Earth leakage and overloads short-circuit protection with self-reclosing
P 2
P.2.01 GB
P.2 Earth leakage and overload/short circuit protection systems with self-reclosure
CONTENTS Associated breaking element Earth leakage protection systems with self-reclosure
Page 3-4
Parameters related to self-reclosure relays
5
Protection and earth leakage reclosure
6
REC, built in system
Built in
7
WRU-25 RA / WRU-35 RA, Relays with built-in transformer
9
RGU-RA / RGU-10 RA / RGU-10C RA, Relays with external transformer
10
WG-35 / WG-70 / WG-105 / WG-140 / WG-210 WRU-25 2R / WRU-RM / WRU-RT, other relays with different functions
Contactor
10 11
GU72-D RA / CBS-8
12
CBS-8
13
Overload and earth leakage protection / earth leakage reclosure WRKRT-25 T / WRKRT-25 N
14 MCB
15
Overload and earth leakage protection and reclosure WRU 25 RA-MT, Relays with built-in transformer RGU-10 RA, Relays with external transformer
17 MT
18
WRT-6-25, other relays with different functions
19
RGMT, other relays with different functions
20
Earth leakage and overvoltage protection / overload and earth leakage reclosure RGST-2 / RGST-4
21 MT
Overload reclosure
21 22
RRM-P, RRM-C
MT
22
Breaking elements MCB-P / MCB-T circuit breaker
23
MT motorised overload device
24
MT-FDE, MT-FEE motorised overload device
25
Accessories
26
Dimensions / Connection
27-32
Protección y reconexión diferencial
Protección magnetotérmica y diferencial y reconexión diferencial
Protección y reconexión magnetotérmica y diferencial
Reconexión magnetotérmica
P2-2
P.2 Earth leakage and overload/short circuit protection systems with self-reclosure
Earth leakage protection systems with self-reclosure Given the necessity and obligation of ensuring effective protection to both people and goods and the complexity of installations requiring continuous supply of electrical energy without removing earth leakage and overload protection, CIRCUTOR has developed a range of equipment which allows safety to be matched with continuous service. Self-reclosure is the ideal solution for installations requiring continuous supply of electrical energy without the usual maintenance staff: • • • • • • • • •
Rural installations Refrigerated chambers Public lighting Mobile telephone repeaters Traffic lights Tunnel lighting ATM’s Cable television etc.
In every self-reclosure system the type of protection to be reconnected and under which conditions must be known. Self-reclosure systems operate under: • Earth leakage current (differential) • Earth leakage current (differential) + overload and short-circuit (overload)
Elements comprising a self-reclosure system
TRANSFORMER
Signal handling + measuring and trip relay
Monitored breaking device
Differential transformer
El transformador diferencial detecta la Fuga a tierra. Éste puede estar incorporado en el relé o ser exterior a él.
Self-reclosure relay Self-reclosure relays offer additional benefits (self with closure, overload or short-circuit protection), to the reliability and safety shown by Series U earth leakage protection. Its functions are: • Fault detection (earth leakage or overload) via a signal generated by the transducer • Analysing if this fault should set off an alarm, with regard to the different preset parameters • Operating on a power device which connects – disconnects the load from the system
P2-3
P.2 Breaking element
Earth leakage and overload/short circuit protection systems with self-reclosure
The breaking element always operates as a power switch which supports the line power to be protected and is outside the relay. The breaking elements which may be associated with self-reclosure relays are: • Motorised overload/short-circuit device (MT series) (see page 24) • Contactor • Circuit breaker with remote-control (MCB) (see page 23), with the double function of overload/short-circuit protection and contactor (the conduct of function is bistable) The features which the breaking elements must know are: • • • • •
Rated current (in the contactors) Rated currents and the protection thermal curve (in overload/short-circuit devices) Features of the command inputs in the operating element Cut off power NA or NC auxiliary signalling of the status of the breaking device
Reclosure
Protection
Earth leakage
Page Earth leakage switch reconnector
6
Differential relay + contactor
8
Differential relay + MCB circuit breaker
14
Differential relay + MT overload device
16
Differential relay + FDE overload device
18
Earth leakage
Earth leakage Overload and Earth leakage Overload and earth leakage
P2-4
Earth leakage + overvoltage
Overload and earth leakage
Differential relay + MT overload device
21
Overload
Overload
RRM relay + MT / FDE overload device
22
P.2 Earth leakage and overload/short circuit protection systems with self-reclosure
Parameters related to self-reclosure relays Relay status indication Indicators associated with protection are different for instant tripping and sealing. Indications are from the same relay (LED) and as an option may be through auxiliary contacts. Another type of display, depending on the relay, is the instant leakage value and the total number of reclosures.
Rated tripping point for protection Typical values: Earth leakage protection 30 mA – 3 A Overload protection 6 A – 63 A.
Timing (delay) for reclosure Minimum time which the earth leakage must last to cause the relay to trip. Typical values. 20 ms – 1 s
Relay power supply and tolerance The reclosure relays automatically require a permanent auxiliary power supply to be able to manage the automatic connection. Standard value: 230 V a.c..± 15 %. Optional 48 V a.c., 110 V a.c., 400 V a.c..
Time between reclosures This is the time the relay takes from the trip to reclosing. This time may be lineal or exponential.
Output relay Number of relays with output contact sealing NA or NC
Number of different reclosures / Number of types of reclosure Each relay allows a maximum number of the closures before being sealed. This meter may automatically put on zero if the number maximum number of reclosures has not been exceeded during a preset time (return to zero a time for the reclosure meters). This number will be different for the type of reclosure.
Return to zero time for the reclosure meters In order to avoid tripping being mounted up which do not belong to the same fault, a return to zero time for the reclosure meter may be set. This time restarts after each reclosure whenever a maximum number of reclosures is not exceeded. Example: The WRU 25 RA relay has a maximum number of six reclosures before being sealed. In an installation where the transient earth leakage fault lasts for 50 s, the relay will trip 4 times and reclose 3 times (8 s + 16 s + 30 s). While the third reclosure is being timed the fault disappears so the relay stays on ON. At this time the meter returns to zero reconnections. The RESET option restarts the relay returning the reclosure meters to zero.
On site and remote Test and Reset (using the keypad) The automatic earth leakage reclosure relays offer the same benefits as the U series earth leakage protection, among which is the option to check the proper operation of the relay using on-site TEST and RESET using the keypad on the relay itself and remotely using the specific inputs. The test is interpreted by the relay as an external leak. The relay will reconnect after a given time and increase the internal reclosure meter. The reset option restarts and relay return in the reclosure meters to zero.
P2-5
P.2 Earth leakage and overload/short circuit protection systems with self-reclosure
PROTECTION AND EARTH LEAKAGE RECLOSURE AUTOMATIC EARTH LEAKAGE RECONNECTOR SWITCH - REC
In the majority of cases (95 %), when the earth leakage protection is tripped, a simple manual reconnection solves the problem because there is no permanent leakage. If there is no REC automatic reconnector, this simple, manual reconnection operation may become a serious problem if there is nobody nearby or if the earth leakage trip is not known: • Food rots in the fridge • Plants wither through lack of watering • Swimminutesg pool water goes bad • The alarm system does not protect • The tilting garage door does not work • The farm may suffer serious damage • There is no mobile telephone coverage (fault with telephone repeater) • The ATM does not work • Streets and squares remain in the dark • Traffic lights stop working • etc.
t
h
e
Pure earth leakage switch with automatic resetting Terminals for the command line: N - L: 230 V AC power supply LI: external reclosure order (optional)
Free of power output indicates in earth leakage status
Motor
Earth leakage
2 or 4 pole breaking element
Manual switch (yellow lever): position I: automatic operation position 0: self-reclosure not permitted
The reclosure metre returns to zero if: • Leakage is not permanent • It always reconnects manually Number of reclosures
Time between reclosures
6
20, 30, 60, 120, 600 s
Hole for padlock Option for manual locking with padlock
Earth leakage protection required by current legislation protects people but unforeseen that trips made provoke a fault with the electrical supply in important installations. REC from CIRCUTOR is safe, easy to install, economic or will guarantee self-reclosure in your installation whenever the leakage is not permanent.
P2-6
P.2
REC 2 Poles
Poles
Class
In (A)
2
AC
40
30 mA
REC 2-40-30
P24111
2
AC
40
300 mA
REC 2-40-300
P24121
2
AC
63
30 mA
REC 2-63-30
P24114
2
AC
63
300 mA
REC 2-63-300
P24124
4
AC
40
30 mA
REC 4-40-30
P24112
4
AC
40
300 mA
REC 4-40-300
P24122
4
AC
63
30 mA
REC 4-63-30
P24113
4
AC
63
300 mA
REC 4-63-300
P24123
Sensitivity
Type
Earth leakage and overload/short circuit protection systems with self-reclosure
REC
Code
On request Class A
REC 4 Poles
Reclosure
Protection
Earth leakage reclosure
Earth leakage protection Electromechanical AC or A, according to type
Class Measuring
Number of reclosures
6
Time between reclosures
10, 20, 30, 60, 120, 600 s
Instant value 30 mA or 300 mA (according to type)
Sensitivity I∆n Delay
Same as last time between reclosures (For example: final reclosure on the third attempt → return to the zero time after 30 s)
Return to zero time for partial meter
Fixed at 20 ms
Diferential transformer
Built in
Test
Via built in button
Reset
Manual, by lifting the lever
Asociated breaking element In and number of poles
Safety seal
Using disconnection lever
Remote signalling (outputs)
Voltage free switched relay for status indication
Remote-control (inputs)
External reset using button
Built in In 40 A or 63 A , 2 or 4 poles
Breaking element control
Electromechanical relay
Features 2 poles
4 poles
Electrical features Auxiliary power supply Outputs contacts
230 / 400 V a.c., 50...60 Hz 2 A maximum for 250 V a.c. / 24 V d.c.
Operating temperature
-25 ºC / + 55 ºC
Assembly features Mounting Dimensions Weight Protection grade Standards
DIN rail 5 modules (90 x 90 mm)
7 modules (125 x 90 mm)
560 g
693 g IP 40
IEC 61008-1, IEC 755, IEC 255-5
P2-7
P.2 Earth leakage and overload/short circuit protection systems with self-reclosure
PROTECTION AND EARTH LEAKAGE RECLOSURE INSULATED SWITCH WITH SETTABLE SENSITIVITY AND DELAY
Switch formed by: Earth leakage relay + contactor Class A insulated. High-frequency filtering
Leakage current level indicator via variable flashing
Settable delay
Settable sensitivity
Number of poles and line current defined by the contactor
Earth leakage protection + earth leakage reclosure
APPLICATIONS Street lighting
Office blocks
• Traffic lights • Car parks • Refrigerated chambers
P2-8
P.2
Class
In (A)
Poles
Useful diameter ∅ mm
I∆n or Sensitivity (A)
Delay (s)
Type
Earth leakage and overload/short circuit protection systems with self-reclosure
Earth leakage relay with built in transformer
Code
A
63 (*)
2, 3, 4
25
0,03...3
0,02...1
WRU-25 RA
P24211
A
125 (*)
2, 3, 4
35
0,03...3
0,02...1
WRU-35 RA
P24221
(*) According to contactor Number of reclosures
Time between reclosures (s)
WRU-25 RA
6
8,16,30,59,115,224
WRU-35 RA
6
8,16,30,59,115,224
Type
WRU-35 RA
+
Complete set formed by: Earth leakage relay + Contactor WRU-25 RA
Protection
Reclosure
WRU 25 RA
WRU 35 RA
WRU 25 RA Earth leakage reclosure
Earth leakage protection Class
Selectable 30 mA...3 A
Delay
Selectable 20 ms ... 1s Built in ∅ 25 mm
Test y Reset
In and number of poles
8, 16, 30, 59, 115, 224 s
Return to zero time for partial meter
Built in ∅ 35 mm
Via built in button
Associated breaking element
6
Time between reclosures
TRMS
Sensitivity I∆n
Differential transformer
No. of reclosures
A superinsulated
Measuring
15 minutes
Signalling in the relay – Presence of voltage indicator – Sealed reclosure – Indicates the presence of leakage current without reaching the trip point
LED
Contactor Defined by contactor used
Breaking element control
WRU 35 RA
1 switched relay
Remote signalling (outputs)
Leakage control signal (proportional alternating voltage)
Remote-control (inputs)
External test using button
Features WRU 25 RA
WRU 35 RA
Electrical features Auxiliary power supply Breaking element control contacts
230 V a.c. (± 20 %) 50...60 Hz 250 V a.c. / 8 A a.c.
Operating temperature
- 10 ºC / + 50 ºC
Mechanical features Mounting Dimensions Weight Protection grade Standards
DIN rail 4 modules
6 modules
234 g
415 g
Terminals: IP20, Built in relay: IP41 IEC 61008-1, IEC 755, IEC 255-5
P2-9
P.2 Earth leakage and overload/short circuit protection systems with self-reclosure
Earth leakage relay with external transformer
I∆n (A)
Delay (s)
Communications
Number of reclosures
Breaking element control
Remote signalling
Type
Code
0,03...3
0,02...1
-
6
Switched relay
-
RGU-RA
P24311
0,03...30
0,02...10
-
Programmable
NA relay-Positive safety
Relay seal
RGU-10 RA
P24612
0,03...30
0,02...10
RS-485
Programmable
NA relay-Positive safety
-
RGU-10C RA
P24632
Selection of differential transformer according to rated line current
+
RGU-RA
WG-35
P10111
70 ∅
WG-70
P10112
105 ∅
WG-105
P10113
140 ∅
WG-140
P10114
210 ∅
WG-210
P10115
Reclosure
RGU-RA
RGU-10 RA
RGU-RA
Number of reclosures
A superinsulated
Measuring
TRMS
Time between reclosures
Selectable 30 mA...3 A
Programmable 30 mA...30 A
Selectable 20 ms ... 1s
Programmable 20 ms ... 1s Inverse curve: Instant or selective
6
Programmable: 0... 10
8, 16, 30, 59, 115, 224 s
Programmable: 1... 900 s
15 minutes
15 / 30 minutes
Return to zero time for partial meter Signalling in the relay
Differential transformer
External, Serie WG
Test y Reset
Via built in button
Associated breaking element
- Presence of voltage - Sealed reclosure - Indicates the presence of leakage current without reaching the trip point
LED
Contactor
In and number of poles
Defined by contactor used 1 switched relay
1 relay simple
LCD
Remote signalling (outputs)
-
Prealarm relay
Remote-control (inputs)
-
ON / OFF
RGU-10 RA
Electrical features
Breaking element control contacts
230 V a.c. (± 20 %) 50...60 Hz 250 V a.c. / 8 A.a.c
Operating temperature
250 V a.c. / 6 A a.c. -10 ºC / +50 ºC
Mechanical features Mounting Dimensions Weight
Presence of voltage One channel tripped Reclosure enabled Sealed status RS-485 Communications
-
RGU-RA
Auxiliary power supply
-
Display
Features
P2-10
RGU-10 RA
Earth leakage reclosure
Earth leakage protection Class
Breaking element control
30 ∅
Code
Complete set formed by: Earth leakage relay + Toroidal transformer + Contactor
Protection
Delay
Type
+
RGU-10-RA
Sensitivity I∆n
Useful diameter (mm)
DIN rail 4 modules
3 modules
261 g
236 g
Protection grade
Terminals: IP20, Built in relay: IP41
Standards
IEC 61008-1, IEC 755, IEC 255-5
P.2 Earth leakage and overload/short circuit protection systems with self-reclosure
Other earth leakage relays with different functions
Relays with built in transformer Useful diameter ∅ mm
I∆n (A)
Delay (s)
Number of reclosures
25
0,03...3
0,02...1
30
25
0,03...3
0,02...1
3
25
0,3...1
0,02
3
1 NC contact
Breaking element control
Remote signalling
Type
Code
Switched relay
-
WRU-RM
P24231
1 NA-SP contact
1 NA-SP contact
WRU-RT
P24431
1 NA contact
WRU-25-2R
P24412
Protection
WRU-25-2R
WRU-RM
WRU-RT
Earth leakage protection Class
A superinsulated
Measuring Sensitivity I∆n
TRMS Settable 300 mA ... 1 A
Delay
Selectable 30 mA ... 3 A
Fixed 20 ms
Selectable 20 ms ... 1 s
Differential transformer
Built in Ø 25 mm
Test y Reset
Via built in button
Associated breaking element
Contactor
In and number of poles
Defined by contactor used
Reclosure WRU-25-2R
WRU-RM
WRU-RT
Earth leakage reclosure Number of reclosures
31 st
Time between reclosures Return to zero time for partial meter
30 nd
1 at 2 min., 2 at 4 min., remainder every 6 min.
20 s, 40 s y las 28 remainder every 5 minutes
15 minutes
15 minutes
Features WRU-25-2R
WRU-RM
WRU-RT
Electrical features Auxiliary power supply Breaking element control contacts Operating temperature
230 V a.c. (± 20%) 50...60 Hz 250 V a.c. / 8 V a.c. -10 ºC / +50 ºC
Mechanical features Mounting Dimensions Weight Protection grade Standards
DIN rail 4 modules 234 g Terminals: IP20, Built in relay: IP41 IEC 61008-1, IEC 755, IEC 255-5
P2-11
P.2 Earth leakage and overload/short circuit protection systems with self-reclosure
Other earth leakage relays with different functions
Relés con transformador externo I∆n (A)
Delay (s)
Communications
Number of reclosures
Breaking element control
Remote signalling
Type
Code
0,03...3
0,02...1
-
6
Switched relay
-
GU72-D RA
P24321
0,03...30
0,02...10
RS-485
Prog.: 0...10
8 relays (independent)
Pre-alarm relay
CBS-8
P12811
Protection
GU-72 RA
CBS-8
Earth leakage protection Class
A superinsulated
Measuring
TRMS
Sensitivity I∆n
Selectable 30 mA...3 A
Delay
Selectable 20 ms ... 1 s
Differential transformer
0,03…6 A with external transformers WG/WGS 0,03…60 A with external transformers WGP/WGPS Programmable 0,20 ms ... 10 s Inverse curve: Instant or selective External, Serie WG
Test y Reset
Via built in button
Associated breaking element
Contactor
In and number of poles
Defined by contactor used
Reclosure GU-72 RA
CBS-8
Earth leakage reclosure No. of reclosures Time between reclosures Return to zero time for partial meter
6
Programmable
8, 16, 30, 59, 115, 224 s
Programmable
15 minutes
Programmable
Features RGU-RA
CBS-8
Electrical features Auxiliary power supply
230 V a.c. (± 20 %) 50...60 Hz
Breaking element control contacts
250 V a.c. / 8 A a.c.
Operating temperature
- 10 ºC / +50 ºC
Mechanical features Mounting Dimensions Weight Protection grade Standards
P2-12
Panel
DIN rail
72 x 72 mm
8 modules
349 g
609 g Terminals: IP20, Built in relay: IP41 IEC 61008-1, IEC 755, IEC 255-5
P.2 • • • •
8 earth leakage protection programmable relays, class A Frequency filtering Disconnection delay using inverse curve Independent programminutesg per channel
Earth leakage and overload/short circuit protection systems with self-reclosure
CBS-8
Reduction of unforeseen trips Increases the continuity of the production process Smaller size
Displays in TRMS
Signalling LED 2 signalling LEDs: - ON / Fault trip - Pre-alarm / Reclosure status
- Instant leakage current - Leakage current trip
Connection indicator
Test and reset buttons
With the associated breaking element to carry out earth leakage protection
Test and reset buttons
Parameter display
Programmable Setting using rotating parameter menu. 4 buttons
- Sensitivity - Delay - Channel to be set
Communications Option for RS485 Communications. MODBUS Protocol. Only displays programminutesg parameters, leakage values and status of each channel.
Accessories
TT (see page 26)
WG and WGP differential transformers
P2-13
P.2 Earth leakage and overload/short circuit protection systems with self-reclosure
Overload and earth leakage protection / Earth leakage reclosure INSULATED RELAY WITH SETTABLE SENSITIVITY AND DELAY
Switch formed by: Earth leakage relay + circuit breaker Class A insulated. High-frequency filtering
Settable delay
Settable sensitivity
+ Leakage current level indicator via variable flashing
Relay input: WRKRT-25 T : for resetting WRKRT-25 N : for remote control
Number of poles and line current defined by the contactor
Overload and earth leakage protection + earth leakage reclosure
Applications Street lighting
Telephone systems
• Traffic lights • Cable TV
P2-14
P.2
Poles
Useful diameter ∅ mm
In (A)
Delay (s)
Type
Code
Up to 63 A
2, 3+N
25
0,03...3
0,02...1
WRKRT-25 T
P23111
Up to 63 A
2, 3+N
25
0,03...3
0,02...1
WRKRT-25 N
P23121
Earth leakage and overload/short circuit protection systems with self-reclosure
Earth leakage relay with built in transformer
With sensitivity adjustment on 0.03 A, delay cancelled
Complete set formed by: Earth leakage relay + MCB circuit breaker (suitable for the line)
Protection
Reclosure
WRKRT-25 T
WRKRT-25 N
WRKRT-25 T
Earth leakage and overload protection Class
A Superinsulated
Measuring
TRMS
Sensitivity
Selectable 30 mA ... 3 A
Delay
Selectable 20 ms ... 1 s Built in ∅ 25 mm
Test y Reset
Via built in button
Associated breaking element
MCB.T circuit breaker
Number of poles , In, thermal curve, cut off power
Number of reclosures Time between reclosures
Differential transformer
WRKRT-25 N
Earth leakage reclosure 30
6
20 s, 40 s, los 28 remainder every 5 minutes.
Return to zero time for partial meter
15 minutes
Signalling in the relay
MCB.P circuit breaker
LED
Defined by circuit breaker used Remote-control (inputs)
- Presence of voltage indicator - Sealed reclosure - Indicates the presence of leakage current without reaching the trip point External reset using button
Inputs ON (earth leakage only) and relay OFF
Features WRKRT-25 T / WRKRT-25 N Electrical features Auxiliary power supply Breaking element control contacts
WRKRT-25 T / WRKRT-25 N Mechanical features
230 V a.c. (±20 %) 50...60 Hz Maximum current 3 A a.c.
Operating temperature
Mounting Dimensions Weight
-10 ºC / +50 ºC Protection grade Standards
DIN rail 4 modules 235 g Terminals: IP20, Built in relay: IP41 IEC 61008-1, IEC 755, IEC 255-5, IEC 947-2
Accessories
Circuit breaker MCB (page 23)
P2-15
P.2 Earth leakage and overload/short circuit protection systems with self-reclosure
OVERLOAD AND EARTH LEAKAGE PROTECTION AND RECLOSURE INSULATED RELAY WITH SETTABLE SENSITIVITY AND DELAY
Switch formed by: Earth leakage + overload relay Class A insulated. High-frequency filtering
Settable delay
+ Leakage current level indicator via variable flashing
Settable sensitivity
Number of poles and line current defined by the contactor
Overload and earth leakage protection + Overload and earth leakage reclosure
APPLICATIONS Street lighting
P2-16
Office blocks
P.2
In
Poles
Sensitivity
Type
Code
Up to 63 A
2,4
30 mA
WRU-25 RA-MT
P24241
Type
Number of reclosures
Time between reclosures
WRU-25 RA-MT
6
1 minutes
Earth leakage and overload/short circuit protection systems with self-reclosure
Earth leakage relay with built in transformer
Complete set formed by: Earth leakage relay + MT overload device
Protection
Reclosure
WRU-25 RA-MT
WRU-25 RA-MT
Earth leakage protection Class
A superinsulated
Measuring
TRMS
Sensitivity I∆n
Selectable 30 mA...3 A
Delay
Selectable 20 ms ... 1 s
Differential transformer
Built in ∅ 25 mm
Test y Reset
Via built in button
Associated breaking element
Overload device Serie MT
Rated In thermal curve, cut off power and no. of poles
Defined by overload device used
Breaking element control
Earth leakage and overload reclosure Number of reclosures
6
Time between reclosures
8, 16, 30, 59, 115, 224 s
Return to zero time for partial meter
15 minutes In the overload device. Using disconnection lever.
Safety sealing Signalling in the relay
- Presence of voltage indicator - And/or earth fault indicator
LED Remote signalling (outputs)
Leakage control signal (proportional alternating voltage)
1 switched relay
Features WRU-RA-MT Electrical features Auxiliary power supply Breaking element control contacts Output contacts Operating temperature
230 V a.c. (±15 %) 50...60 Hz 250 V a.c. / 8 A a.c. Maximum current 3 A -10 ºC / +50 ºC
Assembly features Mounting
DIN rail
Dimensions
4 modules
Weight Protection grade Standards
234 g Terminals: IP20, Built in relay: IP41 IEC 61008-1, IEC 755, IEC 255-5
Accessories
MT overload decive (page. 24)
P2-17
P.2 Earth leakage and overload/short circuit protection systems with self-reclosure
Earth leakage relay with external transformer
Class
In (A)
Poles
Toroidal
Delay (s)
Type
Code
A
According to contactor
2,3,4
Serie WG
0,02...1
RGU-10 RA
P24612
Type
Number of reclosures
Time between reclosures
RGU-10 RA
Programmable
Programmable
Complete set formed by: Earth leakage relay + WG toroidal + MT / MT-FDE overload device
Protection
Reclosure Earth leakage and overload reclosure
Earth leakage and overload protection Class
A superinsulated
Measuring
Time between reclosures
TRMS
Return to zero time for partial meter
Programmable 30 mA...30 A
Sensitivity I∆n
Programmable 20 ms ... 1 s Inverse curve: Instant or selective
Delay Differential transformer
Via built in button
Associated breaking element
Defined by overload device used 1 relay simple
Programmable: 1... 900 s 15 / 30 minutes
- Presence of voltage - A channel has tripped- Reclosure enabled - Sealed status - RS-485 Communications
LED
Overload device Serie MT, MT-FDE
Breaking element control
Programmable: 0... 10
Signalling in the relay
External, Serie WG
Test y Reset
In and number of poles
No. of reclosures
Display
LCD
Remote signalling (outputs) Remote-control (inputs)
Prealarm relay ON / OFF
Features Electrical features Auxiliary power supply
230 V a.c. (± 20 %) 50...60 Hz
Breaking element control contacts
5 A a.c. current
Operating temperature
-10 ºC / +50 ºC
Mechanical features Mounting Dimensions
DIN rail 3 modules
Weight Protection grade Standards
236 g Terminals: IP20, Built in relay: IP41 IEC 61008-1, IEC 755, IEC 255-5
Accessories
MT overload device (page 24)
P2-18
MT overload device (page 25)
P.2 Earth leakage and overload/short circuit protection systems with self-reclosure
Other earth leakage relays with different functions
Relays with built in transformer Nº Reclosures
Useful diameter ∅ mm
I∆n (A)
Poles
25
0,03
According to MT
25
0,3
According to MT
Delay (s)
Breaking element control
Remote signalling
Type
Code
10
Relay ON/OFF
Sealed through reclosure
WRT-6-25-0,03
P21121
10
Relay ON/OFF
Sealed through reclosure
WRT-6-25-0,3
P21122
overload
earth leakage
0,02
2
0,02
2
Protection
Reclosure WRT-6-25
WRT-6-25
Earth leakage and overload protection Class
Earth leakage and overload reclosure
A Superinsulated
Measuring
No. of reclosures
TRMS
Sensitivity I∆n
Fixed 30 mA or 300 mA (according to type)
Delay
Fixed 20 ms ∅ 25 mm built in relay
Differential transformer Test y Reset Associated breaking element
Time between reclosures
1 minutes
Return to zero time for partial meter
30 minutes
Safety sealing
Via built in button
2 per overload device and 10 per earth leakage
In the overload device. Using disconnection lever.
Overload device Serie MT
Rated In thermal curve, cut off power and no. of poles
Defined by overload device used
Features Electrical features Auxiliary power supply
Assembly features 230 V a.c. (±15 %) 50...60 Hz
Breaking element control contacts
250 V a.c. / 8 A a.c.
Output contacts
250 V a.c. / 8 A a.c.
Operating temperature
Mounting Dimensions Weight
-10 ºC / +50 ºC
Protection grade Standards
DIN rail 6 modules 425 g Terminals: IP20, Built in relay: IP41 IEC 61008-1, IEC 755, IEC 255-5
Accessories
MT Overload device (page 24)
P2-19
P.2 Earth leakage and overload/short circuit protection systems with self-reclosure
Other earth leakage relays with different functions
Relays with external transformers Number of reclosures
Useful diameter ∅ mm
I∆n (A)
Poles
According to WG
0,03 / 0,3
According to MT
Delay (s)
Overload
earth leakage
2
10
0,02
Breaking element control
Remote signalling
Type
Code
Relay ON / OFF
2
RGMT
P21130
Protection
Reclosure
Protection
Earth leakage and overload reclosure
Class
A Superinsulated
Measuring
2 per overload device and 10 per earth leakage
Number of reclosures
TRMS 0,03 / 0,3 A
Sensitivity I∆n Delay
Fixed 20 ms
Differential transformer
Time between reclosures
3 minutes
Return to zero time for partial meter
30 minutes
External, Serie WG
Test y Reset Associated breaking element
In the overload device. Using disconnection lever.
Safety sealing
Via built in button Overload device Serie MT
Rated In thermal curve, cut off power and no. of poles
Defined by overload device used
Features Electrical features Auxiliary power supply
Assembly features 230 V a.c. (±15 %) 50...60 Hz
Breaking element control contacts
250 V a.c. / 8 A a.c.
Output contacts
250 V a.c. / 8 A a.c.
Operating temperature
Mounting
DIN rail
Dimensions
6 modules
Weight -10 ºC / +50 ºC
350 g Front: IP54, casing and terminals: IP20
Protection grade
IEC 61008-1, IEC 755, IEC 255-5, IEC 947-2, IEC 60898
Standards
Complete Kits The equipment is formed by: • RGMT earth leakage relay
2 Poles Type
Type
Code
P21210
WRGMT-C-4-10 A
P21221
WRGMT-C-2-10 A
P21211
WRGMT-C-4-16 A
P21222
WRGMT-C-2-16 A
P21212
WRGMT-C-4-20 A
P21223
WRGMT-C-2-20 A
P21213
WRGMT-C-4-25 A
P21224
WRGMT-C-2-25 A
P21214
WRGMT-C-4-32 A
P21225
WRGMT-C-2-32 A
P21215
WRGMT-C-4-40 A
P21226
WRGMT-C-2-40 A
P21216
WRGMT-C-4-50 A
P21227
WRGMT-C-2-50 A
P21217
WRGMT-C-4-63 A
P21228
WRGMT-C-2-63 A
P21218
WRGMT-C-2-6 A
• MT series of motorised overload device or MT-FDE series motorised overload switch with overload protection function and breaking element • WG series differential transformer
P2-20
4 Poles Code
P.2 Earth leakage and overload/short circuit protection systems with self-reclosure
EARTH LEAKAGE AND OVERVOLTAGE PROTECTION OVERLOAD AND EARTH LEAKAGE RECLOSURE BREKING ELEMENT: MT
The RGST-2 / RGST-4 is equipment which protects against permanent overvoltages. This continuously measures line voltages and if the value in any phase exceeds the previously set limits, either by a maximum or minimum voltage, the RGST set associated with a breaking device (MT series motorised overload device or similar) interrupts the electricity supply. After a certain time, it tries to reconnect again. Also the RGST, with a WG series transformer is an earth leakage protection relay. The RGST, connected to a motorised overload device allows reclosure in the event of an earth leakage and/or overload trip.
Complete set formed by: RGST Relay + Toroidal WG + MT / MT-FDE overload device Nºumber of reclosures
Useful diameter ∅ mm
I∆n (A)
Poles
according to WG
0,3...0,5
2
0,02
0...3
according to WG
0,3...0,5
4
0,02
0...3
Delay (s)
overload
Breaking element control
Remote signalling
Type
Code
0...10
1 switched
1 NA
RGST-2
P21141
0...10
1 switched
1 NA
RGST-4
P21142
earth leakage
Protection
Reclosure
Earth leakage, overload and overvoltage protection Maximum voltage
Programmable 235...270 V a.c.
Minimum voltage
Programmable 180...210 V a.c.
Conection delay
Programmable 100...980 ms (only for overvoltages)
Class
A Superinsulated
Measuring Sensitivity I∆n Delay Differential transformer
External Serie WG
Test y Reset
Via built in button
No. of poles, In, thermal curve, cut off power
Breaking element control
Time between programmable reclosures Return to zero time for partial meter
TRMS Programmable: 30...500 mA Fixed 20 ms
Associated breaking element
Earth leakage and overload reclosure No. of programmable reclosures
MT series motorised overload device + F6 coil Defined by overload device used
Safety sealing
0...3 per overload device 0...10 per earth leakage 1...60 min. per overload device; 3...250 secs. per earth leakage and overvoltage Programmable 30...60 minutes In the overload device. Using disconnection lever.
Signalling in the relay LED
Display Remote signalling (outputs) Remote-control (inputs)
– Protection and reclosure status indication – Selected parameter indication Numerical. 3 digits. Total number of reclosures and parameter setting NA free of power reclosure seal output Remote ON / OFF input
Using relay (3 relays) ON / OFF and F6 coil. The overload device disconnection is guaranteed in the event of an auxiliary power supply failure
Features Electrical features
Accessories
Auxiliary power supply
230 V a.c. (±15 %) 50...60 Hz
Operating temperature
-10 ºC / +50 ºC
Assembly features Mounting Dimensions Weight WG Transformer (page 10)
MT Overload device (page 24)
Protection grade Standards
DIN rail 8 modules 565 g Front: IP54, Casing: IP20, Terminals: IP20 IEC 61008-1, IEC 755, IEC 255-5, IEC 947-2, IEC 60898
P2-21
P.2 Earth leakage and overload/short circuit protection systems with self-reclosure
OVERLOAD RECLOSURE BREAKING ELEMENT: MT RRM-P, RRM-C The RRM is a relay for overload protection reclosure. It allows the control, remote signalling and remote-control of the associated motorised overload switch (MT and MT-FDE series). The functions of the RRM relay are: • Motorised overload device control: - Self-reclosure - Remote connection/disconnection (not reconnectable) • Signalling: - On site via LED - Remote signalling using relay blocking reclosure in RRM-P - RS485 communications in RRM-C • Automatic switch remote-control
Type
Comunication
Code
RRM-P
Not available
P25130
RRM-C
RS-485
P25131
Complete set formed by: RRM Relay + MT / MT-FDE overload device
Protection
Reclosure
RRM-P Protection
RRM-C Overload
RRM-P Reclosure
Associated breaking element
Overload device Serie MT
Number of poles, In, thermal curve, cut off power
Defined by overload device used
Breaking element control
Control motor contact
RRM-C Overload
Number of programmable reclosures Time between programmable reclosures
Selectable: 0,1,2,4,6,8 times 0.5, 1, 2, 3, 4, 5 minutes
Return to zero time for programmable partial meter Safety sealing
30 minutes In the overload device. Using disconnection lever.
Signalling in the relay – Presence of voltage indicador and no overload trip – Indication of trip through external order – Sealed by ending of reclosures – Reclosure in process
LED
Remote signalling (outputs) Remote-control (inputs)
Relay seal
RS-485 communications
ON / OFF free of power input in breaking element (External OFF not reconnectable)
Features Electrical features
Assembly features
Auxiliary power supply
230 V a.c. (±20 %) 50...60 Hz
Mounting
Breaking element control contacts
250 V a.c., 1 A
Dimensions
Operating temperature
-10 ºC + 50 ºC
Weight Protection grade Standards
DIN rail 1 module 88 g Terminals: IP20, Built in relay: IP41 IEC 947-2
Accessories
MT overload device (page 24)
P2-22
MT-FDE Overload device (page 25)
P.2 The MCB.P or MCB.T our circuit breakers which combine overload functions with contactor functions in the same equipment. The MCB.T version also includes two auxiliary contacts which show the status of the remote control input and the overload input. Both the MCB.P and the MCB.T version include an ordinary contact to indicate a trip from an overload device or from the manual action of the circuit breaker. There are two trip conditions for the circuit breaker: • Tripping from overheating, delayed, (overload protection) • Rapid tripping, electromagnetic (protection against shortcircuiting)
Remote-control operates on the same complex as the overload device, guaranteeing disconnection for any event by remote control after manual or overload device tripping. The remote control operates electro-magnetically, applying a control voltage lasting 20 ms, to the ON terminals (Terminals 1-3) and OFF terminals (Terminals 2-3). It includes an optical displays of the system status (red = ON, green = OFF), regardless of the cause of the trip.
2 Poles
4 Poles
MCB.P
MCB.T
MCB.P
MCB.T
In (A) Type
Code
Type
Code
Type
Code
Type
Code
6
MCB.P C-2p-6A
P20210
MCB.T C-2p-6A
P20310
-
-
-
-
10
MCB.P C-2p-10A
P20211
MCB.T C-2p-10A
P20311
MCB.P C-3p+N-10A
P20221
MCB.T C-3p+N-10A
P20321
16
MCB.P C-2p-16A
P20213
MCB.T C-2p-16A
P20313
MCB.P C-3p+N-16A
P20223
MCB.T C-3p+N-16A
P20323
20
MCB.P C-2p-20A
P20214
MCB.T C-2p-20A
P20314
MCB.P C-3p+N-20A
P20224
MCB.T C-3p+N-20A
P20324
25
MCB.P C-2p-25A
P20215
MCB.T C-2p-25A
P20315
MCB.P C-3p+N-25A
P20225
MCB.T C-3p+N-25A
P20325
32
MCB.P C-2p-32A
P20216
MCB.T C-2p-32A
P20316
MCB.P C-3p+N-32A
P20226
MCB.T C-3p+N-32A
P20326
40
MCB.P C-2p-40A
P20217
MCB.T C-2p-40A
P20317
MCB.P C-3p+N-40A
P20227
MCB.T C-3p+N-40A
P20327
50
MCB.P C-2p-50A
P20218
MCB.T C-2p-50A
P20318
MCB.P C-3p+N-50A
P20228
MCB.T C-3p+N-50A
P20328
63
MCB.P C-2p-63A
P20219
MCB.T C-2p-63A
P20319
MCB.P C-3p+N-63A
P20229
MCB.T C-3p+N-63A
P20329
Features 2 Poles
4 Poles
2 Poles
Overload Calibres In (A) Rated cut off power (IEC 947-2) Characteristic curve Rated operating voltage Operating frequency range
4 Poles
Motor 6-10-16-20-25-32-40-50-63
6...16 A: 20 kA
20...63 A: 15 kA
Rated voltage
230 V a.c.
Activation impulse
< 20 ms
C or D according to type
Deactivation impulse
< 20 ms
230 / 400 V a.c.
Mechanical features
50...60 Hz
Mounting
Operating temperature
-25 ºC / +55 ºC
Dimensions
Storage temperature
-40 ºC / +70 ºC
Mechanical life Weight Protection grade Standards
DIN rail 3 modules
5 modules
20.000 operations 375 g
615 g
IP 20 (DIN 40050) IEC 947-2, IEC 60898
P2-23
Earth leakage and overload/short circuit protection systems with self-reclosure
MCB.P, MCB.T Circuit breaker
P.2 Earth leakage and overload/short circuit protection systems with self-reclosure
MOTORISED OVERLOAD DEVICE, MT Overload device with remote-control. Protection against short-circuit and overloads. Also used as a breaking element. Includes auxiliary contacts for indicating overload status. After a disconnection from short-circuit, overload or manual disconnection the overload switch may be connected again using an electrical order with the sequence “DISCONNECTION (0) - CONNECTION ( I )“
2 Poles
4 Poles
Curve C
I∆n (A)
Curve D
Curve C
Curve D
Type
Code
Type
Code
Type
Code
Type
Code
6
MT-C-E62-6A
P20110
MT-D-E62-6A
P20130
MT-C-E64-6A
P20120
MT-D-E64-6A
P20140
10
MT-C-E62-10A
P20111
MT-D-E62-10A
P20131
MT-C-E64-10A
P20121
MT-D-E64-10A
P20141
16
MT-C-E62-16A
P20112
MT-D-E62-16A
P20132
MT-C-E64-16A
P20122
MT-D-E64-16A
P20142
20
MT-C-E62-20A
P20113
MT-D-E62-20A
P20133
MT-C-E64-20A
P20123
MT-D-E64-20A
P20143
25
MT-C-E62-25A
P20114
MT-D-E62-25A
P20134
MT-C-E64-25A
P20124
MT-D-E64-25A
P20144
32
MT-C-E62-32A
P20115
MT-D-E62-32A
P20135
MT-C-E64-32A
P20125
MT-D-E64-32A
P20145
40
MT-C-E62-40A
P20116
MT-D-E62-40A
P20136
MT-C-E64-40A
P20126
MT-D-E64-40A
P20146
50
MT-C-E62-50A
P20117
MT-D-E62-50A
P20137
MT-C-E64-50A
P20127
MT-D-E64-50A
P20147
63
MT-C-E62-63A
P20118
MT-D-E62-63A
P20138
MT-C-E64-63A
P20128
MT-D-E64-63A
P20148
Features 2 Poles
4 Poles
2 Poles
Overload Calibres In (A) Number de Poles
6-10-16-20-25-32-40-50-63 2
4
Rated cut off power
10 kA
Characteristic curve Rated operating voltage Operating frequency range
Rated voltage
230 V a.c.
Minimum voltage
210 V a.c.
Activation impulse
50 ms
C or D according to type
Desactivation impulse
50 ms
240 / 415 V a.c.
Mechanical features
50...60 Hz
Mounting
DIN rail
Operating temperature
-25 ºC / +55 ºC
Dimensions (mm)
Storage temperature
-55 ºC / +55 ºC
Mechanical life
> 20.000 Operations
Weight (g)
645
Protection grade Standards
P2-24
4 Poles
Motor
5,5 modules:
7,5 modules:
890
IP 40 (DIN 40050) IEC 947-2, IEC 60898
P.2 Earth leakage and overload/short circuit protection systems with self-reclosure
MT-FDE, MT-FEE MOTORISED OVERLOAD DEVICE MT-FDE series overload device with remote control. Protection against short-circuit and overloads. Also used as a breaking element. After a disconnection from short-circuit or overload, the overload device may be reconnected. The reclosure is done in a different way using the position of the lever in operating mode: • “MANU” is done manually in the same switch using the sequence OFF and then ON • “AUTO” is done using an electrical impulse following the sequence OFF and then ON
For currents above 63 A MT-FDE / MT-FEE 3 Poles In (A)
Type
4 Poles
Weight (Kg)
Code
Type
Weight (Kg)
Code
80
MT-FDE-80A
2,9
P20D60
MT-FDE-80A
3,4
P20D70
100
MT-FDE-100A
2,9
P20D61
MT-FDE-100A
3,4
P20D71
125
MT-FDE-125A
2,9
P20D62
MT-FDE-125A
3,4
P20D72
160
MT-FDE-160A
2,9
P20D63
MT-FDE-160A
3,4
P20D73
250
MT-FEE-250A
3,8
P20E64
MT-FEE-250A
4,6
P20E74
Features FDE
FEE
FDE
Magnetotérmico Calibres In (A) Number of Poles Rated cut off power (IEC 947-2) Characteristic curve Rated operating voltage Operating frequency range
FEE
Motor
80-100-125-160
250
Rated voltage
230 V a.c.
3 or 4 according to type
Minimum voltage
210 V a.c.
25 kA
Activation impulse
50 ms
C or D according to type
Desactivation impulse
50 ms
240 / 415 V a.c.
Mechanical features
50...60 Hz
Operating temperature
-25 ºC / +55 ºC
Storage temperature
-55 ºC / +55 ºC
Mounting Dimensions (mm)
Panel (base + pluggable base) 3 Poles: 81 x 130 x 185 4 Poles: 108 x 130 x 185
Weight
According to type
Protection grade
IP 40 (DIN 40050)
Standards
IEC 947-2, IEC 60898
P2-25
P.2 Earth leakage and overload/short circuit protection systems with self-reclosure
Accessories Earth leakage transformers, WG series Weight (g)
Useful diameter (mm)
Type
Code
Weight (g)
Useful diameter (mm)
Type
Code
75
20 ∅
WGS-20
P10131
2.400
70x175
WG-70 x 175
P10116
94
30 ∅
WGS-30
P10132
5.450
115x305
WG-115 x 305
P10117
180
35 ∅
WG-35
P10111
7.400
150x350
WG-150 x 350
P10118
274
70 ∅
WG-70
P10112
13.400
200x500
WG-200 x 500
P10119
544
105 ∅
WG-105
P10113
1.222
140 ∅
WG-140
P10114
2.040
210 ∅
WG-210
P10115
Earth leakage transformers, WGP series (only for cbs-8) Useful diameter (mm)
Type
Code
20 ∅
WGSP-20
P10141
30 ∅
WGSP-30
P10142
35 ∅
WGP-35
P10121
70 ∅
WGP-70
P10122
105 ∅
WGP-105
P10123
140 ∅
WGP-140
P10124
210 ∅
WGP-210
P10125
Useful diameter (mm)
P2-26
Type
Code P19911
Code
70x175
WGP-70x175
P10126
115x305
WGP-115x305
P10127
150x350
WGP-150x350
P10128
Toroidal protection tube
TT-35
Type
Adapters
TT-70
P19912
TT-105
P19913
TT-140
P19914
Description
Equipment
Type
Code
TT-210
P19915
Accessory for mounting on DIN rail
WG-35 ... WG-210
PA-TC/WG
P19921
Panel adapter
RGU-10 RA
Panel adapter
M59991
PA-TC/WG
Panel adapter
REC 2P REC 4P
RGU-RA
GU72-D RA
Earth leakage and overload/short circuit protection systems with self-reclosure
P.2
Dimensions / Connections
P2-27
P.2 Earth leakage and overload/short circuit protection systems with self-reclosure
Dimensions / Conexiones
WRU-35-RA
P2-28
WRU-25-RA
WRU-25-RA-MT
WRU-RM
WRU-RT
WRU-25-2R
WRKRT-25T
MCB.P MT-2 Poles
RRM-P MT-4 Poles
WRT-6-25
Earth leakage and overload/short circuit protection systems with self-reclosure
P.2
Dimensions / Conexiones
RRM-C
P2-29
Earth leakage and overload/short circuit protection systems with self-reclosure
P.2 Dimensions / Conexiones
WRGMT-C2
RGMT
CBS-8
P2-30 WRGMT-C4
RGST-2
Con contactor RGST-4
RGU-10-RA
Earth leakage and overload/short circuit protection systems with self-reclosure
P.2
Dimensions / Conexiones
Con MT
P2-31
cod. C3P021-01
Earth leakage and overload/short circuit protection systems with self-reclosure