Data Ratings and Specifications

2

Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F) Typical application pressure (all ports) 350 bar (5000 psi) steel housing 210 bar (3000 psi) aluminum housing Cartridge fatigue pressure (infinite life) 280 bar (4000 psi) Rated flow 45 L/min (12 USgpm) Internal leakage 5 drops/min. maximum @ 350 bar (5000 psi) Temperature range -40° to 120°C (-40° to 248°F) Cavity C–8–2 Fluids All general purpose hydraulic fluids such as: MIL–H–5606, SAE 10, SAE 20, etc. Filtration Cleanliness code 18/16/13 Standard housing materials Aluminum or steel Weight cartridge only 0,07 kg. (0.15 lbs.) Seal Kits 02-165875 Buna–N 02-165877 Viton® Viton is a registered trademark of E.I. DuPont

H 1

Description

Pressure Drop

This is a manually adjusted cartridge type needle valve. With fine control it is ideal for none compensated speed control of actuators or as a control orifice in conjuntion with a pressure compensator. Total shut off can be achieved allowing the valve to be used as a shut off valve.

Cartridge only

200

0

Flow - L/min (21,8 cSt oil @ 49°C) 20 30 40 10

150 8

100

4

50 0

Pressure drop - bar

Pressure drop - psi

12

0 0

5

10

12

Flow - USgpm (105 SUS oil @ 120°F) Fully open port 1 to port 2 or port 2 to port 1 Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-342.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

NV1-8 - Flow Restrictor Valve Needle 45 L/min (12 USgpm) • 280 Bar (4000 psi)

Model Code

NV1 – 8 – (V) – * – (*) – ** – 00 1

1 Function NV1 - Needle valve

2 Size 8 - 8 size

3 Seal Material Blank - Buna-N V- Viton®

4 Style S - C - K -

2

3

5

4

6

7 7 Special Features

6 Port Size Code

Port Size

Housing Number

0 4T 6T 8T 2G

Cartridge only SAE 4 SAE 6 SAE 8 1/4” BSPP

Aluminium Fatigue duty

Steel Fatigue rated

02–160730 02–160731 02–160732 02–160727

02-160736 02-160737 02–160738 02-160733

02–160728

02-160734

3G 3/8” BSPP See section J for housing details.

00 - None (Only required if valve has special features, omit if ("00")

Screw Cap Knob

5 Valve Housing Material Omit - Cartridge only S - Steel A - Aluminum

H Dimensions

mm (inch) Cartridge Only Basic Code NV1-8

Torque cartridge in aluminum or steel housing 34-41 Nm (25-30 ft lbs)

"C" Adjustment

12,7 (.50) hex

33,3 (1.31)

0.750"–16 Thd.

22,1 (0.87) hex

27,8 (1.09)

2

WARNING Aluminum housings can be used for pressures up to 210 bar (3000 psi). Steel housings must be used for operating pressures above 210 bar (3000 psi).



1 Ø12,62 (0.497)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-343.A

NV1-10 - Flow Restrictor Valve Needle 45 L/min (12 USgpm) • 210 bar (3000 psi)

1

2

Sectional View

Operation

Features

This needle valve is a variable orifice used to create a pressure drop when flow passes from port 1 to 2 or port 2 to 1. Clockwise rotation of the adjust screw de-creases the orifice size to completely closed and anti-clockwise increases the orifice. The setting can be locked using the lock nut on the adjust screw

Hardened and ground working components. Cartridge construction for maximum mounting flexibility.

Performance Data Ratings and Specifications

Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F) Typical application pressure (all ports) 210 bar (3000 psi) Cartridge fatigue pressure (infinite life) 210 bar (3000 psi) Rated flow 45 L/min (12 USgpm) Internal leakage 5 drops/min maximum @ 210 bar (3000 psi) Temperature range -40° to 120°C (-40° to 248°F) Cavity C–10–2 Fluids All general purpose hydraulic fluids such as: MIL-H-5606, SAE 10, SAE 20 etc. Filtration Cleanliness code 18/16/13 Standard housing material Aluminum Weight cartridge only 0,11 kg. (0.24 lbs) Seal kit 565806 (Buna-N) 889627 (Viton®)

H 2

Viton is a registered trademark of E.I. DuPont

1 Description

Pressure Drop

This is a manually adjusted cartridge type needle valve. With fine control it is ideal for none compensated speed control of actuators or as a control orifice in conjunction with a pressure compensator Total shut off can be achieved allowing the valve to be used as a shut of valve.

Cartridge only

Flow - L/min (21,8 cSt oil @ 49°C) 10 15 20

25 30 35

40

45

70

5

60

4

50

3

40 30

2

20

1

10 0

Pressure drop - bar

Pressure drop - psi

5

0

2

4

6

8

10

12

0

Flow - USgpm (105 SUS oil @ 120°F) Fully open port 1 to port 2 or port 2 to port 1 Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-350.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

NV1-10 - Flow Restrictor Valve Needle 45 L/min (12 USgpm) • 210 bar (3000 psi)

NV1 – 10

Model Code

1 1 Function

(V) – * – ** – 00

2

3

4

5

6

5 Port Size

NV1 - Needle valve

Code

6 Special Features

Port Size

0 Cartridge only 3B 3/8" BSPP 6T SAE 6 2G 1/4" BSPP 3G 3/8" BSPP 6H SAE 6 3G SAE 8 See section J for housing details.

2 Size 10 - 10 size

3 Seal Material Blank - Buna-N V- Viton®

4 Adjustment K - Knob (black) R - Knob (red)

Housing Number

Aluminium Light duty

Aluminium Fatigue rated

02–175462 566151 – – – –

– – 876702 876703 876700 876701

00 - None (Only required if valve has special features, omit if ("00")

Torque cartridge in aluminum housing 47-54 Nm (35-40 ft lbs)

Dimensions

mm (inch) Cartridge Only Basic Code NV1-10

Installation Drawing

H 25.4 (1.00)

44.5 (1.75)

Ø42,0 (1.65)

63.5 (2.50)

9.1 (0.75) 2

44.5 (1.75)

1 9.5 (0.37)

43,0 (1.69)

44.46 (1.750) 63.5 (2.50)

2 x 7.14 (0.281)

1

25,4 (1.00) hex 0.875" -14 Thd.

31,7 (1.25)

2 1

Ø15,80 (0.622)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-351.A

NV1-16 - Flow Restrictor Valve Needle 151 L/min (40 USgpm) • 210 bar (3000 psi)

1

2

Sectional View

Operation

Features

This needle valve is nonpressure compensated. Flow is controlled in the direction from port 2 to port 1, from full flow to tight shut-off, by turning the adjustment feature clockwise. The flow from port 1 to port 2 will be restricted.

Hardened and ground working components. Cartridge construction for maximum mounting flexibility.

Performance Data Ratings and Specifications

Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F) Typical application pressure (all ports) 210 bar (3000 psi) Cartridge fatigue pressure (infinite life) 210 bar (3000 psi) Rated flow 151 L/min (40 USgpm) Internal leakage 5 drops/min maximum @ 210 bar (3000 psi) Temperature range -40° to 120°C (-40° to 248°F) Cavity C–16–2 Fluids All general purpose hydraulic fluids such as: MIL-H-5606, SAE 10, SAE 20 etc. Filtration Cleanliness code 18/16/13 Standard housing material Aluminum Weight cartridge only 0,34 kg. (0.76 lbs) Seal kit 565810 (Buna-N), 889609 (Viton®) Viton is a registered trademark of E.I. DuPont

2

H 1 Description

Pressure Drop Curves

This is a manually adjusted cartridge type needle valve. With fine control it is ideal for none compensated speed control of actuators or as a control orifice in conjunction with a pressure compensator Total shut off can be achieved allowing the valve to be used as a shut of valve.

Cartridge only

0

Flow - L/min (21,8 cSt oil @ 49°C) 20

40

60

80

100

120

140

Pressure drop - psi

60

4

50 3

40 30

2

20 1

10 0

Pressure drop - bar

5

70

0

10

20

30

40

Flow - USgpm (105 SUS oil @ 20°F) Full open port 2 to port 1 Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-360.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

NV1-16 - Flow Restrictor Valve Needle 151 L/min (40 USgpm) • 210 bar (3000 psi)

NV1 – 16

Model Code

1 1 Function

(V) – * – ** – 00

2

3

4

5

6

5 Port Size

NV1 - Needle valve

Code

6 Special Features

Port Size

Housing Number

0 Cartridge only 6B 3/4" BSPP 12T SAE 12 4G 1/2" BSPP 6G 3/4" BSPP 10H SAE 10 12G SAE 12 See section J for housing details.

2 Size 16 - 16 size

3 Seal Material Blank - Buna-N V- Viton®

4 Adjustment K - Knob (black) R - Knob (red)

Aluminium Light duty

Aluminium Fatigue rated

02–175463 566149 – – – –

– – 876716 876718 876717 566113

00 - None (Only required if valve has special features, omit if ("00")

Torque cartridge in aluminum housing 108-122 Nm (80-90 ft lbs)

Dimensions

mm (inch)

H

Installation Drawing

Cartridge Only Basic Code NV1-16

31.8 (1.25)

61.6 (2.40)

Ø61,0 (2.40)

2

63.5 88.9 (2.50) (3.50)

61,0 (2.40)

1

38,1 (1.50) hex 1.312"?-12 Thd. 44,4 (1.75)

10.3 (0.41)

68.28 (2.688) 88.29 (3.50)

28.4 (1.12)

2 x 8.74 (0.344)

1

2 1 Ø28,55 (1.124)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-361.A

NV1-20 - Flow Restrictor Valve Needle 265 L/min (70 USgpm) • 210 bar (3000 psi)

1

2

Operation

Features

This needle valve is nonpressure compensated. Flow is controlled in the direction from port 2 to port 1, from full flow to tight shut-off, by turning the adjustment feature clockwise. The flow from port 1 to port 2 will be restricted.

Hardened and ground working components. Cartridge construction for maximum mounting flexibility.

Performance Data

Sectional View

Ratings and Specifications

Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F) Typical application pressure (all ports) 210 bar (3000 psi) Cartridge fatigue pressure (infinite life) 210 bar (3000 psi) Rated flow 265 L/min (70 USgpm) Internal leakage 5 drops/min maximum @ 210 bar (3000 psi) Temperature range -40° to 120°C (-40° to 248°F) Cavity C–20–2 Fluids All general purpose hydraulic fluids such as: MIL-H-5606, SAE 10, SAE 20 etc. Filtration Cleanliness code 18/16/13 Standard housing material Aluminum Weight cartridge only 0,59 kg. (1.3 lbs) Seal kit 889615 (Buna-N), 889619 (Viton®) Viton is a registered trademark of E.I. DuPont

2

H 1 Description

Pressure Drop Curves

This is a manually adjusted cartridge type needle valve. With fine control it is ideal for none compensated speed control of actuators or as a control orifice in conjunction with a pressure compensator Total shut off can be achieved allowing the valve to be used as a shut of valve.

Cartridge only

Flow - L/min (21,8 cSt oil @ 49°C) 0

40

80

120

160

200

240

5

Pressure drop - psi

60

4

50 40

3

30

2

20 1

10 0

Pressure drop - bar

70

0 0

10

20

30

40

50

60

70

Flow - USgpm (105 SUS oil @ 120°F) Full open port 2 to port 1 Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-370.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

NV1-20 - Flow Restrictor Valve Needle 265 L/min (70 USgpm) • 210 bar (3000 psi)

NV1 – 20

Model Code

1 1 Function

(V) – * – ** – 00

2

3

4

5

6

5 Port Size

NV1 - Needle valve

2 Size 20 - 20 size

3 Seal Material Blank - Buna-N V- Viton®

4 Adjustment Means

6 Special Features

Code

Port Size

Housing Number

0 8B 16T 6G 8G 12H 16H

Cartridge only 1" BSPP SAE 16 3/4" BSPP 1" BSPP SAE 12 SAE 16

Aluminium Light duty

Aluminium Fatigue rated

02-175464 566409 – – – –

– – 876732 876734 876733 876735

K - Knob (black) R - Knob (red)

See section J for housing details.

Dimensions

Torque cartridge in aluminum housing 128-155 Nm (95-115 ft lbs)

mm (inch)

00 - None (Only required if valve has special features, omit if ("00")

H Installation Drawing

Cartridge Only Basic Code NV1-20

Ø60.5 (2.38) 61.9 (2.44)

Ø61,0 (2.40)

41.3 (1.62)

2

76.2 (3.00) 101.6 (4.00)

62,0 (2.44)

2X 8.74 (0.344)

36.0 (1.42)

1

47,6 (1.87) hex 1.625 "-12 Thd.

57,1 (2.25)

10.3 (0.41)

75.4 (2.97) 101.6 (4.00)

2 1 Ø36,47 (1.436)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-371.A

FCV7-10 - Flow Restrictor Valve Needle Up to 45 L/min (12 USgpm) • 210 bar (3000 psi)

Operation 1

2

1

2

Features to completely closed and anticlockwise increases the orifice. The setting can be locked using the lock nut on the adjust screw

This needle valve is a variable orifice used to create a pressure drop when flow passes from port 1 to 2 or port 2 to 1. Clockwise rotation of the adjust screw de-creases the orifice size

Hardened and ground working components. Cartridge construction for maximum mounting flexibility.

Performance Data Ratings and Specifications

Viton is a registered trademark of E.I. DuPont

"NV"

"NVF"

H

Pressure Drop Cartridge only

Description

2400

2400

A

14,4 24,0 33,6 43,2 19,2 28,8 38,4 48,0

B C

D

E F

1200

200 160

1800

120 80

G

600

40

0

0

300

Pressure drop - psi

D

38,4

48,0

E

160 F

1200

120 80

G

600

40

0

0

H

240 180

I

120

J

60 0

200

20 16 12 8 4

0 2 4 6 8 10 12 Flow - USgpm (105 SUS oil @ 120°F)

0

20

Typical Flow Regulation (fullH open) 240 180 Code 120 Option* Curve 60

A B C D E

B C

A

28,8

300

16 I Flow 12 Direction Code J Valve 8 Port: Condition Curve Option

4 2 to 1 Open 0 10 0 0 2 4 1 to 2 Closed 6 8 10 12 20 - USgpm 2(105 to SUS 1 oil @ 120°F) Open Flow

10 40 NVF

Pressure drop - bar

Pressure drop - psi

3000

9,6

Pressure drop - bar

4,8

19,2

1800

Flow - L/min (21,8 cSt oil @ 49°C)

This is a manually adjusted cartridge type needle valve. With fine control it is ideal for none compensated speed control of actuators or as a control orifice in conjunction with a pressure compensator Total shut off can be achieved allowing the valve to be used as a shut of valve.

9,6

3000

Pressure drop - bar

"10,20,40"

1

Pressure drop - psi

"FF" 1

2

Pressure drop - psi

2

Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F) Typical application pressure (all ports) 210 bar (3000 psi) Rated flow 45 L/min (12 USgpm) Temperature range -40° to 120°C (-40° to 248°F) Cavity C–10–2 Fluids All general purpose hydraulic fluids such as: MIL–H–5606, SAE 10, SAE 20, etc. Filtration ISO 4406, class 18/16/13 or cleaner Standard housing materials Aluminum Weight cartridge only 0,11 kg (0.25 lbs.) Flow - L/min (21,8 cSt oil @ 49°C) Seal kits 565806 Buna N 4,8 14,4 24,0 33,6 889627 43,2 Viton®

Pressure drop - bar

Sectional View

1 to 2 1 to 2 2 to 1 1 to 2 Both directions

Closed Open Open Closed Open

Flow Direction Port

Valve Condition

F

20

1 to 2

Open

G

40

1 to 2

Open

H I J

FF FF NV

2 to 1 Open 1 to 2 Open & Closed Both directions Open

*See controlled flow option in model code.

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-380.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

FCV7-10 - Flow Restrictor Valve Needle Up to 45 L/min (12 USgpm) • 210 bar (3000 psi)

Model Code

FCV7 – 10 (V) – * – ** – *** – 00 1

1 Function FCV7 – Flow regulator

2 Size 10 - 10 size

3 Seal Material Blank - Buna-N V- Viton®

4 Style C - Cap K - Knob S - Screw

Dimensions

mm (inch)

2

3

4

5

6

7

5 Port Size

7 Special Features

Code

Port Size

Housing Number

3B 6T 2G 3G 6H 8H

3/8” BSPP SAE 6 1/4” BSPP 3/8” BSPP SAE 6 SAE 8

Aluminium Light duty 02–175462 566151 – – – –

Aluminium Fatigue rated – – 876702 876703 8767008H 876701

00 - None (Only required if valve has special features, omit if ("00")

See section J for housing details.

6 Controlled Flow Option



NV NVF FF 10 20 40

Maximum Flow Range (nominal)

Needle valve Needle valve, fine Needle valve with free reverse flow Flow range, type 10, with free reverse flow Flow range, type 20, with free reverse flow Flow range, type 40, with free reverse flow

0-45 L/min (0-12 USgpm) 0-38 L/min (0-10 USgpm) 0-45 L/min (0-12 USgpm) 0-6,6 L/min (0-1.75 USgpm) 0-14 L/min (0-3.75 USgpm) 0-27 L/min (0-7.25 USgpm)

H

Torque cartridge in aluminum housing to 47–54 Nm (35–40 ft.lbs)

Cartridge Only Basic Code FCV7-10 "K" Adjustment

"C" Adjustment

Ø38,1 (1.50) 5,1 (0.20) max. travel

44 (1.73)

30,2 (1.18)

"S" Adjustment 4,8 (0.18) hex 19,1 (0.75) hex

25,4 (1.00) hex 0.875"-14 Thd. 31,7 (1.25)

2

1

Ø15,82 (0.623)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-381.A

FCV11-12 - Flow Restrictor Valve Needle 114 L/min • 350 bar (5000 psi)

1

2

Operation

Features

This needle valve is a variable orifice used to create a pressure drop when flow passes from port 1 to 2 or port 2 to 1. Clockwise rotation of the adjust screw de-creases the orifice size to completely closed and anticlockwise increases the orifice. The setting can be locked using the lock nut on the adjust screw.

Hardened and ground working components. Cartridge construction for maximum mounting flexibility.

Performance Data

Sectional View

Ratings and Specifications

2

H

Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F) Typical application pressure (all ports) 350 bar (5000 psi) Port “1” to “2” 210 bar (3000 psi) Port “1” to “2” Cartridge fatigue pressure (infinite life) 350 bar (5000 psi) Rated flow 114 L/min (30 USgpm) Internal leakage less than 5 drops/min maximum @ 210 bar (3000 psi) Temperature range -40° to 120°C (-40° to 248°F) Cavity C-12-2 or C-12-2U Fluids All general purpose hydraulic fluids such as MIL-H-5606, SAE 10, SAE 20 etc. Filtration Cleanliness code 18/16/13 Standard housing material Aluminum or steel Weight cartridge only 0,24 kg (0.54 lbs) Seal kit 2–165889 (Buna-N) 02–165888 (Viton®) Viton is a registered trademark of E.I. DuPont

1 Description

Pressure Drop Curves

This is a manually adjusted cartridge type needle valve. With fine control it is ideal for none compensated speed control of actuators or as a control orifice in conjunction with a pressure compensator Total shut off can be achieved allowing the valve to be used as a shut of valve.

Cartridge only

A - Cartridge with C-12-2 valve body, full open B - Cartridge with C-12-2U valve body, full open C - Cartridge only, full open

Flow - L/min (21,8 cSt oil @ 49°C)

20

90

40

60

80

100

6,21 5,52

70

4,83

A

60

4,14

B

50

3,45

C

40

2,5

30

2,0

20

1,0

10

0,5

0

0

5

10

15

20

25

Pressure drop - bar

Pressure drop - psi

80

30

Flow - USgpm (105 SUS @ 120°F) Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-390.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

FCV11-12 - Flow Restrictor Valve Needle 114 L/min • 350 bar (5000 psi)

Model Code

FCV11 – 12 1

1 Function FCV11 - Flow control valve

2 Size 12 - 12 size

3 Seal Material Blank - Buna-N V- Viton®

4 Adjustment S - Screw K - Knob

5 Valve Housing Material

(V) – S –

2

3

* – *** – (U) – NV – 00

4

5

6

7

8

6 Port Size Code

Port Size

Housing Number

C-12-2U Aluminium Fatigue rated 0 Cartridge only 10T(U) SAE 10 02–160641 12T(U) SAE 12 02–160645 4G(U) 1/2" BSPP 02–161116 6G(U) 3/4" BSPP 02–161115 See section J for housing details.

7 Cavity Blank – Cavity without undercut U – Cavity with undercut

C-12-2 Aluminium Fatigue rated

C-12-2U Steel Fatigue rated

C-12-2 Steel Fatigue rated

02–160640 02–160644 02–161118 02–161117

02–169817 02v169790 02–172512 02–162922

02–169744 02–169782 02–172062 02–169665

8 Valve Type NV – Needle Valve

9 Special Features 00 - None (Only required if valve has special features, omit if ("00")

(Adjustable)

Blank - No body A - Aluminum S - Steel

Dimensions

mm (inch)

9

Torque cartridge in housing A - 81–95 Nm (60–70 ft lbs) S - 102–115 Nm (75–85 ft lbs)

H Cartridge Only Basic Code FCV11-12

Installation Drawing (Steel) 20.7 (0.81)

"S" Adjustment 3,2 (0.12) hex

28.7 (1.13)

40,0 (1.60)

2 63.5 88.9 (2.500) (3.50)

31,8 (1.25) hex

2 X Ø 10.31 (0.46) 1

1.063"–12 Thd.

12.7 (0.50)

44,6 (1.80)

88.9 (3.50)

63.5 (2.500)

25.4 (1.00) 50.8 (2.00)

2 WARNING

1

Ø23,75 (0.935)

• Aluminum housings can be used for pressures up to 210 bar (3000 psi). Steel housings must be used for operating pressures above 210 bar (3000 psi).

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-391.A

FCV6-16 - Flow Restrictor Valve Needle 208 L/min (55 USgpm) • 210 bar (3000 psi)

Operation 1

2

Features

This needle valve is a variable orifice used to create a pressure drop when flow passes from port 1 to 2 or port 2 to 1.

Clockwise rotation of the adjust screw de-creases the orifice size to completely closed and anticlockwise increases the orifice. The setting can be locked using the lock nut on the adjust screw.

Hardened and ground working components. Cartridge construction for maximum mounting flexibility.

Sectional View Performance Data Ratings and Specifications

2

Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F) Typical application pressure (all ports) 210 bar (3000 psi) Cartridge fatigue pressure (infinite life) 210 bar (3000 psi) Rated flow 208 L/min (55 USgpm) Internal leakage Port 2 to 1; <5 drops/min maximum @ 210 bar (3000 psi) Temperature range -40° to 120°C (-40° to 248°F) Cavity C–16–2 Fluids All general purpose hydraulic fluids such as: MIL-H-5606, SAE 10, SAE 20 etc. Filtration Cleanliness code 18/16/13 Standard housing material Aluminum Weight cartridge only 0,37 kg (0.81 lbs) Seal kit 889631 (Buna-N) 889635 (Viton®) Viton is a registered trademark of E.I. DuPont

H 1 Description

Pressure Drop

This is a manually adjusted cartridge type needle valve. With fine control it is ideal for none compensated speed control of actuators or as a control orifice in conjunction with a pressure compensator Total shut off can be achieved allowing the valve to be used as a shut of valve.

Cartridge only

Flow - L/min (21,8 cSt oil @ 49°C) 40

80

120

160

200

7

Pressure drop - psi

90

6

80 70

5

60

4

50 3

40 30

2

20

1

10 0

Pressure drop - bar

0 100

0

10

20

30

40

50

60

Flow - USgpm (105 SUS @ 120°F)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-400.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

FCV6-16 - Flow Restrictor Valve Needle 208 L/min (55 USgpm) • 210 bar (3000 psi)

FCV6 – 16

Model Code

1 1 Function

(V) – * – *** – NV – 00

2

3

4

5

6

7

5 Port Size

FCV6 - Needle valve

Code

6 Controlled Flow Option

Port Size

0 Cartridge only 6B 3/4" BSPP 12T SAE 12 4G 1/2" BSPP 6G 3/4” BSPP 10H SAE 10 12H SAE 12 See section J for housing details.

2 Size 16 - 16 size

3 Seal Material Blank - Buna-N V- Viton®

4 Adjustment C - Cap K – Knob S – Screw

NV – Needle valve

Housing Number

Aluminium Light duty

Aluminium Fatigue rated

02–175463 566149 – – – –

– – 876716 876718 876717 566113

7 Special Features 00 - None (Only required if valve has special features, omit if ("00")

Torque cartridge in aluminum housing 108-122 Nm (80-90 ft lbs)

Dimensions

mm (inch)

H

Installation Drawing

Cartridge Only Basic Code FCV6-16

"S" Adjustment 4,8 (0.18) hex

"C" Adjustment 19,1 (0.75) hex

"K" Adjustment Ø38,1 (1.50)

51,0 (2.00)

59.2 (2.33) 28.4 (1.12)

38,1 (1.5) hex

51,0 (2.00)

59,0 (2.32)

63.5 (2.50)

2

88.9 (3.50)

2X 8.74 (.344) 1

1.312" -12 Thd. 44,7 (1.76)

10.3 (0.41)

68.28 (2.688) 88.9 (3.50)

31.8 (1.25)

2 1

Ø28,55 (1.124)

WARNING Aluminum housings • can be used for pressures up to 210 bar (3000 psi). Steel housings must be used for operating pressures above 210 bar (3000 psi). Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-401.A

PCS3-10 - Pressure Compensator Restrictive 38 L/min (10 USgpm) • 210 bar (3000 psi)

3

2

1

Sectional View

Operation

Features

This valve, when used with either a fixed or variable orifice between port 1 and port 3, maintains a constant flow. This is based on what ever pressure differential is chosen. Flow out of port 2, regardless of pressure, changes downstream on port 2.

Hardened and ground and honed working components. Cartridge construction for maximum mounting flexibility.

Performance Data Ratings and Specifications

3

2

H

Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49° C (120° F) Typical application pressure (all ports) 210 bar (3000 psi) Cartridge fatigue pressure (infinite life) 210 bar (3000 psi) Rated flow 38 L/min (10 USgpm) Cavity C-10-3 Standard housing materials Customized housings are necessary for close-coupling, the compensator and orifice Temperature range -40° to 120° C (-40° to 248° F) Fluids All general purpose hydraulics fluids such as: MIL-H-5606, SAE 10, SAE 20 etc Filtration Cleanliness code 18/16/13 Weight cartridge only 0,12 kg (0.26 lbs) Seal kit 565812 (Buna-N), 889611 (Viton®) Viton is a registered trademark of E.I. DuPont

1 Description

Performance Characteristics

This is a restrictive style compensator suitable for use with a separate needle valve or orifice to provide a pressure compensated flow while the excess oil passes over a relief valve or closes down the compensator on a pump. This, when used in a manifold, is ideal for motor or cylinder speed control either meter in or meter out.

Cartridge only

0.200 0.175

0

4

8

12 16

20

24

28

32

36

4

A

0.150

5

B

0.125

C

0.100 0.075

3 2

0.050

1

0.025 0

0 0

Approx. orifice diameter - mm

Approx. orifice diameter - inches

Controlled flow - L/min (21,8 cSt oil @ 49°C)

1 2 3 4 5 6 7 8 9 10 Controlled flow - USgpm (105 SUS oil @ 120°F)

A - 2,8 bar (40 psi) (control P) B - 5,5 bar (80 psi) (control P) C - 11,0 bar (160 psi) (control P) Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-410.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

PCS3-10 - Pressure Compensator Restrictive 38 L/min (10 USgpm) • 210 bar (3000 psi)

PCS3 – 10 (V) –

Model Code 1

Function

PCS3 - Pressure compensator restrictive type

2

Size

1

2

3

Seal Material

3

4

Port Size

0 - Cartridge only (Customized housings are necessary for close-coupling, compensator and orifice)

Dimensions mm (inch)

5

6

7

5 Spool Seals Blank - No seal on spool S - Seal on spool

Blank - Buna-N V - Viton®

4

10 - 10 size

* – (S) – *** – 00

(For load holding applications where leakage from port 1 to 2 could cause cylinder drift, use of seal will increase hysteresis)

6

Pressure Differential (Nominal)

40 - 2,8 bar (40 psi) 60 - 4,1 bar (60 psi) 80 - 5,5 bar (80 psi) 160 - 11,0 bar (160 psi)

7

Special Features

00 - None (Only required if valve has special features, omit if ("00")

Torque into aluminum housing to 47-54 Nm (35-40 ft lbs)

Cartridge Only Basic Code PCS3-10

H

19,0 (0.75)

25,4 (1.00) hex

0.875 -14 Thd. 3

46,0 (1.81)

2

1

15,80 (0.622) 17,40 (0.685)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-411.A

PCS13-10 - Pressure Compensator Restrictive 38 L/min (10 USgpm) • 350 bar (5000 psi)

3

2

1

Sectional View

Operation

Features

This valve, when used with either a fixed or variable orifice between port 1 and port 3, maintains a constant flow. This is based on what ever pressure differential is chosen. Flow out of port 2, regardless of pressure, changes downstream on port 2.

Hardened and ground and honed working components. Cartridge construction for maximum mounting flexibility. Working pressure 350 bar.

Performance Data Ratings and Specifications

3

2

H 1

Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F) Typical application pressure (all ports) 350 bar (5000 psi) Cartridge fatigue pressure (infinite life) 350 bar (5000 psi) Rated flow 38 L/min (10 USgpm) Cavity C-10-3 Standard housing materials Customized housings are necessary for close-coupling, the compensator and orifice Temperature range -40° to 120°C (-40° to 248°F) Fluids All general purpose hydraulic fluids such as MIL-H-5606, SAE 10, SAE 20, etc. Filtration Cleanliness code 8/16/13 Weight cartridge only 0,12 kg (0.26 lbs) Seal kit 5565818 (Buna-N) 889611 (Viton®) Viton is a registered trademark of E.I. DuPont

Description

Performance Characteristics

This is a high pressure restrictive style compensator suitable for use with a separate needle valve or orifice to provide a pressure compensated flow while the excess oil passes over a relief valve or closes down the compensator on a pump. This, when used in a manifold, is ideal for motor or cylinder speed control either meter in or meter out.

Cartridge only

0.200 0.175

0

4

8

12 16

20

24

28

32

36

4

A

0.150

5

B

0.125

C

0.100 0.075

3 2

0.050

1

0.025 0

0 0

Approx. orifice diameter - mm

Approx. orifice diameter - inches

Controlled flow - L/min (21,8 cSt oil @ 49°C)

1 2 3 4 5 6 7 8 9 10 Controlled flow - USgpm (105 SUS oil @ 120°F)

A - 2,8 bar (40 psi) (control B - 5,5 bar (80 psi) (control C - 11,0 bar (160 psi) (control

P) P) P)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-420.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

PCS13-10 - Pressure Compensator Restrictive 38 L/min (10 USgpm) • 350 bar (5000 psi)



PCS13 – 10

Model Code



1 1

Function

PCS13 - Pressure compensator restrictive type

2

Size

2

(V) –

* – (S) – *** – 00

3

4

4 Port Size 0 - Cartridge only

5

(Customized housings are necessary for close-coupling, compensator and orifice)

10 - 10 Size

3

5

Seals

Blank - Buna-N V- Viton®

6

7

Spool Seals

Blank - No seal on spool S - Seal on spool. (For load holding applications were leakage from port 1 to 2 could cause cylinder drift, use of seal will increase hysteresis)

6

Pressure Differential

40 - 2,8 bar (40 psi) 80 - 5,5 bar (80 psi) 160 - 11,0 bar (160 psi)

7

Special Features

00 - None (Only required if valve has special features, omitted if “00.”)

Torque into aluminum housing to 47-54 Nm (35-40 ft. lbs)

Dimensions mm (inch)

Torque into steel housing to 68-75 Nm (50-55 ft. lbs)

Cartridge Only Basic Code PCS13-10

H 25,65 (1.010)

25.4" (1.00) hex

7/8" - 14 Unf - 2A Thd.

3 46,0 (1.81) 2

1 15.78 - 15.82 (0.621 - 0.623) 17.38 - 17.42 (0.684 - 0.686)

WARNING Aluminum housings can be used for • pressures up to 210 bar (3000 psi). Steel housings must be used for operating pressures above 210 bar (3000 psi).

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-421.A

PCS3-12 - Pressure Compensator Restrictive 58 L/min (15 USgpm) • 240 bar (3500 psi)

3

2

1

Sectional View

Operation

Features

This valve, when used with either a fixed or variable orifice between port 1 and port 3, maintains a constant flow. This is based on what ever pressure differential is chosen. Flow out of port 2, regardless of pressure, changes downstream on port 2.

Hardened and ground and honed working components. Cartridge construction for maximum mounting flexibility.

Performance Data Ratings and Specifications

Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49° C (120° F) Typical application pressure (all ports) 240 bar (3500 psi) Cartridge fatigue pressure (infinite life) 240 bar (3500 psi) Rated flow 58 L/min (15 USgpm) Cavity C-12-3 Standard housing materials Customized housings are necessary for close-coupling, the compensator and orifice Temperature range -40° to 120° C (-40° to 248° F) Fluids All general purpose hydraulics fluids such as MIL-H-5606, SAE 10, SAE 20 etc Filtration Cleanliness code 18/16/13 Weight cartridge only 0,30 kg (0.55 lbs) Seal kit 9900333-000 (Buna-N 9900334-000 (Viton®)

3

Viton is a registered trademark of E.I. DuPont

2

1 Description

Performance Characteristics

This is a restrictive style compensator suitable for use with a separate needle valve or orifice to provide a pressure compensated flow while the excess oil passes over a relief valve or closes down the compensator on a pump. This, when used in a manifold, is ideal for motor or cylinder speed control either meter in or meter out.

Cartridge only 0.300 External orifice diameter (inch)

H

A B

0.250

C

0.200 0.150 0.100 0.050 0.000

0

A - 2,8 bar (40 psi) (control B - 5,5 bar (80 psi) (control C - 11,0 bar (160 psi) (control

5

Flow (gpm)

10

15

P) P) P)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-430.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

PCS3-12 - Pressure Compensator Restrictive 58 L/min (15 USgpm) • 240 bar (3500 psi)

PCS3 – 12 (V) –

Model Code

1

1 Function

3

DCS3 - Pressure compensator restrictive type

2

Size

3

4

Seal Material

Port Size

0 - Cartridge only (Customized housings are necessary for close-coupling, compensator and orifice)

Dimensions mm (inch)

5 5

Blank - Buna-N V - Viton®

4

12 - 12 size

2

* – (S) – *** – 00 6

7

Spool Seals

Blank - No seal on spool S - Seal on spool (For load holding applications where leakage from port 1 to 2 could cause cylinder drift, use of seal will increase hysteresis)

6

Pressure Differential (Nominal)

40 - 2,8 bar (40 psi) 80 - 5,5 bar (80 psi) 120 - 8,3 bar (120 psi)

7

Special Features

00 - None (Only required if valve has special features, omit if "00".)

Torque into aluminum housing to 81-95 Nm (60-70 ft lbs)

H

Cartridge Only Basic Code PCS3-12

31,7 (1.25) HEX 33,3 (1.31) 1 1/16-12 UNF 2A THREAD

68,6 (2.70)

.873 ± .001 .935 ± .001

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-431.A

PCS13-12 - Pressure Compensator Restrictive 58 L/min (15 USgpm) • 350 bar (5000 psi)

3

2

1

Sectional View

Operation

Features

This valve, when used with either a fixed or variable orifice between port 1 and port 3, maintains a constant flow. This is based on what ever pressure differential is chosen. Flow out of port 2, regardless of pressure, changes downstream on port 2.

Hardened and ground and honed working components. Cartridge construction for maximum mounting flexibility. Working pressure 350 bar.

Performance Data Ratings and Specifications

3

Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F) Typical application pressure (all ports) 350 bar (5000 psi) Cartridge fatigue pressure (infinite life) 350 bar (5000 psi) Rated flow 58 L/min (15 USgpm) Cavity C-12-3 Standard housing materials Customized housings are necessary for close-coupling, the compensator and orifice Temperature range -40° to 120°C (-40° to 248°F) Fluids All general purpose hydraulic fluids such as MIL-H-5606, SAE 10, SAE 20, etc. Filtration Cleanliness code 18/16/13 Weight cartridge only 0,30 kg (.55 lbs) Seal kit 9900333-000 (Buna-N) 9900334-000 (Viton®) Viton is a registered trademark of E.I. DuPont

H

2

1

Description

Performance Characteristics

This is a high pressure restrictive style compensator suitable for use with a separate needle valve or orifice to provide a pressure compensated flow while the excess oil passes over a relief valve or closes down the compensator on a pump. This, when used in a manifold, is ideal for motor or cylinder speed control either meter in or meter out.

Cartridge Only 0.300

EXTERNAL ORIFICE DIAMETER (INCH)

A B

0.250

C

0.200 0.150 0.100 0.050 0.000

0

5

A - 2,8 bar (40 psi) (control B - 5,5 bar (80 psi) (control C - 11,0 bar (160 psi) (control

FLOW (GPM)

10

15

P) P) P)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-440.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

PCS13-12 - Pressure Compensator Restrictive 58 L/min (15 USgpm) • 350 bar (5000 psi)



PCS13 – 12

Model Code



1 1

Function

PCS13 - Pressure compensator restrictive type

2

Size

2

(V) – 3

* – 4

5 5

4 Port Size 0 - Cartridge only

(Customized housings are necessary for close-coupling, compensator and orifice)

12 - 12 Size

3

(S) – *** – 00 6

7

Spool Seals

Blank - No seal on spool S - Seal on spool. (For load holding applications were leakage from port 1 to 2 could cause cylinder drift, use of seal will increase hysteresis)

6

Pressure Differential

40 - 2,8 bar (40 psi) 80 - 5,5 bar (80 psi) 120 - 8,3 bar (120psi) 160 - 11,0 bar (160 psi)

7

Special Features

00 - None (Only required if valve has special features, omitted if “00.”)

Seals

Blank - Buna-N V - Viton®

Torque into aluminum housing to 81-95 Nm (60-70 ft. lbs)

Dimensions mm (inch)

Torque into steel housing to 102-115 Nm (75-85 ft. lbs)

Cartridge Only Basic Code PCS13-12

H 22,86 (0.900)

31,75 (1.25) hex

1 1/16 - 12 Un - 2A Thd.

68,48 (2.696)

3

2

1 22,15 - 22,19 (0.872 - 0.874) 22,73 - 23,77 (0.934 - 0.936)

WARNING Aluminum housings • can be used for pressures up to 210 bar (3000 psi). Steel housings must be used for operating pressures above 210 bar (3000 psi).

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-441.A

PCS3-16 - Pressure Compensator Restrictive 114 L/min (30 USgpm) • 210 bar (3000 psi) Operation

3

2

Features pressure differential is chosen. Flow out of port 2, regardless of pressure, changes downstream on port 2.

This valve, when used with either a fixed or variable orifice between port 1 and port 3, maintains a constant flow. This is based on what ever

Hardened and ground and honed working components. Cartridge construction for maximum mounting flexibility. Working pressure 350 bar.

1

Performance Data

Sectional View

Ratings and Specifications

3

2

Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49° C (120° F) Typical application pressure (all ports) 210 bar (3000 psi) Cartridge fatigue pressure (infinite life) 210 bar (3000 psi) Rated flow 114 L/min (30 USgpm) Cavity C-16-3 Standard housing materials Customized housings are necessary for close-coupling, the compensator and orifice. Temperature range -40° to 120° C (-40° to 248° F) Fluids All general purpose hydraulics fluids such as: MIL-H-5606, SAE 10, SAE 20 etc Filtration Cleanliness code 18/16/13 Weight cartridge only 0,38 kg (0.84 lbs) Seal kit 565811 (Buna-N) 889610 (Viton®) Viton is a registered trademark of E.I. DuPont

H 1

Description

Performance Characteristics

This is a restrictive style compensator suitable for use with a separate needle valve or orifice to provide a pressure compensated flow while the excess oil passes over a relief valve or closes down the compensator on a pump. This, when used in a manifold, is ideal for motor or cylinder speed control either meter in or meter out.

Cartridge only

12

24

36

0.400 0.350

48

60

72

84

96

108 10

A

0.300

8

B

0.250

6

C

0.200 0.150

4

0.100 0.050 0

2 0

3

6

9

12

15

18

21

24

27

30

0

Approx. orifice diameter - mm

Approx. orifice diameter - inches

Controlled flow - L/min (21,8 cSt oil @ 49° C) 0

Controlled flow - USgpm (105 SUS oil @ 120° F)

A - 2,8 bar (40 psi) (control P) B - 5,5 bar (80 psi) (control P) C - 11,0 bar (160 psi) (control P) Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-450.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

PCS3-16 - Pressure Compensator Restrictive 114 L/min (30 USgpm) • 210 bar (3000 psi)

PCS3 – 16 (V) –

Model Code

1

1 Function

3

PCS3 - Pressure compensator restrictive type

2

3

4

Port Size

0 - Cartridge only (Customized housings are necessary for close-coupling, compensator and orifice)

Dimensions mm (inch)

5 5

Seal Material

Blank - Buna-N V- Viton®

4

Size

16 - 16 size

2

* – (S) – *** – 00 6

7

Spool Seals

Blank - No seal on spool S - Seal on spool (For load holding applications where leakage from port 1 to 2 could cause cylinder drift, use of seal will increase hysteresis)

6

Pressure Differential (Nominal)

40 - 2,8 bar (40 psi) 80 - 5,5 bar (80 psi) 160 - 11,0 bar (160 psi)

7

Special Features

00 - None (Only required if valve has special features, omit if "00".)

Torque into aluminum housing to 108-122 Nm (80-90 ft lbs) Torque into steel housing to 136-149 Nm (100-110 ft lbs)

Cartridge Only Basic Code PCS3-16

28,6 (1.12)

H

38,1 (1.50) hex

1.312 -12 Thd.

73,0 (2.87)

3

2 1

26,95 (1.061) 28,55 (1.124)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-451.A

PCS13-16 - Pressure Compensator Restrictive 114 L/min (30 USgpm) • 350 bar (5000 psi)

3

2

1

Sectional View

Operation

Features

This valve, when used with either a fixed or variable orifice between port 1 and port 3, maintains a constant flow. This is based on what ever pressure differential is chosen. Flow out of port 2, regardless of pressure, changes downstream on port 2.

Hardened and ground and honed working components. Cartridge construction for maximum mounting flexibility. Working pressure 350 bar.

Performance Data Ratings and Specifications

Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F) Typical application pressure (all ports) 350 bar (5000 psi) Cartridge fatigue pressure (infinite life) 350 bar (5000 psi) Rated flow 114 L/min (30 USgpm) Cavity C-16-3 Standard housing materials Customized housings are necessary for close-coupling, the compensator and orifice Temperature range -40° to 120°C (-40° to 248°F) Fluids All general purpose hydraulic fluids such as: MIL-H-5606, SAE 10, SAE 20, etc. Filtration Cleanliness code 18/16/13 Weight cartridge only 0,38 kg (.84 lbs) Seal kit 565811 (Buna-N) 889610 (Viton®) Viton is a registered trademark of E.I. DuPont

H

Description

Performance Characteristics

This is a high pressure restrictive style compensator suitable for use with a separate needle valve or orifice to provide a pressure compensated flow while the excess oil passes over a relief valve or closes down the compensator on a pump. This, when used in a manifold, is ideal for motor or cylinder speed control either meter in or meter out.

Cartridge Only 0

12

24

36

0.400 0.350

48

60

72

84

96

108 10

A

0.300

8

B

0.250

6

C

0.200 0.150

4

0.100 0.050 0

2 0

3

6

9

12

15

18

21

24

27

30

0

Approx. orifice diameter - mm

Approx. orifice diameter - inches

Controlled flow - L/min (21,8 cSt oil @ 49° C)

Controlled flow - USgpm (105 SUS oil @ 120° F)

A - 2,8 bar (40 psi) (control B - 5,5 bar (80 psi) (control C - 11,0 bar (160 psi) (control

P) P) P)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-460.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

PCS13-16 - Pressure Compensator Restrictive 114 L/min (30 USgpm) • 350 bar (5000 psi)



PCS13 – 16

Model Code



1 1

Function

PCS13 - Pressure compensator restrictive type

2

Size

2

(V) – 3

4

4 Port Size 0 - Cartridge only

5

(Customized housings are necessary for close-coupling, compensator and orifice)

16 - 16 Size

3

* – (S) – *** – 00 5

6

7

Spool Seals

Blank - No seal on spool S - Seal on spool. (For load holding applications were leakage from port 1 to 2 could cause cylinder drift, use of seal will increase hysteresis)

6

Pressure Differential

40 - 2,8 bar (40 psi) 80 - 5,5 bar (80 psi) 160 - 11,0 bar (160 psi)

7

Special Features

00 - None (Only required if valve has special features, omitted if “00.”)

Seals

Blank - Buna-N V - Viton®

Torque into aluminum housing to 108-122 Nm (80-90 ft. lbs)

Dimensions mm (inch)

Torque into steel housing to 136-149 Nm (100-110 ft. lbs)

Cartridge Only Basic Code PCS13-16

H 36,6 (1.44)

1 1/2" hex

1 5/16" - 12 UNF - 2A Thd.

3 73,1 (2.88)

2

1 26.90 - 26.94 (1.059 - 1.061) 28.50 - 28.54 (1.122 - 1.124)

WARNING Aluminum housings • can be used for pressures up to 210 bar (3000 psi). Steel housings must be used for operating pressures above 210 bar (3000 psi).

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-461.A

PCS3-20 - Pressure Compensator Restrictive 189 L/min (50 USgpm) • 210 bar (3000 psi)

Operation

3

2

Features This is based on what ever pressure differential is chosen. Flow out of port 2, regardless of pressure, changes downstream on port 2.

This valve, when used with either a fixed or variable orifice between port 1 and port 3, maintains a constant flow.

Hardened and ground and honed working components. Cartridge construction for maximum mounting flexibility.

1

Sectional View

Performance Data Ratings and Specifications

3

Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49° C (120° F) Typical application pressure (all ports) 210 bar (3000 psi) Cartridge fatigue pressure (infinite life) 210 bar (3000 psi) Rated flow 189 L/min (50 USgpm) Cavity C-20-3 Standard housing materials Customized housings are necessary for close-coupling, the compensator and orifice Temperature range -40° to 120° C (-40° to 248° F) Fluids All general purpose hydraulics fluids such as: MIL-H-5606, SAE 10, SAE 20 etc Filtration Cleanliness code 18/16/13 Weight cartridge only 0,88 kg (1.94 lbs) Seal kit 889616 (Buna-N), 02-175433 (Viton®) Viton is a registered trademark of E.I. DuPont

H

2

1

Description

Performance Characteristics

This is a restrictive style compensator suitable for use with a separate needle valve or orifice to provide a pressure compensated flow while the excess oil passes over a relief valve or closes down the compensator on a pump. This, when used in a manifold, is ideal for motor or cylinder speed control either meter in or meter out.

Cartridge only Controlled flow in L/min (21,8 cSt oil @ 49° C) 40

80

120

160

200 20

0.700

16

0.600

A

0.500

B

0.400 0.300

8

0.200 0.100 0

12

4 0

10 20 30 40 50 Controlled flow USgpm (105 SUS oil @ 120° F)

A - 2,8 bar (40 psi) (control B - 5,5 bar (80 psi) (control

0

Approx. orifice diameter - mm

Approx. orifice diameter - inches

0

P) P)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-470.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

PCS3-20 - Pressure Compensator Restrictive 189 L/min (50 USgpm) • 210 bar (3000 psi)

Model Code

PCS3 – 20 (V) –

1

1 Function

3

PCS3 - Pressure compensator restrictive type

2

Size

2

3

* – (S) – *** – 00 4 5

Seal Material

Blank - Buna-N V - Viton®

4

5

Port Size

20 - 20 size

0 - Cartridge only (Customized housings are necessary for close-coupling, compensator and orifice)

Dimensions mm (inch)

Torque into aluminum housing to 128-155 Nm (95-115 ft lbs)

6

7

Spool Seals

Blank - No seal on spool S - Seal on spool (For load holding applications where leakage from port 1 to 2 could cause cylinder drift, use of seal will increase hysteresis)

6

Pressure Differential (Nominal)

40 - 2,8 bar (40 psi) 80 - 5,5 bar (80 psi)

7

Special Features

00 - None (Only required if valve has special features, omit if "00".)

Cartridge Only Basic Code PCS3-20

H 41,3 (1.62)

47,6 (1.87) hex

1.625 -12 Thd. 3 98,4 (3.87) 2

1

33,30 (1.311) 36,47 (1.436)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-471.A

PCS4-10 - Pressure Compensator Bypass or priority 38 L/min (10 USgpm) • 210 bar (3000 psi)

1

2

4

3

Sectional View

Features

Operation the priority requirement is bypassed from port 1 to port 2. If the priority port is deadheaded, the valve will try to direct flow out of the priority port and shut off the bypass flow, blocking of all flow.

This valve, when used with either a fixed or variable orifice on port 4, maintains a constant flow out of port 3, regardless of pressure changes downstream of port 3. This is based on whatever pressure differential is chosen. All flow in excess of

Hardened and ground and honed working components. Cartridge construction for maximum mounting flexibility.

Performance Data Ratings and Specifications

4

3

H 2

Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49° C (120° F) Typical application pressure (all ports) 210 bar (3000 psi) Cartridge fatigue pressure (infinite life) 210 bar (3000 psi) Rated flow 38 L/min (10 USgpm) Cavity C-10-4 Standard housing materials Customized housings are necessary for close-coupling, the compensator and orifice Temperature range -40° to 120° C (-40° to 248° F) Fluids All general purpose hydraulics fluids such as: MIL-H-5606, SAE 10, SAE 20 etc Filtration Cleanliness code 18/16/13 Weight cartridge only 0,14 kg (0.32 lbs) Seal kit 889651 (Buna-N) 889653 (Viton®) Viton is a registered trademark of E.I. DuPont

Performance Characteristics

1

Cartridge only Controlled flow - L/min (21,8 cSt oil @ 49°C)

This is a priority style compensator suitable for use with a separate needle valve or orifice to provide a priority pressure compensated flow. This when used in a manifold is ideal for motor or cylinder control where priority is required.

4

8

12 16

20 24

28

32

36 5

0.200 0.175

4

A

0.150

B

0.125

C

0.100 0.075

2

0.050 0.025 0

3

1 0

1 2 3 4 5 6 7 8 9 10 Controlled flow - USgpm (105 SUS oil @ 120°F)

0

Approx. orifice diameter - mm

Description

Approx. orifice diameter - inches

0

A - 2,8 bar (40 psi) (control P) B - 5,5 bar (80 psi) (control P) C - 11,0 bar (160 psi) (control P)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-480.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

PCS4-10 - Pressure Compensator Bypass or priority 38 L/min (10 USgpm) • 210 bar (3000 psi)

PCS4 – 10 (V) –

Model Code

1

1 Function

3

PCS4 - Pressure compensator restrictive type

2

2

3

* – *** – 00 4

5 4

Seal Material

Blank - Buna-N V - Viton®

6

Port Size

0 - Cartridge only (Customized housings are necessary for close-coupling, compensator and orifice)

Size

10 - 10 size

5

Pressure Differential (Nominal)

40 - 2,8 bar (40 psi) 80 - 5,5 bar (80 psi) 160 - 11,0 bar (160 psi)

6

Special Features

00 - None (Only required if valve has special features, omit if ("00".)

Dimensions mm (inch)

Torque into aluminum housing to 47-54 Nm (35-40 ft lbs) Torque into steel housing to 68-75 Nm (50-55 ft lbs)

Cartridge Only Basic Code PSC4-10

H 19,0 (0.75)

25,4 (1.00) hex

0.875 -14 Thd. 4 61,9 (2.43) 3

2

1

15,80 (0.622) 17,40 (0.685) 18,97 (0.747)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-481.A

PCS14-10 - Pressure Compensator Bypass or priority 38 L/min (10 USgpm) • 350 bar (5000 psi) 1

2

4

3

Sectional View

Operation

Features priority requirement is bypassed from port 1 to port 2. If the priority port is deadheaded, the valve will try to direct flow out of the priority port and shut off the bypass flow, blocking of all flow.

This valve, when used with either a fixed or variable orifice on port 4, maintains a constant flow out of port 3, regardless of pressure changes downstream of port 3. This is based on whatever pressure differential is chosen. All flow in excess of the

Hardened and ground and honed working components. Cartridge construction for maximum mounting flexibility. Working pressure 350 bar.

Performance Data Ratings and Specifications

4

3

H

Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F) Typical application pressure (all ports) 350 bar (5000 psi) Cartridge fatigue pressure (infinite life) 350 bar (5000 psi) Rated flow 38 L/min (10 USgpm) Cavity C-10-4 Standard housing materials Customized housings are necessary for close-coupling, the compensator and orifice Temperature range -40° to 120°C (-40° to 248°F) Fluids All general purpose hydraulic fluids such as MIL-H-5606, SAE 10, SAE 20, etc. Filtration Cleanliness code 18/16/13 Weight cartridge only 0,14 kg (0.32 lbs) Seal kit 889651 (Buna-N) 889653 (Viton®) Viton is a registered trademark of E.I. DuPont

2

1 Description

Performance Characteristics

This is a high pressure priority style compensator suitable for use with a separate needle valve or orifice to provide a priority pressure compensated flow. This when used in a manifold is ideal for motor or cylinder control where priority is required.

Cartridge only

0.200 0.175

4

8

12 16 20 24

32

36

5 4

A

0.150 0.125 0.100 0.075 0.050 0.025 0

28

B

3

C

2 1 0

1

2

3

4

5

6

7

8

9

10

0

Approx. orifice diameter - mm

Approx. orifice diameter - inches

Controlled flow - L/min (21,8 cSt oil @ 49°C) 0

Controlled flow - USgpm (105 SUS oil @ 120°F)

A - 2,8 bar (40 psi) (control B - 5,5 bar (80 psi) (control C - 11,0 bar (160 psi) (control

P) P) P)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-490.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

PCS14-10 - Pressure Compensator Bypass or priority 38 L/min (10 USgpm) • 350 bar (5000 psi)



PCS14 – 10

Model Code



1 1

Function

PCS14 - Pressure compensator bypass type

2

Size

2

(V) –

* – *** – 00

3

4

4 Port Size 0 - Cartridge only

(Customized housings are necessary for close-coupling, compensator and orifice)

5

6

5 Pressure Differential (Nominal) 40 - 2,8 bar (40 psi) 80 - 5,5 bar (80 psi) 160 - 11,0 bar (160 psi)

6

Special Features

00 - None (Only required if valve has special features, omitted if “00.”)

10 - 10 Size

3

Seals

Blank - Buna-N V - Viton®

Torque into aluminum housing to 47-54 Nm (35-40 ft. lbs)

Dimensions mm (inch)

Torque into steel housing to 68-75 Nm (50-55 ft. lbs)

Cartridge Only Basic Code PCS14-10

25,65 (1.010)

25.4" (1.0) hex

H

7/8" - 14 Unf - 2A Thd.

4

62,0 (2.44)

3

2

1 15.78 - 15.82 (0.621 - 0.623) 17.38 - 17.42 (0.684 - 0.686) 18.95 - 18.99 (0.746 - 0.748)

WARNING Aluminum housings • can be used for pressures up to 210 bar (3000 psi). Steel housings must be used for operating pressures above 210 bar (3000 psi).

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-491.A

PCS4-12 - Pressure Compensator Bypass or priority 58 L/min (15 USgpm) • 240 bar (3500 psi) 1

2

4

3

Sectional View

Features

Operation the priority requirement is bypassed from port 1 to port 2. If the priority port is deadheaded, the valve will try to direct flow out of the priority port and shut off the bypass flow, blocking of all flow.

This valve, when used with either a fixed or variable orifice on port 4, maintains a constant flow out of port 3, regardless of pressure changes downstream of port 3. This is based on whatever pressure differential is chosen. All flow in excess of

Hardened and ground and honed working components. Cartridge construction for maximum mounting flexibility.

Performance Data Ratings and Specifications

4

3

Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49° C (120° F) Typical application pressure (all ports) 240 bar (3500 psi) Cartridge fatigue pressure (infinite life) 240 bar (3500 psi) Rated flow 58 L/min (15 USgpm) Cavity C-12-4 Standard housing materials Customized housings are necessary for close-coupling, the compensator and orifice Temperature range -40° to 120° C (-40° to 248° F) Fluids All general purpose hydraulics fluids such as: MIL-H-5606, SAE 10, SAE 20 etc Filtration Cleanliness code 18/16/13 Weight cartridge only 0,36 kg (0.80 lbs) Seal kit 9900335-000 (Buna-N) 9900336-000 (Viton®) Viton is a registered trademark of E.I. DuPont

H

2

1

Description

Performance Characteristics

This is a priority style compensator suitable for use with a separate needle valve or orifice to provide a priority pressure compensated flow. This when used in a manifold is ideal for motor or cylinder control where priority is required.

Cartridge only

External orifice diameter (inch)

0.350 0.300 A

0.250

B

0.200 C

0.150 0.100 0.050 0.000

0

A - 2,8 bar (40 psi) (control B - 5,5 bar (80 psi) (control C - 11,0 bar (160 psi) (control

5

Flow (GPM)

10

15

P) P) P)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-500.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

PCS4-12 - Pressure Compensator Bypass or priority 58 L/min (15 USgpm) • 240 bar (3500 psi)

Model Code

PCS4 – 12 (V) –

1

1 Function

PCS4 - Pressure compensator restrictive type

2

3

2

3

* – *** – 00 4

5 4

Seal Material

6

Port Size

0 - Cartridge only (Customized housings are necessary for close-coupling, compensator and orifice)

Blank - Buna-N V - Viton®

Size

12 - 12 size

6

Pressure Differential (Nominal)

40 - 2,8 bar (40 psi) 80 - 5,5 bar (80 psi) 120 - 8,3 bar (120 psi)

7

Special Features

00 - None (Only required if valve has special features, omit if "00".)

Dimensions mm (inch) Cartridge Only Basic Code PCS4-12

Torque into aluminum housing to 81-95 Nm (60-70 ft lbs) Torque into steel housing to 102-115 Nm (75-85 ft lbs)

H

31,7 (1.25) HEX 33,3 (1.31) 1 1/16 - 12 UNF - 2A THREAD

90,2 (3.55)

20,6 (.810) 22,1 (.872) 23,7 (.935)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-501.A

PCS14-12 - Pressure Compensator Bypass or priority 58 L/min (15 USgpm) • 350 bar (5000 psi) 1

2

4

3

Sectional View

Operation

Features priority requirement is bypassed from port 1 to port 2. If the priority port is deadheaded, the valve will try to direct flow out of the priority port and shut off the bypass flow, blocking of all flow.

This valve, when used with either a fixed or variable orifice on port 4, maintains a constant flow out of port 3, regardless of pressure changes downstream of port 3. This is based on whatever pressure differential is chosen. All flow in excess of the

Hardened and ground and honed working components. Cartridge construction for maximum mounting flexibility. Working pressure 350 bar.

Performance Data Ratings and Specifications

4

3

Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F) Typical application pressure (all ports) 350 bar (5000 psi) Cartridge fatigue pressure (infinite life) 350 bar (5000 psi) Rated flow 58 L/min (15 USgpm) Cavity C-12-4 Standard housing materials Customized housings are necessary for close-coupling, the compensator and orifice Temperature range -40° to 120°C (-40° to 248°F) Fluids All general purpose hydraulic fluids such as: MIL-H-5606, SAE 10, SAE 20, etc. Filtration Cleanliness code 18/16/13 Weight cartridge only 0,36 kg (0.80 lbs) Seal kit 9900335-000 (Buna-N) 9900336-000 (Viton®) Viton is a registered trademark of E.I. DuPont

H

2

1 Description

Performance Characteristics

This is a high pressure priority style compensator suitable for use with a separate needle valve or orifice to provide a priority pressure compensated flow. This when used in a manifold is ideal for motor or cylinder control where priority is required.

Cartridge only 0.350

EXTERNAL ORIFICE DIAMETER (INCH)

0.300 A 0.250

B

0.200 C

0.150 0.100 0.050 0.000

0

5

A - 2,8 bar (40 psi) (control B - 5,5 bar (80 psi) (control C - 11,0 bar (160 psi) (control

FLOW (GPM)

10

15

P) P) P)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-510.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

PCS14-12 - Pressure Compensator Bypass or priority 58 L/min (15 USgpm) • 350 bar (5000 psi)



PCS14 – 12

Model Code



1 1

* – *** – 00

3

4

4 Port Size 0 - Cartridge only

Function

PCS14 - Pressure compensator bypass type

2

2

(V) –

5

(Customized housings are necessary for close-coupling, compensator and orifice)

Size

12 - 12 Size

3

5

6

Pressure Differential (Nominal)

40 - 2,8 bar (40 psi) 80 - 5,5 bar (80 psi) 120 - 8,3 bar (120 psi) 160 - 11,0 bar (160 psi)

6

Special Features

00 - None (Only required if valve has special features, omitted if “00.”)

Seals

Blank - Buna-N V - Viton®

Torque into aluminum housing to 81-95 Nm (60-70 ft. lbs)

Dimensions mm (inch)

Torque into steel housing to 102-115 Nm (75-85 ft. lbs) Cartridge Only Basic Code PCS14-12

22,86 (0.900)

H

1.25" hex (31.75)

1 1/16" - 12 Un - 2A Thd.

4

91,69 (3.610)

3

2

-A-

1

Ø 20.55 - 20.59 (0.809 - 0.811) Ø 22.15 - 22.19 (0.872 - 0.874) Ø 23.73 - 23.77 (0.934 - 0.936)

WARNING Aluminum housings • can be used for pressures up to 210 bar (3000 psi). Steel housings must be used for operating pressures above 210 bar (3000 psi).

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-511.A

PCS4-16 - Pressure Compensator Bypass or priority 114 L/min (30 USgpm) • 210 bar (3000 psi) 1

2

4

Features

Operation the priority requirement is bypassed from port 1 to port 2. If the priority port is deadheaded, the valve will try to direct flow out of the priority port and shut off the bypass flow, blocking of all flow.

This valve, when used with either a fixed or variable orifice on port 4, maintains a constant flow out of port 3, regardless of pressure changes downstream of port 3. This is based on whatever pressure differential is chosen. All flow in excess of

3

Hardened and ground and honed working components. Cartridge construction for maximum mounting flexibility.

Performance Data

Sectional View

Ratings and Specifications

4

3

Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49° C (120° F) Typical application pressure (all ports) 210 bar (3000 psi) Cartridge fatigue pressure (infinite life) 210 bar (3000 psi) Rated flow 114 L/min (30 USgpm) Cavity C-16-4 Standard housing materials Customized housings are necessary for close-coupling, the compensator and orifice Temperature range -40° to 120° C (-40° to 248° F) Fluids All general purpose hydraulics fluids such as: MIL-H-5606, SAE 10, SAE 20 etc Filtration Cleanliness code 18/16/13 Weight cartridge only 0,50 kg (1.12 lbs) Seal kit 889660 (Buna-N), 02-175435 (Viton®) Viton is a registered trademark of E.I. DuPont

H

2

1 Description

Performance Characteristics

This is a priority style compensator suitable for use with a separate needle valve or orifice to provide a priority pressure compensated flow. This when used in a manifold is ideal for motor or cylinder control where priority is required.

Cartridge only

0

15

30

45

0.400 0.350

60

75

90

105 10

A

0.300

8

B

0.250

6

C

0.200 0.150

4

0.100 0.050 0

2 0

3

6

9

12

15

18

21

24

27

30

0

Approx. orifice diameter - mm

Approx. orifice diameter - inches

Controlled priority flow, port 3 - L/min (21,8 cSt oil @ 49˚ C)

Controlled priority flow, port 3 - USgpm (105 SUS oil @ 120˚ F)

A - 2,8 bar (40 psi) (control P) B - 5,5 bar (80 psi) (control P) C - 11,0 bar (160 psi) (control P) Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-520.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

PCS4-16 - Pressure Compensator Bypass or priority 114 L/min (30 USgpm) • 210 bar (3000 psi)

Model Code

PCS4 – 16 (V) –

1

Function

PCS4 - Pressure compensator restrictive type

2

1

2

3

Seal Material

* – *** – 00

3

4

5 4

6

Port Size

0 - Cartridge only (Customized housings are necessary for close-coupling, compensator and orifice)

Blank - Buna-N V - Viton®

Size

16 - 16 size

5

Pressure Differential (Nominal)

40 - 2,8 bar (40 psi) 80 - 5,5 bar (80 psi) 160 - 11,0 bar (160 psi)

6

Special Features

00 - None (Only required if valve has special features, omit if "00".)

Dimensions mm (inch)

Torque into aluminum housing to 108-122 Nm (80-90 ft lbs) Torque into steel housing to 136-149 Nm (100-110 ft lbs)

Cartridge Only Basic Code PCS4-16

H 28,6 (1.12)

38,1 (1.50) hex

1.312 -12 Thd. 4 101,6 (4.00) 3

2

1

25,37 (0.999) 26,95 (1.061) 28,55 (1.124)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-521.A

PCS14-16 - Pressure Compensator Bypass or priority 114 L/min (30 USgpm) • 350 bar (5000 psi) 1

2

4

3

Sectional View

Features

Operation chosen. All flow in excess of the priority requirement is bypassed from port 1 to port 2. If the priority port is deadheaded, the valve will try to direct flow out of the priority port and shut off the bypass flow, blocking of all flow.

This valve, when used with either a fixed or variable orifice on port 4, maintains a constant flow out of port 3, regardless of pressure changes downstream of port 3. This is based on whatever pressure differential is

Hardened and ground and honed working components. Cartridge construction for maximum mounting flexibility. Working pressure 350 bar (5000 psi).

Performance Data Ratings and Specifications

4

3

Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49°C (120°F) Typical application pressure (all ports) 350 bar (5000 psi) Cartridge fatigue pressure (infinite life) 350 bar (5000 psi) Rated flow 114 L/min (30 USgpm) Cavity C-16-4 Standard housing materials Customized housings are necessary for close-coupling, the compensator and orifice Temperature range -40° to 120°C (-40° to 248°F) Fluids All general purpose hydraulic fluids such as MIL-H-5606, SAE 10, SAE 20, etc. Filtration Cleanliness code 18/16/13 Weight cartridge only 0,50 kg (1.12 lbs) Seal kit 889660 (Buna-N) 02-175435 (Viton®) Viton is a registered trademark of E.I. DuPont

H

2

1 Description

Performance Characteristics

This is a high pressure priority style compensator suitable for use with a separate needle valve or orifice to provide a priority pressure compensated flow. This when used in a manifold is ideal for motor or cylinder control where priority is required.

Cartridge only 0

15

30

45

0.400 0.350

60

75

90

105 10

A

0.300

8

B

0.250

6

C

0.200 0.150

4

0.100 0.050 0

2 0

3

6

9

12

15

18

21

24

27

30

0

Approx. orifice diameter - mm

Approx. orifice diameter - inches

Controlled priority flow, port 3 - L/min (21,8 cSt oil @ 49˚ C)

Controlled priority flow, port 3 - USgpm (105 SUS oil @ 120˚ F)

A - 2,8 bar (40 psi) (control B - 5,5 bar (80 psi) (control C - 11,0 bar (160 psi) (control

P) P) P)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-530.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

PCS14-16 - Pressure Compensator Bypass or priority 114 L/min (30 USgpm) • 350 bar (5000 psi)



PCS14 – 16

Model Code



1 1

Function

PCS14 - Pressure compensator bypass type

2

Size

2

(V) –

* – *** – 00

3

4

4 Port Size 0 - Cartridge only

(Customized housings are necessary for close-coupling, compensator and orifice)

5

6

5 Pressure Differential (Nominal) 40 - 2,8 bar (40 psi) 80 - 5,5 bar (80 psi) 160 - 11,0 bar (160 psi)

6

Special Features

00 - None (Only required if valve has special features, omitted if “00.”)

16 - 16 Size

3

Seals

Blank - Buna-N V - Viton®

Dimensions mm (inch)

Torque into aluminum housing to 108-122 Nm (80-90 ft. lbs) Torque into steel housing to 136-149 Nm (100-110 ft. lbs)

Cartridge Only Basic Code PCS14-16

36,6 (1.44)

1 1/2" hex

H

1 5/16" - 12 Unf - 2A Thd.

4

101,6 (4.00)

3

2

1

25.33 - 25.37 (0.997 - 0.999) 26.90 - 26.94 (1.059 - 1.061) 28.50 - 28.54 (1.122 - 1.124)

WARNING Aluminum housings • can be used for pressures up to 210 bar (3000 psi). Steel housings must be used for operating pressures above 210 bar (3000 psi). Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-531.A

PCS4-20 - Pressure Compensator Bypass or priority 189 L/min (50 USgpm) • 210 bar (3000 psi) 1

2

4

Operation

3

Features All flow in excess of the priority requirement is bypassed from port 1 to port 2. If the priority port is deadheaded, the valve will try to direct flow out of the priority port and shut off the bypass flow, blocking of all flow.

This valve, when used with either a fixed or variable orifice on port 4, maintains a constant flow out of port 3, regardless of pressure changes downstream of port 3. This is based on whatever pressure differential is chosen.

Hardened and ground and honed working components. Cartridge construction for maximum mounting flexibility.

Performance Data

Sectional View

Ratings and Specifications

4

3

Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49° C (120° F) Typical application pressure (all ports) 210 bar (3000 psi) Cartridge fatigue pressure (infinite life) 210 bar (3000 psi) Rated flow 189 L/min (50 USgpm) Cavity C-20-4 Standard housing materials Customized housings are necessary for close-coupling, the compensator and orifice Temperature range -40° to 120° C (-40° to 248° F) Fluids All general purpose hydraulics fluids such as: MIL-H-5606, SAE 10, SAE 20 etc Filtration Cleanliness code 18/16/13 Weight cartridge only 0,50 kg (1.12 lbs) Seal kit 889660 (Buna-N) 02-175435 (Viton®) Viton is a registered trademark of E.I. DuPont

H

2

Performance Characteristics

This is a priority style compensator suitable for use with a separate needle valve or orifice to provide a priority pressure compensated flow. This when used in a manifold is ideal for motor or cylinder control where priority is required.

Cartridge only

Approx. orifice diameter - inches

Descriptions

Controlled priority flow port 3 - L/min (21,8 cSt oil @ 49˚ C) 0 35 70 105 140 175 210 245 0.600 15 0.500

12 A

0.400

B

9

0.300 0.200

6

0.100

3

0

0

7

14

21

28

35

42

49

56

63

70

0

Approx. orifice diameter - mm

1

Controlled priority flow port 3 - USgpm (105 SUS oil @ 120˚ F)

A - 2,8 bar (40 psi) (control B - 5,5 bar (80 psi) (control

P) P)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-540.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

PCS4-20 - Pressure Compensator Bypass or priority 189 L/min (50 USgpm) • 210 bar (3000 psi)

PCS4 – 20 (V) –

Model Code

1

1 Function

3

PCS4 - Pressure compensator bypass type

2

2

3

* – *** – 00 4

5 4

Seal Material

6

Port Size

0 - Cartridge only (Customized housings are necessary for close-coupling, compensator and orifice)

Blank - Buna-N V - Viton®

Size

5

40 - 2,8 bar (40 psi) 80 - 5,5 bar (80 psi)

6

20 - 20 size

Pressure Differential (Nominal)

Special Features

00 - None (Only required if valve has special features, omit if "00".)

Dimensions mm (inch)

Torque into aluminum housing to 128-155 Nm (95-115 ft lbs)

Cartridge Only Basic Code PCS4-20

41,3 (1.62)

H

47,6 (1.87) hex

1.625 -12 Thd. 4 139,7 (5.50)

3

2

1

31,70 (1.248) 33,30 (1.311) 36,47 (1.436)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-541.A

2FPH - Flow Regulator Pressure compensated regulator/diverter, priority style. solenoid switch Up to 160 L/min (42 USgpm) • 350 bar (5000 psi)

Operation Inlet (1)

Reg.(2)

By-pass (3)

Drain (4)

Sectional View

Features flow ports. The solenoid valve vents the spring chamber to a drain line and in its NORMAL (de-energized) mode all inlet flow is diverted to the bypass port. The pre-set regulated flow is selected by energizing the solenoid. The adjustable relief valve vents the spring chamber at the pre-set pressure and diverts the flow to the bypass port. It may be necessary to fit a 10 bar check valve in the bypass or regulated line to ensure the valve switches fully.

Inlet flow passes through the adjustable orifice and the radial holes in the spool/ sleeve assembly then out of the regulated port. The pressure drop across the orifice is sensed at each end of the spool, producing a force which, at the required flow rate, overcomes the spring force. The resultant movement of the spool regulates the flow by opening the radial valve ports to the bypass port and closing the regulated

Line body construction with three ports allows direct connection into hydraulic systems. Leakproof adjust screw gives easy, accurate adjustment to required flow setting. Remote functional selection with solenoid operation. Adjustable relief valve gives system protection. Hardened and ground working parts give accurate flow control and long working life.

Performance Data Ratings and Specifications

Figures based on oil temperature of 40˚ C and of 32 cSt (150 SUS)

Inlet (1)

Bypass (3)

Reg (2)

H 1

2

Inlet 3

4

Rated flow Maximum pressure Material Standard housing material Mounting position Weight Seal kit number Recommended filtration level Operating temperature Nominal range

Inlet 2FPH55 95 L/min (25 USgpm) 2FPH95 150 L/min (40 USgpm) 2FPH195 380 L/min (100 USgpm) Regulated 2FPH55 55 L/min (14 USgpm) 2FPH95 95 L/min (25 USgpm) 2FPH195 160 L/min (42 USgpm) 2FPH55 280 bar (4000 psi) 2FPH95/2FPH195 350 bar (5000 psi) All working parts hardened & ground steel 2FPH55 Aluminum (up to 210 bar) 2FPH95/2FPH195 Steel Line mounted 2FPH55 3.00 Kg (6.60 lbs) 2FPH95 3.50 Kg (7.70 lbs) 2FPH195 12.26 Kg (27.00 lbs) 2FPH55 SK267 (Nitrile) SK267V (Vition) 2FPH95 SK547 (Nitrile) SK547V (Viton) 2FPH195 SK258 (Nitrile) SK258V (Viton) BS5540/4 Class 18/13 (25 micron nominal) –30° to +90°C (–22° to +194°F) 5 to 500 cSt

Viton is a registered trademark of E.I. DuPont

Description

Pressure Drop

Load pressure - psi 1400 2800

15

50

12.5

40

10

35

30

7.5

25

20

5

15

10

2.5

55

2FPH55

45

0

0 200

100

0

100

200

Load pressure - bar

Regulated flow - L/min

0 60

65

Regulated flow - US gpm

2800 1400

Load pressure - psi Bypass higher than regulated pressure

Regulated higher than bypass pressure

290

2800 1400

Regulated higher than bypass pressure

0

1400 2800

2FPH195 2FPH95

235

65 52

165

39

115

26

60

13 0

0 200

100

0

100

200

Regulated flow - US gpm

Bypass higher than regulated pressure

Regulated flow - L/min

The 2FPH series of priority flow regulator valves gives full control of regulated flow plus remote selection of priority flow and adjustable pressure limitation of the regulated line.

Load pressure - bar

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-550.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

2FPH - Flow Regulator Pressure compensated regulator/diverter, priority style. solenoid switch Up to 160 L/min (42 USgpm) • 350 bar (5000 psi)

2FPH** –

Model Code

P

1 1

3

Basic Code

2FPH55 - Complete valve 2FPH95 - Complete valve 2FPH195 - Complete valve

2

Adjustment means

P - Leakproof screw adjustment R - Handknob adjustment (See page H-6 for dimensions)

Code

Port Size

2FPH55 2FPH95 2FPH195

1/2" 3/4" 1"

A

6W – 95 –

2

3

4

Port Size - Bodied Valves Only

4

4W - 1/2" BSP 6W - 3/4" BSP 8W - 1" BSP 8T - 1/2" SAE 12T - 3/4" SAE 16T - 1" SAE

B

C

H

24

5

6

7 6

Adjustable Flow Range

5

Other terminations available on request

Seals

S - Nitrile (for use with most industrial hydraulic oils) SV - Viton (for high temperature & most special fluid applications) E

127 127 168

F

44.5 82.5 58 102 47 104

G

H

K

L

- 58 108

32 39.5 32

28.5 32 67

8.5 10 13

M

Coil Termination

H - ISO 4400 (plug included) F - Flying leads, DC only DM - Deutsch moulded

2FPH55 - 0-55 liters/min 2FPH95 - 0-95 liters/min 2FPH195 - 0-195 liters/min

D

168 51 76 232 63.5 76 227.5 63.5 133

– S

N

10 95 10 136 13 127

7

Voltage

12 - 12 VDC 24 - 24 VDC Other options available on request

O

P

Std R/V

Ø8.5 Ø10.5 Ø13.5

SX203 S207 S207

280 bar 200 bar 280 bar

Note: For applications above 210 bar please consult our technical department or use the steel body option

Dimensions mm (inch) Complete Valve Basic Code 2FPH

H P 1DR2-P-40S

M

N

4

1 D

C

Tank drain line Do not block 1/4” BSP (1/4” SAE)

G

K

3

2

E

H

F

B O

A Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-551.A

2FPH - Flow Regulator Pressure compensated regulator/diverter, priority style. solenoid switch 350 L/min (92 USgpm) • 350 bar (5000 psi) LS Inlet

Reg.

By-pass

Drain

Operation

Features

Inlet flow passes through the adjustable orifice and the radial holes in the spool/ sleeve assembly then out of the regulated port. The pressure drop across the orifice is sensed at each end of the spool, producing a force which, at the required flow rate, overcomes the spring force. The resultant movement of the spool regulates the flow by opening more radial holes to the bypass port. The solenoid valve vents the spring chamber to a drain line

and in its de-energized mode all inlet flow is diverted to the bypass port. The pre-set regulated flow is selected by energizing the solenoid. The adjustable pilot valve vents the spring chamber when the regulated line reaches the preset pressure, diverting the flow to the bypass port where the pressure can continue to rise if necessary. It may be necessary to fit a 10 bar check valve in the bypass or regulated line to ensure the valve switches fully.

Line body construction with three ports allows direct connection into hydraulic systems. Leakproof adjust screw gives easy, accurate adjustment to required flow setting. Remote functional selection with solenoid operation. Adjustable relief valve gives system protection whilst allowing bypass pressure to rise above setting if required. Hardened and ground working parts give accurate flow control and long working life.

Performance Data Ratings and Specifications

Figures based on oil temperature of 40˚ C and of 32 cSt (150 SUS) Rated flow Inlet 2FPH250 350 L/min (92 USgpm) 2FPH350 450 L/min (120 USgpm) Regulated 2FPH250 200 L/min (52 USgpm) 2FPH350 350 L/min (92 USgpm) Maximum pressure 350 bar (5000 psi) Material All working parts hardened & ground steel Standard housing material Steel, zinc plated and passivated Mounting position Line mounted Weight 2FPH250 17 kg (37.4 lbs) 2FPH350 28 kg (61.0 lbs) Seal kit number 2FPH250 SK819 (Nitrile), SK819V (Viton®) 2FPH350 SK820 (Nitrile), SK820V (Viton®) Recommended filtration level BS5540/4 Class 18/13 (25 micron nominal) Operating temperature -30° to +90° C (–22° to +194° F) Nominal range 5 to 500 cSt

H

Viton is a registered trademark of E.I. DuPont

Description

Pressure Drop

Load pressure - psi

0

250

2000

4000

2FPH250

200

78 65 52

150

39

100

26

50

13 0

0 300

150

0

150

300

Load pressure - bar

Regulated flow - L/min

4000 2000

Regulated flow - US gpm

300

Bypass higher than regulated pressure

Regulated higher than bypass pressure

300

4000 2000

Regulated higher than bypass pressure

0

250

2000 4000

65

2FPH350

200

78 52

150

39

100

26

50

13 0

0 300 150

0

150

300

Regulated flow - US gpm

Load pressure - psi Bypass higher than regulated pressure

Regulated flow - L/min

The 2FPH series of priority flow regulator valves gives full control of regulated flow plus remote selection of priority flow and adjustable pressure limitation of the regulated line.

Load pressure - bar

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-560.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

2FPH - Flow Regulator Pressure compensated regulator/diverter, priority style. solenoid switch 350 L/min (92 USgpm) • 350 bar (5000 psi)

2FPH*** –

Model Code

1 1

3

Basic code

2FPH250 - Complete valve

2

3

4

Port size - bodied valves only

4

8W - 1" BSP 12W - 1 1/2" BSP 16T - 1" SAE 24T - 1 1/2" SAE

2FPH350 - Complete valve

2

8W – 250

P

Adjustment means

Port Size

A

1" 1-1/2"

177 269

24

5

6

7 6

Adjustable Flow Range

5

terminations available on request

Seals

S - Nitrile (for use with most industrial hydraulic oils) SV - Viton (for high temperature & most special fluid applications) B

C

D

E

63.5 177.8 75 76.2 177.8 75

F

G

70 31.75 143 70 38.1 100

H

K

47.5 89

L

M

N

Coil termination

H - ISO 4400 (plug included) F - Flying leads, DC only DM - Deutsch mouldedOther

350 - 0-350 L/min (2FPH350)

Adjustment

2FPH250 2FPH350

H

250 - 0-250 L/min (2FPH250)

P - Leakproof Screw

Basic Code

S

O

7

Voltage

12 - 12 VDC 24 - 24 VDC Other options available on request P

O

R

105 15 62 110 95 63 13.5 - 164 5 62 15 100 39 18.0 90

S

Std R/V

- 280 bar 50 200 bar

Dimensions mm (inch) Complete Valve Basic Code 2FPH F

S

N

P

H

C Inlet

M

G

R

B

ØQ L

J H

K

Tank drain line Do not block

F Reg

Bypass A

LS D D

E

Load sensing port 1/4” BSP (1/4” SAE)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-561.A

VF1-10/VF11-10 - Velocity Fuse 23 L/min (6 USgpm) • Up to 350 bar (5000 psi)

Reverse flow direction

Fusing direction

2

1

Sectional View

Operation

Features

This valve is normally open from port 1 to port 2. When flow exceeds the setting of the valve, it closes. The valve returns to the open condition when the pressure at port 1 is reduced to less than 80 psi.

Hardened and ground and honed working components. Cartridge construction for maximum mounting flexibility.

Performance Data

Ratings and Specifications

Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F) Typical application pressure (all ports) VF1/VF11 210 bar (3000 psi) / 350 bar (5000 psi) Cartridge fatigue pressure (infinite life) VF1/VF11 210 bar (3000 psi) / 350 bar (5000 psi) Rated Flow 23 L/min (6 USgpm) Flow regulation accuracy 1,9–22,7 L/min (0.5–6.0 USgpm) ±20% Factory set maximum flow rate accuracy under standard test conditions and within the above ranges

2

H

Internal leakage Port 2 to 1; <5 drops/min, maximum @ 210 bar (3000 psi) Temperature range -40° to 120°C (-40° to 248°F) Cavity C–10–2 Fluids All general purpose hydraulics fluids such as: MIL-H-5606, SAE 10, SAE 20, etc Filtration Cleanliness code 18/16/13 Standard housing materials Aluminium or steel Weight 0,11 kg (0.25 lbs) Seal kit 565803 (Buna-N) 566086 (Viton®) Viton is a registered trademark of E.I. DuPont

1 Note: The valve is not intended for use in pump unloading applications

Pressure Drop

Cartridge only Pressure drop - bar 3

0

7

10

14

17

8 Flow - USgpm (105 SUS oil @ 120°F)

This is a screw in cartridge velocity fuse used to lock a cylinder or motor in place in the case of a complete hose failure.

20 30 25

6

20 A

4

15 10

B

2

5

C 0

0

45

100 150 200 Pressure drop - psi

Flow - L/min (21,8 cSt oil @ 49°C)

Description

250 300

A - 22,8 L/min (6 USgpm) maximum flow setting

B - 14,44 L/min (3 USgpm) maximum flow setting

C - 3,8 L/min (1 USgpm) maximum flow setting

Port 1 to 2, fusing direction

Port 1 to 2, fusing direction

Port 1 to 2, fusing direction







 ort 2 to 1, reverse P flow down to 0

 ort 2 to 1, reverse P flow down to 0

 ort 2 to 1, reverse P flow down to 0

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-570.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

VF1-10/VF11-10 - Velocity Fuse 23 L/min (6 USgpm) • Up to 350 bar (5000 psi)

VF(*)1 – 10

Model Code

1 1 Function

2

(V) – F – ** – *.* – 00 3

4

5

6

7

5 Port Size

VF1 - Velocity fuse 210 bar

Code

(3000 psi) VF11 - V  elocity fuse 350 bar (5000 psi)

Port Size

6 Factory Set Flow Rate Housing Number

Aluminium Light Duty 0 Cartridge only (A)3B 3/8" BSPP 02–175462 (A)6T SAE 6 566151 (A)2G 1/4" BSPP – (A)3G 3/8" BSPP – (A)6H SAE 6 – (A)8H SAE 8 – S6T SAE 6 – S8T SAE 8 – S2G 1/4” BSPP – S3G 3/8” BSPP – See section J for housing details.

2 Size 10 - Size

3 Seals N or Blank - Buna-N V - Viton®

4 Adjustment F - Fixed orifice

(Specify in USgpm) Range 1,9-22,7 L/min ((0.5 - 6.0 USgpm)

Aluminium Fatigue Rated

Steel

– – 876702 876703 876700 876701 – – – –

– – – – – – 02-175100 02-175101 02-175102 02-175103

7 Special Features 00 - None (Only required if valve has special features, omitted if "00".)

Torque cartridge in housing: A - 47-54 Nm (35-40 ft lbs) S - 68-75 Nm (50-55 ft lbs)

Dimensions mm (inch)

H

Cartridge Only Basic Code VF1/11

Installation Drawing (Steel) 28.6 (1.13)

25,4 (1.00) hex

19,0 (0.75)

0.81 (20.7)

19 (0.75)

50.8 (2.00)

0.875"-14 Thd. 31,7 (1.25) 2

1

76.2 (3.00)

1.25 (31.7) 95 (0.37)

ø15,82 (0.623)

2 X Ø7 .14 0.875"-14 Thd. (0.281)

44.45 (1.75) 63.5 (2.50)

1

22.2 (0.87)

2

44.45 (1.75)

.62 (15.8) WARNING Aluminum housings can be used for pressures up to 210 bar (3000 psi). Steel housings must be used for operating pressures above 210 bar (3000 psi).



Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-571.A

VF1-16 - Velocity Fuse 114 L/min (30 USgpm) • 210 bar (3000 psi)

Reverse flow direction

Fusing direction

2

1

Operation

Features

This valve is normally open from port 1 to port 2. When flow exceeds the setting of the valve, it closes. The valve returns to the open condition when the pressure at port 1 is reduced to less than 80 psi.

Hardened and ground and honed working components. Cartridge construction for maximum mounting flexibility.

Performance Data

Sectional View

Ratings and Specifications

Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F) Typical application pressure (all ports) 210 bar (3000 psi) Cartridge fatigue pressure (infinite life) 210 bar (3000 psi) Rated flow 114 L/min (30 USgpm) Flow regulation accuracy 9,5–114 L/min (2.5–30.0 USgpm) ±20% Factory set maximum flow rate accuracy under standard test conditions and within the above ranges

2

1

Internal leakage Temperature range Cavity Fluids Filtration Standard housing materials Weight cartridge only Seal kit

Port 1 to 2 closed; <5 drops/min maximum @ 210 bar (3000 psi) -40° to 120°C (-40° to 248°F) C–16–2 All general purpose hydraulic fluids such as MIL–H–5606, SAE 10, SAE 20, etc. Cleanliness code 18/16/13 Aluminum 0,33 kg (0.72 lbs) 565810 (Buna-N) 889609 (Viton®)

Viton is a registered trademark of E.I. DuPont

H

Pressure drop - bar 40

3

0

7

10

14

17

150 125

30

100

A

75

20 B

50

10

25

C 0

20

0

45

100

150

200

250

Flow - L/min (21,8 cSt oil @ 49°C)

Note: The valve is not intended for use in pump unloading applications.

Pressure Drop

Cartridge only

Flow - USgpm (105 SUS oil @ 120°F)

Description This is a screw in cartridge velocity fuse used to lock a cylinder or motor in place in the case of a complete hose failure.

300

Pressure drop - psi

A - 114 L/min (30 USgpm) maximum flow setting

B - 60 L/min (15 USgpm) maximum flow setting

Port 1 to 2, fusing direction

 ort 2 to 1, reverse P flow down to 0

C - 19 L/min (5 USgpm) maximum flow setting

Port 1 to 2, fusing direction

 ort 2 to 1, reverse P flow down to 0

Port 1 to 2, fusing direction

 ort 2 to 1, reverse P flow down to 0

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-580.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

VF1-16 - Velocity Fuse 114 L/min (30 USgpm) • 210 bar (3000 psi)

VF1 – 16

Model Code

1 1 Function

(V) – F – *** – ** – 00

2

3

4

5

6

7

5 Port Size

VF1 - Velocity fuse

Code

6 Factory Set Flow Rate

Port Size

2 Size 16 - 16 size

3 Seals Blank - Buna-N V - Viton®

4 Style F - Factory set

Torque cartridge in aluminum housing to 108–122 Nm (80–90 ft lbs)

Dimensions

mm (inch)

(Specify in USgpm) Range 9,5-114 L/min ((2.5-30 USgpm)

Housing Number

Aluminium Light Duty 0 Cartridge only 6B 3/4" BSPP 02–175463 12T SAE 12 566149 4G 1/2" BSPP – 6G 3/4” BSPP – 10H SAE 10 – 12H SAE 12 – See section J for housing details.

Aluminium Fatigue Rated

7 Special Features

– – 876716 876718 876717 566113

00 - None (Only required if valve has special features, omitted if "00".)

Vickers spreadsheet has VF1-16ph1.eps = A-2673-003 cartridge and A-3476-XXX housing. PDF says cartridge scale is off but I checked measurements on this cartridge and it's height of 41.3 is proportionate.

H

Installation Drawing

Cartridge Only Basic Code VF1-16

38,1 (1.5) hex

28.4 (1.12)

29,0 (1.13) 63.5 (2.50)

1.312"?-12 Thd. 44,5 (1.75)

2

88.9 (3.50)

2

2X 8.74 (.344) 1

10.3 (0.41)

31.8 (1.25)

68.28 (2.688) 88.9 (3.50)

1 Ø28,55 (1.124) WARNING Aluminum housings can be used for pressures up to 210 bar (3000 psi). Steel housings must be used for operating pressures above 210 bar (3000 psi).



Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-581.A

FDC1-16 - Flow Divider/Combiner Pressure compensated, spool type Up to 178 L/min (47 USgpm) • 210 bar (3000 psi)

2

4

Features

Operation in either direction causes the spool to move and close the radial holes in the sleeve until equilibrium is restored. In the reverse direction the spools close together and regulate the flow in through the radial ports.

Inlet flow passes through the two matched orifices in the spools, through the spools and out of the radial holes in the sleeve. The matched orifices and the compensating springs ensure that the flow is divided equally, excess flow

3

Sectional View

One valve synchronizes in both directions. Matched spools give high accuracy under load and pressure imbalance conditions. Cartridge construction gives versatility of application. A valve may be fitted into a line body, a custom designed Hydraulic Integrated Circuit or other hydraulic equipment.

Performance Data Ratings and Specifications

4

3

Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F) Typical application pressure (all ports) 210 bar (3000 psi) Cartridge fatigue pressure (infinite life) 210 bar (3000 psi) Rated inlet flow See model code Temperature range -40° to 120° C (-40° to 248° F) Cavity C–16–4 Fluids All general purpose hydraulic fluids such as MIL–H–5606, SAE 10, SAE 20, etc. Filtration Cleanliness code 18/16/13 Standard housing materials Aluminum Weight cartridge only 0,35 kg (0.78 lbs) Seal Kits 889634 (Buna–N) 889638 (Viton®) Viton is a registered trademark of E.I. DuPont

2

H

1 Pressure Drop

This range of flow divider/ combiner valves gives division of input flow into two equal parts and re-combination of flow in the reverse direction. Pressure compensation ensures that whether dividing or combining, equal flow is maintained over a wide range of pressure variation. A typical use of these valves is to divide a pump flow to operate two actuators (which may be under different load conditions and at different pressures) and to re-combine the return flows to synchronize actuator movement. Flow variation is within ±10% with the maximum variation of pressure and inlet flow and under normal conditions will be significantly less.

Cartridge only Flow - L/min (21,8 cSt oil @ 49°C) 50 100 150

800

A

Pressure drop - psi

700

B

C

200

D

50 E

600

F

500

30

400 300

20

200

10

100 0

40

Pressure drop - bar

Description

0

5

10 15 20 25 30 35 40 Flow - USgpm (105 SUS oil @ 120°F)

45

50

Flow Division

(See model code position 5) A - 2* spool B - 3* spool C - 4* spool

D - 5* spool E - 6* spool F - 8* spool

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-590.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

FDC1-16 - Flow Divider/Combiner Pressure compensated, spool type Up to 178 L/min (47 USgpm) • 210 bar (3000 psi)

Model Code

FDC1 – 16 1

1 Function FDC1 - Flow divider/combiner

2

(V) – *** – ** – 00 3

4

16 - 16 size

4 Port Size Port Size

0 Cartridge only 12T SAE 12 6B 3/4" BSPP See section J for housing details.

6

5 Flow Divisions (Ratios)

3 Seals Blank - Buna-N V - Viton®

2 Size

Code

5

Housing Number

Aluminium Light Duty 566200 02-175468

Code

Flow Division %

Rated Inlet Flow

22 28 33 36 43 44 46 55 62 63 64 66 82 84 88

Port 4 50 20 50 33 57 50 40 50 75 67 60 50 80 67 50

L/min

(USgpm)

045,6 114,0 068,0 098,0 079,0 090,0 114,0 114,0 090,0 098,0 114,0 132,0 114,0 132,0 178,0

(12) (30) (18) (26) (21) (24) (30) (30) (24) (26) (30) (35) (30) (35) (47)

Port 2 50 20 50 67 43 50 60 50 25 33 40 50 20 33 50

6 Special Features 00 - None (Only required if valve has special features, omitted if “00”.) Dimensions

mm (inch)

Torque cartridge in aluminum housing to 108–122 Nm (80–90 ft lbs)

H

Cartridge Only Basic Code FDC1-16

13,0 (0.51)

38,1 (1.50) hex

1.312"-12 Thd. 4 104,8 (4.12)

3

2

Ø25,37 (0.999) Ø26,95 (1.061) Ø28,55 (1.124)

Notes: Port 1, unused, blocked by blind cavity. Minimum inlet flow should not be less than 1/4 of maximum inlet flow for a given code.

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-591.A

FDC11-16 - Flow Divider/Combiner Pressure compensated, spool type Up to 140 L/min (37 USgpm) • 350 bar (5000 psi)

2

4

Operation

Features spool to move and close the radial holes in the sleeve until equilibrium is restored. In the reverse direction the spools close together and regulate the flow in through the radial ports.

Inlet flow passes through the two matched orifices in the spools, through the spools and out of the radial holes in the sleeve. The matched orifices and the compensating springs ensure that the flow is divided equally, excess flow in either direction causes the

3

Sectional View

One valve synchronizes in both directions. Matched spools give high accuracy under load and pressure imbalance conditions. Cartridge construction gives versatility of application. A valve may be fitted into a line body, a custom designed Hydraulic Integrated Circuit or other hydraulic equipment.

Performance Data Ratings and Specifications

4

3

Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F) Typical application pressure (all ports) 350 bar (5000 psi) Cartridge fatigue pressure (infinite life) 350 bar (5000 psi) Rated inlet flow See model code Temperature range -40° to 120° C (-40° to 248° F) Cavity C–16–4 Fluids All general purpose hydraulic fluids such as MIL–H–5606, SAE 10, SAE 20, etc. Filtration Cleanliness code 18/16/13 Standard housing materials Aluminum or steel Weight cartridge only 0,35 kg (0.78 lbs) Seal Kits 889634 (Buna–N) 889638 (Viton®) Viton is a registered trademark of E.I. DuPont

2

Description

1

This range of flow divider/combiner valves gives division of input flow into two equal parts and re-combination of flow in the reverse direction. Pressure compensation ensures that whether dividing or combining, equal flow is maintained over a wide range of pressure variation. A typical use of these valves is to divide a pump flow to operate two actuators (which may be under different load conditions and at different pressures) and to re-combine the return flows to synchronize actuator movement. Flow variation is within ±10% with the maximum variation of pressure and inlet flow and under normal conditions will be significantly less.

Pressure Drop

Cartridge only 500 D

400 Pressure Drop (psi)

H

C

B

A

300 200 100 0

0

Flow Division A - 66 B - 44

5

10

15

20 25 Flow (gpm)

30

35

40

C - 33 D - 22

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-600.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

FDC11-16 - Flow Divider/Combiner Pressure compensated, spool type Up to 140 L/min (37 USgpm) • 350 bar (5000 psi)

FDC11 – 16

Model Code

1 1 Function

(V) – **** – ** – 00

2

3

4

Blank - Buna-N V - Viton®

2 Size 16 - 16 size

4 Port Size Code

Port Size

A12T SAE 12 A6B 3/4" BSPP A4G 1/2" BSPP A6G 3/4" BSPP A10H SAE 10 A12H SAE 12 S4G 1/2" BSPP S6G 3/4" BSPP S10T SAE 10 S12T SAE 12 See section J for housing details.

Dimensions

mm (inch)

Housing Number

Aluminium 20785* 02-186592* 30706 30708 30707 30709

6

5 Flow Divisions (Ratios)

3 Seals

FDC11 - Flow divider/combiner

5

Steel

Code

Flow Division%

Rated Inlet Flow

66 44 33 22 64 45 62 26 42 24

Port 4 50 50 50 50 60 40 75 25 67 33

L/min

(USgpm

133,0 114,0 083,6 057,0 140,6 140,6 114,0 114,0 83,6 83,6

(35) (30) (22) (15) (37) (37) (30) (30) (22) (22)

Port 2 50 50 50 50 40 60 25 75 33 67

6 Special Features 00 - None (Only required if valve has special features, omitted if “00”.)

02-175143 02-175144 02-175141 02-175142

Torque cartridge in aluminum housing to 108–122 Nm (80–90 ft lbs)

Cartridge Only Basic Code FDC11-16

12,7 (0.50)

H Installation Drawing 12.7 (0.501)

54 (2.12)

25.4 (1.00) 4

120.7 (4.75) 139.7 (5.50)

2 1

25.4 (1.00) 50.8 (2.000)

12.7 (0.50)

82.5 (3.25)

3

101.6 (4.00)

2 X Ø10.31 (0.406) 76.2 (3.000)

25.4 (1.00)

102,4 (4.03) Notes: Port 1, unused, blocked by blind cavity. Minimum inlet flow should not be less than 1/4 of maximum inlet flow for a given code.

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-601.A

2CFD50 - Flow Divider/Combiner Pressure compensated, spool type Up to 40 L/min (10.5 USgpm) • 350 bar (5000 psi)

2

4

Features

Operation Inlet flow passes through the two matched orifices in the spools, through the spools and out of the radial holes in the sleeve. The matched orifices and the compensating springs ensure that the flow is divided equally, excess flow in either

3

Sectional View

direction causes the spool to move and close the radial holes in the sleeve until equilibrium is restored. In the reverse direction the spools close together and regulate the flow in through the radial ports.

One valve synchronizes in both directions. Matched spools give high accuracy under load and pressure imbalance conditions. Cartridge construction gives versatility of application. A valve may be fitted into a line body, a custom designed Hydraulic Integrated Circuit or other hydraulic equipment.

Performance Data Ratings and Specifications

Outlet (4)

Inlet (3)

Outlet (2)

Up to 40 L/min (10.5 USgpm) 350 bar (5000 psi) All working parts hardened and ground steel. Zinc plated external steel body Standard aluminum (up to 210 bar*) add suffix “377” for steel option Unrestricted A12744 (See Section M) 34 Nm (25 lbs ft) 2CFD50 0.10 kg (0.23 lbs) 2CFD55 0.44 kg (0.98 lbs) SK1065 (Nitrile) SK1065V (Viton®) Up to 40 L/min (10.5 USgpm) -30˚ to +90˚C (-22˚ to +194˚F) 50 to 500 cSt

Viton is a registered trademark of E.I. DuPont

Description

Pressure Drop

750

0

10

Flow - L/min 20

30

40 7-20

3.3-10

600

40

450

30

300 150 0

50

20 15-40

10

2-5 0

2.5

5 Flow - US gpm

7.5

10

Pressure - bar

This range of flow divider/ combiner valves gives division of input flow into two equal parts and re-combination of flow in the reverse direction. Pressure compensation ensures that whether dividing or combining, equal flow is maintained over a wide range of pressure variation. A typical use of these valves is to divide a pump flow to operate two actuators (which may be under different load conditions and at different pressures) and to re-combine the return flows to synchronize actuator movement. Flow variation is within ±10% with the maximum variation of pressure and inlet flow and under normal conditions will be significantly less.

Pressure - psi

H

Figures based on oil temp at 40˚ and viscosity at 40 cSt Rated flow Max pressure Cartridge material Body material Mounting position Cavity number Torque cartridge into cavity Weight Seal kit Recommended filtration level Operating temp Nominal range

0

Note: When used on cylinders size to suit the return flow rate.

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-610.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

2CFD50 - Flow Divider/Combiner Pressure compensated, spool type Up to 40 L/min (10.5 USgpm) • 350 bar (5000 psi)

Model Code

2CFD**– 4W – 40 1

1 Function 2CFD50 - Cartridge only 2CFD55 - Cartridge and body

2

3

S 4 3

2 Port Size Code

Port Size

Housing Number - Body Only

Omit Cartridge only 3W 3/8" BSP inlet and outlet 4W 1/2" BSP inlet and outlet 8T-6T 1/2" SAE inlet and 3/8" SAE outlet

Aluminium

Steel

B19187 B20816 B19185

B21935

See section J for housing details.

Seals

S - Nitrile (for use with most industrial hydraulic oils) SV - Viton (for high temperature & most special fluid applications)

7 Capacity (Input) 5 - 2-5 L/min (0.5-1.3 USgpm) 10 - 3.3 - 10 L/min (0.9-2.6 USgpm)

20 - 7-20 L/min (1.8-5.3 USgpm) 40 - 15-40 L/min (4.0-10.5 USgpm)

Other terminations available on request. Dimensions

mm (inch) Cartridge Only Basic Code 2CFD50

Complete Valve 3/8", 1/2" Ports Basic Code 2CFD55

7.50 (0.30)

82.60 (3.25)

25.4 A/F

7/8”-14-UNF-2A

63.00 (2.48)

6.40 (0.25)

72.10 (2.84) 34.50 (1.36)

H

31.80 (1.25) 16.00 (0.63)

3 31.80 (1.25)

50.80 (2.00) 2

4

7.10 (0.28)

18.50 (0.73)

63.50 (2.50)

50.50 (1.99) 90 (3.54) approx

Notes: For applications above 210 bar (3000 psi), please consult our technical department or use the steel body option.

Notes: Blocking one leg will result in a large reduction in flow from the other. Valves with higher working pressures are available. Contact main office for details.

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-611.A

2CFD200 - Flow Divider/Combiner Pressure compensated, spool type Up to 220 L/min (58 USgpm) • 280 bar (4000 psi)

Features

Operation

2

4

Inlet flow passes through the two matched orifices in the spools, through the spools and out of the radial holes in the sleeve. The matched orifices and the compensating springs ensure that the flow is divided equally, excess flow

3

Sectional View

in either direction causes the spool to move and close the radial holes in the sleeve until equilibrium is restored. In the reverse direction the spools close together and regulate the flow in through the radial ports.

One valve synchronizes in both directions. Matched spools give high accuracy under load and pressure imbalance conditions. Cartridge construction gives versatility of application. A valve may be fitted into a line body, a custom designed Hydraulic Integrated Circuit or other hydraulic equipment.

Performance Data Ratings and Specifications

Figures based on an oil temp at 40˚C and of 32 cSt (150 SUS) Rated Flow Ratio division Maximum pressure Cartridge material Body material Mounting position Cavity Number Torque cartridge into cavity Weight Seal kit number Recommended Filtration Level Temperature range Nominal range

Outlet (3)

Inlet (2)

Outlet (1)

H

Up to 220 liters/min (58 USgpm) 50/50 standard 280 bar (4000 psi) Working parts hardened & ground steel. Zinc plated external steel body Aluminum (up to 210 bar*) Add suffix “377” for steel option Unrestricted CVB-42-04-0 (See Section M) 150 Nm (110 ft lbs) 2CFD200: 0,78 kg (1.72 lbs) 2CFD250: 2,50 kg (5.50 lbs) SK597 (Nitrile), SK597V (Viton®) BS5540/4 Class 18/13 –30° to +90° C (–22° to 194° F) 5 to 500 cSt

Viton is a registered trademark of E.I. DuPont

Description

464 406 348 290 232 174 116 58 0

0

50

Flow - L/min 100 150

200

30-95 52-150

0

13

26 39 Flow - US gpm

250

32 28 24 20 16 80-220 12 8 4 0 52 65

Pressure - bar

Pressure - psi

Pressure Drop

This range of flow divider/ combiner valves gives division of input flow into two equal parts and re-combination of flow in the reverse direction. Pressure compensation ensures that whether dividing or combining, equal flow is maintained over a wide range of pressure variation. A typical use of these valves is to divide a pump flow to operate two actuators (which may be under different load conditions and at different pressures) and to re-combine the return flows to synchronize actuator movement. Flow variation is within ±10% with the maximum variation of pressure and inlet flow and under normal conditions will be significantly less.

Note: When used on cylinders, size to suit the return flow rate.

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-620.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

2CFD200 - Flow Divider/Combiner Pressure compensated, spool type Up to 220 L/min (58 USgpm) • 280 bar (4000 psi)

Model Code

2CFD*** – 8W-6W – 95 1

1

Function

2CFD200 - Cartridge only 2CFD250 - Cartridge & body

2

S

3

4

2 Port Size Code

3

Port Size

Housing Number - Body Only

Omit Cartridge only 8W-6W 1" BSP inlet, 3/4" BSP outlet 10W-8W 1 1/4" BSP inlet, 1" BSP outlet 16T-12T 1" SAE inlet and 3/4" SAE outlet 20T-16T 1-1/4" SAE inlet and 1" SAE outlet

Aluminium C12320 B7666 B10710 B10711

Steel

B9075 B11819

95 - 3  0-95 L/min (7.9-25 USgpm) 150 - 52-150 L/min (13.7-40 USgpm) 220 - 80-220 L/min (21-58 USgpm)

4

See section J for housing details.

Capacity (input)

Seals

S - Nitrile (for use with most industrial hydraulic oils) SV - Viton (for high temperature & most special fluid applications)

Dimensions mm (inch) Complete Valve 3/4", 1", 1 1/4" Ports Basic Code 2CFD250

Cartridge Only Basic Code 2CFD200

14.6 (0.57) max

46.0A/F

175.0 (6.89) 110.0 (0.43) 33.0 (1.30)

31.8 (1.25)

63.5 (2.50)

H

M42.0 x 2.0-6g 3

1

101.6 (4.00)

Outlet (3)

2

89.0 (3.50) 66.0 (2.60)

151.0 (5.94) max

Inlet (2)

50.8 (2.00)

30.0 (1.18)

187.5 (7.38) max 2 holes Ø10.5 (0.41) thro’

Outlet (1) Note: Blocking one leg will result in a large reduction in flow from the other. Valves with higher working pressures are available. Contact factory for details.

Note: For applications above 210 bar (3000 psi) please consult our technical department or use the steel body option

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-621.A

FDC1-20 - Flow Divider/Combiner Line mounted, pressure compensated, spool type Up to 141 L/min (37 USgpm) • 210 bar (3000 psi)

3

2

Features

Operation Inlet flow passes through the two matched orifices in the spools, through the spools and out of the radial holes in the sleeve. The matched orifices and the compensating springs ensure that the flow is divided equally, excess flow

1

Sectional View

in either direction causes the spool to move and close the radial holes in the sleeve until equilibrium is restored. In the reverse direction the spools close together and regulate the flow in through the radial ports.

One valve synchronizes in both directions. Matched spools give high accuracy under load and pressure imbalance conditions.

Performance Data Ratings and Specifications

2

1

3

Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F) Typical application pressure (all ports) 210 bar (3000 psi) Cartridge fatigue pressure (infinite life) 210 bar (3000 psi) Rated inlet flow See model code Fluids All general purpose hydraulic fluids such as MIL–H–5606, SAE 10, SAE 20, etc. Filtration Cleanliness code 18/16/13 Standard housing materials Aluminum Weight cartridge only 2,6 kg. (5.75 lbs) Seal kits 889639 (Buna–N) 889643 (Viton®) Viton is a registered trademark of E.I. DuPont

H

Description

Pressure Drop

This range of flow divider/ combiner valves gives division of input flow into two equal parts and re-combination of flow in the reverse direction. Pressure compensation ensures that whether dividing or combining, equal flow is maintained over a wide range of pressure variation. A typical use of these valves is to divide a pump flow to operate two actuators (which may be under different load conditions and at different pressures) and to re-combine the return flows to synchronize actuator movement. Flow variation is within ±10% with the maximum variation of pressure and inlet flow and under normal conditions will be significantly less.

Cartridge only Inlet flow rate, port 1, - L/min (21,8 cSt oil @ 49°C) 0

100

200

300

Pressure drop - psi

A

25

300

20 B

200 C 100 D 0

0

20

40

60

80

15 10

Pressure drop - bar

30

400

5

100

Inlet flow rate, port 1, - USgpm (105 SUS oil @ 120°F)

Flow Division

(See model code position 5) A - 3* spool B - 4* spool

C - 6* spool D - 8* spool

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-630.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

FDC1-20 - Flow Divider/Combiner Line mounted, pressure compensated, spool type Up to 141 L/min (37 USgpm) • 210 bar (3000 psi)

Model Code

FDC1 – 20 1

1 Function FDC1 - Flow divider/combiner

2 Size 20 - 20 size

3 Seals Blank - Buna-N V - Viton®

2

(V) – *** – ** – 00 3

4

5

6

5 Flow Divisions (Ratios)

6 Special Features

Code

Flow Division%

Max

Inlet Flow

33 34 36 44 66 88

Port 3 50 43 33 50 50 50

L/min 114,0 83,6 57,0 140,6 140,6 114,0

(USgpm) (30) (22) (15) (37) (37) (30)

Port 2 50 57 67 50 50 50

00 - None (Only required if valve has special features, omitted if “00”.)

4 Port Size 16T - SAE 16 (light duty) 20T - SAE 20 (light duty) (Available as a complete assembly only.)

Dimensions

178,0 (7.00)

mm (inch) Complete Valve Basic Code FDC1-20 Torque cartridge in housing to 128–155 Nm (95–115 ft lbs)

152,4 (6.00)

12,7 (0.50)

H

63,5 (2.50) 31,7 (1.25)

Notes: Minimum inlet flow should not be less than 1/4 of maximum inlet flow for a given code.

2

12,7 (0.50)

31,7 (1.25)

3

31,7 (1.25)

104,0 (4.10)

101,6 (4.00) 76,2 (3.00)

50,8 (2.00) 1

44,4 (1.75) 76,2 (3.00)

44,4 (1.75)

Ø10,0 (0.406 thru) (3 plcs.)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-631.A

FDC3-16 - Flow Divider/Combiner Pressure compensated, spool type, posi-traction Up to 152 L/min (40 USgpm) • 210 bar (3000 psi)

2

4

3

Sectional View

Operation

Features

This valve is used in the dividing mode. It will take the inlet flow (port 3) and split the flow to ports 2 and 4. In the combining mode this valve will take the inlet flows from ports 2 and 4 and combine them into port 3 according to the ratio specified.

Hardened and ground and honed working components. Cartridge construction for maximum mounting flexibility.

Performance Data Ratings and Specifications

4

3

Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F) Typical application pressure (all ports) 210 bar (3000 psi) Cartridge fatigue pressure (infinite life) 210 bar (3000 psi) Rated inlet flow See model code, item Temperature range -40° to 120° C (-40° to 248° F) Cavity C–16–4 (See Section M) Fluids All general purpose hydraulic fluids such as: MIL–H–5606, SAE 10, SAE 20, etc. Filtration Cleanliness code 18/16/13 Standard housing materials Aluminum Weight cartridge only 0,35 kg. (0.78 lbs) Seal kits 889634 (Nitrile) 889638 (Viton®) Viton is a registered trademark of E.I. DuPont

2

H

1 Pressure Drop

This is a pressure compensated flow divider / combiner posi-traction screw in cartridge valve. This is ideal for use in transmission systems where the turning circle requires one wheel to go faster than the other or where rapid make up is required between cylinders at the end of stroke.

Cartridge only Flow - L/min (21,8 cSt oil @ 49°C) 50 100 150

800

A

700 Pressure drop - psi

200 50

B

600

C

E

D

40

F

500

30

400 300

20

200

10

100 0

Pressure drop - bar

Description

0

5

10

15

20

25

30

35

40

45

50

Flow - USgpm (105 SUS oil @ 120°F)

Flow Division

(See model code position 5) A - 22 spool B - 33 spool C - 44 spool

D - 55 spool E - 66 spool F - 88 spool

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-640.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

FDC3-16 - Flow Divider/Combiner Pressure compensated, spool type, posi-traction Up to 152 L/min (40 USgpm) • 210 bar (3000 psi)

Model Code

FDC3 – 16 1

1 Function FDC3 - Posi-traction valve

2

(V) – ** – ** – 00 3

4

Code

22 33 44 55 66 88

16 - 16 size

4 Port Size Port Size

0 Cartridge only 12T SAE 12 6B 3/4" BSPP

Housing Number

Aluminium

mm (inch)

Flow Division %

Port 4 50 50 50 50 50 50

Port 2 50 50 50 50 50 50

Max

Inlet Flow

L/min 57,0 76,0 106,4 126,2 152,0 228,0

(USgpm) (15) (20) (28) (34) (40) (60)

6 Special Features

566200 02-175468

00 - None (Only required if valve has special features, omitted if “00”.)

See section J for housing details.

Dimensions

6

5 Flow Divisions

3 Seals Blank - Buna-N V - Viton®

2 Size

Code

5

Torque cartridge in aluminum housing to 108–122 Nm (80–90 ft lbs)

H

Cartridge Only Basic Code FDC3-16

13,0 (0.51)

38,1 (1.50) hex 1.312 "?-12 Thd. 4 104,8 (4.13)

3

2

Ø25,37 (0.999) Ø26,95 (1.061) Ø28,55 (1.124)

Notes: Port 1, unused, blocked by blind cavity. Minimum inlet flow should not be less than 1/4 of maximum inlet flow for a given code.

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-641.A

FDC3-20 - Flow Divider/Combiner Pressure compensated, spool type, posi-traction Up to 570 L/min (150 USgpm) • 210 bar (3000 psi)

3

2

1

Sectional View

Operation

Features

This valve is used in the dividing mode. It will take the inlet flow (port 3) and split the flow to ports 2 and 4. In the combining mode this valve will take the inlet flows from ports 2 and 4 and combine them into port 3 according to the ratio specified.

One valve synchronizes in both directions. Matched spools give high accuracy under load and pressure imbalance conditions.

Performance Data Ratings and Specifications

2

1

3

Performance data is typical with fluid at 21,8 cST (105 SUS) and 49°C (120°F) Typical application pressure (all ports) 210 bar (3000 psi) Cartridge fatigue pressure (infinite life) 210 bar (3000 psi) Rated inlet flow See model code, item Temperature range -40° to 120° C (-40° to 248° F) Cavity C–16–4 (See page 70) Fluids All general purpose hydraulic fluids such as MIL–H–5606, SAE 10, SAE 20, etc. Filtration Cleanliness code 18/16/13 Standard housing materials Aluminum Weight cartridge only 0,35 kg. (0.78 lbs) Seal kits 889634 (Nitrile) 889638 (Viton®) Viton is a registered trademark of E.I. DuPont

H

Pressure Drop

Inlet flow rate, port 1, - L/min (21,8 cSt oil @ 49°C) 0

100

200

400 350 300 250 200 150 100 50 0

300

400

500

600 30

C

A

D

B

25 20 15 10

Pressure drop - bar

This is a pressure compensated flow divider / combiner posi-traction valve. This is ideal for use in transmission systems where the turning circle requires one wheel to go faster than the other or where rapid make up is required between cylinders at the end of stroke.

Pressure drop - psi

Description

5

0 20 40 60 80 100 120 140 Inlet flow rate, port 1, - USgpm (105 SUS oil @ 120°F)

Flow Division (See model code position 5) A - 33 spool B - 44 spool

C - 66 spool D - 88 spool

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-650.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

FDC3-20 - Flow Divider/Combiner Pressure compensated, spool type, posi-traction Up to 570 L/min (150 USgpm) • 210 bar (3000 psi)

Model Code

FDC3 – 20 1

1 Function FDC3 - Posi-traction valve

2 Size 20 - 20 size

3 Seal Material

(V) – *** – ** – 00

2

4

3

5

6

5 Flow Divisions (Ratios)

6 Special Features

Code

Flow Division%

Rated Inlet Flow

00 - None

33 44 66 88

Port 3 50 50 50 50



(Only required if valve has special features, omitted if “00”.)

Port 2 50 50 50 50

L/min 190,0 266,0 380,0 570,0

(USgpm) (50) (70) (100) (150)

Blank - Buna-N V - Viton®

4 Port Size 16T – SAE 16 (light duty) 20T – SAE 20 (light duty) (Available as a complete assembly only.)

Dimensions

mm (inch) Complete Valve Basic Code FDC3-20 Torque cartridge in housing to 128–155 Nm (95–115 ft lbs) Note: Minimum inlet flow should not be less than 1/4 of maximum inlet flow for a given code.

12,7 (0.50)

152,4 (6.00)

12,7 (0.50)

76,2 (3.0) 63,5 (2.50) 31,7 (1.25)

12,7 (0.50)

H

2

3

31,7 (1.25)

101,6 (4.00)

104,0 (4.10)

76,2 (3.00)

1

31,7 (1.25)

44,4 (1.75) 76,2 (3.00)

44,4 (1.75)

Ø10,3 (0.406 thru) (3 plcs.)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice. An Eaton Brand

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

H-651.A

- Additional products, product lines, and services offered by Eaton -

Custom Configurations

H

Custom Power Units •CustomDesignedtoyour •Installationservices specifications available •Upto5000hp,2000gpm

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

H-652.A

EATON Screw-In Cartridge Valves E-VLSC-MC001-E December 2009

An Eaton Brand

Flow Controls.pdf

up to 350 bar (5000 psi) and 350 L/min (92 USgpm). Page 1 of 124 ... FR1-16 C-16-2 114 (30) 210 (3000) H-120. FR1-20 C-20-2 227 (60) ..... Flow Controls.pdf.

14MB Sizes 0 Downloads 230 Views

Recommend Documents

BGP Type Flow Spec BGP Flow Provider Flow Spec BGP ... - Groups
BGP Type Flow Spec. BGP Flow Provider. Flow Spec. BGP Flow web resource. (New). BGP Flow. Decoder. (New). BGP. Driver. (New). ONOS. Flow Rule.

Multi-flow Attacks Against Network Flow Watermarking Schemes
We analyze several recent schemes for watermarking net- work flows based on splitting the flow into intervals. We show that this approach creates time dependent correla- tions that enable an attack that combines multiple wa- termarked flows. Such an

Turbulent Laser - Flow Visualization
The image was cropped in Photoshop and the contrast along with the sharpness was increased. The color curves were also used to bring out the green in the ...

Buoyancy - Flow Visualization
Feb 9, 2011 - water, 1000 kg/m3, and carbon dioxide gas,1.95 kg/m3 at standard temperature and pressures[1][3]. The Photo was taken looking from the bottom of the class upward and taken once the water temperature fell below 9⁰C since no condensatio

Networked Flow
problem solving skills. Drawing on recent advances in group creativity research, social cognition and network science, we propose a theoretical framework for ...

Home flow Accounts
Module. Android. Command. Reciever. Notification. Sender. Communicating Module. Virtual Functions. Arduino. Function. Statements. Flow Manager. Data.

Shadow packet flow - GitHub
Applications call sendto to place packet in socket buffer. Interface takes packet from socket buffer and places it in discrete event queue. Packets taken from ...

knowledge flow
scientific articles are objective data used, for example, by ... scientists, scientific articles, and journals [5]. .... extracting and mining from scientific data, activities,.

Couette flow
1Department of Computer Science, Technion, Haifa 3200, Israel. 2IGPP ..... By definition, the cyclonicity of the flow is determined by the sign of (Ω2) at r = ¯r. ..... grid the smallest (in absolute value) eigenvalues of the matrices, obtained by

Turbulent Laser - Flow Visualization
course. The objective of the photo was to capture the cross section of a ... The image was cropped in Photoshop and the contrast along with the sharpness was.

knowledge flow
link to anything” [3]—but citation is not. ... knowledge, and attracting new comers in their social networks. People and journals ... needs a semantic space of three.

PLC Flow Chart.pdf
Page 1 of 1. Page 1 of 1. PLC Flow Chart.pdf. PLC Flow Chart.pdf. Open. Extract. Open with. Sign In. Main menu. Displaying PLC Flow Chart.pdf. Page 1 of 1.

Stock–flow matching
Available online 20 February 2010 ... This paper develops and quantifies the implications of the stock–flow matching ... Meetings, the 2006 NBER Summer Institute, the 2007 UCSB–LAEF Conference on Trading Frictions in Asset Markets,.

Flow Simulation 2009 Tutorial
Analyze a Design Variant in the Flow Simulation Application . ...... name after the value and Flow Simulation will automatically convert the entered value to the SI ...

Optical Flow Approaches
Feb 17, 2008 - Overall, both MEEG native or imaging data may be considered as .... 2006]). We wish to define velocity vectors as the dynamical signature of ...

Nex-Flow-catalog.pdf
There was a problem previewing this document. Retrying... Download. Connect more apps... Try one of the apps below to open or edit this item.

Capital Flow Deflection
1 Introduction. What type of multilateral institutions do countries need to govern international capital flows? As the size and volatility of capital flows, namely to developing coun- .... surges. Notwithstanding the strength of capital flow deflecti

Karman Vortex Street - Flow Visualization
Mar 13, 2011 - . [3] Espeyrac, Lionel. "Strouhal Instability." Physics Knowledge. Physics Knowledge, 2009. Web. 13 Mar.

DOK Flow Chart.pdf
Page. 1. /. 1. Loading… Page 1 of 1. Page 1 of 1. DOK Flow Chart.pdf. DOK Flow Chart.pdf. Open. Extract. Open with. Sign In. Main menu. Displaying DOK Flow Chart.pdf. Page 1 of 1.

Figure 1: BPhD Flow Chart
Other Entitlements/Grants. Monitoring/Evaluation of the activities of the PhD/Post-. PhD Recruit. NEXT? Academic Personnel (and. Research) Committees review & endorse recommendation to the. Chancellor. Submission of application to. CU/CUs. CUs and th

Optical Flow Approaches
Feb 17, 2008 - properties of brain activity as revealed by these techniques. ..... As a matter of illustration and proof of concept, we will focus on the possible ..... advanced model for global neural assemblies may be considered in future ...

debris flow sensor.pdf
There was a problem previewing this document. Retrying... Download. Connect more apps... Try one of the apps below to open or edit this item. debris flow ...