AHEAD​ ​Blockcoat​ ​PUTTY​ ​E

2-component​ ​epoxy​ ​putty For​ ​electrical​ ​insulation​ ​of​ ​PDR​ ​connections​ ​and​ ​intersections Description AHEAD​ ​Blockcoat​ ​PUTTY​ ​E​ ​consists​ ​of​ ​2​ ​components​ ​on​ ​the​ ​basis​ ​of​ ​low-viscous,​ ​solvent-free​ ​epoxy resins. Areas​ ​of​ ​application Non-shrinking​ ​putty​ ​for​ ​the​ ​leveling​ ​of​ ​concrete,​ ​and​ ​filling​ ​in​ ​of​ ​casting​ ​holes,​ ​gravel​ ​nests,​ ​etc. Also​ ​suitable​ ​for​ ​gluing​ ​steel​ ​and​ ​wooden​ ​foundations.​ ​After​ ​complete​ ​curing,​ ​AHEAD​ ​Blockcoat​ ​PUTTY​ ​E is​ ​resistant​ ​to​ ​the​ ​most​ ​frequent​ ​chemicals​ ​and​ ​solvents.​ ​Excellent​ ​permanent​ ​adhesion​ ​to​ ​steel,​ ​concrete and​ ​wooden​ ​foundations​ ​is​ ​provided​ ​when​ ​the​ ​requirements​ ​mentioned​ ​under​ ​preparations​ ​are​ ​followed. Preparations AHEAD​ ​Blockcoat​ ​PUTTY​ ​E​ ​adheres​ ​excellently​ ​to​ ​cement-bound​ ​substrate.​ ​These​ ​substrates​ ​must​ ​be clean,​ ​dry​ ​and​ ​at​ ​least​ ​28​ ​days​ ​old.​ ​No​ ​after-treatment​ ​with​ ​cement​ ​powder​ ​must​ ​be​ ​given​ ​and​ ​there​ ​must be​ ​no​ ​layer​ ​of​ ​cement-glue.​ ​Sand-cement​ ​finishing​ ​layers​ ​must​ ​adhere​ ​well​ ​to​ ​the​ ​substrate.​ ​Steel substrates​ ​must​ ​be​ ​fully​ ​cleaned​ ​(according​ ​to​ ​Normalization​ ​Sheet​ ​SA​ ​2,5.) Mixing​ ​ratio

69​ ​parts​ ​by​ ​weight​ ​of​ ​component​ ​A 31​ ​parts​ ​by​ ​weight​ ​of​ ​component​ ​B

It​ ​is​ ​recommended​ ​first​ ​to​ ​stir​ ​component​ ​A​ ​thoroughly​ ​before​ ​adding​ ​component​ ​B. Mix​ ​thoroughly.​ ​Then​ ​put​ ​the​ ​mixture​ ​in​ ​a​ ​clean​ ​drum​ ​and​ ​mix​ ​again.​ ​The​ ​mixing​ ​is​ ​essential! To​ ​avoid​ ​errors,​ ​the​ ​two​ ​components​ ​of​ ​AHEAD​ ​Blockcoat​ ​PUTTY​ ​E​ ​have​ ​contrasting​ ​colours.​ ​This​ ​makes a​ ​check​ ​on​ ​the​ ​mixture​ ​possible.​ ​After​ ​mixing,​ ​the​ ​mixture​ ​must​ ​have​ ​a​ ​homogeneous​ ​colour. Application The​ ​minimum​ ​layer​ ​thickness​ ​in​ ​which​ ​AHEAD​ ​Blockcoat​ ​PUTTY​ ​E​ ​can​ ​be​ ​applied,​ ​is​ ​approx.​ ​200​ ​micron. It​ ​is​ ​possible​ ​to​ ​apply​ ​AHEAD​ ​Blockcoat​ ​PUTTY​ ​E​ ​in​ ​one​ ​single​ ​layer,​ ​up​ ​to​ ​a​ ​maximum​ ​of​ ​10​ ​mm. Pot​ ​life As​ ​a​ ​mixture 10°C​ ​-​ ​approx.​ ​30​ ​minutes 20°C​ ​-​ ​approx.​ ​20​ ​minutes 30°C​ ​-​ ​approx.​ ​15​ ​minutes

HS​ ​export​ ​code:​ ​3208​ ​9091

Blockcoat​ ​PUTTY​ ​E,​ ​Rev​ ​1​ ​May​ ​-​ ​2015 Page​ ​1​ ​of​ ​2

Curing AHEAD​ ​Blockcoat​ ​PUTTY​ ​E​ ​cures​ ​in​ ​any​ ​layer​ ​thickness. Curing​ ​time:​ ​dust​ ​dry​ ​approx.​ ​2​ ​hours ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​ ​10°C​ ​approx.​ ​48​ ​hours ​ ​ ​ ​20°C​ ​approx.​ ​24​ ​hours Cleaning​ ​and​ ​storage Cleaning​ ​with​ ​a​ ​water-soluble​ ​cleansing​ ​agent​ ​before​ ​the​ ​curing​ ​process​ ​starts. Store​ ​dry.​ ​Keep​ ​containers​ ​tightly​ ​closed.​ ​Preferably​ ​at​ ​temperature​ ​of​ ​5-30​ ​°C. Technical​ ​data Specific​ ​gravity Bending​ ​tensile​ ​strength Pressure​ ​strength E-module Resistance​ ​to​ ​shock Resistance​ ​to​ ​impact Shrinkage Hardness Linear​ ​coeff.​ ​of​ ​expansion Packing​ ​size

1,1​ ​kg/dm​3 approx.​ ​35​ ​MPa approx.​ ​80​ ​MPa approx.​ ​8000​ ​MPa very​ ​good very​ ​good none 82​ ​Shore​ ​D 91​ ​x​ ​10​-6​ ​K​-1

A​ ​component​ ​0.69​ ​kg B​ ​component​ ​0.31​ ​kg

Safety Classified​ ​according​ ​to​ ​CLP​ ​(EC)​ ​No.​ ​1272/2008 Safety​ ​datasheet​ ​is​ ​provided​ ​for​ ​this​ ​product.

HS​ ​export​ ​code:​ ​3208​ ​9091

Blockcoat​ ​PUTTY​ ​E,​ ​Rev​ ​1​ ​May​ ​-​ ​2015 Page​ ​2​ ​of​ ​2

AHEAD Blockcoat PUTTY E

AHEAD Blockcoat PUTTY E consists of 2 components on the basis of low-viscous, solvent-free epoxy resins. Areas of ... Cleaning and storage ... Technical data.

247KB Sizes 2 Downloads 168 Views

Recommend Documents

AHEAD Binder E/N
Areas of application. Transparent binder for different uses, such as applying over ZEBRA PDR, on epoxy mortars and synthetic floors, on sufficiently aged and dry substrates. The substrate on which ... Second / continuous layers application must cure

Open putty and type remote hostname - GitHub
(here I put simply hostname ) and then click Save button. From now on your connection to remote host with tunnel is saved and can be reused anytime you open ...

AHEAD Multiprimer
AHEAD Multiprimer is mainly for use on soffits and walls, concrete subbases without rolling cargoes. Preparations. Concrete. The concrete subbase to be treated ...

Industry Dynamics and the Minimum Wage: A Putty ...
We develop a model of industry dynamics based on putty-clay technology that is consistent with ... Federal Reserve Bank of Chicago, the Graduate Institute Geneva, and the University of Michigan. Thanks to Jess .... results complement earlier research

run ahead of God
learn that when we try to help or hurry God, we can make a mess of things. ..... or call USA 1-800-772-8888 • AUSTRALIA +61 3 9762 6613 • CANADA ...

run ahead of God
Open your Bible and read Genesis 16 to get the flow of the story. If you wish, .... plan and the highbrow society ladies would have nodded in support, God disapproved. .... or call USA 1-800-772-8888 • AUSTRALIA +61 3 9762 6613 • CANADA ...

AHEAD Multiprimer Floor
Description. AHEAD Multiprimer Floor is a primer, based on a mild, water-based epoxy resin with high penetration into concrete and other mineralic substrates.

Secure surfing using Ubuntu Server, Putty, Firefox ... - Knightwise.com
connect OUT over that port from the local network you are on at the moment). - Setup and enable a dyndns service on your server : http://revision3.com/systm/dyndns/ ... If you are (for example) in a hotspot, we are going to check what your ...

AHEAD EC Levelling Layer
AHEAD EC Levelling Layer will, when applied on Zebra Anode, act as an alkaline ... 2-3 hours. No. of coats required on ZEBRA normally one coat at 1 mm ...

Three Steps Ahead
Three Steps Ahead. Yuval Heller. Nuffield College & Department of Economics, Oxford. January 2014. Yuval Heller (Oxford). Three Steps Ahead. 1 / 23 ...

Day-Ahead Daily Market Watch
Feb 22, 2018 - 100. 120. 140. 160. NP15. SP15. ZP26. Price ($/MWh). 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24. IFM Default LAP LMPs.

AHEAD Ax/ECH
The areas to be treated must be free from all unsound materials. Smooth surfaces should be roughened. ... Avoid storage at temperatures exceeding 20°C. Shelf life of 12 months at 20°C. Technical data. Standard color. Grey. Mixed Density.

ahead multiprimer floor
Carbon dioxide permeability sd >50 m. EN 1504-2:2004. Crack bridging ability. NPD. EN 1504-2:2004. The performance of the product conforms with the declared performance. This declaration of performance is issued under the sole responsibility of the m

AHEAD Multiprimer Floor
Areas of application. Water-based, low on emissions (VOC), 2-component primer for adhesion promotion on ZEBRA. Conductive paint for subsequent AHEAD Levelling Layer or AHEAD Ax/ECH application. For floor slabs in combination with quartz sand ... Clea

Three Steps Ahead
Rarely a few agents experiment with a new type (“mutants”). Objective: characterize stable states of the population in the long ... Horizon - the number of remaining stages. Partial observability of abilities (a la Dekel, Ely, ... Everyone plays

Look-Ahead Processors
domain registers D(b ) and range registers R(b ) as follows: If .... causes the transfer of instructions into the window to ... The operation names shown here will not.

Looking Ahead & Beyond -
A separate 'cost centre' or 'separate 'company account' or Personal Ledger would also be opened in Ahura Support's accounting software to track and manage ...

Three steps ahead - Wiley Online Library
a new mechanism to induce cooperation in the repeated prisoner's dilemma. Keywords. Limited ... the realization of T. We interpret k as the horizon (i.e., number of remaining steps) in which a player with ability .... shall say that a strategy is ear