1. Introduction The Capacitive Proximity Sensor Module is used to detect metal as well as nonmetallic materials such as solids, liquids, plastic, glass, wood and paper. But it is more suitable to be used for detecting the nonmetallic targets. The ability of the sensor to detect the target is determined by the target’s size, dielectric constant and distance from the sensor. The bigger number of dielectric constant, the material will be easier to be detected. The larger the target’s size and the shorter the distance between target and probe, the capacitive coupling will be stronger. The corresponding light indicator will ON when the target is being detected. This sensor consists of knob adjustor which is used to vary its sensitivity of detection materials. Specifications:  Input Voltage : DC 6V to 30V  Output : o Digital (0 or 1 digit)  Output Signal : NPN (Active low)  Sensitivity : Adjustable  LED indicator : Red color

3|Page

2. Wires Definition

Red LED Indicator BLACK BROWN BLUE

Sensitivity Adjustor  Clockwise for increasing material detecting sensitivity.  Anticlockwise for reducing material detecting sensitivity.

Wire

Description

Function

Brown (VCC)

6V~30V

Connect to +6V ~ 30V power supply (Internal testing, it is also compatible with 5V)

Blue (GND)

Ground

Connect to Ground  

Black (Output)

Digital Output (NPN Signal)

Active Low, it is able to connect to the load such as relay, lamp, input microcontroller, input PLC, and etc. The voltage of output signal depends on VCC voltage.

Example: o VCC: 6V  Output: 6V o VCC: 32V  Output: 32V

4|Page

3. Sample Hardware Installation and Sample Source Code Diagram below shows the hardware connection between Capacitive Proximity Sensor Module and microcontroller. For the power supply that is 6V and above, before connecting the Capacitive Proximity Sensor’s output to the microcontroller, remember to put voltage divider (see below diagram) in order to regulate the voltage to 5V which is suitable voltage for majority microcontroller such as Arduino, PIC and etc. Otherwise, it may cause damage on microcontroller due to the high voltage.

5|Page

Diagram below shows the hardware connection between Capacitive Proximity Sensor Module and Arduino UNO. In this example, the 5V is used to activate the sensor so the voltage divider is not need to be connected.

  

Output  Arduino Digital Pin 7 VCC  Arduino +5V GND  Arduino GND

6|Page

To obtain the result, please get the sample source code and burn it into Arduino. After that, open the “Serial Monitor” to see the result.

7|Page

4. Result The example is done between a thick exercise book and a thin white card. The sensor is unable to detect the thin white card, because its capacitive coupling is too weak to be detected by the sensor. The LED is OFF.

8|Page

Next, the thick solid item (exercise book) is used. The sensor is able to detect the item (exercise book) due to its capacitive coupling is strong enough for sensor. The LED is turned ON. Therefore, the size of chosen item should be considered as it will affect the sensitivity of sensor. The solid or thick item is preferred for this sensor.

9|Page

5. Warranty    

Product warranty is valid for 1 month. Warranty only applies to manufacturing defect. Damaged caused by misuse is not covered under warranty. Warranty does not cover shipping cost for both ways.

Prepared by Mybotic 47, Jalan Universiti 1, Taman Universiti, 86400, Parit Raja, Johor Tel: +6016-7170703 / +6018-9510703 URL : www.mybotic.com.my Email : [email protected] [email protected] 10 | P a g e

Capacitive Proximity Sensor Module User's Manual v1.0.pdf

Sign in. Loading… Whoops! There was a problem loading more pages. Retrying... Whoops! There was a problem previewing this document. Retrying.

865KB Sizes 2 Downloads 201 Views

Recommend Documents

MPR121, Proximity Capacitive Touch Sensor ... - Mouser Electronics
increased internal intelligence plus Freescale's second generation ... Power Configuration 2: MPR121 runs from a 2.0V to 3.6V supply. 20. 6. 5. 1. 2. 3 ..... the comparison between the 10-bit electrode filtered data and the 10-bit baseline value.

Compact Proximity sensor Manual.pdf
There was a problem previewing this document. Retrying... Download. Connect more apps... Try one of the apps below to open or edit this item. Compact ...

Soil Moisture Sensor Module User's Manual v1.0.pdf
Soil Moisture Sensor Module User's Manual v1.0.pdf. Soil Moisture Sensor Module User's Manual v1.0.pdf. Open. Extract. Open with. Sign In. Main menu.

Touch Sensor Module User's Manual v1.0.pdf
Page 3 of 7. 3 | P a g e. 1. Introduction. Touch Sensor Module is used to detect human finger touch. It is known as touch switch as well. When human finger touch ...

Water Sensor Module User's Manual v1.0.pdf
There was a problem loading more pages. Retrying... Water Sensor Module User's Manual v1.0.pdf. Water Sensor Module User's Manual v1.0.pdf. Open. Extract.

Sound Sensor Module User's Manual v1.0.pdf
Input Voltage: DC 3.3V to 5V. Output: Digital. Page 3 of 9. Sound Sensor Module User's Manual v1.0.pdf. Sound Sensor Module User's Manual v1.0.pdf. Open.

ACS712 Current Sensor Module (20A) User's Manual v1.0.pdf ...
Measuring current range up to ±20A. Page 3 of 15. ACS712 Current Sensor Module (20A) User's Manual v1.0.pdf. ACS712 Current Sensor Module (20A) User's ...

Water Flow Sensor Module User's Manual v1.0.pdf
Water Flow Sensor Module User's Manual v1.0.pdf. Water Flow Sensor Module User's Manual v1.0.pdf. Open. Extract. Open with. Sign In. Main menu.

DS18B20 Temperature Sensor Module User's Manual v1.0.pdf ...
There was a problem previewing this document. Retrying... Download. Connect more apps... Try one of the apps below to open or edit this item. DS18B20 ...

141215-MP2017-Magnetic-Proximity-Sensor-c4-osmptt.pdf ...
141215-MP2017-Magnetic-Proximity-Sensor-c4-osmptt.pdf. 141215-MP2017-Magnetic-Proximity-Sensor-c4-osmptt.pdf. Open. Extract. Open with. Sign In.

IR Line Tracking Sensor (4 bits) Module User's Manual v1.0.pdf ...
Sensitivity : Adjustable (potentiometer adjustment). Page 3 of 6. IR Line Tracking Sensor (4 bits) Module User's Manual v1.0.pdf. IR Line Tracking Sensor (4 bits) ...

Design module user manual - GitHub
In the design module objects like buildings can be selected. For each case, measures ... Figure 3, parts of the web application for control and visualizing data. 1.

Cheap 220V 100W Ir Infrared Module Body Intelligent Sensor Light ...
Cheap 220V 100W Ir Infrared Module Body Intelligent ... n Sensing Switch Free Shipping & Wholesale Price.pdf. Cheap 220V 100W Ir Infrared Module Body ...

Module I Module II Module III Module IV Module V
THANKS FOR YOUR SUPPORT.MORE FILES DOWNLOAD ... Module VII. Marketing-Importance ,Scope-Creating and Delivering customer value-The marketing.

VABS Manual for Users
9 Jan 2012 - The 3D pointwise displacement/strain/stress distribu- tion within the structure can also be recovered based on the global behavior of the 1D beam analysis. Since most of the theoretical details are presented in pertinent papers and colle

VAMUCH Manual for Users
Mar 1, 2012 - Uses a simplified license mechanism. 6. Has a more detailed manual for end users and a manual for developers. 7. Adopts gfortran as the compiler to create executables for multiple operating systems including. Windows, Linux, and Mac. La

Modular reweighting users manual
mechanical analysis of biased equilibrium data”, Computer physics .... I really hope the script library gets big for the sake of beginners, but advanced simulators ...

MDR2400-EHD User Manual Users Manual Pages twenty ... - FCC ID
Historic AIS. Page 40 Issue 1. 862-015.45 uLink System Manual. Indoor Unit (IU) Rear Panel. Controls,. Indicators and Figure 11 shows all items on the IU Rear Panel. Connectors Table 7 describes the items shown in the illustration. Outdoor Unit DC Po

MDR2400-EHD User Manual Users Manual Pages twenty ... - FCC ID
module mates firmly with the female connector inside the IU. - Secure the Data Interface module to the IU. Slide the IU into the 19" rack and secure to the. 3.

Manual Module MP2310 Yaskawa.pdf
Novela escrita en 1876 por Joseph Henry Shorthouse (1834-1903), que alcanzó ... recording, or other- wise, without the prior written permission of Yaskawa.

Sensor ] ( Sensor
Engine. Base. N303. Enviromental. Database. Agent Interface "\-/301. 71;]. 3 ..... agent architecture and processes usable for the detection and tracking of a ...