INDEX Product Tais Mignon Series

Code

Page

Tais Series

Switched Sockets / Boxes / Interlocked Socket Outlets IP67

3&4

Cam Series

Enclosed Rotary Isolators IP67

4

Alupres Series

Diecast Interlocked Socket Outlets IP67

5&6

Alumax Series

High Current Socket Outlets (200A - 400A) IP65 / IP67

7&8

Tais Mignon-EX Series

Switches / Push buttons Pushbutton Panels IP66

9

Cam-EX Series

Isolator Switches IP66 / IP67

10

Alupres-EX Series I/L Socket Outlets

Female Switched Sockets (with fuses) / Female Switched Sockets / Boxes IP66

11

CEE-EX Series

Plugs IP66

12

Alupres-EX Series

Junction Boxes IP66

13

Rino-EX Series

Fluorescent Fittings IP66

14

Rino-EX Series

Bulkhead Fittings IP65

15

Alarm-EX Series

Sirens IP66 & Bells IP55

16

Uni-EX Series

Adaptors IP67

17

Rino Series

Marine Fluorescent Fittings IP66

17

Tunnel 54 Series LED Lighting

LED Tunnel Lighting Fixtures IP66

18

Rino Series

Lighting Fixtures IP66

19

Nave Series Marine Products

Bells / Switches / Sirens / Bulkhead Fittings IP66

20

Technical Information

IP Degree of Protection of Enclosures

21

Technical Information

Resistance to Chemical Agents and Atmospheric Conditions

22

Small Rocker Switches / Push Buttons / Start-Stop / Junction Boxes IP67 / IP65

2

In 1904 Palazzoli began its activity in Brescia when electrical energy was first used in the industry. The company is specialized in manufacturing electrical appliances with safety features that are protected and watertight, for industrial, marine, civil, agricultural and OEM applications. The offer of PALAZZOLI extends into a wide range of finished products, to which special customized solutions are specifically developed in accordance to the needs of end-users. The product conforms to technical and safety standards and is manufactured with very high quality materials, in metal and self-extinguishing isolated thermosetting (GRP) and thermoplastic. Palazzoli undertakes the commitment towards all end-users to offer reliable, safe and lasting quality products at the best service. This task, as in the last century of activity, continues to honour the trust and respect that customers have posted in its trademark. All products of PALAZZOLI are developed using the latest manufacturing and material technologies for sustainable processes, products and recycling.

1

TEC

TAIS MIGNON SERIES - SMALL DEVICES

The small devices of TAIS-MIGNON are a complete range of control devices, sockets and optical signals integrated inside modular thermosetting (GRP) enclosures with very compact dimensions. See page 22 for table of chemical resistance.

Rocker Switches - in thermosetting (GRP), technopolymer cable gland - IP67 202271 202276 Code Poles

1P (1 Lever)

Entry Type

1CO (1 Lever) 1 x M20 (Top)

Box Dimensions (mm)

202282

2P (2 Lever)

62 x 80 x 48

Rated Current/Voltage

16A/250VAC, 10A/400VAC

Push Buttons - in thermosetting (GRP), technopolymer cable gland - IP67 261435 Code 1NO

Contact Configuration Entry Type

1 x M20 (Top)

261445 1NC

62 x 80 x 51

Box Dimensions (mm)

10A/400VAC

Rated Current/Voltage

Start-Stop Push-Button Station - In thermosetting (GRP), technopolymer cable gland - IP67 Code

261432

Entry Type

1 x M20 (Top)

Rated Current/Voltage

10A/400VAC

62 x 80 x 51

Box Dimensions (mm)

Junction Boxes - In thermosetting (GRP), technopolymer cable gland - IP65 Code 101021 101031 101041 101061 101151 101161

Entry Type 3 x M20 4 x M20

5 - 13

Made of Thermosetting (GRP) to resist high temperatures and chemicals.

Top / Bottom / Side

Top / Bottom / Left / Right

Top / Bottom / 2 x Left / 2 x Right

6 x M25

Top / Bottom / 2 x Left / 2 x Right

6 x M20

Conformity to standards Material Colour Resistance to abnormal heat and fire ("Glow Wire" as per IEC/EN 60695-2-10) Self-extinguishing grade (as per UL94) Resistance to Impacts (IK rating as per IEC/EN 62262) Insulation Class Storage Temperature Operating Temperature

Cable Diameter (mm)

Top / Bottom

6 x M20

Features

Cable Entry Specifications Entry Size M20

Entry Position

2 x M20

Top / Bottom / 2 x Left / 2 x Right

External Size mm 62 x 80 x 38 62 x 80 x 38 62 x 80 x 38 62 x 80 x 38

77 x 102 x 48 77 x 102 x 48

IEC/EN 60669-1; CEI 23-50 ; IEC/EN 60309-1; IEC/EN 60309-2 Thermosetting (GRP) RAL5015 (Cover), RAL7042 (base) 960°C V0 IK04 II -50°C - +80°C -25°C - +70°C

M25

8 - 19

IP67 - Resistant to liquids and humidity

Easily assembled and are able to create small combinations

TEC

Compact dimensions and can be either flush mounted or wall mounted. (Flush mounted units only available ex-indent)

2

TAIS SERIES - INTERLOCKED SOCKET OUTLETS

TAIS series low voltage switched sockets with mechanical interlock are a range of products in thermosetting (GRP) for heavy duty use. The system contains versions from 16A up to 125A, with or without fuses, with MCB integrated or with an EN 50022 rail that can be fitted with modular devices. All the sockets have an IP67 or IP66/IP67 protection rating and can be combined in compositions thanks to the boxes with blind cover or transparent window. The interlock system is made of steel and the isolator switch is certified for AC3-AC23A category at the rated current. See page 22 for table of chemical resistance.

Switched Sockets Mod. 125 - in thermosetting (GRP) with mechanical interlock IP67 Code

Amps

Poles

467126 467136 467146 470226 470236 470246 470233 470336 470346

16A

2P +

16A 16A 32A 32A 32A 32A 63A 63A

Rated Voltage 230V

3P +

3P + N + 2P + 3P +

3P + N + 3P + 3P +

Socket AC23A @ Terminal Capacity Colour h. ref. 400V Red

400V

Red

400V

Blue

230V

Red

400V 400V

Container 380/500V

3P + N +

Blue

400V

Red Red Red Red

400V

7.5kW

6

7.5kW

1-10mm2

15kW

1-10mm2

15kW

1-10mm2

34kW

6-16mm2

6 6 6 6 3 6 6

7.5kW

1-10mm

2

15kW

1-10mm

2

15kW

1-10mm

2

34kW

6-16mm

2

Max no. of installable sockets No. of DIN Mod Mod. 125 Blind Cover 1 532200 2 532202 3 532204 Transparent Window 1 5 532300 2 12 532302 3 19 532304

Blind Cover

Transparent Window

Code

Size (mm) LxWxH

538425 538432

125x185x125

M25 M32

380x185x125

Code 538800 538802 538804

125x185x150 250x185x150 380x185x150

350 x 125 x 185 350 x 125 x 185 350 x 125 x 185 385 x 125 x 203 385 x 125 x 203

M32 M32 M32 M32 M32 M32

25.5 32.5

Max Ø for cable passage 16mm 20mm

1

125 x 630

3

380 x 630

250 x 630

2

Conformity to standards

IEC/EN 60309-1, IEC/EN 60309-2,

Body Material

Thermosetting (GRP)

IEC/EN 60529)

IEC/EN 60309-4, IEC/EN 60947-3 IP67

Colour

RAL5015 (Cover), RAL7042 (base)

fire ("Glow Wire" as per

960°C

Self-extinguishing grade

V0

Resistance to Impacts (IK rating

IK10

Rated Current

16A - 32A - 63A - 125A

Rated Frequency

50-60Hz

Resistance to abnormal heat and IEC/EN 60695-2-10) (as per UL94)

as per IEC/EN 62262) Rated Voltage

Rated Insulation Voltage Insulation Class

Storage Temperature

Operating Temperature

TEC

350 x 125 x 185

M25

Max no. of installable Size (mm) sockets Mod. 125 WxH

Protection Rating (IP as per

3

M25

350 x 125 x 160

M25

Mounting Plates - In thermosetting (GRP) with guided system for composition of socket boards

250x185x125

Instructions

350 x 125 x 160

350 x 125 x 160

Hole Mounting Type hole mm

Features

Certificates

Entry

Fitting - for rapid coupling in technopolymer, for composition of socket boards IP66/IP67

Boxes - In thermosetting (GRP) for composition of socket boards IP66/IP67

Code

1-10mm

6

2

Size (mm) HxWxD

24-690VAC 690VAC II

-50°C - +80°C -25°C - +50°C

TAIS SERIES - INTERLOCKED SOCKET OUTLETS

Possible Configurations of Tais Interlocked Socket Outlets

250

380

185

185

125

532200

532202

532204

5M

12M

19M

532300

532302

532304

532200

532202

532204

532302

532304

630 500

532300

M125

M125

538800

M125

M125

538802

M125

M125

538804

CAM SERIES - ENCLOSED ROTARY ISOLATORS IP67

25-63A

100-600A

Isolator Switches - In Thermosetting (GRP) - IP67 No. of Rated AC23A @ Terminal Size (mm) Code Entry Type Poles Current 400V Capacity W x H x D 1-10mm2 92 x 125 x 122 12kW 2 x M25 25A 2 292201 12kW 2 x M25 25A 1-10mm2 92 x 125 x 122 3 292202 12kW 2 x M25 25A 1-10mm2 92 x 125 x 122 4 292203 19kW 2 x M32 40A 4-10mm2 125 x 185 x 165 3 292302 19kW 2 x M32 40A 4-10mm2 125 x 185 x 165 4 292303 34kW 2 x M32 63A 6-16mm2 125 x 185 x 165 3 292412 34kW 2 x M32 63A 6-16mm2 125 x 185 x 165 4 292413 10-25mm2 185 x 250 x 261 45kW 2xa 100A 4 292503* 52kW 2xb 200A 16-70mm2 250 x 250 x 261 4 292623* 2 x c 400A 370 x 500 x 261 4 292703* 2xc 600A 370 x 500 x 261 4 292733* 25-63A Supplied without glands. *100-600A supplied without blind flanges. Blind flanges to be ordered separately.

Blind Flanges - To be ordered separately Code 538130 538230 538330

Type a b c

Features

Conformity to standards Material Protection Rating (IP as per IEC/EN 60529) Colour Resistance to abnormal heat and fire ("Glow Wire" as per IEC/EN 60695-2-10) Self-extinguishing grade (as per UL94) Resistance to Impacts (IK rating as per IEC/EN 62262) Rated Voltage Insulation Class Storage Temperature Operating Temperature

TEC

Size (mm) 110 x 60 175 x 60 295 x 60

Flange Height 45 45 45

IEC/EN 60947-3; IEC/EN 60947-5-1 Thermosetting (GRP) IP67 RAL5015 (Cover), RAL7042 (base) 960°C V0 IK10 690VAC II -50°C - +80°C -25°C - +70°C

4

ALUPRES SERIES - DIECAST INTERLOCKED SOCKET OUTLETS ALUPRES series low voltage switched sockets with mechanical interlock are a range of products in aluminium alloy for heavy duty use. The system contains versions from 16A up to 250A, with or without fuses, with MCB integrated or with an EN 50022 rail that can be fitted with modular devices. All the sockets have an IP67 protection rating and can be combined in compositions thanks to the dedicated boxes with blind cover or transparent window. The casing is treated with eco-friendly anticorrosion passivation using fluoro-zirconium and coated with hot polymerized scratch-resistant non-toxic polyester paint. The interlock system is made of steel and the isolator switch is certified with the AC3-AC23A category at rated current. See page 22 for table of chemical resistance.

Switched Sockets Mod. 125 - In Aluminium Alloy with mechanical interlock IP67 Socket Rated Amps Poles h. ref. Code Colour Voltage 2P + Blue 16A 230V 6 SF29641 3P + Red 16A 400V 6 SF29642 3P + N + Red 16A 400V 6 SF29643 3P + Black 16A 500V 7 SF29649 2P + Blue 32A 230V 6 SF29644 3P + Red 32A 400V 6 SF29645 3P + N + Red 32A 400V 6 SF29646 3P + Black 32A 500V 7 SF29650 3P + Red 63A 400V 6 SF29647 3P + N + Red 63A 400V 6 SF29648 3P + Black 63A 500V 7 SF29651 Switched Sockets Mod. 185 - In Aluminium Alloy with mechanical interlock IP67 Red 3P + 125A 400V 6 SF29652 Red 3P + N + 125A 400V 6 SF29653 Black 3P + 125A 500V 7 SF29654 Sockets supplied with bottom blind flange. Top flange to be ordered separately.

AC23A @ 400V

7.5kW

1-10mm2

7.5kW

1-10mm2

15kW

1-10mm2

15kW

1-10mm2

34kW

6-16mm2

7.5kW

1-10mm2

7.5kW

1-10mm2

15kW

1-10mm2

15kW

1-10mm2

34kW

6-16mm2

34kW

6-16mm2

52kW

6-70mm2

52kW

6-70mm2

52kW

Features

Conformity to standards

Entry F1

Body Material Surface Treatment Painting Protection Rating (IP as per IEC/ EN 60529)

Entry F2

Colour Resistance to Impacts (IK rating as per IEC/EN 62262) Rated Current Rated Voltage Rated Frequency Rated Insulation Voltage Insulation Class Storage Temperature Operating Temperature

Entry F1

Certificates

Sockets 16-32-63A

5

TEC

Terminal Capacity

6-70mm2

Flange Type F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F1 F3 F3 F3

IEC/EN 60309-1, IEC/EN 60309-2, IEC/EN 60309-4, IEC/EN 60947-3 Aluminium Alloy Passivation with fluoro-zirconium Hot polymerized non-toxic polyester IP67 (version 16A/32A/63A) IP65 (version 125A) IP55 (version 250A) RAL2011 (Cover), RAL7035 (base) IK10 16A - 32A - 63A - 125A - 250A 24V - 690V 50-60Hz 690V I -30°C - +70°C -25°C - +50°C

Instructions

ALUPRES SERIES - DIECAST INTERLOCKED SOCKET OUTLETS Junction Boxes Code 511214 511237 511312

Socket Type

Flanges - To be ordered separately

Flange Type

Size (mm)

Code

Flange Type

547021 547031 547151 547053 540091 540033 541055 540180 540185 540186 540190 540195 SL461126 SL461137 SL461127

Reduction flange F2 to F1

Mod. 125

F1 x 4

125 x 125 x 63

Mod. 185

F3 x 4

185 x 185 x 95

Mod. 125

F1 x 4 + F2 x 1 252 x 125 x 63

Blind Covers for Junction Boxes Code

Socket Type

SL461133 Mod. 125 SL461134 Mod. 125 SL461131 Mod. 185 Transparent Cover SL461135 Mod. 125 SL461136 Mod. 125 SL461132 Mod. 185 Mounting Plates Code 532876 532836

Socket Type

Mod. 125 Mod. 125

No. of Din Mod

Size (mm)

-

252 x 125 x 50

-

125 x 125 x 10

-

185 x 185 x 50

4

125 x 125 x 50

9

252 x 125 x 50

7.5

185 x 185 x 50

No. of Sockets

Size (mm)

2

558 x 250

1

125

F1

F1 F1

F1

Reduction flange F5 to F1 Reduction flange F5 to F3 Blind closing flange F1

Blind closing flange F3 Flat flange F1 / M25

Raised flange F1 / M32 Raised flange F2 / M32 Raised flange F2 / M40 Raised flange F3 / M40 Raised flange F5 / M50

2 Entry Threaded Flange F1 / 2x M25

2 Entry Threaded Flange F3 / 2x M32 2 Entry Threaded Flange F3 / 2x M40

558 x 125

Possible Configurations of Alupres Sockets & Accessories 125 250 M125

Reduction flange F3 to F1

Switched Sockets - Module 125, 16A/32A and 63A

M125+M125

F2

F1

F1

F1

F1

Box

Box

511237

125

511214

Blind Cover

Blind Cover

SL461134

125

SL461133

Transparent Window

SL461135

Transparent Window

SL461136

421

558

Switched Sockets - Module 185, 125A

M125

Mounting Plate

532876

M125

M125

Mounting Plate

532836

TEC

6

ALUMAX SERIES - HIGH CURRENT SOCKET OUTLETS 200-400A

ALUMAX series low voltage switched sockets with electrical interlock are a range of products in 15/10 steel sheet, finished with hot polymerized scratchresistant non-toxic polyester painting, equipped with an aluminium alloy socket for heavy duty uses, from 250A up to 400A, with IP65 protection rating. Each connection is equipped with a double pilot contact. The sockets (electrically interlocked) are equipped with earth leakage MCCB with 36kA breaking capacity. The operator can be padlocked both at 0 and 1 position. See page 22 for table of chemical resistance.

Switched Sockets IP65 - For use from 400V to 1000V In steel with electrically interlocked circuit breaker.

Code 480530 480550 480531 480551 480650 480651 480750 480751 Connections Features

Material Surface Treatment Protection Rating Cable Entrance Diameter Type of Connection

Rated Voltage Rated Frequency

General Features

Conformity to Standards Impact Resistance Working Temperature Insulation Class Pilot Contacts Pilot Contacts Section Rated Current

Rated Voltage

Amps

400V

250A

400V 500V

3P +

400A

400V

400A

500V

2x6

250A

320A

500V

3P + N +

3P +

320A

400V

N. Pilot Contacts (mm2)

250A

250A

500V

Poles

2 x 10 2 x 10

3P + N +

2x6

3P + N +

2x6

3P + N +

2x6

3P + N +

2x6

3P + N +

2x6

Interlocked Sockets Features

Aluminium alloy Passivation with Fluoro-Zirconium IP67 42mm (250A) 62mm (320A - 400A) Screw type: for 50mm² - 70mm² cables Crimping type: for 120mm² cables (320A) for 150mm² cables (400A) Up to 1000V 50-60Hz

Material Painting Colour

Protection Rating Cable Entrance MCCB Icu Rated Insulation Voltage Rated Frequency

Painted Steel Hot Polymerized non-toxic Polyester Grey RAL 7035 (enclosure) Blue RAL 5012 (door) IP65 Customizable Flange 36kA 690V 50-60Hz

Certificates

Instructions

IEC/EN 60309-1 IEC/EN 60947-3 IK10 -30°C - + 60°C I 2 6mm² - 10mm² 250A - 320A - 400A The particular shape of the plug and receptacle allow easy coupling which is also facilitated by the multi-lamellar Easy Contact technology.

Standard 250Amp versions are equipped

with screw type terminals that grant maximum versatility.

7

TEC

ALUMAX SERIES - HIGH CURRENT SOCKET OUTLETS 200-400A Plugs - In aluminium alloy with anticorrosion treatment IP67

Code 750530 750550 750650 750750

Rated Voltage

Amps

Poles

1000V

250A

3P +

1000V

320A

3P + N +

1000V 1000V

250A 400A

3P + N + 3P + N +

Connectors - In aluminium alloy with anticorrosion treatment IP67

N. Pilot Contacts (mm2) 2 x 10 2x6 2x6

Code 760530 760550

751530 751550

Rated Voltage

Amps

Poles

250A

3P +

1000V

250A

1000V

Dimensions - Sockets

3P + N +

Amps

1000V

250A

1000V

250A

N. Pilot Contacts (mm2)

Poles 3P +

2 x 10

3P + N +

2x6

2x6

Panel Socket - In aluminium alloy with anticorrosion treatment IP67

Panel Inlet - In aluminium alloy with anticorrosion treatment IP67

Code

Rated Voltage

N. Pilot Contacts (mm2) 2 x 10 2x6

Code 761530 761550

Rated Voltage 1000V 1000V

Amps 250A 250A

N. Pilot Contacts (mm2)

Poles 3P +

2 x 10

3P + N +

2x6

Rated Current (A)

250A

320/ 400A

A (mm)

180

180

C (mm)

650

660

B (mm)

D (mm) E (mm)

Plugs

Connectors

Rated Current (A)

A (mm)

B (mm)

190 400 450

Panel Inlet

500 550

250A

320/ 400A

120

155

287.5

Ø(mm) Max 42 Entry Cable

270

378 62

Panel Socket

TEC

8

TAIS MIGNON-EX SERIES - SMALL DEVICES

Small control devices in antistatic thermosetting (GRP) suitable for applications in areas at risk of explosive atmospheres as defined in ATEX Directive 94/9/ EC and 2014/34/UE. The cover is attached to the back box by means of stainless steel screws, the sealing is guaranteed by a gasket in non-ageing elastomer. See page 22 for table of chemical resistance.

Switches - in thermosetting (GRP), for wall mounting, c/w cable glands/blanking plugs IP66 Code 202271EX 202282EX 202276EX Electrical Scheme

1P (1 Lever)

Entry Type

1 x M20 (Top)

Rated Current/Voltage

2P (1 Lever)

2 x M20 (Top, Bottom)

16A/250VAC, 10A/400VAC

1CO (1 Lever) 1 x M20 (Top)

Pushbuttons - in thermosetting (GRP), for wall mounting, c/w cable glands/blanking plugs IP66

202271EX

202276EX

Code

261435EX

261435EX

Contact Configuration

202282EX

1NO

Entry Type

261445EX

1 x M20 (Top)

1NC

10A/400VAC

Rated Voltage

Pushbutton Panel - in thermosetting (GRP), for wall mounting, c/w cable glands/blanking plugs IP66 Code

261432EX

261432EX

Function

Start/Stop

Entry Type

261433EX

261433EX

1 x M20 (Top)

On/Off

10A/400VAC

Rated Voltage

Features

ATEX Directive 2014/34/EU EN 60079-0:2012 + A11:2013 EN 60079-15:2010 EN 60079-31:2014 Directive 2014/35/EU EN 60669-1:1999 + A1:2002 + A2:2008 + lS1:2009 EN 60947-5-1:2004 + A1:2009 (Push-buttons) II 3G 3D Ex nR IIC T6 Gc Ex tc IIIC T 70 °C Dc Antistatic thermosetting (GRP) <109 Ω (prevention of electrostatic charge deposit) RAL 9005 (black) IP66 960°C

Conformity to standards

Atex Execution Material Surface Resistivity Colour Protection Rating (IP as per IEC/EN 60529) Resistance to abnormal heat and fire (“Glow Wire”as per IEC/EN 60695-2-10) Self-extinguishing grade (as per UL94) Insulation Class Entry Cable Diameter Operating Temperature

V0 II 10-14mm -20°C - +40°C

Zone Suitability Description Zone Usable

9

0

Gas 1

2

X

20

Dust 21 X

22 X

FLP

Certificates

Instructions

CAM-EX SERIES - ENCLOSED ROTARY SWITCHES

Watertight control devices in aluminium alloy suitable for applications in areas at risk of explosive atmospheres as defined in ATEX Directive 94/9/EC and 2014/34/UE. Back box and cover are treated with ecological anticorrosion passivation with fluoro-zirconium and finished with hot polymerized scratchresistant non-toxic polyester painting. The cover is attached to the back box by means of stainless steel screws, the sealing is guaranteed by a gasket in non-ageing elastomer. Pre-configured for internal and external earth connection.The isolator switch is an AC3-AC23A class switch at rated current with the capacity of withstanding a short circuit ≥ 10kA. See page 22 for table of chemical resistance. Isolator Switches - In aluminium alloy for wall mounting, c/w cable glands IP66/67

Code 272241EX

No. of Poles

272242EX 272243EX 272244EX 272302EX Isolator Switch

272303EX 272304EX 282402EX

AC23A @400V

Entry Type

12kW

2 x M25 (Top/Bottom)

25A

12kW

4

25A

6

2

25A

3

Terminal Size (mm) Capacity W x H x D 1 - 10m2

92 x 138 x 102

2 x M25 (Top/Bottom)

1 - 10m

92 x 138 x 102

12kW

2 x M25 (Top/Bottom)

1 - 10m

92 x 138 x 102

25A

12kW

2 x M25 / 2 x M25 (Top/Bottom)

1 - 10m

125 x 185 x 148

3

40A

19kW

2 x M32 (Top/Bottom)

4 - 10m

125 x 232 x 137

4

40A

19kW

2 x M32 (Top/Bottom)

4 - 10m

125 x 232 x 137

6

40A

19kW

2 x M32 / 2 x M32 (Top/Bottom)

4 - 10m

125 x 292 x 148

34kW

2 x M32 (Top/Bottom)

6 - 16m

125 x 292 x 148

34kW

2 x M32 (Top/Bottom)

6 - 16m

125 x 292 x 148

34kW

2 x M32 / 2 x M32 (Top/Bottom)

2

6 - 16m

125 x 292 x 168

3

282403EX

Rated Current

63A - Zone 21-22

4

50A - Zone 2

2 2 2 2 2 2 2 2

282404EX

6

272246EX

3

25A

12kW

1 x M25 / 2 x M25 (Top/Bottom)

1 - 10m2

125 x 232 x 148

4

25A

12kW

1 x M25 / 2 x M25 (Top/Bottom)

1 - 10m

125 x 232 x 148

3

50A

34kW

1 x M32 / 2 x M32 (Top/Bottom)

6 - 16m

125 x 292 x 168

4

50A

34kW

1 x M32 / 2 x M32 (Top/Bottom)

6 - 16m

185 x 359 x 190

Selector Switches - In aluminium alloy for wall mounting, c/w cable glands IP66/67

272247EX Selector Switch

282406EX

282407EX*

2 2 2

* Protection Rating: IP65

Features

Conformity to standards

ATEX Directive 2014/34/EU

EN 60079-0:2012 + A11:2013 EN 60079-15:2010 EN 60079-31:2014

Directive 2014/35/EU

EN 60947-3:2009 + A1:2012 EN60947-1:2007 + A1:2011

Atex Execution

II 3G 2D

Ex nR IIC T6 Gc

Ex tb IIIC T 70 °C Db

Material

Aluminium Alloy

Surface Treatment

Passivation with fluoro-zirconium

Painting

Hot polymerized non-toxic polyester

Colour

RAL 9005 (black) IP66/67

Protection Rating (IP as per IEC/EN 60529) Rated Current

16A - 25A - 40A - 63A

Rated Voltage

500V

Rated Frequency

50-60Hz

Conditional Short-Circuit current - Isolator Switch

≥ 10kA

Service Life

>1 000 000 operations (Mechanical)

Insulation Class

I

Operating Temperature

Zone Suitability Description Zone Usable

-20°C - +40°C

0

Gas 1

2 X

20

Dust 21 X

22 X

FLP

Certificates

Instructions

10

ALUPRES-EX SERIES - INTERLOCKED SOCKET OUTLETS

Wall-mounted interlocked socket-outlets in aluminium alloy suitable for applications in areas at risk of explosive atmospheres as defined in ATEX Directive 94/9/EC and 2014/34/UE. Back box and cover are treated with ecological anti-corrosion passivation with fluoro-zirconium and finished with hot polymerized scratch-resistant non-toxic polyester painting. The interlock system is made of metal, and the inside isolator switch is an AC23A-AC3 class switch at rated current. The cover is attached to the back box by means of stainless steel screws, the sealing is guaranteed by a gasket in non-ageing elastomer. Supplied with flange with insulated cable gland. See page 22 for table of chemical resistance.

Female Switched Sockets c/w Fuses - in aluminium alloy with mechanical interlock, for wall mounting IP66 Rated Socket AC26A Terminal Amps Poles Fuses Code Voltage Colour h. ref. @ 500V Capacity Entry Black 7 16A 500V 1-10m2 M25 (Top) 10.3 x 38 3P + 8.5kW 465137EX 2 Black 32A 7 500V M32 (Top) 14 x 51 3P + 17kW 1-10m 472546EX 2 Black 63A 7 500V M32 (Top) E33 DIII 3P + 44kW 6-16m 472547EX Female Switched Sockets - in aluminium alloy with mechanical interlock, for wall mounting IP66 AC26A Terminal Rated Socket Amps Poles Code Voltage Colour h. ref. @ 500V Capacity Entry 16A 6 230V M25 (Top) 2P + Blue 7.5kW 1-10m2 466126EX 2 16A 6 400V M25 (Top) 3P + Red 7.5kW 1-10m 466136EX 2 16A 6 400V M25 (Top) 3P + N + Red 7.5kW 1-10m 466146EX 2 32A 6 230V M32 (Top) 2P + Blue 15kW 1-10m 460226EX 2 32A 6 400V M32 (Top) 3P + Red 15kW 1-10m 460236EX 2 32A 6 400V M32 (Top) 3P + N + Red 15kW 1-10m 460246EX 2 63A 6 400V M32 (Top) 3P + Red 34kW 6-16m 460336EX 2 63A 6 400V M32 (Top) 3P + N + Red 34kW 6-16m 460346EX Mounting Plates - in painted steel Boxes - in aluminium alloy with blind cover for composition of socket for composition of socket boards boards IP66 Max. Power Dissipation External Installable External allowed (W) Window Type Code Code Size mm Devices Size mm Gas Dust 2 x F1 (Top / Bottom) 125 x 125 13 20 125 x 558 532876 1 511914EX F2 (Top), 2 x F1 (Bottom) 252 x 125 25 40 250 x 558 532836 2 551919EX

Material Surface Treatment Painting Colour Protection Rating (IP as per IEC/EN 60529) Rated Current Rated Voltage Rated Frequency Conditional Short-Circuit current - Isolator Switch Rated Insulation Voltage Insulation Class Operating Temperature

ZONE Usable

11

125

250

16A - 32A - 63A 50V - 500V 50-60Hz ≥ 10kA 690V I -20°C - +40°C

532876 Certificates

Zone Suitability

Description

Possible Configurations of Alupres Sockets & Accessories

558

Atex Execution

ATEX Directive 2014/34/EU EN 60079-0:2012 + A11:2013 EN 60079-15:2010 EN 60079-31:2014 Directive 2014/35/EU EN 60309-1:1999 + A1:2007+ A2:2012 EN 60309-2:1999 + A1:2007 + A2:2012 EN 60309-4:2007 + A1:2012 II 3G 2D (Sockets) Ex nR IIC T6 Gc; Ex tb IIIC T 80/100/115 °C Db (boxes) Ex nR IIC Gc; Ex tb IIIC Db Aluminium Alloy Passivation with fluoro-zirconium Hot polymerized non-toxic polyester RAL 9005 (black) IP65 (40- 63A) / IP66

558

Features

Conformity to standards

0

Gas 1

2

X

20

Dust 21 X

22 X

FLP

532836 Instructions

CEE-EX SERIES - PLUGS IP66

Low voltage watertight straight plugs, IEC EN 60309-1 and IEC EN 60309-2 standard, suitable for applications in areas at risk of explosive atmospheres as defined in ATEX Directive 2014/34/UE. The body of the plug is made of very thick anti-static technopolymer in RAL 9005 black colour. The contact holder

insert is in self-extinguishing technopolymer for versions up to 32A and in thermosetting (GRP) material for the 63A version.The plugs feature IP66 protection rating. Supplied with flange with insulated cable gland. See page 22 for table of chemical resistance.

16A 32A

63A

Male Plugs - with cable gland Amps Poles Code 477303EX

16A

2P +

h. ref.

Rated Voltage Voltage Colour 230V

Blue

Terminal Capacity

477413EX

16A

3P +

6

400V

Red

1-4mm2

477423EX

16A

3P + N +

6

400V

Red

1-4mm2

477513EX

16A

3P +

7

500V

Black

1-4mm2

477306EX

32A

2P +

6

230V

Blue

2.5-10mm2

477416EX

32A

3P +

6

400V

Red

2.5-10mm2

477426EX

32A

3P + N +

6

400V

Red

2.5-10mm2

477516EX

32A

3P +

7

500V

Black

2.5-10mm2

477417EX

63A

3P +

6

400V

Red

4-16mm2

477427EX

63A

3P + N +

6

400V

Red

4-16mm2

477517EX

63A

3P +

7

500V

Black

4-16mm2

Features

Conformity to standards

6

1-4mm2

ATEX Directive 2014/34/EU EN 60079-0:2012 + A11:2013 EN 60079-15:2010 EN 60079-31:2014 Directive 2014/35/EU EN 60309-1:1999 + A1:2007 EN 60309-2:1999 + A1:2007 + A2:2012

Atex Execution

II 3G 2D Ex nA IIC T6 Gc Ex tb IIIC T 65 °C Db

Body Material

Anti-static high thickness technopolymer

Surface Resistivity

<109 Ω (prevention of electrostatic charge deposit)

Protection Rating (IP as per IEC/EN 60529)

IP66

Colour

RAL 9005 (Black)

Resistance to abnormal heat and fire

850°C (handle)

("Glow Wire" as per IEC/EN 60695-2-10)

850°C (16A/32A contact holder) 960°C (63A contact holder)

Self-extinguishing grade (as per UL94)

V2

Rated Current

16A - 32A - 63A

Rated Voltage

50V - 500V

Rated Frequency

50-60Hz

Rated Insulation Voltage

690V

Operating Temperature

-20°C - +40°C

Certificates Zone Suitability Description ZONE Usable

0

Gas 1

2

X

20

Dust 21

Instructions

22 X

FLP

12

ALUPRES-EX SERIES - JUNCTION BOXES

Watertight wall-mounting boxes in aluminium alloy suitable for applications in areas at risk of explosive atmospheres as defined in ATEX Directive 2014/34/UE. Back box and cover are treated with ecological anticorrosion passivation with fluoro-zirconium and finished with hot polymerized scratchresistant nontoxic polyester painting. The cover is attached to the back box by means of stainless steel screws, the sealing is guaranteed by a gasket in nonageing elastomer. Pre-configured for internal and external earth connection. See page 22 for table of chemical resistance.

Junction Boxes - in aluminium alloy with blind walls and back plate IP66 Code 511913EX

Max power dissipation allowed (W)

External Size (mm)

40

185 x 185 x 145

42

252 x 185 x 145

20

511920EX 511921EX

125 x 125 x 113

Junction Boxes - in aluminium alloy with windowed walls and back plate IP66 Code 511911EX

511912EX 511917EX 511922EX 511923EX

Window Type

12

2 x F0 (Top/Bottom)

23

2 x F0 (Top/Bottom)

185 x 92 x 77

40

2 x F1 (Top/Bottom)

252 x 125 x 113

45

4 x F3

220 x 220 x 108

65

2 x F5 (Top/Bottom)

252 x 252 x 197

Flange - in aluminium alloy with metric threading for windowed boxes IP67 Code 541050EX 540180EX 540185EX 540186EX 540190EX 540195EX Features

Conformity to standards

125 x 92 x 77

For Windows

Threading Type M25 x 1.5

18mm

F1

M25 x 1.5

18mm

F1

M32 x 1.5

51mm

F2

M32 x 1.5

51mm

F2

M40 x 1.5

51mm

F3

M40 x 1.5

51mm

F5

M50 x 1.5

51mm

F0

541055EX

Projection

ATEX Directive 2014/34/EU

EN 60079-0:2012 + A11:2013 EN 60079-7:2007

EN 60079-31:2014

ATEX Directive 2014/35/EU EN 62208:2011

Atex Execution

II 2G 2D

Ex e IIC Gb

Ex tb IIIC Db

Body Material

Aluminium alloy

Surface Treatment

Passivation with fluoro-zirconium

Painting

Hot polymerized non-toxic polyester

Colour

RAL 9005 (black) IP66

Protection Rating (IP as per IEC/EN 60529) Insulation Class

Zone Suitability Description ZONE Usable

13

0

I

Gas 1

X

2

X

20

External Size (mm)

Max power dissipation allowed (W)

Dust 21 X

22 X

FLP

Certificates

Instructions

RINO-EX SERIES - FLUORESCENT FITTINGS IP66

Watertight lighting fixtures in stainless steel AISI 304 suitable for applications in areas at risk of explosive atmospheres as defined in ATEX Directive 2014/34/UE. The diffuser is in tempered glass. The fixing hooks are in stainless steel AISI 304. The sealing is guaranteed by a reinforced gasket in nonageing elastomer. Complete with corrosion resistant non-loosening terminals and nonsparking lampholder. Complete with internal and external earth connection. See page 22 for table of chemical resistance.

Lighting Fixtures - Stainless Steel/Glass - with symmetrical reflector IP66

Accessories

820001

Code 820131EX 820231EX 820331EX 820132EX 820232EX 820332EX 820111EX 820211EX 820311EX

Lamp Wattage

Switch Gear

Code

820000

820006

Description

1 x 18W Electronic 820001 Pair of Stainless Steel AISI 304 Hooks 1 x 36W Electronic 820000 Pair of Stainless Steel AISI 304 Swiveling Supports 1 x 58W Electronic 820006 Pair of Stainless Steel AISI 304 Pipe Mounting 2 x 18W Electronic Collars (Ø60mm max.) 2 x 36W Electronic 2 x 58W Electronic (1+1) x 18W Emergency (1+1) x 36W Emergency (1+1) x 58W Emergency Equipment included: Pair of hooks in AISI 304 steel for pendant installation. Fluorescent tubes are not included.

Features

ATEX Directive 2014/34/EU

Conformity to standards

Dimensions

EN 60079-0:2009 EN 60079-15:2010 EN 60079-31:2009 Directive 2014/35/EU EN 60598-1:2008 + A11: 2009 EN 60598-2-1:1989 II 3G 2D

Atex Execution

Ex nA IIC T4 Gc Ex tb IIIC T 85 °C Db Ex nR IIC T6 Gc Ex tb IIIC T 70 °C Db (emergency) Body Material

Stainless steel AISI 304

Diffuser Material

Tempered glass

Protection Rating (IP as per IEC/EN 60529)

IP66

Rated Voltage

230V

Frequency

50-60Hz

Lampholder Type

G13 T8

Max Cable Section

2.5mm2

Emergency battery lifetime

1hr (Emergency Versions)

Insulation Class

I

Operating Temperature

-20°C - +40°C (2 Tube) -20°C - +50°C (1 Tube)

Wattage

Certificates

Zone Suitability Description ZONE Usable

18W 36-58W

0

Gas 1

2

X

20

Dust 21 X

A B (mm) (mm) 690 480 1300 1090

Instructions

22 X

FLP

14

RINO-EX SERIES - BULKHEAD FITTINGS IP65

Watertight bulkhead lamps in aluminium suitable for applications in areas at risk of explosive atmospheres as defined in ATEX Directive 2014/34/UE. The body of the bulkhead lamp is treated with ecological anti-corrosion passivation with fluoro-zirconium and finished with hot polymerized scratch-resistant nontoxic polyester painting. The diffuser is in prismatic tempered glass. The protection cage is attached to the body by means of stainless steel screws, the sealing is guaranteed by a gasket in non-ageing elastomer. Pre-configured for entry through an M20 cable gland. Complete with internal and external earth screw. Lamps to be ordered separately. See page 22 for table of chemical resistance.

Round Bulkhead Lamps - In aluminium alloy with steel protective cage c/w cable gland IP65

Oval Bulkhead Lamps - In aluminium alloy with steel protective cage c/w cable gland IP65

Code 831172EX

Lamp Power

Dimensions (mm)

28W max.

Code 830072EX

226 x 130

Lamp Power

Dimensions (mm)

28W max.

200 x 182

Dimensions

Features

Conformity to standards

ATEX Directive 2014/34/EU

EN 60079-0:2012 + A11:2013 EN 60079-15:2010 EN 60079-31:2014

Directive 2014/35/EU

EN 60598-1:2008 + A11: 2009 EN 60598-2-1:1989

Atex Execution

II 3G 2D

Ex nA IIC T 145/160/190 °C (T3) Gc Ex tb IIIC T 75/85/90 °C Db

Body Material

Aluminium Alloy

Surface Treatment

Passivation with fluoro-zirconium

Painting

Hot polymerized non-toxic polyester

Diffuser Material

Prismatic Tempered Glass

Protective Cage Material

Painted tropicalized steel wire

Colour

RAL 7035 (light grey) Back box;

Protection Rating (IP as per IEC/EN 60529) Rated Voltage Frequency

RAL 2011 (deep orange) Protection Cage IP65

500V

50-60Hz

Max Cable Section

2.5mm2

Lampholder Type

E27 type in porcelain

Operating Temperature

-20°C - +40°C

Wattage

I

Insulation Class

28W

Zone Suitability Description ZONE Usable

15

0

Gas 1

2

X

20

Dust 21 X

22 X

FLP

A B C D E F (mm) (mm) (mm) (mm) (mm) (mm) 226

Certificates

122

105

210

130

Instructions

42

ALARM-EX SERIES - SIRENS & BELLS

Sirens and bells in aluminium alloy for continuous operation, suitable for applications in areas at risk of explosive atmospheres as defined in ATEX Directive 2014/34/UE. The internal terminal board is in self-extinguishing thermosetting insulating material. Screws for internal and external earth

connection. Back box and cover are treated with ecological anti-corrosion passivation with fluoro-zirconium and finished with hot polymerized scratchresistant non-toxic polyester painting. The gasket in non-ageing elastomer and the stainless steel screws guarantee the watertight sealing with IP66 protection rating for the sirens and IP55 for the bells. See page 22 for table of chemical resistance.

Bell - In aluminium alloy, with steel drum c/w cable gland IP55

Siren - In aluminium alloy, with vibrating membrane c/w cable gland IP66

900449

900473EX

Code 900473EX Accessories Code 900449

Sound Level

Starting Power

105dB

Running Power

60VA

Code 900273EX

25VA

Sound Level

101dB

Starting Power

Running Power

13VA

11VA

Description

Directional Horn Ø112 x 238mm

Dimensions

Features

Conformity to standards

ATEX Directive 2014/34/EU EN 60079-0:2012 + A11:2013 EN 60079-15:2010 EN 60079-31:2014 Directive 2014/35/EU EN 62080:2009

Atex Execution

II 3G 2D/3D (Sirens) II 3G Ex nA IIC T3 Gc II 2D Ex tb IIIC T 65 °C Db (Bells) II 3G Ex nA IIC T3 Gc II 3D Ex tc IIIB T 65 °C Dc

Material

Aluminium Alloy

Siren Drum Material

Painted Galvanised Steel

Colour

RAL 9005 (black) - Box / RAL 2011 (deep orange) - Cover

Protection rating (IP as per IEC/EN 60529)

IP66 (Sirens) IP55 (Bells)

Rated Voltage

230VAC

Frequency

50-60Hz

Insulation Class

I

Operating Temperature

-20°C - +40°C

Siren Zone Suitability Description ZONE Usable

Bell Zone Suitability 0

Gas 1

2

X

20

Dust 21 X

Description

22

ZONE Usable

X

FLP

0

Gas 1

2

X

20

Dust 21

22 X

16

UNI-EX SERIES ADAPTORS IP67

Adaptors in galvanised steel with male threading PG or Gas and female threading to connect devices of different standards. The products are suitable for applications in areas at risk of explosive atmospheres as defined in ATEX Directive 2014/34/EU. See page 22 for table of chemical resistance.

Adaptors - in Galvanised Steel for Conduit/Box Coupling

FLP

Code Gas/Metric 580360EX 580361EX 580364EX 580365EX PG/Metric 580394EX 580395EX 580396EX

Features

Conformity to standards

Male Thread

Female Thread

3/8" Gas 1/2" Gas 3/4" Gas 1" Gas

M16 x 1.5 M20 x 1.5 M25 x 1.5 M32 x 1.5

PG21 PG29 PG36

M25 x 1.5 M32 x 1.5 M40 x 1.5

ATEX Directive 2014/34/EU

EN 60079-0:2012 + A11:2013 EN 60079-7:2007

EN 60079-31:2009

Atex Execution

II 2G 2D

Ex d IIC, Ex e IIC, Ex tb IIIC

Body Material

Galvanised steel / Hot polymerized non-toxic polyester IP67

Protection Rating (IP as per IEC/EN 60529) Operating Temperature

Zone Suitability Description ZONE Usable

0

-40°C - +150°C

Gas 1

X

2

X

20

Dust 21 X

22 X

Certificates

Instructions

RINO SERIES - MARINE FLUORESCENT FITTINGS IP66

Lighting Fixtures - Painted Stainless Steel with Opaline Polycarbonate Diffuser IP66

Equipment Included: 2 x Terminal Blocks + 2 x M20 Nickel Plated Brass Cable Glands + Kit for Ceiling Fixing

Features

Conformity to standards Material Painting Diffuser Material Protection Rating (IP as per IEC/EN 60529) Resistance to impacts (IK rating as per IEC/EN 62262) Lampholder Rated Voltage Frequency Emergency battery lifetime Insulation Class Operating Temperature

17

IEC/EN 60598-1 IEC/EN 60598-2-1 Stainless steel AISI 316L Non-toxic polyester resistant to atmospherical agents and UV rays Polycarbonate IP66 IK09 G13 T8 230V 0-50-60Hz (electronic) 1hr I -15°C - +50°C

Code 878132 878232 878111 878211

Switch Gear

Electronic Electronic Emergency Emergency

Robust Thanks to the total absence of welded joints

Permanent Fixing Thanks to the fixing pins and preassembled antivibration systems

LIT FLP

Lamp Wattage

2 x 18W 2 x 36W (1 + 1) x 18W (1 + 1) x 36W

Long Life Thanks to the diffuser in polycarbonate, unbreakable, with V2 self-extinguishing grade, anti yellowing, stabilized against UV rays

TUNNEL54 SERIES - LED LIGHTING IP66

The TUNNEL54 LED range is the new and complete system of lighting fixtures for lighting entrances and central parts of the tunnels. They have great installation flexibility thanks to the new range of accessories for mounting on cable channel with different heights or directly on the wall or ceiling. See page 22 for table of chemical resistance.

Note: special configurations and dimmable power supply upon request.

Features

Conformity to standards

Body Material Diffuser Material Protection Rating (IEC/EN 60529) Colour Resistance to impacts (IK rating as per IEC/EN 62262) Rated Voltage Rated Frequency Max Cable Section Insulation Class Colour Temperature Colour Rendering Index Inlet Cable Length Operating Temperature

LED Tunnel Lighting Fixtures Code Power Lumen Optics 4000 Symmetrical 154000 35W 70W 8000 Symmetrical 154020 12000 Symmetrical 154030 110W 55W 6000 20° Asymmetrical 154110 12000 20° Asymmetrical 154130 110W 55W 6000 45° Asymmetrical 154210 12000 45° Asymmetrical 154230 110W 8000 60° Asymmetrical 155420 80W 160W 16000 60° Asymmetrical 155440 24000 60° Asymmetrical 155460 240W 320W 32000 60° Asymmetrical 155470 40000 60° Asymmetrical 155480 400W 480W 48000 60° Asymmetrical 155490

Illustration

Pair of Supports - in stainless steel for

rapid fixing of LED tunnel lighting fixtures to cable channel

Code 151910 151911 151912 151913 151914 151915

Channel Size (mm)

100 x 75 200 x 75 300 x 75 100 x 100 200 x 100 300 x 100

IEC/EN 60598-1 IEC/EN 60958-2-1; CEI 34-23 EN 62471 EN 55015 EN 62031 UNI 11356 Anodized aluminium alloy Tempered glass IP66 RAL 9005 (Black) IK10 230V 50-60Hz 2.5mm2 II 5000k 70 16A 2P+ IP66 1.5m -25°C - +45°C

The only complete solution for tunnel lighting systems.

Dimensions

Code No. LED 4 154000 6 154110, 154210, 155420 8 154020 154030, 154130, 154230, 155440 12 18 155460 24 155470 30 155480 36 155490

A (mm) 250 300 400 500 670 870 1130 1270

LIT TEC

18

RINO SERIES - Lighting Fixtures IP66

The range of RINO lighting fixtures is manufactured according to the highest quality standards guaranteeing reliability and best performance. The body is cold-drawn in a single piece to ensure corrosion resistance & robustness. RINO series light fittings also deliver high photometric performance. See page 22 for table of chemical resistance.

Stainless Steel/Polycarbonate - c/w Aluminium Symmetrical Reflector IP66

Stainless Steel/Glass - c/w White Reflector IP66

Code 822131 822231 822331 822132 822232 822332 822211

Switchgear

Lamp Wattage

1 x 18W 1 x 36W 1 x 58W 2 x 18W 2 x 36W 2 x 58W 1 + 1 x 36W

Electronic Electronic Electronic Electronic Electronic Electronic Emergency

Features

IEC/EN 60598-1

Conformity to standards

IEC/EN 60598-2-1 Body Material

Stainless steel AISI 316L

Diffuser Material

Tempered Glass / Polycarbonate Fluorescent

Protection Rating (IP as per IEC/EN

IP66

60529) Resistance to impacts (IK rating as

IK09

Code 825132 825232 825332 825111 825211 825311

Switchgear Electronic Electronic Electronic Emergency Emergency Emergency

Lamp Wattage 2 x 18W 2 x 36W 2 x 58W 1 + 1 x 18W 1 + 1 x 36W 1 + 1 x 58W

No welded joints means no oxidation. The non-deformable structure makes RINO suitable to be installed even when vibrations are present.

per IEC/EN 62262) Lampholder

G13 T8

Rated Voltage

230V

Frequency

0-50-60Hz (electronic)

Max Cable Section

2.5mm2

Emergency Battery Lifetime

1hr

Insulation Class

I

Operating Temperature

-25°C - +50°C

The special reinforced gasket guarantees the IP66 protection rating in all the ranges.

Dimensions

Lighting Fixture Type 18W T8 36 T8 58W T8

19

The ultra-bright aluminium reflector ensures optimum efficacy of the luminous flux and therefore an extremely uniform distribution.

A (mm) B (mm) 690 1300 1600

480 1090 1395

TEC LIT

NAVE SERIES - MARINE PRODUCTS IP66

NAVE series is a range of products for connection, junction and lighting that are in compliance with UNAV standards used in specific applications for ships and ferry boats. The special materials used for enclosure and internal components ensure quality and long-term durability. See page 22 for table of chemical resistance.

Bell UNAV 1384 - In Painted Brass with UNAV 1948 Cable Gland

Sirens UNAV 1382 - In Painted Brass with UNAV 1948 Cable Gland

900548 900573

Code 900375

Rated Voltage 230VAC

Bell Ø (mm) 105

1m Sound Level

101dB

Power

Code

13VA Starting

900573

11VA Running

Rated Voltage 230VAC

Duty Cycle: 4 Hours On, 1 Hour Off

Accessories

Switches UNAV 2162 - In Painted Brass with UNAV 1948 Cable Glands

900548

Code

232628

10A

2 (Top)

831289

100W

2

2 (Top)

Code 831727

Description

Protection rating (IP as per IEC/EN 60529)

IP66

Operating Temperature

Non Ageing Thanks to the high quality materials

Lampholder Type E27

LIT Size (mm) 295 x 170 x 127

Accessories

2 (Top)

UNAV unification tables

Insulation Class

Max Lamp Power

Code

Conformity to standards

Colour

831727

831289

1

Material

25VA Running

Bulkhead UNAV 2135 - In Painted Brass with Glass Diffuser & UNAV 1948 Cable Gland

Cable Glands

Features

60VA Starting

Directional Horn Ø112 x 238mm

Poles

2

107/105dB

Power

Description

TEC Rated Code Current One-Way Switches 10A 232626 10A 232627 Two-Way Switches

1m Sound Level

Protective Cage in Stainless Steel

Painted polished brass

RAL7042 (Marine Grey) I

-40°C - +70°C

IP66 Guaranteed Thanks to the external mounting points

TEC ALL

Complete Thanks to the included terminals

20

IP DEGREE OF PROTECTION OF ENCLOSURES

The standard IEC 60529 describes a system of IP codes for classifying the degrees of protection provided by enclosures against access to hazardous parts and protection of equipment against the penetration of solid foreign objects or the ingress of water.

Symbol: IP - 1st digit Protection against penetration of solid foreign bodies Ø12mm

Number Protected Against:

1

2

Penetration of solid Penetration of solid foreign bodies larger foreign bodies larger than 50mm (hands). than 12mm (fingers).

Ø1mm

Ø2.5mm

Ø50mm

3

4

Penetration of solid Penetration of solid foreign bodies larger than foreign bodies larger 2.5mm (tools, cables). than 1mm (wires).

Symbol: IP - 2nd digit Protection against penetration of liquids

1

Protected Against:

The vertical fall of water drops.

Number

5

Protected Against:

2

The fall of water drops at a maximum angle of 15° compared to the vertical position.

Harmful dust deposits Totally protected affecting good against dust. operation.

3

4

Falling rain with a maximum angle of 60° compared to the vertical position.

Water splashes coming from all directions.

7

8

6

Jets of water coming from all directions.

6

60°

15°

Number

5

Effects of temporary immersion Effects of continuous immersion inside water under defined inside water under defined duration and pressure conditions. pressure conditions.

Water projections similar to sea waves.

DEGREE OF PROTECTION AGAINST IMPACTS IK

The standard IEC-EN 50102 defines a coding system, IK code, to indicate the degrees of protection provided by enclosures for electrical equipment against external mechanical impacts.

Number Description

21

06

Resistant to impacts with an energy up to 1.00 J

07

Resistant to impacts with an energy up to 2.00 J

1.7kg

08

Resistant to impacts with an energy up to 5.00 J

04

250mm

250mm

175mm

110mm

0.5kg

03

Resistant to impacts with an energy up to 0.350 J

0.2kg

0.2kg

05

Resistant to impacts with an energy up to 0.500 J

Resistant to impacts with an energy up to 0.700 J 400mm

0.5kg

02

Resistant to impacts with an energy up to 0.200 J

0.2kg

200mm

200mm

Description

01

Resistant to impacts with an energy up to 0.150 J

0.2kg

295mm

Number

0.2kg

400mm

IK00 = No Protection

70mm

Symbol: IK

5kg

09

Resistant to impacts with an energy up to 10.00 J

5kg

10

Resistant to impacts with an energy up to 20.00 J

RESISTANCE TO CHEMICAL AGENTS & ATMOSPHERIC CONDITIONS

The resistance of a material to the erosive and ageing action of chemicals or atmospheric agents is not a direct relationship, but depends on the conditions of installation, temperature, chemical agent concentration and on the other interactions that different substances present inside the atmosphere can have on the concerned product. Material chemical resistance tables, resulting from lab tests, represent a useful instrument, but provide indications only, as universal installation conditions cannot be established. To make reading easier, and taking what is stated above into account, we summarized the material resistance levels in 3 values: high resistance (arrow up), partial resistance (arrow to the right) and low resistance (arrow down).

Thermoplastic Material

Acids Saline Concentrated Diluted Atmospheres

Water

Mineral

Oils Vegetable

Animal

Oils

Chemical Bases Concentrated Diluted

Synthetic

Thermosetting Material (GRP)

Acids Saline Atmospheres Concentrated Diluted

Water

Mineral

Oils Vegetable

Aluminium Water

Mineral

Brass Water

Mineral

Steel Water

Mineral

Legend:

Animal

Oils

Animal

Oils

Synthetic

Animal

Oils

Synthetic

High Resistance

Animal

Oils

Synthetic

Ammonia

Oxidizers

Ammonia

Oxidizers

Chemical Bases Concentrated Diluted

Synthetic

Partial Resistance

Oxidizers

Chemical Bases Concentrated Diluted

Acids Saline Atmospheres Concentrated Diluted Oils Vegetable

Ammonia

Chemical Bases Concentrated Diluted

Acids Saline Atmospheres Concentrated Diluted Oils Vegetable

Oxidizers

Chemical Bases Concentrated Diluted

Acids Saline Atmospheres Concentrated Diluted

Oils Vegetable

Ammonia

Ammonia

Oxidizers

Alcohol Inorganic Salts

Alcohol Inorganic Salts

Alcohol Inorganic Salts

Alcohol Inorganic Salts

Alcohol Inorganic Salts

Solvents Acetone Perchloroethylene

Benzene

Gasoline

U.V. Rays

Detergents

Solvents Acetone Perchloroethylene

Benzene

Gasoline

U.V. Rays

Detergents

Solvents Acetone Perchloroethylene

Benzene

Gasoline

U.V. Rays

Detergents

Solvents Acetone Perchloroethylene

Benzene

Gasoline

U.V. Rays

Detergents

Solvents Acetone Perchloroethylene

Benzene

Gasoline

U.V. Rays

Detergents

Low Resistance

22

AC/DC SFC PALA

1st Edition September 2016

ACDC SFC PALAZOLLI.pdf

Page 2 of 24. In 1904 Palazzoli began its activity in Brescia when electrical energy was first used in the industry. The company is specialized in manufacturing electrical appliances with safety features that are. protected and watertight, for industrial, marine, civil, agricultural and OEM applications. The offer of PALAZZOLI ...

5MB Sizes 52 Downloads 458 Views

Recommend Documents

ACDC SFC FANS.pdf
433.92MHz). 16'' 3 speed floor standing fan. 16'' 3 speed floor standing fan with remote control & 8 hour timer. Code. Floor Standing Fans. Description. CH-1686.

ACDC SFC GEWCH.pdf
There was a problem previewing this document. Retrying... Download. Connect more apps... Try one of the apps below to open or edit this item. ACDC SFC ...

ACDC SFC TERASAKI.pdf
Advanced protection from live parts. • Up to 40kA in unbelievably. small 160A frame size. • Field addable accessories. • IP54 or IP65 varible depth handles. • Symmetrical door cut-out patterns. • Adjustable or fixed settings. Brilliant. Fea

ACDC SFC DRIVES.pdf
Standard. Option: MR4 - MR9. -. Option. 2 x 0-10V /. 0(4)-20mA. 1 x 0-10V /. 0(4)-20mA. 6. -. +SBF3: 2 x NO/ NC, 1. x NO standard +SBF4: 2 x NO/NC, Therm. 3 Slots. RS 485 and Ethernet. Standard. Standard. Option OPT-E3/5-V. Option OPT-E7-V. Option OP

ACDC SFC GEWCH.pdf
pushbutton for bells. 1 x 1M 1P 16A. pushbutton and Shuttle ... FTP sockets. Code. Data. Telephone Socket ... ACDC SFC GEWCH.pdf. ACDC SFC GEWCH.pdf.

ACDC SFC FLAMEPROOF.pdf
D. B. O. التي تحصر القوس AB. #. Whoops! There was a problem loading this page. Retrying... Whoops! There was a problem loading this page. Retrying... ACDC SFC FLAMEPROOF.pdf. ACDC SFC FLAMEPROOF.pdf. Open. Extract. Open with. Sign In. Ma

ACDC SFC ENMAN.pdf
1 analysis software (PqaSoft). • 1 instruction manual (English, Italian & Spanish). Compulsory separate insurance is required. Information. PQA700-R. PQA700- ...

ACDC SFC TOOLS.pdf
Low battery indication. • DAR / PI Insulation mode. • Backlit LCD display. • Bargraph display. • Peak measurement. • Auto ranging. • Max/Min data hold. • Auto power off. • Low battery indication. • USB interface. (Windows OS). • R

ACDC SFC DECORATIVE.pdf
Page 2 of 28. Code. Code. Code. Code. ALD1105-L0077. MD2140529-10. RQ1107E-R8088. MD2140526-6. ALD1105-L0075. MD2140525-8+4. SST99005.

ACDC SFC 13MM.pdf
Page 2 of 4. 2. 4.5kA Circuit Breakers C Curve. 1P C Curve 1P+N C Curve 3P D Curve. C Curve. 4P C Curve. 2P D Curve 4P C Curve. D Curve. 1 Pole Code. 1M wide Amps. Amps. 2 Pole Code. 2M wide. 3 Pole Code. 3M wide. 1A. 2A. 5A. 10A. 15A. 20A. 25A. 32A.

ACDC SFC AUT.pdf
Metal protection. cover for lens. • Waterproof. housing. *Add voltage to code: 230VAC (86-265VAC) or DC (24VDC), eg. XHD-300-019-230VAC. Traffic Lights Traffic Light Set. Code Colour Type. • Excludes housing • Lumen >400mcd • Supply Volts: 23

ACDC SFC RHE.pdf
SC410/SC411: Opto-Electronic Control unit. SC501: Temperature Control Module. SC510/SC511: Thermistor Motor Protection Module. SC610/SC611: Flip-Flop Relay with/without Memory. SC900: Power Supply Module. CC120: Totalising Counter. SC700: Multi-Funct

ACDC SFC AUTOMATION.pdf
Controller (PLC). 17-23. Inductive Proximity. Switches. 44. Long Range Photo-. electric Sensor Kits. 53. Safety Control, Relays. & Connector Boxes. 55-56. Actuator Boxes, Cables & Connectors. 32, 37 & 38. Mark, Luminescence. & Colour Sensors. 5. Swit

ACDC SFC CAMPING.pdf
Whoops! There was a problem loading more pages. Retrying... Whoops! There was a problem previewing this document. Retrying... Download. Connect more apps... Try one of the apps below to open or edit this item. ACDC SFC CAMPING.pdf. ACDC SFC CAMPING.p

ACDC SFC FANS.pdf
separately. Order fan hook. separately. E27. 4 / 42" (1066mm). Aluminium / Wood. Chain. M42027-XY-1L. M42027-Glass. 1 FAN. CEILING FANS. Page 2 of 24 ...

ACDC SFC SP.pdf
210kg / 5 bags. • Suitable for residential pools and fish ponds. • Maximum working pressure: 200kPa. • Easy to use multi-port valve allows easy selection. of valve / filter operations. • Valve / filter operations: filter, backwash, rinse,. wa

ACDC SFC GAVE.pdf
KVA @. 400V AC21. 44kVA. 55kVA. 69kVA. 87kVA. 111kVA. 139kVA. 173kVA. 28kVA. 44kVA. 44kVA. 55kVA. 69kVA. 87kVA. 111kVA. 139kVA. 173kVA. 28kVA. 44kVA. 44kVA. 55kVA. 69kVA. 87kVA. 111kVA. 139kVA. 173kVA. DC Voltage Rated Current. Output Input. Rated Po

ACDC SFC 3M.pdf
High dielectric strength, conformmable and provides good mechanical protection with minimum bulk. 3M-44881 Premium grade ... Pressure sensitive rubber adhesive. • Abrasion and ... Designed for use in Phase identification, colour coding of motor lea

ACDC SFC TC.pdf
Star Delta Starters. Borehole Pump Starters. Borehole Pump Controls. Plastic Bezel Ø22mm Control Devices. RB2 Pushbuttons & Pilot Lights Ø22mm. Pushbuttons & Pilot Lights (Various Sizes). Legend Plates / Lamps & LED's. Pushbutton Stations. Busbar S

ACDC SFC STANDBY.pdf
There was a problem previewing this document. Retrying... Download. Connect more apps... Try one of the apps below to open or edit this item. ACDC SFC ...

ACDC SFC GEWISS.pdf
125A. 125A. -. -. Code Description. GW44704. GW44720. GW44671. GEW 2. EMERGENCY BREAK-GLASS STATIONS. Page 3 of 44. ACDC SFC GEWISS.pdf.

ACDC SFC SOLAR.pdf
Accessories. Battery Type. Battery Life. Lamp Power/Lumen. Accessories. Lead Acid. Up to 16 hrs full charge. 2 x 2W / 160lm. 10in1 USB Phone Charger, Hair.

ACDC SFC 3X3.pdf
15A South African to. multi-adaptor. 2 Pin Euro / American to. British, Australian, Euro or. American. 13A British to Multi-adaptors. & to South African. Input multi-plug: can be configured as British, American,. Australian and Euro. Output: multi-pl

ACDC SFC WIR ACC.pdf
Insulated busbar 1 phase 63Amps, 1000mm, 56 poles. Insulated busbar 2 phase 63Amps, 1000mm, 56 poles. Insulated busbar 3 phase 63Amps, 1000mm, ...